Design of combined footing CF1:

fcu = 35 N/smm fy = 460 N/smm

Left column load = 507 kN Safe bearing capacity = 120 kN/m2


Right column load = 397 kN Overburden height = 0.90 m
Self weight = 47 kN
Overburden = 167 kN Spacing of columns = 1.70 m
Total load = 1118 kN C.G. of load from left = 0.75 m

Left column breadth = 400 mm Area of footing reqd. = 6.42 m2


width = 400 mm Length of footing = 3.60 m
Right column breadth = 400 mm Width of footing = 2.30 m
width = 400 mm Footing thickness = 450 mm A prvd.
Net upward pressure = 109 kN/m2 Area of footing provided = 8.28 m2 1

Short span Long span


Max. cantilever proj. = 0.95 m Max. cantilever proj. = 0.85 m As min
Max. B.M. /m width = 49 kNm Max. cant. moment /m = 40 kNm 510
Max span moment/m = 0 kNm

K = M/bd2fcu = 0.010 N/mm2 K = M/bd2fcu = 0.007 N/mm2


Z = 357 mm Z = 372 mm No of bars
18
As required /m width = 345 mm2 As required /m width = 267 mm2 11
Diameter of bars = 16 mm Diameter of bars = 16 mm As prvd.
Spacing of bars = 200 mm Spacing of bars = 200 mm 292%
As provided/m width = 1005 mm2 As provided/m width = 1005 mm2 377%

Punch shear = 244 kN Dist. to critical section = 475 mm


Punch shear stress = 0.10 N/mm2
Shear force = 52 kN 1
Allow.shear stress = 0.40 N/mm2 Shear stress = 0.14 N/mm2

of combined footing CF1: 230 x 360 x 45 16 @ 200 16 @ 200