You are on page 1of 16

ESTIMATION OF FOOTING

TAPPERED S

NUMBER TOP
TYPES OF OF LENGTH BREADTH D (in) S (in) D/2 (in) AREA
SL. NO. FOOTING FOOTING L (ft) B (ft) (sft)
1 F-1 3 9 9 20 3 10 10.03
2 F-2 10 11 11 22 3 11 12.84
3 F-3 2 11.5 11.5 24 3 12 15.34
4 F-4 4 12.5 12.5 26 3 13 19.51
5 C.F-5 1 19 9 26 3 13 61.05
6 C.F-6 1 18 23 28 3 14 332.34
7 C.F-7 2 14 8 26 3 13 42.78
CONCRETE VOLUME
WITHOUT TAPPERED
TAPPERED SECTION SECTION
TOTAL
BOTTOM AVERAGE OF VOLUME (cft) VOLUME (cft) VOLUME
AREA (sft) AREA (sft) (cft)
81.00 45.51 11.38 135.00 439.14
121.00 66.92 16.73 221.83 2385.63
132.25 73.80 18.45 264.50 565.90
156.25 87.88 21.97 338.54 1442.05
171.00 116.02 29.01 370.50 399.51
414.00 373.17 93.29 966.00 1059.29
112.00 77.39 19.35 242.67 524.03
TOTAL= 6815.54

WET DRY
VOLUME VOLUME

6815.54 10495.93
SAND COARSE AGGREGATE

LOCAL SYLHET 3/4" DOWNGRADED 1/2" DOWNGRADED


CEMENT CEMENT
RATIO SAND SAND CRUSHING STONE CRUSHING STONE
(cft) (bags) (cft) (cft) (cft) (cft)

1908.351 1526.681 1431.26 1431.26 2862.53 2862.53


NUMBER
TYPES OF OF LENGTH BREADTH LENGTH NUMBER
SL. NO. FOOTING FOOTING L (ft) B (ft) OF ASL OF ASL BAR SIZE
1 F-1 3 9 9 8.5 22 20 mm
2 F-2 10 11 11 10.5 26 20 mm
3 F-3 2 11.5 11.5 11 28 20 mm
4 F-4 4 12.5 12.5 12 30 20 mm
TOP BAR 19 38 16 mm
5 C.F-5 1 19 9
BOTTOM BAR 19 46 20 mm
TOP BAR 18 36 16 mm
6 C.F-6 1 18 23
BOTTOM BAR 18 43 20 mm
TOP BAR 14 28 16 mm
7 C.F-7 2 14 8
BOTTOM BAR 14 34 20 mm
NUMBER
TYPES OF OF LENGTH BREADTH LENGTH NUMBER
SL. NO. FOOTING FOOTING L (ft) B (ft) OF ASB OF ASB BAR SIZE
1 F-1 3 9 9 8.5 22 20 mm
2 F-2 10 11 11 10.5 26 20 mm
3 F-3 2 11.5 11.5 11 28 20 mm
4 F-4 4 12.5 12.5 12 30 20 mm
TOP BAR 9 18 16 mm
5 C.F-5 1 19 9
BOTTOM BAR 9 22 20 mm

TOP BAR

6 C.F-6 1 18 23
23 46 16 mm

BOTTOM BAR
23 55 20 mm
TOP BAR 8 16 16 mm
7 C.F-7 2 14 8
BOTTOM BAR 8 19 20 mm
BAR TOTAL LENGTH OF TOTAL WEIGHT OF BAR TOTAL LENGTH OF
WEIGHT ASL IN EACH ASL IN EACH LENGTH NUMBER WEIGHT ASB IN EACH
(Kg/ft) FOOTING (ft) FOOTING (Kg) OF ASB OF ASB BAR SIZE (Kg/ft) FOOTING (ft)
0.75188 187 421.80 8.5 22 20 mm 0.75188 187
0.75188 273 2052.63 10.5 26 20 mm 0.75188 273
0.75188 308 463.16 11 28 20 mm 0.75188 308
0.75188 360 1082.71 12 30 20 mm 0.75188 360
0.481203 722 347.43 9 18 16 mm 0.481203 162
0.75188 874 657.14 9 22 20 mm 0.75188 198
0.481203 648 311.82 23 46 16 mm 0.481203 1058
0.75188 774 581.95 23 55 20 mm 0.75188 1265
0.481203 392 377.26 8 16 16 mm 0.481203 128
0.75188 476 715.79 8 19 20 mm 0.75188 152
TOTAL = 7011.70 TOTAL =
13070.83

