4

© Siemens AG 2014

Level Measurement

4/2 Overview Continuous level measurement


(continued)
Point level measurement
Accessories for ultrasonic
4/9 Capacitance switches
4/185 – EA aiming devices
4/12 – Pointek CLS100
4/187 – FMS mounting brackets
4/18 – Pointek CLS200 – Standard
4/189 – TS-3 temperature sensor
4/27 – Pointek CLS200 – Digital
4/191 Radar transmitters
4/36 – Pointek CLS200 – Standard and Digital
4/194 – SITRANS Probe LR
4/44 – Pointek CLS300 – Standard
4/198 – SITRANS LR200
4/51 – Pointek CLS300 – Digital
4/207 – SITRANS LR200 Antennas
4/57 – Pointek CLS300 – Standard and Digital
4/210 – SITRANS LR200 Specials
4/64 – Pointek CLS500
4/213 – SITRANS LR250 Horn Antenna
4/80 – Pointek CLS Specials
4/225 – SITRANS LR250 Specials
Vibrating switches
4/226 – SITRANS LR250 threaded PVDF antenna
4/82 – SITRANS LVL100
4/232 – SITRANS LR250 threaded PVDF Specials
4/88 – SITRANS LVL200
4/233 – SITRANS LR250 Flanged
4/104 – SITRANS LVS100
Encapsulated Antenna
4/107 – SITRANS LVS200
4/242 – SITRANS LR250 Flanged
Rotation paddle switches Encapsulated Specials
4/116 – SITRANS LPS200 4/243 – SITRANS LR250 Hygienic
Ultrasonic non-contacting switch Encapsulated Antenna
4/127 – Pointek ULS200 4/268 – SITRANS LR250 Hygienic
Encapsulated Specials
Continuous level measurement
4/269 – SITRANS LR260
4/132 Ultrasonic
4/274 – SITRANS LR460
Ultrasonic transmitters
4/279 – SITRANS LR260/LR460 Specials
4/136 – SITRANS Probe LU
4/280 – SITRANS LR560
4/141 – The Probe
4/285 – SITRANS LR560 Specials
Ultrasonic controllers
4/286 Guided wave radar transmitters
4/144 – SITRANS LUT400 series
4/289 – SITRANS LG series
4/152 – MultiRanger 100/200
Capacitance transmitters
4/156 – HydroRanger 200
4/322 – SITRANS LC300
4/160 – SITRANS LU01 and LU02
4/336 – SITRANS LC500
4/164 – SITRANS LU10
4/359 – SITRANS LC300 and LC500 Specials
4/168 – SITRANS LU AO
Ultrasonic transducers Communication
4/171 – ST-H 4/360 SmartLinx module
4/174 – EchoMax XRS-5 4/361 Dolphin Plus Software
4/178 – EchoMax XPS

You can download all instructions,


catalogs and certificates for SITRANS L
free of charge: www.siemens.com/level

Siemens FI 01 · 2015
© Siemens AG 2014

Level Measurement
Product Overview

■ Overview
Application Device description Page Programming
Software
Point level measurement - Capacitance switches
Powerful range of level switches Pointek CLS100/CLS200/CLS300/CLS500
suitable for a variety of indus-
tries • CLS100: compact 2-wire inverse frequency shift capaci- 4/12 SIMATIC PDM
tance switch for level detection in constricted spaces,
interfaces, solids, liquids, slurries, and foam
• CLS200: a versatile inverse frequency shift capacitance 4/18 SIMATIC PDM
level switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces; digital version
(with PROFIBUS PA) includes a display and provides
additional diagnostic features
• CLS300: inverse frequency shift capacitance level 4/44 SIMATIC PDM
switch with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries,

4 foam and interfaces in demanding conditions where high


pressure and temperatures are present; digital version
(with PROFIBUS PA) includes a display and provides
additional diagnostic features
• CLS500: inverse frequency shift capacitance level 4/64 SIMATIC PDM
switch for detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of high tem-
perature and pressure; HART communication for remote
commissioning
Point level measurement - Vibrating switches
Reliable vibrating point level SITRANS LVL100/LVL200
switches for liquid and slurry
applications across all industries • LVL100: compact vibrating level switch for use in liquid 4/82 -
and slurry applications such as overflow, high, low,
and demand level applications. Also ideal for dry run
protection
• LVL200: advanced vibrating level switch for use in liquid 4/88 -
and slurry applications. Suited for most hazardous area
applications such as: overflow, high, low, demand,
and dry run protection; can also be used for Functional
Safety (SIL 2). Device suitable for use in accordance with
IEC 61508 and IEC 61511

Reliable vibrating point level SITRANS LVS100/LVS200


switches for bulk solids in a wide Vibrating point level switch designed to be impervious
variety of applications at a com- to external vibrations and to provide reliable performance
petitive price in demanding bulk solids applications
• LVS100 4/104 -
• LVS200 4/107 -

Point level measurement - Rotating paddle switch


Reliable rotating point level SITRANS LPS200 4/116 -
switches for bulk solids in a wide • Rotating paddle switch for detection of high, low, and
variety of applications at a com- demand levels for a wide variety of bulk solids industries.
petitive price Unique engineering provides long-lasting reliable perfor-
mance

4/2 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Product Overview

Application Device description Page Programming


Software
Point level measurement - Ultrasonic non-contacting switch
Ultrasonic non-contacting switch Pointek ULS200 4/127 -
with two switch points for level • Rugged design, no moving parts, and virtually mainte-
detection of bulk solids, liquids nance-free
and slurries in a wide variety of
industries • Transducer available in ETFE or PVDF copolymer and
therefore inert to most chemicals

Continuous measurement - Ultrasonic transmitters


2-wire loop powered ultrasonic SITRANS Probe LU 4/136 -
transmitter for level, volume, and • Continuous level measurement up to 12 m (40 ft) range
flow monitoring of liquids in
open channels, storage vessels
and simple process vessels
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression 4

Compact level transmitter with The Probe 4/141 SIMATIC PDM


integrated transducer for accu- • Simple, compact and competitively priced ultrasonic
rate level measurement for liquid level transmitter in several versions for maximum
applications versatility:
- Three-wire system with alarm relay
- Two-wire system with current loop

Continuous measurement - Ultrasonic controllers


The Siemens SITRANS LUT400 SITRANS LUT420/430/440 4/144 SIMATIC PDM
series controllers are compact, In addition to industry leading 1 mm (0.04 inch) accuracy,
single point, long-range ultra- each of the three models in the series are compatible with
sonic controllers for continuous our full range of EchoMax transducers and offer varying
level or volume measurement of degrees of pump, alarm, and other control functionality,
liquids, slurries, and solids, and all from a very compact and easy-to-use interface.
high accuracy monitoring of
open channel flow. • 1 mm accuracy
• HART communications
• Next Generation Sonic Intelligence
Versatile short- to medium-range MultiRanger 100/200 4/152 SIMATIC PDM
ultrasonic single- and dual-ves- • Using non-contacting ultrasonic technology, the control-
sel level controller for virtually ler measures the level in short to medium range applica-
any application in a wide range tions up to 15 m (50 ft) of solids, liquids, or slurries
of industries
• Auto False-Echo Suppression of false echoes

Ultrasonic level controller for up HydroRanger 200 4/156 SIMATIC PDM


to six pumps - control, differen- • An economical, low-maintenance solution delivering
tial control, and open channel control efficiency and productivity needed to meet
flow monitoring today’s exacting standards
• Auto False-Echo Suppression of false echoes

Siemens FI 01 · 2015 4/3


© Siemens AG 2014

Level Measurement
Product Overview

Application Device description Page Programming


Software
Ultrasonic long-range level mon- SITRANS LU01/LU02 4/160 Dolphin Plus
itoring system for liquids and SITRANS LU10 4/164 Dolphin Plus
solids
• Automatic conversion of level into volume for standard or
custom tank shapes
• Easy to install and program
• Optional fieldbus card, e.g. PROFIBUS DP

Output module for SITRANS LU AO 4/168 -


SITRANS LU10 • SITRANS LU AO analog output module provides remote
analog outputs for the measurement points of the
SITRANS LU10 transceiver

4
Continuous measurement - Ultrasonic transducers
ST-H/EchoMax XRS-5
ST-H: ETFE or PVDF transducer • ST-H: The narrow design of the ST-H allows the sensor 4/171 -
for chemicals to be mounted using a 2 inch connection

XRS-5: Standard transducer for • XRS-5: narrow beam angle of only 10°, measuring range 4/174 -
applications to 8 m (26 ft) maximum 8 m (26 ft) for measurement of liquids, solids,
and slurries

Transducers for liquids and bulk EchoMax XPS 4/178 -


solids • XPS series offers versions for various distances up to
XPS series: Hermetically sealed 30 m (100 ft) and up to a maximum temperature of 95 °C
PVDF enclosure for chemical (203 °F)
immunity

Continuous measurement - Radar transmitters


2-wire, 6 GHz pulse radar level SITRANS Probe LR 4/194 SIMATIC PDM
transmitter for continuous moni- • Uni-Construction polypropylene rod antenna standard
toring of liquids and slurries in
storage vessels with nominal • Patented Process Intelligence signal processing
pressure and temperature, • Auto False-Echo Suppression of false echoes
to a range of 20 m (66 ft)

4/4 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Product Overview

Application Device description Page Programming


Software
2-wire, 6 GHz pulse radar level SITRANS LR200 4/198 SIMATIC PDM
transmitter for continuous moni- • Program without opening the lid, even in hazardous AMS
toring of liquids and slurries in areas, using patented infrared IS handheld programmer
storage and process vessels SITRANS DTM
including high temperature and • Special Uni-Construction hermetically sealed polypropyl-
pressure, to a range of 20 m ene rod antenna has integrated threaded connection
(66 ft) • Built-in alphanumeric display with support in four lan-
guages

2-wire, 25 GHz pulse radar level SITRANS LR250 4/213 SIMATIC PDM
transmitter for continuous moni- • Simple operation using the graphical local user interface AMS
toring of liquids and slurries in (LUI)
storage and process vessels SITRANS DTM
including high temperature and • Plug-and-play setup using the intuitive Quick Start
pressure, to a range of 20 m Wizard
(66 ft); antenna designs ideal for
small vessels, low dielectric
media, food & beverages and
• 25 GHz high frequency allows for small horn antennas
and easy mounting in nozzles 4
corrosive/aggressive media • Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppres-
sion of fixed obstructions

2-wire, 25 GHz pulse radar level SITRANS LR260 4/269 SIMATIC PDM
transmitter for continuous moni- • Simple operation using the graphical local user interface
toring of solids and liquids up to (LUI)
30 m (98.4 ft); ideal for measure-
ment in extreme dust and high • Plug-and-play setup using the intuitive Quick Start
temperatures Wizard
• 25 GHz high frequency allows for small horn antennas
and easy mounting in nozzles
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppres-
sion of fixed obstructions

4-wire, 24 GHz FMCW radar SITRANS LR460 4/274 SIMATIC PDM


level transmitter with extremely • Process Intelligence for advanced signal processing and
high signal-to-noise ratio and quick and easy adjustment
advanced signal processing for
continuous monitoring of solids • Self-guided Quick Start Wizard for plug and play start-up
up to 100 m (328 ft); ideal for • 100 m (328 ft) range for long-range and difficult applica-
measurement in extreme dust tions

2-wire, 78 GHz FMCW radar SITRANS LR560 4/280 SIMATIC PDM


level transmitter for continuous • Rugged stainless steel design AMS
monitoring of solids in silos to a
range of 100 m (329 ft) • 78 GHz high frequency provides very narrow beam, SITRANS DTM
virtually no mounting nozzle noise, and optimal reflection
from sloped solids
• Aimer option to direct beam to area of interest, such as
draw point of cone
• Air purge connection is included for self-cleaning of
extremely sticky solids
• Lens antenna is highly resistant to product build-up
• Local display interface (LDI) allows local programming
and diagnostics

Siemens FI 01 · 2015 4/5


© Siemens AG 2014

Level Measurement
Product Overview

Application Device description Page Programming


Software
Continuous measurement - Guided wave radar transmitters
Guided wave radar transmitters SITRANS LG240/250/260/270 4/289 SIMATIC PDM
for short- and medium-range • Measures accurately on materials with dielectric (dK) as
level, level/interface, low as 1.4
and volume measurement
of liquids, slurries, and solids. • Guided wave radar measurement for up to 2 mm
The four LG models are unaf- (0.08 inch) accuracy
fected by changes in process • Measures level, level/interface, and volume of solids,
conditions, high temperatures slurries, and liquids
and pressures, and provide a
wide range of hygienic options. • 4 button programming for quick setup
• Reliable level measurement on harsh applications with
pressure up to 400 bar g (40 000 kPa) and temperatures
as high as 450 °C (842 °F)

4 Continuous level - Capacitance transmitters


For liquids and solids applica- SITRANS LC300 4/322 -
tions, ideal for standard indus- • Sophisticated, but easy-to-adjust microprocessor com-
trial applications in chemical, bined with field-proven probes
hydrocarbon processing, food
and beverage, and mining, • Active shield technology ensures measurements are un-
aggregate and cement indus- affected by vapors, product deposits, dust, and conden-
tries sation

Level and interface transmitter SITRANS LC500 4/336 SIMATIC PDM


for extreme and critical process • Equipped with the HART Smart protocol for remote setup
conditions, such as oil and liquid and calibration
natural gas (LNG), toxic and
aggressive chemicals and • Active shield technology ensures measurements are un-
vapours affected by vapors, product deposits, dust, and conden-
sation

Communication
SmartLinx Module, Dolphin Plus software
• Optional communication modules, SmartLinx, provide 4/360 -
direct digital connection to popular industrial fieldbus
systems
• Dolphin Plus for quick and easy configuring, monitoring, 4/361 -
tuning, and diagnostics of Siemens devices

4/6 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Product Overview
Level Measurement Selector
Continuous Level
Conditions Ultrasonic Radar Guided Wave Capacitance Gravimetric Hydrostatic
Radar pressure
Measurement
Level      
Interface (liquid/liquid)   
Interface (liquid/solid)  
Volume      
Mass  
Flow (open channel)  
Level Applications
Changing density    
Changing dielectric      
Aggressive chemicals      
Pressure/vacuum      4
High temperature     
Cryogenic   
Turbulence      
Steam     
Hydrocarbon vapors/solvents     
Foam      
Build-up      
High viscosity      
Dust     
Solids powders     
Solids granules/pellets     
< 25 mm (1 inch)
Solids > 25 mm (1 inch)   
High angle of repose     
 preferred
 condition dependent

Siemens FI 01 · 2015 4/7


© Siemens AG 2014

Level Measurement
Product Overview
Level Measurement Selector
Point Level
Conditions Vibration Capacitance Paddle Ultrasonic
Measurement
Level    
Interface (liquid/liquid) 
Interface (liquid/solid)  
Volume
Mass
Flow (open channel)
Level Applications
Changing density    
Changing dielectric    
Aggressive chemicals    

4   
Pressure/vacuum
High temperature   
Cryogenic 
Turbulence   
Steam   
Hydrocarbon vapors/solvents  
Foam   
Build-up    
High viscosity    
Dust    
Solids powders    
Solids granules/pellets < 25 mm (1 inch)    
Solids > 25 mm (1 inch)    
High angle of repose    
 preferred
 condition dependent

4/8 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Capacitance

■ Overview ■ Mode of operation


Introduction Common Terms
Inverse frequency shift capacitance point level and material Capacitance
detection switches are designed to withstand the harsh environ-
ments of high pressure and high temperature applications. The property of a system of conductors and dielectrics that per-
mits the storage of electricity when a potential difference exists
Inverse Frequency Technology between the conductors. Its value is expressed as the ratio of a
quantity of electricity to a potential difference and the unit is a
Siemens inverse frequency shift capacitance devices incorpo- Farad.
rate a unique frequency-based approach to level measurement.
The capacitance units monitor the effect of capacitance based Capacitor
on frequency change. The relationship between capacitance A device in a circuit that has the potential to store an electric
and frequency is inverse. Because small level changes result in charge. Typically a capacitor has two conductors or electrodes
a large frequency change, the result is excellent resolution and separated by a layer of a non-conducting material called a
accuracy. dielectric. With the conductors on opposite sides of the dielec-
Principle of Operation tric layer oppositely charged by a source of voltage, the electri-
cal energy of the charged system is stored in the polarized
Inverse frequency shift capacitance devices require two compo-
nents: a reference electrode of a variable capacitor and the
dielectric.
4
measurement electrode. In capacitive level measurement, Dielectric constant
the environment (typically the vessel wall) acts as the reference The ability of a dielectric to store electrical potential energy
electrode, while the probe supplies the measurement electrode. under the influence of an electric field. This is measured by a
The dielectric is composed of the vessel contents and, if the ratio which compares the capacitance of a condenser with the
measurement electrode is insulated, the insulating layer. material as dielectric to its capacitance with a vacuum/dry air as
dielectric: the dielectric constant of air is 1.
Operating principles
Dielectric = contents plus insulation Active shield
(non-conductive contents)
The portion of the probe isolated from the active measurement
Dielectric = insulation section. The sensor signal is connected to the active shield por-
(conductive contents)
tion of the probe, eliminating the electrical potential difference
between the shield and the measurement section. So, the shield
portion of the probe near the process connection is not affected
by changes in vapor concentration, material buildup, dust,
or condensation.

Probe
dia.

Internal (Insulation)
vessel wall Probe
sleeve

Internal vessel diameter

Inverse frequency shift capacitance operation


Capacitance is affected by the surface area of the electrodes,
the separation distance between the electrodes and the dielec-
tric constant of the vessel contents. The dielectric constant is the
measure of a material’s ability to store energy. The relative
dielectric constant of air (vacuum) is 1; all other materials have
a higher value.

Siemens FI 01 · 2015 4/9


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Capacitance

■ Technical specifications
Point Level Measurement
Criteria Pointek CLS100 Pointek CLS200 Pointek CLS300 Pointek CLS500
Typical applications Liquids, slurries, powders, Liquids, slurries, powders, Liquids, slurries, powders, Water in oil level, foam or
granules, applications in granules, foam, food, and granules, relatively high pres- liquid/ foam level, glycol
constricted spaces pharmaceuticals, petrochemi- sure and temperature, hazard- regenerators, high-pressure
cals ous areas coalescers
Max. length 100 mm (4 inch) Rod: 5.5 m (18 ft) Rod: 1 m (40 inch) Rod: 1 m (40 inch)
including sensor Cable: up to 30 m (98 ft) Cable: 25 m (82 ft)
Process temperature Stainless steel process • -40 ... +85 °C • -40 ... +200 °C • -50 ... +200 °C
(Temperature ratings are pres- connection: (-40 ... +185 °F) (-40 ... +392 °F) (-58 ... +392 °F)
sure dependent. • -30 ... +100 °C • With thermal • HT version: • HT version:
See Pressure/Temperature (22 ...+212 °F) isolator: -40 ... +400 °C -60 ... +400 °C
curves for respective Fully Synthetic (PPS process -40 ... +125 °C (-40 ... +752 °F) (-76 ... +752 °F)
product.) connection): (-40 ... +257 °F)
• -10 ... +100 °C
(14 ... 212 °F)

4 Process pressure Up to 10 bar g


(Pressure ratings are tempera- (146 psi g)
ture dependent.
Rod versions:
• Up to 25 bar g (365 psi g)
Up to 35 bar g
(511 psi g)
• Up to 150 bar g
(2 175 psi g)
Cable version:
See Pressure/Temperature • Up to 10 bar g (146 psi g)
curves for respective
product.)
Output Stainless steel cable or enclo- Standard: Standard: • 4 ... 20/20 ... 4 mA 2-wire
sure version: • 1 SPDT Form C relay, • 1 SPDT Form C relay, current loop
• 4 ... 20/20 ... 4 mA solid-state switch solid-state switch • Solid-state switch
2-wire current loop Digital: Digital:
• Solid-state output • Solid-state switch included • Solid-state switch included
Fully-synthetic version (PPS)
• Relay output
Communications Standard: Standard: HART, SIMATIC PDM
• 3 LED indicators • 3 LED indicators compatible
Digital: Digital:
• PROFIBUS PA; • PROFIBUS PA;
SIMATIC PDM compatible SIMATIC PDM compatible
Power Standard: Standard: Standard: • 12 ... 33 V DC
Specifications • 12 ... 33 V DC • 12 ... 250 V AC/DC, • 12 ... 250 V AC/DC, • 3.6 ... 22 mA/
Intrinsically Safe 0 ... 60 Hz, 2 W max. 0 ... 60 Hz, 2 W max. 22 ... 3.6 mA
(Stainless steel version only): Digital: Digital: (2-wire current loop)
• 10 ... 30 V DC • Bus voltage: • Bus voltage:
12 ... 30 V DC, 12 ... 30 V DC,
IS version IS version
12 ... 24 V DC 12 ... 24 V DC
• Current consumption: • Current consumption:
12.5 mA 12.5 mA
Approvals Stainless steel cable or enclo- CSA, FM, CE, ATEX, RCM, CSA, FM, CE, ATEX, RCM, CE, CSA, FM, ATEX, RCM,
sure version: Lloyds Register, WHG, Lloyds Register, WHG, Lloyds Register, Bureau Veri-
CE, CSA, FM, ATEX, RCM, Vlarem II Vlarem II tas, Current Signaling accord-
Lloyds Register, WHG ing to NAMUR NE 43
Fully-synthetic version (PPS):
CSA, FM

4/10 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Capacitance

■ Application

Capacitance Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: ( )

E-mail: Fax: ( ) 4
Tank/Vessel Information (Supply sketch where possible) Sketch attached

Type: Storage Tank construction: Dimensions:


Metallic Non-metallic Height: m/ft
Process
Agitated top, bottom or side
Width/Diameter: m/ft
Separator
Pressure:
FPSO Normal: Critical Information
(Floating Processing
Storage and Offloading) Maximum (relief): Nozzle Length: cm/inch
Tank top: Open Tank bottom: Sloped Mounting: Top Mount Nozzle Diameter: cm/inch
Flat Flat Side Mount
Conical Conical Pipe Mount
Parabolic Parabolic

Process Data
Material being measured: Liquid Solid Slurry

Material temperature: Norm: °C/°F Max: °C/°F

Measurement type: Point level


Constant dielectric: No Yes DK Value
Continuous level

Upper material: DK Value


Interface level
Lower material: DK Value

Process pressure: Min. Max. Atmospheric steam: No Yes

Coating build-up: No Yes Conductive material: No Yes DK Value

Installation (indicate all that apply)

Power available:

Outputs required: Communications

4 ... 20 mA Relay Solid state HART / 4 ... 20 mA PROFIBUS PA

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-770R5

Capacitance Application Questionnaire

Siemens FI 01 · 2015 4/11


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100

■ Overview ■ Configuration
Installation

Standpipes

20 (0.79) max.
≥ 50 (2)

4
Wall restriction
Pointek CLS100 is a compact 2-wire inverse frequency shift
capacitance switch for level and material detection in con-
stricted spaces, interfaces, solids, liquids, slurries and foam,
with the ability to tune out build-up on probe.

■ Benefits
• Easy installation with verification by built-in LED 50 (2)
• Low maintenance with no moving parts min.

• Sensitivity adjustment
• Integrated cable or PBT enclosure versions available
• Intrinsically Safe, Dust Ignition Proof, and General Purpose

50 (2)
options available

■ Application
Pointek CLS100’s short insertion length of 100 mm (4 inch) and
versatility in various applications and in vessels or pipes makes Pointek CLS100 installation, dimensions in mm (inch)
it a good replacement for traditional capacitance sensors.
Its advanced tip-sensing technology provides accurate, repeat-
able switchpoint performance. The PPS (Polyphenylene sulfide)
probe [optional PVDF (Polyvinylidene Fluoride)] is chemically
resistant with an effective process operating temperature
range from -30 to +100 °C (-22 to +212 °F) (7ML5501),
and -10 to +100 °C (14 to 212 °F) (7ML5610). The fully potted
design ensures reliability in a vibrating environment such as
agitated tanks up to 4 g. When used with a SensGuard protec-
tion cover, the CLS100 is protected from shearing, impact,
and abrasion in tough primary processes.
The Pointek CLS100 is available in three versions. The integral
cable version has a stainless steel process connection and
probe options of PPS or PVDF. The fully synthetic version has a
thermoplastic polyester enclosure with a PPS process connec-
tion combined with a PPS probe. The standard enclosure version
has a thermoplastic polyester enclosure with a stainless steel
process connection in combination with a PPS or PVDF probe.
• Key Applications: liquids, slurries, powders, granules,
food and pharmaceuticals, chemicals, hazardous areas

4/12 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100

■ Technical specifications
Stainless steel Fully synthetic Stainless steel Fully synthetic
process connection process connection process connection process connection
(integral cable or (enclosure version (integral cable or (enclosure version
enclosure version) only) enclosure version) only)
(7ML5501) (7ML5610) (7ML5501) (7ML5610)
Mode of operation Sensor length (nominal) 100 mm (4 inch) 100 mm (4 inch)
Measuring principle Inverse frequency shift Inverse frequency shift Process connection Connection: 316L PPS process connec-
capacitive level capacitive level material of probe/ stainless steel; tion and PPS sensor
detection detection wetted parts3) Process seal: FKM (Uni-Construction)
(optional FFKM);
Input Sensor: PPS
(optional PVDF)4)
Measured variable Change in picoFarad Change in picoFarad
(pF) (pF) Connection Internal 5-point terminal Removable internal
(Enclosure version) block, 5-point terminal block,
Output ½" NPT wiring entrance, ½" NPT wiring entrance,
M20x1.5 optional M20 x 1.5 optional
Output signal
Connection 4 conductors, 1 m Not applicable
• Alarm output 4 ... 20/20 ... 4 mA 4 ... 20/20 ... 4 mA (Integral cable version) (3.3 ft), 0.5 mm²

4
2-wire loop 2-wire loop (22 AWG), shielded,
1)
• Switch output Solid-state: Max. switching voltage: polyester jacket
30 V DC/30 V AC, 60 V DC/30 V AC Process connection ¾" NPT [(Taper), ¾" NPT [(Taper),
max. 82 mA Max. switching current: ANSI/ASME B1.20.1] ANSI/ASME B1.20.1]
1A R 1" [(BSPT), R 1" [(BSPT),
• Fail-safe mode Min. or max. Min. or max. EN 10226/PT (JIS-T), EN 10226/PT (JIS-T),
JIS B 0203] JIS B 0203]
Accuracy
G 1" [(BSPP),
Repeatability 2 mm (0.08 inch) 2 mm (0.08 inch) EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Rated operating
conditions2) Power supply
• Standard 12 ... 33 V DC 12 ... 33 V DC
Installation conditions
• Intrinsically Safe 10 ... 30 V DC Not applicable
• Location Indoor/outdoor Indoor/outdoor
(Intrinsically Safe
Ambient conditions barrier required)
• Ambient temperature -30 ... +85 °C -10 ... +85 °C Certificates and • General: CE, CSA, FM, • General: CSA, FM
(-22 ... +185 °F) (14 ... 185 °F) approvals RCM
• Installation category I I • Marine: Lloyds Regis-
• Pollution degree 4 4 ter of Shipping, cate-
gories ENV1, ENV2,
Medium conditions and ENV5
• Relative dielectric Min. 1.5 Min. 1.5 Dust Ignition Proof
constant r (barrier required):
• Process temperature -30 ... +100 °C -10 ... +100 °C CSA/FM Class II and
(-22 ... +212 °F) (14 ... 212 °F) III, Div. 1, Groups E, F,
• Pressure (vessel) -1 ... +10 bar g -1 ... +10 bar g G T4
(-14.6 ... +146 psi g), (-14.6 ... +146 psi g), • Intrinsically Safe (barri-
nominal2) nominal er required): CSA/FM
Class I, II and III, Div. 1,
• Degree of protection Groups A, B, C, D, E, F,
- Enclosure version IP68/Type 4/NEMA 4 IP68/Type 4/NEMA 4 G T4
ATEX II 1 GD 1/2GD
- Integral cable IP65/Type 4/NEMA 4 Not applicable
EEx ia IIC T4 to T6
version
T107 °C
• Cable inlet ½" NPT ½" NPT • Overfill protection:
(M20x1.5 optional) (M20x1.5 optional) WHG (Germany)
Design 1)
When synthetic process connection version (7ML5610) is used in wet
Enclosure/Integral cable Fully synthetic version locations, switching voltage of the relay is limited to 35 V DC/16 V AC.
version 2)
When operation is in areas classified as hazardous, observe restrictions
Material according to relevant certificate.
See also Pressure/Temperature curves on page 4/16.
• Body Thermoplastic polyester Thermoplastic polyester
3)
(Enclosure version) For Caustic Materials please contact ceg.smpi@siemens.com
• Lid Transparent thermoplas- Transparent thermoplas- http://www.siemens.com/automation/support-request for alternative
(Enclosure version) tic polycarbonate (PC) tic polycarbonate (PC) O Rings
4)
• Integrated cable body 316L stainless steel Not applicable When FFKM O-ring (Option A22) is selected, process temperature is
(Integral cable restricted to -20 °C (-4 °F).
version)

Siemens FI 01 · 2015 4/13


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS100, stainless steel process 7ML5501- Accessories
connection
0 7777 SensGuard, ¾" NPT (PPS) 7ML1830-1DL
Compact 2-wire inverse frequency shift capacitance Only available for CLS100 with ¾" NPT thread
switch for level and material detection in constricted
spaces, interfaces, solids, liquids, slurries and foam, SensGuard, R 1" (BSPT) (PPS) 7ML1830-1DM
with the ability to tune out build-up on probe. Only available for CLS100 with ¾" NPT thread
Click on the Article No. for the online configura- Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
tion in the PIA Life Cycle Portal. one text line, suitable for enclosures
Process connection Siemens Intrinsically Safe Barrier (DC powered), 7NG4124-0AA00
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ A ATEX II 1 G EEx ia
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ E ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ J diameter 6 ... 12 mm (0.24 ... 0.47 inch)
JIS B 0202] -40 ... +100 °C (-40 ... +212 °F), IP68
(General Purpose)
Approvals
M20 x 1.5 cable gland, PA polyamide, 7ML1830-1JC
General Purpose: CE, CSA, FM, RCM ¢ A ATEX II 2G EEx e II, fits cable diameter
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, ¢ C 7 ... 12 mm (0.28 ... 0.47 inch), -20 ... +70 °C

4 E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to (-4 ... +158 °F), IP68 (General Purpose)
T6 T107 °C 1)
CSA/FM Class II and III, Div. 1, Groups E, F, G1) ¢ G Selection and Ordering data Article No.
Device version Pointek CLS100, PPS process connection 7ML5610-
Integral cable version (PPS probe) ¢ 1 Compact 2-wire inverse frequency shift 0 7777
capacitance switch for level and material detection
Enclosure version (PPS probe), ½" NPT cable inlet ¢ 3 in constricted spaces, interfaces, solids, liquids,
Integral cable version with PVDF probe body ¢ 5 slurries and foam, with the ability to tune out build-
Enclosure version with PVDF probe body ¢ 6 up on foam.
(½" NPT cable inlet) Click on the Article No. for the online configura-
Enclosure version (PPS probe), M20 x 1.5 cable ¢ 7 tion in the PIA Life Cycle Portal.
inlet
Enclosure version with PVDF probe body, ¢ 8 Process connection (PPS)
M20 x 1.5 cable inlet ¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ A
(PPS probe body)
Overfill protection R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ B
Not required ¢ 0 (PPS probe body)
Required ¢ 1
Approvals
1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe General Purpose: CSA, FM ¢ D
protection
Versions/Options
¢ We can offer shorter delivery times for configurations designated with the Enclosure version, PPS process connection, ¢ 1
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. ½" NPT cable inlet
Enclosure version, PPS process connection, ¢ 2
M20 x 1.5
Selection and Ordering data Order code
Further designs Overfill protection
Not required ¢ 0
Please add "-Z" to Article No. and specify Order Required ¢ 1
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm ¢ Y17 Selection and Ordering data Order code
(0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 20 characters) specify Further designs
in plain text
Please add "-Z" to Article No. and specify Order
FFKM seal O-ring1) ¢ A22 code(s).
Inspection Certificate Type 3.1 per EN 10204 ¢ C12 Acrylic coated, stainless steel tag [13 x 45 mm ¢ Y17
(0.5 x 1.75 inch)]: Measuring-point number/
Operating Instructions Article No. identification (max. 20 characters) specify
in plain text
Quick start manual, multi-language A5E32146158
Note: due to ATEX regulations one Quick start manual FFKM seal O-ring1) A22
is included with every product. Inspection Certificate Type 3.1 per EN 10204 C12
This device is shipped with the Siemens Milltronics
manual DVD containing ATEX Quick Starts and Operating Instructions Article No.
Operating Instructions.
Quick start manual, multi-language A5E32146158
1) Note: due to ATEX regulations one Quick start manual
See Temperature restriction on page 4/16
is included with every product.
¢ We can offer shorter delivery times for configurations designated with the This device is shipped with the Siemens Milltronics
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. manual DVD containing ATEX Quick Starts and
Operating Instructions.
Accessories
SensGuard, ¾" NPT (PPS) 7ML1830-1DL
Only available for CLS100 with ¾" NPT thread
SensGuard, R 1" (BSPT) (PPS) 7ML1830-1DM
Only available for CLS100 with ¾" NPT thread
Tag, stainless steel, 12 x 45 mm, (0.47 x 1.77 inch) 7ML1930-1AC
one text line, suitable for enclosures
1) See Temperature restriction on page 4/16
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/14 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100

■ Options
Optional SensGuard
Internal thread ¾" NPT
(1.26)

(1.26)
32

32
Process
Process connection
connection R 1" (BSPT)
¾" NPT
91 (3.6)

91 (3.6)
70 (2.75)

70 (2.75)

Optional SensGuard, dimensions in mm (inch) 4

Siemens FI 01 · 2015 4/15


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100

■ Characteristic curves
Pressure/temperature curve
CLS100
Threaded process connections
(7ML5501)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


atmospheric

4 -22 ºF 14 ºF
(-30 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C

Pointek CLS100 Process Pressure/Temperature derating curves

■ Dimensional drawings
Integral cable version Enclosure version 80 (3.2)

Ground post Power LED (green) Cable inlet ½" NPT


36 (1.4) nominal* (optional M20x1.5)
65 (2.6)
Power LED (green) Sensitivity trimpot 1
2

Cable relief 3
4
5

Sensor status
Output status LED (yellow)
Sensitivity trimpot LED (red) Terminal block
Cable Ø 5 (0.2) Sensor status Output status ground lug
Trimpot cap LED (yellow) LED (red)
72.5 (2.9)
(2.0)
50

Process connection
Process connection
204 (8.0)
120 (4.7)

120 (4.7)
98 (3.9)
nominal

nominal
98 (3.9)

*Some G thread configurations deviate from this size.

Pointek CLS100, dimensions in mm (inch)

4/16 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS100

■ Schematics
Integral Cable Version - Non Intrinsically Safe only

LOW/HIGH Alarm
White Polarity as required
White
for
desired operation
Black

Red 12 ... 33 V DC

4/20 mA Loop Alarm


White

White

Black

Red
Rmax = Vsupply - 10 V
20 mA
V supply
12 ... 33 V DC
Solid State Switch Version
White
Solid state switch, 4
30 V DC/AC
White
(peak) 82 mA (max)
Black

Red V supply
12 ... 33 V DC

Enclosure and Fully Synthetic Version


Terminal operations Cable equivalent
1 mA current loop (+V or -V) Red wire
2 mA current loop (+V or -V) Black wire
3 ground Cable shield
4 Solid state switch/relay* White wire
5 Solid state switch/relay* White wire

* Switch/relay normally open in unpowered state


* Relay not available on Pointek CLS100 IS version (7ML5501)
Note:
When driving an inductive load (for example, an external relay), a protection diode
must be connected in the correct polarity to prevent possible switch damage due to
inductive spikes generated by switching the inductor (please refer to instruction
manual). Intrinsically Safe Models - please follow local regulations and area
classifications; refer to instruction manual for more details.

Pointek CLS100 connections

Siemens FI 01 · 2015 4/17


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS200 (standard version) is a versatile inverse fre- falling material.
quency shift capacitance level and material detection switch
with optional rod/cable choices and configurable output.
CLS200 is ideal for detection of liquids, solids, slurries, foam and
interfaces and has the ability to tune out build-up on the probe.

■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
Avoid areas where material build up occurs.
• Insensitive to product buildup due to high frequency oscil-
lation
• 3 LED indicators for sensor status, output status, and power

■ Application
Pointek CLS200 standard version has 3 LED indicators with
basic relay and solid-state switch alarms. Universal switch for
solids/liquids and interface.
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 250 V AC/DC). When used with thermal M
in
isolator, the stainless steel and PPS (PVDF optional) materials
.5
0
used in the probe construction provide a temperature rating up (2
)
to 125 °C (257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency,
and it can be set to detect before contact or on contact with the
probe. The CLS200 operates independently of the tank wall or
pipe so it does not require an external reference electrode for
Install probe at least 50 (2) from tank wall.
level detection in a non-conductive vessel such as concrete or
plastic (EMC regulations applicable in some regions).
Pointek CLS200 installation, dimensions in mm (inch)
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas

4/18 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard

■ Technical specifications
Mode of operation Design
Measuring principle Inverse frequency shift capacitive Material
level detection • Enclosure Epoxy-coated aluminum with gasket
• Optional thermal isolator 316L stainless steel
Input
Connection Removable terminal block,
Measured variable Change in picoFarad (pF) max. 2.5 mm²
Output Degree of protection IP65/Type 4/NEMA 4 (optional IP68)
Cable inlet 2 x M20x1.5 thread
Output signal (option: 2 x ½" NPT conduit entry
• Relay output 1 SPDT Form C relay including 1 plugged entry)
- Max. contact voltage • 30 V DC Power supply 12 ... 250 V AC/DC, 0 ... 60 Hz
• 250 V AC max. 2 W
- Max. contact current • 5 A DC
• 8 A AC Certificates and approvals
- Max. switching capacity 150 W DC General Purpose CSA, FM, CE, RCM
2 000 VA AC Dust Ignition Proof ATEX II 1/2 D T100 °C
- Time delay (ON and/or OFF) 1 ... 60 s Flameproof Enclosure With IS Probe ATEX II 1 G EEx d[ia] IIC T6...T4

• Solid-state output Dust Ignition Proof with IS Probe


ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Groups E, F, G
4
- Output Galvanically isolated
- Protection Against reversed polarity (bipolar) CSA/FM Class III T4
- Max. switching voltage • 30 V DC Explosion Proof Enclosure CSA/FM Class I, Div. 1,
• 30 V peak AC With IS Probe Groups A, B, C, D
CSA/FM Class II, Div. 1,
- Max. load current 82 mA Groups E, F, G
- Voltage drop < 1 V, typical at 50 mA CSA/FM Class III T4
Marine Lloyds Register of Shipping,
- Time delay (pre or post switching) 1 ... 60 s Categories ENV1, ENV2 and ENV5
Rated operating conditions1) Overfill Protection WHG (Germany)
VLAREM II
Installation conditions Others Pattern Approval (China)
• Location Indoor/outdoor
1)
When operation is in areas classified as hazardous, observe restrictions
Ambient conditions according to relevant certificate.
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) See also Pressure/Temperature curves on page 4/37.
• Installation category II 2)
Thermal isolator is used if process connection temperature exceeds 85 °C
• Pollution degree 4 (185 °F)
3)
Medium conditions Liquids, bulk solids, slurries and Pressure rating of process seal is temperature dependent.
interfaces See Pressure/Temperature curves on page 4/37.
• Relative dielectric constant r Min. 1.5
• Process temperature
- Without thermal isolator -40 ... +85 °C (-40 ... +185 °F)2)
- With thermal isolator -40 ... +125 °C (-40 ... +257 °F)
• Process pressure (rod version) -1 ... +25 bar g
(-14.6 ... +365 psi g) (nominal)
• Process pressure (cable version)3) -1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
• Process pressure (sliding coupling -1 ... +10 bar g
version) (-14.6 ... +150 psi g) (nominal)
Electromagnetic Compatibility To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.

Siemens FI 01 · 2015 4/19


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Design: Probe
Rod version Sanitary version Cable version Sliding Coupling version
Max. length 5 500 mm (216.53 inch) 5 500 mm (216.53 inch) 30 000 mm (1 181.1 inch) 5 500 mm (216.53 inch)
liquids and slurries
5 000 mm (196.85 inch)
solids (under loads)
Process connection R ¾", 1", 1½", 2" sanitary fitting clamp R ¾", 1", 1¼", 1½" [(BSPT), R ¾", 1", 1¼", 1½" [(BSPT),
1¼", 1½" [(BSPT), 316L stainless steel EN 10226/PT (JIS-T), EN 10226/PT (JIS-T),
EN 10226/PT (JIS-T), JIS B 0203] JIS B 0203]
JIS B 0203] ¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1]
¾", 1", G ¾", 1", 1½" [(BSPP), G ¾", 1",
1¼", 1½" NPT EN ISO 228-1/PF (JIS-P), 1½" [(BSPP),
[(Taper), ANSI/ASME B1.20.1] JIS B 0202] EN ISO 228-1/PF (JIS-P),
316L stainless steel JIS B 0202]
G ¾", 1", ASME/EN flange
1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]

4
316L stainless steel
ASME/EN flange
Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene 316L stainless steel
optional PFA coated1) (FEP) cable with stainless
steel core
Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF)
O-ring seal material FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2)
3)
Thermal isolator Optional Optional Optional Optional
Extension User selected length User selected length Cable extension User selected length
1) PFA coating (7ML5634 and 7ML5644) has 120 micron thickness.
2) For Caustic Materials please contact ceg.smpi@siemens.com for alternative O-Rings
3) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F).

4/20 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard

■ Selection and Ordering data Article No. ■ Selection and Ordering data Article No.
Pointek CLS200 - Standard - Rod Version with 7ML5630- Pointek CLS200 - Standard - Rod Version with 7ML5630-
Threaded or Flanged process connection 77 7 77 - 77 7 0 Threaded or Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/ and material detection switch with optional rod/
cable choices and configurable output. CLS200 is cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam, ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out build- and interfaces, and has the ability to tune out build-
up on the probe. up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, 210 ... 1 000 mm (8.27 ... 39.37 inch) ¢ M
Threaded, 316L stainless steel Extended rod, 1 001 ... 2 000 mm ¢ N
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A (39.41 ... 78.74 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B Extended rod, 2 001 ... 3 000 mm ¢ P
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C (78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm ¢ Q
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D (118.15 ... 157.48 inch)
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A Extended rod, 4 001 ... 5 000 mm ¢ R
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢
¢ 1B
1D
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm ¢ S 4
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢ 3A (196.89 ... 216.53 inch)
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢ 3B Thermal isolator
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D Without thermal isolator ¢ 0
JIS B 0202] With thermal isolator [for process connection ¢ 1
temperatures over 85 °C (185 °F)]
Welded flange, 316L stainless steel, raised face
Remote mount electronics and
1" ASME, 150 lb ¢ 5A mounting bracket
1" ASME, 300 lb 5B
1" ASME, 600 lb 5C With 2 m (79 inch) of cable1) ¢ 2
1½" ASME, 150 lb ¢ 5D With 5 m (197 inch) of cable1) ¢ 3
1½" ASME, 300 lb 5E Wetted seals
1½" ASME, 600 lb 5F FKM ¢ 0
2" ASME, 150 lb ¢ 5G FFKM [for process temperatures above -20 °C (-4 °F)]¢ 1
2" ASME, 300 lb 5H Probe material
2" ASME, 600 lb 5J 316L stainless steel with PPS probe body ¢ 0
3" ASME, 150 lb ¢ 5K 316L stainless steel with PVDF probe body ¢ 1
3" ASME, 300 lb 5L Approvals
3" ASME, 600 lb 5M
Dust Ignition Proof: ¢ C
4" ASME, 150 lb ¢ 5N CE, RCM, ATEX II 1/2 D T100 °C
4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
Welded flange, 316L stainless steel, ATEX II 1/2 D T100 °C
Type A flat faced
DN 25, PN 16 ¢ 6A Flameproof Enclosure with IS Probe, ¢ E
with WHG approval:
DN 25, PN 40 6B
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
DN 40, PN 16 ¢ 6C
ATEX II 1/2 D T100 °C
DN 40, PN 40 6D
Dust Ignition Proof with IS Probe: ¢ F
DN 50, PN 16 ¢ 6E
CSA/FM Class II, Div. 1, Groups E, F, G
DN 50, PN 40 6F
CSA/FM Class III T4
DN 80, PN 16 ¢ 6G
Explosion Proof Enclosure with IS Probe: ¢ G
DN 80, PN 40 6H
CSA/FM Class I, Div. 1, Groups A, B, C, D
DN 100, PN 16 ¢ 6J CSA/FM Class II, Div. 1, Groups E, F, G
DN 100, PN 40 6K CSA/FM Class III T4
(Note: Flange bolting patterns and facings General Purpose (CSA, FM) ¢ H
dimensionally correspond to the applicable
General Purpose (CE, RCM) ¢ J
ASME B16.5 or EN 1092-1 standard.)
General Purpose (CSA, FM, CE, RCM) ¢ K
Probe length (length from flange face)
with WHG approval
(threaded lengths include process thread)
Enclosure and lid
Note: No Y01 needed in Order code for
Aluminum epoxy coated
standard lengths
Compact [threaded 120 mm (4.72 inch), ¢ A 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Flanged 98 mm (3.86 inch)] 2 x M20 x 1.5 cable inlet IP65 ¢ B
Extended rod, 250 mm (9.84 inch) ¢ B 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
Extended rod, 350 mm (13.78 inch) ¢ C 2 x M20 x 1.5 cable inlet IP68 ¢ D
Extended rod, 500 mm (19.69 inch) ¢ D 1)
Extended rod, 750 mm (29.53 inch) ¢ E Available with Approvals options F ... H
Extended rod, 1 000 mm (39.37 inch) ¢ F ¢ We can offer shorter delivery times for configurations designated with the
Extended rod, 1 250 mm (49.21 inch) ¢ G Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Extended rod, 1 350 mm (53.15 inch) ¢ H
Extended rod, 1 500 mm (59.06 inch) ¢ J
Extended rod, 1 750 mm (68.90 inch) ¢ K
Extended rod, 2 000 mm (78.74 inch) ¢ L

Siemens FI 01 · 2015 4/21


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Pointek CLS200 - Standard - Cable Version with 7ML5631-
Threaded or Flanged process connection 7 7 7 77 - 77 7 0
Please add "-Z" to Article No. and specify Order Versatile inverse frequency shift capacitance level
code(s). and material detection switch with optional rod/
Total insertion length: enter the total insertion length ¢ Y01 cable choices and configurable output. CLS200 is
in plain text description ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out build-
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15 up on the probe.
Measuring-point number/identification Click on the Article No. for the online configura-
(max. 27 characters) specify in plain text tion in the PIA Life Cycle Portal.
Manufacturer's test certificate: M to DIN 55350, ¢ C11 Process connection
Part 18 and ISO 9000 Threaded, 316L stainless steel
Inspection Certificate Type 3.1 per EN 10204 ¢ C12 ¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B
Operating Instructions 1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C
Note: The Operating Instructions should be See page 4/36 1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D
ordered as a separate line on the order. R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A
This device is shipped with the Siemens Milltronics R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B

4 manual DVD containing the ATEX Quick Start and


manual library.
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢
1D
3A
Accessories See page 4/36 G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢ 3B
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D
¢ We can offer shorter delivery times for configurations designated with the JIS B 0202]
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb ¢ 5A
1" ASME, 300 lb 5B
1" ASME, 600 lb 5C
1½" ASME, 150 lb ¢ 5D
1½" ASME, 300 lb 5E
1½" ASME, 600 lb 5F
2" ASME, 150 lb ¢ 5G
2" ASME, 300 lb 5H
2" ASME, 600 lb 5J
3" ASME, 150 lb ¢ 5K
3" ASME, 300 lb 5L
3" ASME, 600 lb 5M
4" ASME, 150 lb ¢ 5N
4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16 ¢ 6A
DN 25, PN 40 6B
DN 40, PN 16 ¢ 6C
DN 40, PN 40 6D
DN 50, PN 16 ¢ 6E
DN 50, PN 40 6F
DN 80, PN 16 ¢ 6G
DN 80, PN 40 6H
DN 100, PN 16 ¢ 6J
DN 100, PN 40 6K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch), length ¢ A
can be determined by customer on assembly1)
Extended cable, 6 000 mm (236.22 inch), length ¢ B
can be determined by customer on assembly1)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 5 000 mm ¢ C
(19.69 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm ¢ D
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm ¢ E
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm ¢ F
(590.59 ... 787.4 inch)
Extended cable, 20 001 ... 25 000 mm ¢ G
(787.44 ... 984.25 inch)
Extended cable, 25 001 ... 30 000 mm ¢ H
(984.29 ... 1 181.1 inch)

4/22 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS200 - Standard - Cable Version with 7ML5631- Further designs
Threaded or Flanged process connection 77 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Please add "-Z" to Article No. and specify Order
and material detection switch with optional rod/ code(s).
cable choices and configurable output. CLS200 is Total insertion length: enter the total insertion length ¢ Y01
ideal for detection of liquids, solids, slurries, foam, in plain text description
and interfaces, and has the ability to tune out build-
up on the probe. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Thermal isolator Measuring-point number/identification
(max. 27 characters) specify in plain text
Without thermal isolator ¢ 0
Manufacturer's test certificate: M to DIN 55350, ¢ C11
With thermal isolator [for process connection ¢ 1 Part 18 and ISO 9000
temperatures over 85 °C (185 °F)]
Remote mount electronics and mounting Inspection Certificate Type 3.1 per EN 10204 ¢ C12
bracket Operating Instructions
With 2 m (79 inch) of cable2) ¢ 2
Note: The Operating Instructions should be See page 4/36
With 5 m (197 inch) of cable2) ¢ 3 ordered as a separate line on the order.
Wetted seals This device is shipped with the Siemens Milltronics
FKM and PTFE
FFKM and PTFE [for process temperatures above ¢
¢ 0
1
manual DVD containing the ATEX Quick Start and
manual library. 4
-20 °C (-4 °F)] Accessories See page 4/36
Probe material
¢ We can offer shorter delivery times for configurations designated with the
FEP jacketed cable with PPS probe body ¢ 0 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
FEP jacketed cable with PVDF probe body ¢ 1
Approvals
Dust Ignition Proof: ¢ C
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, ¢ E
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe: ¢ F
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe: ¢ G
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM) ¢ H
General Purpose (CE, RCM) ¢ J
General Purpose (CSA, FM, CE, RCM) ¢ K
with WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
2 x M20 x1.5 cable inlet, IP65 ¢ B
2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
2 x M20 x1.5 cable inlet, IP68 ¢ D
1)
Sensor detached to allow customer to set desired cable length
2)
Available with Approvals options F ... H
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/23


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Standard - Rod with 7ML5632- Pointek CLS200 - Standard - Rod with 7ML5632-
Sanitary process connection 77777 - 777 0 Sanitary process connection 77777 - 777 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/ and material detection switch with optional rod/
cable choices and configurable output. CLS200 is cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam, ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out build- and interfaces, and has the ability to tune out build-
up on the probe. up on the probe.
Click on the Article No. for the online configura- Approvals
tion in the PIA Life Cycle Portal. Dust Ignition Proof: ¢ C
Process connection CE, RCM, ATEX II 1/2 D T100 °C
Sanitary 316L stainless steel Flameproof Enclosure with IS Probe: ¢ D
1" sanitary fitting clamp ¢ 8A CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
1½" sanitary fitting clamp 8B ATEX II 1/2 D T100 °C
2" sanitary fitting clamp 8C Flameproof Enclosure with IS Probe, ¢ E
2½" sanitary fitting clamp ¢ 8D with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
4
3" sanitary fitting clamp 8E
ATEX II 1/2 D T100 °C
(Note: Sanitary connection dimensionally
corresponds to the applicable ISO 2852 standard) Dust Ignition Proof with IS Probe: ¢ F
CSA/FM Class II, Div. 1, Groups E, F, G
Probe length (length from process connection CSA/FM Class III T4
face)
Explosion Proof Enclosure with IS Probe: ¢ G
Note: No Y01 needed in Order code for
CSA/FM Class I, Div. 1, Groups A, B, C, D
standard lengths
CSA/FM Class II, Div. 1, Groups E, F, G
Compact 98 mm (3.86 inch) ¢ A CSA/FM Class III T4
Extended rod, 250 mm (9.84 inch) ¢ B
Extended rod, 350 mm (13.78 inch) ¢ C General Purpose (CSA, FM) ¢ H
General Purpose (CE, RCM) ¢ J
Extended rod, 500 mm (19.69 inch) ¢ D
Extended rod, 750 mm (29.53 inch) ¢ E General Purpose (CSA, FM, CE, RCM) ¢ K
Extended rod, 1 000 mm (39.37 inch) ¢ F with WHG approval
Extended rod, 1 250 mm (49.21 inch) ¢ G Enclosure and lid
Extended rod, 1 350 mm (53.15 inch) ¢ H Aluminum epoxy coated
Extended rod, 1 500 mm (59.06 inch) ¢ J 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Extended rod, 1 750 mm (68.90 inch) ¢ K 2 x M20x1.5 cable inlet, IP65 ¢ B
Extended rod, 2 000 mm (78.74 inch) ¢ L 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
2 x M20x1.5 cable inlet, IP68 ¢ D
Add Order code Y01 and plain text:
"Insertion length ... mm" 1)
Available with Approvals options F ... H
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch) ¢ M
Extended rod, 351 ... 1 000 mm (13.78 ... 39.37 inch) ¢ N ¢ We can offer shorter delivery times for configurations designated with the
Extended rod, 1 001 ... 2 000 mm ¢ P Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm ¢ Q Selection and Ordering data Order code
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm ¢ R Further designs
(118.15 ... 157.48 inch) Please add "-Z" to Article No. and specify Order
Extended rod, 4 001 ... 5 000 mm ¢ S code(s).
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm ¢ T Total insertion length: enter the total insertion length ¢ Y01
(196.89 ... 216.53 inch) in plain text description
Thermal isolator Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Without thermal isolator ¢ 0 Measuring-point number/identification
With thermal isolator [for process connection ¢ 1 (max. 27 characters) specify in plain text
temperatures over 85 °C (185 °F)] Manufacturer's test certificate: M to DIN 55350, ¢ C11
Remote mount electronics and Part 18 and ISO 9000
mounting bracket Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Remote mount electronics with 2 m (79 inch) ¢ 2
of cable1) Operating Instructions
Remote mount electronics with 5 m (197 inch) ¢ 3
Note: The Operating Instructions should be See page 4/36
of cable1) ordered as a separate line on the order.
Wetted seals This device is shipped with the Siemens Milltronics
FKM ¢ 0 manual DVD containing the ATEX Quick Start and
FFKM ¢ 1 manual library.
[for process temperatures above -20 °C (-4 °F)] Accessories See page 4/36
Probe material
316L stainless steel with PPS probe body ¢ 0 ¢ We can offer shorter delivery times for configurations designated with the
316L stainless steel with PVDF probe body ¢ 1 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/24 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Standard - Sliding Coupling 7ML5633- Pointek CLS200 - Standard - Sliding Coupling 7ML5633-
with Threaded process connection 77 7 77 - 77 7 0 with Threaded process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/ and material detection switch with optional rod/
cable choices and configurable output. CLS200 is cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam, ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out build- and interfaces, and has the ability to tune out build-
up on the probe. up on the probe.
Click on the Article No. for the online configura- Approvals
tion in the PIA Life Cycle Portal. Dust Ignition Proof: ¢ C
Process connection CE, RCM, ATEX II 1/2 D T100 °C
Threaded, 316L stainless steel Flameproof Enclosure with IS Probe: ¢ D
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T4,
1" NPT [(Taper), ANSI/ASME B1.20.1] 0B ATEX II 1/2 D T100 °C
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0C Flameproof Enclosure with IS Probe, ¢ E
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D with WHG approval:
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1A CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,

4
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1B ATEX II 1/2 D T100 °C
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1D Dust Ignition Proof with IS Probe: ¢ F
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3A CSA/FM Class II, Div. 1, Groups E, F, G
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3B CSA/FM Class III T4
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3D
Explosion Proof Enclosure with IS Probe: ¢ G
Probe length (length from flange face) CSA/FM Class I, Div. 1, Groups A, B, C, D
(threaded lengths include process thread) CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Note: No Y01 needed in Order code for
standard lengths General Purpose (CSA, FM) ¢ H
Extended rod, 350 mm (13.78 inch) ¢ C General Purpose (CE, RCM) ¢ J
Extended rod, 500 mm (19.69 inch) ¢ D General Purpose (CSA, FM, CE, RCM) ¢ K
Extended rod, 750 mm (29.53 inch) ¢ E with WHG approval
Extended rod, 1 000 mm (39.37 inch) ¢ F Enclosure and lid
Extended rod, 1 250 mm (49.21 inch) ¢ G Aluminum epoxy coated
Extended rod, 1 350 mm (53.15 inch) ¢ H 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Extended rod, 1 500 mm (59.06 inch) ¢ J 2 x M20x1.5 cable inlet, IP65 ¢ B
Extended rod, 1 750 mm (68.90 inch) ¢ K 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
Extended rod, 2 000 mm (78.74 inch) ¢ L 2 x M20x1.5 cable inlet, IP68 ¢ D
Add Order code Y01 and plain text: 1)
Available with Approvals options F ... H
"Insertion length ... mm"
Extended rod, 350 ... 1 000 mm ¢ M ¢ We can offer shorter delivery times for configurations designated with the
(13.78 ... 39.37 inch) Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Extended rod, 1 001 ... 2 000 mm ¢ N
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm ¢ P Selection and Ordering data Order code
(78.78 ... 118.11 inch) Further designs
Extended rod, 3 001 ... 4 000 mm ¢ Q
(118.15 ... 157.48 inch) Please add "-Z" to Article No. and specify Order
Extended rod, 4 001 ... 5 000 mm ¢ R code(s).
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm ¢ S Total insertion length: enter the total insertion length ¢ Y01
(196.89 ... 216.53 inch) in plain text description
Thermal isolator Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Without thermal isolator ¢ 0 Measuring-point number/identification
With thermal isolator [for process connection ¢ 1 (max. 27 characters) specify in plain text
temperatures over 85 °C (185 °F)]
Manufacturer's test certificate: M to DIN 55350, ¢ C11
Remote mount electronics and Part 18 and ISO 9000
mounting bracket
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
With 2 m (79 inch) of cable1) ¢ 2
With 5 m (197 inch) of cable1) ¢ 3 Operating Instructions
Wetted seals Note: The Operating Instructions should be See page 4/36
FKM and PTFE ¢ 0 ordered as a separate line on the order.
FFKM and PTFE [for process temperatures above ¢ 1 This device is shipped with the Siemens Milltronics
-20 °C (-4 °F)] manual DVD containing the ATEX Quick Start and
Probe material manual library.
316L stainless steel with PPS probe body ¢ 0
316L stainless steel with PVDF probe body ¢ 1 Accessories See page 4/36
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/25


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Standard - PFA Coated Rod 7ML5634- Pointek CLS200 - Standard - PFA Coated Rod 7ML5634-
with PFA Coated Flanged process connection 77 7 77 - 77 7 0 with PFA Coated Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional rod/ and material detection switch with optional rod/
cable choices and configurable output. CLS200 is cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam, ideal for detection of liquids, solids, slurries, foam,
and interfaces, and has the ability to tune out build- and interfaces, and has the ability to tune out build-
up on the probe. up on the probe.
Click on the Article No. for the online configura- Thermal isolator
tion in the PIA Life Cycle Portal. Without thermal isolator 0
Process connection With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]
Welded flange, 316L stainless steel, raised face
Remote mount electronics and
1" ASME, 150 lb 5A mounting bracket
1" ASME, 300 lb 5B
1" ASME, 600 lb 5C With 2 m (79 inch) of cable 2
With 5 m (197 inch) of cable 3
1½" ASME, 150 lb 5D
1½" ASME, 300 lb 5E Wetted seals
4 1½" ASME, 600 lb
2" ASME, 150 lb
5F
5G
FKM
FFKM [for process temperatures above
0
1
2" ASME, 300 lb 5H -20 °C (-4 °F)]
2" ASME, 600 lb 5J Probe material
3" ASME, 150 lb 5K PFA Coated 316L stainless steel with 0
3" ASME, 300 lb 5L PPS probe body
3" ASME, 600 lb 5M PFA Coated 316L stainless steel with 1
PVDF probe body
4" ASME, 150 lb 5N
4" ASME, 300 lb 5P Approvals
4" ASME, 600 lb 5Q Dust Ignition Proof with IS Probe: F
Welded flange, 316L stainless steel, CSA/FM Class II, Div. 1, Groups E, F, G
Type A flat faced CSA/FM Class III T4
DN 25, PN 16 6A Explosion Proof Enclosure with IS Probe: G
DN 25, PN 40 6B CSA/FM Class I, Div. 1, Groups A, B, C, D
DN 40, PN 16 6C CSA/FM Class II, Div. 1, Groups E, F, G
DN 40, PN 40 6D CSA/FM Class III T4
DN 50, PN 16 6E General Purpose (CSA, FM) H
DN 50, PN 40 6F
Enclosure and lid
DN 80, PN 16 6G Aluminum epoxy coated
DN 80, PN 40 6H
DN 100, PN 16 6J 2 x ½" NPT via adapter - cable inlet, IP65 A
DN 100, PN 40 6K 2 x M20x1.5 cable inlet, IP65 B
2 x ½" NPT via adapter - cable inlet, IP68 C
(Note: Flange bolting patterns and facings 2 x M20x1.5 cable inlet, IP68 D
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.) Selection and Ordering data Order code
Probe length (length from flange face) Further designs
(threaded lengths include process thread)
Note: No Y01 needed in Order code for Please add "-Z" to Article No. and specify Order
standard lengths code(s).
Compact 98 mm (3.86 inch) A Total insertion length: enter the total insertion length Y01
Extended rod, 250 mm (9.84 inch) B in plain text description
Extended rod, 350 mm (13.78 inch) C
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Extended rod, 500 mm (19.69 inch) D Measuring-point number/identification
Extended rod, 750 mm (29.53 inch) E (max. 27 characters) specify in plain text
Extended rod, 1 000 mm (39.37 inch) F
Manufacturer's test certificate: M to DIN 55350, C11
Extended rod, 1 250 mm (49.21 inch) G
Part 18 and ISO 9000
Extended rod, 1 350 mm (53.15 inch) H
Inspection Certificate Type 3.1 per EN 10204 C12
Extended rod, 1 500 mm (59.06 inch) J
Extended rod, 1 750 mm (68.90 inch) K Operating Instructions
Extended rod, 2 000 mm (78.74 inch) L
Note: The Operating Instructions should be See page 4/36
Add Order code Y01 and plain text: ordered as a separate line on the order.
"Insertion length ... mm" This device is shipped with the Siemens Milltronics
Extended rod, 200 ... 1 000 mm (7.87 ... 39.37 inch) M manual DVD containing the ATEX Quick Start and
Extended rod, 1 001 ... 2 000 mm N manual library.
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm P Accessories See page 4/36
(78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm Q
(118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm R
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm S
(196.89 ... 216.53 inch)

4/26 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS200 (digital version) is a versatile inverse frequency falling material.
shift capacitance level and material detection switch with
optional rod/cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam and interfaces
and has the ability to tune out build-up on the probe. The digital
version includes PROFIBUS PA, an LCD display, and advanced
diagnostic features.

