CONTENTS PAGE
3
XAH4 PTO
4
1. SAFETY PRECAUTIONS FOR PORTABLE COMPRESSORS
To be read attentively and acted accordingly before towing, lifting, operating, performing maintenance or repairing the compressor
1.1 INTRODUCTION
The policy of Atlas Copco is to provide the users of their equipment with The manufacturer does not accept any liability for any damage arising from
safe, reliable and efficient products. Factors taken into account are among the use of non-original parts and for modifications, additions or conversions
others: made without the manufacturer’s approval in writing.
- the intended and predictable future use of the products, and the
If any statement in this manual does not comply with local legislation, the
environments in which they are expected to operate,
stricter of the two shall be applied.
- applicable rules, codes and regulations,
- the expected useful product life, assuming proper service and Statements in these safety precautions should not be interpreted as
maintenance, suggestions, recommendations or inducements that it should be used in
- providing the manual with up-to-date information. violation of any applicable laws or regulations.
Before handling any product, take time to read the relevant instruction
manual. Besides giving detailed operating instructions, it also gives specific
information about safety, preventive maintenance, etc.
Keep the manual always at the unit location, easy accessible to the operating 1.2 GENERAL SAFETY PRECAUTIONS
personnel.
See also the safety precautions of the engine and possible other equipment, 1 The owner is responsible for maintaining the unit in a safe operating
which are separately sent along or are mentioned on the equipment or parts condition. Unit parts and accessories must be replaced if missing or
of the unit. unsuitable for safe operation.
These safety precautions are general and some statements will therefore not 2 The supervisor, or the responsible person, shall at all times make sure
always apply to a particular unit. that all instructions regarding machinery and equipment operation and
Only people that have the right skills should be allowed to operate, adjust, maintenance are strictly followed and that the machines with all
perform maintenance or repair on Atlas Copco equipment. It is the accessories and safety devices, as well as the consuming devices, are in
responsibility of management to appoint operators with the appropriate good repair, free of abnormal wear or abuse, and are not tampered with.
training and skill for each category of job. 3 Whenever there is an indication or any suspicion that an internal part of
Skill level 1: Operator a machine is overheated, the machine shall be stopped but no inspection
covers shall be opened before sufficient cooling time has elapsed; this to
An operator is trained in all aspects of operating the unit with the push- avoid the risk of spontaneous ignition of oil vapour when air is admitted.
buttons, and is trained to know the safety aspects.
4 Normal ratings (pressures, temperatures, speeds, etc.) shall be durably
Skill level 2: Mechanical technician marked.
A mechanical technician is trained to operate the unit the same as the
operator. In addition, the mechanical technician is also trained to perform 5 Operate the unit only for the intended purpose and within its rated limits
maintenance and repair, as described in the instruction manual, and is (pressure, temperature, speeds, etc.).
allowed to change settings of the control and safety system. A mechanical 6 The machinery and equipment shall be kept clean, i.e. as free as possible
technician does not work on live electrical components. from oil, dust or other deposits.
Skill level 3: Electrical technician 7 To prevent an increase in working temperature, inspect and clean heat
An electrical technician is trained and has the same qualifications as both the transfer surfaces (cooler fins, intercoolers, water jackets, etc.) regularly.
operator and the mechanical technician. In addition, the electrical technician See the maintenance schedule.
may carry out electrical repairs within the various enclosures of the unit. 8 All regulating and safety devices shall be maintained with due care to
This includes work on live electrical components. ensure that they function properly. They may not be put out of action.
Skill level 4: Specialist from the manufacturer 9 Care shall be taken to avoid damage to safety valves and other pressure-
This is a skilled specialist sent by the manufacturer or its agent to perform relief devices, especially to avoid plugging by paint, oil coke or dirt
complex repairs or modifications to the equipment. accumulation, which could interfere with the functioning of the device.
In general it is recommended that not more than two people operate the unit, 10 Pressure and temperature gauges shall be checked regularly with regard
more operators could lead to unsafe operating conditions. Take necessary to their accuracy. They shall be replaced whenever outside acceptable
steps to keep unauthorized persons away from the unit and eliminate all tolerances.
possible sources of danger at the unit.
11 Safety devices shall be tested as described in the maintenance schedule
When handling, operating, overhauling and/or performing maintenance or of the instruction manual to determine that they are in good operating
repair on Atlas Copco equipment, the mechanics are expected to use safe condition.
engineering practices and to observe all relevant local safety requirements
12 Mind the markings and information labels on the unit.
and ordinances. The following list is a reminder of special safety directives
and precautions mainly applicable to Atlas Copco equipment. 13 In the event the safety labels are damaged or destroyed, they must be
replaced to ensure operator safety.
