You are on page 1of 2

®

dseGenset

dse8610 MKII
ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


BS EN 61000-6-2
SYNCHRONISING AUTO START LOAD SHARE EMC Generic Immunity Standard for the
Industrial Environment
CONTROL MODULE BS EN 61000-6-4
EMC Generic Emission Standard for the
Industrial Environment

ELECTRICAL SAFETY
The DSE8610 MKII is an easy to Designed to offer increased built in KEY LOAD SHARE FEATURES: BS EN 60950
use Synchronising Auto Start support for active sensors for 0 V • Peak lopping/sharing (with Safety of Information Technology Equipment,
Control Module suitable for use in a to 10 V & 4 mA to 20 mA. appropriate DSE mains including Electrical Business Equipment
multi-generator loadshare system, Comprehensive communication controller) TEMPERATURE
designed to synchronise up to 32 and system expansion options are • Sequential set start BS EN 60068-2-1
generators including electronic and available. • Manual voltage/frequency Ab/Ae Cold Test -30 oC
BS EN 60068-2-2
non-electronic engines. adjustment Bb/Be Dry Heat +70 oC
Using the DSE PC Configuration • R.O.C.O.F. and vector shift
VIBRATION
The DSE8610 MKII monitors the Suite Software allows easy protection BS EN 60068-2-6
generator and indicates operational alteration of the operational • Generator load demand Ten sweeps in each of three major axes
status and fault conditions, sequences, timers and alarms. With • Automatic hours run balancing 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz at 2 gn
automatically starting or stopping all communication ports capable of • Mains (Utility) decoupling HUMIDITY
the engine on load demand or fault being active at the same time, the • Mains (Utility) decoupling BS EN 60068-2-30
condition. DSE8610 MKII is ideal for a wide test mode Db Damp Heat Cyclic 20/55 oC at 95% RH
48 Hours
variety of demanding load share • Dead bus sensing BS EN 60068-2-78
System alarms are annunciated on applications. • Bus failure detection Cab Damp Heat Static 40 oC at 93% RH
the LCD screen (multiple language • Direct governor and AVR control 48 Hours
options available), illuminated LED • Volts and frequency matching SHOCK
and audible sounder. • kW and kvar load sharing BS EN 60068-2-27
• Dead bus synchronising Three shocks in each of three major axes
15 gn in 11 mS
The event log will record 250 events
to facilitate easy maintenance, and DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
an extensive number of fixed and BS EN 60529
flexible monitoring, metering and IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.
protection features are included.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY


OF LOAD SHARE APPLICATIONS
DSE2130 MODEM MODBUS PC
DSE2131
DSE2133
DSE2152 2 12 8 4
DSE2157
DSE2548 232 485

DSENET ®
RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 5-35V
+
ETHERNET

MSC
DEUTZ DETROIT
ISUZU IVECO
DSE8610 MKII MSC PERKINS JOHN DEERE
CATERPILLAR LOMBARDINI
MTU SISU
8xxxMKII
7 VOLVO JCB DIESELMAX
55xx 75xx 8xxx CUMMINS YANMAR
OTHER SCANIA AND OTHERS

BUS VOLT FREE GENERATOR SENSING FUEL & START CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
CURRENT VOLTS
D+
+ W/L

1ph 2 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E/N N

ISSUE 3
®

dseGenset

dse8610
SPECIFICATION

MKII DC SUPPLY
CONTINUOUS VOLTAGE RATING

SYNCHRONISING AUTO START LOAD SHARE 5 V to 35 V Continuous

CONTROL MODULE CRANKING DROPOUTS


Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
batteries.LEDs and backlight will not be
maintained during cranking.