■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity and/or condensation
• High chemical resistance Avoid areas where material build up occurs.
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscil-
lation
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)

■ Application
M
in
Pointek CLS200 digital version provides an integral LCD display .5
for stand-alone use, and also provides PROFIBUS PA communi- 0
(2
)
cation (Profile version 3.0, Class B) for connection to a network.
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 30 V DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating
up to 125 °C (257 °F) on the process wetted portion of the probe. Install probe at least 50 (2) from tank wall.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency, Pointek CLS200 installation, dimensions in mm (inch)
and it can be set to detect before contact or on contact with the
probe. The menu-driven setup allows precise control of the
switch point signal damping and alarm functions.
When connected to the PROFIBUS network, advanced diagnos-
tics and set up using SIMATIC PDM are possible.
The CLS200 operates independently of the tank wall or pipe so it
does not require an external reference electrode for level detec-
tion in a non-conductive vessel such as concrete or plastic
(EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas

Siemens FI 01 · 2015 4/27


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital

■ Technical specifications
Mode of operation Power supply
Measuring principle Inverse frequency shift capacitive Bus voltage Standard: 12 ... 30 V DC
level detection Intrinsically Safe: 12 ... 24 V DC
Input Current consumption 12.5 mA

Measured variable Change in picoFarad (pF) Certificates and approvals


General Purpose CSA, FM, CE, RCM
Output Dust Ignition Proof ATEX II 1/2 D T100 °C
Output signal Dust Ignition Proof with IS Probe CSA/FM Class II, Div. 1,
• Solid-state output Groups E, F, G
- Output Galvanically isolated CSA/FM Class III T4
- Protection Against reversed polarity (bipolar) Flameproof Enclosure with IS Probe ATEX II 1/2 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
- Max. switching voltage • 30 V (DC)
• 30 V peak (AC) Explosion Proof with IS Probe CSA/FM Class I,
Div. 1, Groups A, B, C, D
- Max. load current 82 mA CSA/FM Class II, Div. 1,
- Voltage drop < 1 V, typical at 50 mA Groups E, F, G

4
- Time delay (ON and/or OFF) Programmable by user (0 ... 100 s) CSA/FM Class III T4
• Fail-safe mode Min. or max. Intrinsically Safe4) ATEX II 1 G EEx ia IIC T6 ... T4
• Connection Removable terminal block ATEX II 1/2 D IP6X T100 °C
CSA/FM Class I, Div. 1,
Rated operating conditions1) Groups A, B, C, D
CSA/FM Class II, Div. 1,
Installation conditions
Groups E, F, G
• Location Indoor/outdoor CSA/FM Class III T4
Ambient conditions Non-incendive CSA/FM Class I, Div. 2,
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) Groups A, B, C, D
CSA/FM Class II, Div. 2,
• Installation category II Groups F, G
• Pollution degree 4 CSA/FM Class III T4 or T6
Medium conditions Liquids, bulk solids, slurries and Non-Sparking ATEX II 3 G Ex nA II T6...T4
interfaces ATEX II 2 D IP6X T100 °C
• Relative dielectric constant r Min. 1.5 Marine Lloyds Register of Shipping,
• Process temperature Categories ENV1, ENV2 and ENV5
Others Pattern Approval (China)
- Without thermal isolator -40 ... +85 °C (-40 ... +185 °F)2)
- With thermal isolator -40 ... +125 °C (-40 ... +257 °F) Communication PROFIBUS PA
(IEC 61158 CPF3 CP3/2)
• Process pressure (rod version) -1 ... +25 bar g Bus physical layer:
(-14.6 ... +365 psi g) (nominal) IEC 61158-2 MBP (IS)
• Process pressure (cable version) 3) -1 ... +10 bar g Device profile: PROFIBUS PA
(-14.6 ... +150 psi g) (nominal) profile for Process Control
• Process pressure -1 ... +10 bar g Devices Version 3.0, Class B
(sliding coupling version) (-14.6 ... +150 psi g) (nominal) FISCO field device
Design 1)
When operation is in areas classified as hazardous, observe restrictions
• Material according to relevant certificate.
See also Pressure/Temperature curves on page 4/37.
- Enclosure Epoxy-coated aluminum with gasket 2)
Thermal isolator is used if process connection temperature exceeds 85 °C
- Optional thermal isolator 316L stainless steel
(185 °F)
• Connection Removable terminal block, 3)
max. 2.5 mm² Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves on page 4/37.
• Degree of protection IP65/Type 4/NEMA 4 (optional IP68)
4)
• Cable inlet 2 x M20x1.5 thread Barrier or Intrinsically Safe power supply required for Intrinsically Safe
(option: 2 x ½" NPT conduit entry protection
including 1 plugged entry)
Electromagnetic Compatibility To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.

4/28 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Design: Probe
Rod version Sanitary version Cable version Sliding Coupling version
Max. length 5 500 mm (216.53 inch) 5 500 mm (216.53 inch) 30 000 mm (1 181.1 inch) 5 500 mm (216.53 inch)
liquids and slurries
5 000 mm (196.85 inch)
solids (under loads)
Process R ¾", 1" , 1¼", 1½" [(BSPT), 1½", 2" sanitary fitting clamp R ¾", 1", 1¼", 1½" [(BSPT), R ¾", 1", 1¼", 1½ inch [(BSPT),
connection EN 10226/PT (JIS-T), 316L stainless steel EN 10226/PT (JIS-T), EN 10226/PT (JIS-T),
JIS B 0203] JIS B 0203] JIS B 0203]
¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP), G ¾", 1", 1½" [(BSPP), G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P), EN ISO 228-1/PF (JIS-P), EN ISO 228-1/PF (JIS-P),
JIS B 0202] JIS B 0202] JIS B 0202]
316L stainless steel 316L stainless steel
ASME/EN flange ASME/EN flange
Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene 316L stainless steel
optional PFA coated1) (FEP) cable with stainless
steel core
Sensor wetted parts
O-ring seal material
PPS (optional PVDF)
FKM (optional FFKM)2)
PPS (optional PVDF)
FKM (optional FFKM)2)
PPS (optional PVDF)
FKM (optional FFKM)2)
PPS (optional PVDF)
FKM (optional FFKM)2)
4
Thermal isolator3) Optional Optional Optional Optional
Extension User selected length User selected length Cable extension User selected length
1) PFA coating (7ML5634 and 7ML5644) has 120 micron thickness
2) For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-Rings
3) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F).

Siemens FI 01 · 2015 4/29


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - Rod 7ML5640- Pointek CLS200 - Digital - Rod 7ML5640-
with Threaded or Flanged process connection 77 7 77 - 77 7 0 with Threaded or Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, 210 ... 1 000 mm (8.27 ... 39.37 inch) ¢ M
Threaded, 316L stainless steel Extended rod, 1 001 ... 2 000 mm ¢ N
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A (39.41 ... 78.74 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B Extended rod, 2 001 ... 3 000 mm ¢ P
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C (78.78 ... 118.11 inch)
Extended rod, 3 001 ... 4 000 mm ¢ Q
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D (118.15 ... 157.48 inch)
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A Extended rod, 4 001 ... 5 000 mm ¢ R
4 R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
¢
¢
1B
1D
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm ¢ S
JIS B 0203] (196.89 ... 216.53 inch)
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]¢ 3A Thermal isolator
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B Without thermal isolator ¢ 0
JIS B 0202] With thermal isolator [for process connection ¢ 1
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D temperatures over 85 °C (185 °F)]
JIS B 0202] Remote mount electronics and
Welded flange, 316L stainless steel, raised face mounting bracket
With 2 m (79 inch) of cable ¢ 2
1" ASME, 150 lb ¢ 5A
With 5 m (197 inch) of cable ¢ 3
1" ASME, 300 lb 5B
1" ASME, 600 lb 5C Wetted seals
FKM ¢ 0
1½" ASME, 150 lb ¢ 5D
FFKM [for process temperatures above ¢ 1
1½" ASME, 300 lb 5E
-20 °C (-4 °F)]
1½" ASME, 600 lb 5F
Probe material
2" ASME, 150 lb ¢ 5G
316L stainless steel with PPS probe body ¢ 0
2" ASME, 300 lb 5H
316L stainless steel with PVDF probe body ¢ 1
2" ASME, 600 lb 5J
Approvals
3" ASME, 150 lb ¢ 5K
Non-Sparking: ¢ B
3" ASME, 300 lb 5L CE, RCM, ATEX II 3 G Ex nA II T6...T4,
3" ASME, 600 lb 5M ATEX II 2 D IP6X T100 °C
4" ASME, 150 lb ¢ 5N Dust Ignition Proof: ¢ C
4" ASME, 300 lb 5P CE, RCM, ATEX II 1/2 D T100 °C
4" ASME, 600 lb 5Q
Intrinsically Safe:1) ¢ D
Welded flange, 316L stainless steel, CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
Type A flat faced ATEX II 1/2 D IP6X T100 °C
DN 25, PN 16 ¢ 6A
DN 25, PN 40 6B Flameproof Enclosure with IS Probe: ¢ E
DN 40, PN 16 ¢ 6C CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
DN 40, PN 40 6D
DN 50, PN 16 ¢ 6E Non-incendive: ¢ F
DN 50, PN 40 6F CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
DN 80, PN 16 ¢ 6G CSA/FM Class III T4 or T6
DN 80, PN 40 6H
Dust Ignition Proof with IS Probe: ¢ G
DN 100, PN 16 ¢ 6J CSA/FM Class II, Div. 1, Groups E, F, G
DN 100, PN 40 6K CSA/FM Class III T4
(Note: Flange bolting patterns and facings Intrinsically Safe:1) ¢ H
dimensionally correspond to the applicable CSA/FM Class I, Div. 1, Groups A, B, C, D
ASME B16.5 or EN 1092-1 standard.) CSA/FM Class II, Div. 1, Groups E, F, G
Probe length (length from flange face) CSA/FM Class III T4
(threaded lengths include process thread) Explosion Proof with IS Probe: ¢ J
Note: No Y01 needed in Order code for CSA/FM Class I, Div. 1, Groups A, B, C, D
standard lengths CSA/FM Class II, Div. 1, Groups E, F, G
Compact [threaded 120 mm (4.72 inch), ¢ A CSA/FM Class III T4
Flanged 98 mm (3.86 inch)] General Purpose (CSA, FM) ¢ K
Extended rod, 250 mm (9.84 inch) ¢ B
Extended rod, 350 mm (13.78 inch) ¢ C General Purpose (CE, RCM) ¢ L
Extended rod, 500 mm (19.69 inch) ¢ D
Extended rod, 750 mm (29.53 inch) ¢ E
Extended rod, 1 000 mm (39.37 inch) ¢ F
Extended rod, 1 250 mm (49.21 inch) ¢ G
Extended rod, 1 350 mm (53.15 inch) ¢ H
Extended rod, 1 500 mm (59.06 inch) ¢ J
Extended rod, 1 750 mm (68.90 inch) ¢ K
Extended rod, 2 000 mm (78.74 inch) ¢ L

4/30 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - Rod 7ML5640- Pointek CLS200 - Digital - Cable with 7ML5641-
with Threaded or Flanged process connection 77 7 77 - 77 7 0 Threaded or Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Enclosure and lid Click on the Article No. for the online configura-
Aluminum epoxy coated tion in the PIA Life Cycle Portal.
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A Process connection
2 x M20x1.5 cable inlet, IP65 ¢ B Threaded, 316L stainless steel
2 x ½" NPT via adapter - cable inlet, IP68 ¢ C ¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A
2 x M20x1.5 cable inlet, IP68 ¢ D 1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B
1) 1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D
protection
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A

4
¢ We can offer shorter delivery times for configurations designated with the R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D
JIS B 0203]
Selection and Ordering data Order code G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3A
JIS B 0202]
Further designs G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B
Please add "-Z" to Article No. and specify Order JIS B 0202]
code(s). G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D
JIS B 0202]
Total insertion length: enter the total insertion length ¢ Y01 Welded flange, 316L stainless steel, raised face
in plain text description
1" ASME, 150 lb ¢ 5A
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15 1" ASME, 300 lb 5B
Measuring-point number/identification 1" ASME, 600 lb 5C
(max. 27 characters) specify in plain text 1½" ASME, 150 lb ¢ 5D
Manufacturer's test certificate: M to DIN 55350, ¢ C11 1½" ASME, 300 lb 5E
Part 18 and ISO 9000 1½" ASME, 600 lb 5F
2" ASME, 150 lb ¢ 5G
Inspection Certificate Type 3.1 per EN 10204 ¢ C12 2" ASME, 300 lb 5H
Operating Instructions 2" ASME, 600 lb 5J
Note: The Operating Instructions should be See page 4/36 3" ASME, 150 lb ¢ 5K
ordered as a separate line on the order. 3" ASME, 300 lb 5L
This device is shipped with the Siemens Milltronics 3" ASME, 600 lb 5M
manual DVD containing the ATEX Quick Start and 4" ASME, 150 lb ¢ 5N
manual library. 4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q
Accessories See page 4/36
Welded flange, 316L stainless steel,
¢ We can offer shorter delivery times for configurations designated with the Type A flat faced
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. DN 25, PN 16 ¢ 6A
DN 25, PN 40 6B
DN 40, PN 16 ¢ 6C
DN 40, PN 40 6D
DN 50, PN 16 ¢ 6E
DN 50, PN 40 6F
DN 80, PN 16 ¢ 6G
DN 80, PN 40 6H
DN 100, PN 16 ¢ 6J
DN 100, PN 40 6K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)

Siemens FI 01 · 2015 4/31


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - Cable with 7ML5641- Pointek CLS200 - Digital - Cable with 7ML5641-
Threaded or Flanged process connection 77 7 77 - 77 7 0 Threaded or Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Probe length (length from flange face) Enclosure and lid
(threaded lengths include process thread) Aluminum epoxy coated
Note: No Y01 needed in Order code for 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
standard lengths 2 x M20x1.5 cable inlet, IP65 ¢ B
Extended cable, 3 000 mm (118.11 inch), length ¢ A 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
can be determined by customer on assembly 2 x M20x1.5 cable inlet, IP68 ¢ D
Extended cable, 6 000 mm (236.22 inch), length ¢ B 1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
can be determined by customer on assembly
protection
Add Order code Y01 and plain text:
¢ We can offer shorter delivery times for configurations designated with the
4
"Insertion length ... mm"
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Extended cable, 500 ... 5 000 mm ¢ C
(19.69 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm ¢ D Selection and Ordering data Order code
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm ¢ E Further designs
(393.74 ... 590.55 inch) Please add "-Z" to Article No. and specify Order
Extended cable, 15 001 ... 20 000 mm ¢ F code(s).
(590.59 ... 787.40 inch)
Extended cable, 20 001 ... 25 000 mm ¢ G Total insertion length: enter the total insertion length ¢ Y01
(787.44 ... 984.25 inch) in plain text description
Extended cable, 25 001 ... 30 000 mm ¢ H
(984.29 ... 1 181.10 inch) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Thermal isolator (max. 27 characters) specify in plain text
Without thermal isolator ¢ 0
With thermal isolator [for process connection ¢ 1 Manufacturer's test certificate: M to DIN 55350, ¢ C11
temperatures over 85 °C (185 °F)] Part 18 and ISO 9000
Remote mount electronics and Inspection Certificate Type 3.1 per EN 10204 ¢ C12
mounting bracket
Operating Instructions
With 2 m (79 inch) of cable ¢ 2
With 5 m (197 inch) of cable ¢ 3 Note: The Operating Instructions should be See page 4/36
Wetted seals ordered as a separate line on the order.
FKM and PTFE ¢ 0 This device is shipped with the Siemens Milltronics
FFKM and PTFE [for process temperatures ¢ 1 manual DVD containing the ATEX Quick Start and
above -20 °C (-4 °F)] manual library.
Probe material Accessories See page 4/36
FEP jacketed cable with PPS probe body ¢ 0
FEP jacketed cable with PVDF probe body ¢ 1 ¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Approvals
Non-Sparking: ¢ B
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: ¢ C
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1) ¢ D
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe: ¢ E
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive: ¢ F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe: ¢ G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Intrinsically Safe:1) ¢ H
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe: ¢ J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM) ¢ K
General Purpose (CE, RCM) ¢ L

4/32 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - Rod with 7ML5642- Pointek CLS200 - Digital - Rod with 7ML5642-
Sanitary process connection 77 7 77 - 777 0 Sanitary process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Click on the Article No. for the online configura- Non-incendive: ¢ F
tion in the PIA Life Cycle Portal. CSA/FM Class I, Div. 2, Groups A, B, C, D
Process connection CSA/FM Class II, Div. 2, Groups F, G
Sanitary 316L stainless steel CSA/FM Class III T4 or T6
1" sanitary fitting clamp ¢ 8A Dust Ignition Proof with IS Probe: ¢ G
1½" sanitary fitting clamp 8B CSA/FM Class II, Div. 1, Groups E, F, G
2" sanitary fitting clamp 8C CSA/FM Class III T4
2½" sanitary fitting clamp ¢ 8D Intrinsically Safe:1) ¢ H
3" sanitary fitting clamp 8E CSA/FM Class I, Div. 1, Groups A, B, C, D
(Note: Sanitary connection dimensionally CSA/FM Class II, Div. 1, Groups E, F, G
corresponds to the applicable ISO 2852 standard.)
Probe length (length from process connection face)
CSA/FM Class III T4
Explosion Proof with IS Probe: ¢ J
4
CSA/FM Class I, Div. 1, Groups A, B, C, D
Note: No Y01 needed in Order code for CSA/FM Class II, Div. 1, Groups E, F, G
standard lengths CSA/FM Class III T4
Compact 98 mm (3.86 inch) ¢ A
Extended rod, 250 mm (9.84 inch) ¢ B General Purpose (CSA, FM) ¢ K
Extended rod, 350 mm (13.78 inch) ¢ C General Purpose (CE, RCM) ¢ L
Extended rod, 500 mm (19.69 inch) ¢ D Enclosure and lid
Extended rod, 750 mm (29.53 inch) ¢ E Aluminum epoxy coated
Extended rod, 1 000 mm (39.37 inch) ¢ F
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Extended rod, 1 250 mm (49.21 inch) ¢ G 2 x M20x1.5 cable inlet, IP65 ¢ B
Extended rod, 1 350 mm (53.15 inch) ¢ H 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
Extended rod, 1 500 mm (59.06 inch) ¢ J 2 x M20x1.5 cable inlet, IP68 ¢ D
Extended rod, 1 750 mm (68.90 inch) ¢ K 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe
Extended rod, 2 000 mm (78.74 inch) ¢ L protection
Add Order code Y01 and plain text:
"Insertion length ... mm" ¢ We can offer shorter delivery times for configurations designated with the
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch) ¢ M Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Extended rod, 351 ... 1 000 mm ¢ N
(13.82 ... 39.37 inch)
Extended rod, 1 001 ... 2 000 mm ¢ P Selection and Ordering data Order code
(39.41 ... 78.74 inch) Further designs
Extended rod, 2 001 ... 3 000 mm ¢ Q Please add "-Z" to Article No. and specify Order
(78.78 ... 118.11 inch) code(s).
Extended rod, 3 001 ... 4 000 mm ¢ R Total insertion length: enter the total insertion length ¢ Y01
(118.15 ... 157.48 inch) in plain text description
Extended rod, 4 001 ... 5 000 mm ¢ S
(157.52 ... 196.85 inch) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Extended rod, 5 001 ... 5 500 mm ¢ T (max. 27 characters) specify in plain text
(196.89 ... 216.53 inch)
Manufacturer's test certificate: M to DIN 55350, ¢ C11
Thermal isolator Part 18 and ISO 9000
Without thermal isolator ¢ 0
With thermal isolator [for process connection ¢ 1 Inspection Certificate Type 3.1 per EN 10204 ¢ C12
temperatures over 85 °C (185 °F)] Operating Instructions
Remote mount electronics and Note: The Operating Instructions should be See page 4/36
mounting bracket ordered as a separate line on the order.
With 2 m (79 inch) of cable ¢ 2 This device is shipped with the Siemens Milltronics
With 5 m (197 inch) of cable ¢ 3 manual DVD containing the ATEX Quick Start and
Wetted seals manual library.
FKM ¢ 0 Accessories See page 4/36
FFKM [for process temperatures above -20 °C (-4 °F)]¢ 1
Probe material ¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
316L stainless steel with PPS probe body ¢ 0
316L stainless steel with PVDF probe body ¢ 1
Approvals
Non-Sparking: ¢ B
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: ¢ C
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1) ¢ D
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe: ¢ E
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C

Siemens FI 01 · 2015 4/33


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - Rod with Sliding 7ML5643- Pointek CLS200 - Digital - Rod with Sliding 7ML5643-
coupling with Threaded process connection 77 7 77 - 77 7 0 coupling with Threaded process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Click on the Article No. for the online configura- Flameproof Enclosure with IS Probe: ¢ E
tion in the PIA Life Cycle Portal. CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
Process connection ATEX II 1/2 D T100 °C
Threaded, 316L stainless steel Non-incendive: ¢ F
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A CSA/FM Class I, Div. 2, Groups A, B, C, D
1" NPT [(Taper), ANSI/ASME B1.20.1] 0B CSA/FM Class II, Div. 2, Groups F, G
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0C CSA/FM Class III T4 or T6
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D Dust Ignition Proof with IS Probe: ¢ G
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1A CSA/FM Class II, Div. 1, Groups E, F, G

4
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1B CSA/FM Class III T4
R 1½" [(BSPT), EN 10226/PT (JIS-T), 1D Intrinsically Safe:1) ¢ H
JIS B 0203] CSA/FM Class I, Div. 1, Groups A, B, C, D
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3A CSA/FM Class II, Div. 1, Groups E, F, G
JIS B 0202] CSA/FM Class III T4
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3B Explosion Proof with IS Probe: ¢ J
JIS B 0202] CSA/FM Class I, Div. 1, Groups A, B, C, D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3D CSA/FM Class II, Div. 1, Groups E, F, G
JIS B 0202] CSA/FM Class III T4
Probe length (length from flange face) General Purpose (CSA, FM) ¢ K
(threaded lengths include process thread) General Purpose (CE, RCM) ¢ L
Note: No Y01 needed in Order code for Enclosure and lid
standard lengths Aluminum epoxy coated
Extended rod, 350 mm (13.78 inch) ¢ C 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Extended rod, 500 mm (19.69 inch) ¢ D 2 x M20x1.5 cable inlet, IP65 ¢ B
Extended rod, 750 mm (29.53 inch) ¢ E 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
Extended rod, 1 000 mm (39.37 inch) ¢ F 2 x M20x1.5 cable inlet, IP68 ¢ D
Extended rod, 1 250 mm (49.21 inch) ¢ G 1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
Extended rod, 1 350 mm (53.15 inch) ¢ H protection
Extended rod, 1 500 mm (59.06 inch) ¢ J ¢ We can offer shorter delivery times for configurations designated with the
Extended rod, 1 750 mm (68.90 inch) ¢ K Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Extended rod, 2 000 mm (78.74 inch) ¢ L
Add Order code Y01 and plain text:
"Insertion length ... mm"
Selection and Ordering data Order code
Extended rod, 350 ... 1 000 mm ¢ M
(13.82 ... 39.37 inch) Further designs
Extended rod, 1 001 ... 2 000 mm ¢ N Please add "-Z" to Article No. and specify Order
(39.41 ... 78.74 inch) code(s).
Extended rod, 2 001 ... 3 000 mm ¢ P Total insertion length: enter the total insertion length ¢ Y01
(78.78 ... 118.11 inch) in plain text description
Extended rod, 3 001 ... 4 000 mm ¢ Q Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
(118.15 ... 157.48 inch) Measuring-point number/identification
Extended rod, 4 001 ... 5 000 mm ¢ R (max. 27 characters) specify in plain text
(157.52 ... 196.85 inch)
Extended rod, 5 001 ... 5 500 mm ¢ S Manufacturer's test certificate: M to DIN 55350, ¢ C11
(196.89 ... 216.53 inch) Part 18 and ISO 9000
Thermal isolator Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Without thermal isolator ¢ 0 Operating Instructions
With thermal isolator [for process connection ¢ 1
temperatures over 85 °C (185 °F)] Note: The Operating Instructions should be See page 4/36
ordered as a separate line on the order.
Remote mount electronics and This device is shipped with the Siemens Milltronics
mounting bracket manual DVD containing the ATEX Quick Start and
With 2 m (79 inch) of cable ¢ 2 manual library.
With 5 m (197 inch) of cable ¢ 3
Accessories See page 4/36
Wetted seals
FKM and PTFE ¢ 0 ¢ We can offer shorter delivery times for configurations designated with the
FFKM and PTFE [for process temperatures above ¢ 1 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body ¢ 0
316L stainless steel with PVDF probe body ¢ 1
Approvals
Non-Sparking: ¢ B
CE, RCM, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: ¢ C
CE, RCM, ATEX II 1/2 D T100 °C
1)
Intrinsically Safe: ¢ D
CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C

4/34 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS200 - Digital - PFA Rod with 7ML5644- Pointek CLS200 - Digital - PFA Rod with 7ML5644-
PFA Flanged process connection 77 7 77 - 77 7 0 PFA Flanged process connection 7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level Versatile inverse frequency shift capacitance level
and material detection switch with optional process and material detection switch with optional process
connection choices and configurable output. connection choices and configurable output.
CLS200 is ideal for detection of liquids, solids, CLS200 is ideal for detection of liquids, solids,
slurries, foam, and interfaces, and has the ability to slurries, foam, and interfaces, and has the ability to
tune out build-up on the probe. tune out build-up on the probe.
Click on the Article No. for the online configura- Remote mount electronics and
tion in the PIA Life Cycle Portal. mounting bracket
Process connection With 2 m (79 inch) of cable 2
Welded flange, PFA coated, 316L stainless steel, With 5 m (197 inch) of cable 3
raised face Wetted seals
1" ASME, 150 lb 5A FKM 0
1" ASME, 300 lb 5B FFKM [for process temperatures above 1
1" ASME, 600 lb 5C -20 °C (-4 °F)]
1½" ASME, 150 lb 5D Probe material

4
1½" ASME, 300 lb 5E PFA Coated 316L stainless steel with PPS probe 0
1½" ASME, 600 lb 5F body
PFA Coated 316L stainless steel with PVDF probe 1
2" ASME, 150 lb 5G body
2" ASME, 300 lb 5H
2" ASME, 600 lb 5J Approvals
3" ASME, 150 lb 5K Non-incendive: F
3" ASME, 300 lb 5L CSA/FM Class I, Div. 2, Groups A, B, C, D
3" ASME, 600 lb 5M CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
4" ASME, 150 lb 5N
4" ASME, 300 lb 5P Dust Ignition Proof with IS Probe: G
4" ASME, 600 lb 5Q CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Welded flange, PFA coated, 316L stainless steel,
Type A flat faced Intrinsically Safe:1) H
DN 25, PN 16 6A CSA/FM Class I, Div. 1, Groups A, B, C, D
DN 25, PN 40 6B CSA/FM Class II, Div. 1, Groups E, F, G
DN 40, PN 16 6C CSA/FM Class III T4
DN 40, PN 40 6D Explosion Proof with IS Probe: J
DN 50, PN 16 6E CSA/FM Class I, Div. 1, Groups A, B, C, D
DN 50, PN 40 6F CSA/FM Class II, Div. 1, Groups E, F, G
DN 80, PN 16 6G CSA/FM Class III T4
DN 80, PN 40 6H General Purpose (CSA, FM) K
DN 100, PN 16 6J Enclosure and lid
DN 100, PN 40 6K Aluminum epoxy coated
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable 2 x ½" NPT via adapter - cable inlet, IP65 A
ASME B16.5 or EN 1092-1 standard.) 2 x M20x1.5 cable inlet, IP65 B
2 x ½" NPT via adapter - cable inlet, IP68 C
Probe length (length from process connection 2 x M20x1.5 cable inlet, IP68 D
face)
1)
Note: No Y01 needed in Order code for Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
standard lengths
Compact 98 mm (3.86 inch) A
Extended rod, 250 mm (9.84 inch) B Selection and Ordering data Order code
Extended rod, 350 mm (13.78 inch) C
Further designs
Extended rod, 500 mm (19.69 inch) D
Extended rod, 750 mm (29.53 inch) E Please add "-Z" to Article No. and specify Order
Extended rod, 1 000 mm (39.37 inch) F code(s).
Extended rod, 1 250 mm (49.21 inch) G Total insertion length: enter the total insertion length Y01
Extended rod, 1 350 mm (53.15 inch) H
Extended rod, 1 500 mm (59.06 inch) J in plain text description
Extended rod, 1 750 mm (68.90 inch) K Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Extended rod, 2 000 mm (78.74 inch) L Measuring-point number/identification
Add Order code Y01 and plain text: (max. 27 characters) specify in plain text
"Insertion length ... mm" Manufacturer's test certificate: M to DIN 55350, C11
Extended rod, 200 ... 1 000 mm (7.87 ... 39.37 inch) M Part 18 and ISO 9000
Extended rod, 1 001 ... 2 000 mm N
Inspection Certificate Type 3.1 per EN 10204 C12
(39.41 ... 78.74 inch)
Extended rod, 2 001 ... 3 000 mm P Operating Instructions
(78.78 ... 118.11 inch) Note: The Operating Instructions should be See page 4/36
Extended rod, 3 001 ... 4 000 mm Q ordered as a separate line on the order.
(118.15 ... 157.48 inch) This device is shipped with the Siemens Milltronics
Extended rod, 4 001 ... 5 000 mm R manual DVD containing the ATEX Quick Start and
(157.52 ... 196.85 inch) manual library.
Extended rod, 5 001 ... 5 500 mm S
(196.89 ... 216.53 inch) Accessories See page 4/36
Thermal isolator
Without thermal isolator 0
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]

Siemens FI 01 · 2015 4/35


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital
Selection and Ordering data Article No. ■ Options
Operating Instructions - Standard
English 7ML1998-5JH04 Optional SensGuard
German 7ML1998-5JH34 Internal thread ¾" NPT
Note: The Operating Instructions should be
ordered as a separate line on the order.

(1.26)

(1.26)
32

32
Quick Start manual, multi-language A5E32221251 Process
Process connection
This device is shipped with the Siemens Milltronics connection R 1" (BSPT)
manual DVD containing the ATEX Quick Start and ¾" NPT
Operating Instructions library.

91 (3.6)
Operating Instructions - Digital

91 (3.6)
70 (2.75)

70 (2.75)
English 7ML1998-5JJ05
German 7ML1998-5JJ34
French 7ML1998-5JJ11

4
Note: The Operating Instructions should be
ordered as a separate line on the order. Optional SensGuard, dimensions in mm (inch)
Quick Start manual, multi-language A5E32221496
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
SensGuard, ¾" NPT (PPS) 7ML1830-1DL
Only available for CLS200 with ¾" NPT thread
SensGuard, R 1" (BSPT) (PPS) 7ML1830-1DM
Only available for CLS200 with ¾" NPT thread
One metallic cable gland M20x1.5, -40 ... +80 °C 7ML1930-1AQ
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA
NEMA6, -40 ... -100 °C (-40 ... -212 °F),
cable size 6 ... 12 mm (0.236 ... 0.472 inch)
M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC
NEMA6,-40 ... -100 °C (-40 ... -212 °F),
cable size 7 ... 12 mm (0.275 ... 0.472 inch)
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition 7ML1830-1JB
Proof, Flameproof Exd, and Increased Safety ATEX
II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21,
Zone 22, and in Gas Groups IIA,IIB and IIC)
-60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD
Flameproof Exd, and Increased Safety ATEX II 2
GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22
and in Gas Groups IIA, IIB and IIC)
-60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
Blind threaded flanges are available.
Please contact ceg.smpi@siemens.com with a
completed application data sheet on page 4/11
Pointek Specials See page 4/80

4/36 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

■ Characteristic curves
Pressure/temperature curve
CLS200 sliding coupling
threaded process connections
(7ML5633 and 7ML5643)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)

4
Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5633 and 7ML5643)

Pressure/temperature curve
CLS200 cable
Threaded process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)

Siemens FI 01 · 2015 4/37


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

Pressure/temperature curve
CLS200 compact and extended rod
Threaded process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

4 Atmospheric 10 bar (145 psi)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 or 7ML5640)

Pressure/temperature curve
CLS200 compact and extended sanitary type
Sanitary process connections
(7ML5632 and 7ML5642)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5632 and 7ML5642)

4/38 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

Pressure/temperature curve
CLS200 cable
ASME flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
4
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)

Pressure/temperature curve
CLS200 compact and extended rod
ASME flanged process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)

Siemens FI 01 · 2015 4/39


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

Pressure/temperature curve
CLS200 cable
EN flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


PN 161)
Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)

4 -1 bar (-14.5 psi)


-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)

Pressure/Temperature Curve
CLS200 Compact and Extended Rod
EN Flanged Process Connections
(7ML5630 and 7ML5640)

Permitted Operating Pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

Atmospheric 10 bar (145 psi) PN 161)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted Operating Temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)

4/40 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

■ Dimensional drawings
Compact version Extended rod version Extended cable version
Threaded Threaded Threaded
(7ML5630 and 7ML5640) (7ML5630 and 7ML5640) (7ML5631 and 7ML5641)

Electronics/
enclosure

Y01 (insertion length)


(4.7)
120

22
(0.87)

PPS or optional 316L stainless


PVDF probe steel extension

Y01 (insertion length)


Ø20 (0.79) FEP insulated
cable Ø6 (0.3)
4
(3.3)
84
PPS or optional
Sanitary compact version
PVDF probe
Sanitary fitting 316L stainless steel
(7ML5632 and 7ML5642) sensor weight
Min. insertion length = 200 (7.87)
Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
84
316L stainless steel PPS or optional
sanitary process PVDF probe
connection
Min. insertion length = 500 (19.69)
(3.8)
98

Max. insertion length = 30 000 (1 181)


PPS or optional
Applicable for liquids and solids
PVDF probe
applications. Cable can be shortened
on site.

Sanitary extended version Sliding coupling version


Sanitary fitting Threaded
2 cable entries
(7ML5632 and 7ML5642) (7ML5633 and 7ML5643)
½" NPT or
M20 x 1.5
M20: 135 (5.32)
½" NPT: 150 (5.91)

316L stainless steel


sanitary process
Lid with window
connection
Y01 (insertion length)

316L stainless
316L stainless steel sliding
steel extension coupling
Y01 (insertion length)

Ø24 (0.95)
164 (6.46)

Lid without window


(3.8)
252 (9.92)

98

PPS or optional
PVDF probe
Min. 215
(5.94)

(8.46)
151

239 (9.41)

Min. insertion length = 110 (4.3) Ø20 (0.79)


Max. insertion length = 5 500 (216)
(3.3)
84

Thermal PPS or optional


isolator PVDF probe

Min. insertion length = 350 (13.82)


Max. insertion length = 5 500 (216)

Pointek CLS200 - Threaded/sanitary process connections, dimensions in mm (inch)

Siemens FI 01 · 2015 4/41


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

Compact version Extended rod version Extended cable version


Welded Flange (7ML5630 and 7ML5640) Welded Flange (7ML5630 and 7ML5640) Welded Flange
Welded Flange, PFA coated Welded Flange, PFA coated (7ML5631 and 7ML5641)
(7ML5634 and 7ML5644) (7ML5634 and 7ML5644)

Electronics/
enclosure

Y01 (insertion length)


(3.8)

316L stainless
98

PPS or optional steel extension


PVDF probe (or PFA coated

Y01 (insertion length)


Ø20 (0.79) FEP insulated
cable Ø6 (0.3)

(3.3)
84
2 cable entries

4
PPS or optional
½" NPT or PVDF probe
M20 x 1.5 316L stainless steel
sensor weight
M20: 135 (5.32) Min. insertion length = 200 (7.87)
½" NPT: 150 (5.91) Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
lid with window

84
PPS or optional
PVDF probe

Min. insertion length = 500 (19.69)


Max. insertion length = 30 000 (1 181)
Applicable for liquids and solids applica-
164 (6.46)

Lid without window


tions. Cable can be shortened on site.
252 (9.92)

Flange Facing (raised face)


(5.94)
151

239 (9.41)

Flange Class Facing thickness


ASME 150/300 2 (0.08)
Thermal ASME 600/900 7 (0.28)
isolator
PN16/40 2 (0.08)

Insertion length does not include any raised face/gasket face dimension
(see Flange Facing Table above)

Pointek CLS200 - Flanged Process Connections, dimensions in mm (inch)

4/42 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS200 – Standard and Digital

■ Schematics
Wiring: Pointek CLS200 standard
White
Black
Red P2
Trip
point
(+)

(f )

Switch bank
P1 S1 K1
OFF
GND

- + 3 2 1 K4
Delay Sensor
L1 L3
Sensor Power 1 2 3
L2 status on
Output Power
status supply

4
12 to 250 V AC/DC

NC NO NO
K2 K3
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.

Wiring: Pointek CLS200 Digital

White
Reed
Test input contact*
White

Red (+)

Sensor Black (-)


Alarm output
solid-state switch Orange (f)

24 V DC/PROFIBUS PA

Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.

*Magnet activated sensor Test


A magnet can be used to test the sensor without opening the lid of the
Pointek CLS200 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.

Pointek CLS200 connections

Siemens FI 01 · 2015 4/43


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS300 (standard version) is an inverse frequency shift falling material.
capacitance level and material detection switch with optional
rod/cable choices and configurable output. CLS300 is ideal for
detecting liquids, solids, slurries, foam, and interfaces in
demanding conditions where high pressure and temperatures
are present and has the ability to tune out build-up on the probe.

■ Benefits
• Active-Shield technology so measurement is unaffected by
material buildup or nozzle interference in active shield section
• Performs in extremely abrasive conditions because of solid
rod construction Build up of material in active shield area does not affect
switch operation.
• Three LED indicators for adjustment control, output status and
power
• High-temperature version up to 400 °C (752 °F)

■ Application
Pointek CLS300 standard version has three LED indicators with
basic relay and solid-state switch alarms.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry. M
in
The fully potted electronics are unaffected by condensation, .5
0
dust or vibration. (2
)
Wetted parts are made of stainless steel with a PFA shield for
high chemical resistance, and of ceramic and stainless steel for
high temperature version. Materials with low or high dielectric
constants can be accurately detected. The unique Active Shield Min.
suppresses interference from material buildup or long installa- 50 (2)
tion nozzles.
The unique modular design of the Pointek CLS300 provides a Install probe at least 50 (2) from tank wall.
wide range of configurations, process connections, extensions Note angle of repose and adjust accordingly.
and approvals to meet the temperature and pressure require-
ments of specific applications. The modular design makes
Pointek CLS300 installation, dimensions in mm (inch)
ordering easier and reduces stocking requirements. A wide
range of probe configurations are available, including rod and
cable versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and
mining applications

4/44 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard

■ Technical specifications
Mode of operation Design
Measuring principle Inverse frequency shift capacitive Material (enclosure) Powder-coated aluminum with gasket
level detection
Degree of Protection Standard: Type 4/NEMA 4/IP65
Input Optional: Type 4/NEMA 4/IP68
Measured variable Change in picoFarad (pF) Cable inlet 2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
Output including 1 plugged entry)
Output signal Controls and displays
• Relay output 1 SPDT Form C relay
- Max. contact voltage • 30 V DC Displays 3 LEDs, for probe status,
• 250 V AC output status and power supply
- Max. contact current • 5 A (DC) Potentiometers 2 potentiometers for time delay and
• 8 A (AC) sensitivity
- Max. switching capacity • 150 W (DC) Switches 5 DIP switches for delay on/off,
• 2 000 VA (AC) fail-safe high/low, time delay
- Time delay (ON and/or OFF) 1 ... 60 s test/adjust, high/low sensitivity,
• Solid-state output
- Output Galvanically isolated Power supply
test delay settings
4
- Protection Against reversed polarity (bipolar)
Supply 12 ... 250 V AC/DC, 0 ... 60 Hz,
- Max. switching voltage • 30 V (DC)
galvanically isolated, 2 W
• 30 V peak (AC)
- Max. load current 82 mA Certificates and approvals
- Voltage drop < 1 V, typical at 50 mA General Purpose CSA, FM, CE, RCM
- Time delay (pre or post switching) 1 ... 60 s
Flameproof Enclosure with IS Probe ATEX II 1/2 G EEx d[ia] IIC T6...T1
Accuracy ATEX II 1/2 D T100 °C
Resolution Dust Ignition Proof with IS Probe ATEX II 1/2 D T100 °C
• Min. sensitivity (pF) 1 % change in actual capacitance CSA/FM Class II, Div. 1,
• Max. temperature error 0.2 % of actual capacitance value Groups E, F, G
CSA/FM Class III T4
Rated operating conditions1)
Explosion Proof Enclosure with CSA/FM Class I, Div. 1,
Installation conditions IS Probe Groups A, B, C, D
• Location Indoor/outdoor CSA/FM Class II, Div. 1,
Groups E, F, G
Ambient conditions CSA/FM Class III T4
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2)
Marine Lloyds Register of Shipping,
Medium conditions Liquids, bulk solids, slurries and Categories ENV1, ENV2 and ENV5
interfaces, and applications with
viscous materials Overfill Protection WHG (Germany)
VLAREM II (Belgium)
• Relative dielectric constant r Min. 1.5
Others Pattern Approval (China)
• Process temperature 1)
When operation is in areas classified as hazardous, observe restrictions
- Rod/Cable version -40 ... +200 °C (-40 ... +392 °F)2) according to relevant certificate.
- High-temperature version -40 ... +400 °C (-40 ... +752 °F) See also Pressure/Temperature curves starting on page 4/58.
2)
• Process pressure3) -1 ... +35 bar g Thermal isolator is used if process connection temperature exceeds 85 °C
(-14.6 ... +511 psi g) (185 °F).
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 4/58.

Design: Probe
Rod version High Temperature version Cable version
Length Min. 250 mm (9.8 inch), Min. 250 mm (9.8 inch), Min. 1 000 mm (40 inch),
max. 1 000 mm (40 inch) max. 1 000 mm (40 inch) max. 25 000 mm (984 inch)
Sensor wetted parts PFA (no insulation on active probe), Ceramic (ZrO21)) isolators 316 stainless steel, optional PFA,
316L stainless steel, PEEK isolators (no insulation on active probe), PEEK isolators
316L stainless steel
O-ring seal material FKM (optional FFKM)2) Graphite2) FKM (optional FFKM)2)
Thermal isolator Optional Standard Optional
Extension User selectable length User selectable length User selectable cable length
1) Zirconium Oxide
2)
For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-Rings.

Siemens FI 01 · 2015 4/45


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS300 - Standard - Rod Version 7ML5650- Pointek CLS300 - Standard - Rod Version 7ML5650-
with Threaded or Flanged process connection 77777 - 7777
with Threaded or Flanged process connection 77777 - 7777
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
material detection switch with optional rod/cable material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high interfaces in demanding conditions where high
pressure and temperatures are present, and has pressure and temperatures are present, and has
the ability to tune out build-up on the probe. the ability to tune out build-up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, factory adjusted length ¢ E
Threaded, 316L stainless steel 250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length ¢ F
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A 500 ... 749 mm (19.69 ... 29.49 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B Extended rod, factory adjusted length ¢ G
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C 750 ... 999 mm (29.53 ... 39.3 inch)

4 1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D Thermal isolator


R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A Without thermal isolator ¢ 0
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B With thermal isolator [for process connection ¢ 1
R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D temperatures over 85 °C (185 °F)]
JIS B 0203] Wetted seals
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3A FKM ¢ 0
JIS B 0202] FFKM [for process temperatures above ¢ 1
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B -20 °C (-4 °F)]
JIS B 0202] Probe material
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D 316L stainless steel with PFA lining and PEEK ¢ 0
JIS B 0202] isolators
Welded flange, 316L stainless steel, raised face Approvals
1" ASME, 150 lb ¢ 5A Dust Ignition Proof with IS Probe: ¢ C
1" ASME, 300 lb 5B CE, RCM, ATEX II 1/2 D T100 °C
1" ASME, 600 lb 5C
Flameproof Enclosure with IS Probe: ¢ D
1½" ASME, 150 lb ¢ 5D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
1½" ASME, 300 lb 5E ATEX II 1/2 D T100 °C
1½" ASME, 600 lb 5F Flameproof Enclosure with IS Probe, ¢ E
with WHG approval:
2" ASME, 150 lb ¢ 5G CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
2" ASME, 300 lb 5H ATEX II 1/2 D T100 °C
2" ASME, 600 lb 5J
Dust Ignition Proof with IS Probe: ¢ F
3" ASME, 150 lb ¢ 5K CSA/FM Class II, Div. 1, Groups E, F, G
3" ASME, 300 lb 5L CSA/FM Class III T4
3" ASME, 600 lb 5M Explosion Proof Enclosure with IS Probe: ¢ G
4" ASME, 150 lb ¢ 5N CSA/FM Class I, Div. 1, Groups A, B, C, D
4" ASME, 300 lb 5P CSA/FM Class II, Div. 1, Groups E, F, G
4" ASME, 600 lb 5Q CSA/FM Class III T4

Welded flange, 316L stainless steel, General Purpose (CSA, FM) ¢ H


Type A flat faced General Purpose (CE, RCM) ¢ J
DN 25, PN 16 ¢ 6A
General Purpose with WHG approval ¢ K
DN 25, PN 40 6B (CSA, FM, CE, RCM)
DN 40, PN 16 ¢ 6C
Enclosure and lid
DN 40, PN 40 6D Aluminum epoxy coated
DN 50, PN 16 ¢ 6E 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
DN 50, PN 40 6F 2 x M20x1.5 cable inlet, IP65 ¢ B
DN 80, PN 16 ¢ 6G 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
DN 80, PN 40 6H 2 x M20x1.5 cable inlet, IP68 ¢ D
DN 100, PN 16 ¢ 6J Active shield length
DN 100, PN 40 6K Standard length - ¢ 0
(Note: Flange bolting patterns and facings (125 mm threaded, 105 mm flanged)
dimensionally correspond to the applicable Extended shield - ¢ 1
ASME B16.5 or EN 1092-1 standard.) (250 mm threaded, 230 mm flanged)1)
Probe length (length from flange face) Extended shield - ¢ 2
(threaded lengths include process thread) (400 mm threaded, 380 mm flanged)2)
Note: No Y01 needed in Order code for 1) Available with Probe version options B ... D, F, G only
standard lengths [ 500 mm (19.69 inch)]
2)
Standard version, rod 350 mm (13.78 inch) ¢ A Available with Probe version options C, D, and, G only
Extended rod, length 500 mm (19.69 inch) ¢ B [ 750 mm (29.53 inch)]
Extended rod, length 750 mm (29.53 inch) ¢ C
¢ We can offer shorter delivery times for configurations designated with the
Extended rod, length 1 000 mm (39.37 inch) ¢ D Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/46 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Pointek CLS300 - Standard - Cable Version 7ML5651-
with Threaded or Flanged process connection 7 7 7 77 - 77 7 7
Please add "-Z" to Article No. and specify Order
code(s). Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
Total insertion length: enter the total insertion length ¢ Y01 choices and configurable output. CLS300 is ideal
in plain text description for detecting liquids, solids, slurries, foam, and
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15 interfaces in demanding conditions where high
Measuring-point number/identification pressure and temperatures are present, and has
(max. 27 characters) specify in plain text the ability to tune out build-up on the probe.

Manufacturer's test certificate: M to DIN 55350, ¢ C11 Click on the Article No. for the online configura-
Part 18 and to ISO 9000 tion in the PIA Life Cycle Portal.
Process connection
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Threaded, 316L stainless steel
Operating Instructions 1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C
Note: The Operating Instructions should be See page 4/57 1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D
ordered as a separate line on the order. R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D
This device is shipped with the Siemens Milltronics JIS B 0203]
manual DVD containing the ATEX Quick Start and
manual library.
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
¢ 3D
4
Accessories See page 4/57 Welded flange, 316L stainless steel, raised face
¢ We can offer shorter delivery times for configurations designated with the 1½" ASME, 150 lb ¢ 5D
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. 1½" ASME, 300 lb 5E
1½" ASME, 600 lb 5F
2" ASME, 150 lb ¢ 5G
2" ASME, 300 lb 5H
2" ASME, 600 lb 5J
3" ASME, 150 lb ¢ 5K
3" ASME, 300 lb 5L
3" ASME, 600 lb 5M
4" ASME, 150 lb ¢ 5N
4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 40, PN 16 ¢ 6C
DN 40, PN 40 6D
DN 50, PN 16 ¢ 6E
DN 50, PN 40 6F
DN 80, PN 16 ¢ 6G
DN 80, PN 40 6H
DN 100, PN 16 ¢ 6J
DN 100, PN 40 6K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Extended cable, 3 000 mm (118.11 inch), ¢ A
length can be shortened by customer
Extended cable, 6 000 mm (236.22 inch), ¢ B
length can be shortened by customer
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 1 000 mm ¢ E
(19.69 ... 39.37 inch)
Extended cable, 1 001 ... 5 000 mm ¢ F
(39.41 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm ¢ G
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm ¢ H
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm ¢ J
(590.59 ... 787.40 inch)
Extended cable, 20 001 ... 25 000 mm ¢ K
(787.44 ... 984.25 inch)

Siemens FI 01 · 2015 4/47


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard

Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS300 - Standard - Cable Version 7ML5651- Further designs
with Threaded or Flanged process connection 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order
Inverse frequency shift capacitance level and code(s).
material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal Total insertion length: enter the total insertion length ¢ Y01
for detecting liquids, solids, slurries, foam, and in plain text description
interfaces in demanding conditions where high
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
pressure and temperatures are present, and has Measuring-point number/identification
the ability to tune out build-up on the probe.
(max. 27 characters) specify in plain text
Thermal isolator
Manufacturer's test certificate: M to DIN 55350, ¢ C11
Without thermal isolator ¢ 0 Part 18 and to ISO 9000
With thermal isolator [for process connection ¢ 1
temperatures over 85 °C (185 °F)] Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Wetted seals Operating Instructions
FKM ¢ 0 Note: The Operating Instructions should be See page 4/57
FFKM [for process temperatures above ¢ 1 ordered as a separate line on the order.
-20 °C (-4 °F)] This device is shipped with the Siemens Milltronics
4 Probe material
Bare 316L stainless steel cable, PEEK isolators and ¢ 0
manual DVD containing the ATEX Quick Start and
manual library.
316L stainless steel cable weight Accessories See page 4/57
PFA coated cable, PEEK isolators and 316L ¢ 1
stainless steel cable weight ¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Approvals
Dust Ignition Proof with IS Probe: ¢ C
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, ¢ E
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe: ¢ F
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe: ¢ G
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM) ¢ H
General Purpose (CE, RCM) ¢ J
General Purpose with WHG approval ¢ K
(CSA, FM, CE, RCM)
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
2 x M20x1.5 cable inlet, IP65 ¢ B
2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
2 x M20x1.5 cable inlet, IP68 ¢ D
Active shield length
Standard length - ¢ 0
(125 mm threaded, 105 mm flanged)
Extended shield - ¢ 1
(250 mm threaded, 230 mm flanged)1)
Extended shield - ¢ 2
(400 mm threaded, 380 mm flanged)1)
1) Available with Probe version options A, B, F ... K, only
[ 1 000 mm (39.7 inch)]

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/48 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS300 - Standard - High Temperature 7ML5652- Pointek CLS300 - Standard - High Temperature 7ML5652-
Rod Version with Threaded or Flanged process 7 7 7 00 7 - 7 7 7 7
Rod Version with Threaded or Flanged process 7 7 7 00 7 - 7 7 7 7
connection connection
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
material detection switch with optional rod/cable material detection switch with optional rod/cable
choices and configurable output. CLS300 is ideal choices and configurable output. CLS300 is ideal
for detecting liquids, solids, slurries, foam, and for detecting liquids, solids, slurries, foam, and
interfaces in demanding conditions where high interfaces in demanding conditions where high
pressure and temperatures are present, and has pressure and temperatures are present, and has
the ability to tune out build-up on the probe. the ability to tune out build-up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, factory adjusted length ¢ E
Threaded, 316L stainless steel 250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length ¢ F
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A 500 ... 749 mm (19.69 ... 29.49 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B Extended rod, factory adjusted length ¢ G
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C 750 ... 999 mm (29.53 ... 39.3 inch)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
Wetted seals 4
Graphite ¢ 0
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B
Probe material
R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D 316L stainless steel with ceramic (ZrO2) isolators ¢ 0
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3A Approvals
JIS B 0202] Dust Ignition Proof with IS Probe: ¢ C
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B CE, RCM, ATEX II 1/2 D T100 °C
JIS B 0202]
Flameproof Enclosure with IS Probe: ¢ D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
JIS B 0202] ATEXII 1/2 D T100 °C
Welded flange, 316L stainless steel, raised face Flameproof Enclosure with IS Probe, ¢ E
with WHG approval:
1" ASME, 150 lb ¢ 5A CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
1" ASME, 300 lb 5B ATEX II 1/2 D T100 °C
1" ASME, 600 lb 5C
Dust Ignition Proof with IS Probe: ¢ F
1½" ASME, 150 lb ¢ 5D CSA/FM Class II, Div. 1, Groups E, F, G
1½" ASME, 300 lb 5E CSA/FM Class III T4
1½" ASME, 600 lb 5F Explosion Proof Enclosure with IS Probe: ¢ G
2" ASME, 150 lb ¢ 5G CSA/FM Class I, Div. 1, Groups A, B, C, D
2" ASME, 300 lb 5H CSA/FM Class II, Div. 1, Groups E, F, G
2" ASME, 600 lb 5J CSA/FM Class III T4
3" ASME, 150 lb ¢ 5K General Purpose (CSA, FM) ¢ H
3" ASME, 300 lb 5L General Purpose (CE, RCM) ¢ J
3" ASME, 600 lb 5M General Purpose with WHG approval ¢ K
4" ASME, 150 lb ¢ 5N (CSA, FM, CE, RCM)
4" ASME, 300 lb 5P Enclosure and lid
4" ASME, 600 lb 5Q Aluminum epoxy coated
Welded flange, 316L stainless steel, 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
Type A flat faced 2 x M20x1.5 cable inlet, IP65 ¢ B
DN 25, PN 16 ¢ 6A 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
DN 25, PN 40 6B 2 x M20x1.5 cable inlet, IP68 ¢ D
DN 40, PN 16 ¢ 6C
Active shield length
DN 40, PN 40 6D Standard length - ¢ 0
DN 50, PN 16 ¢ 6E (125 mm threaded, 105 mm flanged)
DN 50, PN 40 6F Extended shield - ¢ 1
DN 80, PN 16 ¢ 6G (250 mm threaded, 230 mm flanged)1)
DN 80, PN 40 6H Extended shield - ¢ 2
DN 100, PN 16 ¢ 6J (400 mm threaded, 380 mm flanged)2)
1)
DN 100, PN 40 6K Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
(Note: Flange bolting patterns and facings 2)
dimensionally correspond to the applicable Available with Probe version options C, D, and, G only
ASME B16.5 or EN 1092-1 standard.) [ 750 mm (29.53 inch)]

Probe length (length from flange face) ¢ We can offer shorter delivery times for configurations designated with the
(threaded lengths include process thread) Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Note: No Y01 needed in Order code for
standard lengths
Standard version rod 350 mm (13.78 inch) ¢ A
Extended rod, length 500 mm (19.69 inch) ¢ B
Extended rod, length 750 mm (29.53 inch) ¢ C
Extended rod, length 1 000 mm (39.37 inch) ¢ D

Siemens FI 01 · 2015 4/49


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length ¢ Y01
in plain text description
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350, ¢ C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Operating Instructions
Note: The Operating Instructions should be See page 4/57
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
4 manual DVD containing the ATEX Quick Start and
manual library.
Accessories See page 4/57
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/50 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital
The unique modular design of the Pointek CLS300 provides a
■ Overview wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure require-
ments of specific applications. The modular design makes
ordering easier and reduces stocking requirements. A wide
range of probe configurations are available, including rod and
cable versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and
mining applications

■ Configuration
Installation

4
Pointek CLS300 (digital version) is an inverse frequency shift
capacitance level and material detection switch with optional
rod/cable choices and configurable output. It is ideal for detect-
ing liquids, solids, slurries, foam and interfaces in demanding
conditions where high pressure and temperatures are present
and has the ability to tune out build-up on the probe. The digital
version includes PROFIBUS PA, an LCD display, and advanced
diagnostic features.