These safety precautions apply to machinery processing or consuming air.
Processing of any other gas requires additional safety precautions typical to 14 Keep the work area neet. Lack of order will increase the risk of
the application and are not included herein. accidents.
Neglecting the safety precautions may endanger people as well as 15 When working on the unit, wear safety clothing. Depending on the kind
environment and machinery: of activities these are: safety glasses, ear protection, safety helmet
- endanger people due to electrical, mechanical or chemical influences, (including visor), safety gloves, protective clothing, safety shoes. Do not
- endanger the environment due to leakage of oil, solvents or other wear the hair long and loose (protect long hair with a hairnet), or wear
substances, loose clothing or jewelry.
- endanger the machinery due to function failures. 16 Take precautions against fire. Handle fuel, oil and anti-freeze with care
All responsibility for any damage or injury resulting from neglecting these because they are inflammable substances. Do not smoke or approach
precautions or by non-observance of ordinary caution and due care required with naked flame when handling such substances. Keep a fire-
in handling, operating, maintenance or repair, also if not expressly extinguisher in the vicinity.
mentioned in this instruction manual, is disclaimed by Atlas Copco.
5
1.3 SAFETY DURING TRANSPORT AND 1.4 SAFETY DURING USE AND OPERATION
INSTALLATION
1 When the unit has to operate in a fire-hazardous environment, each
engine exhaust has to be provided with a spark arrestor to trap
To lift a unit, all loose or pivoting parts, e.g. doors and towbar, shall first be
incendiary sparks.
securely fastened.
2 The exhaust contains carbon monoxide which is a lethal gas. When the
Do not attach cables, chains or ropes directly to the lifting eye; apply a crane
unit is used in a confined space, conduct the engine exhaust to the
hook or lifting shackle meeting local safety regulations. Never allow sharp
outside atmosphere by a pipe of sufficient diameter; do this in such a
bends in lifting cables, chains or ropes.
way that no extra back pressure is created for the engine. If necessary,
Helicopter lifting is not allowed. install an extractor. Observe any existing local regulations. Make sure
It is strictly forbidden to dwell or stay in the risk zone under a lifted load. that the unit has sufficient air intake for operation. If necessary, install
Never lift the unit over people or residential areas. Lifting acceleration and extra air intake ducts.
retardation shall be kept within safe limits.
3 When operating in a dust-laden atmosphere, place the unit so that dust is
1 Before towing the unit: not carried towards it by the wind. Operation in clean surroundings
- ascertain that the pressure vessel(s) is (are) depressurized, considerably extends the intervals for cleaning the air intake filters and
- check the towbar, the brake system and the towing eye. Also check the cores of the coolers.
the coupling of the towing vehicle,
4 Close the compressor air outlet valve before connecting or
- check the towing and brake capability of the towing vehicle,
disconnecting a hose. Ascertain that a hose is fully depressurized before
- check that the towbar, jockey wheel or stand leg is safely locked in
disconnecting it. Before blowing compressed air through a hose or air
the raised position,
line, ensure that the open end is held securely, so that it cannot whip and
- ascertain that the towing eye can swivel freely on the hook,
cause injury.
- check that the wheels are secure and that the tyres are in good
condition and inflated correctly, 5 The air line end connected to the outlet valve must be safeguarded with
- connect the signalisation cable, check all lights and connect the a safety cable, attached next to the valve.
pneumatic brake couplers, 6 No external force may be exerted on the air outlet valves, e.g. by pulling
- attach the safety break-away cable or safety chain to the towing on hoses or by installing auxiliary equipment directly to a valve, e.g. a
vehicle, water separator, a lubricator, etc. Do not step on the air outlet valves.
- remove wheel chocks, if applied, and disengage the parking brake.
7 Never move a unit when external lines or hoses are connected to the
2 To tow a unit use a towing vehicle of ample capacity. Refer to the outlet valves, to avoid damage to valves, manifold and hoses.
documentation of the towing vehicle.
8 Do not use compressed air from any type of compressor, without taking
3 If the unit is to be backed up by the towing vehicle, disengage the extra measures, for breathing purposes as this may result in injury or
overrun brake mechanism (if it is not an automatic mechanism). death. For breathing air quality, the compressed air must be adequately
4 Never exceed the maximum towing speed of the unit (mind the local purified according to local legislation and standards. Breathing air must
regulations). always be supplied at stable, suitable pressure.
