Colour codes for Thermcouple Extension and Compensating Cables
Colour code for Thermocouple Extension
Codes/Conductor and Compensating Cables combinations Characteristics of various International standards of Extension British Standard American Standard Indian Standard Electro Technical and Compensating Cables BS 1843 ANSI MC 96.1 IS 8784 Commission
Conductor Combinations Code IEC 584-3
+ VE Leg - VE Leg
Nickel Nickel +/- +/- +/- +/-
KX Chromium Aluminium 2.5°C 2.2°C 2.2°C 2.5°C
Copper- +/- +/-
VX Copper - - - - Nickel 2.5°C 2.5°C
Copper- +/- +/- +/- +/-
TX Copper Nickel 1.0°C 1.0°C 1.0°C 1.0°C
Copper- +/- +/- +/- +/-
JX IRON Nickel 2.5°C 2.2°C 2.2°C 2.5°C
Nickel Copper- +/- +/- +/- +/-
EX Chromium Nickel 2.5°C 1.7°C 1.7°C 2.5°C
Copper- +/- +/- +/-
RX Copper - - Alloy 2.5°C 1.5°C 1.5°C
Copper- +/- +/- +/- +/-
SX Copper Alloy 2.5°C 1.5°C 1.5°C 2.5°C
Copper- +/- +/-
BX Copper - - - - Alloy 0.5°C 0.5°C
5. Loop resistance for Thermocouple Conductors
LOOP RESISTANCE (MAX) FOR THERMOCOUPLE CONDUCTORS at 20ºC OHM / Km.
THERMOCOUPLE TYPE KX VX TX JX EX RX/SX
1) 20 AWG Conductor 1910 980 980 1214 2312 280
2) 18 AWG Conductor 1212 624 624 772 1470 175
3) 16 AWG Conductor 746 385 385 475 905 110
6. Loop resistance for Copper Conductors
LOOP RESISTANCE (MAX) FOR COPPER CONDUCTORS at 20°C OHM / Km.
SIZE IN SQ.MM. 0.5 0.75 18 AWG 1.0 1.5 2.5
Max. resistance Flexible Copper
79.20 50.40 45.00 36.20 25.40 15.30 at 20°C Plain Conductors
Max. resistance Solid Copper
72.00 48.00 44.00 35.40 24.20 14.50 at 20°C Plain Conductors