■ Benefits
• Active-Shield technology so measurement is unaffected by Keep unit out of path of falling material, or protect probe from
material buildup or nozzle interference in active shield section falling material.

• Performs in extremely abrasive conditions because of solid


rod construction
• Push-button calibration, full-function diagnostics
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)

■ Application Build up of material in active shield area does not affect


switch operation.
Pointek CLS300 digital version provides an integral LCD display
for stand-alone use, with PROFIBUS PA communication
(Profile version 3.0, Class B) when required. Solid-state switch
alarm is standard.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
The fully potted electronics are unaffected by condensation,
dust or vibration.
M

Wetted parts are made of stainless steel with a PFA shield for
in
.5

high chemical resistance, and of ceramic and stainless steel for


0
(2

high temperature version. Materials with low or high dielectric


)

constants can be accurately detected. The unique Active Shield


suppresses interference from material buildup or long installa-
tion nozzles.
Min.
50 (2)

Install probe at least 50 (2) from tank wall.


Note angle of repose and adjust accordingly.

Pointek CLS300 installation, dimensions in mm (inch)

Siemens FI 01 · 2015 4/51


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital

■ Technical specifications
Mode of operation Controls and displays
Measuring principle Inverse frequency shift capacitive Local display LCD
level detection Configuration • Locally, using 3 button keypad
(for standalone operation)
Input • Remotely, using SIMATIC PDM
Measured variable Change in picoFarad (pF) (for installation on a network)

Output Power supply


Bus voltage (at process connection) • Standard: 12 ... 30 V DC
Solid-state output • Intrinsically Safe: 12 ... 24 V DC
• Output Galvanically isolated Current consumption 12.5 mA
• Protection Against reversed polarity (bipolar)
Certificates and approvals
• Max. switching voltage • 30 V (DC)
• 30 V peak (AC) General Purpose CSA, FM, CE, RCM
• Max. load current 82 mA Dust Ignition Proof ATEX II 1/2 D, 2 D IP6X T100 °C
• Voltage drop < 1 V, typical at 50 mA Flameproof Enclosure With IS Probe ATEX II 1/2 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
• Time delay (pre or post switching) Programmable by user (0 ... 100 s)
Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1,
Fail-safe mode Min. or max.
4
Groups E, F, G
Connection Removable terminal block CSA/FM Class III T4
Accuracy Intrinsically Safe4) ATEX II 1 G EEx ia IIC T6...T4
ATEX II 1/2 D, 2 D IP6X T100 °C
Resolution
CSA/FM Class I, Div. 1,
• Min. sensitivity (pF) 1 % change in actual capacitance Groups A, B, C, D
• Max. temperature error 0.2 % of actual capacitance value CSA/FM Class II, Div. 1,
Groups E, F, G
Rated operating conditions1)
CSA/FM Class III T4
Installation conditions Non-incendive CSA/FM Class I, Div. 2,
Groups A, B, C, D
Location Indoor/outdoor CSA/FM Class II, Div. 2,
Ambient conditions Groups F, G
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) CSA/FM Class III T4 or T6
Explosion Proof with IS Probe CSA/FM Class I, Div. 1,
Medium conditions Liquids, bulk solids, slurries and Groups A, B, C, D
interfaces, and applications with CSA/FM Class II, Div. 1,
viscous materials Groups E, F, G
• Relative dielectric constant r Min. 1.5 CSA/FM Class III T4
• Process temperature Marine Lloyds Register of Shipping,
- Rod/Cable version -40 ... +200 °C (-40 ... +392 °F)2) Categories ENV1, ENV2 and ENV5
- High Temperature version -40 ... +400 °C (-40 ... +752 °F) Others Pattern Approval (China)
• Process pressure3) -1 ... +35 bar g (-14.6 ... +511 psi g) Communication PROFIBUS PA
Design (IEC 61158 CPF3 CP3/2)
Material (enclosure) Powder-coated aluminum with gasket Bus physical layer:
IEC 61158-2 MBP-(IS)
Degree of protection Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68 Device profile: PROFIBUS PA profile
Cable inlet 2 x M20x1.5 thread for Process Control Devices Version
(option: 2 x ½" NPT conduit entry 3.0, Class B
including 1 plugged entry) FISCO field device
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves starting on page 4/58.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 4/58.
4)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection

Design: Probe
Rod version High Temperature version Cable version
Length Min. 250 mm (9.8 inch), Min. 250 mm (9.8 inch), Min. 1 000 mm (40 inch),
max. 1 000 mm (40 inch) max. 1 000 mm (40 inch) max. 25 000 mm (984 inch)
Sensor wetted parts PFA (no insulation on active probe), Ceramic (ZrO21)) isolators 316 stainless steel, optional PFA,
316L stainless steel, PEEK isolators (no insulation on active probe), PEEK isolators
316L stainless steel
O-ring seal material FKM (optional FFKM)2) Graphite2) FKM (optional FFKM)2)
Thermal isolator Optional Standard Optional
Extension User selectable length User selectable length User selectable cable length
1)
Zirconium Oxide
2)
For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-Rings

4/52 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS300 - Digital - Rod with 7ML5660- Pointek CLS300 - Digital - Rod with 7ML5660-
Threaded or Flanged process connection 77 7 77 - 77 77
Threaded or Flanged process connection 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
material detection switch with optional rod/cable material detection switch with optional rod/cable
choices and configurable output. It is ideal for choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and inter- detecting liquids, solids, slurries, foam, and inter-
faces in demanding conditions where high pres- faces in demanding conditions where high pres-
sure and temperatures are present and has the sure and temperatures are present and has the
ability to tune out build-up on the probe. ability to tune out build-up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, factory adjusted length ¢ E
Threaded, 316L stainless steel 250 ... 499 mm (9.8 ... 19.65 inch)
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A Extended rod, factory adjusted length ¢ F
500 ... 749 mm (19.69 ... 29.49 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B
Extended rod, factory adjusted length ¢ G
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C
750 ... 999 mm (29.53 ... 39.3 inch)

4
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D
Thermal isolator
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1A
Without thermal isolator ¢ 0
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B
With thermal isolator [for process connection ¢ 1
R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D temperatures over 85 °C (185 °F)]
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3A Wetted seals
JIS B 0202] FKM ¢ 0
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B FFKM [for process temperatures above -20 °C (-4 °F)]¢ 1
JIS B 0202] Probe material
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D 316L stainless steel with PFA lining and PEEK ¢ 0
JIS B 0202] isolators
Welded flange, 316L stainless steel, raised face Approvals
1" ASME, 150 lb ¢ 5A Dust Ignition Proof: ¢ B
1" ASME, 300 lb 5B CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
1" ASME, 600 lb 5C Intrinsically Safe1) ¢ C
1½" ASME, 150 lb ¢ 5D CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
1½" ASME, 300 lb 5E ATEX II 1/2 D, 2 D IP6X T100 °C
1½" ASME, 600 lb 5F Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
2" ASME, 150 lb ¢ 5G
ATEX II 1/2 D T100 °C
2" ASME, 300 lb 5H
Dust Ignition Proof with IS Probe: ¢ E
2" ASME, 600 lb 5J CSA/FM Class II, Div. 1, Groups E, F, G
3" ASME, 150 lb ¢ 5K CSA/FM Class III T4
3" ASME, 300 lb 5L Intrinsically Safe1) ¢ F
3" ASME, 600 lb 5M CSA/FM Class I, Div. 1, Groups A, B, C, D
4" ASME, 150 lb ¢ 5N CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q Explosion Proof Enclosure with IS Probe: ¢ G
CSA/FM Class I, Div. 1, Groups A, B, C, D
Welded flange, 316L stainless steel, CSA/FM Class II, Div. 1, Groups E, F, G
Type A flat faced CSA/FM Class III T4
DN 25, PN 16 ¢ 6A
DN 25, PN 40 6B General Purpose (CSA, FM) ¢ H
DN 40, PN 16 ¢ 6C General Purpose (CSA, FM, CE, RCM) ¢ J
DN 40, PN 40 6D ¢ We can offer shorter delivery times for configurations designated with the
DN 50, PN 16 ¢ 6E Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
DN 50, PN 40 6F
DN 80, PN 16 ¢ 6G
DN 80, PN 40 6H
DN 100, PN 16 ¢ 6J
DN 100, PN 40 6K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version, rod 350 mm (13.78 inch) ¢ A
Extended rod, length 500 mm (19.69 inch) ¢ B
Extended rod, length 750 mm (29.53 inch) ¢ C
Extended rod, length 1 000 mm (39.37 inch) ¢ D

Siemens FI 01 · 2015 4/53


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS300 - Digital - Rod with 7ML5660- Pointek CLS300 - Digital - Cable with 7ML5661-
Threaded or Flanged process connection 77 7 77 - 77 77
Threaded or Flanged process connection 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
material detection switch with optional rod/cable material detection switch with optional rod/cable
choices and configurable output. It is ideal for choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and inter- detecting liquids, solids, slurries, foam, and inter-
faces in demanding conditions where high pres- faces in demanding conditions where high pres-
sure and temperatures are present and has the sure and temperatures are present and has the
ability to tune out build-up on the probe. ability to tune out build-up on the probe.
Enclosure and Lid Click on the Article No. for the online configura-
Aluminum epoxy coated tion in the PIA Life Cycle Portal.
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A Process connection
2 x M20x1.5 cable inlet, IP65 ¢ B Threaded, 316L stainless steel
2 x ½" NPT via adapter - cable inlet, IP68 ¢ C 1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C
2 x M20x1.5 cable inlet, IP68 ¢ D 1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0D
Active shield length R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ¢ 3D
4
Standard length - ¢ 0
(125 mm threaded, 105 mm flanged) Welded flange, 316L stainless steel, raised face
Extended shield - ¢ 1
(250 mm threaded, 230 mm flanged)2) 1½" ASME, 150 lb ¢ 5D
Extended shield - ¢ 2 1½" ASME, 300 lb 5E
(400 mm threaded, 380 mm flanged)3) 1½" ASME, 600 lb 5F
1) 2" ASME, 150 lb ¢ 5G
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection 2" ASME, 300 lb 5H
2) 2" ASME, 600 lb 5J
Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)] 3" ASME, 150 lb ¢ 5K
3) 3" ASME, 300 lb 5L
Available with Probe version options C, D, and, G only
[ 750 mm (29.53 inch)] 3" ASME, 600 lb 5M
¢ We can offer shorter delivery times for configurations designated with the 4" ASME, 150 lb ¢ 5N
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. 4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q

Selection and Ordering data Order code Welded flange, 316L stainless steel,
Type A flat faced
Further designs
DN 40, PN 16 ¢ 6C
Please add "-Z" to Article No. and specify Order DN 40, PN 40 6D
code(s). DN 50, PN 16 ¢ 6E
Total insertion length: enter the total insertion length ¢ Y01 DN 50, PN 40 6F
in plain text description DN 80, PN 16 ¢ 6G
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15 DN 80, PN 40 6H
Measuring-point number/identification DN 100, PN 16 ¢ 6J
(max. 27 characters) specify in plain text
DN 100, PN 40 6K
Manufacturer's test certificate: M to DIN 55350, ¢ C11 (Note: Flange bolting patterns and facings
Part 18 and to ISO 9000 dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Probe length (length from flange face)
Operating Instructions (threaded lengths include process thread)
Note: The Operating Instructions should be See page 4/57 Note: No Y01 needed in Order code for
ordered as a separate line on the order. standard lengths
This device is shipped with the Siemens Milltronics Extended cable, 3 000 mm (118.11 inch), ¢ A
manual DVD containing the ATEX Quick Start and length can be shortened by customer
manual library.
Extended cable, 6 000 mm (236.22 inch), ¢ B
Accessories See page 4/57 length can be shortened by customer

¢ We can offer shorter delivery times for configurations designated with the Add Order code Y01 and plain text:
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. "Insertion length ... mm"
Extended cable, 500 ... 1 000 mm ¢ E
(19.69 ... 39.37 inch)
Extended cable, 1 001 ... 5 000 mm ¢ F
(39.41 ... 196.85 inch)
Extended cable, 5 001 ... 10 000 mm ¢ G
(196.89 ... 393.70 inch)
Extended cable, 10 001 ... 15 000 mm ¢ H
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm ¢ J
(590.59 ... 787.40 inch)
Extended cable, 20 001 ... 25 000 mm ¢ K
(787.44 ... 984.25 inch)

4/54 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital

Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS300 - Digital - Cable with 7ML5661- Further designs
Threaded or Flanged process connection 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order
Inverse frequency shift capacitance level and code(s).
material detection switch with optional rod/cable
choices and configurable output. It is ideal for Total insertion length: enter the total insertion length ¢ Y01
detecting liquids, solids, slurries, foam, and inter- in plain text description
faces in demanding conditions where high pres- Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
sure and temperatures are present and has the Measuring-point number/identification
ability to tune out build-up on the probe. (max. 27 characters) specify in plain text
Thermal isolator Manufacturer's test certificate: M to DIN 55350, ¢ C11
Without thermal isolator ¢ 0 Part 18 and to ISO 9000
With thermal isolator [for process connection ¢ 1
temperatures over 85 °C (185 °F)] Inspection Certificate Type 3.1 per EN 10204 ¢ C12
Wetted seals Operating Instructions
FKM ¢ 0 Note: The Operating Instructions should be See page 4/57
FFKM [for process temperatures above -20 °C (-4 °F)]¢ 1 ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
4
Probe material
manual DVD containing the ATEX Quick Start and
Bare 316L stainless steel cable, PEEK isolators and ¢ 0 manual library.
316L stainless steel cable weight
PFA coated cable, PEEK isolators and 316L ¢ 1 Accessories See page 4/57
stainless steel cable weight
¢ We can offer shorter delivery times for configurations designated with the
Approvals Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Dust Ignition Proof: ¢ B
CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
Intrinsically Safe1) ¢ C
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Intrinsically Safe1) ¢ F
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe: ¢ G
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM) ¢ H
General Purpose (CSA, FM, CE, RCM) ¢ J
Enclosure and Lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
2 x M20x1.5 cable inlet, IP65 ¢ B
2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
2 x M20x1.5 cable inlet, IP68 ¢ D
Active shield length
Standard length - ¢ 0
(125 mm threaded, 105 mm flanged)
Extended shield - ¢ 1
250 mm threaded, 230 mm flanged)2)
Extended shield - ¢ 2
(400 mm threaded, 380 mm flanged)2)
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2)
Available with Probe version options A, B and, F ... K only
[ 1 000 mm (39.7 inch)]

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/55


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Digital

Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS300 - Digital - High Temperature 7ML5662- Pointek CLS300 - Digital - High Temperature 7ML5662-
Rod version with Threaded or Flanged process Rod version with Threaded or Flanged process
connection 77 7 0 7 - 77 77 connection 7 7 7 0 7 - 77 7 7
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
material detection switch with optional rod/cable material detection switch with optional rod/cable
choices and configurable output. It is ideal for choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and inter- detecting liquids, solids, slurries, foam, and inter-
faces in demanding conditions where high pres- faces in demanding conditions where high pres-
sure and temperatures are present and has the sure and temperatures are present and has the
ability to tune out build-up on the probe. ability to tune out build-up on the probe.
Click on the Article No. for the online configura- Add Order code Y01 and plain text:
tion in the PIA Life Cycle Portal. "Insertion length ... mm"
Process connection Extended rod, factory adjusted length ¢ E
Threaded, 316L stainless steel 250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length ¢ F
¾" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0A 500 ... 749 mm (19.69 ... 29.49 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0B Extended rod, factory adjusted length ¢ G
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0C 750 ... 999 mm (29.53 ... 39.3 inch)

4 1½" NPT [(Taper), ANSI/ASME B1.20.1]


R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
¢ 0D
¢ 1A
Wetted seals
Graphite ¢ 0
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¢ 1B
Probe material
R 1½" [(BSPT), EN 10226/PT (JIS-T), ¢ 1D 316L stainless steel with ceramic (ZrO2) isolators ¢ 0
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3A Approvals
JIS B 0202] Dust Ignition Proof: ¢ B
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3B CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
JIS B 0202]
Intrinsically Safe1) ¢ C
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), ¢ 3D CE, RCM, ATEX II 1 G EEx ia IIC T6...T4,
JIS B 0202] ATEX II 1/2 D, 2 D IP6X T100 °C
Welded flange, 316L stainless steel, raised face Flameproof Enclosure with IS Probe: ¢ D
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
1" ASME, 150 lb ¢ 5A ATEX II 1/2 D T100 °C
1" ASME, 300 lb 5B Intrinsically Safe1) F
¢
1" ASME, 600 lb 5C CSA/FM Class I, Div. 1, Groups A, B, C, D
1½" ASME, 150 lb ¢ 5D CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
1½" ASME, 300 lb 5E
1½" ASME, 600 lb 5F Explosion Proof Enclosure with IS Probe: ¢ G
CSA/FM Class I, Div. 1, Groups A, B, C, D
2" ASME, 150 lb ¢ 5G CSA/FM Class II, Div. 1, Groups E, F, G
2" ASME, 300 lb 5H CSA/FM Class III T4
2" ASME, 600 lb 5J General Purpose (CSA, FM) ¢ H
3" ASME, 150 lb ¢ 5K General Purpose (CSA, FM, CE, RCM) ¢ J
3" ASME, 300 lb 5L Enclosure and Lid
3" ASME, 600 lb 5M Aluminum epoxy coated
4" ASME, 150 lb ¢ 5N 2 x ½" NPT via adapter - cable inlet, IP65 ¢ A
4" ASME, 300 lb 5P 2 x M20x1.5 cable inlet, IP65 ¢ B
4" ASME, 600 lb 5Q 2 x ½" NPT via adapter - cable inlet, IP68 ¢ C
Welded flange, 316L stainless steel, 2 x M20x1.5 cable inlet, IP68 ¢ D
Type A flat faced Active shield length
DN 25, PN 16 ¢ 6A Standard length - (125 mm threaded, 105 mm flan- ¢ 0
DN 25, PN 40 6B ged)
DN 40, PN 16 ¢ 6C Extended shield - ¢ 1
DN 40, PN 40 6D (250 mm threaded, 230 mm flanged)2)
DN 50, PN 16 ¢ 6E Extended shield - ¢ 2
(400 mm threaded, 380 mm flanged)3)
DN 50, PN 40 6F
1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe
DN 80, PN 16 ¢ 6G
protection
DN 80, PN 40 6H 2)
DN 100, PN 16 ¢ 6J Available with Probe version options B ... D, F, G only
[ 500 mm (19.69 inch)]
DN 100, PN 40 6K 3) Available with Probe version options C, D, and, G only
(Note: Flange bolting patterns and facings [ 750 mm (29.53 inch)]
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
¢ We can offer shorter delivery times for configurations designated with the
Probe length (length from flange face) Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version, rod 350 mm (13.78 inch) ¢ A
Extended rod, length 500 mm (19.69 inch) ¢ B
Extended rod, length 750 mm (29.53 inch) ¢ C
Extended rod, length 1 000 mm (39.37 inch) ¢ D

4/56 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Operating Instructions - Standard
Please add "-Z" to Article No. and specify Order English 7ML1998-5JH04
code(s).
German 7ML1998-5JH34
Total insertion length: enter the total insertion length ¢ Y01 Note: The Operating Instructions should be
in plain text description ordered as a separate line on the order.
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15 Quick Start manual, multi-language A5E32221251
Measuring-point number/identification
(max. 27 characters) specify in plain text This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Manufacturer's test certificate: M to DIN 55350, ¢ C11 Operating Instructions library.
Part 18 and to ISO 9000
Operating Instructions - Digital
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
English 7ML1998-5JJ05
Operating Instructions
French 7ML1998-5JJ11
Note: The Operating Instructions should be See page 4/57
ordered as a separate line on the order. German 7ML1998-5JJ34
This device is shipped with the Siemens Milltronics
4
Note: The Operating Instructions should be
manual DVD containing the ATEX Quick Start and ordered as a separate line on the order.
manual library.
Quick Start manual, multi-language A5E32221496
Accessories See page 4/57
This device is shipped with the Siemens Milltronics
¢ We can offer shorter delivery times for configurations designated with the manual DVD containing the ATEX Quick Start and
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. Operating Instructions library.
Accessories
One metallic cable gland M20x1.5, -40 ... +80 °C 7ML1930-1AQ
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
6 ... 12 mm (0.236 ... 0.472 inch)
M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
7 ... 12 mm (0.275 ... 0.472 inch)
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
Blind threaded flanges are available.
Please contact ceg.smpi@siemens.com with a
completed application data sheet on page 4/11
Pointek Specials See page 4/80

Siemens FI 01 · 2015 4/57


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

■ Characteristic curves
Pressure/temperature curve
CLS300 extended rod and cable probes
Threaded process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

4
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 30 bar (435 psi) at 75 °C

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)

Pressure/temperature curve
CLS300 high temperature rod probes
Threaded process connections
(7ML5652 and 7ML5662)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)

4/58 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

Pressure/temperature curve
CLS300 extended rod and cable probes
ASME flanged process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)

Permitted operating pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

4
20 bar (290 psi)

Atmospheric 10 bar (145 psi) ASME 150 lb1)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660, and 7ML5661)

Permitted operating pressures P Pressure/temperature curve


CLS300 high temperature rod probes
ASME flanged process connections
90 bar (1.305 psi) (7ML5652 and 7ML5662)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)


ASME 600 lb1)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

ASME 150 lb1)


Atmospheric 10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)

Siemens FI 01 · 2015 4/59


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

Pressure/temperature curve
CLS300 extended rod and cable probes
EN flanged process connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)

Permitted operating pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


PN 401)

4 20 bar (290 psi)

PN 161)
Atmospheric 10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)

Pressure/Temperature Curve
CLS300 High Temperature Rod Probes
EN Flanged Process Connections (7ML5652 and 7ML5662)

Permitted Operating Pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

Atmospheric 10 bar (145 psi) PN 161)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted Operating Temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)

4/60 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

■ Dimensional drawings
Rod version High temperature rod version
Threaded (7ML5650 and 7ML5660) Threaded (7ML5652 and 7ML5662)
Lid
Lid clip
2 cable entries
Electronics/ ½" NPT or
enclosure 20 (0.79)
M20 x 1.5

Thermal M20: 135 (5.32)


Y02 1)

isolator ½" NPT: 150 (5.91)


min. = 250 (9.8)/max. = 1 000 (39.37)

Lid with window

Y02 1)

min. = 250 (9.8)/max. = 1 000 (39.37)


Ceramic
Y01 (insertion length)

isolator(s)

Y01 (insertion length)


4
Measuring length

165 (6.50)
Lid without window

290 (11.42)
Probe

Measuring length

(5.91)

275 (10.83)
150
Probe

Thermal
isolator

Ø19 (0.75) Ø19 (0.75)

Cable version, non-insulated Cable version, insulated


Threaded (7ML5651 and 7ML5661) Threaded (7ML5651 and 7ML5661)
1)

Y02 1)
Y02

min. = 500 (20)/max. = 25 000 (984)

min. = 500 (20)/max. = 25 000 (984)


Y01 (insertion length)

Y01 (insertion length)

Stainless PFA insulated


Measuring length

Measuring length

steel cable cable

Ø6 (0.24) Ø10 (0.35)


250 (9.84)

250 (9.84)

Stainless Stainless
steel weight steel weight

Ø32 (1.26) Ø32 (1.26)

Note:
1)
Extended Active Shield (Y02): standard length 125 (4.92). Optional active shield lengths: 250 (9.84) or 400 (15.75).

Pointek CLS300 - Threaded Process Connections, dimensions in mm (inch)

Siemens FI 01 · 2015 4/61


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

Rod version High temperature rod version


Welded flange (7ML5650 and 7ML5660) Welded flange (7ML5652 and 7ML5662)
Lid
Lid clip

Electronics/ 2 cable entries


enclosure ½" NPT or
M20 x 1.5
Thermal M20: 135 (5.32)
isolator
Y02 1)

min. = 250 (9.8)/max. = 1 000 (39.37) ½" NPT: 150 (5.91)

Lid with window

Y02 1)

min. = 250 (9.8)/max. = 1 000 (39.37)


Ceramic
Y01 (insertion length)

isolator(s)

Y01 (insertion length)


Measuring length

185 (7.28)
4
Lid without window

273 (10.75)
Probe

Measuring length

(6.73)
171

260 (10.24)
Probe

Thermal
isolator

Ø19 (0.75) Ø19 (0.75)

Cable version, non-insulated Cable version, insulated


Welded flange (7ML5651 and 7ML5661) Welded flange (7ML5651 and 7ML5661) Flange Facing (raised face)
Flange Class Facing thickness
ASME 150/300 2 (0.08)
ASME 600/900 7 (0.28)
PN16/40 2 (0.08)
Y02 1)

1)
Y02
min. = 500 (20)/max. = 25 000 (984)

min. = 500 (20)/max. = 25 000 (984)


Y01 (insertion length)

Y01 (insertion length)

Stainless PFA insulated


Measuring length

Measuring length

steel cable cable

Ø6 (0.24) Ø10 (0.35)


250 (9.84)

250 (9.84)

Stainless Stainless
steel weight steel weight

Ø32 (1.26) Ø32 (1.26)

Note:
1)
Extended Active Shield (Y02): standard length 105 (4.13). Optional active shield lengths: 230 (9.06) or 380 (14.96).
Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above)

Pointek CLS300 - Flanged Process Connections, dimensions in mm (inch)

4/62 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS300 – Standard and Digital

■ Schematics
Wiring: Pointek CLS300 standard
White
Black
Red P2
Trip
point
(+)

(f )

Switch bank
P1 S1 K1
OFF
GND

- + 3 2 1 K4
Delay Sensor
L1 L3
Sensor Power 1 2 3
L2 status on
Output Power
status supply

4
12 to 250 V AC/DC

NC NO NO
K2 K3
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction manual or contact Siemens representative for detailed
wiring information.

Wiring: Pointek CLS300 digital

White
Reed
Test input contact*
White

Red (+)

Sensor Black (-)


Alarm output
solid-state switch Orange (f)

24 V DC/PROFIBUS PA

Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.

*Magnet activated sensor test


A magnet can be used to test the sensor without opening the lid of the
Pointek CLS300 digital version. Bring the magnet close to the test area
indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.

Pointek CLS300 connection

Siemens FI 01 · 2015 4/63


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS500 is an inverse frequency shift capacitance level falling material.
and material detection switch ideal for detecting interfaces,
solids, liquids, toxic, and aggressive chemicals in critical condi-
tions of high temperature and pressure. CLS500 also has the
ability to tune out build-up on the probe.

■ Benefits
• Active-Shield technology so measurement is unaffected by
material buildup in active shield section
• 2-wire loop powered with solid-state switch or 4 to 20/20 to
4 mA output
Build up of material in active shield area does not affect
• Simple push-button calibration and integrated local display switch operation.
• Full function diagnostics
• HART communications for remote commissioning and
inspection

■ Application
Active-Shield technology ensures that measurement is unaf-
fected by vapors, product deposits, dust and condensation. The
unique mechanical probe design coupled with a high
performance transmitter gives superior performance in a wide
range of level detection applications.
Pointek CLS500’s microprocessor-based electronics provide
one-point calibration, making setup possible without shutting
down your production process.
• Key Applications: foam or liquid/foam level, glycol regener-
ators, high-pressure coalescers, LNG applications
50 (2)

Install probe at least 50 (2) from tank wall.

Pointek CLS500 installation, dimensions in mm (inch)

4/64 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

■ Technical specifications
Input Design
Measuring range 0 ... 330 pF Material
Span Min. 1 pF • Wetted parts material
- Standard rod 316L stainless steel
Output • Probe isolation (rod) PFA
Solid-state switch Probe diameter
• Output Galvanically isolated • Standard rod version (PFA) 16 mm (0.63 inch)
• Protection Against reversed polarity (bipolar) • High temperature rod version 19 mm (0.75 inch)
• Max. switching voltage • 30 V (DC) (Stainless steel)
• 30 V peak (AC)
• Max. load current 82 mA Probe length
• Voltage drop < 1 V, typical at 50 mA • Standard rod version (PFA) Max. 1 000 mm (39.4 inch) with
16 mm (0.63 inch) diameter probe
• Time delay 1 ... 60 s
(pre or post switching) • High temperature rod version Max. measuring length 1 000 mm
(Stainless steel) (39.4 inch) with 19 mm (0.75 inch)
Current loop 4 ... 20 mA/20 ... 4 mA diameter probe

4
Accuracy (transmitter) Process connection of probe
Temperature stability 0.15 pF (0 pF) or < 0.25 % • Threaded mounting NPT [(Taper), ANSI/ASME B1.20.1]
(typical < 0.1 %) of actual measure- R [(BSPT), EN 10226/PT (JIS-T),
ment value, whichever is greater JIS B 0203]
over the full temperature range G [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Non-linearity and repeatability 0.1 % of full scale and actual • Flange mounting ASME, EN 1092-1
measurement respectively
Enclosure
Accuracy Deviation < 0.1 % of measured value • Material Aluminum, epoxy-coated (Stainless
Rated operating conditions1) steel option available.
Contact ceg.smpi@siemens.com)
Installation conditions • Cable inlet 2 x ½" NPT
- Location Indoor/outdoor • Degree of protection Type 4X/NEMA4X/IP65, IP68
Ambient conditions Power supply Max. 33 V DC
• Ambient temperature (transmitter) -40 ... +85 °C (-40 ... +185 °F)2)
• Installation category I Features
• Pollution degree 4 Measurement current signaling NAMUR NE 43
Medium conditions Safety • Inputs/outputs fully galvanically
• Relative dielectric constant r Min. 1.5 isolated
• Polarity-insensitive current loop
• Process temperature Temperature ratings are pressure
• Fully potted
dependent.
• Integrated safety barrier
See Pressure/Temperature curves
on page 4/72. • Diagnostics with fault alarm when: Primary variable (PV) out of limits,
system failure in measurement circuit,
- Standard (PFA) -50 ... +200 °C (-58 ... +392 °F)
deviation between A/D and D/A con-
- High temperature stainless steel -60 ... +400 °C (-76 ... +752 °F) verter, check sum, watch dog and
version with thermal isolator self-checking facility
- Cryogenic version -200 ... +200 °C (-328 ... +392 °F) • Function rotary switch Positions 0 ... 9, A ... F
Contact ceg.smpi@siemens.com • SMART communication Conforming to HART Communication
for details. Foundation (HCF)
Process pressure Pressure rating of process seal is Certificates and approvals
temperature dependent. • General Purpose CE, CSA/FM, RCM
See Pressure/Temperature curves
on page 4/72. • Non incendive/Non sparking CSA/FM Class I, Div. 2,
Groups A, B, C, D T4
• Standard (PFA) -1 ... +150 bar g ATEX II 3G 2D EEx n A [ib] IIC
(-14.6 ... +2 175 psi g) T6 ... T4 T100 °C
• High temperature version -1 ... +35 bar g • Dust Ignition Proof CSA/FM Class II and III, Div. 1,
(Stainless steel) (-14.6 ... +507.6 psi g) Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] T6 ... T1
T100 °C
• Explosion Proof FM Class 1, Div. 1,
Groups A, B, C, D T4
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1
T100 °C
• Marine Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3,
ENV5, Bureau Veritas
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 4/72.
2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)

Siemens FI 01 · 2015 4/65


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Pointek CLS500 probe version Standard HT Series
Process connection types Standard (PFA) High Temperature
(7ML5601, 7ML5602, 7ML5603) (Stainless steel) (7ML5604)
Threaded Available as standard –
Flange Available as standard Available as standard
Process connection materials
316L stainless steel Available as standard Available as standard
Probe insulation
None – HT Stainless: available as standard
PFA Available as standard –
Length parameters
Max. rod length 1 000 mm (40 inch) 1 000 mm (40 inch)
Process condtitions1)
Max. process pressure 150 bar g (2 175 psi g) Stainless steel:2) 35 bar g (507 psi g)

4 Max. process temperature


1)
200 °C (392 °F) 400 °C (752 °F)

When operation is in areas classified as hazardous, observe restrictions according to relevant certificate.
See also Pressure/Temperature curves on page 4/72. Pressure rating of process seal is temperature dependent.
2)
Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page 4/72.
– Not available as standard

4/66 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS500, threaded 7ML5601- Further designs
Inverse frequency shift capacitance level and
77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order
material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in code(s).
critical conditions of extreme temperature and Total insertion length: enter the total insertion length Y01
pressure. CLS500 also has the ability to tune out in plain text description
build-up on the probe.
Active Shield length - minimum length is 50 mm Y02
Click on the Article No. for the online configura- Y02: to mm1)
tion in the PIA Life Cycle Portal.
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Electronic transmitter Measuring-point number/identification
No transmitter supplied 0 (max. 27 characters) specify in plain text
MSP 2002-1 (330 pF) 1 Manufacturer's test certificate: M to DIN 55350, C11
Process connection Part 18 and to ISO 9000
¾" A Inspection Certificate Type 3.1 per EN 10204 C12
1" B
Operating Instructions
1¼" C

4
Note: The Operating Instructions should be See page 4/71
1½" D ordered as a separate line on the order.
2" E This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Threaded connection and rating manual library.
NPT [(Taper), ANSI/ASME B1.20.1] A
R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203] B Pointek Specials See page 4/71
G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] D 1)
See dimension drawings on page 4/77 for further explanation of Y02
Probe insulation/material of process connection
PFA insulation/316L stainless steel 1
Approvals
General Purpose: CE, CSA/FM, RCM 1
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div. 1, Groups A, B, C, D T4 6
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, minimum insertion 1
length 200 mm (7.9 inch), maximum insertion
length 1 000 mm (39.4 inch)1)
Thermal isolator/remote version
Rigid thermal isolator [for process connection A
temperature over 85 °C (185 °F)]
No thermal isolator B
1)
Add Order code Y01 and Y02 in plain text:
"Insertion/active shield length to mm"

Siemens FI 01 · 2015 4/67


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS500, welded flange 7ML5602- Further designs
Inverse frequency shift capacitance level and Please add "-Z" to Article No. and specify Order
77 7 77 - 77 A 0
material detection switch for detecting interfaces, code(s).
solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and Total insertion length: enter the total insertion length Y01
pressure. CLS500 also has the ability to tune out in plain text description
build-up on the probe. Active Shield length - minimum length is 50 mm. Y02
Click on the Article No. for the online configura- Y02: to mm1)
tion in the PIA Life Cycle Portal. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Electronic transmitter Measuring-point number/identification
MSP 2002-1 (330 pF) 1 (max. 27 characters) specify in plain text

Process connection and pressure rating Manufacturer's test certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Welded flange, 316L stainless steel, raised face
2" ASME, 150 lb AA Inspection Certificate Type 3.1 per EN 10204 C12
2" ASME, 300 lb AB Operating Instructions
3" ASME, 150 lb BA
Note: The Operating Instructions should be See page 4/71
4 3" ASME, 300 lb1)
4" ASME, 150 lb1)
BB
CA
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
4" ASME, 300 lb1) CB manual library.
6" ASME, 150 lb1) DA Pointek Specials See page 4/71
6" ASME, 300 lb1) DB
1) See dimensional drawings on page 4/77 for further explanation of Y02
Welded flange, 316L stainless steel,
Type A flat faced
DN 50 PN 16 EC
DN 50 PN 40 ED
DN 80 PN 16 FC
DN 80 PN 40 FD
DN 100 PN 161) GC
DN 125 PN 161) HC
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe insulation/material of process connection
PFA insulation/316L stainless steel 1
Approvals
General Purpose 1
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div. 1, Groups A, B, C, D T4 6
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, min. length 200 mm 1
(7.9 inch), max. length 1 000 mm (39.4 inch)
Thermal isolator
Rigid thermal isolator A
[for process temperature over 85 °C (185 °F)]
No thermal isolator B
1)
Custom shipping methods required. Contact factory for more details.

4/68 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek CLS500, single piece flange 7ML5603- Further designs
Inverse frequency shift capacitance level and 77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order
material detection switch for detecting interfaces, code(s).
solids, liquids, toxic and aggressive chemicals in Total insertion length: enter the total insertion length Y01
critical conditions of extreme temperature and in plain text description
pressure. CLS500 also has the ability to tune out
build-up on the probe. Active Shield length - minimum length is 50 mm. Y02
Y02: to mm1)
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
Electronic transmitter (max. 27 characters) specify in plain text
MSP 2002-1 (330 pF) 1
Manufacturer's test certificate: M to DIN 55350, C11
Process connection and pressure rating Part 18 and to ISO 9000
Single piece flange, 316L stainless steel,
raised face Inspection Certificate Type 3.1 per EN 10204 C12
2" ASME, 150 lb AA Operating Instructions
2" ASME, 300 lb AB Note: The Operating Instructions should be See page 4/71
3" ASME, 150 lb
3" ASME, 300 lb1)
BA
BB
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics 4
manual DVD containing the ATEX Quick Start and
4" ASME, 150 lb1) CA manual library.
4" ASME, 300 lb1) CB Accessories See page 4/71
6" ASME, 150 lb1) DA 1)
See dimensional drawings on page 4/77 for further explanation of Y02
6" ASME, 300 lb1) DB
Single piece flange, 316L stainless steel,
Type B1 raised faced
DN 50 PN 16 EC
DN 50 PN 25 ED
DN 80 PN 16 FC
DN 80 PN 25 FD
DN 100 PN 161) GC
DN 100 PN 251) GD
DN 125 PN 161) HC
DN 125 PN 251) HD
Probe insulation/material of process connection
PFA insulation/316L stainless steel 1
Approvals
General Purpose: CE, CSA/FM, RCM 1
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div. 1, Groups A, B, C, D T4 6
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, 1
maximum length 1 000 mm (39.4 inch) (Y01)
Thermal isolator
Rigid thermal isolator [for process connection A
temperature over 85 °C (185 °F)]
No thermal isolator B
1)
Custom shipping methods required. Contact factory for more details

Siemens FI 01 · 2015 4/69


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data Article No. Selection and Ordering data Article No.
Pointek CLS500 High temperature 7ML5604- Pointek CLS500 High temperature 7ML5604-
Inverse frequency shift capacitance level and 7A 7 77 - 7777 Inverse frequency shift capacitance level and 7 A 7 77 - 7777
material detection switch for detecting interfaces, material detection switch for detecting interfaces,
solids, liquids, toxic and aggressive chemicals in solids, liquids, toxic and aggressive chemicals in
critical conditions of extreme temperature and critical conditions of extreme temperature and
pressure. CLS500 also has the ability to tune out pressure. CLS500 also has the ability to tune out
build-up on the probe. build-up on the probe.
Click on the Article No. for the online configura- Probe material of process connection
tion in the PIA Life Cycle Portal.
No insulation/316L stainless steel3)4) 1
Electronic transmitter
Stilling well
MSP 2002-1 (330 pF) 1
No stilling well 0
Process connection and pressure rating
Approvals
316L stainless steel, raised face1)
General Purpose A
2" ASME, 150 lb A1
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; B
2" ASME, 300 lb A2 ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
2" ASME, 600 lb A3 CSA/FM Class II and III Div. 1, Groups E, F, G T4
4 2" ASME, 900 lb A4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C D
3" ASME, 150 lb B1 FM Class I, Div. 1, Groups A, B, C, D T4 F
3" ASME, 300 lb2) B2
Probe/electrode diameter
3" ASME, 600 lb2) B3
Maximum length 1 000 mm (39.37 inch)4) A
3" ASME, 900 lb2) B4
Thermal isolator
4" ASME, 150 lb2) C1
Rigid thermal isolator [for process connection 1
4" ASME, 300 lb2) C2 temperature over 85 °C (185 °F)]
4" ASME, 600 lb2) C3
1)
4" ASME, 900 lb2) C4 Welded flange for no insulation option only
2)
Custom shipping methods required
6" ASME, 150 lb2) D1
3)
6" ASME, 300 lb2) D2 Non-conductive material only, stainless steel non-insulated probe diameter
19 mm (0.75 inch)
6" ASME, 600 lb2) D3 4)
Add Order code Y01 and Y02 in plain text:
6" ASME, 900 lb2) D4 "Insertion/active shield length to mm"
316L stainless steel, Type B1 flat faced Minimum insertion length depends on probe version selected.
See dimensional drawings on page 4/77 for more details.
DN 50 PN 16 E1
DN 50 PN 25 E2
DN 50 PN 40 E3
DN 50 PN 63 E4
DN 80 PN 16 F 1
DN 80 PN 25 F 2
DN 80 PN 402) F 3
DN 80 PN 632) F 4
DN 100 PN 162) G1
DN 100 PN 252) G2
DN 100 PN 402) G3
DN 100 PN 642) G4
DN 125 PN 162) H1
DN 125 PN 252) H2
DN 125 PN 402) H3
DN 125 PN 642) H4
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)

4/70 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: enter the total insertion length Y01
in plain text description
Active Shield length - minimum length is 50 mm. Y02
Y02: to mm1)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's test certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Operating Instructions Article No.

4
English 7ML1998-5GG03
German 7ML1998-5GG32
French 7ML1998-5GG11
Dutch 7ML1998-5GG41
Note: The Operating Instructions should be
ordered as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Quick Start manual, multi-language A5E32243995
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
6 ... 12 mm (0.236 ... 0.472 inch)
M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
7 ... 12 mm (0.275 ... 0.472 inch)
Transmitter, MSP 2002-1, 330 PF 7ML1830-1JP
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
Pointek Specials See page 4/80
1) See dimensional drawings on page 4/77 for further explanation of Y02

Siemens FI 01 · 2015 4/71


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

■ Characteristic curves
Pressure/temperature curve
CLS500 rod probes
Threaded process connections
(7ML5601)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

4 120 bar (1.740 psi)

110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

Atmospheric 10 bar (145 psi)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC)(-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 137 bar (1988 psi) at 75 °C

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5601)

4/72 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

Pressure/temperature curve
CLS500 rod probes
ASME flanged process connections
(7ML5602 and 7ML5603)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

120 bar (1.740 psi)


4
110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

ASME 150 lb1)


Atmospheric 10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC)(-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)

Siemens FI 01 · 2015 4/73


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

Pressure/temperature curve
CLS500 rod probes
EN flanged process connections
(7ML5602 and 7ML5603)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

120 bar (1.740 psi)


4
110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)


PN 251)

Atmospheric
10 bar (145 psi) PN 161)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC)(-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)

4/74 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

Pressure/temperature curve
CLS500 high temperature (no insulation)
ASME flanged process connections
(7ML5604)

Permitted operating pressures P

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)


4
1)
ASME 600 lb
50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

ASME 150 lb1)


Atmospheric 10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

Siemens FI 01 · 2015 4/75


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

Pressure/temperature curve
CLS500 high temperature (no insulation)
EN flanged process connections
(7ML5604)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

PN 251)

4 Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
PN 161)

(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

4/76 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

■ Dimensional drawings
Standard rod version
Threaded (7ML5601) Standard configuration
(7ML5601)

205 (8.1)
Transmitter/
electronics

20 (0.79) 1/2" NPT:


230 (9.1)
Y02

min. = 200 (7.87) / max. = 1 000 (39.37)

With explosion-proof seal option With thermal isolator option


(all versions) (all versions)
4
Y01 (insertion length)
Measuring length

270 (10.6)
PFA insulated

430 (16.9)
probe Thermal
30 (1.18)

isolator

Inactive tip

Ø16 (0.63)

Pointek CLS500 - Threaded Process Connections, dimensions in mm (inch)

Siemens FI 01 · 2015 4/77


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

Standard Rod version


Standard configuration
Welded Flange (7ML5602)
(7ML5602, 7ML5603)
Single Piece Flange (7ML5603)

205 (8.1)
Transmitter/
electronics

½" NPT:
230 (9.1)
Y021)

With explosion-proof seal option With thermal isolator option


min. = 200 (7.87)/max. = 1 000 (39.37)

(all versions) (all versions)


Y01 (insertion length)

270 (10.6
4
Measuring length1)

430 (16.9)
PFA insulated Thermal
probe isolator
30 (1.18)

Inactive tip
Ø16 (0.63)

High temperature rod version


Welded Flange (7ML5604), Stainless steel rod 4)

Flange Facing (raised face)


Flange Class Facing thickness
ASME 150/300 2 (0.08)
ASME 600/900 7 (0.28)
Thermal
isolator PN16/25/40/64 2 (0.08)

Notes:
1)
Min. Y02 (active shield length) = 50 (1.96)
2)
Min. Y02 (active shield length) = 105 (4.13)
3)
Min. Y02 (active shield length) = 100 (3.94)
4)
Non conductive materials only

Insertion length does not include any raised


min. = 200 (7.87)/max. = 1 000 (39.37)

face/gasket face dimension (see Flange


Facing Table above)
Y02 2)
Y01 (insertion length)
Measuring

Stainless steel
length2)

probe

Ø19 (0.75)

Pointek CLS500 - Flanged Process Connections, dimensions in mm (inch)

4/78 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS500

■ Schematics
Ground lug

Protective
label
Solid state
switch relay
(any polarity)
Instrument
system
ground 4 ... 20 mA
current loop
connection
Measuring Type:
Ser.: (any polarity)
signal Date:
Rev.:
(mini- Tampering voids warranty

coaxial
cable)

4
Ground connection
point for instrument
system

Pointek CLS500 connections

Siemens FI 01 · 2015 4/79


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS Specials

■ Selection and ordering data


Pointek Specials1) Pointek Specials1)
Article No. Article No.
CLS100 Polycarbonate Lid and Gasket, FKM Kit, Sensor for cable units, PPS, Digital, A5E01163678
FKM
Kit, Sensor for cable units, PPS, Standard, A5E01163679
FFKM
Kit, Sensor for cable units, PPS, Digital, A5E01163680
FFKM
Kit, Sensor for cable units, PVDF, Standard, A5E01163681
Kit, Lid and gasket, A5E01163671 FKM
CLS100 enclosure version
Kit, Sensor for cable units, PVDF, Digital, A5E01163682
CLS100 Miscellaneous Parts FKM
Custom length of cable is available only for Kit, Sensor for cable units, PVDF, Standard, A5E01163683
7ML5501-xxx1x and 7ML5501-xxx5x2) FFKM

4 CLS200 Gasket (IP65), Synprene Kit, Sensor for cable units, PVDF, Digital,
FFKM
A5E01163684

CLS200 Mounting Bracket,


316L stainless steel

Spare gasket, enclosure version A5E01163672


(IP65 versions only)
CLS200 Gasket (IP68), Silicone

Spare mounting bracket A5E01163685


CLS200 PROFIBUS Connector (IP65)

Spare gasket, enclosure version A5E01163673


(IP68 versions)
CLS200 Blind Lid Spare, PROFIBUS connector A5E01163686
(IP65 versions only)
CLS200 Miscellaneous Parts
CLS200 with FFKM O-rings (any version)2)
CLS200 Electronics
Test magnet, digital version 7ML1830-1JE
Spare aluminum blind lid A5E01163674 Amplifier/power supply kit, standard version A5E03251681
(for standard versions only) Amplifier/power supply, digital version 7ML1830-1JF
CLS200 Lid with window LCD display, digital version 7ML1830-1JK
CLS300 Cable Extensions,
316L stainless steel

Spare aluminum lid with window A5E01163676


CLS200 Sensor Kit for cable units Kit, stainless steel cable extension, 1 m, A5E01163688
adjustable by customer
Kit, stainless steel cable extension, 3 m, A5E01163689
adjustable by customer
Kit, stainless steel cable extension, 5 m, A5E01163690
adjustable by customer
Kit, stainless steel cable extension, 10 m, A5E01163691
Kit, Sensor for cable units, PPS, Standard, FKM A5E01163677 adjustable by customer
Kit, stainless steel cable extension, 15 m, A5E01163693
adjustable by customer
Kit, stainless steel cable extension, 20 m, A5E01163695
adjustable by customer

4/80 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Capacitance switches
Pointek CLS Specials
Pointek Specials1) Pointek Specials1)
Article No. Article No.
CLS300 Cable Extensions, CLS300 Electronics Kits with drivers
316 stainless steel with PFA coating (for rod or cable versions)

Kit, Electronics with driver, standard CLS300. A5E01163723


To be used in rod or cable versions with
length less than 5 m.3)4)

Kit, PFA cable extension, 1 m, Kit, Electronics with driver, digital CLS300. A5E01163725
A5E01163697
adjustable by customer To be used in rod or cable versions with
length less than 5 m.3)4)
Kit, PFA cable extension, 3 m, A5E01163698
adjustable by customer CLS300 Electronics Kits with drivers
(for cable versions)
Kit, PFA cable extension, 5 m, A5E01163699
adjustable by customer
Kit, PFA cable extension, 10 m,
adjustable by customer
A5E01163700
4
Kit, PFA cable extension, 15 m, A5E01163701 Kit, Electronics with driver, standard CLS300. A5E01163724
adjustable by customer To be used in cable versions with
length greater than 5 m.3)4)
Kit, PFA cable extension, 20 m, A5E01163702
adjustable by customer Kit, Electronics with driver, digital CLS300. A5E01163726
To be used in cable versions with
CLS300 Rod Kits, 316L stainless steel length greater than 5 m.3)4)
CLS300 Electronics
Test magnet, digital version 7ML1830-1JE
Amplifier/power supply kit, standard version A5E03251683
Amplifier/power supply, digital version 7ML1830-1JF
LCD display, digital version 7ML1830-1JK
Kit, stainless steel rod 180 mm (7.09 inch) to A5E01163719
be used with CLS300 units only (with standard CLS300 Weight Kit, 316L stainless steel
active shield). Insertion length after installation
is 350 mm (13.78 inch).
Kit, stainless steel rod 330 mm (12.99 inch) to A5E01163720
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 500 mm (19.69 inch).
Kit, stainless steel rod 580 mm (22.83 inch) to A5E01163721
be used with CLS300 units only (with standard Kit, Spare stainless steel weight. To be used in A5E01163727
active shield). Insertion length after installation any cable version of CLS300
is 750 mm (29.53 inch). CLS500 Gasket (IP65), Silicone
Kit, stainless steel rod 830 mm (32.68 inch) to A5E01163722
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 1 000 mm (39.37 inch).
Kit, stainless steel rod 1 330 mm (52.36 inch) to
be used with CLS300 units only (with standard Spare gasket, CLS500 enclosure version, IP65 A5E01163728
active shield). Insertion length after installation
is 1 500 mm (59.06 inch).2) CLS500 Blind Lid
Kit, stainless steel rod 1 830 mm (72.05 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 2 000 mm (78.74 inch).2) Spare CLS500 aluminum blind lid A5E01163729

Kit, stainless steel rod customized length CLS500 Electronics Kit


up to 1 m2) Transmitter, MSP 2002-1, 330 PF 7ML1830-1JP
Kit, stainless steel rod customized length 1) Special flange sizes and facings are available. Please contact
up to 2 m2) ceg.smpi@siemens.com for part number and pricing. Submit Application
Questionnaire found on page 4/11.
2) Please contact ceg.smpi@siemens.com for part number and pricing.
3) For General Purpose approvals only.
4) To maintain approvals, qualified trained Siemens personnel
required for part replacement.
Please contact ceg.smpi@siemens.com for special requests.

Siemens FI 01 · 2015 4/81


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100

■ Overview ■ Configuration
Horizontal mounting

Switching point

Switching point
(recommended mounting
position, particularly for
adhesive applications)

Vertical mounting

Switching point
with

4 lower density

13 (0.51)
13 (0.51)
SITRANS LVL100 is a compact vibrating level switch for material
detection in liquid and slurry applications such as overflow, high,
low and demand applications, as well as pump protection. Switching point
[approx. 13 (0.51)]
It is ideal for use in confined spaces.