5 Place the unit on level ground and apply the parking brake before 9 Distribution pipework and air hoses must be of correct diameter and
disconnecting the unit from the towing vehicle. Unclip the safety break- suitable for the working pressure. Never use frayed, damaged or
away cable or safety chain. If the unit has no parking brake or jockey deteriorated hoses. Replace hoses and flexibles before the lifetime
wheel, immobilize the unit by placing chocks in front of and/or behind expires. Use only the correct type and size of hose end fittings and
the wheels. When the towbar can be positioned vertically, the locking connections.
device must be applied and kept in good order. 10 If the compressor is to be used for sand-blasting or will be connected to
6 To lift heavy parts, a hoist of ample capacity, tested and approved a common compressed-air system, fit an appropriate non-return valve
according to local safety regulations, shall be used. (check valve) between compressor outlet and the connected sand-
blasting or compressed-air system. Observe the right mounting position/
7 Lifting hooks, eyes, shackles, etc., shall never be bent and shall only
direction.
have stress in line with their design load axis. The capacity of a lifting
device diminishes when the lifting force is applied at an angle to its load 11 Before removing the oil filler plug, ensure that the pressure is released
axis. by opening an air outlet valve.
8 For maximum safety and efficiency of the lifting apparatus all lifting 12 Never remove a filler cap of the cooling water system of a hot engine.
members shall be applied as near to perpendicular as possible. If Wait until the engine has sufficiently cooled down.
required, a lifting beam shall be applied between hoist and load. 13 Never refill fuel while the unit is running, unless otherwise stated in the
9 Never leave a load hanging on a hoist. Atlas Copco Instruction Book (AIB). Keep fuel away from hot parts
such as air outlet pipes or the engine exhaust. Do not smoke when
10 A hoist has to be installed in such a way that the object will be lifted
fuelling. When fuelling from an automatic pump, an earthing cable
perpendicular. If that is not possible, the necessary precautions must be
should be connected to the unit to discharge static electricity. Never spill
taken to prevent load-swinging, e.g. by using two hoists, each at
nor leave oil, fuel, coolant or cleansing agent in or around the unit.
approximately the same angle not exceeding 30° from the vertical.
11 Locate the unit away from walls. Take all precautions to ensure that hot
air exhausted from the engine and driven machine cooling systems
cannot be recirculated. If such hot air is taken in by the engine or driven
machine cooling fan, this may cause overheating of the unit; if taken in
for combustion, the engine power will be reduced.
6
14 All doors shall be shut during operation so as not to disturb the cooling 1.5 SAFETY DURING MAINTENANCE AND REPAIR
air flow inside the bodywork and/or render the silencing less effective.
A door should be kept open for a short period only e.g. for inspection or
adjustment. Maintenance, overhaul and repair work shall only be carried out by
adequately trained personnel; if required, under supervision of someone
15 Periodically carry out maintenance works according to the maintenance qualified for the job.
schedule.
1 Use only the correct tools for maintenance and repair work, and only
16 Stationary housing guards are provided on all rotating or reciprocating tools which are in good condition.
parts not otherwise protected and which may be hazardous to personnel.
Machinery shall never be put into operation, when such guards have 2 Parts shall only be replaced by genuine Atlas Copco replacement parts.
been removed, before the guards are securely reinstalled. 3 All maintenance work, other than routine attention, shall only be
17 Noise, even at reasonable levels, can cause irritation and disturbance undertaken when the unit is stopped. Steps shall be taken to prevent
which, over a long period of time, may cause severe injuries to the inadvertent starting. In addition, a warning sign bearing a legend such as
nervous system of human beings. ”work in progress; do not start” shall be attached to the starting
When the sound pressure level, at any point where personnel normally equipment.
has to attend, is: On engine-driven units the battery shall be disconnected and removed or
below 70 dB(A): no action needs to be taken, the terminals covered by insulating caps.
above 70 dB(A): noise-protective devices should be provided for On electrically driven units the main switch shall be locked in open
people continuously being present in the room, position and the fuses shall be taken out. A warning sign bearing a
below 85 dB(A): no action needs to be taken for occasional visitors legend such as ”work in progress; do not supply voltage” shall be
staying a limited time only, attached to the fuse box or main switch.
above 85 dB(A): room to be classified as a noise-hazardous area and 4 Before dismantling any pressurized component, the compressor or
an obvious warning shall be placed permanently at equipment shall be effectively isolated from all sources of pressure and
each entrance to alert people entering the room, for the entire system shall be relieved of pressure. Do not rely on non-return
even relatively short times, about the need to wear valves (check valves) to isolate pressure systems. In addition, a warning
ear protectors, sign bearing a legend such as ”work in progress; do not open” shall be
above 95 dB(A): the warning(s) at the entrance(s) shall be completed attached to each of the outlet valves.
