You are on page 1of 1

KEY PLAN

MATCHLINE A-A
ABUTMENT 1 PIER 1

750 70000mm (MEASURED ALONG OF BRIDGE) 90000mm (MEASURED ALONG OF BRIDGE)


200 550 SPAN 1 1250 1250 SPAN 2

1 3 TENDONS T1, T5, T9, T13, T17, T21, T25 & T29 5 NORTH-WE-1
TENDONS T2, T6, T10, T14, T18, T22, T26 & T30
S01-004 S01-004a S01-004a GROUT VENT STRUCTURE
TENDONS T3, T7, T11, T15, T19, T23, T27 & T31
GROUT VENT DRAIN VENT
TENDONS T4, T8, T12, T16, T20, T24, T28 & T32

*
*
*
*
X=0
*= STRESSING END
A LONGITUDINAL SECTION OF TENDONS (WEBS 1, 2, 3 & 4) @ SPAN 1
S01-002 SCALE 1 : 150m PRESTRESSING NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
X = -550 NOTED OTHERWISE.
END OF ANCHORAGE SEE MATCHLINE A-A
2. FOR GENERAL PRESTRESSING NOTES REFER TO
X=0 X = 70000 (FG-42869-PTSD-S01-001).
ABUTMENT 1 PIER 1

= MEASURED FROM REFERENCE LINE OF


DIM Y TO THE CENTER OF THE ANCHOR. A1 VERTICAL TENDONS PROFILE TABLE (WEBS 1, 2, 3 & 4) @ SPAN 1
S01-002 SCALE 1 : 150m

MATCHLINE A-A MATCHLINE B-B


FG-42869-PTSD-S01-002a
70000mm (MEASURED PIER 1 PIER 2 70000mm (MEASURED
ALONG OF BRIDGE) 90000mm (MEASURED ALONG OF BRIDGE) ALONG OF BRIDGE)
SPAN 2 1250 1250 SPAN 2 1250 1250 SPAN 3

5 9 TENDONS T1, T5, T9, T13, T17, T21, T25 & T29 5
TENDONS T2, T6, T10, T14, T18, T22, T26 & T30
S01-004a GROUT VENT S01-004c S01-004a GROUT VENT
TENDONS T3, T7, T11, T15, T19, T23, T27 & T31
DRAIN VENT
TENDONS T4, T8, T12, T16, T20, T24, T28 & T32

DRAWING REFERENCES

ST_BR_S01_04_01_001-C1, ST_BR_S01_04_02_001-C1,
ST_BR_S01_04_02_002-C1, ST_BR_S01_04_02_004-C1,
ST_BR_S01_04_02_005-C1, ST_BR_S01_04_02_006-C1,
ST_BR_S01_04_02_016-C1, ST_BR_S01_04_02_017-C1,
B LONGITUDINAL SECTION OF TENDONS (WEBS 1, 2, 3 & 4) @ SPAN 2 ST_BR_S01_04_02_019-C1, ST_BR_S01_04_02_020-C1,
S01-002 SCALE 1 : 150m ST_BR_S01_04_02_021-C1 & ST_BR_S01_04_02_022-C

SEE MATCHLINE B-B


SEE MATCHLINE A-A FG-42869-PTSD-S01-002a
X = 70000 X = 160000 1 10.04.2018 REVISED AS MARKED
PIER 1 PIER 2 0 23.11.2017 ISSUED FOR APPROVAL
NO. DATE DESCRIPTION
Client

Consultant

Contractor

PT Sub-contractor

Freyssinet Gulf (LLC)


P.O. Box 36211 - Dubai - United Arab Emirates
B1 VERTICAL TENDONS PROFILE TABLE (WEBS 1, 2, 3 & 4) @ SPAN 2 Tel. 04 2094900 Fax : 04 2094910
S01-002 SCALE 1 : 150m E-mail : fme@freyssinetme.ae

Project

DUBAI CREEK HARBOUR


WEB 1
ISLAND DISTRICT
WEB 2 NORTH WE-1 WEB 4
WEB 3
STRESSING DETAILS
Drawing Title
TENDON NO. OF JACKING FORCE RECOMMENDED STRESSING NORTH-WE-1 STRUCTURE
LOCATION STRANDS PER TENDON SEQUENCE END POST TENSIONING DETAILS
VERTICAL TENDON PROFILES - WEB TENDONS
T14 T18 T26 T6 T11 T23 T31 T3 (SHEET 1 OF 4)
T9 T21 T29 T1 T16 T20 T28 T8
WEB 19 3714 kN BOTH ENDS Date Reference Number
T10 T22 T30 T2 T15 T19 T27 T7
T13 T17 T25 T5 T12 T24 T32 T4 April 10, 2018 FG-42869
T1 T5
T2 T6 T9 T13 Drawn Checked By Approved By
T10 T14 T17 T21
T3 T7 T18 T22 T25 T29
T4 T8 T11 T15 T26 T30 DV FJ MM
T12 T16 T19 T23
T20 T24 T27 T31
T28 T32 NOTE : Scale
REFER TO DWG. No. FG-42869-PTSD-S01-004 AS SHOWN
C REFERENCE FOR WEB LOCATION & TENDON NUMBERING FOR WEB TENDONS FOR KEY PLAN WHERE TENDONS NUMBERING AND
S01-002 SCALE 1 : 60m DEFINITION OF Y AND Z ARE GIVEN. Drawing Number Rev.

FG-42869-PTSD-S01-002 1

You might also like