■ Benefits
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57 inch) for confined Switching point
space applications with
higher density
• Fault monitoring for corrosion, loss of vibration, or line break to
the piezo drive
• Integrated test function to confirm correct operation

■ Application Horizontal mounting in 30 (1.18)


viscous or adhesive
SITRANS LVL100 is a compact level switch designed for indus- applications
trial use in all areas of process technology and can be used for
material detection with liquids and slurries. With an insertion
length of only 40 mm (1.57 inch), SITRANS LVL100 can be
mounted in small pipes and confined space applications. It is
virtually unaffected by the chemical and physical properties of
the liquid. The LVL100 can be used in difficult conditions includ- Moisture protection NOTE:
ing turbulence, air bubbles, foam generation, buildup, or exter- Welded socket for flush
nal vibration. mount optional.
The tuning fork is piezoelectrically energized and vibrates at a
mechanical resonance frequency of approximately 1 200 Hz.
Ensure cable gland faces
The vibration frequency changes when the tuning fork is cov- downward to avoid water
ered by the medium. This change is detected by the integrated ingress.
oscillator and converted into a switching command. The inte-
grated electronics evaluate the level signal and output a switch-
ing signal to connected devices.
• Key Applications: For use in liquids and slurries, for level
measurement, overfill, and dry run protection

SITRANS LVL100 Installation, dimensions in mm (inch)

4/82 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100

■ Technical specifications ■ Options


Mode of operation
Measuring principle Vibrating point level switch LVL100 threaded welded socket

Input G¾" A/316L G1" A/316L

Measured variable High and low and demand


32 (1.26) 39 (1.54)
Output G¾" G1"
Output options Contactless electronic switch
Transistor output PNP

(1.16)
(1.26)

29.5
Measuring Accuracy

32
• Hysteresis Approx. 2 mm (0.08 inch) with
vertical installation
• Switching delay Approx. 500 ms (on/off) 53 (2.09) 60 (2.36)
• Frequency Approx. 1 200 Hz
Rated operating conditions SITRANS LVL100 welded socket, dimensions in mm (inch)
Installation conditions
• Location
Ambient conditions
Indoor/outdoor
4
• Ambient temperature -40 ... +70 °C (-40 ... +158 °F)
• Installation category III
• Pollution degree 2
Medium conditions
• Temperature
- Standard -40 ... +100 °C (-40 ... +212 °F)
- High temperature option -40 ... +150 °C (-40 ... +302 °F)
• Pressure (vessel) -1 ... 64 bar g (-14.5 ... 928 psi g)
• Density 0.7 ... 2.5 g/cm³
(0.025 ... 0.09 lb/in³)
Design
Material
• Enclosure 316L and Plastic PEI
• Tuning fork 316L (1.4404 or 1.4435)
• Process connection (threaded) 316L (1.4404 or 1.4435)
• Process seal Klingersil C-4400
Process connection
• Pipe thread, cylindrical G ½" A, G ¾" A or G 1" A
(ISO 228 T1)
• Pipe thread, tapered ½" NPT, ¾" NPT or 1" NPT
• Hygienic fittings Bolting DN 40 PN 40
Tri-clamp 1", 1½", 2" PN 10
Degree of protection IP65/Type 4/NEMA 4
(with DIN 43650 valve plug),
IP66/67 or IP68
(with M12 connector)
Conduit entry 1 x M12 [IP66/IP67 or IP68 (0.2 bar)]
Weight (housing) 250 g (9 oz)
Power supply
Supply voltage 20 ... 253 V AC, 50/60 Hz
20 ... 253 V DC
Power consumption Max. 0.5 W
Certificates and approvals • Overfill protection (WHG)
• Shipping approvals

Siemens FI 01 · 2015 4/83


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LVL100 7ML5745- Further designs
Compact vibrating level switch for use in liquid and
77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection. code(s).
Ideal for use in confined spaces. Cleaning including certificate W01
Click on the Article No. for the online configura- (oil, grease and silicone free)
tion in the PIA Life Cycle Portal. Identification Label, foil laser marking ¢ Y16
Approvals Acceptance test certificate 3.1 for instrument ¢ C12
Without approvals ¢ 1
Shipping approvals5) ¢ 2 Acceptance test Certificate 2.2 for material ¢ C15
EN10204
Overfill protection (WHG)1) ¢ 3
Additional Operating Instructions Article No.
Process temperature
Standard -40 ... +100 °C (-40 ... +212 °F)2) ¢ A LVL100 (Contactless electronic switch)
Extended -40 ... +150 °C (-40 ... +302 °F)2) ¢ B • English 7ML1998-5KN01
Hygienic applications -40 ... +150 °C C
(-40 ... +302 °F)3) • French 7ML1998-5KN11

4 Process connection
Thread G¾" A PN 64/316L ¢ A0
• Spanish
• German
7ML1998-5KN21
7ML1998-5KN31
Thread G¾" A PN 64/316L Ra < 0.8 µm A1
LVL100 (Transistor PNP)
Thread ¾" NPT PN 64/316L ¢ A2
• English 7ML1998-5KP01
Thread ¾" NPT PN 64/316L Ra < 0.8 µm A3
Thread G1" A PN 64/316L ¢ A4 • French 7ML1998-5KP11
Thread G1" A PN 64/316L Ra < 0.8 µm A5 • Spanish 7ML1998-5KP21
Thread 1" NPT PN 64/316L ¢ A6 • German 7ML1998-5KP31
Thread 1" NPT PN 64/316L Ra < 0.8 µm A7 This device is shipped with the Siemens
Tri-Clamp 1" PN 16 DIN 32676/316L Ra < 0.8 µm A8 Milltronics manual DVD containing the Operating
Tri-Clamp 1½" PN 16 DIN 32676/316L Ra < 0.8 µm B0 Instructions library.
Tri-Clamp 2 " PN 16 DIN 32676/316L Ra < 0.8 µm B1 Spare Parts
Bolting DN25 PN 40 DIN 11851/316L Ra < 0.8 µm B2 LVL100 Threaded Welded Socket
Bolting DN40 PN 40 DIN 11851/316L Ra < 0.8 µm B3 G¾" A/316L with FKM Seal 7ML1930-1EE
Bolting DN50 PN 25 DIN 11851/316L Ra < 0.8 µm B4
SMS DN38 PN 6 316L Ra < 0.8 µm B5 G1" A/316L with FKM Seal 7ML1930-1EF
Hygienic fitting with compression nut F40 B6 M27x1.5/316L with FKM Seal 7ML1930-1EG
PN 25/316L Ra < 0.8 µm G¾" A/316L with EPDM Seal 7ML1930-1EH
Thread G½" (DIN 3852-A) PN64 / 316L C0 G1" A/316L with EPDM Seal 7ML1930-1EJ
Thread G½" (DIN 3852-A) PN64 / 316L Ra < 0.8 µm C1 M27x1.5/316L with EPDM Seal 7ML1930-1EK
Thread ½" NPT (ASME B1.20.1) PN 64/316L C2
¢ We can offer shorter delivery times for configurations designated with the
Thread ½" NPT (ASME B1.20.1) PN 64/316L C3 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Ra < 0.8 µm
Electronics
Contactless electronic switch 20 ... 250 V AC/DC4) ¢ 1
Transistor output PNP 10 ... 55 V DC ¢ 2
Housing
316L ¢ 1
Electrical connection/Protection
M12x1/IP67 ¢ A
According to DIN 43650 including plug/IP65 B
Acc. to DIN 43650 incl. plug with QuickOn C
connection/IP65
M12x1 incl. 5 m cable/IP68 (0.2 bar) D
1)
Available with process connection A0, A2, A4, and A6 only
2)
Available with process connection A1, A3, A5, and A7 ... B6 only
3)
Available with Electrical connection/Protection option B and C only
4)
Available with Process Temperature option A only
5) Available with Process Temperature option A only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/84 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100

■ Characteristic curves
Ambient temperature to process temperature dependency
(standard version)

70 ºC
Ambient temperature in °C (°F)

(158 ºF)

50 ºC
(122 ºF)

4
0 ºC
(32 ºF)

-40 ºC
(-40 ºF)
-40 ºC -20 ºC 0 ºC 20 ºC 40 ºC 60 ºC 80 ºC 100 ºC
(-40 ºF) (-4 ºF) (32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF)

Process temperature in °C (°F)

Ambient temperature to process temperature dependency


(high temperature version)

70 ºC
Ambient temperature in °C (°F)

(158 ºF)

0 ºC
(32 ºF)

-40 ºC
(-40 ºF)
-40 ºC -20 ºC 0 ºC 20 ºC 40 ºC 60 ºC 80 ºC 100 ºC 120 ºC 140 ºC 150 ºC
(-40 ºF) (-4 ºF) (32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF) (248 ºF) (284 ºF) (302 ºF)

Process temperature in °C (°F)

SITRANS LVL100 Ambient Temperature/Process Temperature derating curves

Siemens FI 01 · 2015 4/85


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100

■ Dimensional drawings
SITRANS LVL100 (standard) SITRANS LVL100 (extended high temperature)
{™Œˆ‹GnG¾“, G 1“ A {™Œˆ‹GnG½ A Thread G ¾” A, G 1“ A Tri-clamp (valve plug DIN 43650)
(DIN ISO 228/1) , (DIN ISO 228/1), (DIN ISO 228/1),
¾” NPT or 1” NPT ½ NPT ¾” NPT or 1” NPT
(valve plug ISO 4400) (valve plug ISO 4400) (valve plug DIN 43650)

36 (1.42) 36 (1.42)

27 (1.06) 27 (1.06)

35 (1.38) 35 (1.38)

~ 88 (3.46)

~ 101 (3.98)
4
Ø 31.7
(1.25)

Ø 31.7 Ø 31.7
158 (6.22)

156 (6.14)

(1.25) 32 (1.25)
32 (1.26) 32
(1.26)
G ¾“ A,
G ¾“ A,
¾“ NPT
¾“ NPT
G 1“ A, G ½“ A, G 1“ A,
1“ NPT ½“ NPT 1“ NPT
Ø 21.3 Ø 17 L Ø 21.3 (0.84)
L L 40 (1.57) L
(0.84) (0.67)
40 (1.57) 38 (1.5)
Switching Switching Switching
point point point

11 (0.43) 13 (0.51)
13 (0.51) L=
L= L= Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G ¾” A, ¾” NPT: 66 (2.6) Length with G ½” A, ½” NPT: 62 (2.4) Length with G 1“ A, 1” NPT: 69 (2.7)
Length with G 1“ A, 1” NPT: 69 (2.7) Length with Tri-clamp: 53 (2.1)

SITRANS LVL100 (standard with M12 connector) SITRANS LVL100 (extended, high temperature)
Bolting DIN 11851 SMS 1145
(valve plug DIN 43650) (valve plug DIN 43650)

10 (0.39) 10 (0.39)
M12 x 1 M12 x 1

Ø 31.7 Ø 31.7 SW 32
~ 105 (4.13)
~ 115 (4.53)

(1.25) (1.25) (1.26)


158 (6.22)

130 (5.14)

32

G ¾“ A, ¾“ NPT G½ A,
G 1“ A, 1“ NPT ½“ NPT
65 (1.26)

L Ø 21.3 (0.84) 17 (0.67)


40 (1.57)
(1.5)

L
38

40(1.57) Switching Switching L Switching


point point
point

13 (0.51) XXGOWU[ZP
13 (0.51)

L= L= L=
Length with G ¾” A, ¾” NPT: 66 (2.6) Length with G ½” A, ½” NPT: 62 (2.4) Length with bolting: 53 (2.1)
Length with G 1“ A, 1” NPT: 69 (2.7) Length with SMS 1145: 53 (2)

SITRANS LVL100, dimensions in mm (inch)

4/86 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL100

■ Schematics
Transistor PNP (M12 x 1 plug connection) Transistor PNP (with valve plug DIN 43650)

1 2 1 4 2 3 2 3
Max. Min.
Max. Min.

2 1 2 1

1 2 1 2

3 4 3 4
3 3 4
RL RL RL

RL

10 ... 55 V DC 10 ... 55 V DC 10 ... 55 V DC 10 ... 55 V DC

PA (Potential equalization) PA

Contactless electronic switch (valve plug DIN 43650)

Max. Min.

1 2 1 2
3 3

RL

RL

L1 N L1 N

PE (protective ground) PE

SITRANS LVL100, connections

Siemens FI 01 · 2015 4/87


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Overview ■ Configuration
Horizontal mounting Marked with screwed version on top,
with flange versions directed to the
flange holes
Switching point
(recommended
mounting position,
particularly for
adhesive applications)

Vertical mounting

4 Switching point
with lower
density

SITRANS LVL200 is a standard vibrating level switch for material


detection in liquid and slurry applications such as overflow, high,
low, and demand applications, as well as pump protection.
For use in SIL-2 applications. Switching point Switching point
[approx. [approx.
13 (0.51)] 27 (1.06)]
■ Benefits
• Proven vibrating level switch technology for liquids Switching point
with higher
• Compact insertion length of 40 mm (1.57 inch) for confined density
space applications
• Fault monitoring for corrosion, loss of vibration or line break to
the piezo drive
• Functional Safety (SIL 2). Device suitable for use in accor-
dance with IEC 61508 and IEC 61511
• Hygienic process connections
Mount away from filling
■ Application openings or agitators.

SITRANS LVL200 is a level switch designed for industrial use in


all areas of process technology and can be used with liquids
and slurries. With a tuning fork insertion length of only 40 mm
(1.57 inch), SITRANS LVL200 can be mounted in small pipes
and applications with confined space. The LVL200 can be used
to measure products with a minimum density of > 0.5 g/cm³
(0.018 lb/in³). The LVL200 can be used in difficult conditions
including turbulence, air bubbles, foam generation, buildup,
or external vibration.
SITRANS LVL200 continuously monitors faults via frequency
evaluation, providing early detection of strong corrosion or dam- Moisture protection
age on the tuning fork, loss of vibration, or a line break to the
piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its
mechanical resonance frequency of approximately 1 200 Hz.
The vibration frequency changes when the tuning fork is cov-
ered by the medium. This change is detected by the integrated
oscillator and converted into a switching command. The inte-
grated electronics evaluate the level signal and output a switch-
ing signal, directly operating connected devices.
• Key Applications: For use in liquids and slurries, for level Ensure cable gland
measurement, overfill, and dry run protection NOTE: faces downward to
Welded socket for flush mount optional avoid water ingress.

SITRANS LVL200 installation, dimensions in mm (inch)

4/88 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Technical specifications
Mode of operation Degree of protection Type 4X/NEMA 4X/IP66/IP67
Measuring principle Vibrating point level switch Conduit entry • 1 x M20x1.5 (cable: ø5 ... 9 mm),
1 x blind stopper M20x1.5; attached
Input 1 x M20x1.5 cable entry
• 1 x ½" NPT cable entry,
Measured variable High and low and demand 1 x blind stopper ½" NPT,
(via mode switch) 1 x ½" NPT cable entry
Output • 1x M12x1; 1 x blind stopper
M20x1.5
Output options • Relay output (DPDT), Weight
2 floating SPDTs
• Contactless electronic switch • Device weight Approx. 0.8 ... 4 kg
• 2 wire Namur signal output (dependent on process fitting) (0.18 ... 8.82 lb)
• Tube extension Approx 920 g/m
Measuring Accuracy (extended version) (10 oz/ft)
Repeatability 0.1 mm (0.004 inch)
Power supply
Hysteresis Approx. 2 mm (0.08 inch)
with vertical installation Supply voltage
Switching delay Approx. 500 ms (on/off) • Relay DPDT 20 ... 253 V AC, 50/60 Hz,
Frequency
Rated operating conditions
Approx. 1 200 Hz
• Contactless
20 ... 72 V DC [at U>60 V DC
20 ... 253 V AC, 50/60 Hz, 4
20 ... 253 V DC
Installation conditions • 2 wire NAMUR
• Location Indoor/outdoor Operating voltage (characteristics IEC 60947-5-6, approx. 8.2 V
Ambient conditions according to standard) for connection Off-load voltage Uo approx. 8.2 V
to an amplifier according to NAMUR Short-circuit current IU
• Ambient temperature -40 ... +70 °C (-40 ... +158 °F)
approx. 8.2 mA
• Installation category III
• Pollution degree 2 Power consumption 1 ... 8 VA (AC), approx. 1.3 W (DC)
• Relay DPDT 1 ... 8 VA (AC), approx. 1.3 W (DC)
Medium conditions
• Contactless Domestic current requirement
• Temperature approx. 3 mA (via load circuit)
- LVL200S Standard -50 ... +150 °C (-58 ... +302 °F)
Load current
- LVL200S High temperature option -50 ... +250 °C (-58 ... +482 °F) - Min. 10 mA
- LVL200E Standard: with -50 ... +150 °C (-58 ... +302 °F) - Max. 400 mA [with I > 300 mA
316L/Hastelloy the ambient temperature can
- LVL200E High temperature option: -50 ... +250 °C (-58 ... +482 °F) be max. 60 °C (140 °F)]
with 316L/Hastelloy - Max. 4 A up to 40 ms
• Pressure (vessel) -1 ... 64 bar g (-14.5 ... 928 psi g) (not WHG specified)
• Density 0.7 ... 2.5 g/cm³ (0.025 ... 0.09 lb/in³); • 2 wire Namur Current consumption
0.5 ... 2.5 g/cm³ (0.018 ... 0.09 lb/in³) - Falling characteristics  2.6 mA
by switching over uncovered/ 0.6 mA covered
-  0.6 mA uncovered/ 2.6 mA
Design covered
Material - Failure message  0.6 mA
• Enclosure Aluminum die-cast AISi10Mg, Certificates and approvals • CE, CSA
powder-coated, basis: Polyester • Overfill Protection WHG
Stainless steel housing, electro- and VLAREM II
polished 316L • FM (Non-Incendive) Class I, Div. 2,
• Tuning fork 316L (1.4404 or 1.4435), Hastelloy Groups A, B, C, D
• FM (Explosion-Proof) Class I, Div. 1,
• Extension tube [ø 21.3 mm 316L (1.4404 or 1.4435), Hastelloy
Groups A, B, C, D; (Dust Ignition-
(0.839 inch)]
Proof) Class II, III, Div. 1,
• Process connection: threaded 316L (1.4404 or 1.4435), Hastelloy Groups E, F, G1)
• Process connection: flange 316L (1.4404 or 1.4435), 316L with • IECEx d IIC T6...T2 Ga/Gb EHEDG
Hastelloy, ECTFE, or PFA coating • ATEX II 1/2G, 2G EEx d IIC T6
• Process seal Klingersil C-4400 • ATEX II 1G, 1/2G, 2G EEx ia IIC T6
Process connection Shipping approvals
• BR-Ex d IIC T6...T2
• Pipe thread, cylindrical (ISO 228 T1) G ¾" A, G 1" A • FDA, 3A, Ehedge
• Pipe thread, tapered ¾" NPT, 1" NPT, 1½" NPT • SIL/IEC61508 Declaration of Con-
• Flanges DIN from DN25, ANSI from 1" formity [SIL-2 (min/max detection)]
• Hygienic fittings Bolting DN 40 PN 40, 1, 1½, 2,
2½" Tri-Clamp PN 10, conus
DN 25 PN 40, Tuchenhagen Varivent
DN 50 PN 10, SMS

Siemens FI 01 · 2015 4/89


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Standard 7ML5746- SITRANS LVL200, Standard 7ML5746-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
tion in liquid and slurry applications such as over- tion in liquid and slurry applications such as over-
flow, high, low, and demand applications, as well as flow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous pump protection. For use in SIL-2 and hazardous
applications. applications.
Click on the Article No. for the online configura- Thread M27x1.5, PN 64/316L ¢ A30
tion in the PIA Life Cycle Portal. Conus DN 25, PN 40/316L Ra < 0.3 µm ¢ A31
Electronics Conus DN 25, PN 40/316L Ra < 0.8 µm ¢ A32
Contactless electronic switch 20...250 V AC/DC ¢ 1 Conus DN 25, PN 40/ECTFE (ZB3033)5) A33
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC ¢ 2 Conus M52, PN 40/316L ¢ A34
NAMUR signal1) ¢ 4 Conus M52, PN 40/316L Ra < 0.3 µm ¢ A35
Approvals Conus M52, PN 40/316L Ra < 0.8 µm ¢ A36
Without approvals ¢ A Tri-Clamp 1", PN 16/316L Ra < 0.3 µm ¢ A37
Overfill protection (WHG) ¢ B
Tri-Clamp 1", PN 16/Hastelloy ¢ A38
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG 2) ¢ C
Tri-Clamp 1", PN 16/316L Ra < 0.8 µm ¢ A40

4
3)
ATEX II 1/2G, 2G EEx d IIC T6 + WHG ¢ D Tri-Clamp 1½", PN 16/316L Ra < 0.3 µm ¢ A4 1
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping ¢ E
approvals2) Tri-Clamp 1½", PN 16/Hastelloy ¢ A42
ATEX II 1/2G, 2G EEx d IIC T6 + shipping ¢ F Tri-Clamp 1½", PN 16/316L Ra < 0.8 µm ¢ A43
approvals3) Tri-Clamp 2", PN 16/316L Ra < 0.3 µm ¢ A44
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2 D ¢ G Tri-Clamp 2", PN 16/Hastelloy ¢ A45
IP6X T2)
Tri-Clamp 2", PN 16/316L Ra < 0.8 µm ¢ A46
IECEx Ex ia IIC T62) ¢ H
Tri-Clamp 2½", PN 10/316L Ra < 0.3 µm ¢ A47
Shipping approvals ¢ K
Tri-Clamp 2½", PN 10/316L Ra < 0.8 µm ¢ A48
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, ¢ N
G 2)4) Tri-Clamp 3", PN 10/316L Ra < 0.3 µm ¢ A50
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) ¢ P Tri-Clamp 3", PN 10/316L Ra < 0.8 µm ¢ A51
Class II, III, Div. 1, Groups E, F, G3)4) Bolting DN 32, PN 40 DIN11851/316L Ra < 0.3 µm ¢ A52
FM (NI) Class I, Div. 2, Groups A, B, C, D4) ¢ Q Bolting DN 32, PN 40 DIN11851/316L Ra < 0.8 µm ¢ A53
Bolting DN 25, PN 40 DIN11851/316L Ra < 0.3 µm ¢ A54
IECEx d IIC T6...T2 Ga/Gb ¢ R
Bolting DN 25, PN 40 DIN11851/316L Ra < 0.8 µm ¢ A55
CSA(XP)CL I, II, III Div. 1,Groups A,,B, C, D, E, F, G ¢ S
CSA(NI)CL I, II, III, Div. 2, Groups A, B, C, D, E, F, G¢ T Bolting DN 40, PN 40 DIN11851/316L Ra < 0.3 µm ¢ A56
Bolting DN 40, PN 40 DIN11851/316L Ra < 0.8 µm ¢ A57
BR-Ex d IIC T6...T2 ¢ U
Bolting DN 40, PN 40 DIN11864-1 A/316L ¢ A58
CSA(IS)CL I, II, III Div. 1, Groups A, B, C, D, E, F, G ¢ V Ra < 0.8 µm ZB3052
Process connection Bolting DN 50, PN 25 DIN11851/316L Ra < 0.3 µm ¢ A60
Thread G¾" A, PN 64/316L ¢ A00 Bolting DN 50, PN 25 DIN11851/316L Ra < 0.8 µm ¢ A61
Thread G¾" A, PN 64/316L Ra < 0.8 µm ¢ A01 Bolting DN 50, PN 25 DIN11864-1 A/316L ¢ A62
Thread ¾" NPT, PN 64/316L ¢ A02 Ra < 0.8 µm ZB3052
¢ A03
Thread ¾" NPT, PN 64/316L Ra < 0.8 µm Hygienic w. compr. nut F40, PN 25/316L ¢ A63
Thread ¾" NPT, PN 64/Monel A04 Hygienic w. compr. nut F40, PN 25/316L ¢ A64
Thread G¾" A, PN 64/Hastelloy ¢ A05 Ra < 0.3 µm ¢
Hygienic w. compr. nut F40, PN 25/316L ¢ A65
Thread ¾" NPT, PN 64/Hastelloy ¢ A06 Ra < 0.8 µm
Thread G1" A, PN 64/316L ¢ A07
Thread G1" A, PN 64/316L ECTFE coated A08 Varivent N50-40/316L Ra < 0.3 µm ¢ A66
MB19825) Varivent N50-40/316L Ra < 0.8 µm ¢ A67
Varivent N125/100/316L Ra < 0.8 µm ¢ A68
Thread G1" A, PN 64/316L PFA coated5) A10
Thread G1" A, PN 64/Monel ¢ A11 DRD flange, PN 40/316L ZB3007 ¢ A70
Thread G1" A, PN 64 / 316L Ra<0.8µm ¢ A12 SMS DN 38/316L Ra < 0.8 µm5) ¢ A71
Thread G1" A, PN 64/316L Ra < 0.8 µm ¢ A13 SMS DN 51, PN 6/316L Ra < 0.8 µm5) ¢ A72
Thread 1" NPT, PN 64/316L5) A14 Swagelok VCR screwing ZG2579, PN 64/316L A73
Thread 1" NPT, PN 64/316L ECTFE A15 Neumo biocontrol size 25, PN 16/316L Ra < 0.8 µm A74
coatedMB19825) Neumo biocontrol size 50, PN 16/316L Ra < 0.8 µm5) A75
Thread 1" NPT, PN 64/316L PFA-coated A16
Neumo biocontrol size 65, PN 16/316L Ra < 0.8 µm A76
Thread 1" NPT, PN 64/Monel ¢ A17 Neumo biocontrol size 80, PN 16/316L Ra < 0.8 µm A77
Thread 1" NPT, PN 64/316L Ra < 0.8 µm ¢ A18 SÜDMO DN 50, PN 10/316L Ra<0,8µm A78
Thread G1" A, PN 64/Hastelloy ¢ A20 Small flange DN 25, PN 1.5 DIN 28403/316L pol. A80
Thread G1½" A, PN 64/316L ¢ A21 Ra < 0.8 µm
Thread G1½" A, PN 64/316L Ra<0,8µm ¢ A22 Small flange DN 40, PN 1.5 DIN 28403/316L pol. A81
Ra < 0.8 µm
Thread G1½" A, PN 64/Hastelloy ¢ A23 Ingold connection, PN 16/316L Ra < 0.8 µm A82
Thread 1" NPT, PN 64/Hastelloy ¢ A24
Thread 1½" NPT, PN 64/316L ¢ A25 Ingold connection, PN 16/Hastelloy A83
Terminal DN 33.7 PN 40 DIN11864-3-A-/316L BN2 A84
Thread 1½" NPT, PN 64/316L Ra<0,8µm ¢ A26 Ra < 0.8 µm5)
Thread 1½" NPT, PN 64/Hastelloy ¢ A27 Hygienic fl. DN 50 PN 16 DIN11864-2-A-/316L A85
Thread G2" A, PN 64/316L ¢ A28 Ra < 0.8 µm

4/90 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Standard 7ML5746- SITRANS LVL200, Standard 7ML5746-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
tion in liquid and slurry applications such as over- tion in liquid and slurry applications such as over-
flow, high, low, and demand applications, as well as flow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous pump protection. For use in SIL-2 and hazardous
applications. applications.
Flange DN 25, PN 6 Form C, DIN 2501/316L A86 Flange DN 80, PN 40 Form C, DIN 2501/PFA5) B56
Flange DN 25, PN 6 Form C, DIN 2501/PFA5) A87 Flange DN 80, PN 40 Form C, DIN 2501/ B57
Flange DN 25, PN 40 Form C, DIN 2501/316L A88 Enamelled6)
Flange DN 80, PN 40 Form F, DIN 2501/316L B58
Flange DN 25, PN 40 Form C, DIN 2501/Hastelloy B00
Flange DN 25, PN 40 Form C, DIN 2501/ECTFE5) B01 Flange DN 80, PN 40 Form N, DIN 2501/316L B60
Flange DN 25, PN 40 Form C, DIN 2501/PFA5) B02 Flange DN 100, PN 16 Form C, DIN 2501/316L B62
Flange DN 100, PN 16 Form C, DIN 2501/Hastelloy B63
Flange DN 25, PN 40 Form C, DIN 2501/Enamelled B03
Flange DN 25, PN 40 Form D, DIN 2501/316L B04 Flange DN 100, PN 16 Form C, DIN 2501/ECTFE5) B64
Flange DN 25, PN 40 Form F, DIN 2501/316L B05 Flange DN 100, PN 16 Form C, DIN 2501/PFA5) B65
Flange DN 100, PN 16 Form C, DIN 2501/ B66
Flange DN 25, PN 40 Form N, DIN 2501/316L B06
Enamelled6)
Flange DN 25, PN 40 Form N, DIN 2501/Hastelloy
Flange DN 25, PN 40 Form N, DIN 2501/Monel
B07
B08 Flange DN 100, PN 16 Form D, DIN 2501/316L B67 4
solid Flange DN 100, PN 16 Form F, DIN 2501/316L B68
Flange DN 25, PN 40 V13, DIN 2501/316L B10 Flange DN 100, PN 16 Form N, DIN 2501/316L B70
Flange DN 32, PN 40 Form C, DIN 2501/316L B11 Flange DN 100, PN 40 Form C, DIN 2501/316L B71
Flange DN 32, PN 40 Form C, DIN 2501/ECTFE5) B12 Flange DN 100, PN 40 Form C, DIN 2501/ECTFE5) B72
Flange DN 40, PN 6 Form C, DIN 2501/316L B13 Flange DN 100, PN 40 Form C, DIN 2501/PFA5) B73
Flange DN 40, PN 6 Form C, DIN 2501/ECTFE5) B14 Flange DN 100, PN 40 Form C, DIN 2501/ B74
Flange DN 40, PN 40 Form C, DIN 2501/316L B15 Enamelled6)
Flange DN 40, PN 40 Form C, DIN 2501/Hastelloy B16 Flange DN 100, PN 40 Form F, DIN 2501/316L B75
Flange DN 40, PN 40 Form C, DIN 2501/ECTFE5) B17 Flange DN 100, PN 40 Form N, DIN 2501/316L B76
Flange DN 40, PN 40 Form C, DIN 2501/PFA5) B18 Flange DN 100, PN 40 V13, DIN 2501/316L B77
Flange DN 40, PN 40 Form C, DIN 2501/ B20 Flange DN 100, PN 64 Form E, DIN 2501/316L B78
Enamelled6) Flange DN 100, PN 100 Form E, DIN 2501/316L B80
Flange DN 40, PN 40 Form F, DIN 2501/316L B21 Flange DN 100, PN 100 Form L, DIN 2501/316L B81
Flange DN 40, PN 40 Form N, DIN 2501/316L B22 Flange DN 125, PN 16 Form F, DIN 2501/316L B82
Flange DN 40, PN 40 Form E, DIN 2501/316L B23 Flange DN 125, PN 40 Form C, DIN 2501/316L B83
Flange DN 40, PN 40 V13, DIN 2501/316L B24 Flange DN 125, PN 40 Form N, DIN 2512/ 316L B84
Flange DN 50, PN 40 Form C, DIN 2501/316L B25 Flange DN 150, PN 16 Form C, DIN 2501/316L B85
Flange DN 50, PN 40 Form C, DIN 2501/Hastelloy B26 Flange DN 150, PN 16 Form C, DIN 2501/Hastelloy B86
Flange DN 50, PN 40 Form C, DIN 2501/ECTFE5) B27 Flange DN 150, PN 16 Form C, DIN 2501/ECTFE5) B87
Flange DN 50, PN 40 Form C, DIN 2501/ B28 Flange DN 150, PN 16 Form C, DIN 2501/PFA5) B88
ECTFE (ZB3108)5) Flange DN 150, PN 16 Form D, DIN 2501/316L C00
Flange DN 50, PN 40 Form C, DIN 2501/PFA5) B30 Flange DN 150, PN 40 Form C, DIN 2501/316L C01
Flange DN 50, PN 40 Form D, DIN 2501/316L B31 Flange DN 150, PN 40 Form C, DIN 2501/Hastelloy C02
Flange DN 50, PN 40 Form D, DIN 2501/Hastelloy B32 Flange DN 150, PN 40 Form F, DIN 2501/316L C03
Flange DN 50, PN 40 Form F, DIN 2501/316L B33 Flange DN 150, PN 40 Form N, DIN 2512/316L C04
Flange DN 50, PN 40 Form N, DIN 2501/316L B34 Flange DN 200, PN 10 Form C, DIN 2501/ECTFE5) C05
Flange DN 50, PN 40 Form N, DIN 2501/Hastelloy B35 Flange DN 200, PN 16 Form C, DIN 2501/316L C06
Flange DN 50, PN 40 Form E, DIN 2501/316L B36 Flange DN 25, PN 40 Form B1, EN 1092-1/316L C07
Flange DN 50, PN 40 V13, DIN 2501/316L B37 Flange DN 25, PN 40 Form B1, EN 1092-1/Hastelloy C08
Flange DN 50, PN 40 R13, DIN 2501/316L B38 Flange DN 25, PN 40 Form B1, EN/ 316L/ PFA5) C10
Flange DN 50, PN 64 Form F, DIN 2501/316L B40 Flange DN 25, PN 40 Form B1, EN 1092-1/ C11
Flange DN 50, PN 64 Form N, DIN 2501/Hastelloy B41 Enamelled 6)
Flange DN 50, PN 64 Form C, DIN 2501/316L B42 Flange DN 25, PN 40 Form B2, EN 1092-1/316L C12
Flange DN 50, PN 64 Form L, DIN 2501/316L B43 Flange DN 25, PN 40 Form F, EN 1092-1/316L C13
Flange DN 50, PN 100 Form E, DIN 2501/316L B44 Flange DN 25, PN 63 Form B1, EN 1092-1/316L C14
Flange DN 50, PN 100 Form L, DIN 2501/316L B45 Flange DN 25, PN 100 Form B2, EN 1092-1/316L C15
Flange DN 40, PN 40 Form B1, EN/ 316L C16
Flange DN 65, PN 40 Form C, DIN 2501/316L B46
Flange DN 40, PN 40 Form B1, EN 1092-1/PFA5) C17
Flange DN 65, PN 40 Form C, DIN 2501/Hastelloy B47
Flange DN 65, PN 40 Form C, DIN 2501/ECTFE5) B48 Flange DN 40, PN 40 Form B2, EN/316L C18
Flange DN 50, PN 40 Form B1, EN/316L C20
Flange DN 65, PN 40 Form C, DIN 2501/PFA5) B50 Flange DN 50, PN 40 Form B1, EN 1092-1/ C21
Flange DN 65, PN 40 Form F, DIN 2501/316L B51 Hastelloy
Flange DN 65, PN 64 Form E, DIN 2501/316L B52
Flange DN 50, PN 40 Form B1, EN 1092-1/ C22
Flange DN 80, PN 40 Form C, DIN 2501/316L B53 Monel ZB2977
Flange DN 80, PN 40 Form C, DIN 2501/ Hastelloy B54 Flange DN 50, PN 40 Form B1, EN 1092-1/ECTFE5) C23
Flange DN 80, PN 40 Form C, DIN 2501/ECTFE5) B55 Flange DN 50, PN 40 Form B1, EN/ 316L/PFA5) C24

Siemens FI 01 · 2015 4/91


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Standard 7ML5746- SITRANS LVL200, Standard 7ML5746-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
tion in liquid and slurry applications such as over- tion in liquid and slurry applications such as over-
flow, high, low, and demand applications, as well as flow, high, low, and demand applications, as well as
pump protection. For use in SIL-2 and hazardous pump protection. For use in SIL-2 and hazardous
applications. applications.
Flange DN 50, PN 40 Form B1, EN 1092-1/ C25 Flange 2" 300 lb RF, ANSI B16.5/316L C82
Enamelled6) Flange 2" 300 lb RF, ANSI B16.5/Hastelloy C83
Flange DN 50, PN 40 Form C, EN 1092-1/316L C26
Flange 2" 300 lb RF, ANSI B16.5/ECTFE5) C85
Flange DN 50, PN 40 Form D, EN/316L C27
Flange 2" 300 lb RF, ANSI B16.5/PFA5) C86
Flange DN 50, PN 40 Form D, EN 1092-1/Hastelloy C28 Flange 2" 300 lb RF, ANSI B16.5 Enamelled6) C87
Flange DN 50, PN 40 Form B2, EN 1092-1/316L C30
Flange 2" 300 lb RJF, ANSI B16.5/316L C88
Flange DN 50, PN 40 Form E, EN 1092-1/316L C31
Flange 2" 300 lb ST, ANSI B16.5/316L D00
Flange DN 80, PN 40 Form B1, EN 1092-1/316L C32 Flange 2" 300 lb LG (large groove), D01
Flange DN 80, PN 40 Form B1, EN 1092-1/Hastelloy C33 ANSI B16.5/316L
Flange DN 80, PN 40 Form B1, EN 1092-1/ECTFE5) C34 Flange 2" 300 lb LT, ANSI B16.5/316L D02

4 Flange DN 80, PN 40 Form B1, EN 1092-1/


Enamelled6)
C35 Flange 2" 600 lb RF, ANSI B16.5/316L
Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977
D03
D04
Flange DN 80, PN 40 Form B2, EN 1092-1/316L C36
Flange 2" 600 lb RF, ANSI B16.5/ECTFE5) D05
Flange DN 100, PN 16 Form B1, EN 1092-1/316L C37
Flange 2" 600 lb RJF, ANSI B16.5/316L D06
Flange DN 100, PN 16 Form B1, EN 1092-1/ C38 Flange 2" 600 lb LG, ANSI B16.5/316L D07
Hastelloy
Flange 2" 900 lb RJF, ANSI B16.5/316L D08
Flange DN 100, PN 16 Form B1, EN 1092-1/ C40 Flange 2½" 150 lb RF, ANSI B16.5/316L D10
Enamelled6)
Flange 2½" 300 lb RF, ANSI B16.5/316L D11
Flange DN 100, PN 40 Form B1, EN 1092-1/316L C41
Flange DN 100, PN 40 Form B1, EN 1092-1/ C42 Flange 3" 150 lb RF, ANSI B16.5/316L D12
Enamelled6) Flange 3" 150 lb RF, ANSI B16.5/Hastelloy D13
Flange 3" 150 lb RF, ANSI B16.5/ECTFE5) D14
Flange DN 100, PN 40 Form C, EN 1092-1/316L C43
Flange DN 100, PN 63 Form B2, EN 1092-1/316L C44 Flange 3" 150 lb RF, ANSI B16.5/PFA5) D15
Flange DN 150, PN 16 Form B1, EN 1092-1/316L C45 Flange 3" 150 lb RF, ANSI B16.5/Enamelled6) D16
Flange 3" 150 lb FF, ANSI B16.5/316L D17
Flange DN 150, PN 16 Form B1, EN 1092-1/PFA5) C46
Flange DN 150, PN 40 Form B1, EN 1092-1/316L C47 Flange 3" 150 lb FF, ANSI B16.5/ECTFE5) D18
Flange 3" 150 lb FF, ANSI B16.5/PFA5) D20
Flange DN 150, PN 40 Form B1, EN 1092-1/ C48
ECTFE5) Flange 3" 300 lb RF, ANSI B16.5/316L D21
Flange DN 150, PN 40 Form B2, EN 1092-1/316L C50 Flange 3" 300 lb RF, ANSI B16.5/Hastelloy D22
Flange 1" 150 lb ANSI B16.5/316L C51 Flange 3" 300 lb RF, ANSI B16.5/ECTFE5) D23
Flange 1" 150 lb RF, ANSI B16.5/Hastelloy C52 Flange 3" 300 lb RF, ANSI B16.5/PFA5) D24
Flange 1" 150 lb RF, ANSI B16.5/Monel ZB2977 C53 Flange 3" 300 lb RF, ANSI B16.5/Enamelled6) D25
Flange 1" 150 lb RF, ANSI B16.5/ECTFE5) C54 Flange 3" 600 lb RF, ANSI B16.5/316L D26
Flange 1" 150 lb RF, ANSI B16.5/PFA5) C55 Flange 3½" 150 lb RF, ANSI B16.5/316L D27
Flange 1" 150 lb RF, ANSI B16.5/Enamelled6) C56 Flange 3½" 150 lb RF, ANSI B16.5/ECTFE5) D28
Flange 1" 300 lb RF, ANSI B16.5/316L C57 Flange 4" 150 lb RF, ANSI B16.5/316L D30
Flange 1" 300 lb RF, ANSI B16.5/ECTFE5) C58 Flange 4" 150 lb RF, ANSI B16.5/Hastelloy D31
Flange 1" 600 lb RF, ANSI B16.5/316L C60 Flange 4" 150 lb RF, ANSI B16.5/ECTFE5) D32
Flange 1½" 150 lb RF, ANSI B16.5/316L C61 Flange 4" 150 lb RF, ANSI B16.5/PFA5) D33
Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy C62 Flange 4" 150 lb RF, ANSI B16.5/Enamelled6) D34
Flange 1½" 150 lb RF, ANSI B16.5/ECTFE5) C63 Flange 4" 150 lb LT, ANSI B16.5/316L D35
Flange 1½" 150 lb RF, ANSI B16.5/PFA5) C64 Flange 4" 300 lb RF, ANSI B16.5/316L D36
Flange 1½" 150 lb RF, ANSI B16.5 Enamelled6) C65 Flange 4" 300 lb RF, ANSI B16.5/Hastelloy D37
Flange 1½" 150 lb FF, ANSI B16.5/ECTFE5) C66 Flange 4" 300 lb RF, ANSI B16.5/ECTFE5) D38
Flange 1½" 300 lb RF, ANSI B16.5/316L C67 Flange 4" 300 lb RJF, ANSI B16.5/316L D40
Flange 1½" 300 lb RF, ANSI B16.5/Monel ZB2977 C68 Flange 4" 300 lb LG, ANSI B16.5/316L D41
Flange 1½" 300 lb RF, ANSI B16.5/ECTFE6) C70 Flange 4" 300 lb LT, ANSI B16.5/316L D42
Flange 1½" 600 lb RF, ANSI B16.5/316L C71 Flange 4" 600 lb RF, ANSI B16.5/316L D43
Flange 2" 150 lb RF, ANSI B16.5/316L C72 Flange 4" 600 lb RJF, ANSI B16.5/316L D44
Flange 2" 150 lb RF, ANSI B16.5/Hastelloy C73 Flange 6" 150 lb RF, ANSI B16.5/316L D45
Flange 2" 150 lb RF, ANSI B16.5/Monel ZB2977 C74 Flange 6" 150 lb RF, ANSI B16.5/Hastelloy D46
Flange 2" 150 lb RF, ANSI B16.5/ECTFE5) C75 Flange 6" 150 lb RF, ANSI B16.5/ECTFE5) D47
Flange 2" 150 lb RF, ANSI B16.5/PFA5) C76 Flange 6" 150 lb RF, ANSI B16.5/PFA5) D48
Flange 2" 150 lb RF, ANSI B16.5/Enamelled6) C77 Flange 6" 150 lb RJF, ANSI B16.5/316L D50
Flange 2" 150 lb FF, ANSI B16.5/316L C78 Flange 6" 300 lb RF, ANSI B16.5/316L D51
Flange 2" 150 lb FF, ANSI B16.5/ECTF5) C80 Flange 8" 150 lb RF, ANSI B16.5/316L D52
Flange 2" 150 lb SG (small groove), C81 Flange 8" 150 lb RF, ANSI B16.5/ECTFE5) D53
ANSI B16.5/316L Flange 1" BS.10 Table E/316L D54

4/92 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LVL200, Standard 7ML5746- Functional Safety (SIL 2). Device suitable for use in C20
Compact vibrating level switch for material detec-
7 7 7 77 - 77 A 0 accordance with IEC 61508 and IEC 615111)
tion in liquid and slurry applications such as over-
flow, high, low, and demand applications, as well as Dye penetration test + 3.1 certificate/instrument1) C13
pump protection. For use in SIL-2 and hazardous
applications. X-ray test + 3.1 certificate/instrument1) C14

Flange 1" BS.10 Table E/PFA5) D55 Positive material identification test C16
+ 3.1 certificate/instrument1)
Flange 1½" BS.10 Table E/316L D56
Flange 3½" BS.10 Table E/316L D57 Roughness test + 3.1 certificate/instrument1) C18
Flange 4" BS.10 Table E/ECTFE5) D58 Pressure test + 3.1 certificate/instrument1) C31
Flange DN 40 10K, JIS/316L D60 Helium leak test + 3.1 certificate/instrument1) C32
Flange DN 50 10K, JIS/316L D61
Ferrite measuring accuracy to DIN32514-1 C60
Flange DN 80 10K, JIS/316L D62 + 3.1 certificate/instrument1)
Flange DN 100 10K, JIS/316L D63
Pressure test according to Norsok C61
Adapter/Process temperature + 3.1 certificate/instrument1)
Without adapter/-50 ... +150 °C (-58 ... +302 °F) ¢ 1

4
Additional Operating Instructions Article No.
With adapter/-50 ... +200 °C (-58 ... +392 °F)7) ¢ 2
With adapter/-50 .... +250 °C (-58 ... +482 °F) ¢ 3 LVL200 (DPDT Relay)
With gas-tight leadthrough/-50 ... +150 °C ¢ 4 • English 7ML1998-5KR01
(-58 ... +302 °F)
• French 7ML1998-5KR11
With gas-tight leadthrough/-50 ... +250 °C ¢ 5
(-58 ... +482 °F) • Spanish 7ML1998-5KR21
Housing/ Cable entry • German 7ML1998-5KR31
Aluminium IP66/IP67/M20x1.5 ¢ A LVL200 (Contactless electronic switch)
Aluminium IP66/IP67/½" NPT ¢ B
316L stainless steel (electropolished) C • English 7ML1998-5KQ01
IP66/IP67/M20X1.58)9) • French 7ML1998-5KQ11
316L stainless steel (electropolished) D
IP66/IP67/½" NPT8)9) • Spanish 7ML1998-5KQ21
1) • German 7ML1998-5KQ31
Available with Adapter/Process temperature options 1, 3, 4, and 5 only
2)
Available with Electronics option 4 only Electronics module LVL200 Relay
3) • English 7ML1998-5LS01
Available with Adapter/Process temperature options 1 and 3 only
4)
Available with Housing/Cable entry option B only • French 7ML1998-5LS11
5)
Available with Adapter/Process temperature options 1 and 4 only
6)
• Spanish 7ML1998-5LS21
Available with Adapter/Process temperature options 1, 2, and 4 only
7) • German 7ML1998-5LS31
Available with enamelled Process connection options only
This device is shipped with the Siemens Milltronics
8) Available with Approval options A, B, C only manual DVD containing the Operating Instructions
9) Not available with SIL/IEC61508 Certificate of conformity library.
(SIL-2 min. and max. detection)
Spare Parts and Accessories
¢ We can offer shorter delivery times for configurations designated with the Electronics module SITRANS LVL200 Relay 7ML1830-1NC
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Electronics module SITRANS LVL200 Contactless 7ML1930-6AA
LVL200 Threaded Welded Socket
Selection and Ordering data Order code
• G¾" A/316L with FKM Seal 7ML1930-1EE
Further designs
• G1" A/316L with FKM Seal 7ML1930-1EF
Please add "-Z" to Article No. and specify Order
code(s). • M27x1.5/316L with FKM Seal 7ML1930-1EG
Cleaning including Certificate W01 • G¾" A/316L with EPDM Seal 7ML1930-1EH
(oil, grease, and silicone free) • G1" A/316L with EPDM Seal 7ML1930-1EJ
Identification Label (measurement loop) stainless Y17 • M27x1.5/316L with EPDM Seal 7ML1930-1EK
steel:
max. 16 characters add in plain text 1) Listed Certificates are not available with all configurations, please contact
Identification Label (measurement loop) Foil: Y18 factory for more information
max. 16 characters add in plain text
Acceptance test certificate 3.1 NACE MR 0775 for D07
material EN102041)
Acceptance test certificate 3.1 for instrument C12
EN102041)
Acceptance test Certificate 2.2 for material C15
EN102041)

Siemens FI 01 · 2015 4/93


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Rigid extension 7ML5747- SITRANS LVL200, Rigid extension 7ML5747-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
77 7 77 - 77 77 7 7 7 77 - 77 7 7
tion in liquid applications such as overflow, high, tion in liquid applications such as overflow, high,
low, and demand applications, as well as pump low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applica- protection. For use in SIL-2 and hazardous applica-
tions. tions.
Click on the Article No. for the online configura- Cyl. socket/316Ti/1.4581 ECTFE coated ZB29846) A31
tion in the PIA Life Cycle Portal. Conus DN 25 PN 40/316L Ra < 0.3 µm A32
Electronics Conus DN 25 PN 40/316L Ra < 0.8 µm. A33
Contactless electronic switch 20...250 V AC/DC 1 Conus DN 25 PN 40/ECTFE (ZB3033)6) A34
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC 2 Conus M52 PN 40/316L A35
NAMUR signal1) 4 Conus M52 PN 40/316L Ra < 0.3 µm A36
Approvals Conus M52 PN 40/316L Ra < 0.8 µm A37
Without approvals A Tri-Clamp 1" PN 16/316L Ra < 0.3 µm A38
Overfill protection (WHG) B Tri-Clamp 1" PN 16/Hastelloy A40
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG2) C Tri-Clamp 1" PN 16/316L Ra < 0.8 µm A41
4 ATEX II 1/2G, 2G EEx d IIC T6 + WHG3)4)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping
D
E
Tri-Clamp 1½" PN 16/316L Ra < 0.3 µm
Tri-Clamp 1½" PN 16/Hastelloy
A42
A43
approvals2) Tri-Clamp 1½" PN 16/316L Ra < 0.8 µm A44
ATEX II 1/2G, 2G EEx d IIC T6 + shipping F Tri-Clamp 2" PN 16/316L Ra < 0.3 µm A45
approvals3)4) Tri-Clamp 2" PN 16/Hastelloy A46
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2D G Tri-Clamp 2" PN 16/316L Ra < 0.8 µm A47
IP6X T2)
Tri-Clamp 2½" PN 10/316L Ra < 0.3 µm A48
IECEx Ex ia IIC T62) H
Tri-Clamp 2½" PN 10/316L Ra < 0.8 µm A50
Shipping approvals K
Tri-Clamp 3" PN 10/316L Ra < 0.3 µm A51
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 2)5) N
Tri-Clamp 3" PN 10/316L Ra < 0.8 µm A52
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) P
Class II, III, Div. 1, Groups E, F, G3)4)5) Bolting DN 32 PN 40 DIN11851/316L Ra < 0.3 µm A53

FM (NI) Class I, Div. 2, Groups A, B, C, D5) Q Bolting DN 32 PN 40 DIN11851/316L Ra < 0.8 µm A54
IECEx d IIC T6...T2 Ga/Gb4) R Bolting DN 25 PN 40 DIN11851/316L Ra < 0.3 µm A55
CSA(XP)CL I,II,III Div. 1,Groups A, B, C, D, E, F, S Bolting DN 25 PN 40 DIN11851/316L Ra < 0.8 µm A56
G...T2 4) Ga/Gb Bolting DN 40 PN 40 DIN11851/316L Ra < 0.3 µm A57
CSA(NI)CL I,II,III, Div. 2,Groups A, B, C, D, E, F, G T Bolting DN 40 PN 40 DIN11851/316L Ra < 0.8 µm A58
BR-Ex d IIC T6...T2 U Bolting DN 40 PN 40 DIN11864-1 A/316L A60
CSA(IS)CL I, II, III Div. 1, Groups A, B, C, D, E, F, G V Ra < 0.8 µm ZB3052

Process connection Bolting DN 50 PN 25 DIN11851/316L Ra < 0.3 µm A61


Bolting DN 50 PN 25 DIN11851/316L Ra < 0.8 µm A62
Thread G¾" A, PN 64/316L A00 Bolting DN 50 PN 25 DIN11864-1 A/316L A63
Thread G¾" A, PN 64/316L Ra < 0.8 µm A01 Ra < 0.8 µm ZB3052
Thread ¾" NPT, PN 64/316L A02
Hygienic w.compr.nut F40 PN 25/316L A64
Thread ¾" NPT, PN 64/316L Ra < 0.8 µm A03 Hygienic w.compr.nut F40 PN 25/316L Ra < 0.3 µm A65
Thread ¾" NPT, PN 64/Monel A04 Hygienic w.compr.nut F40 PN 25/316L Ra < 0.8 µm A66
Thread G¾" A, PN 64/Hastelloy A05
Varivent N50-40/316L Ra < 0.3 µm A67
Thread ¾" NPT, PN 64/Hastelloy A06 Varivent N50-40/316L Ra < 0.8 µm A68
Thread G1" A, PN 64/316L A07 Varivent N125/100/316L Ra < 0.8 µm A70
Thread G1" A, PN 64/316L ECTFE coated A08
MB19826) DRD flange PN 40/316L ZB3007 A71
SMS DN 38/316L Ra < 0.8 µm6) A72
Thread G1" A, PN 64/316L PFA coated6) A10 SMS DN 51 PN 6/316L Ra < 0.8 µm6) A73
Thread G1" A, PN 64/Monel A11
Thread G1" A, PN 64/316L Ra < 0.8 µm A13 Swagelok VCR screwing ZG2579 PN 64/316L A74
Neumo biocontrol size 25 PN 16/316L Ra < 0.8 µm A75
Thread 1" NPT, PN 64/316L A14 Neumo biocontrol size 50 PN 16/316L Ra < 0.8 µm A76
Thread 1" NPT, PN 64/316L ECTFE coated MB19826) A15
Thread 1" NPT, PN 64/316L PFA coated6) A16 Neumo biocontrol size 65 PN 16/316L Ra < 0.8 µm A77
Neumo biocontrol size 80 PN 16/316L Ra < 0.8 µm A78
Thread 1" NPT, PN 64/Monel A17 SÜDMO DN 50 PN 10/316L Ra < 0.8 µm A80
Thread 1" NPT, PN 64/316L Ra < 0.8 µm A18
Thread G1" A, PN 64/Hastelloy A20 Small flange DN 25 PN 1.5 DIN 28403/316L pol. A81
Ra < 0.8 µm
Thread G1½" A, PN 64/316L A21 Small flange DN 40 PN 1.5 DIN 28403/316L pol. A82
Thread G1½" A, PN 64/316L Ra <0.8 µm A22 Ra < 0.8 µm
Thread G1½" A, PN 64/Hastelloy A23 Ingold connection PN 16/316L Ra < 0.8 µm A83
Thread 1" NPT, PN 64/Hastelloy A24 Terminal DN 33.7 PN 40 DIN 11864-3-A-/316L BN2 A84
Thread 1½" NPT, PN 64/316L A25 Ra < 0.8 µm
Thread 1½" NPT, PN 64/316L Ra< 0.8 µm A26 Hygienic fl. DN 50 PN 16 DIN 11864-2-A-/316L A85
Ra < 0.8 µm
Thread 1½" NPT, PN 64/Hastelloy A27
Flange DN 25 PN 6 Form C, DIN 2501/316L A86
Thread G2" A, PN 64/316L A28
Thread M27x1.5 PN 64/316L A30

4/94 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Rigid extension 7ML5747- SITRANS LVL200, Rigid extension 7ML5747-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
77 7 77 - 77 77 7 7 7 77 - 77 7 7
tion in liquid applications such as overflow, high, tion in liquid applications such as overflow, high,
low, and demand applications, as well as pump low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applica- protection. For use in SIL-2 and hazardous applica-
tions. tions.
Flange DN 25 PN 6 Form C, DIN 2501/PFA6) A87 Flange DN 80 PN 40 Form N, DIN 2501/316L B57
Flange DN 25 PN 40 Form C, DIN 2501/316L A88 Flange DN 80 PN 40 Form N, DIN 2501/Hastelloy B58
Flange DN 25 PN 40 Form C, DIN 2501/Hastelloy B00 Flange DN 100 PN 16 Form C, DIN 2501/316L B60
Flange DN 25 PN 40 Form C, DIN 2501/ECTFE6) B01 Flange DN 100 PN 16 Form C, DIN 2501/Hastelloy B61
Flange DN 25 PN 40 Form C, DIN 2501/PFA6) B02 Flange DN 100 PN 16 Form C, DIN 2501/ECTFE6) B62
Flange DN 25 PN 40 Form D, DIN 2501/316L B03 Flange DN 100 PN 16 Form C, DIN 2501/PFA6) B63
Flange DN 25 PN 40 Form F, DIN 2501/316L B04 Flange DN 100 PN 16 Form D, DIN 2501/316L B64
Flange DN 25 PN 40 Form N, DIN 2501/316L B05 Flange DN 100 PN 16 Form F, DIN 2501/316L B65
Flange DN 25 PN 40 Form N, DIN 2501/Hastelloy B06 Flange DN 100 PN 16 Form N, DIN 2501/316L B66
Flange DN 25 PN 40 Form N, DIN 2501/Monel solid B07 Flange DN 100 PN 40 Form C, DIN 2501/316L B67
Flange DN 25 PN 40 V13, DIN 2501/316L
Flange DN 32 PN 40 Form C, DIN 2501/316L
B08
B10
Flange DN 100 PN 40 Form C, DIN 2501/ECTFE6)
Flange DN 100 PN 40 Form C, DIN 2501/PFA6)
B68
B70
4
Flange DN 100 PN 40 Form C, DIN 2501/ B71
Flange DN 32 PN 40 Form C, DIN 2501/ECTFE6) B11 Enamelled7)
Flange DN 40 PN 6 Form C, DIN 2501/316L B12 Flange DN 100 PN 40 Form F, DIN 2501/316L B72
Flange DN 40 PN 6 Form C, DIN 2501/ECTFE6) B13 Flange DN 100 PN 40 Form N, DIN 2501/316L B73
Flange DN 40 PN 40 Form C, DIN 2501/316L B14 Flange DN 100 PN 40 V13, DIN 2501/316L B74
Flange DN 40 PN 40 Form C, DIN 2501/Hastelloy B15 Flange DN 100 PN 64 Form E, DIN 2501/316L B75
Flange DN 40 PN 40 Form C, DIN 2501/ECTFE6) B16 Flange DN 100 PN 100 Form E, DIN 2501/316L B76
Flange DN 40 PN 40 Form C, DIN 2501/PFA6) B17 Flange DN 100 PN 100 Form L, DIN 2501/316L B77
Flange DN 40 PN 40 Form C, DIN 2501/Ena- B18 Flange DN 125 PN 16 Form F, DIN 2501/316L B78
melled7) Flange DN 125 PN 40 Form C, DIN 2501/316L B80
Flange DN 40 PN 40 Form F, DIN 2501/316L B20
Flange DN 125 PN 40 Form N, DIN 2512/316L B81
Flange DN 40 PN 40 Form N, DIN 2501/316L B21 Flange DN 150 PN 16 Form C, DIN 2501/316L B82
Flange DN 40 PN 40 Form E, DIN 2501/316L B22 Flange DN 150 PN 16 Form C, DIN 2501/Hastelloy B83
Flange DN 40 PN 40 V13, DIN 2501/316L B23
Flange DN 150 PN 16 Form C, DIN 2501/ECTFE6) B84
Flange DN 50 PN 40 Form C, DIN 2501/316L B24 Flange DN 150 PN 16 Form C, DIN 2501/PFA6) B85
Flange DN 50 PN 40 Form C, DIN 2501/Hastelloy B25 Flange DN 150 PN 16 Form D, DIN 2501/316L B86
Flange DN 50 PN 40 Form C, DIN 2501/ECTFE6) B26
Flange DN 150 PN 40 Form C, DIN 2501/316L B87
Flange DN 50 PN 40 Form C, DIN 2501/ECTFE B27 Flange DN 150 PN 40 Form C, DIN 2501/Hastelloy B88
(ZB3108)6)
Flange DN 150 PN 40 Form F, DIN 2501/316L C00
Flange DN 50 PN 40 Form C, DIN 2501/PFA6) B28
Flange DN 50 PN 40 Form D, DIN 2501/316L B30 Flange DN 150 PN 40 Form N, DIN 2512/316L C01
Flange DN 200 PN 10 Form C, DIN 2501/ECTFE6) C02
Flange DN 50 PN 40 Form D, DIN 2501/Hastelloy B31
Flange DN 200 PN 16 Form C, DIN 2501/316L C03
Flange DN 50 PN 40 Form F, DIN 2501/316L B32
Flange DN 50 PN 40 Form N, DIN 2501/316L B33 Flange DN 25 PN 40 Form B1, EN 1092-1/316L C04
Flange DN 25 PN 40 Form B1, EN 1092-1/Hastelloy C05
Flange DN 50 PN 40 Form N, DIN 2501/Hastelloy B34
Flange DN 25 PN 40 Form B1, EN/316L/PFA6) C06
Flange DN 50 PN 40 Form E, DIN 2501/316L B35
Flange DN 50 PN 40 V13, DIN 2501/316L B36 Flange DN 25 PN 40 Form B1, EN 1092-1/ C07
Enamelled7)
Flange DN 50 PN 40 R13, DIN 2501/316L B37 Flange DN 25 PN 40 Form B2, EN 1092-1/316L C08
Flange DN 50 PN 64 Form F, DIN 2501/316L B38 Flange DN 25 PN 40 Form F, EN 1092-1/316L C10
Flange DN 50 PN 64 Form N, DIN 2501/Hastelloy B40
Flange DN 25 PN 63 Form B1, EN 1092-1/316L C11
Flange DN 50 PN 64 Form C, DIN 2501/316L B41 Flange DN 25 PN 100 Form B2, EN 1092-1/316L C12
Flange DN 50 PN 64 Form L, DIN 2501/316L B42 Flange DN 40 PN 40 Form B1, EN/316L C13
Flange DN 50 PN 100 Form E, DIN 2501/316L B43
Flange DN 40 PN 40 Form B1, EN 1092-1/PFA6) C14
Flange DN 50 PN 100 Form L, DIN 2501/316L B44 Flange DN 40 PN 40 Form B2, EN/316L C15
Flange DN 65 PN 40 Form C, DIN 2501/316L B45 Flange DN 50 PN 40 Form B1, EN/316L C16
Flange DN 65 PN 40 Form C, DIN 2501/Hastelloy B46
Flange DN 50 PN 40 Form B1, EN 1092-1/Hastelloy C17
Flange DN 65 PN 40 Form C, DIN 2501/ECTFE6) B47 Flange DN 50 PN 40 Form B1,EN 1092-1/ C18
Flange DN 65 PN 40 Form C, DIN 2501/PFA6) B48 Monel ZB2977
Flange DN 65 PN 40 Form F, DIN 2501/316L B50 Flange DN 50 PN 40 Form B1, EN 1092-1/ECTFE6) C20
Flange DN 65 PN 64 Form E, DIN 2501/316L B51 Flange DN 50 PN 40 Form B1, EN/316L/PFA6) C21
Flange DN 80 PN 40 Form C, DIN 2501/316L B52 Flange DN 50 PN 40 Form B1, EN 1092-1/ C22
Flange DN 80 PN 40 Form C, DIN 2501/Hastelloy B53 Enamelled7)
Flange DN 80 PN 40 Form C, DIN 2501/ECTFE6) B54 Flange DN 50 PN 40 Form C, EN 1092-1/316L C23
Flange DN 80 PN 40 Form C, DIN 2501/PFA6) B55
Flange DN 80 PN 40 Form F, DIN 2501/316L B56

Siemens FI 01 · 2015 4/95


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Rigid extension 7ML5747- SITRANS LVL200, Rigid extension 7ML5747-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
77 7 77 - 77 77 7 7 7 77 - 77 7 7
tion in liquid applications such as overflow, high, tion in liquid applications such as overflow, high,
low, and demand applications, as well as pump low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applica- protection. For use in SIL-2 and hazardous applica-
tions. tions.
Flange DN 50 PN 40 Form D, EN/316L C24 Flange 2" 300 lb RF, ANSI B16.5/ECTFE6) C82
Flange DN 50 PN 40 Form D, EN 1092-1/ C25 Flange 2" 300 lb RF, ANSI B16.5/PFA6) C83
Hastelloy
Flange 2" 300 lb RF, ANSI B16.5 Enamelled7) C84
Flange DN 50 PN 40 Form B2, EN 1092-1/316L C26
Flange 2" 300 lb RJF, ANSI B16.5/316L C85
Flange DN 50 PN 40 Form E, EN 1092-1/316L C27 Flange 2" 300 lb ST, ANSI B16.5/316L C86
Flange DN 80 PN 40 Form B1, EN 1092-1/316L C28
Flange 2" 300 lb LG (large groove), C87
Flange DN 80 PN 40 Form B1, EN 1092-1/Hastelloy C30 ANSI B16.5/316L
Flange DN 80 PN 40 Form B1, EN 1092-1/ECTFE6) C31 Flange 2" 300 lb LT, ANSI B16.5/316L C88
Flange DN 80 PN 40 Form B1, EN 1092-1/ C32 Flange 2" 600 lb RF, ANSI B16.5/316L D00
Enamelled7)
Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977 D01