with the recommendation that also occasional
visitors shall wear ear protectors, 5 Prior to stripping an engine or other machine or undertaking major
above 105 dB(A): special ear protectors that are adequate for this noise overhaul on it, prevent all movable parts from rolling over or moving.
level and the spectral composition of the noise shall 6 Make sure that no tools, loose parts or rags are left in or on the machine.
be provided and a special warning to that effect shall Never leave rags or loose clothing near the engine air intake.
be placed at each entrance.
7 Never use flammable solvents for cleaning (fire-risk).
18 Insulation or safety guards of parts the temperature of which can be in
8 Take safety precautions against toxic vapours of cleaning liquids.
excess of 80 °C (175 °F) and which may be accidentally touched by
personnel shall not be removed before the parts have cooled to room 9 Never use machine parts as a climbing aid.
temperature. 10 Observe scrupulous cleanliness during maintenance and repair. Keep
19 Never operate the unit in surroundings where there is a possibility of away dirt, cover the parts and exposed openings with a clean cloth,
taking in flammable or toxic fumes. paper or tape.
20 If the working process produces fumes, dust or vibration hazards, etc., 11 Never weld on or perform any operation involving heat near the fuel or
take the necessary steps to eliminate the risk of personnel injury. oil systems. Fuel and oil tanks must be completely purged, e.g. by
steam-cleaning, before carrying out such operations. Never weld on, or
21 When using compressed air or inert gas to clean down equipment, do so
in any way modify, pressure vessels. Disconnect the alternator cables
with caution and use the appropriate protection, at least safety glasses,
during arc welding on the unit.
for the operator as well as for any bystander. Do not apply compressed
air or inert gas to your skin or direct an air or gas stream at people. 12 Support the towbar and the axle(s) securely if working underneath the
Never use it to clean dirt from your clothes. unit or when removing a wheel. Do not rely on jacks.
22 When washing parts in or with a cleaning solvent, provide the required 13 Do not remove any of, or tamper with, the sound-damping material.
ventilation and use appropriate protection such as a breathing filter, Keep the material free of dirt and liquids such as fuel, oil and cleansing
safety glasses, rubber apron and gloves, etc. agents. If any sound-damping material is damaged, replace it to prevent
the sound pressure level from increasing.
23 Safety shoes should be compulsory in any workshop and if there is a
risk, however small, of falling objects, wearing of a safety helmet should 14 Use only lubricating oils and greases recommended or approved by
be included. Atlas Copco or the machine manufacturer. Ascertain that the selected
lubricants comply with all applicable safety regulations, especially with
24 If there is a risk of inhaling hazardous gases, fumes or dust, the
regard to explosion or fire-risk and the possibility of decomposition or
respiratory organs must be protected and depending on the nature of the
generation of hazardous gases. Never mix synthetic with mineral oil.
hazard, so must the eyes and skin.
15 Protect the engine, alternator, air intake filter, electrical and regulating
25 Remember that where there is visible dust, the finer, invisible particles
components, etc., to prevent moisture ingress, e.g. when steam-cleaning.
will almost certainly be present too; but the fact that no dust can be seen
is not a reliable indication that dangerous, invisible dust is not present in 16 When performing any operation involving heat, flames or sparks on a
the air. machine, the surrounding components shall first be screened with non-
flammable material.
26 Never operate the unit at pressures or speeds below or in excess of its
limits as indicated in the technical specifications. 17 Never use a light source with open flame for inspecting the interior of a
machine.
7
18 When repair has been completed, the machine shall be barred over at 1.7 SPECIFIC SAFETY PRECAUTIONS
least one revolution for reciprocating machines, several revolutions for
rotary ones to ensure that there is no mechanical interference within the
machine or driver. Check the direction of rotation of electric motors Batteries
when starting up the machine initially and after any alteration to the When servicing batteries, always wear protecting clothing and glasses.
electrical connection(s) or switch gear, to check that the oil pump and
the fan function properly. 1 The electrolyte in batteries is a sulphuric acid solution which is fatal if it
hits your eyes, and which can cause burns if it contacts your skin.
19 Maintenance and repair work should be recorded in an operator’s Therefore, be careful when handling batteries, e.g. when checking the
logbook for all machinery. Frequency and nature of repairs can reveal charge condition.
unsafe conditions.