MAXIMUM OPERATING CURRENT


530 mA at 12 V, 280 mA at 24 V

MAXIMUM STANDBY CURRENT


320 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

GENERATOR & BUS


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
KEY FEATURES • 2 configurable volt-free relay KEY BENEFITS
• Comprehensive synchronising & outputs • Compatible in load share systems FREQUENCY RANGE
loadsharing capabilities • 4 configurable analogue/digital containing DSE5500, DSE7500, 3.5 Hz to 75 Hz

• Built in governor and AVR control inputs DSE8000 and DSE8600 MKII MAGNETIC PICKUP
• Base load (kW export) control • Built in sensors to support 0 V to series. Contact DSE for further VOLTAGE RANGE
• Positive & negative kVAr export 10 V & 4 mA to 20 mA details +/- 0.5 V to 70 V

control • 12 configurable digital inputs • 132 x 64 pixel ratio display for FREQUENCY RANGE
• Mains (Utility) decoupling • Configurable 5 stage dummy load clarity 10,000 Hz (max)
protection and load shedding outputs • Real-time clock provides accurate
INPUTS
• 4-Line back-lit LCD text display • CAN, MPU and alternator event logging DIGITAL INPUTS A TO L
• Multiple Display Languages frequency speed sensing in one • Ethernet communication, provides Negative switching
• Five key menu navigation variant builit in advanced remote ANALOGUE INPUTS A TO D
• LCD alarm indication • Real time clock monitoring. Configurable as:
• Heated display option available • Manual and automatic fuel pump • Can be integrated into building Negative switching digital input
0 V to 10 V sensor
• Customisable power-up text and control management systems (BMS) and
0 Ω to 480 Ω sensor
4 mA to 20 mA sensor
images • Engine run-time scheduler programmable logic control (PLC)
• DSENet expansion compatibility • Fuel usage monitor and low fuel • Increased input and output ® OUTPUTS
• Data logging & trending facility level alarms expansion capability via DSENet OUTPUT A & B (FUEL & START)
• Internal PLC editor • Simultaneous use of all • Licence-free PC software 15 A DC at supply voltage
• Protections disable feature communication ports • IP65 rating (with supplied gasket)
OUTPUTS C & D
• Fully configurable via PC using • Remote SCADA monitoring via offers increased resistance to water 8 A AC at 250 V AC (Volt-free)
USB, RS232, RS485 & Ethernet various DSE software applications ingress
communication • MODBUS RTU & TCP support • Advanced Internal PLC editor allows AUXILIARY OUTPUTS E TO L
2 A DC at supply voltage
• Front panel configuration with PIN with configurable MODBUS user configurable functions to meet
protection pages for integration into building specific application requirements. BUILT IN AVR GOVERNOR CONTROL

500 Ω
• Power save mode management systems (BMS) MINIMUM LOAD IMPEDANCE
• 3 phase generator sensing and • Advanced SMS messaging EXPANSION DEVICES Fully isolated
protection (additional external modem • DSE124 CAN/MSC Extender
• Generator current and power required) • DSE2130 Input Expansion Module GAIN VOLTAGE
0 V to 10 V DC
monitoring (kW, kvar, kVA, pf) • Start & stop capability via SMS • DSE2131 Ratio-metric Input Fully isolated
• kW and kvar overload alarms messaging Expansion Module
• Reverse power alarms • 3 configurable maintenance • DSE2133 RTD & Thermo-couple OFFSET VOLTAGE
0 V to 10 V DC
• Over current protection alarms Expansion Module Fully isolated
• Unbalanced load protection • Compatible with a wide range of • DSE2152 Ratio-metric Output
• Independent earth fault protection CAN engines, including tier 4 Expansion Module DIMENSIONS
OVERALL
• Breaker control via fascia buttons engine support • DSE2157 Output Expansion 245 mm x 184 mm x 51 mm
• Fuel and start outputs • Uses DSE Configuration Suite PC Module 9.6” x 7.2” x 2.0”
configurable when using CAN Software for simplified • DSE2548 LED Expansion Module
PANEL CUT-OUT
• 8 configurable DC outputs configuration 220 mm x 160 mm
8.7” x 6.3”

MAXIMUM PANEL THICKNESS


8 mm
0.3”

-40 °C to +85 °C
RELATED MATERIALS STORAGE TEMPERATURE RANGE

-40 °F to +185 °F
TITLE PART NO’S
DSE8610 MKII Installation Instructions 053-182
DSE8610 MKII Operator Manual 057-254
-30 °C to +70 °C
OPERATING TEMPERATURE RANGE
DSE8610 MKII PC Configuration Suite Manual 057-238
-40 °F to +185 °F

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-204/09/15 (1)