4
Flange DN 80 PN 40 Form B2, EN 1092-1/316L C33
Flange 2" 600 lb RF, ANSI B16.5/ECTFE6) D02
Flange DN 100 PN 16 Form B1, EN 1092-1/316L C34 Flange 2" 600 lb RJF, ANSI B16.5/316L D03
Flange DN 100 PN 16 Form B1, EN 1092-1/ C35
Flange 2" 600 lb LG, ANSI B16.5/316L D04
Hastelloy
Flange 2" 900 lb RJF, ANSI B16.5/316L D05
Flange DN 100 PN 16 Form B1, EN 1092-1/ C36
Enamelled7) Flange 2½" 150 lb RF, ANSI B16.5/316L D06
Flange DN 100 PN 40 Form B1, EN 1092-1/316L C37 Flange 2½" 300 lb RF, ANSI B16.5/316L D07
Flange DN 100 PN 40 Form B1, EN 1092-1/ C38 Flange 3" 150 lb RF, ANSI B16.5/316L D08
Enamelled7) Flange 3" 150 lb RF, ANSI B16.5/Hastelloy D10
Flange DN 100 PN 40 Form C, EN 1092-1/316L C40
Flange 3" 150 lb RF, ANSI B16.5//Monel ZB2977 D11
Flange DN 100 PN 63 Form B2, EN 1092-1/316L C41 Flange 3" 150 lb RF, ANSI B16.5/ECTFE6) D12
Flange DN 150 PN 16 Form B1, EN 1092-1/316L C42 Flange 3" 150 lb RF, ANSI B16.5/PFA6) D13
Flange DN 150 PN 16 Form B1, EN 1092-1/PFA6) C43
Flange 3" 150 lb RF, ANSI B16.5/Enamelled7) D14
Flange DN 150 PN 40 Form B1, EN 1092-1/316L C44 Flange 3" 150 lb FF, ANSI B16.5/316L D15
Flange DN 150 PN 40 Form B1, EN 1092-1/ C45 Flange 3" 150 lb FF, ANSI B16.5/ECTFE6) D16
ECTFE6)
Flange DN 150 PN 40 Form B2, EN 1092-1/316L C46 Flange 3" 150 lb FF, ANSI B16.5/PFA6) D17
Flange 3" 300 lb RF, ANSI B16.5/316L D18
Flange 1" 150 lb ANSI B16.5/316L C47 Flange 3" 300 lb RF, ANSI B16.5/Hastelloy D20
Flange 1"150 lb RF, ANSI B16.5/Hastelloy C48
Flange 1"150 lb RF, ANSI B16.5//Monel ZB2977 C50 Flange 3" 300 lb RF, ANSI B16.5/ECTFE6) D21
Flange 3" 300 lb RF, ANSI B16.5/PFA6) D22
Flange 1" 150 lb RF, ANSI B16.5/ECTFE6) C51 Flange 3" 300 lb RF, ANSI B16.5/Enamelled7) D23
Flange 1"150 lb RF, ANSI B16.5/PFA6) C52
Flange 1" 150 lb RF, ANSI B16.5/Enamelled7) C53 Flange 3" 600 lb RF, ANSI B16.5/316L D24
Flange 3½" 150 lb RF, ANSI B16.5/316L D25
Flange 1" 300 lb RF, ANSI B16.5/316L C54 Flange 3½" 150 lb RF, ANSI B16.5/ECTFE6) D26
Flange 1" 300 lb RF, ANSI B16.5/ECTFE6) C55
Flange 4" 150 lb RF, ANSI B16.5/316L D27
Flange 1" 600 lb RF, ANSI B16.5/316L C56 Flange 4" 150 lb RF, ANSI B16.5/Hastelloy D28
Flange 1½" 150 lb RF, ANSI B16.5/316L C57 Flange 4" 150 lb RF, ANSI B16.5/ECTFE6) D30
Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy C58 Flange 4" 150 lb RF, ANSI B16.5/PFA6) D31
Flange 1½" 150 lb RF, ANSI B16.5/ECTFE6) C60 Flange 4" 150 lb RF, ANSI B16.5/Enamelled7) D32
Flange 1½" 150 lb RF, ANSI B16.5/PFA6) C61 Flange 4" 150 lb LT, ANSI B16.5/316L D33
Flange 1½" 150 lb RF, ANSI B16.5 Enamelled7) C62 Flange 4" 300 lb RF, ANSI B16.5/316L D34
Flange 1½" 150 lb FF, ANSI B16.5/ECTFE6) C63 Flange 4" 300 lb RF, ANSI B16.5/Hastelloy D35
Flange 1½" 300 lb RF, ANSI B16.5/316L C64 Flange 4" 300 lb RF, ANSI B16.5/ECTFE6) D36
Flange 1½" 300 lb RF, ANSI B16.5//Monel ZB2977 C65 Flange 4" 300 lb RJF, ANSI B16.5/316L D37
Flange 1½" 300 lb RF, ANSI B16.5/ECTFE6) C66 Flange 4" 300 lb LG, ANSI B16.5/316L D38
Flange 1½" 600 lb RF, ANSI B16.5/316L C67 Flange 4" 300 lb LT, ANSI B16.5/316L D40
Flange 2" 150 lb RF, ANSI B16.5/316L C68 Flange 4" 600 lb RF, ANSI B16.5/316L D41
Flange 2" 150 lb RF, ANSI B16.5/Hastelloy C70 Flange 4" 600 lb RJF, ANSI B16.5/316L D42
Flange 2" 150 lb RF, ANSI B16.5//Monel ZB2977 C71 Flange 5" 150 lb RF, ANSI B16.5/316L D43
Flange 2" 150 lb RF, ANSI B16.5/ECTFE6) C72 Flange 6" 150 lb RF, ANSI B16.5/316L D44
Flange 2" 150 lb RF, ANSI B16.5/PFA6) C73 Flange 6" 150 lb RF, ANSI B16.5/Hastelloy D45
Flange 2" 150 lb RF, ANSI B16.5/Enamelled7) C74 Flange 6" 150 lb RF, ANSI B16.5/ECTFE6) D46
Flange 2" 150 lb FF, ANSI B16.5/316L C75 Flange 6" 150 lb RF, ANSI B16.5/PFA6) D47
Flange 2" 150 lb FF, ANSI B16.5/ECTFE6) C76 Flange 6" 150 lb RJF, ANSI B16.5/316L D48
Flange 2" 150 lb SG (small groove), C77 Flange 6" 300 lb RF, ANSI B16.5/316L D50
ANSI B16.5/316L
Flange 8" 150 lb RF, ANSI B16.5/316L D51
Flange 2" 300 lb RF, ANSI B16.5/316L C78
Flange 8" 150 lb RF, ANSI B16.5/ECTFE6) D52
Flange 2" 300 lb RF, ANSI B16.5/Hastelloy C80
Flange 1" BS.10 Table E/316L D53

4/96 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVL200, Rigid extension 7ML5747- SITRANS LVL200, Rigid extension 7ML5747-
Compact vibrating level switch for material detec- Compact vibrating level switch for material detec-
77 7 77 - 77 77 7 7 7 77 - 77 7 7
tion in liquid applications such as overflow, high, tion in liquid applications such as overflow, high,
low, and demand applications, as well as pump low, and demand applications, as well as pump
protection. For use in SIL-2 and hazardous applica- protection. For use in SIL-2 and hazardous applica-
tions. tions.
Flange 1" BS.10 Table E/PFA6) D54 Rigid Extension 316L Ra  0.8 μm
Flange 1½" BS.10 Table E/316L D55 80 ... 500 mm D0
Flange 3½" BS.10 Table E/316L D56 501 ... 1 000 mm D1
Flange 4" BS.10 Table E/ECTFE6) D57 1 001 ... 1 500 mm D2
Flange DN 40 10K, JIS/316L D58 1 501 ... 2 000 mm D3
Flange DN 50 10K, JIS/316L D60 2 001 ... 2 500 mm D4
Flange DN 80 10K, JIS/316L D61 2 501 ... 3 000 mm D5
Flange DN 100 10K, JIS/316L D62 3 001 ... 3 500 mm D6
Adapter/Process temperature 3 501 ... 4 000 mm D7
Rigid Extension 316L Ra  0.3 μm
4
Without adapter/-50 ... +150 °C 1
With adapter/-50 ... +200 °C8) 2 80 ... 500 mm E0
With adapter/-50... +250 °C 3 501 ... 1 000 mm E1
With gas-tight leadthrough/-50 ... +150 °C 4 1 001 ... 1 500 mm E2
With gas-tight leadthrough/-50 ... +250 °C 5 1 501 ... 2 000 mm E3
Housing/ Cable entry 2 001 ... 2 500 mm E4
Aluminium IP66/IP67/M20x1.5 A 2 501 ... 3 000 mm E5
Aluminium IP66/IP67/½" NPT B 3 001 ... 3 500 mm E6
316L stainless steel (electropolished) C 3 501 ... 4 000 mm E7
IP66/IP67/M20X1.59)10)
Rigid Extension Enamelled version7)
316L stainless steel (electropolished) D
IP66/IP67/½" NPT9)10) 80 ... 250 mm F0
251 ... 500 mm F1
NOTE:
501 ... 750 mm F2
When selecting a Rigid Extension option,
extension coating must match the process 751 ... 1 000 mm F3
connection coating and the material and 1 001 ... 1 250 mm F4
surface roughness type. 1 251 ... 1 500 mm F5
Rigid Extension 316L Rigid Extension Hastelloy
80 ... 500 mm A0 80 ... 500 mm G0
501 ... 1 000 mm A1 501 ... 1 000 mm G1
1 001 ... 1 500 mm A2 1 001 ... 1 500 mm G2
1 501 ... 2 000 mm A3 1 501 ... 2 000 mm G3
2 001 ... 2 500 mm A4 2 001 ... 2 500 mm G4
2 501 ... 3 000 mm A5 2 501 ... 3 000 mm G5
3 001 ... 3 500 mm A6 3 001 ... 3 500 mm G6
3 501 ... 4 000 mm A7 3 501 ... 4 000 mm G7
Rigid Extension ECTFE coated6) Rigid Extension Monel
80 ... 500 mm B0 80 ... 500 mm H0
501 ... 1 000 mm B1 501 ... 1 000 mm H1
1 001 ... 1 500 mm B2 1 001 ... 1 500 mm H2
1 501 ... 2 000 mm B3 1 501 ... 2 000 mm H3
2 001 ... 2 500 mm B4 2 001 ... 2 500 mm H4
2 501 ... 3 000 mm B5 2 501 ... 3 000 mm H5
Rigid Extension PFA coated6) 1)
Available with Adapter/Process temperature options 1, 3, 4, and 5 only
80 ... 500 mm C0 2)
Available with Electronics option 4 only
501 ... 1 000 mm C1 3)
Available with Adapter/Process temperature options 1 and 3 only
1 001 ... 1 500 mm C2 4)
Extension length restricted to 2 956 mm
1 501 ... 2 000 mm C3 5)
Available with Housing/Cable entry option B only
2 001 ... 2 500 mm C4 6)
Available with Adapter/Process temperature options 1 and 4 only
2 501 ... 3 000 mm C5 7)
Available with Adapter/Process temperature options 1, 2, and 4 only
8)
Available with enamelled Process connection and Extension options only
9)
Available with Approval options A, B, C only
10)
Not available with SIL/IEC61508 Certificate of conformity
(SIL-2 min. and max. detection)

Siemens FI 01 · 2015 4/97


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200
Selection and Ordering data Order code Selection and Ordering data Order code
Further designs Spare Parts and Accessories
Please add "-Z" to Article No. and specify Order Electronics module SITRANS LVL200 Relay 7ML1830-1NC
code(s). Electronics module SITRANS LVL200 Contactless 7ML1930-6AA
Cleaning including Certificate W01 Lock fitting, unpressurized, G1" A/316L 7ML1930-1DQ
(oil, grease and silicone free) Lock fitting, unpressurized, 1" NPT/316L 7ML1930-1DR
Enter the total insertion length in plain text Y01 Lock fitting, unpressurized, G1 ...1/2" A/316L 7ML1930-1DS
description, max. 4 000 mm (157.48 inch) Lock fitting, unpressurized, 1 ... 1/2" NPT/316L 7ML1930-1DT
Identification Label (measurement loop) stainless Y17 Lock fitting, -1 ... 16 bar, G1" A/316L 7ML1930-1DU
steel: max. 16 characters add in plain text Lock fitting, -1 ... 16 bar, 1" NPT/316L 7ML1930-1DV
Identification Label (measurement loop) Foil: Y18 Lock fitting, -1 ... 16 bar, G1 ... 1/2" A/316L 7ML1930-1DW
max. 16 characters add in plain text
Lock fitting, -1 ... 16 bar, 1 ... 1/2" NPT/316L 7ML1930-1DX
Acceptance test certificate 3.1 NACE MR 0775 for D07 Lock fitting, -1 ... 64 bar, G1" A/316L 7ML1930-1EA
material EN102041)
Lock fitting, -1 ... 64 bar, 1" NPT/316L 7ML1930-1EB
Acceptance test certificate 3.1 for instrument C12
Lock fitting, -1 ... 64 bar, G1 ... 1/2" A/316L 7ML1930-1EC
EN102041)
4 Acceptance test Certificate 2.2 for material
EN102041)
C15
Lock fitting, -1 ... 64 bar, 1 ... 1/2" NPT/316L
1)
7ML1930-1ED
Listed Certificates are not available with all configurations, please contact
factory for more information
Functional Safety (SIL 2). Device suitable for use in C20
accordance with IEC 61508 and IEC 615111)
Dye penetration test + 3.1 certificate/instrument1) C13
X-ray test + 3.1 certificate/instrument1) C14
Positive material identification test C16
+ 3.1 certificate/instrument1)
Roughness test + 3.1 certificate/instrument1) C18
Pressure test + 3.1 certificate/instrument1) C31
Helium leak test + 3.1 certificate/instrument1) C32
Ferrite measuring accuracy to DIN32514-1 C60
+ 3.1 certificate/instrument1)
Pressure test according to Norsok C61
+ 3.1 certificate/instrument1)
Additional Operating Instructions Article No.
LVL200 Extended (DPDT Relay)
• English 7ML1998-5KW01
• French 7ML1998-5KW11
• Spanish 7ML1998-5KW21
• German 7ML1998-5KW31
LVL200 (Contactless electronic switch)
• English 7ML1998-5KV01
• French 7ML1998-5KV11
• Spanish 7ML1998-5KV21
• German 7ML1998-5KV31
Electronics module LVL200 Relay
• English 7ML1998-5LS01
• French 7ML1998-5LS11
• Spanish 7ML1998-5LS21
• German 7ML1998-5LS31
This device is shipped with the Siemens Milltronics
manual DVD containing the Operating Instructions
library.

4/98 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Options
LVL200 threaded welded socket Lock fitting
G¾" A/316L G1" A/316L LVL200 extended LVL200 extended LVL200 extended
64 bar 16 bar unpressurized

32 (1.26) 39 (1.54)
G¾" G1"

(1.16)
(1.26)

29,5
32

53 (2.09) 60 (2.36)

SITRANS LVL200 welded socket and lock fitting, dimensions in mm (inch)

Siemens FI 01 · 2015 4/99


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Characteristic curves
Ambient/Process temperature Temperature range with
temperature adapter
70 ºC
Ambient temperature in °C (°F)

(158 ºF)

40 ºC
(104 ºF)

0 ºC
-50 ºC (32 ºF) 0 ºC 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC
(-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF)

4 -40 ºC
(-40 ºF)
Process temperature in °C (°F)

Process pressure with switch position 0.7 g/cm³ (mode switch)

64
Process pressure in bar (psi g)

(928)

40
(580)

20
(290)

-50 ºC 0 ºC 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC


-1 (482 ºF)
(-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
(-14.5)
Process temperature in °C (°F)

Process pressure with switch position 0.5 g/cm³ (mode switch)

64
Process pressure in bar (psi g)

(928)

40
(580)

20
(290)

-50 ºC 0 ºC 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC


-1
(-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF)
(-14.5)
Process temperature in °C (°F)

SITRANS LVL200 Process Pressure/Process Temperature/Ambient Temperature derating curves

4/100 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Dimensional drawings
SITRANS LVL200 (Standard)
Stainless Steel enclosure Aluminium enclosure
~ 59 ~116 (4.57)
(2.32 )
Ø84 (3.31)
Ø 80
(3.15)
M20 x 1.5

125 (4.92)
(4.41)
112
M20 x 1.5 or
M20 x 1,5 or ½" NPT
½" NPT

Threaded Tri-clamp Cone DN 25 Temperature adapter


4
(0.73)
18.5

SW 32
(G ¾" A, ¾" NPT)
SW 41
(G 1" A, 1" NPT)
53 (2.09) (1.42)

(2.24)
36

57
(2.60)
66

G ¾" A, ¾" NPT


G 1" A, 1" NPT

178 (7.01)
(2.17)
55

Bolting DN 40 Flange Gas-tight leadthrough


(0.75)
19

(1.34)
34
(1.97)

Ø33.7 (1.33)
50

(2.09)
53
(2.09)
53

SITRANS LVL200 (Standard), dimensions in mm (inch)

Siemens FI 01 · 2015 4/101


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

SITRANS LVL200 (Extended) Sensor length (L)


316L, Hastelloy C4 (2.4610) 80 ... 6 000 mm (3.15 ... 236.2 inch)
Stainless Steel Enclosure Aluminium Enclosure
~ 59 Hastelloy C4 (2.4610) enamelled 80 ... 1 500 mm (3.15 ... 59.06 inch)
(2.32) ~ 116
Ø 80 Ø 84 316L, ECTFE coated 80 ... 3 000 mm (3.15 ... 118.1 inch)
(4.57)
(3.15) (3.31) 316L, PFA coated 80 ... 3 000 mm (3.15 ... 118.1 inch)

M20 x1.5

(4.41) 125
112

(4.92)
M20x1.5 or
M20x 1,5 or ½" NPT
½" NPT

Threaded Tri-clamp Cone DN 25

4
32 (G ¾" A, ¾" NPT)
18.5 41 (G 1" A, 1" NPT)
(0.73) 57
36 (2.24)
(1.42)

G ¾" A, ¾" NPT


G 1" A, 1" NPT

Temperature adapter
L L L

Bolting DN 40 Flanged Gas-tight leadthrough

178
(7.01)

19
(0.75)

50
(1.97)
34
(1.34)

L L

SITRANS LVL200 (Extended), dimensions in mm (inch)

4/102 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVL200

■ Schematics
Relay (DPDT)

+ –
L1 N
1

20 - 72 V DC 2
20 - 253 V AC
3 1 2 3 4 5 6 7 8
1 Control lamp
6
2 DIL switch for characteristics reversal

3 DIL switch for sensitivity adjustment


4 Relay
4 Ground terminal output
5 Connection terminals Relay
output
Voltage
supply
4

Contactless

20-253V AC/DC 1 2 1 2
I max 400 mA 1

L
1 2
L N N 2
A ≥0.5g/cm 1 Control lamp

2 DIL switch for mode adjustment


≥0.7g/cm 3
B
1 2 3 DIL switch for switching point adaptation
5 4
4 Ground terminal L1 N
5 Connection terminals AC + –
DC – +

Voltage
supply

NAMUR

NAMUR + –
(IEC 60947-5-6) 1
+ -
max.
Simul.
6 2 1 Control lamp 1 2
min. 3
2 DIL switch for characteristics reversal
5 1 2
4 3 DIL switch for sensitivity adjustment + –
4 Ground terminal
Amplifier according to NAMUR
5 Simulation key
IEC 60947-5-6, approx. 8.2 V
6 Connection terminals

SITRANS LVL200 connections

Siemens FI 01 · 2015 4/103


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100

■ Overview ■ Configuration
Installation

Rigid extension with


sliding sleeve
Position tines vertically to
avoid product build-up:
* use a 50 mm open-end
wrench to turn the process
connection until the tine
orientation marking faces up
or down.

L
Protection in case of high
O material loading.

4 Cable gland faces


downward to avoid
water penetration.
SITRANS LVS100 is a vibrating point level switch for material
detection in bulk solids.

■ Benefits Tine orientation marking


• High resistance to mechanical forces facing sideways.

• Sliding sleeve options for adjustable insertion length and ease


of cleaning Use angle mounting for
flowing material only. If angle
• Rotatable enclosure for ease of installation and wiring
mounting is required with high
• Suitable for point level detection of materials starting at a bulk material loading, customer-
density of 30 g/l (1.9 lb/ft3) supplied protection from
• Customer desired extensions up to 4 000 mm (157.48 inch) falling material must be in
place.

■ Application
* max. deviation max. length L
SITRANS LVS100 detects high, low or demand levels of dry bulk from vertical O
solids in bins, silos or hoppers.
5° 4.0 m
SITRANS LVS100 has a compact design and can be top, side, 45° 1.2 m
or angle mounted. The vibrating fork design ensures the tines
are kept clean. The unique design of the fork and crystal assem- > 45° 0.6 m
bly eliminates false high level readings even if tines become
damaged. SITRANS LVS100 installation, dimensions in mm (inch)
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material,
the change in vibration is detected by the electronic circuitry
which causes the relay to change state after a one second delay.
When the fork is free from material pressure, full vibration
resumes and the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers

4/104 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100

■ Technical specifications
Mode of Operation Design
Measuring principle Vibrating point level switch Material

Input • Enclosure Epoxy coated aluminum


Process connection • Thread 1¼" NPT [(Taper),
Measured variable High, low and demand ANSI/ASME B1.20.1],
Measuring frequency 200 Hz R 1½" [(BSPT), EN 10226]
• Thread R 1½" [(BSPT),
Output EN 10226], ½" NPT [(Taper),
ANSI/ASME B1.20.1], sliding sleeve
Relays DPDT relay [min. length 500 mm (19.69 inch)]
Relay delay From loss of vibration: • Thread material:
approximately 1 second stainless steel 304 (1.4301) or
316TI (1.4571) depending on
From resumption of vibration: configuration
approximately 1 ... 2 s
Tine material Stainless steel 316TI (1.4571)
Signal delay Probe uncovered to covered:
approximately 1 s Degree of protection IP66/Type 4/NEMA 4

4
Probe covered to uncovered: Conduit entry 2 x M20x1.5 or 2 x ½" NPT
approximately 1 ... 2 s Weight Standard version, no extensions:
Relay fail-safe High or low, switch selectable approx. 1.7 kg (3.7 lb)

Alarm output Relay 8 A at 250 V AC, non-inductive Power supply • 19 ... 230 V AC, +10 %,
50 ... 60 Hz, 8 VA
Relay 5 A at 30 V DC, non-inductive • 19 ... 40 V DC, +10 %, 1.5 W
Sensitivity High or low, switch selectable Certificates and approvals • CSA/FM General Purpose
• CE
Rated operating conditions
• CSA/FM Dust Ignition Proof
Installation conditions • RCM
• ATEX II 1/2 D
• Location Indoor/outdoor • IECex
Ambient conditions
• Ambient temperature -40 ... +60 °C (-40 ... +140 °F)
• Installation category III
• Pollution degree 2
Medium conditions
• Process temperature -40 ... +150 °C (-40 ... +302 °F)
• Max. threaded bushing temperature 60 °C (140 °F)
• Max. enclosure surface temperature 90 °C (194 °F)
(Category 2D)
• Max. extension surface temperature 150 °C (302 °F)
(Category 1D)
• Pressure (vessel) Max. 10 bar g (145 psi g)
European Pressure Directive
97/23/EC: Category 1
Minimum material density Approx. 30 g/l (1.9 lb/ft3)

Siemens FI 01 · 2015 4/105


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS100

Selection and Ordering data Article No. ■ Dimensional drawings


SITRANS LVS100, standard 7ML5735-
Vibrating point level switch for high or low level
77 7 77 - 07A 0
detection of bulk solids. Sensitivity > 30 g/l.
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal.

75 (2.95)
Input Voltage

(2.36)
60
DPDT Relay - 19 ... 230 V AC, 19 ... 40 V DC ¢ 1
DPDT Relay - 19 ... 230 V AC, 19 ... 40 V DC ¢ 2
(stocked version)1)
Process temperature
Up to 150 °C (302 °F) ¢ A 60
Process connection (2.36)
Threaded
R 1½" [(BSPT), EN 10226] ¢ A 120 (4.72)
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ B Tine orientation

4 R 1½" [(BSPT), EN 10226] DIN 2999 thread,


sliding sleeve - min. length 500 mm (19.69 inch)2)
¢ C marking

150 (5.91)
1½" NPT [(Taper), ANSI/ASME B1.20.1] , ¢ D
sliding sleeve [min. length 500 mm (19.69 inch)]2) Threaded bushing
[max. temp.
Extension length 80 °C (176 °F)] Zone 21
Stainless steel 316TI (1.4571) (cat. 2)
Standard length, 170 mm (6.69 inch) ¢ 11 Zone 20
Add Order code Y01 and plain text: (cat. 1)
"Insertion length ... mm"

170 ... 4 000 (6.69 ... 157.48):


Stainless steel 304 (1.4301)

Customer specified rigid


• 300 ... 500 mm (11.81 ... 19.69 inch) ¢ 12 Customer supplied
process flange
• 501 ... 1 000 mm (19.72 ... 39.37 inch) ¢ 13
• 1 001 ... 1 500 mm (39.41 ... 59.06 inch) ¢ 14
• 1 501 ... 2 000 mm (59.09 ... 78.74 inch) ¢ 15
Tine
• 2 001 ... 2 500 mm (78.78 ... 98.43 inch) 16

Standard fork
125 (4.92):
• 2 501 ... 3 000 mm (98.46 ... 118.11 inch) 17
• 3 001 ... 3 500 mm (118.15 ... 137.80 inch) 18
• 3 501 ... 4 000 mm (137.83 ... 157.48 inch) 20
Approvals
CSA/FM General Purpose, CE, RCM ¢ A
CSA/FM Class II, Div. 1, Group E, F, G, Class III, ¢ B
ATEX II 1/2 D, RCM SITRANS LVS100, dimensions in mm (inch)
IEC-Ex t IIIC Da/Db C
1) Only available with the following configurations 7ML5735-2AA11-0AA0 or ■ Schematics
7ML5735-2AB11-0AA0
2) Not available with extension length options 11, 12
Universal voltage (DPDT relay)
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Alarm
Selection and Ordering data Order code output FSH/FSL
Further Designs relay adjustment
Please add "-Z" to Article No. and specify Order Sensitivity adjustment:
code(s). B = factory setting,
A = decreased
Total insertion length: Enter the total insertion length Y01
in plain text description, max. (50 mm increments)
Signal bulb inserted in M20 cable gland1) A20
Operating Instructions Article No. 876 543 21
LED
Multi-language 7ML1998-5FT63
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
AC: Terminal 1: L
Spare Parts Terminal 2: N
19 ... 230 V AC, +10 %, 50 ... 60 Hz, 8 VA
Replacement Electronics Module LVS100 DPDT 7ML1830-1NS
Relay (19 ... 253 V AC, 19 ... 55 V DC) DC: Terminal 1: +
R 1½" [(BSPT), EN 10226] DIN 2999 thread, 7ML1830-1NT Terminal 2: -
sliding sleeve 19 ... 50 V DC, +10 %, 2 W
1½" NPT [(Taper), ANSI/ASME B1.20.1] , 7ML1830-1NU
sliding sleeve [min. length 500 mm (19.69 inch)] SITRANS LVS100 connections
1)
Available only with approval CE

4/106 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200

■ Overview ■ Application
The standard LVS200 detects high, low, or demand levels of dry
bulk solids in bins, silos, or hoppers. The liquid/solid interface
version can also detect settled solids within liquids or solids
within confined spaces such as feed pipes. It is designed to
ignore liquids in order to detect the interface between a solid
and a liquid.
A pipe extension version is available with either the standard or
liquid/solid interface electronics and fork, separated by a cus-
tomer supplied 1 inch pipe.
SITRANS LVS200 has an optional 4 ... 20 mA output for monitor-
ing buildup on the fork to determine when preventative mainte-
nance should be performed in sticky applications.
The LVS200 has a compact design and can be top, side or angle
mounted. The vibrating fork design ensures the tines are kept

4
clean. The unique design of the fork and crystal assembly elim-
inates false high level readings even if tines become damaged.
A signal from the electronic circuit excites a crystal in the probe
SITRANS LVS200 is a vibrating point level switch for high, low, causing the fork to vibrate. If the fork is covered by material, the
or demand level detection of bulk solids. change in vibration is detected by the electronic circuitry which
causes the relay to change state after a one second delay.
When the fork is free from material pressure, full vibration
■ Benefits resumes and the relay reverts to its normal condition.
• High resistance to mechanical forces • Key Applications: dry bulk solids in bins, silos, hoppers or
• Strong vibration resistance to high bulk material loads settled solids within liquids (interface version)
• Rotatable enclosure for convenient wiring
• Suitable for low density material: standard version, 20 g/l
(1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3)
and low density option min. 5 g/l (0.3 lb/ft3)
• Customer desired extensions up to 20 000 mm (787 inch)
• Optional detection of solids within liquid
• Durable short fork option with 165 mm (6.5 inch) insertion
length

Siemens FI 01 · 2015 4/107


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200

■ Technical specifications
Mode of operation Medium conditions
Measuring principle Vibrating point level switch • Process temperature • All except CSA Class II, Group G:
-40 ... +150 °C (-40 ... +302 °F)
Input • CSA Class II, Group G:
-40 ... +140 °C (-40 ... +284 °F),
Measured variable High, low and demand CSA temperature code T3B
Measuring frequency • Max. threaded bushing temperature 60 °C (140 °F)
• Standard 125 Hz • Max. enclosure surface temperature 90 °C (194 °F)
• Liquid/solid interface and short 350 Hz (Category 2D)
fork version • Max. extension surface temperature 150 °C (302 °F)
(Category 1D)
Output
• Pressure (vessel) Max. 10 bar g (145 psi g) European
PNP Open collector: Pressure Directive 97/23/EC:
Permanent load max. 0.4 A, Category 1
short-circuit and overload protected
Turn-on voltage: max. 50 V (reverse • Minimum material density • Standard version: approx. 20 g/l
protection) (1.2 lb/ft3)
• Liquid/solid interface version:
2-wire without contact Load current: approx. 50 g/l (3 lb/ft3)

4
• Min. 10 mA • Optional low density version:
• Max. 500 mA permanent approx. 5 g/l (0.3 lb/ft3)
• Max. 2A < 200 ms
• Max. 5A < 50 ms Design
Voltage drop on the electronic Material
module: max. 7 V with closed • Enclosure Epoxy coated aluminum
electric circuit Process connection • Thread 1½" NPT [(Taper),
Cutoff current with open electric ANSI/ASME B1.20.1], R ½" [(BSPT),
circuit: max. 5 mA EN 10226] and flange options
Relays • Optional sliding bushing with
2" NPT [(Taper), ANSI/ASME
• Version with 1 relay SPDT relay B1.20.1] or BSP thread
• Version with 2 relays DPDT relay • Thread material: stainless steel 303
Relay delay • From loss of vibration: (1.4301)
approximately 1 second Tine material Stainless steel 316TI (1.4571),
• From resumption of vibration: PTFE-coated tines are available
approximately 1 ... 2 seconds upon special request
Signal delay • Probe uncovered to covered: Degree of protection IP65/Type 4/NEMA 4
approximately 1 second Conduit entry 2 x M20x1.5 or 2 x ½" NPT
• Probe covered to
uncovered: approximately Weight • Standard version, no extensions:
1 ... 2 seconds approx 2.0 kg (4.4 lb)
• Solids/liquids version, no extensions:
Relay fail-safe High or low, switch selectable approx. 1.9 kg (4.2 lb)
Alarm output • Relay 8 A at 250 V AC,
non-inductive Power supply • 19 ... 230 V AC, +10 %,
• Relay 5 A at 30 V DC, 50 ... 60 Hz, 8 VA
non-inductive • 19 ... 55 V DC, +10 %, 1.5 W
mA output 8/16 mA or 4 ... 20 mA Certificates and approvals • CSA/FM General Purpose
• Resolution 4 ... 20 mA ± 0.1 mA • CE
• CSA/FM Dust Ignition Proof
Sensitivity High or low, switch selectable • RCM
Rated operating conditions • ATEX II 1/2 D
• CSA/FM IS Class I, II, III Div. 1,
Installation conditions Groups A, B, C, D, E, F, G,
• Location Indoor/outdoor FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with
Ambient conditions power supply option 5 and 6
• Ambient temperature -40 ... +60 °C (-40 ... +140 °F) • ATEX II 1G and 1/2 G Eex ia IIC;
• Installation category III ATEX II 1D and 1/2 D, available
• Pollution degree 2 only with power supply option 5

4/108 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVS200, standard 7ML5731- SITRANS LVS200, standard 7ML5731-
SITRANS LVS200 is a vibrating point level switch SITRANS LVS200 is a vibrating point level switch
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
for high, low, or demand level detection of bulk for high, low, or demand level detection of bulk
solids. solids.
Click on the Article No. for the online configu- Stainless steel 316L (1.4404)
ration in the PIA Life Cycle Portal. Standard length, 235 mm (9.25 inch) 31
Power supply Add Order code Y01 and plain text:
19 ... 230 V AC, 19 ... 55 V DC, one relay output ¢ 1 "Insertion length ... mm"
(SPDT)1)
300 ... 500 mm (11.81 ... 19.69 inch) 32
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs 2
(DPDT)1) 501 ... 750 mm (19.72 ... 29.53 inch) 33
18 ... 50 V DC PNP1) ¢ 3 751 ... 1 000 mm (29.57 ... 39.37 inch) 34
1 001 ... 1 250 mm (39.41 ... 49.21 inch) 35
19 ... 230 V AC/DC without contact, 2-wire loop 4
powered1) 1 251 ... 1 500 mm (49.25 ... 59.06 inch) 36
7 ... 9 V DC (requires NAMUR switch amplifier) 5 1 501 ... 1 750 mm (59.09 ... 68.90 inch) 37
NAMUR IEC 60947-5-6, 2-wire2) 1 751 ... 2 000 mm (68.94 ... 78.74 inch) 38
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
19 ... 230 V AC, 19 ... 55 V DC, one relay output }¢ 7
6 2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
41
42
4
(SPDT) basic version4)5) 2 501 ... 2 750 mm (98.46 ... 108.27 inch) 43
Process temperature 2 751 ... 3 000 mm (108.31 ... 118.11 inch) 44
Without temperature isolator }¢ A 3 001 ... 3 250 mm (118.15 ... 127.95 inch) 45
With temperature isolator B 3 251 ... 3 500 mm (127.99 ... 137.80 inch) 46
Separated enclosure - cable length 1.5 m (4.92 ft) C 3 501 ... 3 750 mm (137.83 ... 147.64 inch) 47
[max. temperature process 150 °C (302 °F)/ 3 751 ... 4 000 mm (147.68 ... 157.48 inch) 48
max. temperature electronics 60 °C (140 °F)]
Material process connection/extension
Separated enclosure - cable length 4.0 m (13.12 ft) D
[max. temperature process150 °C (302 °F)/ Stainless steel threads 304 (1.4301), }¢ 1
max. temperature electronics 60 °C (140 °F)] flanges 321 (1.4541), Tri-clamp 304 (1.4301)8)
Stainless steel 316L (1.4404)9) 2
Process connection
Threaded Approvals
CSA/FM Dust Ignition Proof, RCM }¢ A
R 1½" [(BSPT), EN 10226] }¢ A ATEX II 1/2 D, RCM }¢ B
1½" NPT [(Taper), ANSI/ASME B1.20.1] }¢ B CSA/FM General Purpose, RCM ¢ C
G 2" [(BSPP), EN ISO 228-1], sliding sleeve C CE, RCM ¢ D
[min. length 500 mm (19.69 inch)]6)
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
2" NPT [(Taper), ANSI/ASME B1.20.1], D E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
sliding sleeve [min. length 500 mm (19.69 inch)]6) Ex ia IIC, RCM
Flanged ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
DN 100 PN 6, EN 1092-17) E 1/2D, RCM
DN 100 PN 16, EN 1092-1 F IEC-Ex t IIIC Da/Db G
2" ASME 150 lb B16.5 G 1)
Available with Approval options A ... D, G only
3" ASME 150 lb B16.5 H 2)
Available with Approval options D, E, F only
4" ASME 150 lb B16.5 J 3)
Available with Approval options B, D, G only
2" Tri-clamp (DN 50) ISO 2852 K 4)
Available with configurations 7ML5731-7AA11-1BA0 or
7ML5731-7AB11-1AA0 only
Extension length 5)
Stainless steel 304 (1.4301) Basic version is cost effective and offers fast delivery
6)
Standard length, 235 mm (9.25 inch) }¢ 11 Not available with extension length options 11, 12, 31, 32
7)
Max. 6 bar (87 psi)
Add Order code Y01 and plain text: 8)
"Insertion length ... mm" Available with option extension length 11 ... 28
9)
• 300 ... 500 mm (11.81 ... 19.69 inch) ¢ 12 Available with option extension length 31 … 48
• 501 ... 750 mm (19.72 ... 29.53 inch) ¢ 13
¢ We can offer shorter delivery times for configurations designated with the
• 751 ... 1 000 mm (29.57 ... 39.37 inch) ¢ 14 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
• 1 001 ... 1 250 mm (39.41 ... 49.21 inch) ¢ 15 } Available ex stock. For details see page 9/5 in the appendix.
• 1 251 ... 1 500 mm (49.25 ... 59.06 inch) ¢ 16
• 1 501 ... 1 750 mm (59.09 ... 68.90 inch) ¢ 17
• 1 751 ... 2 000 mm (68.94 ... 78.74 inch) ¢ 18
• 2 001 ... 2 250 mm (78.78 ... 88.58 inch) ¢ 21
• 2 251 ... 2 500 mm (88.62 ... 98.43 inch) ¢ 22
• 2 501 ... 2 750 mm (98.46 ... 108.27 inch) ¢ 23
• 2 751 ... 3 000 mm (108.31 ... 118.11 inch) ¢ 24
• 3 001 ... 3 250 mm (118.15 ... 127.95 inch) ¢ 25
• 3 251 ... 3 500 mm (127.99 ... 137.80 inch) ¢ 26
• 3 501 ... 3 750 mm (137.83 ... 147.64 inch) ¢ 27
• 3 751 ... 4 000 mm (147.68 ... 157.48 inch) ¢ 28

Siemens FI 01 · 2015 4/109


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data Order code Selection and Ordering data Article No.
Further Designs SITRANS LVS200, short fork for liquids/ 7ML5732-
Please add "-Z" to Article No. and specify Order solids interface
77 7 77 - 77 A 0
code(s). Vibrating point level switch for solids or solids
within liquid interface applications, and high load
Total insertion length: Enter the total insertion length Y01 applications with short insertion requirements
in plain text description, max. 4 000 mm
(157.48 inch) Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal.
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
Measuring-point number/identification Power supply
(max. 27 characters); specify in plain text 19 ... 230 V AC, 19 ... 55 V DC, one relay output ¢ 1
Enhanced sensitivity > 5 g/l via electronics and K05 (SPDT)
increased fork length to 195 mm (7.68 inch)3) 19 ... 230 V AC, 19 ... 55 V DC, two relay outputs 2
(DPDT)
Enhanced sensitivity < 5 g/l via electronics, G01 18 ... 50 V DC PNP 3
increased fork length to 195 mm (7.68 inch),
and increased aluminum fork width 1)3) 19 ... 230 V AC/DC without contact, 2-wire loop 4
powered
Signal bulb inserted in M20 cable gland2) A20 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire1) 5

4
NAMUR 8/16 mA switch amplifiers available, Process temperature
contact factory for pricing Without temperature isolator ¢ A
Operating Instructions Article No. With temperature isolator B
Multi-language 7ML1998-5FT63 Separated enclosure - cable length 1.5 m (4.92 ft) C
This device is shipped with the Siemens Milltronics [max. temperature process 150 °C (302 °F)/
manual DVD containing the ATEX Quick Start and max. temperature electronics 60 °C (140 °F)]
Operating Instructions library. Separated enclosure - cable length 4.0 m (13.12 ft) D
Spare Parts [max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Replacement Electronics Module (125 Hz) 7ML1830-1KL
[19 ... 230 V AC, 19 ... 55 V DC, one relay output Process connection
(SPDT)] Threaded
R 1½" [(BSPT), EN 10226] ¢ A
Sliding sleeve, 2" BSP (ISO 228) 7ML1830-1JM
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ B
Sliding sleeve, 2" NPT (ASME B1.20.1) 7ML1830-1JN G 2" [(BSPP), EN ISO 228-1], sliding sleeve C
Namur Isolator switch amplifier relay output A5E03496569 [min. length 500 mm (19.69 inch)]2)
KFD2-SR2-Ex1.W 2" NPT [(Taper), ANSI/ASME B1.20.1], D
sliding sleeve [min. length 500 mm (19.69 inch)]2)
Available ex stock
Flanged
For details see page 9/5 in the appendix.
DN 100 PN 6, EN 1092-13) E
SITRANS LVS200, standard, power supply 7, 7ML5731- DN 100 PN 16, EN 1092-1 F
process temperature A, process connection A, 7AA11-1BA0
extension length 11, material process connection/ 2" ASME 150 lb B16.5 G
extension 1, and approval B 3" ASME 150 lb B16.5 H
SITRANS LVS200, standard, power supply 7, 7ML5731- 4" ASME 150 lb B16.5 J
process temperature A, process connection B, 7AB11-1AA0 2" Tri-clamp (DN 50) ISO 2852 K
extension length 11, material process connection/
extension 1, and approval A Extension length
Stainless steel 304 (1.4301)
1) Available only with power supply 1 and Approval C, D and with Standard length, 165 mm (6.50 inch) ¢ 11
Process connection flange E ... J
2) Available with Approval option D only Add Order code Y01 and plain text:
3) "Insertion length ... mm"
K05 and G01 are not available together
200 ... 500 mm (7.87 ... 19.69 inch) ¢ 12
501 ... 750 mm (19.72 ... 29.53 inch) ¢ 13
751 ... 1 000 mm (29.57 ... 39.37 inch) ¢ 14
1 001 ... 1 250 mm (39.41 ... 49.21 inch) ¢ 15
1 251 ... 1 500 mm (49.25 ... 59.06 inch) ¢ 16
1 501 ... 1 750 mm (59.09 ... 68.90 inch) ¢ 17
1 751 ... 2 000 mm (68.94 ... 78.74 inch) ¢ 18
2 001 ... 2 250 mm (78.78 ... 88.58 inch) ¢ 21
2 251 ... 2 500 mm (88.62 ... 98.43 inch) ¢ 22
2 501 ... 2 750 mm (98.46 ... 108.27 inch) ¢ 23
2 751 ... 3 000 mm (108.31 ... 118.11 inch) ¢ 24
3 001 ... 3 250 mm (118.15 ... 127.95 inch) ¢ 25
3 251 ... 3 500 mm (127.99 ... 137.80 inch) ¢ 26
3 501 ... 3 750 mm (137.83 ... 147.64 inch) ¢ 27
3 751 ... 4 000 mm (147.68 ... 157.48 inch) ¢ 28

4/110 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LVS200, short fork for liquids/ 7ML5732- Further Designs
solids interface
77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order
Vibrating point level switch for solids or solids
within liquid interface applications, and high load code(s).
applications with short insertion requirements Total insertion length: Enter the total insertion length Y01
Stainless steel 316L (1.4404) in plain text description, max. 4 000 mm
(147.48 inch)
Standard length, 165 mm (6.50 inch) 31
Add Order code Y01 and plain text: Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
"Insertion length ... mm" Measuring-point number/identification
(max. 27 characters); specify in plain text
200 ... 500 mm (7.87 ... 19.69 inch) 32
501 ... 750 mm (19.72 ... 29.53 inch) 33 Signal bulb inserted in M20 cable gland1) A20
751 ... 1 000 mm (29.57 ... 39.37 inch) 34 Adjustable sensitivity (by potentiometer) for solids/ G02
1 001 ... 1 250 mm (39.41 ... 49.21 inch) 35 liquids interface detection1)2)
1 251 ... 1 500 mm (49.25 ... 59.06 inch) 36 Operating Instructions Article No.
1 501 ... 1 750 mm (59.09 ... 68.90 inch) 37 Multi-language 7ML1998-5FT63
1 751 ... 2 000 mm (68.94 ... 78.74 inch) 38 This device is shipped with the Siemens Milltronics
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
41
42
manual DVD containing the ATEX Quick Start and
Operating Instructions library. 4
2 501 ... 2 750 mm (98.46 ... 108.27 inch) 43 Spare Parts
2 751 ... 3 000 mm (108.31 ... 118.11 inch) 44 Replacement Electronics Module (350 Hz) 7ML1830-1KM
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
3 001 ... 3 250 mm (118.15 ... 127.95 inch) 45 (SPDT)]
3 251 ... 3 500 mm (127.99 ... 137.80 inch) 46
Sliding sleeve, 2" BSP (ISO 228) 7ML1830-1JM
3 501 ... 3 750 mm (137.83 ... 147.64 inch) 47
3 751 ... 4 000 mm (147.68 ... 157.48 inch) 48 Sliding sleeve, 2" NPT (ASME B1.20.1) 7ML1830-1JN
1) Available with Approval option D only
Material process connection/extension
2)
Stainless steel threads 304 (1.4301), ¢ 1 Available with power supply option 1 only
flanges 321(1.4541), Tri-clamp 304 (1.4301)4)
Stainless steel 316L (1.4404)5) 2
Approvals
CSA/FM Dust Ignition Proof, RCM ¢ A
ATEX II 1/2 D, RCM ¢ B
CSA/FM General Purpose, RCM ¢ C
CE, RCM ¢ D
IEC-Ex t IIIC Da/Db E
1)
Available with Approval option B, D, E only
2)
Not available with extension length options 11,12, 31, 32
3)
Max. 6 bar (87psi)
4)
Available with option extension length 11 ... 28
5)
Available with option extension length 31 … 48

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/111


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LVS200, pipe extension 7ML5733- Further Designs
Vibrating point level switch for high or low levels of
77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order
bulk solids
Extended using 1" pipe extension code(s).
(customer supplied) Total insertion length: Enter the total insertion length Y01
Click on the Article No. for the online configura- in plain text description, max. 3 800 mm
tion in the PIA Life Cycle Portal. (149.61 inch)

Power supply Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
Measuring-point number/identification
19 ... 230 V AC, 19 ... 55 V DC, one relay output 1 (max. 27 characters); specify in plain text
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs 2 Enhanced sensitivity > 5 g/l via electronics and K05
(DPDT)1) increased fork length to 195 mm (7.68 inch)5)
18 ... 50 V DC PNP1) 3 Enhanced sensitivity < 5 g/l via electronics, G01
increased fork length to 195 mm (7.68 inch)
19 ... 230 V AC/DC without contact, 2-wire loop 4 and increased aluminum fork width1)4)5)
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier) 5 Adjustable sensitivity (by potentiometer) for solids/ G02
NAMUR IEC 60947-5-6, 2-wire2) liquids interface detection2)3)4)
4 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3) 6 Signal bulb inserted in M20 cable gland2) A20
Process temperature Operating Instructions Article No.
Up to 150 °C (302 °F) A Multi-language 7ML1998-5FT63
Process connection This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Threaded Operating Instructions library.
R 1½" [(BSPT), EN 10226] A Spare Parts
1½" NPT [(Taper), ANSI/ASME B1.20.1] B
Replacement Electronics Module (125 Hz) 7ML1830-1KL
Flanged [19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
DN 100 PN 6, EN 1092-1 4) C
DN 100 PN 16, EN 1092-1 D Replacement Electronics Module (350 Hz) 7ML1830-1KM
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
2" ASME 150 lb B16.5 E (SPDT)]
3" ASME 150 lb B16.5 F
Isolated switch amplifier relay output A5E03496569
4" ASME 150 lb B16.5 G KFD2-SR2-Ex1.W
2" Tri-clamp (DN 50) ISO 2852 K
1)
Available only with power supply 1 and Approvals C, D and with
Process connection material Process connection flange C … G
Stainless steel threads 304 (1.4301), 1 2)
Available with approval options D only
flanges 321 (1.4541), Tri-clamp 304 (1.4301) 3)
Available with power supply option 1 only and application type 2
Stainless steel 316L (1.4404) 2 4) Not available with option K05
Extension length 5) Available with Application type 1 only
Customer supplied 1" pipe extension 1
Length: 300 ... 3 800 mm (11.81 ... 149.61 inch)
Application type
Dry bulk solids (125 Hz) 1
Liquids/solids interface (350 Hz) 2
Approvals
CSA/FM Dust Ignition Proof, RCM A
ATEX II 1/2 D, RCM B
CSA/FM General Purpose, RCM C
CE, RCM D
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
1/2D, RCM
IEC-Ex t IIIC Da/Db H
1)
Available with Approval options A, B, C, D, G only
2)
Available with Approval options D, E and F only.
Not available for application type 2 "Liquids/solids interface".
3)
Available with Approval options B, D, G only
4)
Max. 6 bar (87 psi)

4/112 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LVS200, cable extended 7ML5734- SITRANS LVS200, cable extended 7ML5734-
Vibrating point level switch for high or low level Vibrating point level switch for high or low level
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
detection of bulk solids materials detection of bulk solids materials
Click on the Article No. for the online configura- Approvals
tion in the PIA Life Cycle Portal. CSA/FM Dust Ignition Proof, RCM A
Power supply ATEX II 1/2 D, RCM B
19 ... 230 V AC, 19 ... 55 V DC, one relay output 1 CSA/FM General Purpose, RCM C
(SPDT)1) CE, RCM D
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs 2 CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
(DPDT)1) E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
18 ... 50 V DC PNP1) 3 Ex ia IIC, RCM
19 ... 230 V AC/DC without contact, 4 ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
2-wire loop powered1) 1/2D, RCM6)
7 ... 9 V DC (requires NAMUR switch amplifier) 5 IEC-Ex t IIIC Da/Db G
NAMUR IEC 60947-5-6, 2-wire2) 1) Available with Approval options A, B, C, D, G only
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3) 6

4
2) Available with Approval option D, E and F only.
Process temperature Not available for application type 2 "Liquids/solids interface".
Up to 80 °C (176 °F) A 3) Available with Approval option D only
Process connection 4) Max. 6 bar (87 psi)
Threaded 5) Not available with application type option 2
R 1½" [(BSPT), EN 10226] (1.4301/304) A 6) Not available with Power supply option 5
1½" NPT [(Taper), ANSI/ASME B1.20.1] B 7) Cable length is limited to 7 000 mm (275.59 inch).
(1.4301/304)
Flanged Selection and Ordering data Order code
DN 100 PN 6, EN 1092-1 (1.4541/321)4) C Further Designs
DN 100 PN 16, EN 1092-1 (1.4541/321) D
Please add "-Z" to Article No. and specify Order
2" ASME 150 lb B16.5 (1.4541/321) E code(s).
3" ASME 150 lb B16.5 (1.4541/321) F Enter the total insertion length in plain text Y01
4" ASME 150 lb B16.5 (1.4541/321) G description, max. 20 000 mm (787.40 inch)
Extension length Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
750 ... 1 000 mm (29.5 ... 39.4 inch) [max. length 10 Measuring-point number/identification
20 000 mm (787.4 inch), not with Power supply (max. 27 characters); specify in plain text
option 5 (max. 10 000 mm, 393.7 inch)] Enhanced sensitivity > 5 g/l via electronics and K05
Add Order code Y01 and plain text: increased fork length to 195 mm (7.68 inch)
"Insertion length ... mm" Enhanced sensitivity < 5 g/l via electronics and G01
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 11 increased fork length to 195 mm (7.68 inch) and
2 001 ... 3 000 mm (78.78 ... 118.11 inch) 12 increased aluminum fork width1)
3 001 ... 4 000 mm (118.15 ... 157.48 inch) 13 Signal bulb inserted in M20 cable gland2) A20
4 001 ... 5 000 mm (157.52 ... 196.85 inch) 14 Operating Instructions Article No.
5 001 ... 6 000 mm (196.89 ... 236.22 inch) 15
Multi-language 7ML1998-5FT63
6 001 ... 7 000 mm (236.26 ... 275.59 inch) 16 This device is shipped with the Siemens Milltronics
7 001 ... 8 000 mm (275.63 ... 314.96 inch)5) 17 manual DVD containing the ATEX Quick Start and
8 001 ... 9 000 mm (315 ... 354.33 inch)5) 18 Operating Instructions library.
9 001 ... 10 000 mm (354.37 ... 393.70 inch)5) 20 Spare Parts
10 001 ... 11000 mm (393.74 ... 433.07 inch)5)6) 21 Replacement Electronics Module (125 Hz) 7ML1830-1KL
11 001 ... 12 000 mm (433.11 ... 472.44 inch)5)6) 22 [19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
12 001 ... 13 000 mm (472.48 ... 511.81 inch)5)6) 23
Replacement Electronics Module (350 Hz) 7ML1830-1KM
13 001 ... 14 000 mm (511.85 ... 551.18 inch)5)6) 24
[19 ... 230 V AC, 19 ... 55 V DC,
14 001 ... 15 000 mm (551.22 ... 590.55 inch)5)6) 25 one relay output (SPDT)]
15 001 ... 16 000 mm (590.59 ... 629.92 inch)5)6) 26
Isolated switch amplifier relay output A5E03496569
16 001 ... 17 000 mm (629.96 ... 669.29 inch)5)6) 27 KFD2-SR2-Ex1.W
17 001 ... 18 000 mm (669.33 ... 708.66 inch)5)6) 28 1)
Available only with power supply 1 and Approvals C, D and with
18 001 ... 19 000 mm (708.70 ... 748.03 inch)5)6) 30
process connection flange C … G
19 001 ... 20 000 mm (748.07 ... 787.40 inch)5)6) 31 2)
Available with Approval options C and D only
Application type
Dry bulk solids (125 Hz) 1
Liquid/solids interface (350 Hz)7) 2

Siemens FI 01 · 2015 4/113


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200

■ Dimensional drawings
120
A (4.72) A View A-A
Thread length
BSP: 20.5 (0.81)
Tine orientation
NPT: 24 (0.94)
marking

(6.1)
(5.91)

155
150

(2.36)

(2.95)
Threaded bushing

60

75
42 (1.67)
[max. temp. 80 °C
(176 °F)]

700 ... 20 000 (27.56 ... 787)**


Optional sliding
bushing* 60
(2.36)
Customer supplied

195 (7.68)
process flange
165 (6.5): Compact solids/ liquids interface model 42 (1.67)

4 100 (3.94)
230 (9.0): Compact standard version
Standard model

300 ... 4 000


170 (6.69):

Solids/liquids (11.81 ... 157): Customer-specified rigid extension


interface model

Standard model
100 (3.94)

170 (6.69):
Solids/liquids
interface model

Tine
Tine

Notes:
* The clamping screws of the sliding bushing must be tightened to 10 Nm.
** Cable version with liquids/solids interface model option length to 7 000 mm (275.59 inch)
Cable version with NAMUR electronics length to 10 000 mm (393.7 inch) tightened to 10 Nm.
See drawing 23650563 for pipe extended version details. (Pipe is customer supplied.)