2 Install a sign prohibiting fire, open flame and smoking at the post where
20 When hot parts have to be handled, e.g. shrink fitting, special heat- batteries are being charged.
resistant gloves shall be used and, if required, other body protection
shall be applied. 3 When batteries are being charged, an explosive gas mixture forms in the
cells and might escape through the vent holes in the plugs.
21 When using cartridge type breathing filter equipment, ascertain that the Thus an explosive atmosphere may form around the battery if
correct type of cartridge is used and that its useful service life is not ventilation is poor, and can remain in and around the battery for several
surpassed. hours after it has been charged. Therefore:
22 Make sure that oil, solvents and other substances likely to pollute the - never smoke near batteries being, or having recently been, charged,
environment are properly disposed of. - never break live circuits at battery terminals, because a spark usually
occurs.
23 Before clearing the unit for use after maintenance or overhaul, check
that operating pressures, temperatures and speeds are correct and that 4 When connecting an auxiliary battery (AB) in parallel to the unit battery
the control and shutdown devices function correctly. (CB) with booster cables: connect the + pole of AB to the + pole of CB,
then connect the - pole of CB to the mass of the unit. Disconnect in the
reverse order.
Safety valves
All adjustments or repairs are to be done by an authorized representative of
the valve supplier (see maintenance schedule).
8
INSTRUCTION MANUAL
2. LEADING PARTICULARS
2.1 DESCRIPTION OF SAFETY PICTOGRAMS USED – Regulation
IN THIS MANUAL The compressor is provided with a continuous regulating system
and a blow-down valve. The valve is closed during operation by
This symbol draws your attention to dangerous outlet pressure of the compressor element and opens by air receiver
situations. The operation concerned may endanger pressure when the compressor is stopped.
persons and cause injuries.
When the air consumption increases, the air receiver pressure will
This symbol is followed by supplementary information. decrease and vice versa.
This receiver pressure variation is sensed by the regulating valve
which, by means of control air to the unloader, matches the air
output to the air consumption. The air receiver pressure is
maintained between the pre-selected working pressure and the
corresponding unloading pressure.
– Cooling system
The compressor is provided with an oil cooler.
– Safety devices
A thermal shutdown switch protects the compressor against
overheating. The air receiver is provided with a safety valve.
– Bodywork
The compressor element, air and oil filters, oil cooler and regulating
components are enclosed in a simple, weather-proof canopy. The
side panels are easily detachable by four quick fasteners.
The air filter may be serviced without removing a side panel.
All drain plugs are on the outside of the canopy to facilitate oil
change.
Fig.2.1 General view of XAH4 PTO Transport beams are integrated in the frame for installation with a
fork-lift truck.
– Compressor
The compressor casing houses two screw-type rotors, mounted on
ball and roller bearings. The male rotor, driven by the engine, drives
the female rotor. The element delivers pulsation-free air.
Injected oil is used for sealing, cooling and lubricating purposes.
9
XAH4 PTO
AR
SG
SP
UA
VIS
MPV SV
AR
FP OF
AF
OLG AH
AO RV
DaP
CIP
PG
TG
CP
F
OSV
DP OC CV CE
SDL
OC
SP
10
INSTRUCTION MANUAL
Electrocution hazard.
Indicators
Reset fuse. – Temperature gauge (TG).
Indicates the air outlet temperature of the compressor element
(CE).
Prohibition to open air valves without connected hoses.
– Working pressure gauge (PG).
Indicates the air receiver pressure.
Compressor loaded. – Oil level gauge (OLG).
Indicates the oil level in the air receiver.
Airfilter. Controls
– Safety valve (SV).
Compressor temperature too high. Releases air when the air receiver pressure is 18 bar(e).
– Check valve (CV).
Prevents blow-back of compressed air when the compressor is
Rotation direction. stopped.
– Minimum pressure valve (MPV).
Prevents the air receiver pressure from dropping below 5 bar(e).
Inlet.
– Blow-down valve (BDV).
Depressurizes the air receiver (AR).
Outlet. – Oil filter by-pass valve.
Opens when the pressure drop over the oil filter (OF) is above
normal due to clogging of the element. The oil then by-passes the
Compressor oil drain. element without being filtered. For this reason, it is imperative to
replace the oil filter at regular intervals.
Read the instruction manual before starting. – Oil stop valve (OSV).
Lets the oil run from the air receiver (AR) to the compressor
element (CE). Opens when the unit is started. Closes when the
Service every 24 hours. unit is stopped to prevent the compressor element from flooding
with oil.
Warning!
– Flow restrictor (FR).
