F1-MS200X Hand-held Mini Fiber Microscope ‘The Mini Fiber Microscopes are used for inspecting fiber terminations in the field. With their good optical performance and Integrated laser safety fiters, they provide the most critical view of fiber end faces. This ‘renders scratches highly visible and isthe clear choice for field termination in sensitive installations DAdapter interface @ Focus Control Battery cover@Eyepiece GLED switch Power Source: 3 x1.Sv button batteries Light Soure Weight: —0.34Kg Size: 190mm/7.48"L X 45mm/1.77"D White LED, rated for 100,000 hours Momentary onioff switch for light source, Fine Focus control wheel 1. Automatic onloff switch for light source 2. Two minutes delayed on/off switch Safety Filter: Built in IR fitter ‘Adapter Interface: user interchangeable adapters. Color: Black. Setup ‘The Mini Fiber Microscope comes fly assembled and requires ony few steps before itis ready fo use . 1, Begin by removing the instrument from is case. 2. You'l need to insert 3X1.5V button batteries Unscrew and remove the "Battery Cap" Insert the batteries ‘with the™side up towards the Battery Pug" side down towards the Light Switch (see Figur 2) Replace the Battery Cap and tighten 3. fyou have purchased the Fiber Microscope with @ Universal Adapter. should already bein place and your instrument is ready to use.f you purchased an adapier separately simply screw i into the threaded hole at the opposte end from the ight Switch Your instrument is ready to use. Operation In this manual we wil explain general use of the Fiber Microscope Howevertis important 10 read the specie termination instructions published by the manufacturer ofthe connector you are using Ths wl ensure proper termination Also,be sure you have read the User Safety Warning and fully understand that direct aye contact with laser light and magnified laser light should be avoided. 41 Begin by leading the potshed connector into the adapter you have purchased our Universal Adapter simply sl the connector ferule2.Smmyint the hole unl you feel tht a stop (see figured) may require a litle pressure to gett tated as our Universal adapter is equipped wth a noi gripping ‘mechanism tis important o sli the connector ful al the way tothe stp. This wl minimize any refocusing that needs tobe done when changing from one connector fo the net if you have purchased one of the dedeated adapters inser the connector ut as you would into a patch bay of mated connector. 2. Now tur the ght on The ight operates by pressing and holding the ght Switch in You can tell ifthe light is on by checking the "Backlight Window"(see figure’). If you see light through this window .you are ready to work ‘3. Once the connector is loaded and the light is on,hold the eyepiece up to your eye and begin focusing Unlike many instruments of this ype the Fiber Microscope is always centered so there fs no alignment o be done Grip the focusing adjustment(brass whee! with rubber gp see figure) and tum ito focus the image.The fst time you use the microscope to focus the image. The first time you use the microscope ,it may take a litle longer to find the image .Once you find the image ,very litle refocusing is necessary ifthe connector is property loaded. 4. Once you can visualize the connector ferrule you can evaluate It for polish quality cleave quality and Cleantiness optionally,you can hold the opposite end of a cable tothe Backlight window to give further contrast to the core .Check with the manufacturer of your connector for further instructions.

You might also like