SITRANS LVS200, dimensions in mm (inch)

4/114 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Vibrating switches
SITRANS LVS200

■ Schematics
FSH/FSL adjustment
LED Universal voltage (DPDT relay) 3-wire PNP
Sensitivity adjustment
(B=factory setting,
A=decreased sensitivity)

Alarm output
relay
FSL
B

1 2 3 4 5 7 8 9 1 2 3
A
FSH

Load
1 2 3 4 5

PE + - Signal output PE + -

4
L N
AC DC
Terminal 1: L, terminal 2: N Terminal 1: +, terminal 2: -
Protective 19 ... 230 V AC, +10 %, 18 ... 50 V DC, +10 %, 1.5 W
L N 50 ... 60 Hz, 18 VA
earth
19 ... 230 V AC or terminal
+/- 19 ... 55 V DC DC
Terminal 1: +, terminal 2: -
19 ... 55 V DC, +10 %, 2 W

2-wire NAMUR IEC 60947-5-6 8/16 mA or 4 ... 20 mA

1 2 AC 1 2 1 2
Terminal 1: L, terminal 2: N
19 ... 230 V AC, +10 %,
50 ... 60 Hz, 1.5 VA Approx. 7 ... 9 V DC, DC
intrinsically safe terminal 1: +, terminal 2: -
DC (IEC 60947-5-6) 2.5 ... 36 V DC, + 0 %
Terminal 1: +, terminal 2: -
PE + - PE + - PE + -
19 ... 230 V DC, +10 %, 1 W
L N L N L N

SITRANS LVS200 connections

Siemens FI 01 · 2015 4/115


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Rotating point level switch
Input
Measured variable High and low and demand
Output
Output signal
• Alarm output Microswitch 5 A at 250 V AC,
non inductive
Microswitch SPDT contact 4 A at
30 V DC, non-inductive
• Pickup delay Standard (1 rpm model):
approx 1.3 seconds
Optional process applications
(5 rpm model): approx. 0.26 seconds

4
Sensitivity Adjustable via reset force of spring or
geometry of measuring vane
Rated operating conditions

SITRANS LPS200 is a rotary paddle switch for point level and Installation conditions
material detection in bulk solids. • Location Indoor/outdoor
Ambient conditions
■ Benefits • Ambient temperature
• Installation category
-25 ... +60 °C (-13 ... +140 °F)
III
• Proven paddle switch technology for bulk solids • Pollution degree 2
• High integrity mechanical seal Medium conditions Bulk solids
• Optional switch selectable power supply • Temperature
• Unique friction clutch mechanism prevents damage from - Standard -25 ... +80 °C (-13 ... +176 °F)
falling material - Optional -25 ... +600°C (-13 ... +1 112 °F)
• Pressure (vessel)
• Rotatable enclosure for convenient wiring - Standard Max. 0.5 bar g (7.25 psi g)
• Optional paddles for use with low density materials - Optional Max. 10 bar g (145 psi g)
• Small paddle makes for simple installation through existing • Minimum material density
process connection - Standard measuring vane • Can detect down to 100 g/l
(6.25 lb/ft3)
• High temperature model and optional extension kit available - Optional measuring vane • Can detect down to15 g/l
• Optional fail-safe configuration detects loss of rotation (2.19 lb/ft3)
Design
■ Application Material
• Enclosure Epoxy coated aluminum
The paddle switch technology detects full, empty, or demand • Process connection, Stainless steel or aluminum
conditions on materials such as grain, feed, cement, plastic measuring shaft and vane
granulate, and wood chips. The paddle switch can handle bulk Process connection Thread NPT, BSP, and flange options
densities as low as 15 g/l (2.19 lb/ft3) with the optional rectangu- Degree of protection IP65/Type 4/NEMA 4
lar vane or 100 g/l (6.25 lb/ft3) with the standard measuring vane. Conduit entry 2 x M20x1.5 or 2 x ½" NPT
A low revolution geared motor with slip clutch drives a rotating Power supply
measuring vane which senses the presence of material at the • Jumper selectable • 115 V AC, ± 15 %, 50 ... 60 Hz,
mounted level of the LPS200. As material comes into contact 4 VA or 230 V AC, ± 15 %,
50 Hz, 6 VA, or 48 V AC, or 24 V AC
with the rotating paddle, rotation stops, which changes the or 24 V DC, ± 15 %, 2.5 W
microswitch state. When the paddle is no longer covered • Universal voltage (DPDT replay) 24 V DC ± 15 % 50 ... 60 Hz,
by material, rotation resumes and the relay reverts to its normal 22...230 V, ± 10 %, max. 10 VA
condition.
Certificates and approvals • CSA/FM General Purpose
The LPS200 has a rugged design for use in harsh conditions in • CE
the solids industry. The sensitivity of the paddle can be adjusted • CSA/FM Dust Ignition Proof
• ATEX II 1/2 D
for varying material properties like buildup on the vane. • RCM
• IECex
The LPS200 comes in a variety of configurations including com-
pact, extended and cable extension. It is equipped with a stan-
dard vane which is effective in most applications, but can be
configured with a hinged or rectangular vane for increased sen-
sitivity for light materials.
• Key Applications: bulk solids such as grain, feed, cement,
plastic granulate, wood chips

4/116 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Article No. Ord. code
SITRANS LPS200, compact 7ML5725- SITRANS LPS200, compact 7ML5725-
Rotary paddle switch for level and material Rotary paddle switch for level and material
77 7 77 - 777 0 777 77 7 77 - 777 0 777
detection in bulk solids. Compact design for detection in bulk solids. Compact design for
side or top mounted applications. side or top mounted applications.
Click on the Article No. for the online con- Process pressure
figuration in the PIA Life Cycle Portal. Up to 0.5 bar (7.25 psi) }¢ 1
Process temperature Up to 5 bar (72.5 psi) 2
Up to 80 °C (176 °F) ¢ 1 Up to 10 bar (145 psi) 3
Up to 150 °C (302 °F) 2 Process connection material
Up to 250 °C (482 °F) 3 Aluminum7) }¢ 1
Stainless steel, threads 303 (1.4305), }¢ 2
Up to 600 °C (1 112 °F)1)2) 4 flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Up to 80 °C (176 °F) basic version }¢ 5 8)
Stainless steel 316L (1.4404) 3
aluminum3) Extension length
Up to 80 °C (176 °F) basic version stainless }¢ 6 100 mm (3.94 inch)9) ¢ 1
steel 4)

4
150 mm (5.91 inch) }¢ 2
Power supply 200 mm (7.87 inch) ¢ 3
230 V AC, 1 rev/min. }¢ A
230 V AC, 1 rev/min., fail-safe B 250 mm (9.84 inch) ¢ 4
230 V AC, 5 rev/min. ¢ C 300 mm (11.81 inch) ¢ 5
230 V AC, 5 rev/min., fail-safe D Measuring vane
115 V AC, 1 rev/min. }¢ E Boot shaped, 35 x 106 mm (1.38 x 4.17 inch)10) }¢ A
115 V AC, 1 rev/min., fail-safe F Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)10)11) ¢ B
Boot shaped, 28 x 98 mm (1.10 x 3.86 inch) ¢ C
115 V AC, 5 rev/min. ¢ G
Rectangular 50 x 150 mm (1.97 x 5.91 inch)12) ¢ D
115 V AC, 5 rev/min., fail-safe H
Rectangular 50 x 250 mm (1.97 x 9.84 inch)12) ¢ E
48 V AC, 1 rev/min. ¢ J Rectangular 98 x 150 mm (3.86 x 5.91 inch)11)12) ¢ F
24 V AC, 1 rev/min. K
Rectangular 98 x 250 mm (3.86 x 9.84 inch)11)12) ¢ G
24 V DC, 1 rev/min. ¢ L
Rectangular 50 x 98 mm (1.97 x 3.86 inch)12) ¢ H
24 V DC, 1 rev/min., fail-safe M
Approvals
24 V DC, 5 rev/min. ¢ N CSA/FM Dust Ignition Proof, RCM }¢ A
24 V DC, 5 rev/min., fail-safe P ATEX II 1/2 D, RCM }¢ B
Switch selectable 230 V AC/115 V }¢ Q CSA/FM General Purpose , RCM }¢ C
AC/24 V DC CE, RCM }¢ D
multi-voltage, 1 rev/min. IEC Ex ta/tb IIIC E
Switch selectable 230 V AC/115 V ¢ R 1) Available with approval option C and D only, up to 0.5 bar
AC/24 V DC
2) Not available with process connection A,B, D, E and G
multi-voltage, 5 rev/min.
3)
48 V AC, 1 rev/min., fail-safe Z J 1A Only available with the following configurations 7ML5725-5AC11-2AD0 or
48 V AC, 5 rev/min. Z J 1B 7ML5725-5EE11-2AC0
4) Only available with the following configurations 7ML5725-6QC12-2AB0 or
48 V AC, 5 rev/min., fail-safe Z J 1C
7ML5725-6QE12-2AA0
24 V AC, 1 rev/min., fail-safe Z J 1D
5) Available with process pressure 1 and 2 only
24 V AC, 5 rev/min. Z J1E
6) Available with process temperature 1 only
24 V AC, 5 rev/min., fail-safe Z J1F
7)
Universal Voltage, 1 rev/min.13) Z J 2A Available with process connections A ... F only, process pressure option 1
Universal Voltage, 1 rev/min, fail-safe13) Z J 2B and process temperature 1 and 5 only
8) Available with process connection C, F, H … N and Measuring vane A
Universal Voltage, 5 rev/min.13) Z J 2C
9)
Universal Voltage, 5 rev/min, fail-safe13) Z J 2D Available with measuring vane option A, C, D, E, H only
10) Add 16 mm (0.63 inch) to extension length
Process connection
11) Available with extension lengths 2, 3, 4, 5
Threaded
12) Available with process connections H … M only
G 1¼" [(BSPP), EN ISO 228-1] ¢ A
13) Available
G 1" [(BSPP), EN ISO 228-1] ¢ B with approval option B,D, and E only
G 1½" [(BSPP), EN ISO 228-1] }¢ C ¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ D
} Available ex stock. For details see page 9/5 in the appendix.
1¼" NPT [(Taper), ANSI/ASME B1.20.1] }¢ E
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ F
Flanged
DN 32 PN 6, EN 1092-15) G
DN 100 PN 6, EN 1092-15) H
DN 100 PN 16, EN 1092-1 J
2" ASME 150 lb B16.5 K
3" ASME 150 lb B16.5 L
4" ASME 150 lb B16.5 M
2" Tri-clamp (DN 50) ISO28526) N

Siemens FI 01 · 2015 4/117


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Order code Selection and Ordering data Order code
Further Designs Available ex stock
Please add "-Z" to Article No. and specify Order For details see page 9/5 in the appendix.
code(s).
SITRANS LPS200, compact for up to 7ML1830-1KG
Heating of enclosure1)2) A35 80 °C (176 °F), aluminum, with power supply A,
Signal bulb inserted in M20 cable gland1) A20 process connection C, process pressure 1,
Food grade materials (in contact with process), K01 process connection material 1, extension length 2,
according to 1935/2004/EC, with FDA conform measuring vane A, and approval D
shaft sealing3) SITRANS LPS200, compact for up to 80 °C 7ML5725-
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14 (176 °F), aluminum, with power supply E, 5EE11-2AC0
Measuring-point number/identification process connection E, process pressure 1,
(max. 27 characters); specify in plain text process connection material 1, extension length 2,
measuring vane A, and approval C
Additional Operating Instructions Article No.
SITRANS LPS200, compact for up to 80 °C 7ML5725-
Multi-language 7ML1998-5FS62 (176 °F), stainless steel, with power supply Q, 6QC12-2AB0
This device is shipped with the Siemens Milltronics process connection C, process pressure 1,
manual DVD containing the ATEX Quick Start and process connection material 2, extension length 2,

4
Operating Instructions library. measuring vane A, and approval B
Spare Parts SITRANS LPS200, compact for up to 80 °C 7ML5725-
Motor gear /PLC, multi-voltage 7ML1830-1KG (176 °F), stainless steel, with power supply Q, 6QE12-2AA0
process connection E, process pressure 1,
Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH process connection material 2, extension length 2,
(1.38 x 4.17 inch) measuring vane A, and approval A
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch) 7ML1830-1KJ 1) Available with approval option D only
2) Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
Rigid extension kit
J2A, J2C only
(includes spring coupling, rigid tube extension and 3)
required pins) Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design.
Extension: 500, 400, 300 mm (19.7, 15.8, 11.8 inch) 7ML5711-0AA
Extension: 1 000, 900, 800, 700, 600 mm 7ML5711-1AA
(39.4, 35.4, 31.5, 27.6, 23.6 inch)
Extension: 1 500, 1 400, 1 300, 1 200, 1 100 mm 7ML5711-2AA
(59.1, 55.1, 51.2, 47.2, 43.3 inch)

4/118 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Article No. Ord. code
SITRANS LPS200, shaft protected 7ML5726- SITRANS LPS200, shaft protected 7ML5726-
Rotary paddle switch for level and material Rotary paddle switch for level and material
77 7 77 - 7777 777 77 7 77 - 7777 777
detection in bulk solids; ideal for heavy, detection in bulk solids; ideal for heavy,
sticky, or high impact applications. sticky, or high impact applications.
Designed with added protection tube for Designed with added protection tube for
enhanced shaft protection and protection enhanced shaft protection and protection
against build-up on shaft (sidewall build-up). against build-up on shaft (sidewall build-up).
Click on the Article No. for the online confi- Process pressure
guration in the PIA Life Cycle Portal. Up to 0.5 bar (7.25 psi) }¢ 1
Process temperature Up to 5 bar (72.5 psi) 2
Up to 80 °C (176 °F) ¢ 1 Up to 10 bar (145 psi) 3
Up to 150 °C (302 °F) 2 Process connection material
Up to 250 °C (482 °F) 3 Aluminum6) ¢ 1
Stainless steel, threads 303 (1.4305), }¢ 2
Up to 600 °C (1 112 °F)1)2) 4 flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Up to 80 °C (176 °F) basic version3) } 5 Stainless steel 316L (1.4404) 7) 3

Power supply
230 V AC, 1 rev/min. ¢ A
Extension length
150 mm (5.91 inch)8) ¢ 1 4
200 mm (7.87 inch) }¢ 2
230 V AC, 1 rev/min., fail-safe B
230 V AC, 5 rev/min. ¢ C 250 mm (9.84 inch) ¢ 3
300 mm (11.81 inch) ¢ 4
230 V AC, 5 rev/min., fail-safe D
115 V AC, 1 rev/min. ¢ E Extension material (protection tube)
Aluminum9) ¢ A
115 V AC, 1 rev/min., fail-safe F
Stainless steel 303 (1.4305) }¢ B
115 V AC, 5 rev/min. ¢ G
Stainless steel 316L (1.4404)10) C
115 V AC, 5 rev/min., fail-safe H
48 V AC, 1 rev/min. ¢ J Measuring vane
Boot shaped 35 x 106 mm }¢ A
24 V AC, 1 rev/min. ¢ K (1.38 x 4.17 inch)11)
24 V DC, 1 rev/min. ¢ L Hinged vane 65 x 200 mm ¢ B
24 V DC, 1 rev/min., fail-safe M (2.56 x 7.87 inch)11)12)
Rectangular 50 x 150 mm ¢ D
24 V DC, 5 rev/min. ¢ N (1.97 x 5.91 inch)13)
24 V DC, 5 rev/min., fail-safe P Rectangular 50 x 250 mm ¢ E
Switch selectable 230 V AC/115 V AC/ }¢ Q (1.97 x 9.84 inch)13)
24 V DC Rectangular 98 x 150 mm ¢ F
multi-voltage, 1 rev/min. (3.86 x 5.91 inch)12)13)
Switch selectable 230 V AC/115 V AC/ ¢ R Rectangular 98 x 250 mm ¢ G
24 V DC (3.86 x 9.84 inch)12)13)
multi-voltage, 5 rev/min. Rectangular 50 x 98 mm ¢ H
48 V AC, 1 rev/min., fail-safe Z J 1A (1.97 x 3.86 inch)13)
48 V AC, 5 rev/min. Z J 1B Approvals
48 V AC, 5 rev/min., fail-safe Z J 1C CSA/FM Dust Ignition Proof, RCM }¢ 1
24 V AC, 1 rev/min., fail-safe Z J 1D ATEX II 1/2 D, RCM }¢ 2
24 V AC, 5 rev/min. Z J1E CSA/FM General Purpose, RCM ¢ 3
CE, RCM ¢ 4
24 V AC, 5 rev/min., fail-safe Z J1F IEC Ex ta/tb IIIC 5
Universal Voltage, 1 rev/min.14) Z J 2A
1) Available with approval option 3 and 4 only and up to max 0.5 bar
Universal Voltage, 1 rev/min, fail-safe14) Z J 2B 2) Not available with process connections A, C, E
Universal Voltage, 5 rev/min.14) Z J 2C
3) Only available with the following configurations 7ML5726-5QB12-2BA2 or
Universal Voltage, 5 rev/min, fail-safe14) Z J 2D 7ML5726-5QC12-2BA1
4)
Process connection Available with process pressure 1 and 2 only
Threaded 5) Available with process temperature 1 only
G 1¼" [(BSPP), EN ISO 228-1] ¢ A 6) Available with process connections A ... E only, available with process
pressure option 1 only, and process temperature 1 only
G 1½" [(BSPP), EN ISO 228-1] }¢ B
7) Extension and vane will also change to 316L, only for process connection
1¼" NPT [(Taper), ANSI/ASME B1.20.1] }¢ C
B, D, F …L and vane A
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ D 8) Available with measuring vane options A, D, E, H only
Flanged 9) Available with process pressure 1 and process temperature 1 only
10) Available
DN 32 PN 6, EN 1092-14) E with process connections B, D, F … L and vane A
11)
DN 100 PN 6, EN 1092-14) F Add 16 mm (0.63 inch) to extension length
12)
DN 100 PN 16, EN 1092-1 G Available with extension length options 2 … 4 only
13)
Available with process connections F, G, H, J, K only
2" ASME 150 lb B16.5 H 14)
Available with approval options 2, 4 and 5 only
3" ASME 150 lb B16.5 J
4" ASME 150 lb B16.5 K ¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
2" Tri-clamp (DN 50) ISO28525) L } Available ex stock. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/119


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Order code Selection and Ordering data Article No. Ord. code
Further Designs SITRANS LPS200, cable extension 7ML5727-
Please add "-Z" to Article No. and specify Order Rotary paddle switch for level and material
detection in bulk solids. 77777 - 777 777
code(s).
Cable extension for increased length in
Heating of enclosure1)2) A35 top-mounted applications
Signal bulb inserted in M20 cable gland1) A20 Click on the Article No. for the online con-
Food grade materials (in contact with process), K01 figuration in the PIA Life Cycle Portal.
according to 1935/2004/EC, with FDA conform Process temperature
shaft sealing3)
Up to 80 °C (176 °F) ¢ 1
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
Measuring-point number/identification Up to 150 °C (302 °F) 2
(max. 27 characters); specify in plain text Up to 250 °C (482 °F) 3
Additional Operating Instructions Article No. Up to 600 °C (1 112 °F)1)2) 4
Multi-language 7ML1998-5FS62 Up to 80 °C (176 °F) basic version3) 5
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and Power supply
Operating Instructions library. 230 V AC, 1 rev/min. ¢ A
4 Spare Parts 230 V AC, 1 rev/min., fail-safe B
Motor gear /PLC, multi-voltage 7ML1830-1KG 230 V AC, 5 rev/min. ¢ C
Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17 inch) 230 V AC, 5 rev/min., fail-safe D
115 V AC, 1 rev/min. ¢ E
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch) 7ML1830-1KJ
115 V AC, 1 rev/min., fail-safe F
Available ex stock
For details see page 9/5 in the appendix. 115 V AC, 5 rev/min. ¢ G
115 V AC, 5 rev/min., fail-safe H
SITRANS LPS200, extended for up to 80 °C 7ML5726-
(176 °F), power supply Q, process connection B, 5QB12-2BA2 48 V AC, 1 rev/min. ¢ J
process pressure 1, process connection material 2,
extension length 2, extension material B, 24 V AC, 1 rev/min. K
measuring vane A, and approval 2 24 V DC, 1 rev/min. ¢ L
SITRANS LPS200, extended for up to 80 °C 7ML5726- 24 V DC, 1 rev/min., fail-safe M
(176 °F), power supply Q, process connection C, 5QC12-2BA1
24 V DC, 5 rev/min. ¢ N
process pressure 1, process connection material 2,
extension length 2, extension material B, 24 V DC, 5 rev/min., fail-safe P
measuring vane A, and approval 1 Switch selectable 230 V AC/115 V AC/ ¢ Q
1)
Available with approval option 4 only 24 V DC multi-voltage, 1 rev/min.
2) Switch selectable 230 V AC/115 V AC/ ¢ R
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
J2A, J2C only
24 V DC multi-voltage, 5 rev/min.
3) 48 V AC, 1 rev/min., fail-safe Z J1A
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design. 48 V AC, 5 rev/min. Z J1B
48 V AC, 5 rev/min., fail-safe Z J1C
24 V AC, 1 rev/min., fail-safe Z J1D
24 V AC, 5 rev/min. Z J1E
24 V AC, 5 rev/min., fail-safe Z J1F
Universal Voltage, 1 rev/min.9) Z J2A
Universal Voltage, 1 rev/min, fail-safe9) Z J2B
Universal Voltage, 5 rev/min.9) Z J2C
Universal Voltage, 5 rev/min, fail-safe9) Z J2D
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1] ¢ A
G 1½" [(BSPP), EN ISO 228-1] ¢ B
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ C
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ D
Flanged
DN 32 PN 6, EN 1092-14) E
DN 100 PN 6, EN 1092-14) F
DN 100 PN 16, EN 1092-1 G
2" ASME 150 lb B16.5 H
3" ASME 150 lb B16.5 J
4" ASME 150 lb B16.5 K

4/120 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Order code
SITRANS LPS200, cable extension 7ML5727- Further Designs
Rotary paddle switch for level and material
detection in bulk solids. 77777 - 777 777 Please add "-Z" to Article No. and specify Order
Cable extension for increased length in code(s).
top-mounted applications Total insertion length: Y01
Process pressure Enter the total insertion length in plain text
Up to 0.5 bar (7.25 psi) ¢ 1 description, max. 10 000 mm (393.70 inch)
Up to 5 bar (72.5 psi) 2 Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
Up to 10 bar (145 psi) 3 Measuring-point number/identification
(max. 27 characters); specify in plain text
Process connection material
Reinforced cable (max. 28 kN pulling force)1) P01
Aluminum5) ¢ 1
Stainless steel, threads 303 (1.4305), ¢ 2 Heating of enclosure2)3) A35
flanges 321 (1.4541) Signal bulb inserted in M20 cable gland2) A20
Cable extension length Food grade materials (in contact with process), K01
Standard cable length, 2 000 mm ¢ 0 according to 1935/2004/EC, with FDA conform
(78.74 inch) shaft sealing4)
Add Order code Y01 and plain text:
"Insertion length ... mm"
Additional Operating Instructions Article No. 4
Multi-language 7ML1998-5FS62
500 ... 1 000 mm (19.69 ... 39.37 inch) ¢ 1
This device is shipped with the Siemens Milltronics
Cable length 1 001 ... 2 000 mm ¢ 2 manual DVD containing the ATEX Quick Start and
(39.41 ... 78.74 inch) Operating Instructions library.
Cable length 2 001 ... 3 000 mm ¢ 3
(78.78 ... 118.11 inch) Spare Parts
Cable length 3 001 ... 4 000 mm ¢ 4 Motor gear /PLC, multi-voltage 7ML1830-1KG
(118.15 ... 157.48 inch)
Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
Cable length 4 001 ... 5 000 mm ¢ 5 (1.38 x 4.17 inch)
(157.52 ... 196.85 inch)
Cable length 5 001 ... 6 000 mm ¢ 6 Hinged vane, 65 x 200 mm (2.56 x 7.87 inch) 7ML1830-1KJ
(196.89 ... 236.22 inch) Rope extension kit, 2 m (6.56 ft) 7ML1830-1KK
Cable length 6 001 ... 7 000 mm ¢ 7
(236.26 ... 275.59 inch) Available ex stock
Cable length 7 001 ... 10 000 mm ¢ 8 For details see page 9/5 in the appendix.
(275.63 ... 393.70 inch) SITRANS LPS200, cable extension for up to 80 °C 7ML5727-
Without extension8) 9 N1A (176 °F), power supply Q, process connection B, 5QB12-0AB0
process pressure 1, process connection material 2,
Measuring vane extension length 0, measuring vane A,
Boot shaped, 35 x 106 mm ¢ A and approval B
(1.38 x 4.17 inch)6)
SITRANS LPS200, cable extension for up to 80 °C 7ML5727-
Hinged vane, 65 x 200 mm ¢ B (176 °F), power supply Q, process connection C, 5QC12-0AA0
(2.56 x 7.87 inch)6) process pressure 1, process connection material 2,
Boot shaped, 28 x 98 mm ¢ C extension length 0, measuring vane A,
(1.10 x 3.86 inch)7) and approval A
Rectangular 50 x 150 mm ¢ D 1)
(1.97 x 5.91 inch)7) Available only for process temperature up to 80 °C (176 °F) and process
connection material 2
Rectangular 50 x 250 mm ¢ E 2)
(1.97 x 9.84 inch)7) Available with approval option D only
3)
Rectangular 98 x 150 mm ¢ F Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
(3.86 x 5.91 inch)7) J2A, J2C only
4)
Rectangular 50 x 98 mm ¢ G Available up to 250 °C (482 °F). This option does not automatically
(1.97 x 3.86 inch)7) implement a food conform design
Approvals
CSA/FM Dust Ignition Proof, RCM ¢ A
ATEX II 1/2 D, RCM ¢ B
CSA/FM General Purpose, RCM ¢ C
CE, RCM ¢ D
IEC Ex ta/tb IIIC E
1) Available with approval option C and D up to max. 0.5 bar
2) Not available with process connections A, C, E
3) Only available with the following configurations 7ML5727-5QC12-0AA0 or
7ML5727-5QB12-0AB0
4) Available with process pressure 1 and 2 only
5) Available with process connections A ... E only, process pressure option 1
only and process temperature options 1 and 5 only
6)
Add 16 mm (0.63 inch) to extension length
7)
Available with process connections F … K only
8)
Not available with P01 and available with Approval D, mounting kit for rope
extension included
9)
Available with approval options B,D, and E only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/121


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Article No. Ord. code
SITRANS LPS200, angled extension 7ML5728- SITRANS LPS200, angled extension 7ML5728-
Rotary paddle switch with robust design for 7 7 7 77 - 77 7 0 777
Rotary paddle switch with robust design for 7 7 7 77 - 77 7 0 777
level and material detection in bulk solids; level and material detection in bulk solids;
ideal for heavy or sticky applications. ideal for heavy or sticky applications.
Angled extension is designed to avoid falling Angled extension is designed to avoid falling
material and rotates horizontally in side mount material and rotates horizontally in side mount
applications to continue working even with applications to continue working even with
heavy build-up. heavy build-up.
Click on the Article No. for the online confi- Measuring vane
guration in the PIA Life Cycle Portal. Rectangular vane, 50 x 98 mm A
Process temperature (1.97 x 3.86 inch)
Up to 80 °C (176 °F) 1 Rectangular vane, 50 x 150 mm B
(1.97 x 5.91 inch)
Up to 150 °C (302 °F) 2
Rectangular vane, 50 x 250 mm C
Up to 250 °C (482 °F) 3
(1.97 x 9.84 inch)
Power supply
Rectangular vane 98 x 150 mm D
230 V AC, 1 rev/min. A (3.86 x 5.91 inch)
230 V AC, 1 rev/min., fail-safe B
4
Rectangular vane 98 x 250 mm E
230 V AC, 5 rev/min. C (3.86 x 9.84 inch)
230 V AC, 5 rev/min., fail-safe D Hinged vane, 65 x 200 mm F
115 V AC, 1 rev/min. E (2.56 x 7.87 inch)
115 V AC, 1 rev/min., fail-safe F
Approvals
115 V AC, 5 rev/min. G CSA/FM Dust Ignition Proof, RCM A
115 V AC, 5 rev/min., fail-safe H ATEX II 1/2 D, RCM B
48 V AC, 1 rev/min. J CSA/FM General Purpose, RCM C
24 V AC, 1 rev/min. K CE, RCM D
24 V DC, 1 rev/min. L IEC Ex ta/tb IIIC E
24 V DC, 1 rev/min., fail-safe M 1) Available with process pressure 1 and 2 only
24 V DC, 5 rev/min. N 2) Available with approval option B,D, and E only
24 V DC, 5 rev/min., fail-safe P
Switch selectable 230 V AC/115 V AC/24 V DC Q
multi-voltage, 1 rev/min. Selection and Ordering data Order code
Switch selectable 230 V AC/115 V AC/24 V DC R Further Designs
multi-voltage, 5 rev/min. Please add "-Z" to Article No. and specify Order
48 V AC, 1 rev/min., fail-safe Z J 1A code(s).
48 V AC, 5 rev/min. Z J 1B Heating of enclosure1)2) A35
48 V AC, 5 rev/min., fail-safe Z J 1C Signal bulb inserted in M20 cable gland1) A20
24 V AC, 1 rev/min., fail-safe Z J 1D Food grade materials (in contact with process), K01
24 V AC, 5 rev/min. Z J1E according to 1935/2004/EC, with FDA conform
shaft sealing3)
24 V AC, 5 rev/min., fail-safe Z J1F
Stainless steel tag [100 x 45 mm Y14
Universal Voltage, 1 rev/min.2) Z J 2A (3.94 x 1.77 inch)]: Measuring-point number/
Universal Voltage, 1 rev/min, fail-safe2) Z J 2B identification (max. 27 characters); specify in
plain text
Universal Voltage, 5 rev/min.2) Z J 2C Additional Operating Instructions Article No.
Universal Voltage, 5 rev/min, fail-safe2) Z J 2D
Multi-language 7ML1998-5FS62
Process connection This device is shipped with the Siemens Mill-
Flanged tronics manual DVD containing the ATEX Quick
DN 100 PN 6, EN 1092-11) A Start and Operating Instructions library.
DN 100 PN 16, EN 1092-1 B Spare Parts
4" ASME 150 lb B16.5 C
Motor gear /PLC, multi-voltage 7ML1830-1KG
Process pressure
Up to 0.5 bar (7.25 psi) 1 Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17 inch)
Up to 5 bar (72.5 psi) 2
Up to 10 bar (145 psi) 3 Hinged vane, 65 x 200 mm (2.56 x 7.87 inch) 7ML1830-1KJ
Process connection material 1)
Available with approval option D only
Stainless steel 303/321 (1.4305/1.4541) 1 2)
Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D, J1E,
Extension length J2A, J2C only
125 mm (4.92 inch) 1 3)
This option does not automatically implement a food conform design
150 mm (5.91 inch) 2
200 mm (7.87 inch) 3
250 mm (9.84 inch) 4
300 mm (11.81 inch) 5

4/122 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Article No. Ord. code
SITRANS LPS200, rigid extension 7ML5730- SITRANS LPS200, rigid extension 7ML5730-
Rotary paddle switch for top mount point level Rotary paddle switch for top mount point level
and material detection in bulk solids 77777 - 7777 777 and material detection in bulk solids 77777 - 7777 777

Click on the Article No. for the online configu- Process pressure
ration in the PIA Life Cycle Portal. Up to 0.5 bar (7.25 psi) ¢ 1
Process temperature Up to 5 bar (72.5 psi) 2
Up to 80 °C (176 °F) ¢ 1 Up to 10 bar (145 psi) 3
Up to 150 °C (302 °F) 2 Process connection material
Up to 250 °C (482 °F) 3 Aluminum5) ¢ 1
Up to 600 °C (1 112 °F)1)2) 4 Stainless steel, threads 303 (1.4305), ¢ 2
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Power supply Stainless steel 316L (1.4404)6) 3
230 V AC, 1 rev/min. ¢ A
230 V AC, 1 rev/min., fail-safe B Extension material (protection tube)
230 V AC, 5 rev/min. ¢ C Aluminum7)8) ¢ 0
Stainless steel 303 (1.4305)9) ¢ 1
230 V AC, 5 rev/min., fail-safe D Stainless steel 316L (1.4404)10)11) 2
115 V AC, 1 rev/min. ¢ E
115 V AC, 1 rev/min., fail-safe
115 V AC, 5 rev/min. ¢
F
G
Extension length
Aluminum 4
250 ... 500 mm (9.84 ... 19.69 inch) ¢ A
115 V AC, 5 rev/min., fail-safe H 501 ... 750 mm (19.72 ... 29.53 inch) ¢ B
48 V AC, 1 rev/min. ¢ J 751 ... 1 000 mm (29.57 ... 39.37 inch) ¢ C
24 V AC, 1 rev/min. ¢ K
¢ L 1 001 ... 1 250 mm (39.41 ... 42.21 inch) ¢ D
24 V DC, 1 rev/min. 1 251 ... 1 500 mm (49.25 ... 59.06 inch) ¢ E
24 V DC, 1 rev/min., fail-safe M 1 501 ... 1 750 mm (59.09 ... 68.90 inch) ¢ F
24 V DC, 5 rev/min. ¢ N 1 751 ... 2 000 mm (68.94 ... 78.74 inch) ¢ G
24 V DC, 5 rev/min., fail-safe P 2 001 ... 2 250 mm (78.78 ... 88.58 inch) ¢ H
Switch selectable 230 V AC/115 V AC/24 V DC ¢ Q 2 251 ... 2 500 mm (88.62 ... 98.43 inch) ¢ J
multi-voltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC ¢ R 2 501 ... 2 750 mm (98.46 ... 108.27 inch) ¢ K
multi-voltage, 5 rev/min. 2 751 ... 3 000 mm (108.31 ... 118.11 inch) ¢ L
48 V AC, 1 rev/min., fail-safe Z J 1A 3 001 ... 3 250 mm (118.15 ... 127.95 inch) ¢ M
48 V AC, 5 rev/min. Z J 1B 3 251 ... 3 500 mm (127.99 ... 137.80 inch) ¢ N
48 V AC, 5 rev/min., fail-safe Z J 1C 3 501 ... 3 750 mm (137.83 ... 147.64 inch) ¢ P
24 V AC, 1 rev/min., fail-safe Z J 1D 3 751 ... 4 000 mm (147.67 ... 157.48 inch) ¢ Q
24 V AC, 5 rev/min. Z J 1E Stainless steel 303 (1.4305)
24 V AC, 5 rev/min., fail-safe Z J1F 250 ... 500 mm (9.84 ... 19.69 inch) ¢ R
Universal Voltage, 1 rev/min.14) Z J 2A 501 ... 750 mm (19.72 ... 29.53 inch) ¢ S
751 ... 1 000 mm (29.57 ... 39.37 inch) ¢ T
Universal Voltage, 1 rev/min, fail-safe14) Z J 2B
Universal Voltage, 5 rev/min.14) Z J 2C 1 001 ... 1 500 mm (39.41 ... 59.05 inch) ¢ U
Universal Voltage, 5 rev/min, fail-safe14) Z J 2D 1 501 ... 2 000 mm (59.09 ... 78.74 inch) ¢ V
2 001 ... 2 500 mm (78.78 ... 98.42 inch) ¢ W
Process connection
Threaded 2 501 ... 3 000 mm (98.46 ... 118.11 inch) ¢ X
G 1¼" [(BSPP), EN ISO 228-1] ¢ A 3 001 ... 4 000 mm (118.15 ... 157.48 inch) ¢ Y
G 1½" [(BSPP), EN ISO 228-1] ¢ B Stainless steel 316L (1.4404)
1¼" NPT [(Taper), ANSI/ASME B1.20.1] ¢ C 250 ... 500 mm (9.84 ... 19.69 inch) Z P 1A
1½" NPT [(Taper), ANSI/ASME B1.20.1] ¢ D 501 ... 750 mm (19.72 ... 29.53 inch) Z P 1B
Flanged 751 ... 1 000 mm (29.57 ... 39.37 inch) Z P 1C
Z P 1D
DN 32 PN 6, EN 1092-13) E 1 001 ... 1 500 mm (39.41 ... 59.05 inch)
DN 100 PN 6, EN 1092-13) F 1 501 ... 2 000 mm (59.09 ... 78.74 inch) Z P1E
DN 100 PN 16, EN 1092-1 G 2 001 ... 2 500 mm (78.78 ... 98.42 inch) Z P1F
2 501 ... 3 000 mm (98.46 ... 118.11 inch) Z P 1G
2" ASME 150 lb B16.5 H
3" ASME 150 lb B16.5 J 3 001 ... 4 000 mm (118.5 ... 157.48 inch) Z P 1H
4" ASME 150 lb B16.5 K
2" Tri-clamp 2’ (DN 50) ISO28524) L

Siemens FI 01 · 2015 4/123


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200
Selection and Ordering data Article No. Ord. code Selection and Ordering data Order code
SITRANS LPS200, rigid extension 7ML5730- Further Designs
Rotary paddle switch for top mount point level Please add "-Z" to Article No. and specify Order
and material detection in bulk solids 77777 - 7777 777
code(s).
Measuring vane
Total insertion length: Enter the total insertion length Y01
Boot shaped, 35 x 106 mm (1.34 x 4.17 inch)12) ¢ A in plain text description, max. 4 000 mm
Hinged vane, 60 x 200 mm (2.36 x 7.87 inch)12) ¢ B (157.48 inch)
Rectangular 50 x 150 mm (1.97 x 5.91 inch)13) ¢ C
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Y14
Rectangular 50 x 250 mm (1.97 x 9.84 inch)13) ¢ D Measuring-point number/identification
Rectangular 98 x 150 mm (3.86 x 5.91 inch)13) ¢ E (max. 27 characters); specify in plain text
Rectangular 98 x 250 mm (3.86 x 9.84 inch)13) ¢ F Heating of enclosure1)2) A35
Rectangular 50 x 98 mm (1.97 x 3.86 inch)13) ¢ G
Signal bulb inserted in M20 cable gland1) A20
Approvals
CSA/FM Dust Ignition Proof, RCM ¢ 1 Food grade materials (in contact with process), K01
ATEX II 1/2 D, RCM ¢ 2 according to 1935/2004/EC, with FDA conform
CSA/FM General Purpose, RCM ¢ 3 shaft sealing3)4)
CE, RCM ¢ 4 Seal at tube end for ingress protection and

4
IEC Ex ta/tb IIIC 5 shaft stability
1) Available with approval option 3 and 4, up to max 0.5 bar Max. temperature 80 °C (176 °F) P06
2) Not available with process connection A, C, E Max. temperature 150 °C (302 °F) P07
3) Available with process pressure 1 and 2 only Max. temperature 250 °C (482 °F) P08
4) Available with process temperature 1 only
5) Max. temperature 600 °C (1 112 °F) P09
Available with process connections A ... E only, with process pressure
option 1 only and process temperature 1 only Sliding sleeve (standard, max. pressure 0.5 bar)1)5) P12
6) Available with process connection B, D, F … L and measuring vane Sliding sleeve (pressure tight, for over-pressure P13
option A application starting from 1 bar max., dependent on
7) Available with process pressure 1 and process temperature 1 only pressure option ordered)6)
8) Available with extension length options A … Q only Additional Operating Instructions Article No.
9) Available with extension length options R … Y only
10) Available
Multi-language 7ML1998-5FS62
with process connection B, D, F …L and measuring vane A, This device is shipped with the Siemens Milltronics
process connection material 3. Available only with extension length options manual DVD containing the ATEX Quick Start and
P1A … P1H only Operating Instructions library.
11) Only available with seal at tube end, option P06 … P09
12) Add
Spare Parts
16 mm (0.63 inch) to extension length
13) Available with process connections F, G, H, J, K only
Motor gear/PLC, multi-voltage 7ML1830-1KG
14) Available with approval options 2, 4 and 5 only Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17 inch)
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix Hinged vane, 65 x 200 mm (2.56 x 7.87 inch) 7ML1830-1KJ
1)
Available with approval option 4 only
2)
15) Available with power supply options A ,C, E, G, J, K, L, N, J1B, J1D,
J1E, J2A, J2C only
3)
Available when ordered with ingress protection seal P06 … P09 only
4)
Available up to 250 °C (482 °F). This option does not automatically
implement a food conform design
5)
Available with process pressure 1 only
6)
Available up to 250 °C (482 °F)

4/124 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200

■ Dimensional drawings
Standard model: compact version High temperature model: compact version
Conduit connection
M20 or ½" NPT 60 (2.36) Thread length Process A
BSP: 20.5 (0.81) temperature
NPT: 24 (0.94) 150/250 °C 200
(302/482 ºF) (7.87)
600 °C 400

A
60 (2.36) Ambient temperature
(1 112 ºF) (15.74)
-25 ... +60 °C
75 (2.95)
(-13 ... +140 °F)

120 (4.72) Zone 21


Ambient temperature (Cat. 2)
-25 ... +60 °C L= Length
(-13 ... +140 °F) (4.84) Zone 20 100 (3.94)
(Cat. 1) 150 (5.91)
123

4
Zone 21
Process temperature 2)

1)
(Cat. 2) 200 (7.87)

L
-25 ... +600 °C 250 (9.84)
Zone 20 (-13 ... +428 °F)
(Cat. 1) 300 (11.81)
Process temperature Optional
1)

process
L

-25 ... +80 °C


flange Shaft protected
(-13 ... +176 °F) Angle option Rope option
option
Thread length
BSP: 20.5 (0.81)

total length available 10 000 (393.7)


Rope

Can be shortened by the customer;


NPT: 24 (0.94) Measuring vane
fixing

(4.92 ... 8.46)


125 ... 300

2 000 (78.74) standard;


1)
L

Measuring vanes

Standard Hinged

106
(2.56)

(4.17) Fold
65

together
to lead
Min. 37
35 (1.38)

into 210 (8.27)


mounting (1.46)
hole
Completely covered Covered up to 10 cm (3.93 inch)
with material with material
Rectangular Rectangular vane options Vane
Spring adjustment Spring adjustment
A B Central Central
Light Light
50 (1.97) 98 (3.86) (factory setting) (factory setting)
boot shaped 200 g/l 300 g/l 100 g/l 150 g/l
A

50 (1.97) 150 (5.90) 35 x 106 mm (12.5 lb/ft³) (18.7 lb/ft³) (6.2 lb/ft³) (9.4 lb/ft³)
50 (1.97) 250 (9.84) boot shaped 300 g/l 500 g/l 150 g/l 150 g/l
B 28 x 98 mm (18.7 lb/ft³) (31.2 lb/ft³) (9.4 lb/ft³) (9.4 lb/ft³)
98 (3.86) 150 (5.90)
rectangular 300 g/l 500 g/l 150 g/l 250 g/l
98 (3.86) 250 (9.84) 50 x 98 mm (18.7 lb/ft³) (31.2 lb/ft³) (9.4 lb/ft³) (15.6 lb/ft³)
rectangular 80 g/l 120 g/l 40 g/l 60 g/l
1. For 35 x 106 mm boot shaped and 65 x 210 mm hinged 50 x 150 mm (5.0 lb/ft³) (7.5 lb/ft³) (2.5 lb/ft³) (3.7 lb/ft³)
measuring vanes, add 16 mm to extension length. rectangular 30 g/l 50 g/l 15 g/l 25 g/l
50 x 250 mm (1.9 lb/ft³) (3.1 lb/ft³) (0.9 lb/ft³) (1.6 lb/ft³)
2. For use with all approval options except CSA class II. See
rectangular 30 g/l 50 g/l 15 g/l 25 g/l
manual for more details. 98 x 150 mm (1.9 lb/ft³) (3.1 lb/ft³) (0.9 lb/ft³) (1.6 lb/ft³)
Notes rectangular 20 g/l 30 g/l 15 g/l 15 g/l
98 x 250 mm (1.2 lb/ft³) (1.9 lb/ft³) (0.9 lb/ft³) (0.9 lb/ft³)
For heavy material, only top mounting of paddle switch is
hinged 70 g/l 100 g/l 35 g/l 50 g/l
recommended. 65 x 210 mm (4.4 lb/ft³) (6.2 lb/ft³) (2.2 lb/ft³) (3.1 lb/ft³)
Compact LPS200 is recommended for side mounting on bins hinged 70 g/l 100 g/l 35 g/l 50 g/l
for low or intermediate material levels. 60 x 200 mm (4.4 lb/ft³) (6.2 lb/ft³) (2.2 lb/ft³) (3.1 lb/ft³)

SITRANS LPS200, dimensions in mm (inch)

Siemens FI 01 · 2015 4/125


© Siemens AG 2014

Level Measurement
Point level measurement – Rotation paddle switches
SITRANS LPS200

■ Schematics
AC or DC version, SPDT, fail-safe

Switching and timing behaviour:


If the vane is not covered, the rotating vane
shaft will send pulses at 20 second intervals.
In case of fault, the pulses are missed. After
30 seconds, the alarm relay will open.
8 7 6 5 1 2

24 V or 48 V or 115 V or 230 V AC, 50/60 Hz, 5 VA


L N PE OR
Alarm Signal + -
24 V DC, 2.5 W All voltages ± 15 %
output output
4
Voltage selector
AC version DPDT FSH/FSL Universal voltage (DPDT relay)
24 V
max. 4 mm 2 max. 4 mm 2
115 V (AWG12) (AWG12)

230 V

8 9 10 7 6 5 1 2 8 9 10 7 6 5 4 1 2

L N PE L N PE
Signal output DPDT + - Signal output Alarm + -
Power Supply DPDT output2) Power Supply

2)
With option Fail safe alarm (rotation control)
Contact open when de-energised

SITRANS LPS200 connections

4/126 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200

■ Overview ■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting
devices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water, and wastewater industries.
A sanitary version of the ULS200, with an industry standard
flange option, is easy to remove from the application for
cleaning. It thus satisfies the prerequisites for use in the food,
beverage, and pharmaceutical industries. The Pointek ULS200
delivers superior performance while reducing maintenance,
downtime, and equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
4
The Pointek ULS200 is an ultrasonic non-contacting switch with
two switch points for level detection of bulk solids, liquids and
■ Design
slurries in a wide variety of industries; ideal for sticky materials. Installation
The Pointek ULS200 should be mounted in an area that is within
■ Benefits the temperature range specified and that is suitable to the enclo-
• 2 switch outputs for high-high, high, low and low-low level sure rating and materials of construction. The cover should be
alarms or pump up/pump down control accessible to allow programming, wiring and display viewing.
• Integral temperature compensation It is advisable to keep the Pointek ULS200 away from high volt-
• AC or DC power supply age or current runs, contactors and SCR control drives.
• Electronics provided with fail-safe function Locate the Pointek ULS200 so that it has a clear sound path
• Threaded and sanitary fitting clamp process connections perpendicular to the material surface. The sound path should
not intersect the fill path, rough walls, seams, rungs etc.
• Polycarbonate enclosure, Type 6/NEMA 6/IP67
• Easy, two-button programming Mounting and Interconnection
The Pointek ULS200 is available in three thread types: 2" NPT,
R 2" (BSPT), EN 10226 or PF2 and can be fitted with the optional
75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65,
PN 10, and JIS 10K 3B sized flanges.
Separate cables and conduit may be required to conform to
standard instrumentation wiring or electrical codes.

Siemens FI 01 · 2015 4/127


© Siemens AG 2014

Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200

■ Configuration
Parabolic mounting

Flat mounting and Beam angle

Fill

Pipe

Rungs

Seams
12°
Beam angle

Pointek ULS200 Mounting

4/128 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200

■ Technical specifications
Mode of operation Electronics/enclosure Connection: terminal block,
max. 2.5 mm2 (14 AWG) solid/
Measuring principle Ultrasonic level switch 1.5 mm2 (16 AWG) stranded
Measuring range Degree of protection IP67/Type 6/NEMA 6
Measuring range in liquids 0.25 ... 5 m (0.8 ... 16.4 ft) Cable inlet 2 x ½" NPT or 2 x PG 13.5
Measuring range in bulk solids 0.25 ... 3 m (0.8 ... 9.8 ft) Certificates and approvals • CE (EMC certificate available on
Output request), CSA US/C, FM

AC Version (relay) 2 SPDT Form C contacts, rated 5 A at


250 V AC or 30 V DC, resistive load;
rated 1 A at 48 V DC resistive load ■ Options
DC Version (relay) 2 SPDT Form C contacts, rated 5 A
at 30 V DC, resistive load; rated 1 A
at 48 V DC resistive load Flange adapter for mating 2" NPT or 2" BSP process connections to 3"
ASME, DN 65 PN 10 and JIS 10K 3B flanges
DC Version (transistor) 2 switches, rated max. 100 mA, 48 V DC
Accuracy 148.8 (5.86)
AC/DC version
• Resolution 3 mm (0.1 inch)
Bolt hole circle
diameter 4
• Repeatability 0.25 % of measuring range
Rated operation conditions
Installation conditions
190.2 (7.49)
• Location Indoors/outdoors Diameter
• Beam angle 12°
Ambient conditions Pointek ULS200 Optional Flange Adapter, dimensions in mm (inch)
• Ambient temperature -40 ... +60 °C (-40 ... +140 °F)
• If mounted in metal threads -20 ... +60 °C (-5 ... +140 °F)
Medium conditions
• Process pressure 0.5 bar (7.25 psi) max.
Design
Material Polycarbonate with gasket
Weight Approx. 1.5 kg (3.3 lb)
Transducer material PVDF or ETFE copolymer
Threaded mounting 2" NPT
[(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
• Optional flange adapter For 3" ASME, DN 65, PN 10 and
JIS 10 K3B
Sanitary mounting 4" sanitary fitting clamp
Power supply
AC version 100 ... 230 V AC, ± 15 %, 50/60 Hz,
max. 12 VA, 5 W
DC version 18 ... 30 V DC, 3 W
Displays and controls
Display LCD, three digits, 9 mm (0.35 inch)
high for display of distance between
sensor face and material, multi-segment
graphic for operating state
Memory EEPROM, non-volatile
Programming 2 keys

Siemens FI 01 · 2015 4/129


© Siemens AG 2014

Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200
Selection and Ordering data Article No. Selection and Ordering data Order code
Pointek ULS200 7ML1510- Further designs
Ultrasonic non-contacting switch with two switch Please add "-Z" to Article No. and specify Order
777 0 7
points for level detection of bulk solids, liquids and code(s)
slurries in a wide variety of industries; ideal for
sticky materials Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Click on the Article No. for the online configura- (max. 27 characters) specify in plain text
tion in the PIA Life Cycle Portal.
Operating Instructions Article No.
Power supply
Quick Start manual, multi-language A5E32268616
24 V DC, relay output ¢ 1
24 V DC, transistor output ¢ 2 This device is shipped with the Siemens Milltronics
100 ... 230 V AC, relay output ¢ 3 manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Approvals
Accessories
CE, RCM, CSA Class I, II, Div. 21) ¢ J
CE, RCM, CSAus/c, FM ¢ K Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
one text line, suitable for enclosures
Transducer/Process connection
Universal Box Bracket Mounting Kit 7ML1830-1BK
4 ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
EFTE, R 2" [(BSPT), EN 10226]
¢
¢
A
B 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
EFTE, G 2" [(BSPP), EN ISO 228-1] ¢ C
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME B1.20.1] ¢ E 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
adapter for 2" BSPT
PVDF copolymer, R 2" [(BSPT), EN 10226] ¢ F
PVDF copolymer, G [(BSPP), EN ISO 228-1] ¢ G 2" BSPT Locknut, plastic 7ML1830-1DQ

PVDF copolymer, 4" sanitary mounting2) J 2" NPT Locknut 7ML1830-1DT


Enclosure/cable inlet 4" sanitary mounting clamp 7ML1830-1BR
Polycarbonate Spare Parts
• Cable inlet PG 13.5 ¢ 1
Polycarbonate Lid 7ML1830-1LG
• Cable inlet ½" NPT ¢ 2
1)
¢ We can offer shorter delivery times for configurations designated with the
Available with Enclosure/cable inlet option 2 only Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
2) Available with Approvals option K only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/130 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Point level measurement – Ultrasonic non-contacting switch
Pointek ULS200

■ Dimensional drawings ■ Schematics


Relay output
Threaded 1 2
100 ... 230 V AC
60 50/60 Hz
(2.35) L N
74 (2.9)

1 2 3 4 5 6 7 8 9
Lid clip
57 + - Two Form ‘C’ (SPDT) relays can switch
#8-32x3/8" or
machine screw (2.25) external devices such as alarms, relays,
18 ... 30 V DC
contactors, PLCs, DCSs, etc.

Lid

4
Conduit Transistor output: DC version only
connection
½" NPT or 1 2
PG 13.5
180 (7.1)
18 ... 30 V DC
+ -

2" NPT
R 2" BSPT 22 (0.87) 1 2 3 4 5 6 7 8 9
or PF2 74 (2.9)
Transducer Two non-polarized transistor outputs are
suitable for connection to PLCs, DCSs,
or customer supplied relays.

Sanitary

Pointek ULS200 connections

180 (7.1)

74 (2.9)

Pointek ULS200, dimensions in mm (inch)

Siemens FI 01 · 2015 4/131


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic

■ Overview ■ Mode of operation


Introduction Common Terms
Ultrasonic measurement is based on the speed of sound. Sound Attenuation
can be used as a measurement tool because there is a measur-
able time lapse between sound generation and the "hearing" of Denotes a decrease in signal magnitude in transmission from
the sound. This time lapse is then converted into usable informa- one point to another. Attenuation may be expressed as a scalar
tion. Ultrasonic sensing equipment generates a sound above ratio of the input magnitude to the output magnitude or in deci-
20 000 Hz and then interprets the time lapse of the returned bels.
echo. The transducer creates the sound and senses the echo Beam angle
and then a transceiver interprets the sound and converts it into
information. The diameter of a conical boundary centered around the axis of
transmission when the power (radiating perpendicular to the
Siemens ultrasonic units include Sonic Intelligence, a patented transducer face on the axis of transmission) is reduced by half
signal processing technology. Using unique algorithms, Sonic (-3 dB).
Intelligence differentiates between true echoes from the material
and false echoes from obstructions or electrical noise, providing Blanking distance
intelligent processing of echo profiles. Specified zone extending downward from the transducer face in
4 Typical System which received echoes are ignored by the transceiver. Blanking
distance ignores echoes from ringing.
Ultrasonic level measurement requires two components: one to
generate the sound and catch the echo (transducer) and one to Echo confidence
interpret the data and derive a measurement (transceiver). Even The recognition of the validity of the echo as material level.
though some ultrasonic instruments combine the components in A measure of echo reliability.
one unit, the individual functionality remains distinct. The mea-
surement output is communicated to the unit, PLCs or PCs for Ringing
process control. The inherent nature of the transducer to continue vibrating after
Principle of Operation the transmit pulse has ceased; the decay of the transmit pulse.

A piezoelectric crystal inside the transducer converts an electri- Transducer/Transceiver


cal signal into sound energy, firing a burst into the air which trav- A transducer provides the initial ultrasonic pulse and receives its
els to the target and then is reflected back to the transducer. echo. An ultrasonic transducer amplifies the sound wave cre-
The transducer then acts as a receiving device and converts the ated by the piezoelectric crystal and transmits that sound wave
sonic energy back into an electrical signal contained in the to the face of the transducer while at the same time dampening
transceiver. An electronic signal processor analyzes the return the sound wave from the other sides of the crystal.
echo and calculates the distance between the transducer and
the target. The time lapse between firing the sound burst and Transceivers analyze the echo from the transducer to determine
receiving the return echo is directly proportional to the distance the required measurement.
between the transducer and the material in the vessel. This
basic principle lies at the heart of the ultrasonic measurement
technology and is illustrated in the equation:
Distance = (Velocity of Sound x Time)/2.

4/132 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic

■ Technical specifications
Ultrasonic Transmitter/Controller Selection Guide
Criteria SITRANS Probe LU SITRANS LUT400 HydroRanger 200 MultiRanger 100/200 SITRANS LU
Range 6 m (20 ft) or 0.3 ... 60 m (1 ... 196 ft), 15 m (50 ft) transducer 15 m (50 ft) transducer 60 m (200 ft) transducer
12 m (40 ft) transducer and application depen- and application depen- and application depen-
and application dent dent dent
dependent
Typical applications Chemical storage Wet wells, reservoirs, Wet wells, flumes/weirs, Wet wells, flumes/weirs, Chemical storage, liquid
vessels, filter beds, flumes/weirs, bar screen control bar screen control, hop- storage, bulk solids stor-
liquid storage chemical storage, pers, chemical storage, age (sugar, flour bins,
vessels liquid storage, liquid storage, crusher grains, cereals),
hoppers, crusher bins, dry solids storage plastic pellets
bins, dry solids
storage
Output HART model: 4 ... 20 mA/HART 6 relays standard, 1 relay (option on 4 relays (LU01, LU02)
4 ... 20 mA/HART 3 relays two 4 ... 20 mA outputs MultiRanger 100) Up to 40 relays (LU10)
PROFIBUS PA (isolated) 3 relays standard 4 ... 20 mA isolated
4
model: PROFIBUS
6 relays (option)
Two 4 ... 20 mA outputs
(isolated)
Communications HART or HART 7.0, USB, Built-in Modbus RTU/ Built-in Modbus RTU or Dolphin, RS-232/RS-485
PROFIBUS PA SIMATIC PDM ASCII via RS-485 ASCII via RS-485 (LU01, LU02))
Options: Options: Options: Dolphin via infrared
• SIMATIC PDM for • SIMATIC PDM • SIMATIC PDM (LU10)
remote configuration • SmartLinx • SmartLinx
and diagnostics (PROFIBUS DP, (PROFIBUS DP,
DeviceNet) DeviceNet)
Power specifications HART: AC version: AC version: AC version: LU01, LU02:
4 ... 20 mA, 100 ... 230 V AC ± 15 %, 100 ... 230 V AC ± 15 %, 100 ... 230 V AC ± 15 %, AC version:
24 V DC nominal, 50/60 Hz, 36 VA 50/60 Hz, 36 VA/17 W 50/60 Hz, 36 VA/17 W 100/115/200/
max. 550 , 30 V DC Fuse: 5 x 20 mm, DC version: DC version: 230 V AC
max. PROFIBUS PA: Slow Blow, 12 ... 30 V DC, 20 W 12 ... 30 V DC, 20 W DC version:
12, 13, 15, or 20 mA, 0.25 A, 250 V DC 18 ... 30 V DC, 25 W
dependent on program- version: LU10: 100/115/200/
ming 10 … 32 V DC, 10 W 230 V AC
Fuse: 5 x 20 mm,
Slow Blow, 1.6 A, 125 V
Approvals CE, CSAUS/C, FM, RCM, CE, CSAUS/C, UL Listed, CE, CSAUS/C, UL Listed, CE, CSAUS/C, UL Listed, CE, CSAUS/C, FM,
ATEX, IECEx FM, RCM, FM, RCM FM, RCM Lloyd’s Register
Lloyd's Register, ABS

Siemens FI 01 · 2015 4/133


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic

7ML1830-2AN 7ML5830-2AJ 7ML1830-2AK

SITRANS Probe LU HART* SITRANS Probe LU PROFIBUS MultiRanger 100/200


SITRANS LU HydroRanger 200
4
* Note: To order the IS version of this hand programmer, order 7ML5830-2AH.