Part under pressure. Manages the oil flow from the air receiver/oil separator (AR/OS)
to the compressor element (CE), to minimize the leaking of air to
the compressor element.
11
XAH4 PTO
RV
VI S TV UA
AF
SVA
LV
BOV VH
PG
FR
OF
MPV
GC
CE AOV
SL
PM
OS
SV
OC
F OLG AR
FP
OSV DP CV DP TS
TG DP
Fig. 2.4
DP
BDV
AF Air filter F Fan OLG Oil level gauge TG Temperature gauge
AOV Air outlet valve (local FP Filler plug (compressor OS Oil separator TS Temperatur switch
installation) oil) OSV Oil stop valve TV Throttle valve
AR Air receiver FR Flow restrictor PG Pressure gauge UA Unloader assembly
BDV Blow-down valve GC Gear casing PM Prime mover VH Vent hole
BOV Bleed-off valve LV Loading solenoid valve RV Regulating valve VIS Vacuum indicator switch
CE Compressor element MPV Minimum pressure valve SL Scavenge line
CV Check valve OC Oil cooler SV Safety valve
DP Drain plug OF Oil filter SVA Selector valve
12
INSTRUCTION MANUAL
2.6 AIR FLOW (SEE FIG. 2.4) 2.8 CONTINUOUS REGULATING SYSTEM
(SEE FIG. 2.4)
Air drawn through the air filter (AF) into the compressor element
(CE) is compressed. At the element outlet, compressed air and oil The compressor is provided with a continuous regulating system.
pass into the air receiver/oil separator (AR/OS). This system is provided with a blow-down valve (BDV). The valve
The check valve (CV) prevents blow-back of compressed air when is closed during operation by outlet pressure of the compressor
the compressor is stopped. In the air receiver/oil separator (AR/OS), element and opens by air receiver pressure when the compressor is
most of the oil is removed from the air/oil mixture; the remaining oil stopped.
is removed by the separator element. When the air consumption increases, the air receiver pressure will
The oil collects in the receiver and on the bottom of the separator decrease and vice versa. This receiver pressure variation is sensed
element. by the regulating valve which, by means of control air to the
unloader, matches the air output to the air consumption. The air
The air leaves the receiver via a minimum pressure valve (MPV) receiver pressure is maintained between the pre-selected working
which prevents the receiver pressure from dropping below the pressure and the corresponding unloading pressure.
minimum working pressure (specified in section 8.3), even when the
air outlet valve is open. This ensures adequate oil injection and When starting the compressor, the throttle valve (TV) is kept open
prevents oil consumption. by spring force. The compressor element (CE) takes in air and
pressure builds up in the receiver. The throttle valve is closed.
A temperature switch (TS) is comprised in the system.
The air output is controlled from maximum output (100%) to no
A blow-down valve (BDV) automatically depressurizes the air output (0%) by air inlet throttling.
receiver (AR) when the compressor is stopped.
If the air consumption is equal to or exceeds the maximum air
output, the throttle valve is fully open.
2.7 OIL SYSTEM (SEE FIG. 2.4) If the air consumption is less than the maximum air output, the
regulating valve supplies control air to the throttle valve to reduce
The lower part of the air receiver (AR) serves as oil tank. the air output and holds air receiver pressure between the normal
working pressure and the corresponding unloading pressure of
Air pressure forces the oil from the air receiver/oil separator (AR/ approx. 2 bar above the normal working pressure.
OS) through the oil cooler (OC), oil filters (OF) and oil stop valve
(OSV) to the compressor element (CE). When the air consumption is resumed, the throttle valve gradually
opens the air intake.
The compressor element has an oil gallery in the bottom of its
casing. The oil for rotor lubrication, cooling and sealing is injected The construction of the regulating valve is such that any increase
through holes in the gallery. (decrease) of the air receiver pressure above the pre-set valve
opening pressure results in a proportional increase (decrease) of the
Lubrication of the bearings is ensured by oil injected into the control pressure to the throttle valve.
bearing housings.
Part of the control air is vented to atmosphere, and any condensate
The injected oil, mixed with the compressed air, leaves the discharged, through the vent holes (VH).
compressor element and re-enters the air receiver, where it is
separated from the air as described in section 2.6. The oil that
collects in the bottom of the oil separator element is returned to the
system through scavenging line (SL), which is provided with a flow
restrictor (FR).
The oil filter by-pass valve opens when the pressure drop over the
filter is above normal because of a clogged filter. The oil then by-
passes the filter without being filtered. For this reason, the oil filter
must be replaced at regular intervals (see section 4.1).