BAR TOTAL LENGTH OF TOTAL WEIGHT OF


WEIGHT ASB IN EACH ASL IN EACH
(Kg/ft) FOOTING (ft) FOOTING (Kg)
0.75 187 421.80
0.75 273 2052.63
0.75 308 463.16
0.75 360 1082.71
0.48 162 77.95
0.75 198 148.87

0.48 1058 509.11

0.75 1265 951.13


0.48 128 123.19
0.75 152 228.57
TOTAL = 6059.13
TOTAL WEIGHT NUMBER
OF ASL IN EACH TYPES OF OF LENGTH BREADTH
FOOTING (Kg) SL. NO. FOOTING FOOTING L (ft) B (ft)
421.80 1 F-1 3 9 9
2052.63 2 F-2 10 11 11
463.16 3 F-3 2 11.5 11.5
1082.71 4 F-4 4 12.5 12.5
77.95 TOP BAR
5 C.F-5 1 19 9
148.87 BOTTOM BAR
509.11 TOP BAR
6 C.F-6 1 18 23
951.13 BOTTOM BAR
123.19 TOP BAR
7 C.F-7 2 14 8
228.57 BOTTOM BAR
6059.13
NUMBER
TYPES OF OF LENGTH BREADTH D (in) S (in)
SL. NO. FOOTING FOOTING L (ft) B (ft)
1 F-1 3 9 9 20 3
2 F-2 10 11 11 22 3
3 F-3 2 11.5 11.5 24 3
4 F-4 4 12.5 12.5 26 3
5 C.F-5 1 19 9 26 3
6 C.F-6 1 18 23 28 3
7 C.F-7 2 14 8 26 3
TOTAL TOTAL
LENGTH WEIGHT
OF ASL IN OF ASL IN
BAR EACH EACH
LENGTH NUMBER WEIGHT FOOTING FOOTING LENGTH NUMBER
OF ASL OF ASL BAR SIZE (Kg/ft) (ft) (Kg) OF ASB OF ASB BAR SIZE
8.5 22 20 mm 0.75188 187 421.80 8.5 22 20 mm
10.5 26 20 mm 0.75188 273 2052.63 10.5 26 20 mm
11 28 20 mm 0.75188 308 463.16 11 28 20 mm
12 30 20 mm 0.75188 360 1082.71 12 30 20 mm
19 37 16 mm 0.481203 703 338.29 9 18 16 mm
19 45 20 mm 0.75188 855 642.86 9 21 20 mm
18 35 16 mm 0.481203 630 303.16 23 45 16 mm
18 43 20 mm 0.75188 774 581.95 23 54 20 mm
14 28 16 mm 0.481203 392 377.26 8 16 16 mm
14 33 20 mm 0.75188 462 694.74 8 18 20 mm
TOTAL = 6958.56
CONCRETE VOLUME

WITHOUT
TAPPERE
D
SECTION

VOLUME
D+S (cft)

1.917 465.75
2.083 2520.83
2.250 595.13
2.417 1510.42
2.417 413.25
2.583 1069.50
2.417 541.33
TOTAL= 7116.21

3/4"
DOWNGR 1/2"
LOCAL SYLHET
WET DRY CEMENT CEMENT ADED DOWNGRADE
VOLUME VOLUME RATIO (cft) (bags) SAND SAND CRUSHIN D CRUSHING
(cft) (cft) G STONE STONE (cft)
(cft)

7116.21 10958.96 1992.538 1594.031 1494.4 1494.4 2988.8 2988.8


1908.351 1526.681 1431.26 1431.26 2862.53 2862.53

2988.808 5977.615
426.94
1494.404 2988.808

3/4"
DOWNGR 1/2"
LOCAL SYLHET
CEMENT ADED DOWNGRADE
SAND SAND CRUSHIN D CRUSHING
(bags) (cft) (cft) G STONE STONE (cft)
(cft)

1594.031 1494.4 1494.4 2988.8 2988.8


1526.681 1431.26 1431.26 2862.53 2862.53
1526.68

Practical
Chart Title Theoretical
Practical Theoretical
5977.6

5725.06

7000.00
Reinforcem
6000.00
1600
5000.00
1400
1594.0306666667

2862.52
2988.8

4000.00
1200
1526.681

3000.00
Reinforcement, kg

1000
2000.00
800
1000.00
600
0.00
C EMENT (b ags) SA N D ( c ft ) STO N E ( c ft ) 400

200

0
Pra ctical
NUMBER OF FOOTING
TYPES OF FOOTING

BREADTH B (ft)
LENGTH L (ft)

TOTAL
LENGTH TOTAL
OF ASB IN WEIGHT OF
EACH ASL IN EACH
SL. NO.