Handheld programmer selection guide

4/134 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic
Ultrasonic

■ Application

Ultrasonic Level Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code:
Fax: OGGGGGP
Phone: (
E-mail:
)
4

Tanks/Vessel information (Suppy sketch where possible) Sketch attached

Type: Storage Dimensions: Critical Information

Process Height: m/ft Nozzle Length: cm/inch

Pump station Width/Diameter: m/ft Nozzle Diameter: cm/inch

Open channel

Tank top: Open Tank bottom: Sloped Internal equipment No


and/or obstructions:
Flat Flat (Eg. Agitator, heating coils, Yes Please list
supports, other)
Conical Conical

Parabolic Parabolic

Measurement type: Point Level Continuous Level Volume Flow


Area safety classification: (Specify code required)

Material
Material being measured: Slurry Liquid Solid

Material temperature: Norm: °C/°F Max: °C/°F

Atmosphere: Air Other Homogenous: Yes No

Dust: None Light Heavy

Installation (indicate all that apply)

Power available: Communications:


Inputs required: Outputs required: HART/4 ... 20 mA AB Remote I/O
4 ... 20 mA 4 ... 20 mA PROFIBUS DP AB DeviceNet

Pump Interlocks (#): Relays (#): PROFIBUS PA Other


Modbus RTU/ASCII None

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-769R4

Ultrasonic Application Questionnaire

Siemens FI 01 · 2015 4/135


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU

■ Overview ■ Configuration
Parabolic mounting

4
SITRANS Probe LU is a 2-wire loop powered ultrasonic transmit-
ter for level, volume and flow monitoring of liquids in open chan-
nels, storage vessels, and simple process vessels.
Flat mounting and beam angle
■ Benefits Fill

• Continuous level measurement up to 12 m (40 ft) range


• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART Communicator
• Communication using HART or PROFIBUS PA
• ETFE or PVDF transducers for chemical compatibility Pipe
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression for fixed obstruction avoidance
• Level to volume or level to flow conversion Rungs

■ Application
Seams
The SITRANS Probe LU is ideal for level monitoring in the water
and wastewater industry, chemical storage vessels, and small 10°
bulk hoppers. Beam angle
The range of SITRANS Probe LU is 6 or 12 m (20 or 40 ft).
Using Sonic Intelligence, Auto False Echo Suppression for fixed
obstruction avoidance, and accuracy of 0.15 % of range or
6 mm (0.25 inch), the Probe LU provides unmatched reliability. SITRANS Probe LU mounting
The Probe LU offers two communications options: HART or
PROFIBUS PA (Profile version 3.0, Class B).
The transducer on the Probe LU is available as ETFE or PVDF to
suit the chemical conditions of your application. As well,
for applications with varying material and process temperatures,
the Probe LU incorporates an internal temperature sensor to
compensate for temperature changes.
• Key Applications: chemical storage vessels, filter beds,
liquid storage vessels

4/136 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU

■ Technical specifications
Mode of operation Process connection
Measuring principle Ultrasonic level measurement • Threaded connection 2" NPT [(Taper), ANSI/ASME B1.20.1]
Typical application Level measurement in storage ves- R 2" [(BSPT), EN 10226] or
sels and simple process vessels G 2" [(BSPP), EN ISO 228-1]
Inputs • Flange connection 3 inch (80 mm) universal flange
Measuring range • Other connection FMS 200 mounting bracket
• 6 m (20 ft) model 0.25 ... 6 m (10 inch ... 20 ft) (see page 4/187) or customer
• 12 m (40 ft) model 0.25 ... 12 m (10 inch ... 40 ft) supplied mount

Frequency 54 kHz Display and Controls

Outputs Interface Local: LCD display with bar graph


Remote: Available via HART or
mA/HART
PROFIBUS PA
• Range 4 ... 20 mA
Configuration Using Siemens SIMATIC PDM (PC) or
• Accuracy ± 0.02 mA HART handheld communicator or

4
Siemens infrared handheld program-
PROFIBUS PA Profile 3, Class B mer
Performance Memory Non-volatile EEPROM
Resolution  3 mm (0.12 inch) Power supply
Accuracy ± the greater of 0.15 % of range or 4 ... 20 mA/HART Nominal 24 V DC with 550  maxi-
6 mm (0.24 inch) mum; maximum 30 V DC 4 ... 20 mA
Repeatability  3 mm (0.12 inch) PROFIBUS PA 12, 13, 15, or 20 mA depending on
Blanking distance 0.25 m (10 inch) programming (General Purpose or
Intrinsically Safe version)
Update time 5s
per IEC 61158-2
• 4 ... 20 mA/HART version  5 s at 4 mA
Certificates and Approvals
• PROFIBUS version  4 s at 15 mA current loop
General CSAUS/C, FM, CE, RCM
Temperature compensation Built-in to compensate over tempera-
ture range Marine (only applies to • Lloyd’s Register of Shipping
HART communication option) • ABS Type Approval
Beam angle 10°
Hazardous
Rated operating conditions
• Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 Ga
Ambient conditions
• Intrinsically Safe (USA/Canada) CSA/FM, Class I, Div. 1,
• Location Indoor/outdoor Groups A, B, C, D; Class II, Div. 1,
• Ambient temperature -40 ... +80 °C (-40 ... +176 °F) Groups E, F, G; Class III T4
• Relative humidity/ingress protection Suitable for outdoor • Intrinsically Safe (International) SIR 13.0008X Ex ia IIC T4 Ga
• Installation category I • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga
• Pollution degree 4 • Non-incendive (USA) FM Class I, Div. 2, Groups A, B, C, D
T4
• Medium conditions
Handheld Programmer
- Temperature at flange or threads -40 ... +85 °C (-40 ... +185 °F)
Intrinsically Safe Siemens handheld Infrared receiver
- Pressure (vessel) 0.5 bar g (7.25 psi g) programmer
Design • Approvals for handheld programmer ATEX II 1GD / IECEx SIR 09.0073
Material (enclosure) PBT (Polybutylene Terephthalate) Ex ia IIC T4 Ga
Degree of protection Type 4X/NEMA 4X, Type 6/ Ex iaD 20 T135 °C
NEMA 6/IP67/IP68 enclosure FM/CSA Class I, II, III, Div. 1,
Weight 2.1 kg (4.6 lb) Groups A,B,C,D,E,F,G T6

Cable inlet 2 x M20x1.5 cable gland or Ambient temperature -20 ... 50 °C (-5 ... 122 °F)
2 x ½" NPT thread or Interface Proprietary infrared pulse signal
1 x M20 x 1.5 and 1 x ½" NPT
Power 3 V lithium battery (non-replaceable)
Material (transducer) ETFE (Ethylene Tetrafluoroethylene)
or PVDF (Polyvinylidene Fluoride)

Siemens FI 01 · 2015 4/137


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS Probe LU 7ML5221- Further designs
2-wire, loop powered ultrasonic transmitter for 7 7 7 77 Please add "-Z" to Article No. and specify Order
level, volume and flow monitoring of liquids in code(s).
open channels, storage vessels, and simple
process vessels. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Click on the Article No. for the online configura- (max. 27 characters) specify in plain text
tion in the PIA Life Cycle Portal.
Operating Instructions for HART/mA device Article No.
Enclosure/Cable Inlet
Plastic (PBT), 1 x M20x1.5 and 1 x ½" NPT ¢ 0 English A5E32337695
(no cable glands supplied) French 7ML1998-5HT11
Plastic (PBT), 2 x M20x1.5 (includes 1 general ¢ 1
purpose cable gland: 7ML1930-1AM) German A5E34957881
Plastic (PBT), 2 x ½" NPT ¢ 2 Note: The Operating Instructions should be
(no cable glands supplied) ordered as a separate item on the order.
Range/Transducer material Additional Multi-language Quick Start manual A5E32168031
6 m (20 ft), ETFE ¢ A This device is shipped with the Siemens Milltronics
6 m (20 ft), PVDF Copolymer ¢ B manual DVD containing the ATEX Quick Start and
Operating Instructions library.

4 12 m (40 ft), ETFE


12 m (40 ft), PVDF Copolymer
¢
¢
C
D Operating Instructions for PROFIBUS PA device

Process connection English A5E32337708


2" NPT [(Taper), ANSI/ASME B1.20.1] ¢ A German A5E34957884
R 2" [(BSPT), EN 10226] ¢ B Note: The Operating Instructions should be
G 2" [(BSPP), EN ISO 228-1] ¢ C ordered as a separate item on the order.
Communication/Output Additional Multi-language Quick Start manual A5E32081626
4 ... 20 mA, HART ¢ 1 This device is shipped with the Siemens Milltronics
PROFIBUS PA ¢ 2 manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Approvals
General Purpose, FM, CSAUS/C, CE, RCM, KCC ¢ 1 Accessories
Non-incendive, FM Class I, Div. 2 Groups A,B,C,D ¢ 4 Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH
1)
T5
Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A, ¢ 5 Handheld programmer, General Purpose approvals 7ML1830-2AN
B, C, D; Class II, Div. 1, Groups E, F, G; Class III T42) Handheld programmer, Infrared, Intrinsically Safe, 7ML5830-2AJ
Intrinsically Safe ATEX 1G / IECEx / INMETRO ¢ 6 PROFIBUS PA
Ex ia IIC T4 Ga, RCM, KCC2)
Intrinsically Safe ATEX 1G / IECEx / INMETRO ¢ 7 HART modem/USB 7MF4997-1DB
Ex ia IIC T4 Ga, RCM, KCC3) (for use with a PC and SIMATIC PDM)
Intrinsically safe, CSA/FM Class I, Div. 1, Groups A, ¢ 8 2" NPT locknut, plastic 7ML1830-1DT
B, C, D; Class II, Div. 1 Groups E, F, G; Class III T43)
1)
2" BSPT locknut, plastic 7ML1830-1DQ
Available with Enclosure/Cable Inlet option 2 only.
2)
Available with communication option 2 only.
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
adapter for 2" NPT
3)
Available with communication option 1 only.
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
¢ We can offer shorter delivery times for configurations designated with the adapter for 2" BSPT
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. One General Purpose polymeric cable gland 7ML1930-1AM
M20x1.5, rated for -20 ... +80 °C (-4 ... +176 °F)
One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 ... +80 °C (-40 ... +176 °F) for
General Purpose or ATEX EEx e installations
(available for HART only)
One metallic cable gland M20x1.5, 7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F) with integrated
shield connection (available for PROFIBUS PA)
Probe LU, rock guard/sunshield kit, 7ML1930-1GH
304 stainless steel
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch see point
level measurement section.
Spare Parts
Plastic lid 7ML1830-1KB

4/138 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU

■ Options
Flange adapter for mating 2" NPT or 2" BSP process connections to SITRANS Probe LU with FMS 200 mounting bracket
3" ASME, DN 65 PN 10 and JIS 10K 3B flanges

148.8 (5.86)
Bolt hole circle
diameter

190.2 (7.49)
Diameter

SITRANS Probe LU optional flange adapter, dimensions in mm (inch) SITRANS Probe LU with optional mounting bracket

■ Dimensional drawings 4
139.7 (5.50)

Hinged lid
130.1 (5.12)
198.9 (7.83)

Electronics

Mounting thread
21
(0.83)

Transducer
51.1
(2.01)
54 (2.13)

Note: Above model is shown without M20 cable glands or 1/2" NPT conduit connectors.

SITRANS Probe LU, dimensions in mm (inch)

Siemens FI 01 · 2015 4/139


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS Probe LU

■ Schematics
Connect the wires to the
terminals as shown:
the polarity is identified
on the terminal block.
Lid screws Terminals for loop current
or PROFIBUS PA cable

Cable

Watertight
gland

Note:
- HART model above is shown with M20 cable glands. 1/2" NPT threaded connection is also available.
- DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
- All field wiring must have insulation suitable for rated input voltages.
- Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS Probe LU connections

4/140 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe

■ Overview ■ Configuration
Parabolic mounting

4
The Probe is a short-range integrated ultrasonic level transmitter,
ideal for liquids and slurries in open or closed vessels.

■ Benefits Flat mounting and beam angle


• Easy to install, program and maintain
• Accurate and reliable
Fill
• Sanitary models available
• Patented Sonic Intelligence echo processing
• Integral temperature compensation

■ Application
The transducer is available in PVDF copolymer, making the
device suitable for use in a wide variety of applications. Pipe
The Probe is easy to install and maintain, and can be quickly
removed for cleaning as required by the food, beverage and Rungs
pharmaceutical industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between the Seams
true echo and false echoes from acoustic or electrical noises 12°
and agitator blades in motion. The ultrasonic pulse propagation Beam angle
time to the material and back is temperature-compensated and
converted into distance for display, analog output and relay
actuation.
• Key Applications: chemical storage vessels, filter beds, The Probe mounting
mud pits, liquid storage vessels, food applications

Siemens FI 01 · 2015 4/141


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe

■ Technical specifications Selection and Ordering data Article No.


The Probe 7ML1201-
Three-wire version Two-wire version
(standard) Short-range integrated ultrasonic level transmitter, 777 0 0
ideal for liquids and slurries in open or closed
Mode of operation vessels
Measuring principle Ultrasonic level Ultrasonic level Click on the Article No. for the online configura-
measurement measurement tion in the PIA Life Cycle Portal.
Input Measuring range
Measuring range 0.25 ... 5 m 0.25 ... 5 m 5 m (16.40 ft) ¢ 1
(0.8 ... 16.4 ft) (0.8 ... 16.4 ft) Transducer/Process connection
Frequency 54 kHz 54 kHz PVDF copolymer, 2" NPT [(Taper), ¢ E
Output ANSI/ASME B1.20.1]
• mA 4 ... 20 mA 4 ... 20 mA PVDF copolymer, R 2" [(BSPT), EN 10226] ¢ F
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] ¢ G
- Span Proportional/ Proportional/ PVDF copolymer, 4" Sanitary mounting ¢ J
inversely proportional inversely proportional
Model/Approval
- Max. load 750  at 24 V DC 600  in the loop at 3 Wire, 24 V DC, CE, RCM, CSA, FM ¢ E
4 • Relay For level alarm or fault
24 V DC
No
2 Wire, 24 V DC, CE, RCM, CSA ¢ F
¢ We can offer shorter delivery times for configurations designated with the
Power supply Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Supply voltage 18 ... 30 V DC, 12 ... 30 V DC,
max. 0.2 A 0.1 A surge
Selection and Ordering data Order code
Max. power consump- 5W 0.75 W Further designs
tion (200 mA at 24 V DC) (25 mA at 24 V DC)
Please add "-Z" to Article No. and specify Order
Certificates and CE, RCM, CSAUS/C, FM CE, RCM, CSAUS/C
approvals
code(s).

Accuracy Acrylic coated, stainless steel tag [13 x 45 mm ¢ Y17


(0.5 x 1.75 inch)]: Measuring-point number/
• Error in measurement 0.25 % of measuring range (in air) identification (max. 20 characters) specify in
• Resolution 3 mm (0.125 inch) plain text
• Temperature compen- Built in Additional Operating Instructions Article No.
sation
• Echo processing Sonic Intelligence 3 Wire, 24 V model, Multi-language manual 7ML1998-5GD62
Rated operation condi- 2 Wire model, Multi-language manual A5E32243983
tions
• Beam angle 12° Accessories
• Ambient temperature Universal Box Bracket Mounting kit 7ML1830-1BK
- Standard -40 ... +60 °C (-40 ... +140 °F)
Sanitary 4" mounting clamp 7ML1830-1BR
- Metallic mounting -20 ... +60 °C (-4 ... +140 °F)
• Max. static operating Normal atmospheric pressure 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
pressure adapter for 2" NPT
• Degree of protection IP65 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
Design adapter for 2" BSPT
• Weight 2" NPT locknut, plastic 7ML1830-1DT
- Without flange 1.5 kg (3.3 lb)
adapter 2" BSPT locknut, plastic 7ML1830-1DQ
- With flange adapter 1.7 kg (3.7 lb) Plastic M20 cable gland with metal locknut 7ML1930-1DB
• Material
SITRANS RD100, loop powered display - 7ML5741-...
- Electronics enclo- PVC
see Chapter 7
sure
- Transducer PVDF copolymer SITRANS RD200, universal input display with 7ML5740-...
• Degree of protection IP65 Modbus conversion - see Chapter 7
• Process connection 2" NPT [(Taper), ANSI/ASME B1.20.1] SITRANS RD300, dual line display with totalizer 7ML5744-...
R 2" [(BSPT), EN 10226] or and linearization curve and Modbus conversion -
G 2" [(BSPP), EN ISO 228-1] see Chapter 7
• Flange adapter 3" Universal,
(fits DN 65, PN 10 and 3"ASME) SITRANS RD500 web, universal remote monitoring 7ML5750-...
4" sanitary solution for instrumentation - see Chapter 7
• Cable inlet 2 inlets for PG 16 or ½" NPT cable glands For applicable back up point level switch see point
level measurement section.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/142 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transmitters
The Probe

■ Options ■ Dimensional drawings


Flange adapter for mating 2" NPT or 2" BSP process connections to Standard model
3" ANSI, DN 65 PN10, and JIS 10K 3B flanges
Hinged lid

7 (0.3)
148.8 (5.86)
bolt hole circle
diameter 84 (3.3) max.

117 (4.6)

190.2 (7.49)
diameter
Cable entry
‘knock out’

279 (11)
The Probe Optional Flange Adapter, dimensions in mm (inch) Electronics

The Probe with FMS 200 mounting bracket 87


(3.4) Ø Mounting
thread
4
Mounting
transducer

(2.9)
thread

74
61 (2.4) 53 (2.1) max.

Sanitary model

7 (0.3)
Hinged 84 (3.3) max.
The Probe with Optional Mounting Bracket
lid

■ Schematics 117 (4.6)

3 wire model
(standard and sanitary models)
Cable entry
‘knock out’
279 (11)

Electronics

mA output: 4 ... 20 mA, non- 87


isolated, 750 Ω max. Process
(3.4) Ø
Power supply connection
(2.9)
74

Connect to protective earth


Relays: dry contact, closed Transducer
unpowered or alarm state

61 (2.4) 53 (2.1) max.


2 wire model Loop
(standard and sanitary models) instrumentation
Probe R max The Probe, dimensions in mm (inch)
+ – + –
1 2

V supply – 12 V
R max = +
20 mA
V supply 12 ... 30 V DC –

Display Program Segment


mode display

'20' key

Units
'4' key
Operation LOE/fault
status

The Probe connections

Siemens FI 01 · 2015 4/143


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series

■ Overview ■ Application
The SITRANS LUT400 comes in three different models, depend-
ing on the application, level of performance and functionality
required:
• SITRANS LUT420 Level Controller: Level or volume
measurement of liquids, slurries, and solids, as well as basic
pump control functions, and basic data logging capability
• SITRANS LUT430 Level, Pump and Flow Controller: Includes
all features of the LUT420 plus a full suite of advanced pump
control and alarm functionality, open channel flow monitoring,
and basic flow data logging capability
• SITRANS LUT440 High Accuracy OCM: Our most featured,
highest accuracy model. Includes all features of the LUT430,
plus the industry’s best accuracy (± 1 mm within 3 m), full suite
of advanced control functionality, and enhanced flow logging
capability
4 • Key applications: wet wells, reservoirs, flumes/weirs, chemical
storage, liquid storage, hoppers, crusher bins, dry solids
storage
The Siemens SITRANS LUT400 series controllers are compact,
single point, long-range ultrasonic controllers for continuous
level or volume measurement of liquids, slurries, and solids,
and high accuracy monitoring of open channel flow.

■ Benefits
• Small 1/2 DIN enclosure [144 h x 144 d x 146 w mm
(5.7 x 5.7 x 5.75 inch)] with standard universal mounting
bracket for wall, pipe, and DIN rail, plus an optional panel
mount
• Easy to use HMI display with local four-button programming,
menu-driven parameters, and Wizard support for key applica-
tions
• English, German, French, Spanish, Chinese, Italian, Portu-
guese, and Russian texts on the HMI.
• Level, Volume, OCM Flow monitoring
• Three relays combined with a suite of pump, alarm, and relay
control features
• HART Communications
• EDDs for SIMATIC PDM, AMS Device Manager, and Field
Communicator 375/475, plus DTMs for FDTs (Field Device
Tools)
• Web browser for local programming from an intuitive web-
based interface
• Two discrete inputs for backup level override and pump
interlock functions
• Echo profile and trend views from the local display
• Patented digital receiver for improved performance in electri-
cally noisy applications (close proximity to VSDs)
• Real time clock with daylight savings time, supporting an
integrated datalogger and energy saving algorithms for
minimizing pump operation during high cost energy periods
• Removable terminal blocks for ease of wiring
• MCERTS Certified for Open Channel Flow

4/144 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series

■ Technical specifications
Mode of Operation Ultrasonic level, volume, pump, Design
and open channel flow
Weight
Measuring range 0.3 … 60 m (1 … 196 ft), • Enclosure with display lid 1.3 kg (2.87 lb)
transducer dependent • Enclosure with blank lid: 1.2 kg (2.65 lb)
Input Material (enclosure) Polycarbonate
Discrete 0 ... 50 V DC switching level Degree of protection
Logical 0  10 V DC • Enclosure with display or blank lid: IP65/Type 4X/NEMA 4X
Logical 1 = 10 ... 50 V DC
• Enclosure with blank lid and knock- IP20
Max. 3 mA
out removed:
Output
Remote display lid: IP65/Type 3/NEMA 3
Transducer frequency 10 ... 52 kHz
Cable
Ultrasonic transducer Compatible transducers: All Echo-
Transducer and mA output signal • Transducer, mA output:
Max and ST-H series transducers
2 copper conductors, twisted,
Relays • 1 SPDT Form C, NO or NC relay, with foil shield/drain wire, 300 V
0.5 … 0.75 mm² (22 … 18 AWG)
4
rated 1A at 250 V AC,
non-inductive and 3A at 30 V DC • Relay/power to be copper
• 2 SPST Form A, NO relays, conductors per local
rated 5A at 250 V AC, requirements to meet 250 V
non-inductive and 3 A at 30 V DC 5 A contact rating
mA output 4 … 20 mA, isolated Max. separation between 365 m (1 200 ft)
• Max. load 600  max. in ACTIVE mode, transducer and transceiver
750  max. in PASSIVE mode Displays and controls 60 x 40 mm (2.36 x 1.57 inch)
• Resolution 0.1 % of range removable
LCD, 240 x 160 pixels resolution,
Accuracy operational up to 5 m from
Error in measurement • Standard operation: ± 1 mm enclosure base
(0.04 inch) plus 0.17 % of measured Programming
distance
• High accuracy OCM: ± 1 mm • Primary 4 Local push buttons
(0.04 inch), within 3 m (9.84 ft) • Secondary • PC running SIMATIC PDM
range • PC running Emerson AMS Device
Manager
Resolution • Standard operation: 0.1 % of range • PC running a web browser
or 2 mm (0.08 inch), whichever is • PC running a Field Device Tool
greater (FDT)
• High accuracy OCM: 0.6 mm • Field Communicator 375/475
(0.02 inch), within 3 m (9.84 ft) (FC375/FC475)
range
Memory • 512 kB flash EPROM
Temperature compensation • -40 ... +150 °C (-40 ... +300 °F) • 1.5 MByte flash for data logging
• Integral temperature sensor in trans-
ducer Power supply
• External TS-3 temperature sensor
AC version 100 ... 230 V AC ± 15 %,
(optional)
50/60 Hz, 36 VA
• Programmable fixed temperature
Fuse: 5 x 20 mm, Slow Blow,
values
0.25 A, 250 V
Rated operating conditions
DC version 10 … 32 V DC, 10 W
Installation conditions Fuse: 5 x 20 mm, Slow Blow,
• Location Indoor/outdoor 1.6 A, 125 V
• Installation category II Certificates and approvals
• Pollution degree 4 General CSAUS/C, CE, FM, UL listed, RCM,
Ambient conditions MCERTS certified for
• Ambient temperature (enclosure) -20 … +50 °C (-4 … +122 °F) Open Channel Flow
Hazardous
• Non-incendive CSA Class I, Div. 2,
(Canada) Groups A, B, C, D;
Class II, Div. 2, Groups F, G;
Class III
• Shipping Lloyd's Register, ABS
Communication HART 7.0, USB

Siemens FI 01 · 2015 4/145


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
SITRANS LUT420 SITRANS LUT430 SITRANS LUT440
Category Feature Level Controller Level, pump and flow High accuracy OCM
controller controller
Operations Level, space, and distance   
measurement
Open channel flow measure-  
ment
Volume conversion   
Specifications Compatible with EchoMax and   
ST-H transducers
Standard accuracy: ± 1 mm   
+0.17 % of measured distance
High accuracy: ± 1 mm within 
3 meters
Mounting options: wall or   
panel, pipe, DIN-rail

4 Data logging and communi-


cations
HART communications   

4 ... 20 mA output (active and   


passive)
Integrated datalogger for   
measurement value and
alarms
Integrated datalogger for fixed  
rate flow logging
Integrated datalogger for 
variable rate flow logging
triggered by changes in flow
condition
Daily data logging for maxi-  
mum, minimum and average
flow, daily totalized volume,
and minimum and maximum
temperature
Flow monitoring High accuracy open channel 
flow measurement
9 digit daily and running flow  
totalizers
High and low flowrate alarms  
External totalizer and sampler  
control
MCERTS Class 1 Certification 
MCERTS Class 2 Certification 
Pump control Energy saving algorithms for  
pump control
Wall cling reduction   
Pump run-on functionality  
Pump start and power  
resumption delays
Alternate duty pump routines   
Fixed duty and service ratio  
pump routines
Pumped volume totalizer  
Submergence detection   
Discrete input pump interlocks  
Time to spill calculation  

4/146 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
Selection and Ordering data Article No. Communications Manual
SITRANS LUT420 and LUT430 7ML5050- English 7ML1998-5NE01
Compact ultrasonic level controllers for continuous
short to long-range level or volume measurement of 00 7 7 7 7 0- 7 77 00 French 7ML1998-5NE11
liquids, slurries, and solids. Both units include Spanish 7ML1998-5NE21
basic relay functions for pumps, alarms, and other
controls, plus onboard data logging. LUT430 offers German 7ML1998-5NE31
additional advanced pump control and alarm
Italian 7ML1998-5NE51
functionality, open channel flow monitoring,
and basic flow data logging capability. Note: The communications manual should be
Functionality varies by model. ordered as a separate line item on the order.

Click on the Article No. for the online configura- Accessories


tion in the PIA Life Cycle Portal. Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
Model one text line, suitable for enclosure
SITRANS LUT420 - Level controller ¢ A TS-3 Temperature Sensor - see TS-3 on page 4/189 7ML1813-...
SITRANS LUT430 - Level, Pump & Flow controller ¢ B Panel mount cable extension, 2.5 m (8.2 ft) 7ML1930-1GF
Enclosure display options Qty 3 cable glands and retaining nuts 7ML1930-1GB
¢
4
With display A
With remote panel mount display ¢ B USB cable, 2 m (6.56 ft) - Standard USB-A to 7ML1930-1GD
[Includes panel mount cable extension, 2.5 m USB-mini B
(8.2 ft)] Hart modem/USB 7MF4997-1DB
No display (blank lid provided) ¢ C (for use with a PC and SIMATIC PDM)
Note: Enclosure includes back-plate for wall Sunshield, 304 stainless steel 7ML1930-1GE
and pipe mounting, and an integrated clip for
DIN-rail mounting. DIN-rail mounting for standard SITRANS RD100, loop powered display - 7ML5741-...
TS35 x 7.5 and TS35 x 15 mm DIN-rail to see Chapter 7
IEC 60715, EN 60715
SITRANS RD200, universal input display with 7ML5740-...
Input voltage Modbus conversion - see Chapter 7
100 ... 230 V AC ± 15 % ¢ 1 SITRANS RD300, dual line display with totalizer and 7ML5744-...
10 ... 32 V DC ¢ 2 linearization curve and Modbus conversion - see
Cable inlet Chapter 7
3 cable inlets, cable glands not supplied ¢ 1 SITRANS RD500 web, universal remote monitoring 7ML5750-...
3 cable inlets, 3 M20 plastic cable glands supplied¢ 2 solution for instrumentation - see Chapter 7

Number of measurement points Spare parts


Single point system (includes one transducer input, ¢ 1 Panel mount retrofit kit (convert standard unit with 7ML1830-1PA
one mA output, and one external temperature display to panel mount version)
sensor input)
Terminal block replacement kit 7ML1830-1PB
Communications and I/O (5 piece kit with one of each removable terminal)
HART, 2 discrete inputs, 3 relays ¢ D Wall/Pipe mount plate 7ML1830-1PC
Approvals Enclosure (include blank label) 7ML1830-1PD
General purpose CE, FM, CSAUS/C, UL, RCM ¢ A
Hazardous locations CSA Class I, II, III, Div. 2 C SITRANS LUT400 Lid (with Display) 7ML1830-1PE
(Groups A, B, C, D, F, G) SITRANS LUT400 Lid (blank) 7ML1830-1PF
¢ We can offer shorter delivery times for configurations designated with the Fuse - AC (0.25 A, 250 V, Slow Blow) 7ML1830-1PG
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Fuse - DC (1.6 A, 125 V, Slow Blow) 7ML1830-1PH
Battery BR2032 7ML1830-1PJ
Panel mount gasket and fastener kit 7ML1830-1PK
Selection and Ordering data Order code
Further designs DIN-rail clip 7ML1830-1PL

Please add "-Z" to Article No. and specify Order ¢ We can offer shorter delivery times for configurations designated with the
code(s). Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Manufacturer's test certificate M to DIN 55350, ¢ C11


Part 18 and to ISO 9000
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Namur NE43 failsafe setting - device preset to ¢ N07
failsafe < 3.6 mA
Operating Instructions Article No.
English 7ML1998-5MV01
French 7ML1998-5MV11
Spanish 7ML1998-5MV21
German 7ML1998-5MV31
Italian 7ML1998-5MV51
Multi-language compact operating instructions 7ML1998-5XU81
Note: The operating instructions should be
ordered as a separate line item on the order.

Siemens FI 01 · 2015 4/147


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series
Selection and Ordering data Article No. Communications Manual
SITRANS LUT440 7ML5050- English 7ML1998-5NE01
The SITRANS LUT440 is the most accurate and
featured model in the LUT400 series. It includes 00 7 7 7 7 0- 7 77 00 French 7ML1998-5NE11
high accuracy open channel monitoring, relay Spanish 7ML1998-5NE21
functions for external samplers, totalizers, alarms,
and enhanced data logging, as well as all pump German 7ML1998-5NE31
and control functions available with other models in
Italian 7ML1998-5NE51
the LUT400 series.
Note: The communications manual should be
Click on the Article No. for the online configura-
ordered as a separate line item on the order.
tion in the PIA Life Cycle Portal.
Accessories
Model
SITRANS LUT440 - High accuracy Open Channel ¢ C Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
Monitor1) one text line, suitable for enclosure
Enclosure display options TS-3 Temperature Sensor - see TS-3 on page 4/189 7ML1813-...
With display ¢ A Panel mount cable extension 2.5 m (8.2 ft) 7ML1930-1GF
With remote panel mount display ¢ B
Qty 3 cable glands and retaining nuts 7ML1930-1GB
4
[Includes panel mount cable extension, 2.5 m
(8.2 ft)] USB cable 2 m (6.56 ft) - Standard USB-A to 7ML1930-1GD
No display (blank lid provided) ¢ C USB-mini B
Note: Enclosure includes back-plate for wall HART modem/USB 7MF4997-1DB
and pipe mounting, and an integrated clip for (for use with PC and SIMATIC PDM)
DIN-rail mounting. DIN-rail mounting for standard
TS35 x 7.5 and TS35 x 15 mm DIN-rail to Sunshield, 304 stainless steel 7ML1930-1GE
IEC 60715, EN 60715
SITRANS RD100, loop powered display - 7ML5741-...
Input voltage see Chapter 7
100 ... 230 V AC ± 15 % ¢ 1 SITRANS RD200, universal input display with 7ML5740-...
10 ... 32 V DC ¢ 2 Modbus conversion - see Chapter 7
Cable inlet SITRANS RD300, dual line display with totalizer and 7ML5744-...
3 cable inlets, cable glands not supplied ¢ 1 linearization curve and Modbus conversion - see
3 cable inlets, 3 M20 plastic cable glands supplied¢ 2 Chapter 7

Number of measurement points SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
Single point system (includes one transducer input, ¢ 1
one mA output, and one external temperature Spare parts
sensor input)
Panel mount retrofit kit (convert standard unit with 7ML1830-1PA
Communications and I/O display to panel mount version)
HART, 2 discrete inputs, 3 relays ¢ D Terminal block replacement kit 7ML1830-1PB
Approvals (5 piece kit with one of each removable terminal)
General purpose CE, FM, CSAUS/C, UL, RCM ¢ A Wall/Pipe mount plate 7ML1830-1PC
Hazardous locations CSA Class I, II, III, Div. 2, C
(Groups A, B, C, D, F, G) Enclosure (include blank label) 7ML1830-1PD
1)
Compatible with all EchoMax Transducers. High accuracy OCM
SITRANS LUT400 Lid (with Display) 7ML1830-1PE
performance with the use of an XRS-5 transducer and TS-3 temperature SITRANS LUT400 Lid (blank) 7ML1830-1PF
sensor (each sold separately).
Fuse - AC (0.25 A, 250 V, Slow Blow) 7ML1830-1PG
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. Fuse - DC (1.6 A, 125 V, Slow Blow) 7ML1830-1PH
Battery BR2032 7ML1830-1PJ
Panel mount gasket and fastener kit 7ML1830-1PK
Selection and Ordering data Order code
DIN-rail clip 7ML1830-1PL
Further designs
Please add "-Z" to Article No. and specify Order ¢ We can offer shorter delivery times for configurations designated with the
code(s). Quick Ship Symbol ¢. For details see page 9/5 in the appendix

Manufacturer's test certificate M to DIN 55350, ¢ C11


Part 18 and to ISO 9000
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Namur NE43 failsafe setting - device preset to ¢ N07
failsafe < 3.6 mA
Operating Instructions Article No.
English 7ML1998-5MV01
French 7ML1998-5MV11
Spanish 7ML1998-5MV21
German 7ML1998-5MV31
Italian 7ML1998-5MV51
Note: The operating instructions should be
ordered as a separate line item on the order.

4/148 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series

■ Dimensional drawings
Back Enclosure
mount
bracket

SITRANS LUT400

198
(7.8)

190
(7.5)

144
(5.7)

34
(1.34)
22
(0.87) 33 98°
(1.34)

Cable entry 259


(3 places) (10.2)

155
(6.10)

146
(5.75)

45
(1.2)

SITRANS LUT400, dimensions in mm (inch)

Siemens FI 01 · 2015 4/149


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series

110.00 ± 1.00
1.80 ± 1.00 (4.33 ± 0.04)
(0.07 ± 0.04)
13.50 ± 1.00 5.50 (0.22) dia.
(0.53 ± 0.04) (4 places)

6.25 (0.25) rad.


(3.81 ± 0.04) (4 places)
97.00 ± 1.00
125.00
(4.92)

Cut-out
Note: Cut-out template

4 (printed to scale) shipped


with remote panel mount
model.

125.00
(4.92)

SITRANS LUT400, dimensions in mm (inch)

4/150 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LUT400 series

■ Schematics

INPUT
POWER

12 13 14
1.6 A,125 V
SLOW BLOW 10 - 32 V

INPUT
TS-3 TRANSDUCER DISCRETE INPUTS POWER

1 2 3 4 5 6 7
1
8
2
9 10 1
DC SYNC
0.25 A, 250 V
12
L1
13
L2/N
14 4
SHLD

SLOW BLOW
WHT
WHT

XWWGTGYZWG}
BLK

BLK

RELAYS mA OUT/HART BATTERY


BR2032

DISPLAY
15 16 17 18 19 20 21 22 23 24

RLY 1 RLY 2 RLY 3


PAS
ACT
SERVICE

SITRANS LUT400 connections

Siemens FI 01 · 2015 4/151


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200

■ Overview ■ Application
MultiRanger can be used on different materials, including fuel
oil, municipal waste, acids, woodchips, or on materials with high
angles of repose. MultiRanger offers true dual point monitoring,
digital communications with built-in Modbus RTU via RS-485,
as well as compatibility with SIMATIC PDM, allowing PC config-
uration and setup. MultiRanger features Sonic Intelligence
advanced echo-processing software for increased reading reli-
ability.
MultiRanger 100 offers cost-effective level alarming, as well as
on/off and alternating pump control. MultiRanger 200 will monitor
open channel flow and features more advanced relay alarming
and pump control functions as well as volume conversion.
It is compatible with chemical-resistant EchoMax transducers
that can be used in hostile environments at temperatures as high
as 145 °C (293 °F).
4 • Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins,
dry solids storage
MultiRanger is a versatile short to medium-range ultrasonic
single and multi-vessel level monitor/controller for virtually any
application in a wide range of industries.
■ Design
The MultiRanger is available in wall or panel mounting options.
■ Benefits
• Digital input for back-up level override from point level device
• Communication using built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM
configuration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise
reduction and improved signal-to-noise ratio
• MultiRanger 100: level measurements, simple pump control,
and level alarm functions
• MultiRanger 200: level, volume and flow measurements in
open channels, differential control, extended pump control,
and alarm functions
• Wall and panel mounting options

4/152 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200

■ Technical specifications
Mode of Operation Design
Measuring principle Ultrasonic level measurement Weight
• Wall mount 1.37 kg (3.02 lb)
Measuring range 0.3 ... 15 m (1 ... 50 ft) • Panel mount 1.50 kg (3.31 lb)
Measuring points 1 or 2 Material (enclosure) Polycarbonate
Input Degree of protection (enclosure)
• Analog (MultiRanger 200 only) 0 ... 20 mA or 4 ... 20 mA, from alter- • Wall mount IP65/Type 4X/NEMA 4X
nate device, scalable • Panel mount IP54/Type 3/NEMA 3
• Discrete 10 ... 50 V DC switching level Electrical connection
Logical 0  0.5 V DC • Transducer and mA output signal 2-core copper conductor, twisted,
Logical 1 = 10 ... 50 V DC shielded, 0.5 ... 0.75 mm²
Max. 3 mA (22 ... 18 AWG), Belden 8760 or
Output equivalent is acceptable
EchoMax transducer 44 kHz • Max. separation between 365 m (1 200 ft)
Ultrasonic transducer Compatible transducers: ST-H and transducer and transceiver
EchoMax series XPS-10, XPS 15/15F, Displays and controls 100 x 40 mm (4 x 1.5 inch) multi-

4
and XRS-5 block LCD with backlighting
Relays Rating 5 A at 250 V AC, non-inductive Programming Programming using hand-held
• Version with 1 relay 1 SPST Form A programmer, SIMATIC PDM or via PC
(MultiRanger 100 only) with Dolphin Plus software
• Version with 3 relays 2 SPST Form A/1 SPDT Form C Power supply
• Version with 6 relays 4 SPST Form A/2 SPDT Form C • AC version 100 ... 230 V AC ± 15 %,
mA output 0 ... 20 mA or 4 ... 20 mA 50/60 Hz, 36 VA (17 W)
• Max. load 750 , isolated • DC version 12 ... 30 V DC (20 W)
• Resolution 0.1 % of range
Certificates and approvals • CE, RCM2)
Accuracy • Lloyd’s Register of Shipping
Error in measurement 0.25 % of range or 6 mm (0.24 inch), • ABS Type Approval
whichever is greater • FM, CSAUS/C, UL listed
0.1 % of measuring range1) • CSA Class I, Div. 2, Groups A, B, C
Resolution
or 2 mm (0.08 inch), whichever is and D, Class II, Div.2, Groups F and
greater G, Class III (wall mount only),
ATEX II 3D
Temperature compensation • -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor Communication • RS 232 with Modbus RTU or
• External TS-3 temperature sensor ASCII via RJ-11 connector
(optional) • RS 485 with Modbus RTU or
• Programmable fixed temperature ASCII via terminal strips
values • Optional: SmartLinx cards for
- PROFIBUS DP
Rated operating conditions - DeviceNet
Installation conditions 1)
Program range is defined as the empty distance to the face of the trans-
• Location Indoor/outdoor ducer plus any range extension
• Installation category II 2)
EMC performance available on request
• Pollution degree 4
Ambient conditions
• Ambient temperature (housing) -20 ... +50 °C (-4 ... +122 °F)

Siemens FI 01 · 2015 4/153


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200
Selection and Ordering data Article No. Selection and Ordering data Order code
MultiRanger 100/200 7ML5033- Further designs
Versatile short to medium-range ultrasonic single
7 7 7 77 - 77 Please add "-Z" to Article No. and specify Order
and multi-vessel level monitor/controller for virtually
any application in a wide range of industries code(s).

Click on the Article No. for the online configura- Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
tion in the PIA Life Cycle Portal. Measuring-point number/identification
(max. 27 characters) specify in plain text
Versions
Operating Instructions Article No.
MultiRanger 100, level measurement only ¢ 1
MultiRanger 200, level, volume, flow and differential ¢ 2 English 7ML1998-5FB06
measurements
French 7ML1998-5FB13
Mounting, enclosure design
Spanish 7ML1998-5FB23
Wall mount, standard enclosure ¢ A
Wall mount, 4 entries, 4 M20 cable glands included¢ B German 7ML1998-5FB36
Panel mount (CE, CSAUS/C, FM, UL) ¢ C Quick Start guide, multi-language 7ML1998-5QD83
Power supply Note: The Operating Instructions should be
100 ... 230 V AC ¢ A ordered as a separate item on the order.

4
This device is shipped with the Siemens Milltronics
12 ... 30 V DC ¢ B manual DVD containing the ATEX Quick Start and
Number of measurement points Operating Instructions library.
Single point version ¢ 0 Other Operating Instructions
Dual point version ¢ 1
SmartLinx PROFIBUS DP, English 7ML1998-1AQ03
Communication (SmartLinx)
Without module ¢ 0 SmartLinx PROFIBUS DP, German 7ML1998-1AQ33
SmartLinx PROFIBUS DP module ¢ 2 SmartLinx PROFIBUS DP, French 7ML1998-1AQ13
SmartLinx DeviceNet module ¢ 3 SmartLinx DeviceNet, English 7ML1998-1BH02
See SmartLinx product on page 4/360 for Note: The appropriate SmartLinx Operating
more information. Instructions should be ordered as a separate line
Output relays on the order.
3 relays (2 Form A, 1 Form C), 250 V AC ¢ 1 Accessories
6 relays (4 Form A, 2 Form C), 250 V AC ¢ 2 Handheld programmer 7ML1830-2AK
1 relay (1 Form A), 250 V AC ¢ 3
(available on MultiRanger 100 model only) Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
one text line, suitable for enclosure
Approvals
General Purpose CE, FM, CSAUS/C, ¢ A M20 cable gland kit (4 M20 cable glands, 7ML1930-1FV
UL listed, RCM 4 M20 nuts, 4 washers)
CSA Class I, Div. 2, Groups A, B, C and D; Class II, ¢ B Sunshield kit, 304 stainless steel 7ML1930-1GA
Div. 2, Groups F and G; Class III1)
ATEX II 3D2) ¢ C SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
1)
For wall mount applications only SITRANS RD200, universal input display with 7ML5740-...
2)
For standard enclosure wall mount, option A only Modbus conversion - see Chapter 7
¢ We can offer shorter delivery times for configurations designated with the SITRANS RD300, dual line display with totalizer 7ML5744-...
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
Spare parts
Power Supply Board (100 ... 230 V AC) 7ML1830-1MD
Power Supply Board (12 ... 30 V DC) 7ML1830-1ME
Display Board 7ML1830-1MF
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/154 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
MultiRanger 100/200

■ Dimensional drawings ■ Schematics


Wall mount version Mounting
14.9 holes See note 1 TB1
(0.58) 160.3 (6.325) Ø 4.3 91 6.6 TB1
(0.17) (x4) TB2
15.2 130 (5.125) (3.58) (0.26)
- L2/N L1
(0.6)
2 - +
+ 12 ... 30 V TB3
- SYNC
1
DC version

240 (9.45)
227 (8.93)
+ -
Cover
screws mA INPUT
(x6) +
SHIELD
Relay 1
-
1
4 ... 20 mA +
Relay 2 OUTPUTS
Housing -

4
Suitable location for 2
conduit entrances Mounting screw
(provided by customer) +
Siemens Milltronics Mounting holes Relay 3 +
recommends using a hole (accessed under lid) TS-3
punch for drilling the holes. Ø 4.3 (0.17) (x4) -
SHIELD
Panel mount version Relay 4 1
97
198 (7.80) (3.82) DISCRETE 2
36 INPUTS
(1.40) Relay 5

COM
Relay 6 RS 485 A
278 (10.94)

Relays shown in released B


state

Note:
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
MultiRanger, dimensions in mm (inch) 3. Connect all cable shields to the MultiRanger shield connections.
Avoid differential ground potentials by not connecting cable shields
to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.

MultiRanger connections

Siemens FI 01 · 2015 4/155


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200

■ Overview ■ Application
For water authorities, municipal water, and wastewater plants,
HydroRanger 200 is an economical, low-maintenance solution
delivering control efficiency and productivity needed to meet
today’s exacting standards. It offers single point monitoring with
all models, and optional dual-point monitoring with 6 relay
model. As well, it has digital communications with built-in
Modbus RTU via RS-485.
The standard 6 relay HydroRanger 200 will monitor open chan-
nel flow and features more advanced relay alarming and pump
control functions as well as volume conversion. It is compatible
with SIMATIC PDM, allowing for PC configuration and setup.
Sonic Intelligence advanced echo-processing software pro-
vides increased reading reliability. The optional 1 or 3 relay mod-
els provide accurate level measurement functions only; these
two models do not provide open channel flow, differential level
measurement or volume conversion functions.
4 HydroRanger 200 uses proven continuous ultrasonic echo rang-
ing technology to monitor water and wastewater of any consis-
HydroRanger 200 is an ultrasonic level controller for up to tency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 %
six pumps and provides control, differential control, and open with accuracy to 0.25 % of range. Unlike contacting devices,
channel flow monitoring. HydroRanger 200 is immune to problems caused by suspended
solids, harsh corrosives, grease or silt in the effluent, reducing
downtime.
■ Benefits • Key Applications: wet wells, flumes/weirs, bar screen control
• Monitors wet wells, weirs and flumes
• Digital communications with built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM config-
uration software
• Single or dual point level monitoring
• 6 relay (standard), 1 or 3 relay (optional)
• Auto False-Echo Suppression for fixed obstruction avoidance
• Anti-grease ring/tide mark buildup
• Differential amplifier transceiver for common mode noise
rejection and improved signal-to-noise ratio
• Wall and panel mounting options

4/156 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200

■ Technical specifications
Mode of Operation Design
Measuring principle Ultrasonic level measurement Weight
Measuring range 0.3 ... 15 m (1 ... 50 ft), • Wall mount 1.37 kg (3.02 lb)
transducer dependent • Panel mount 1.50 kg (3.31 lb)
Measuring points 1 or 2 Material (enclosure) Polycarbonate
Input Degree of protection (enclosure)
• Wall mount IP65/Type 4X/NEMA 4X
Analog 0 ... 20 mA or 4 ... 20 mA,
from alternate device, scalable • Panel mount IP54/Type 3/NEMA 3
(6 relay model) Cable
Discrete 10 ... 50 V DC switching level • Transducer and mA output signal 2-core copper conductor, twisted,
Logical 0  0.5 V DC shielded, 300 Vrms, 0.82 mm²
Logical 1 = 10 ... 50 V DC (18 AWG), Belden 8 760 or equivalent
Max. 3 mA is acceptable
Output • Max. separation between 365 m (1 200 ft)
transducer and transceiver
4
EchoMax transducer 44 kHz
Ultrasonic transducer Compatible transducers: ST-H and Displays and controls 100 x 40 mm (4 x 1.5 inch)
EchoMax series XPS-10, XPS 15/15F, multi-block LCD with backlighting
and XRS-5 Programming Programming using handheld
Relays1) Rating 5 A at 250 V AC, non-inductive programmer or via PC with
SIMATIC PDM software
• Model with 1 relay2) 1 SPST Form A
• Model with 3 relays2) 2 SPST Form A/1 SPDT Form C Power supply4)
• Model with 6 relays 4 SPST Form A/2 SPDT Form C AC version 100 ... 230 V AC ± 15 %, 5
mA output 0 ... 20 mA or 4 ... 20 mA 0/60 Hz, 36 VA (17 W)
• Max. load 750 , isolated DC version 12 ... 30 V DC (20 W)
• Resolution 0.1 % of range Certificates and approvals • CE, RCM5)
Accuracy • Lloyd's Register of Shipping
• ABS Type Approval
Error in measurement 0.25 % of range or 6 mm (0.24 inch), • FM, CSAUS/C, UL listed
whichever is greater • CSAUS/C Class I, Div. 2,
Groups A, B, C and D, Class II,
Resolution 0.1 % of measuring range or 2 mm
(0.08 inch), whichever is greater3) Div. 2, Groups F and G, Class III
(wall mount only)
Temperature compensation • -50 ... +150 °C (-58 ... +302 °F) • MCERTS Class 3 approved for
• Integral temperature sensor in trans- Open Channel Flow
ducer
• External TS-3 temperature sensor Communication • RS 232 with Modbus RTU or
(optional) ASCII via RJ-11 connector
• Programmable fixed temperature • RS 485 with Modbus RTU or
values ASCII via terminal blocks
• Optional: SmartLinx cards for
Rated operating conditions - PROFIBUS DP
- DeviceNet
Installation conditions
1)
• Location Indoor / outdoor All relays certified for use with equipment that fails in a state at or under the
rated maximums of the relays
• Installation category II 2)
This model is level control only; no open channel flow, differential level or
• Pollution degree 4 volume conversion functions
3)
Program range is defined as the empty distance to the face of the trans-
Ambient conditions
ducer plus any range extension
• Ambient temperature (enclosure) -20 ... +50 °C (-4 ... +122 °F) 4)
Maximum power consumption is listed
5)
EMC performance available upon request

Siemens FI 01 · 2015 4/157


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200
Selection and Ordering data Article No. Selection and Ordering data Order code
Siemens HydroRanger 200 7ML5034- Further designs
Ultrasonic level controller for up to six pumps that Please add "-Z" to Article No. and specify Order
777 77
provides control, differential control and open code(s).
channel flow monitoring. The HydroRanger 200 is
also available as a level measurement controller Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
only. Select option from number of measurement Measuring-point number/identification
points options below. (max. 27 characters) specify in plain text
Click on the Article No. for the online configura- Operating Instructions Article No.
tion in the PIA Life Cycle Portal. English 7ML1998-5FC03
Mounting French 7ML1998-5FC11
Wall mount, standard enclosure 1
Wall mount, 4 entries, 4 M20 cable glands included 2 German 7ML1998-5FC33
Note: The Operating Instructions should be
Panel mount1) 3 ordered as a separate item on the order.
Power supply This device is shipped with the Siemens Milltronics
100 ... 230 V AC A manual DVD containing the ATEX Quick Start and
Operating Instructions library.
12 ... 30 V DC B

4 Number of measurement points


Single point model, 6 relays A
Other Operating Instructions
SmartLinx PROFIBUS DP, English 7ML1998-1AQ03
Dual point model, 6 relays B SmartLinx PROFIBUS DP, German 7ML1998-1AQ33
Single point model, level only, 1 relay2) C SmartLinx PROFIBUS DP, French 7ML1998-1AQ13
Single point model, level only, 3 relays2) D
SmartLinx DeviceNet, English 7ML1998-1BH02
Communication (SmartLinx) Note: The appropriate SmartLinx Operating
Without module 0 Instructions should be ordered as a separate line
SmartLinx PROFIBUS DP module 2 on the order.
SmartLinx DeviceNet module 3 Accessories
See SmartLinx product on page 4/360 for Handheld programmer 7ML1830-2AK
more information.
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
Approvals one text line, suitable for enclosure
General Purpose CE, FM, CSAUS/C, UL listed, RCM 1
CSA Class I, Div. 2, Groups A, B, C, and D; 2 Sunshield kit, 304 stainless steel 7ML1930-1GA
Class II, Div. 2, Groups F and G; Class III SITRANS RD100, loop powered display - 7ML5741-...
(for wall mount applications only) see Chapter 7
1) Available with approval option 1 only SITRANS RD200, universal input display with 7ML5740-...
2) This model is level control only; no open channel flow, differential level, Modbus conversion - see Chapter 7
or volume conversion functions. SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
Spare parts
Power Supply Board (100 ... 230 V AC) 7ML1830-1MD
Power Supply Board (12 ... 30 V DC) 7ML1830-1ME
Display Board 7ML1830-1MF

4/158 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
HydroRanger 200

■ Dimensional drawings ■ Schematics


Wall mount version Mounting
14.9 holes See note 1 TB1
(0.58) 160.3 (6.325) Ø 4.3 91 6.6 TB1
(0.17) (x4) TB2
15.2 130 (5.125) (3.58) (0.26)
- L2/N L1
(0.6)
2 - +
+ 12-30 V TB3
- SYNC
1
DC version

240 (9.45)
227 (8.93)
+ -
Cover
screws mA INPUT
(x6) +
SHIELD
Relay 1
-
1
4 ... 20 mA +
Relay 2 OUTPUTS
Housing -

4
Suitable location for 2
conduit entrances Mounting screw
(provided by customer) +
Siemens Milltronics Mounting holes Relay 3 +
recommends using a hole (accessed under lid) TS-3
punch for drilling the holes. Ø 4.3 (0.17) (x4) -
SHIELD
Panel mount version Relay 4 1
97
198 (7.80) (3.82) DISCRETE 2
36 INPUTS
(1.40) Relay 5

COM
Relay 6 RS 485 A
278 (10.94)

Relays shown in released B


state

Notes
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft.). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
HydroRanger 200, dimensions in mm (inch) 3. Connect all cable shields to the HydroRanger 200 shield connec-
tions. Avoid differential ground potentials by not connecting cable
shields to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.

HydroRanger 200 connections

Siemens FI 01 · 2015 4/159


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02

■ Overview ■ Overview

4
The SITRANS LU01 is an ultrasonic long-range level controller The SITRANS LU02 is a dual point ultrasonic long-range level
for liquids and solids in a single vessel up to 60 m (200 ft). controller for liquids and solids in one or two vessels up to 60 m
Handheld programmer shown is an accessory and must be (200 ft). Handheld programmer shown is an accessory and must
ordered separately. be ordered separately.

■ Benefits ■ Benefits
• Single point, long-range level monitoring • Dual point, long-range level monitoring
• Easy to install; easy to program using removable infrared • Easy to install; easy to program using removable infrared
keypad (optional) keypad (optional)
• Compatible with all EchoMax transducers • Compatible with all EchoMax transducers
• Backlit LCD display with reading in standard engineering units • Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom • Automatic level-to-volume conversion for standard or custom
tank shapes tank shapes
• Dolphin Plus compatible • Dolphin Plus compatible
• High/low alarms • High/low alarms

■ Application ■ Application
The system consists of a SITRANS LU01 monitor linked to a non- SITRANS LU02 will measure liquids, solids or a combination of
contacting ultrasonic transducer that can be mounted up to both in one or two vessels of different sizes, shapes and config-
365 m (1 200 ft) away. The SITRANS LU01 will measure dis- urations up to 60 m (200 ft).
tance, level or volume, and it features patented Sonic Intelli-
gence echo processing software for superior reliability. The system uses ultrasonic technology to measure level, space,
distance, volume or average/differential. It features patented
Readings are displayed in user-selectable linear engineering Sonic Intelligence echo processing software for superior reliabil-
units on the backlit LCD. ity. Transducers can be mounted up to 365 m (1 200 ft) from the
monitor.
Modules for popular industrial buses can be factory installed or
added later to meet changing needs. No external gateway is Readings are displayed in user-selectable linear engineering
required, reducing hardware and cabling costs. units on the backlit LCD.
• Key Applications: chemical storage, liquid storage, • Key Applications: chemical storage, liquid storage,
bulk solids storage (gravel, flour bins, grains, cereals), bulk solids storage (gravel, flour bins, grains, cereals),
plastic pellets plastic pellets, tripper car

4/160 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02

■ Technical specifications Selection and Ordering data Article No.


SITRANS LU01/LU02 7ML5004-
Mode of operation
Single or dual point ultrasonic long-range level 777 77 77
Measuring principle Ultrasonic level measurement monitoring system for liquids and solids,
Measuring range 0.3 ... 60 m (1 ... 200 ft) and ranges up to 60 m (200 ft).
Measuring points SITRANS LU01: Max. one point; Click on the Article No. for the online configura-
SITRANS LU02 Max. two points tion in the PIA Life Cycle Portal.
Output signal Number of measuring points
Ultrasonic transducer EchoMax series, ST-H transducers LU01 version, 1 point 1
LU02 version, 2 points 2
Relays 4 SPDT Form C relays, rated at 5 A at
250 V AC, resistive load Input voltage
mA output 0/4 ... 20 mA, optically isolated 100/115/200/230 V AC, voltage selector switch A
18 ... 30 V DC B
• Max. load 750 , isolated, 30 V
Feature software
• Resolution 0.1 % of range
Standard A
• Outputs SITRANS LU01: Max. one mA output
Application software
4
SITRANS LU02: Max. two mA outputs
Standard 1
Accuracy
Data communications
Error in measurement 0.25 % of range or 6 mm (0.24 inch),
whichever is greater No module (SmartLinx ready) 0

Resolution 0.1 % of measuring range or 2 mm Enclosure


(0.08 inch), whichever is greater Wall mount 1
Temperature compensation -50 ... +150 ºC (-58 ... +302 ºF)
Wall mount, drilled, 6 x M20 3
• Integral temperature sensor Note: Cable glands are not included and should be
• External TS-3 temperature sensor ordered as a separate line on the order.
(optional) Approvals
• Programmable fixed temperature
CE, CSAUS/C, FM1) A
Rated operating conditions CE B
Ambient conditions ATEX II 3D2) C
Ambient temperature for enclosure -20 ... +50 ºC (-4 ... +122 ºF) 1)
Available with enclosure option 1 only
2)
Design Available with enclosure option 3 only
Weight 2.7 kg (6 lb)
Material (enclosure) Polycarbonate
Degree of protection (wall mount) IP65
Electrical connection
Ultrasonic transducer cable extension RG62-A/U coaxial cable with low
capacitance
mA output signal 2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden8 760 or
equivalent is acceptable
Electrical connection and relay Copper conductor according to local
connection requirements, rated 250 V
5A
Synchronization Up to 16 LU01/LU02 units can be
synchronized together
Power supply
AC model 100/115/200/230 V AC ± 15 %,
50/60 Hz, 31 VA
DC model 18 ... 30 V DC, 25 W
Displays and controls 51 x 127 mm (2 x 5 inch) graphics
LCD with backlighting
Memory EEPROM (non-volatile), no backup
battery required
Programming Using removable programmer
(ordered separately) or
Dolphin Plus (option)
Certificates and approvals CE, CSAUS/C, FM, ATEX II 3D
Lloyd's register of Shipping
(Categories ENV1, ENV2, ENV3 and
ENV5)
Options
External temperature sensor TS-3
Communications • Dolphin Plus: Siemens Windows-
compatible interface and
ComVerter link (infrared)

Siemens FI 01 · 2015 4/161


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Accessories
Please add "-Z" to Article No. and specify Order Handheld programmer 7ML1830-2AN
code(s).
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 one text line, suitable for enclosures
Measuring-point number/identification
(max. 27 characters) specify in plain text M20 cable gland kit (6 M20 cable glands, 7ML1830-1GM
6 M20 nuts, 3 stop plugs)
Operating Instructions Article No.
SITRANS LU01 M20 cable gland kit (4 M20 cable glands, 7ML1930-1FV
4 M20 nuts, 4 washers)
English 7ML1998-5BE02 TS-3 Temperature Sensor - see TS-3 on page 4/189 7ML1830-2AN
French 7ML1998-5BE12 Sunshield kit, 304 stainless steel 7ML1930-1GA
German 7ML1998-5BE32 Spare parts
SITRANS LU02 Card, LU01 mother main, AC, comm ready 7ML1830-1KX
English 7ML1998-5BD02 Card, LU02 mother main, AC, comm ready 7ML1830-1MA

4
French 7ML1998-5BD12 Card, LU02 daughter, comm ready 7ML1830-1LP
German 7ML1998-5BD32 Card, LU01 daughter, comm ready 7ML1830-1LN
Note: The Operating Instructions should be
ordered as a separate line item. Card, display 7ML1830-1LQ
This device is shipped with the Siemens Milltronics See SmartLinx product page 4/360 for
manual DVD containing the ATEX Quick Start and more information.
Operating Instructions library.

■ Dimensional drawings
285 (11.2) 106 285 (11.2) 106
(4.2) (4.2)
267 (10.5) 92 267 (10.5) 92
(3.6) (3.6)

100 100
% %
209 (8.2)
209 (8.2)

1 2 3 4 1 2 3 4
172 (6.8)

0
172 (6.8)

1 2 3 4 1 2 3 4

5 6 7 8 5 6 7 8
mA mA

9 0 9 0
P P P P XX
XX

C % C %

SITRANS LU 01 SITRANS LU 02

Mounting hole Mounting hole


Suitable location for conduit entrances. Use 4.3 (0.17) diameter Suitable location for conduit entrances. Use 4.3 (0.17) diameter
water-tight conduit hubs to maintain enclosure access under lid water-tight conduit hubs to maintain enclosure access under lid
rating. (4 places) rating. (4 places)

Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right), dimensions in mm (inch)

4/162 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU01 and LU02

■ Schematics
AC model
Note 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
+ – + –
WHT/SHLD
BLK

BLK
WHT/SHLD

BLK

WHT/SHLD

BLK

WHT/SHLD
1 2 1 2

SYNC
L2/N L1

SHLD

SHLD
1 2 TX RX
Position SW1
Bi-polar current loop
mA 1 2 3 4 TX RX for 100/115/
1 2

SHLD

SHLD
outputs 200/230 V AC

COM
Temp. Temp. Relays
1 2 sensor sensor Operation
Note 1 Note 3 RS 232 (50/60 Hz
B A

SHLD

SHLD
Note 2 31 VA)

COM
RS-485
RS 485

DC model
Note 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
+ – + –
4
WHT/SHLD
BLK

BLK
WHT/SHLD

BLK

WHT/SHLD

BLK

WHT/SHLD

1 2 1 2

SYNC
– +

SHLD

SHLD
1 2 TX RX 24 V
Bi-polar current loop
mA 1 2 3 4 TX RX
1 2

SHLD

SHLD
outputs

COM
Temp. Temp. Relays
1 2 sensor sensor
Note 1 Note 3 RS 232
B A

SHLD

SHLD
Note 2

COM
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5mm 2) wire.