13
XAH4 PTO
3. OPERATING INSTRUCTIONS
3.1 TRANSPORT INSTRUCTIONS 3.3 STARTING
Strong, integrated beams (1) within the framework of the unit mean Ascertain that the air receiver pressure is fully released before
that installation can be easily performed with use of a fork-lift truck.
starting.
Close the main switch (see page 268) and start the prime mover
(Fig. 2.4, PM) according to the instructions of the manufacturer.
Leave the cover in place during transport. 2. Check the level of the compressor oil. The pointer of the oil level
gauge (Fig. 2.4, OLG) should register in the upper extremity of
the green range. If the level is too low, stop the unit and wait
Avoid knocks and violent shaking during transport. approx. 10 minutes to allow the air to escape from the oil. Add
oil if necessary. See section 4.2 for the oil to be used.
Before removing the oil filler plug (Fig. 2.4, FP) ensure
3.2 BEFORE STARTING that the pressure is released by opening the air outlet
valve(s) (Fig. 2.4, AOV).
1. Check the level of the compressor oil. The pointer of the oil level
3. Check that the regulating valve (Fig. 2.4, RV) is correctly
gauge (Fig. 2.4, OLG) should register in the upper extremity of
adjusted.
the green range. Add oil if necessary. See section 4.2 for the oil
to be used. 4. Check the air outlet temperature of the compressor element,
which is shown on the temperature gauge (Fig. 2.4, TG).
Before removing the oil filler plug (Fig. 2.4, FP), ensure
Reinstall the side panel after checking.
that the pressure is released by opening the air outlet
valve(s) (Fig. 2.4, AOV).
Normally, there is no need to add oil between two oil changes; if 3.6 STOPPING
there is, check the source of oil consumption.
1. Close the air outlet valve(s) (Fig. 2.4, AOV) and run the unit
2. Empty the dust trap of the air filter (Fig. 2.4, AF). See section
unloaded for some minutes.
5.1.3.
2. Stop the prime mover (Fig. 2.4, PM) and open the main switch.
3. Attach the air line(s) to the closed air outlet valve(s).
No external force may be applied to the air outlet
valve(s), e.g. by pulling hoses or by connecting
equipment directly to the valve(s) (e.g. a water
separator, a lubricator, pipe extensions, etc.).
14
INSTRUCTION MANUAL
Notes:
1) More frequently when operating in a dusty environment.
2) Replace the element when the pressure drop exceeds 0.8 bar.
15
XAH4 PTO
16
INSTRUCTION MANUAL
Keep the compressor oil cooler (1) clean to maintain the cooling
efficiency.
4.8 COMPRESSOR ELEMENT OVERHAUL
Steam cleaning in combination with a cleansing agent may be
applied. When a compressor element is due for overhaul, it is recommended
The fan side surface of the cooler is accessible by removing the side to have it done by Atlas Copco. This guarantees the use of genuine
panels. parts and correct tools with care and precision.
17
XAH4 PTO
18
INSTRUCTION MANUAL
19
XAH4 PTO
6. PROBLEM SOLVING
The trouble-shooting chart helps to solve mechanical problems.
An electrical fault must be traced by an electrician.
It is assumed that the prime mover is in good condition.
Make sure that the wires are not damaged and that they are clamped
tight to their terminals.
1. Compressor loaded a. Loading solenoid valve (LV) stuck in loaded a. Remove and check loading solenoid valve.
automatically to full position. Replace valve if necessary.
capacity after starting. b. Air intake throttle valve (TV) stuck in opened b. Remove air filter, air intake manifold and
position. throttle valve spring seat. Withdraw throttle
valve and inspect. Replace parts where
necessary.
Caution: the spring seat is fixed with 4 short
and 2 long setscrews: first remove short
screws, then release spring tension by
alternately unscrewing the long ones.
c. Air leaks in regulating system. c. Check hoses and their fittings. Stop leaks;
replace leaking hoses.
d. Loading solenoid valve (LV) defective. d. Check loading solenoid valve; correct or
replace if necessary.
2. Compressor does not a. Membrane of regulating valve (RV) cracked. a. If air blows from venting device, remove
deliver air immediately and dismantle regulating valve. Replace
after loading solenoid valve membrane.
has been energized. b. Air intake throttle valve (TV) stuck in closed b. See corrective action 1b.
position.
c. Loading solenoid valve (LV) defective. c. Check loading solenoid valve; correct or
replace if necessary.