BAR WEIGHT FOOTING FOOTING LENGTH OF


(Kg/ft) (ft) (Kg) ASL
0.7518796992 187 421.80 1 F-1 3 9 9 8.5
0.7518796992 273 2052.63 2 F-2 10 11 11 10.5
0.7518796992 308 463.16 3 F-3 2 11.5 11.5 11
0.7518796992 360 1082.71 4 F-4 4 12.5 12.5 12
0.4812030075 162 77.95 TOP BAR 19
5 C.F-5 1 19 9
0.7518796992 189 142.11 BOTTOM BAR 19
0.4812030075 1035 498.05 TOP BAR 18
6 C.F-6 1 18 23
0.7518796992 1242 933.83 BOTTOM BAR 18
0.4812030075 128 123.19 TOP BAR 14
7 C.F-7 2 14 8
0.7518796992 144 216.54 BOTTOM BAR 14
TOTAL = 6011.97
DO
WN
3/4" GR
DOWNGR AD
SYLHET
SAND ADED ED
CRUSHIN CR
(cft) G STONE US
(cft) HIN
G
1494.4 STO
1494.4 2988.8 ### 5978
1431.26 1431.26 2862.52 2862.53 ### 5725

SAND
CEMENT (bags) (cft)
STONE (cft)
1594.03 2988.8 5977.6
1526.68 2862.52 5725.06

Reinforcement
Practical Theoretical
1600 Reinforcement 1370.83 1370.83
1400

1200
Reinforcement, kg

1000

800

600

400

200

0
Pra ctical Theoretical
EACH FOOTING (Kg) (used
TOTAL WEIGHT OF ASL IN

TOTAL WEIGHT OF ASL IN


NUMBER OF ASL (used in

NUMBER OF ASL (actual)

NUMBER OF FOOTING
EACH FOOTING (Kg)

TYPES OF FOOTING
DIFFERENCE (kg)

BREADTH B (ft)
LENGTH L (ft)
DIFFERENCE

in drawing)
drawing)

(actual)

NUMBER OF
HOI

ASL
22 22 22 0 421.80 421.8045113 0.00 1 F-1 3 9 9
26 26 26 0 2052.63 2052.631579 0.00 2 F-2 10 11 11
28 28 28 0 463.16 463.1578947 0.00 3 F-3 2 11.5 11.5
30 30 30 0 1082.71 1082.706767 0.00 4 F-4 4 12.5 12.5
37 38 37 -1 347.43 338.2857143 -9.14
5 C.F-5 1 19 9
45 46 45 -1 657.14 642.8571429 -14.29
35 36 35 -1 311.82 303.1578947 -8.66
6 C.F-6 1 18 23
43 43 43 0 581.95 581.9548872 0.00
28 28 28 0 377.26 377.2631579 0.00
7 C.F-7 2 14 8
33 34 33 -1 715.79 694.7368421 -21.05
7011.70 6958.556391 -53.14
EACH FOOTING (Kg) (used
TOTAL WEIGHT OF ASL IN

TOTAL WEIGHT OF ASL IN


NUMBER OF ASL (used in

NUMBER OF ASL (actual)

EACH FOOTING (Kg)

DIFFERENCE (kg)
DIFFERENCE

in drawing)
drawing)

(actual)

LENGTH NUMBER
OF ASB OF ASB
8.5 22 22 22 0 421.80 421.80 0.00
10.5 26 26 26 0 2052.63 2052.63 0.00
11 28 28 28 0 463.16 463.16 0.00
12 30 30 30 0 1082.71 1082.71 0.00
TOP BAR 9 18 18 18 0 77.95 77.95 0.00
BOTTOM BAR 9 21 22 21 -1 148.87 142.11 -6.77
TOP BAR 23 45 46 45 -1 509.11 498.05 -11.07
BOTTOM BAR 23 54 55 54 -1 951.13 933.83 -17.29
TOP BAR 8 16 16 16 0 123.19 123.19 0.00
BOTTOM BAR 8 18 19 18 -1 228.57 216.54 -12.03
6059.13 6011.969925 -47.16