Professional Documents
Culture Documents
FEATURES
OUTLINE DIMENSIONS
Dual-in-line package :
OUTLINE DIMENSIONS
TAPING DIMENSIONS
Forward Current IF 50 mA
( Ta = 25°C )
PARAMETER SYMBOL MIN. TYP. MAX. UNIT CONDITIONS
*3
Led Trigger Current, Current
Main Terminal
Required to Latch Output, IFT — — 5 mA
Voltage = 3V
Either Direction
COUPLED
Holding Current, Either
IH — 400 — µA
Direction
VP=9V, IF=20mA
Turn-On Time TON — 8 20 µs
RL = 100Ω
Maximum Operating
VIORM - 850 VPEAK
Isolation Voltage
Partial Discharge Diagram 1 tp=60s, qc<5pC 1275 VPEAK
Test Voltage Refer to the
Vpr
(Between Input and Diagram 1, 2
Output) Diagram 2 tp=1s, qc<5pC 1594 VPEAK
o
1) Case Temperature Tsi IF = 0, Pc = 0 130 C
Refer to the
Figure 1, 3
2) Input Current Isi Pc=0 55 mA
Ta=Tsi MIN.109
Isolation Resistance
(Test Voltage Between RISO Ta=Topr(MAX.) MIN.1011 Ω
Input and Output : DC500V)
Ta=25 oC MIN.1012
* Partial discharge test methods shall be the ones according to the specifications of
VDE 0884:1992-06
* Please don't carry out isolation test (Viso) over VINITIAL ,This product deteriorates
isolation characteristics by partial discharge due to applying high voltage
(ex. VINITIAL ). And there is possibility that this product occurs partial discharge in
operating isolation voltage (VIORM)
V VINTIAL
Vpr
t1, t2 = 1 to 10s
VIORM t3, t4 = 1s
tp (Partial Discharge Measuring Time)= 60s
tb = 62s
tini = 10s
t
t3 tp t4
t1 tini t2 tb
V
Vpr
t3, t4 = 0.1s
tp (Partial Discharge Measuring Time)= 1s
VIORM tb = 1.2s
t
t3 tp t4
tb
The partial discharge level shall not exceed 5 pC during the partial discharge measuring time
interval tp under the test conditions shown above.
CHARACTERISTICS CURVES
Fig.1 Forward Current vs. Fig.2 On-state Current vs. Ambient
Ambient Temperature Temperature
60
50
Forward current I F (mA)
30
0.05
20
10
0 0
-40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120
o o
Ambient temperature Ta ( C) Ambient temperature Ta ( C)
RL= 100
8
Forward current I F (mA)
o o
80 C 60 C
o o
6 100 C 40 oC
20 C
10
4
0 1
20 40 60 80 100 0.4 0.8 1.2 1.6 2.0
o
Ambient temperature ( C) Forward voltage VF (V)
2.6
Forward current I H (mA)
On-state voltage VTM(V)
2.2
0.1
1.8
1.4
1.0 0.01
20 40 60 80 100 20 40 60 80 100
o o
Ambient temperature Ta ( C) Ambient Temperature Ta ( C)
CHARACTERISTICS CURVES
Fig.7 Turn-on Time vs. Forward Fig.8 Repetitive Peak Off-state Current
Current vs. Temperature
10 1000
VP= 9V
100
6
4
10
Idrm (nA)
2
0 1
10 20 30 40 50 20 40 60 80 100
O
Forward current I F (mA) Ambient temperature Ta ( C)
80 R= 10k
CTEST
PULSE
60 MERCURY X100
INPUT
WETTED SCOPE
RELAY D.U.T. PROBE
40
20
APPLIED VOLTAGE Vmax = 400V
0 WAVEFORM 252 V
0 0.5 1.0 1.5 2.0 2.5 3.0 0.63 Vmax 378
0 VOLTS dv/dt= =
On-state voltage VTM (V) τRC τRC τRC
Unit : mm