3. Excessive compressor oil a. Oil level too high. a. Release pressure, wait approx. 10 minutes
consumption. Oil mist and drain oil to the correct level.
being discharged from air b. Flow restrictor (FR) in scavenge line (SL) b. Remove hoses and clean flow restrictor.
outlet valve(s). clogged.
c. Oil separator element defective. c. Have element removed and inspected by an
Atlas Copco Service representative.
20
INSTRUCTION MANUAL
5. Pressure in air receiver a. Regulating valve (RV) opens too late or its ball a. Adjust regulating valve. Dismantle and
(AR) rises above maximum valve spring is broken. inspect parts if valve does not respond.
and causes safety valve Replace where necessary.
(SV) to blow. b. Air leaks in regulating system. b. Check hoses and their fittings. Stop leaks;
replace leaking hoses.
c. Air intake throttle valve (TV) does not close for c. See corrective action 4g.
some reason.
d. Minimum pressure valve (MPV) d. Remove and inspect minimum pressure
malfunctioning. valve. Replace if necessary.
e. Bleed-off valve (BOV) malfunctioning. e. Remove and inspect bleed-off valve.
Replace if necessary.
6. Air and oil mist expelled a. If mainly air: check valve (CV) excessively a. Remove valve and inspect. Replace valve if
from air filter (AF) after leaking or defective. necessary. Replace air filter element and
stopping. safety cartridge. Check the oil level and add
oil if necessary. Run the unit for a few
minutes, stop and recheck the oil level.
b. If mainly oil: plunger of oil stop valve (OSV) b. See corrective action 6a.
jammed or oil stop valve defective.
21
XAH4 PTO
7. AVAILABLE OPTIONS
MAINTENANCE AIR FILTER ALARM LAMP
An alarm lamp (horn) may be connected to the vacuum indicator
switch (terminal L of socket X7, see page 269). The lamp (horn)
will light up (sound) when the filter needs to be serviced.
Nevertheless, the filter has to be serviced or replaced at the
prescribed intervals (see section 4.1).
22
INSTRUCTION MANUAL
8. TECHNICAL SPECIFICATIONS
8.1 READINGS ON GAUGES
Gauge Reading Unit Design data
Working pressure (PG2) between unloading Compressor
and working 1. Number of compression stages 2
pressure bar 2. Gear ratios 1.604
Interstage pressure (PG1) below 6.5 bar 1.723
LP compressor element 1.909
air outlet temperature (TG1) below 120 °C 2.297
2.405
HP compressor element
Other ratios on request
air outlet temperature (TG2) below 120 °C
3. Net mass without oil (approx.) kg 1180
8.2 SETTINGS OF SWITCHES AND SAFETY VALVE Oil tank separator module (OSM)
1. Oil capacity l 41
Switch Makes at Breaks at 2. Net capacity of air receiver l 180
3. Net mass without oil (approx.) kg 195
Shutdown switch
LP compressor element air outlet temperature (TS1), 4. Net mass with oil (approx.) kg 230
adjustable up to 1) – 120 °C
HP compressor element air outlet temperature (TS2), PTO package
adjustable up to 1) – 120 °C 1. Total oil capacity of unit ready to operate (approx.) l 75
Alarm switch 2. Total mass of unit ready to operate (approx.) kg 1439
Air filter vacuum indicator switch (VIS) – 50 mbar
Start preventing pressure switch
– contact 11 - 14 1.5 1 bar(e)
– contact 11 - 12 1 1.5 bar(e) Unit dimensions
Safety valve (SV) Overall length mm 1322
Opening pressure 30 bar(e) Overall width mm 1203
Overall height mm 1190
Performance data 2) 3)
1. Free air delivery at reference conditions 4) l/s 220 - 460
2. Shaft input at reference conditions 4) kW 120 - 290
3. Compressed air temperature at outlet valves (approx.) °C 75
23
XAH4 PTO
Power/Leistung/Puissance kw ★★★
1 mm = 0.039 in Transmission/Verh ältnis/Transmission i; ★★★
1 mbar = 0.401 in wc
MADE BY ATLAS COPCO AIRPOWER n.v. WILRIJK, BELGIUM
1N = 0.225 lbf
1 Nm = 0.738 lbf.ft 1615 6945 00
t °F = 32 + (1.8 x t °C)
t °C = (t °F - 32)/1.8
– A temperature difference of 1 °C = a temperature difference of 1.8 °F 1. Company code
2. Product code
3. Unit serial number
4. Name of manufacturer
5. EEC or national type approval number
6. Identification number
7. Maximum weight
8. Name buyer
9. Working pressure
10. Speed
11. Power
12. Gears
13. Manufacturing year
24