COWI CORBEL DESIGN FOR WATER TANK SLAB 05/11/2018

CORBEL FOR BOTTOM SLAB OF WATER TANK


DESIGN OF CORBEL AT EL+18.266

Grade of Concrete = 40 N/mm2


Yield Stress od Steel fsy = 500 N/mm2
Over all Depth 'h' = 700 mm
b = 600 mm
S
Cover
=
=
350 mm
40 mm
60
Un Fac SF = 1353 KN
a = 166 mm
Assumed Dia of rod = 20
Fac SF Vu = 2029.5 KN
d' = 650 mm
HU(If any horizontal force KN
202.95
is there) =

Step 1 : Ensure S > 0.5


d'
S = 0.54 > 0.50 OK
d'
Step 2 : Ensure a < 0.6
(Check for strut action) d
a = 0.25 <= 0.60 OK
d

Step 3 : Ensure Vu < 4.00 (ζc(max)) (For M 40)


bd
Vu = 5.20 > 4.00 NOT OK
bd

Step 4 : Determination of lever arm


(z/d)2-(r/r+k)*(z/d)+(k/r+k)*(a/d)2=0
K=Fv/(0.88*fck*b*d) = 0.148
a/d = 0.25
Substuting we get,
1 (z/d)2 -0.629 (z/d) + 0.02 = 0
Solving for quadratic equation = -b ± √b2-(4ac)
2a
Hence (z/d) = 0.59 or 0.0394199
Take (z/d) = 0.59
hence z = 383.50 mm
x = 592.23 mm from Z = (d-0.45x)
x/d = 0.92 < 38
No need of compression steel

7
APPENDIX-5
COWI CORBEL DESIGN FOR WATER TANK SLAB 05/11/2018

Step 5 : Resolution of forces


ft =fv(a/z)= 878.48 kN

Step 6 : Area of tension steel SP-16-TABLE A


A st = (ft+fh) Hu = 202.95 KN Stress Strain Stress
fs 0.9 fy 0.00192 324.8
Max strian at failure of steel is = 0.00417 0.95fy 0.00241 342.8
Strain in steel ξs = 0.000341 0.000 266.81109
Compression Steel does not yield and hence work out stress level from table
fs= 266.9 N/mm2
A st = 4051.82 mm2
Min A st = 1560 mm2
Use 9 Y 25 rod 25 @ 75
Area of steel provided = 4417.865 mm2 > 4051.817 mm2 (Needed) Hence ok
And % of steel provided = 1.14 %
Step 6 : Check for min and max steel
100 Ast/(bd) = 1.14 >= the min of 0.4 0.4 OKEY
Also less than max steel percentage of 1.3%
Step 7 : Horizontal Area of shear steel
Asv =1/2(Ast) = 2208.93 mm2
Use 6 no of 4 ` 12 mm dia links in the upper 2/3 depth
Area of links provided = 2714.336 > 2208.93 mm2 (Needed) Hence ok
Spacing = 72.22222 mm

Step 8 : Shear capacity of section


Shear capacity of section for Provided pt% of steel IS:456-TABLE-19
ζc for 1.14 % of steel is 0.464 N/mm
2 100 Ast/(bd) ζc =
As per ,IS 456.cl.40.5.1-Increase design shear strength of concrete is 0.5 0.31
ζc = 2d*ζc = 3.633735 N/mm
2
0.75 0.37
av 1.14 0.4636
Shear capacity of concrete i= 1417.1566 kN [(ζc*b*d ) ]
Shaer reinforcement assume 4 L -Y 12
Shear capacity of steel = 1771.1043 kN
Therfore Total shear capaci 3188.26 kN > 2029.5 Hence ok

9 Y 25
Required 25 @ 75.00
Provided T12@150 C/C

8
APPENDIX-5

You might also like