Professional Documents
Culture Documents
iriscope
User Manual
irisocamera.com
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
5
4
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
Xpert
Components and setup
(1) camera
bayonet
(3) controller
box
functions
connect
USB
eyepiece
connection
menu
display
picture info
power
front lights switch
selector
battery level
3 - To use the optional AC adaptor, insert the high lintensity red/green LED
battery-like piece in the battery compartment, flashing indicator
light intensity display selected
close the door and pull-up the soft latch to allow switch front lights
plugging the cable (illustrations 3 and 4).
The controller box holds two AA alkaline or
rechargeable batteries. NEVER USE COMMON
CARBON BATTERIES, as they may release dam-
aging acid and void the warranty.
Replace the AA batteries when the battey level
LED turns red. The lighting LEDs within the
eyepiece will automatically turn off when the
voltage is too low.
8 9
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
10 11
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
12 13
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
Microscopic detail
Individual lights for texture and detail
The view on the left is an enlargement of
Individual lights enhance fiber details and
the previous full iris photograph. The
moving shadows give important clues:
sharpness and detail richness results
- tissues raised or sunk get accentuated from applying the "Advanced Techniques"
under a light crossing at a 90º angle described page 16. Those increase
- the bottom of a lesion is better appreci- definition down to a microscopic level.
ated if the light path is aligned and deeply
penetrates into it
Identifying the patient
- some discrete pigmentation spots as well
as textures in the absorption ring are only Prior to recording the irises, it is advis-
perceived under certain light angles able to photograph the patient’s face, as
much to identify the person as to keep a
- milky areas show their underlying details
record of the general appearance. Doing
under sideway lighting
it in a cold manner will prevent a typical
These differences are valuable tools to portrait smile and also register the mood.
study aspects easily set aside for a lack of
Select the “Auto” mode, slightly zoom the
information, and are the reason for shoot-
lens and take the picture of the face.
ing the full six pictures study of every iris
Remember to set the camera back to “P”
mode to photograph the iris.
14 15
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
16 17
irisocamera.com professional iroscopes irisocamera.com professional iroscopes
Maintenance Troubleshooting
IRISO Xpert needs very little care to keep up. The The camera repeatedly fails focusing
LED’s will last over 10,000 hours (i.e. 120,000 five - “Macro” mode may not be selected
minutes photo sessions), the only attentions will be in - zoom out until displaying "1cm - 50cm"
changing batteries and cleaning the eyepiece.
Images do not reach the expected sharpness
- avoid handshake when shooting (use the IRISO
Eyepiece preventive care
Table Stand)
- have the patient stare at a precise point keeping
The rubber eyepiece must be cleaned with alcohol or
both eyes open
a medical desinfectant wipe before or after each use.
- use the self-timer multiple shots technique (p.16)
- refer to all "Advanced Techniques" section (p.16)
At the end of every labored day, it is advised to apply
a siliconized lotion or cream to the rubber eyepiece Lights reflections surrounded by a halo, picture
and leave it all night. An autopart tire gel or lotion will looks “milky”
work well at sealing and enhancing the rubber, and - the front lens is collecting moisture due to cold
will reduce makeup staining. It should be wiped off weather, cold camera or high humidity in the environ-
with alcohol previous to using. ment or coming out of the person’s skin. Proceed
quickly and shortly remove the camera from the face
The rubber eyepiece is user replaceable with care, every so often.
contact IRISO for more information.
Sclera is too bright showing no detail
- the vertical pair of lights is recommended for sclera
- decrease picture brightness with
One light is failing
- check that the eyepiece cable is fully connected to
the controller box
All eyepiece lights are failing
- check the eyepiece connection to the controller box
- check the light high/low power switch is set in a
correct position
- if battery level LED has turned red, put fresh ones in
I do not find my failure in the list
- contact IRISO to find the solution to your problem.
We will diagnose if the failure is due to the camera or
the adaptation, and propose a solution or agree on
the procedure to follow. The iroscope adaptation is
warranted for one year valid through IRISO, the
camera has its own one-year manufacturer warranty.
18 19
Iriso Camera
Bravo sur 451
Centro Histórico
Saltillo, COA 25000, Mexico
Ph: 011-52 (844) 135-4606
Cel: 011-521(844) 155-3323
irisocamera.com
irisocamera@gmail.com
made in Mexico