SITRANS LU01 connections

AC model
Note 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
+ – + –
WHT/SHLD
BLK

BLK
WHT/SHLD

BLK

WHT/SHLD

BLK

WHT/SHLD

1 2 1 2
SYNC

L2/N L1
SHLD

SHLD

1 2 TX RX
Position SW1
Bi-polar current loop
mA 1 2 3 4 TX RX for 100/115/
1 2
SHLD

SHLD

outputs 200/230 V AC
COM

Temp. Temp. Relays


1 2 sensor sensor Operation
Note 1 Note 3 RS-232 (50/60 Hz
B A
SHLD

SHLD

Note 2 31 VA)
COM

RS-485

DC model
Note 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
+ – + –
WHT/SHLD
BLK

BLK
WHT/SHLD

BLK

WHT/SHLD

BLK

WHT/SHLD

1 2 1 2
SYNC

– +
SHLD

SHLD

1 2 TX RX 24 V
Bi-polar current loop
mA 1 2 3 4 TX RX
1 2
SHLD

SHLD

outputs
COM

Temp. Temp. Relays


1 2 sensor sensor
Note 1 Note 3 RS-232
B A
SHLD

SHLD

Note 2
COM

RS-485

Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5 mm 2) wire.

SITRANS LU02 connections

Siemens FI 01 · 2015 4/163


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10

■ Overview ■ Benefits
• Ten point, long-range level monitoring
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus compatible
• Backlit LCD display with reading in standard engineering units
• Easy to install, easy to program using removable infrared
keypad (optional)

■ Application
It can be used in a wide range of applications to scan liquids,
solids or a combination of both contained in vessels of differing
size, shape, and configuration up to 60 m (200 ft).
SITRANS LU10 uses ultrasonic technology to measure level,

4
space, distance, volume, or average/differential. Transducers
can be mounted up to 365 m (1 200 ft) from the monitor.
The SITRANS LU10 features patented Sonic Intelligence echo
processing software for superior reliability. Readings are dis-
SITRANS LU10 is an ultrasonic long-range level monitor for played in user-selectable linear engineering units on the LCD.
liquids and solids, offering 10-point monitoring in a single unit.
Handheld programmer shown is an accessory and must be • Key Applications: chemical storage, liquid storage, bulk
ordered separately. solids storage (sugar, flour bins, grains, cereals), plastic
pellets, tank farms

4/164 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10

■ Technical specifications
Mode of operation Power supply 100/115/200/230 V AC ± 15 %,
50/60 Hz, 31 VA
Measuring principle Ultrasonic level measurement
Displays and controls 51 x 127 mm (2 x 5 inch) graphics
Measuring range Max. 0.3 ... 60 m (1 ... 200 ft) LCD with backlighting
Measuring points Max. 10 Memory EEPROM (non-volatile), no backup
Output battery required

Ultrasonic transducer EchoMax series, ST-H transducers Programming Using removable programmer
(ordered separately) or Dolphin Plus
Relays SPDT Form C relays, rated 5 A at (option)
250 V AC, resistive load
Certificates and approvals • CE, RCM, FM, CSAUS/C , ATEX II 3D
mA output SITRANS LU A0 module (option): • Lloyd's register of Shipping
0/4 ... 20 mA, optically isolated (Categories ENV1, ENV2, ENV3 and
ENV5)
• Max. load 750 , isolated
Options
• Resolution 0.1 % of range
Expansion card TIB-9, increases the number of
Accuracy

4
TS-3 inputs from 1 ... 10
Error in measurement 0.25 % of range or 6 mm (0.24 inch), • External temperature sensor TS-3
whichever is greater • Communications • Dolphin Plus: Siemens Windows-
Resolution 0.1 % of measuring range or 2 mm compatible interface and
(0.08 inch), whichever is greater ComVerter link (infrared)
• I/O devices • Max. 3 I/O devices per
Temperature compensation -50 ... +150 °C (-58 ... +302 °F) SITRANS LU10
• Integral temperature sensor • SITRANS LU AO analog output
• External TS-3 temperature sensor module (max. 1)
(expandable to 10 inputs with
optional TIB-9 card)
• Programmable fixed temperature
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure -20 ... +50 °C (-4 ... +122 °F)
Design
Weight 2.7 kg (6 lb)
Material (enclosure) Polycarbonate
Degree of protection (wall mount) IP65/Type 4X/NEMA 4X
Electrical connection
Ultrasonic transducer RG62-A/U coaxial cable with low
capacitance
Signal transmission 2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
Electrical connection and relay Copper conductor according to local
connection requirements, rated 250 V 5 A
Synchronization Up to 16 LU10 units can be synchro-
nized together

Siemens FI 01 · 2015 4/165


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LU10 7ML5007- Further designs
Ten point ultrasonic long-range level monitoring 7 7 7 7 7 - 77
system for liquids and solids applications, Please add "-Z" to Article No. and specify Order
code(s).
and ranges up to 60 m (200 ft).
Click on the Article No. for the online configura- Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
tion in the PIA Life Cycle Portal. (max. 27 characters) specify in plain text
Input voltage
Operating Instructions Article No.
100/115, 200/230 V AC, selectable 1
Feature software English 7ML1998-5AN02
Standard A French 7ML1998-5AN12
Application software German 7ML1998-5AN32
Standard A
Accessories
Data communications
No module (SmartLinx ready) 0 Handheld programmer 7ML1830-2AN
TIB-9 temperature card Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), 7ML1930-1AC
None 0 one text line, suitable for enclosures

4 With TIB-9 card


Enclosure
1
Temperature Card TIB 9-card 7ML1830-1CN

Wall mount 1 M20 cable gland kit (6 M20 cable glands, 7ML1830-1GM
6 M20 nuts, 3 stop plugs)
Wall mount, drilled, 12 x M20 x1.5 for cable glands 2
Note: Cable glands are not included and should be M20 cable gland kit (4 M20 cable glands, 7ML1930-1FV
ordered as a separate line on the order. 4 M20 nuts, 4 washers)
Approvals TS-3 Temperature Sensor - see TS-3 on page 4/189
CE, CSAUS/C, FM1) A
B Sunshield kit, 304 stainless steel 7ML1930-1GA
ATEX II 3D1)
CE, RCM2) D Spare parts
Card, mother main, AC, comm ready 7ML1830-1ML
1)
Available with enclosure option 1 only
2) Card, daughter, comm ready 7ML1830-1LY
Available with enclosure option 2 only
Card, display 7ML1830-1LQ
See SmartLinx product on page 4/360 for more
information.

4/166 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU10

■ Dimensional drawings
285 (11.2) 106
(4.2)
267 (10.5) 92
(3.6)

100
%
209 (8.2)

1 2 3 4 5 6 7 8 9 10
172 (6.8)

1 2 3 4

5 6 7 8
mA

9 0
P P XX

C %

SITRANS LU 10

Mounting hole
Suitable location for conduit entrances. Use 4.3 (0.17) diameter
water-tight conduit hubs to maintain enclosure
rating.
access under lid
(4 places) 4
SITRANS LU10, dimensions in mm (inch)

■ Schematics
2 3 9 10
white/shield

white/shield

white/shield

white/shield
black

black

black

black

1 2 3 4 18 19 20 21 22 23 24 25 26 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52
white/shield

white/shield

white/shield

white/shield

white/shield

SYNC
black

black

black

black

black

1 2 1 2 P12 L2/N L1
V
TX RX
Position SW1
Peripheral for 100/115/
communication 200/230 V
Temp.
sensor AC
1 2 9 10 2 3 9 10 Note 3 Operation
transducers (50/60 Hz,
Note 1 Note 2 15 VA)
To transducers (10 max.) RG62-A/U
coax, 365 m / transducer max.

Notes:
1. Transducer cables must be run in a grounded metal conduit separate from other wiring (except TS-3 temperature sensor wiring, if
applicable).
2. Optional TIB-9 card for multiple temperature sensors. Do not jump the terminals if TS-3s are not used.
3. The SITRANS LU10 is compatible with the following Siemens Milltronics peripherals:
- SITRANS LU AO - analog output module

SITRANS LU10 connections

Siemens FI 01 · 2015 4/167


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU AO

■ Overview ■ Technical specifications


Mode of operation
Input
Communications Data from SITRANS LU10
Transmission rate 4 800 bits/s
Voltage ± 20 mA bipolar current loop
Polarization Non-polarized
Max. load 1 receiving unit
Output
Analog outputs 10 analog outputs, programmable
from SITRANS LU10
0 or 4 ... 20 mA, isolated
± 20 mA bipolar current loop Input and transmission
• Max. load 750 
• Resolution 0.1 %
Rated operating conditions
4 Ambient conditions
Ambient temperature for enclosure -20 ... +50 °C (-5 ... +122 °F)
The SITRANS LU AO Analog Output Module provides remote Location Indoor/outdoor
analog output for the measurement points of the SITRANS LU10 Installation category II
level monitor. Pollution degree 4
Design
■ Benefits Weight 2 kg (4.4 lb)
• Analog outputs can be up to 1 500 m (5 000 ft) from the Material (enclosure) Polycarbonate
SITRANS LU 10 Degree of protection Type 4X/NEMA 4X/IP65
• Analog outputs can be per transducer and/or average of 2 or Cable connection 2 copper conductors, twisted,
more with foil shield/drain wire, 300 V
0.5 ... 0.75 mm² (22 ... 18 AWG)
Electrical connection and relay Copper conductor according to
■ Application connection local requirements,
rated 250 V 5 A
The operation of the SITRANS LU AO is programmed via the
SITRANS LU10. The only on-board settings are for bank selec- Power supply 100/115/200/230 V AC ± 15 %,
tion and output testing. 50/60 Hz, 15 VA
Displays and controls 1 LED for display of voltage/
The SITRANS LU AO can provide up to 10 analog outputs communications state
(each sharing a common negative bus which is electrically
isolated from ground). Certificates and approvals CE, FM, CSAUS/C , RCM

Selection and Ordering data Article No.


SITRANS LU AO 7ML5810-1A
Provides remote analog output for the
measurement points of the SITRANS LU10
level monitor.
Approvals: CSAUS/C, FM, CE, RCM
Operating Instructions
English 7ML1998-5CE01
German 7ML1998-5CE31
Note: Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the Quick Start and Opera-
ting Instructions library.
Accessories
Sun Shield, 304 stainless steel 7ML1930-1GA

4/168 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic controllers
SITRANS LU AO

■ Dimensional drawings
209
16 (8.2)
(0.6)
91
Lid screws
172 (3.6)
(6 places)
(6.8)

267 285
(10.5) (11.2)
4
SITRANS LU AO

Suitable location for Lid


Mounting holes conduit entrances
(accessed under lid) Enclosure
4.3 mm (0.17 inch) diameter
4 places Mounting screw (by customer)

SITRANS LU AO, dimensions in mm (inch)

■ Schematics
230 V 200 V
OFF
Switch is shown in OFF position.
Select appropriate voltage.
115 V

100 V SW3
See note 1 See note 2

Bi-polar mA mA mA mA mA
Receiver output output output output output
spare

1_ 2_ 3_ 4_ 5_ 6_ 7_ 8_ 9_ 10_ L2
+ + + + + + + + + + /N L1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

See note 3

Isolated 0/4 ... 20 mA out,


750 Ω load max. (typical of 10) 100/115/200/230 V AC
50/60 Hz select
voltage via switch

Notes:
1. SITRANS LU AO receiver input is non-polarized.
2. Refer to associated application device instruction manual for wiring detail. Check that the communication parameter P740 (SITRANS LU10) is ON.
3. SITRANS LU AO interconnecting cable shield should be grounded at SITRANS LU10 only. Insulate shields at junctions to prevent inadvertent
grounding. Maximum individual loop length is 3 000 m (10 000 ft).

SITRANS LU AO connections

Siemens FI 01 · 2015 4/169


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
Ultrasonic transducers

■ Overview
Ultrasonic Transducers
Ultrasonic measuring systems are the cost-effective choice for
monitoring and control in short- to long-range applications for
liquids, slurries, and solids in a wide range of industries. Trans-
ducers are impervious to dust, moisture, corrosion, vibration,
flooding, and extreme temperature. They are easy to install and
virtually maintenance-free. Choose from a wide selection of
models designed for short or long range applications on liquids
or solids.

■ Technical specifications
EchoMax Transducers
Liquids Liquids and Solids
Standard
4 XRS-5 ST-H XPS-10 XPS-15 XPS-30
Max. range1) 8m 10 m 10 m 15 m 30 m
(26 ft) (33 ft) (33 ft) (50 ft) (100 ft)
Min. range 0.3 m 0.3 m 0.3 m 0.3 m 0.6 m
(1 ft) (1 ft) (1 ft) (1 ft) (2 ft)
Max. temperature 65 °C 73 °C 95 °C 95 °C 95 °C
(149 °F) (164 °F) (203 °F) (203 °F) (203 °F)
Min. temperature -20 °C -40 °C -40 °C -40 °C -40 °C
(-4 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F)
Typical Applications Wet wells and open Chemical storage and Dusty solids and slurries Deep wet wells and Powders, pellets and
channels liquid tanks solids solids
Frequency 44 kHz 44 kHz 44 kHz 44 kHz 30 kHz
Beam angle (-3dB) 10° 12° 12° 6° 6°

Thread size R 1" [(BSPT), 1" and 2" NPT R 1" [(BSPT), R 1" [(BSPT), R 1.5" [(BSPT),
EN 10226] R 2" [(BSPT), EN 10226] EN 10226] EN 10226]
1" NPT EN 10226], 1" NPT 1" NPT Universal thread
2" [(BSPP), 1.5" NPT
EN ISO 228-1]

Enclosure • PVDF Copolymer • ETFE • PVDF • PVDF • PVDF


• CSM • Option: PVDF • Option: Foam facing • Option: Foam facing • Option: Foam facing
• Option: Flange with • Flange with PTFE facing • Flange with PTFE facing • Flange with PTFE facing
PTFE facing

Compatible with:
SITRANS LUT400 • • • • •

SITRANS LU • • • • •

HydroRanger 200 • • • •

MultiRanger 100/200 • • • •

1)
Application conditions such as extreme dust or angle of repose may reduce the usable maximum range.
Consult your local Siemens representative for further information.

4/170 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic transducer
Input
Measuring range 0.3 ... 10 m (1 ... 33 ft)
Output
Frequency 44 kHz
Beam angle 12°
Accuracy
Temperature compensation Compensated by integral
temperature sensor
Rated operating conditions
Pressure Normal atmospheric pressure

4
Ambient conditions
• Ambient temperature -20 ... +60 °C (-5 ... +140 °F)
(ATEX approved model)
-40 ... +73 °C (-40 ... +163 °F)
ST-H transducers use ultrasonic technology to measure level in (CSA/FM approved model)
chemical storage and liquid tanks. Design
Weight1) 1.4 kg (3 lb)
■ Benefits Material (enclosure) Base and lid made of ETFE or PVDF
• Can be mounted on a narrow standpipe (epoxy fitted joint)2)
• Immune to corrosive and harsh environments Process connection 2" NPT [(Taper), ANSI/ASME B1.20.1],
R 2" [(BSPT), EN 10226] or
• Integral temperature sensor G 2" [(BSPP), EN ISO 228-1]

■ Application Degree of protection


Cable connection
IP68
2-core shielded/twisted, 0.519 mm²
The narrow design of the ST-H allows the transducer to be (20 AWG), PVC sheath
mounted on a narrow standpipe. When mounted correctly, it is Cable (max. length) 365 m (1 200 ft) with RG 62 A/U
completely protected from the process and can even be used in coaxial cable
harsh, corrosive environments. Options
During operation, the ultrasonic transducer emits acoustic • Flange adapter 3" Universal (fits DN 65, PN 10 and
pulses in a narrow beam perpendicular to the transducer face. 3" ASME)
The level transceiver measures the propagation time between Certificates and approvals CE, CSA Class I, II, III, Div. 1,
pulse emission and reception of the echo to calculate the dis- Groups A, B, C, D, E, F, G T3
tance from the transducer to the material. Variations in sound (ETFE only), FM Class I, II, Div. 1,
Groups C, D, E, F, G T4A,
velocity due to changes in temperature within the permissible ATEX II 2G / INMETRO Ex mb IIC T5
range are automatically compensated by the integral tempera- Gb, RCM, KCC
ture sensor. 1)
Approximate shipping weight of transducer with standard cable length
• Key Applications: chemical storage, liquid tanks 2)
When measuring chemicals, check compatibility of ETFE or PVDF and
epoxy, or mount joint external to process.

Siemens FI 01 · 2015 4/171


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H
Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax ST-H ultrasonic transducer 7ML1100- Further designs
Level measurement in chemical storage and liquid 77 A 7 0 Please add "-Z" to Article No. and specify Order
tanks. The narrow design of the ST-H allows the code(s).
transducer to be mounted on a 2 inch standpipe.
Measuring range: min. 0.3 m (1 ft), max. 10 m Acrylic coated, stainless steel tag [13 x 45 mm Y17
(33 ft). (0.5 x 1.75 inch)]: Measuring-point number/
identification (max. 16 characters) specify in
Click on the Article No. for the online configura- plain text
tion in the PIA Life Cycle Portal.
Accessories Article No.
Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1] 0 Universal box bracket, mounting kit 7ML1830-1BK
ETFE, R 2" [(BSPT), EN 10226] 1 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange 7ML1830-1BT
ETFE, G 2" [(BSPP), EN ISO 228-1] 2 adapter for 2" NPT
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME 3 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange 7ML1830-1BU
B1.20.1] adapter for 2" BSPT
PVDF copolymer, R 2" [(BSPT), EN 10226] 4 Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] 5
4
Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX
Cable length 1" and 1½" BSPT aluminum couplings
5 m (16.40 ft) A Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
10 m (32.81 ft) B
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
30 m (98.43 ft) C 1½" BSPT 304 stainless steel couplings
50 m (164.04 ft) D
100 m (328.08 ft) E
Approvals
CE, FM Class I, II, Div. 1, Groups C,D,E,F,G T4A 2
ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM, KCC 3
CSA Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G T3
CE, ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM, 4
KCC
Operating Instructions Article No.
Quick Start Manual, multi-language A5E32105880
Applications Guidelines, multi-language 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
1)
Available with Process connection options 0 ... 2 only
2)
Available with Process connection options 3 ... 5 only
3)
Not suitable for Ketone, Hexane, Ester or Ethyl Acetate atmospheres

4/172 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
ST-H

■ Dimensional drawings
1" NPT Flange Adapter
Conduit Coupling

(0.87)
thread

22
Siemens Milltronics

119 (4.7)
Mounting thread flange adapter

(0.82)
20.9
(process

74 (2.9)
connection)

87 (3.4)
Diameter

82 (3.2)
4
ST-H ultrasonic transducer, dimensions in mm (inch)

■ Schematics
Direct connection

Black
White

Shield

Coaxial extension

White
Shield

3 Terminal direct*

Black
White
Shield

3 Terminal extension*
Black
White
Shield

* For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200

ST-H ultrasonic transducer connections

Siemens FI 01 · 2015 4/173


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic transducer
Input
Measuring range 0.3 ... 8 m (1 ... 26 ft), dependent on
application
Output
Frequency 44 kHz
Beam angle 10°
Accuracy
Temperature error Compensated by integral
temperature sensor
Rated operating conditions
Vessel pressure Normal atmospheric pressure

4 Ambient conditions
• Ambient temperature -20 ... +65 °C (-4 ... +149 ° F)
Design
EchoMax XRS-5 ultrasonic transducer provides reliable, contin-
uous level monitoring of liquids and slurries in narrow lift stations/ Weight (approximate shipping weight 1.2 kg (2.6 lb)
of sensor with standard cable length)
wet wells, flumes, weirs and filter beds using a beam angle of
just 10° and a CSM rubber face. Material (enclosure) PVDF copolymer enclosure and
CSM face

■ Benefits Process connection 1" NPT [(Taper), ANSI/ASME B1.20.1]


or R 1" [(BSPT), EN 10226]
• Narrow beam angle of only 10° Degree of protection IP65/IP68
• Chemically resistant PVDF copolymer enclosure and CSM Cable connection 2-core shielded/twisted, 0.5 mm2
rubber face (20 AWG), PVC sheath
• Measuring range: 8 m (26 ft) for measurement of liquids and Cable (max. length) • 365 m (1 200 ft) with RG 62 A/U
slurries coaxial cable
• 365 m (1 200 ft) with 2-core twisted
• Fully submersible: IP68 degree of protection pair, foil shield, 0.5 mm2
• Easy installation with 1" NPT or R 1" BSPT connection (20 AWG), PVC sheath, only for
MultiRanger 100/200

■ Application Options
Flange version Factory flange with PTFE face for
The XRS-5 is non-contacting with a measuring range from ASME, EN or JIS configuration
0.3 ... 8 m (1 ... 26 ft). Advanced echo processing ensures reli-
Submergence shield For applications with flooding possi-
able data even in conditions with obstructions, turbulence and ble
foam.
Certificates and approvals CE, RCM, KCC
The hermetically sealed CSM rubber face and the PVDF copoly- CSA Class I, Div. 2, Groups A,B,C,D,
mer enclosure are designed for maximum resistance to meth- Class II, Div. 1 Groups E,F,G
ane, salt water, caustics and harsh chemicals common to waste- FM Class I, Zone 1, AEx m IIC, T6
water installations. With an IP68 degree of protection, this Class II, III, Div. 1, Groups E,F,G T6
rugged sensor is fully submersible in the event of flood condi- ATEX II 2GD / IECEx / INMETRO
tions. Use a submergence shield if full submergence is possible Ex mb IIC T6 Gb, Ex tb IIIC T85 °C
in the application. A submergence shield will maintain a high Db
level reading output during submerged conditions.
The low-cost XRS-5 transducer is compatible with a full range of
Siemens controllers, from a basic system for high/low alarm or
simple pump control, up to advanced control systems with com-
munications, telemetry and SCADA integration capabilities.
• Key Applications: wet wells, flumes, weirs, filter beds

4/174 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5

Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax XRS-5 transducer 7ML1106- Further designs
With a beam angle of 10°, the XRS-5 provides 777 7 0 - 0 7 Please add "-Z" to Article No. and specify Order
reliable, continuous level monitoring of liquids and code(s).
slurries in narrow lift stations/wet wells, flumes, Acrylic coated, stainless steel tag [13 x 45 mm ¢ Y17
weirs and filter beds. (0.5 x 1.75 inch)]: Measuring-point number/
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft) identification (max. 16 characters) specify in
Click on the Article No. for the online configura- plain text
tion in the PIA Life Cycle Portal. Accessories Article No.
Process connection
Tag, stainless steel with hole, 7ML1930-1BJ
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 1 12 x 45 mm (0.47 x 1.77 inch),
R 1" [(BSPT), EN 10226] ¢ 2 one text line for fastening on sensors
Cable length
Submergence shield kit 7ML1830-1BH
5 m (16.40 ft) ¢ A
10 m (32.81 ft) ¢ B Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
30 m (98.43 ft) C
Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX
Facing 1" and 1½" BSPT aluminum couplings

4
Standard (CSM rubber) ¢ A
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
PTFE (flange versions) B
Approvals Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
CE, RCM, KCC, CSA Class I, Div. 2, Groups ¢ 2 1½" BSPT 304 stainless steel couplings
A,B,C,D, Class II, Div. 1 Groups E,F,G FMS-200 universal box bracket, mounting kit 7ML1830-1BK
FM Class I, Zone 1, AEx m IIC, T6 Class II, III, Div.
1, Groups E,F,G T6 ATEX II 2GD / IECEx / FMS-210 channel bracket, wall mount 7ML1830-1BL
INMETRO Ex mb IIC T6 Gb, Ex tb IIIC T85 °C Db FMS-220 extended channel bracket, wall mount 7ML1830-1BM
Mounting flange (flush mount)
FMS-310 channel bracket, floor mount 7ML1830-1BN
None ¢ A
3" ASME, 150 lb, flat faced B FMS-320 extended channel bracket, floor mount 7ML1830-1BP
4" ASME, 150 lb, flat faced C FMS-350 bridge channel bracket, floor mount 7ML1830-1BQ
6" ASME, 150 lb, flat faced D (see Mounting Brackets on page 4/187 for
DN 80, PN 10/16, Type A, flat faced J more information)
DN 100, PN 10/16, Type A, flat faced K 1" NPT locknut, plastic 7ML1830-1DS
DN 150, PN 10/16, Type A, flat faced L
1" BSPT locknut, plastic 7ML1830-1DR
JIS10K 3B style Q
JIS10K 4B style R ¢ We can offer shorter delivery times for configurations designated with the
JIS10K 6B style S Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.
Operating Instructions Article No.
Quick Start Manual, multi-language A5E32299685
Applications Guidelines, multi-language 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/175


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5

Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax XRS-5C transducer 7ML1105- Further designs
With a beam angle of 10°, the XRS-5 provides 777 7 1 - 0 7 Please add "-Z" to Article No. and specify Order
reliable, continuous level monitoring of liquids and code(s).
slurries in narrow lift stations/wet wells, flumes, Acrylic coated, stainless steel tag [13 x 45 mm ¢ Y17
weirs and filter beds. (0.5 x 1.75 inch)]: Measuring-point number/
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft) identification (max. 16 characters) specify in
Click on the Article No. for the online configura- plain text
tion in the PIA Life Cycle Portal. Accessories Article No.
Process connection
Submergence shield kit 7ML1830-1BH
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 1
Cable length Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
5 m (16.40 ft) ¢ A Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
10 m (32.81 ft) ¢ B
30 m (98.43 ft) C FMS-200 universal box bracket, mounting kit 7ML1830-1BK

Facing FMS-210 channel bracket, wall mount 7ML1830-1BL


Standard (CSM rubber) ¢ A FMS-220 extended channel bracket, wall mount 7ML1830-1BM

4
PTFE (flange versions) B
FMS-310 channel bracket, floor mount 7ML1830-1BN
Approvals
CSA Class I Div. 1, Group A,B,C,D; Class II Div. 1, ¢ 1 FMS-320 extended channel bracket, floor mount 7ML1830-1BP
Group E,F,G; Class III FMS-350 bridge channel bracket, floor mount 7ML1830-1BQ
Mounting flange (flush mount) (see Mounting Brackets on page 4/187 for
None ¢ A more information)
3" ASME, 150 lb, flat faced B ¢ We can offer shorter delivery times for configurations designated with the
4" ASME, 150 lb, flat faced C Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
6" ASME, 150 lb, flat faced D
Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.
Operating Instructions Article No.
Quick Start Manual, multi-language A5E32299685
Applications Guidelines, multi-language 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/176 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XRS-5

■ Dimensional drawings ■ Schematics


Standard Submergence Shield Direct connection
(optional)
White/shield
Black/hot
25
(0.98)
127 (5.0)

Black

155 (6.1)
White

Shield

89 (3.5)
Coaxial extension
Flange (optional)
124 (4.9)
Junction box 4
127 (5.0)

Extend cable using RG-62 A/U coax.

3 terminal direct*
ANSI, DIN, or JIS

Mounting: Bracket
Suspended Conduit
Black
Rigid metal Flexible White
conduit conduit
Steel
channel Shield
Non-metallic
coupling

Non-metallic 3 terminal extension*


coupling
Black
White
Transducer

Shield

Flexible conduit transducer should not be * For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200
subjected to wind, vibration or jarring.

Plywood
XRS-5 ultrasonic transducer connections
Submersible

Rigid metal
Non-metallic conduit
coupling
Non-metallic
coupling

Submergence
shield
Plywood mounting provides
excellent isolation
(must be rigid).
Transducer with submergence shield, used in
applications where flooding is possible.

XRS-5 ultrasonic transducer, dimensions in mm (inch)

Siemens FI 01 · 2015 4/177


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS

■ Overview ■ Benefits
• Integral temperature compensation
• Low ringing effect reduces blanking distance
• Optional foam facing for dusty applications
• Self-cleaning and low-maintenance
• Chemically resistant
• Hermetically sealed

■ Application
XPS transducers can be fully immersed, are resistant to steam
and corrosive chemicals, and can be installed without flanges.
The XPS series offers versions for various measuring ranges up
to 30 m (100 ft) and up to a max. temperature of 95 °C (203 °F).

4
During operation, the EchoMax transducers emit acoustic
pulses in a narrow beam. The level monitor measures the prop-
agation time between pulse emission and its reflection (echo) to
calculate the distance.
EchoMax XPS transducers use ultrasonic technology to mea-
sure level in a wide range of liquids and solids.

4/178 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS

■ Technical specifications
Input XPS-10 XPS-15 (standard and F models) XPS-30
Measuring range 0.3 ... 10 m Standard: 0.6 ... 30 m
(1 ... 33 ft) 0.3 ... 15 m (2 ... 100 ft)
(1 ... 50 ft)
XPS-15F:
0.45 ... 15 m
(1.5 ... 50 ft)
Output
Frequency 44 kHz 44 kHz 30 kHz
Beam angle 12° 6° 6°
Environmental
Location Indoors/outdoors
Ambient temperature -40 ... +95 °C XPS-15F: -40 ... +95 °C
(-40 ... +203 °F) -20 ... +95 °C
(-4 ... +203 °F)
(-40 ... +203 °F)
4
Pollution degree 4
Pressure 8 bar g (120 psi g) 8 bar g (120 psi g) 0.5 bar g (7.25 psi g)
Flanged: Flanged: Flanged:
0.5 bar g (7.25 psi g) 0.5 bar g (7.25 psi g) 0.5 bar g (7.25 psi g)
Design
Weight 0.8 kg 1.3 kg (2.8 lb) 4.3 kg
(1.8 lb) Flanged: (9.5 lb)
2 kg (4.4 lb)
Power supply Operation of transducer only with approved Siemens Milltronics controllers
Material Standard: Standard: Standard:
PVDF PVDF PVDF
Flanged: Flanged: Flanged:
PVDF with CPVC flange PVDF with CPVC flange PVDF with CPVC flange
Option: Option: Option:
PTFE face with CPVC flange PTFE face with CPVC flange PTFE face with CPVC flange
Color Blue Standard: Blue
Blue
XPS-15F:
Gray
Process connection 1" NPT or 1" BSPT Standard: 1.5" universal thread (NPT or BSPT)
1" NPT or 1" BSPT
XPS-15F:
1" NPT
Degree of protection IP66/68 IP66/68 IP66/68
Cable 2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket
Separation Max. 365 m (1 200 ft)
Certificates and approvals Standard: Standard: CE, CSA, FM, ATEX, IECEx
CE, CSA, FM, ATEX, IECEx CE, CSA, FM, ATEX, IECEx
XPS-15F:
FM Class I, Div. 1, Groups A, B, C and
D, Class II Div. 1, Groups E, F and G,
Class III
1)
EMC certificate available on request.

Siemens FI 01 · 2015 4/179


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax XPS-10 ultrasonic transducer 7ML1115- Further designs
High-frequency ultrasonic transducer designed 777 7 0 Please add "-Z" to Article No. and specify Order
for a wide variety of liquid and solid applications, code(s).
for use with approved controllers. Includes integral Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
temperature sensor. Measuring point number/ identification
Measuring range: min. 0.3 m, max.10 m (max. 27 characters) specify in plain text
Click on the Article No. for the online configura- Operating Instructions Article No.
tion in the PIA Life Cycle Portal.
Quick Start guide, multi-language A5E32282889
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0 Applications Guidelines, multi-language 7ML1998-5HV61
1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Note: The Applications Guidelines should be
with foam facing1) ordered as a separate line item on the order.
1" NPT [(Taper), ANSI/ASME B1.20.1] 2 This device is shipped with the Siemens Milltronics
with PTFE facing2) manual DVD containing the ATEX Quick Start and
Operating Instructions library.
R 1" [(BSPT), EN 10226] ¢ 3
R 1" [(BSPT), EN 10226] with foam facing1) 4 Accessories

4 R 1" [(BSPT), EN 10226] with PTFE facing2)


Cable length
5 Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
7ML1930-1BJ

sensors
5 m (16.40 ft) ¢ B
10 m (32.81 ft) ¢ C Submergence shield kit 7ML1830-1BH
30 m (98.43 ft) ¢ E Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
50 m (164.04 ft) F Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX
100 m (328.08 ft) K 1" and 1½" BSPT aluminum couplings
Mounting flange Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
None ¢ A Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
3" ASME, 150 lb, flat faced C 1½" BSPT 304 stainless steel couplings
4" ASME, 150 lb, flat faced D Universal box bracket, mounting kit 7ML1830-1BK
6" ASME, 150 lb, flat faced E Channel bracket, wall mount 7ML1830-1BL
8" ASME, 150 lb, flat faced F Extended channel bracket, wall mount 7ML1830-1BM
DN 80, PN 10/16, Type A, flat faced G Channel bracket, floor mount 7ML1830-1BN
DN 100, PN 10/16, Type A, flat faced J
DN 150, PN 10/16, Type A, flat faced L Extended channel bracket, floor mount 7ML1830-1BP

JIS10K3B Style M Bridge channel bracket, floor mount 7ML1830-1BQ


(see Mounting Brackets on page 4/187 for
JIS10K4B Style P more information)
JIS10K6B Style R
(Note: Flange bolting patterns and facings 1" NPT locknut, plastic 7ML1830-1DS
dimensionally correspond to the applicable 1" BSPT locknut, plastic 7ML1830-1DR
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
Approvals
ATEX 2GD Ex mb IIC T4 Gb, Ex tb IIIC T135 °C Db;¢ 3
IECEx SIR 13.0009X Ex mb IIC T4 Gb, Ex tb IIIC
T135 °C Db; FM Class I, Div. 2, Groups A,B,C,D;
Class II, Div. 1, Groups E,F,G; Class III
CSA Class I, Div. 1, Groups A,B,C,D, Class II, ¢ 4
Div. 1, Groups E,F,G, Class III 3)
1) Not available with flanged versions
2) Available with flanged versions only
3) Valid with mounting thread and facing options 0 ... 2 only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/180 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax XPS-15 ultrasonic transducer 7ML1118- Further designs
High-frequency ultrasonic transducer designed 7777 0 Please add "-Z" to Article No. and specify Order
for a wide variety of liquid and solid applications, code(s).
for use with approved controllers. Includes integral
temperature sensor. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring range: min. 0.3 m, max. 15 m Measuring point number/ identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal. Operating Instructions Article No.
Mounting thread and facing Quick Start guide, multi-language A5E32282889
1" NPT [(Taper), ANSI/ASME B1.20.1] ¢ 0
Applications Guidelines, multi-language 7ML1998-5HV61
1" NPT [(Taper), ANSI/ASME B1.20.1] 1
Note: The Applications Guidelines should be
with foam facing1) ordered as a separate line item on the order.
1" NPT [(Taper), ANSI/ASME B1.20.1] 2
with PTFE facing2) This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
R 1" [(BSPT), EN 10226] ¢ 3 Operating Instructions library.
R 1" [(BSPT), EN 10226] with foam facing1) 4
R 1" [(BSPT), EN 10226] with PTFE facing2) 5 Accessories
Cable length
5 m (16.40 ft) ¢ B
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77 inch), one text line for fastening on
7ML1930-1BJ
4
10 m (32.81 ft) ¢ C sensors
30 m (98.43 ft) ¢ E Submergence shield kit 7ML1830-1BJ
50 m (164.04 ft) F
Universal box bracket, mounting kit 7ML1830-1BK
100 m (328.08 ft) K
Mounting flange Channel bracket, wall mount 7ML1830-1BL
None ¢ A Extended channel bracket, wall mount 7ML1830-1BM
6" ASME, 150 lb, flat faced D Channel bracket, floor mount 7ML1830-1BN
8" ASME, 150 lb, flat faced E
Extended channel bracket, floor mount 7ML1830-1BP
DN 150, PN 10/16, Type A, flat faced J
DN 200, PN 10, Type A, flat faced K Bridge channel bracket, floor mount 7ML1830-1BQ
(see Mounting Brackets on page 4/187 for
JIS10K 6B N more information)
JIS10K 8B P
(Note: Flange bolting patterns and facings 1" NPT locknut, plastic 7ML1830-1DS
dimensionally correspond to the applicable
1" BSPT locknut, plastic 7ML1830-1DR
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
Approvals Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
ATEX 2GD Ex mb IIC T4 Gb, Ex tb IIIC T135 °C Db; ¢ 3 Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX
IECEx SIR 13.0009X Ex mb IIC T4 Gb, Ex tb IIIC 1" and 1½" BSPT aluminum couplings
T135 °C Db; FM Class I, Div. 2, Groups A,B,C,D;
Class II, Div. 1, Groups E,F,G; Class III Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
CSA Class I, Div. 1 Groups A,B,C,D, Class II, ¢ 4 Easy Aimer 304, with M20 adapter and 1" and 1½" 7ML1830-1GN
Div. 1, Groups E,F,G, Class III 3) BSPT 304 stainless steel couplings
1)
Not available with flanged versions ¢ We can offer shorter delivery times for configurations designated with the
2)
Available with flanged versions only Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
3)
Available with mounting options 0 ... 2 only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/181


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data Article No. Selection and Ordering data Article No.
EchoMax XPS-15F ultrasonic transducer 7ML1171- EchoMax XPS-30 ultrasonic transducer 7ML1123-
High-frequency ultrasonic transducer designed High-frequency ultrasonic transducer designed
777 7 0 7777 0
for a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications,
for use with approved controllers. Includes integral for use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Measuring range: min. 0.3 m, max. 15 m 1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Click on the Article No. for the online configura- Measuring range: min. 0.6 m (1.97 ft), max. 30 m
tion in the PIA Life Cycle Portal. (98.43 ft)
Mounting thread and facing Click on the Article No. for the online configura-
1" NPT [(Taper), ANSI/ASME B1.20.1] 1 tion in the PIA Life Cycle Portal.
Cable length Mounting thread and facing
5 m (16.40 ft) B 1½" universal thread 0
10 m (32.81 ft) C 1½" universal thread, foam facing1) 1
30 m (98.43 ft) D 1½" universal thread, PTFE facing2) 2
50 m (164.04 ft) E Cable length

4
100 m (328.08 ft) F 5 m (16.40 ft) B
Mounting flange, flush mount 10 m (32.81 ft) C
None A 30 m (98.43 ft) E
6" ASME, 150 lb, flat faced B 50 m (164.04 ft) F
8" ASME, 150 lb, flat faced C 100 m (328.08 ft) K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable Mounting flange
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.) None A
Approvals 6" ASME, 150 lb, flat faced D
FM Class I, Div. 1, Groups A, B, C, and D, Class II 1 8" ASME, 150 lb, flat faced E
Div. 1, Groups E, F, and G, Class III
DN 150, PN 10/16, Type A, flat faced J
DN 200, PN 10, Type A, flat faced K
Selection and Ordering data Order code
JIS10K 6B N
Further designs
JIS10K 8B P
Please add "-Z" to Article No. and specify Order
(Note: Flange bolting patterns and facings
code(s).
dimensionally correspond to the applicable
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
Measuring point number/ identification
Approvals
(max. 27 characters) specify in plain text
ATEX 2G 1D Ex mb IIC T4 Gb, Ex ta IIIC T135 °C 5
Operating Instructions Article No. Da; IECEx SIR 13.0009X Ex mb IIC T4 Gb,
English A5E32725813 Ex ta IIIC T135 °C Da
1) Not available with flanged versions
Applications Guidelines, multi-language 7ML1998-5HV61
Note: The Applications Guidelines should be 2) Available with flanged versions only
ordered as a separate line item on the order.
Selection and Ordering data Order code
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and Further designs
Operating Instructions library. Please add "-Z" to Article No. and specify Order
code(s).
Accessories
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ measuring-point number/identification
(0.47 x 1.77 inch), one text line for fastening on (max. 27 characters) specify in plain text
sensors
Operating Instructions Article No.
Submergence shield kit 7ML1830-1BJ
Quick Start guide, multi-language A5E32282889
Universal box bracket, mounting kit 7ML1830-1BK
Applications Guidelines, multi-language 7ML1998-5HV61
Channel bracket, wall mount 7ML1830-1BL Note: The Applications Guidelines should be
Extended channel bracket, wall mount 7ML1830-1BM ordered as a separate line item on the order.
Channel bracket, floor mount 7ML1830-1BN This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Extended channel bracket, floor mount 7ML1830-1BP Operating Instructions library.
Bridge channel bracket, floor mount 7ML1830-1BQ Accessories
(see Mounting Brackets on page 4/187 for
more information) Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77 inch), one text line for fastening on
1" NPT locknut, plastic 7ML1830-1DS sensors
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ 1½" BSPT locknut, plastic 7ML1830-1DP
Easy Aimer 304 with stainless steel coupling 7ML1830-1AU Easy Aimer 2, 1½" NPT galvanized coupling 7ML1830-1AN
Easy Aimer 304, NPT with 1½" coupling 7ML1830-1AT
Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX
1" and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 stainless steel couplings

4/182 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS
Selection and Ordering data Article No. Selection and Ordering data Order code
EchoMax XPS-30C ultrasonic transducer 7ML1155- Further designs
High-frequency ultrasonic transducer designed Please add "-Z" to Article No. and specify Order
777 7 1
for a wide variety of liquid and solid applications, code(s).
for use with approved controllers. Includes integral
temperature sensor. Stainless steel tag [69 mm x 50 mm Y15
1½" universal thread compatible with 1½" NPT and (2.71 x 1.97 inch)]: Measuring-point number /
R 1½" [(BSPT), EN 10226] identification (max. 27 characters) specify in plain
Measuring range: min. 0.6 m (1.97 ft), max. 30 m text
(98.43 ft) Operating Instructions Article No.
Click on the Article No. for the online configura- Quick Start guide, multi-language A5E32282889
tion in the PIA Life Cycle Portal.
Applications Guidelines, multi-language 7ML1998-5HV61
Mounting thread and facing Note: The Applications Guidelines should be
1½" universal thread 0 ordered as a separate line item on the order.
1½" universal thread, foam facing1) 1
This device is shipped with the Siemens Milltronics
1½" universal thread, PTFE facing2) 2 manual DVD containing the ATEX Quick Start and
Cable length Operating Instructions library.

4
5 m (16.40 ft) B Accessories
10 m (32.81 ft) C
Easy Aimer II NPT 1.5" Galvanized 7ML1830-1AN
30 m (98.43 ft) E
Easy Aimer 304, NPT with 1.5" coupling 7ML1830-1AT
50 m (164.04 ft) F
100 m (328.08 ft) K 1½" BSPT locknut, plastic 7ML1830-1DP
1)
Mounting flange Not available with flanged version
2)
None A Available for flanged versions only
6" ASME, 150 lb, flat faced D
8" ASME, 150 lb, flat faced E
DN 150, PN 10/16, Type A, flat faced J
DN 200, PN 10, Type A, flat faced K
JIS10K 6B N
JIS10K 8B P
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1, or JIS B 2220 standard.)
Approvals
CSA, Class I, Div. 2, Groups A,B,C,D; Class II, 4
Div. 1, Groups E,F, G; Class III

Siemens FI 01 · 2015 4/183


© Siemens AG 2014

Level Measurement
Continuous level measurement – Ultrasonic transducers
EchoMax XPS

■ Dimensional drawings ■ Schematics


Standard Submergence shield Direct connection
J

Black
White
B

Shield

F
Coaxial connection
A Radiating face

Bonded flange White


Shield

4
B

3 terminal direct*
C
Black

XPS ultrasonic transducer, dimensions in mm (inch) Shield

White
Version
Dimension XPS-10 XPS-15 XPS-30
A 88 mm 121 mm 175 mm
(3.464 inch) (4.764 inch) (6.890 inch)
3 terminal extension*
B 122 mm 132 mm 198 mm
Black
(4.803 inch) (5.197 inch) (7.795 inch)
C According to ASME, DIN and JIS White
E 124 mm 158 mm n/a Shield
(4.882 inch) (6.220 inch)
F 152 mm 198 mm n/a
(5.984 inch) (7.795 inch) * For SITRANS LUT400, MultiRanger 100/200, HydroRanger 200
J 28 mm 28 mm 28 mm
(1.1 inch) (1.1 inch) (1.1 inch)
Mounting
Make particularly sure that the radiating face of the transducer is
protected from damage. Mount the transducer so that it is above the
maximum material level by at least the blanking value. On liquid
applications, the transducer must be mounted so that the axis of
transmission is perpendicular to the liquid surface. On solids applications,
a Milltronics Easy Aimer should be used to facilitate aiming the
transducer. Consider the optional temperature sensor when mounting
the transducer.

Interconnection
Do not route cable openly or near high voltage or current runs, contactors
and SCR control drives. For optimum isolation against electrical noise,
run cable separately in a grounded metal conduit. Seal all thread
connections to prevent ingress of moisture.

XPS ultrasonic transducer connections

4/184 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
EA aiming devices

■ Application ■ Application
EA 304 aiming device EA 2 aiming device
The Easy Aimer 304 flange is a stainless steel aiming device for The Easy Aimer 2 flange is a cast aluminum aiming device for
alignment of Siemens ultrasonic transducers used for level mea- alignment of Siemens ultrasonic transducers.
surement of bulk solids.
The flange has graduated adjustments and an adjustable inser-
The sensor must be mounted aimed towards the low level draw tion length. When used for applications with bulk solids, the sen-
point in the silo. The sensor can be rotated through 360° and sor is mounted so that it is aimed towards the lower level draw
angled at 0 to 27° off vertical. It must be mounted using an point in the silo. The sensor can be rotated through 360° and
access plate with welded studs or a flange in order to isolate angled at 0 to 20° off vertical. It must be mounted using an
the mounting holes from the pressurized environment. When access plate with welded studs or a flange in order to isolate
installed properly, the EA 304 aiming device is capable of with- the mounting holes from the pressurized environment. When
standing pressures up to 0.5 bar (Europe) or 15 psi (North Amer- installed properly, the EA 2 aiming device is capable of with-
ica). It can even be used in corrosive and aggressive environ- standing pressures up to 0.5 bar (Europe) or 15 psi (North Amer-
ments. ica). It can even be used in corrosive and aggressive environ-
ments.

■ Dimensional drawings ■ Dimensional drawings


4
¾” NPT or BSP
conduit x 300 (12) long
Locknut
1" NPT or BSP
170 (6.7)

Conduit gland
Angle block
10 (0.38)

Clamping plate
(upper socket)

Mounting block Sighting block


(lower socket) 76 (3) 16 Mounting
nominal (0.63)
Customer gasket block
(as required) Customer
gasket
Ø127 (5) Customer
135 (5.3)

(as required)
nominal

typical mounting plate


(as required) Customer
127 (5) mounting plate
Coupling/adapter Ø typical
Coupling/ (as required)
Adapter
Siemens
Milltronics Siemens Milltronics
transducer Transducer (typical)
(typical)
max 20°

máx. 27° Mounting hole - 3 places


Mounting hole - to suit M8 or ⅜ inch,
3 places 11 (7/16) 120° apart on 157 mm
on 157 (6.2) bolt (6.2 inch) bolt center diameter
center diameter
Angle block binding
screw and clamp
CS
ONI
TR
LL
Sighting block binding
MI

Ground screw screw and clamp

Clamping screw
(3 places)
E

SY
A

A IM
ER
II

Ground screw
178 (7)
178
EA 304 aiming device, dimensions in mm (inch) (7.0)

EA 2 aiming device, dimensions in mm (inch)

Siemens FI 01 · 2015 4/185


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
EA aiming devices
Selection and Ordering data Article No.
Easy aimer
Used on solids applications to aim transducers for
optimal performance. Available in a 304 stainless
steel model, or a cast aluminum model.
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 stainless steel couplings
Easy Aimer 2, aluminum, BSPT conduit 7ML1830-1AL
Easy Aimer 2, aluminum, NPT with 1½" galvanized 7ML1830-1AN
coupling1)
Easy Aimer 2, aluminum, NPT with 1" galvanized 7ML1830-1AP
coupling
Easy Aimer 2, aluminum, NPT with ¾" x 1" 7ML1830-1AQ
PVC coupling
Easy Aimer 304, BSPT conduit 7ML1830-1AS
4 Easy Aimer 304, NPT with 1½" coupling1) 7ML1830-1AT
Easy Aimer 304, NPT with 1" coupling 7ML1830-1AU
Operating Instructions
Easy Aimer 2 and 304 Operating Instructions, 7ML1998-5HG62
Multi-language
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the Quick Start and Operat-
ing Instructions library.
1) For use with XPS-30 transducers only

4/186 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
FMS mounting brackets

■ Application ■ Integration
Siemens mounting brackets permit simple, fast installation of
ultrasonic transducers. These rugged, high quality mounting FMS-200
brackets are constructed of 304 (1.4301) stainless steel and are Universal box bracket
suitable for use indoors and outdoors. They adjust to fit almost
any application, saving you the time and expense of building
custom brackets. Each kit includes all mounting parts.
FMS-200
universal box bracket system
Mounting of units with 1 inch or 2 inch threaded connection.
Distance from sensor to wall or beam: 20 ... 31 cm (8 ... 12 inch).
FMS-210
The unique box design also acts as a sun shield for transducers Channel bracket,
with 1 inch threaded connections. wall mount
FMS-210
wall mounting set
Mounting of transducers with 1 inch threaded connection.
4
Distance from transducer to wall or beam: 12 ... 48 cm
(5 ... 19 inch). FMS-220
Extended channel bracket,
FMS-220 wall mount
extended wall mounting set
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to wall or beam: 32 ... 98 cm
(13 ... 39 inch).
FMS-310
floor mounting set
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch).
Distance from mounting support: 5 ... 57 cm (2 ... 22 inch).
FMS-310
FMS-320 Channel bracket,
extended floor mounting set floor mount
Mounting of transducers with 1 inch threaded connection.
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch).
Distance from mounting support: 41 ... 108 cm (16 ... 43 inch).
FMS-350
floor mounting set, bridge
Mounting of transducers with 1 inch threaded connection.
FMS-320
Distance from transducer to floor: 20 ... 48 cm (8 ... 19 inch), Extended channel bracket,
anywhere along the complete width of the bridge floor mount
[166 cm (65 inch)].
This kit is particularly suitable for measurements on open chan-
nels (OCM) by providing a very stable mount for the transducer
above a flume or weir.

FMS-350
Bridge channel bracket,
floor mount

FMS mounting brackets

Siemens FI 01 · 2015 4/187


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
FMS mounting brackets
Selection and Ordering data Article No.
Mounting brackets for XPS-10 sensors
FMS-200 universal box bracket set 7ML1830-1BK
FMS-210 wall mounting set 7ML1830-1BL
FMS-220 extended wall mounting set 7ML1830-1BM
FMS-310 floor mounting set 7ML1830-1BN
FMS-320 extended floor mounting set 7ML1830-1BP
FMS-350 floor mounting set, bridge 7ML1830-1BQ
Additional Operating Instructions
FMS-200 7ML1998-5BK61
FMS-210 7ML1998-5BL61
FMS-220 7ML1998-5BM61
FMS-310 7ML1998-5BN61

4 FMS-320
FMS-350
7ML1998-5BP61
7ML1998-5BQ61
Note: The Operating Instructions should be
ordered as a separate line item on the order.

4/188 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
TS-3 temperature sensor

■ Overview ■ Design
Clearance

Conduit (supplied by others)

Coupling (supplied by others)

TS-3

Plate or wall

4
Locknut (supplied by others)
The TS-3 temperature sensor provides an input signal for
temperature compensation of specific Siemens ultrasonic level Note: Clearance hole/
controllers. locknut Installation
method is not suitable
■ Benefits for pressure applications.

• Chemically resistant ETFE enclosure


• Fast response time Tapped
• Approved for use in potentially explosive atmospheres

■ Application
Temperature compensation is essential in applications where
temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of
the associated ultrasonic transducer, a signal representative of
the sound medium’s ambient temperature is obtained. The tem-
perature sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that
do not have an integral temperature sensor. It is also recom- Flange or wall
mended in cases where the integral temperature sensor of the
transducer cannot be used.
The following conditions are typical for use of the TS-3 sensor:
where a fast reaction to temperature variations is required, where
a flanged ultrasonic transducer is used, or where high tempera-
tures are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1
temperature sensors. Refer to the associated controller manual
for more details.
• Key Applications: For use in applications where temperature
sensor measurement from transducer does not accurately
represent vessel temperature. Used for applications requiring TS-3 temperature sensor
quick temperature response (open channel monitoring).

Siemens FI 01 · 2015 4/189


© Siemens AG 2014

Level Measurement
Continuous level measurement – Accessories for ultrasonic
TS-3 temperature sensor

■ Technical specifications Selection and Ordering data Article No.


TS-3 temperature sensor 7ML1813-
Mode of operation
TS-3 provides an input signal for temperature 77B 7
Measuring principle Temperature sensor compensation of specific Siemens ultrasonic level
Input controllers.
Measuring range -40 ... +100 °C (-40 ... +212 °F) Compensation is essential in applications where
variation in temperature of the sound medium is
Output expected.
Response time Click on the Article No. for the online configura-
• Forced circulation 55 s tion in the PIA Life Cycle Portal.
(temperature variation: 63 %)
• Flange, forced circulation 90 s Cable length
• Natural convection 150 s 1 m (3.28 ft) 1
Rated operating conditions 5 m (16.40 ft) 2
• Installation instructions Mounted indoors/outdoors, but not
exposed to direct sunlight 10 m (32.81 ft) 3
• Pressure Max. 4 bar (60 psi/400 kPa) 30 m (98.43 ft) 4

4 Design
Material (enclosure) ETFE1)
50 m (164.04 ft)
70 m (229.66 ft)
5
6
Cable connection 2-core, 0.5 mm² (20 AWG), shielded, 90 m (295.28 ft) 7
silicone sheath
Process connection
Process connection ¾" NPT [(Taper), ANSI/ASME
B1.20.1] ¾" NPT [(Taper), ANSI/ASME B1.20.1] A
R ¾" [(BSPT), EN 10226] B
R ¾" [(BSPT), EN 10226], totally
encapsulated Approvals
Certificates and approvals CE, IEC Ex, FM, CSA, ATEX CSA, FM 3
1)
CE, ATEX, IEC Ex 4
ETFE is a fluoropolymer inert to most chemicals. For exposure to specific
environments, check the chemical compatibility charts before installing the Operating Instructions
TS-3 in your application.
English A5E32337739

■ Dimensional drawings German A5E34990011


Note: The Operating Instructions should be
ordered as a separate line item on the order.
SITRANS LUT400
only This device is shipped with the Siemens Milltronics
S manual DVD containing ATEX Quick Starts and
BWH
L H L
KT D Operating Instructions.

Refer to associated Accessories


manual for terminal ¾" NPT locknut, aluminum 7ML1930-1BE
block detail
OR Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
BW
L H (0.47 x 1.77 inch) for fastening on sensors
KT

Connect direct or
Cable via customer junction box
136
(5.4)
15 20 15
76
(0.6) (0.8) (0.6)
(3.0)

¾" NPT or
BSP Hex hub
(2 places) 27 (1 1/16)

TS-3 temperature sensor, dimensions in mm (inch)

4/190 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters

■ Overview ■ Mode of operation


Radar measurement technology is non-contacting and low Principle of Operation
maintenance. Because microwaves require no carrier medium,
they are virtually unaffected by the process atmosphere (vapor, Radar measurement technology measures the time of flight from
pressure, dust, or temperature extremes). Siemens offers a vari- the transmitted signal to the return signal. From this time,
ety of models to meet the specific needs of your application. distance measurement and level are determined.

SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmit- Unlike ultrasonic measurement, radar technology does not
ter for continuous monitoring of liquids and slurries in storage require a carrier medium and travels at the speed of light
vessels with nominal pressure and temperature, to a range of (300 000 000 m/s). Most industrial radar devices operate from
20 m (66 ft). 6 to 26 GHz.

SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter Siemens offers pulse radar transmitters (SITRANS Probe LR,
for continuous monitoring of liquids and slurries in process ves- SITRANS LR200, SITRANS LR250, SITRANS LR260) and FMCW
sels including high temperature, pressure, agitation, (Frequency Modulated Continuous Wave) radar transmitters
and turbulence to a range of 20 m (65 ft). (SITRANS LR460, SITRANS LR560).

SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter Pulse radar emits a microwave pulse from the antenna at a fixed
repetition rate that reflects off the interface between the two
4
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, materials with different dielectric constants (the atmosphere and
corrosive or aggressive materials, to a range of 20 m (66 ft). the material being monitored). The echo is detected by a
Ideal for small vessels and low dielectric media. receiver and the transmit time is used to calculate level.

SITRANS LR260 is a 2-wire, 25 GHz pulse radar level transmitter Reflected echoes are digitally converted to an echo profile.
for continuous monitoring of solids in silos to a range of 30 m The profile is analyzed to determine the distance from the mate-
(98.4 ft). Ideal for applications with extreme dust and high tem- rial surface to the reference point on the instrument.
peratures to 200 °C (392 °F) and liquids in vessels. FMCW (Frequency Modulated Continuous Wave) radar devices
SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmit- send microwaves to the surface of the material. The wave
ter with extremely high signal to noise ratio and advanced signal frequency is modulated continuously. At the same time,
processing for continuous monitoring of solids up to 100 m the receiver is also receiving continuously and the difference in
(328 ft). It is ideal for measurement in extreme dust. frequency between the transmitter and the receiver is directly
proportional to the distance to the material.
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).
Auto False-Echo Suppression
SITRANS LR instruments offer the unique advantage of patented Level (db)
Process Intelligence signal processing technology.
This in-depth knowledge and experience is built into the soft-
ware’s advanced algorithms to provide intelligent processing of
echo profiles. The result is repeatable, fast and reliable mea-
surement. Echo from
agitator
A special feature of SITRANS radar devices is Auto False-Echo
Suppression, an echo processing technique that automatically
detects and suppresses false echoes from vessel obstructions.
You can implement this feature using two parameters on the Surface echo
local interface or SIMATIC PDM communicating over HART or
PROFIBUS PA.

Local display interface – graphically displays echo


profiles and diagnostic information
(available with LR200, LR250, LR260 and LR560)
Quick to configure – Quick Start Wizard via SIMATIC
PDM guides you during setup
(available with LR200, LR250, LR260, LR460, LR560)
Distance

Radar operation in a reactor vessel

Siemens FI 01 · 2015 4/191


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters

■ Technical specifications
Radar Selection Guide
Criteria SITRANS SITRANS SITRANS SITRANS SITRANS SITRANS
Probe LR LR200 LR250 LR260 LR460 LR560
Typical industries Chemicals, petro- Chemicals, petro- Chemicals, petro- Cement, power Cement, power Cement, power
chemicals, water/ chemicals, aluminum, chemicals, and oil generation, petro- generation, food generation, food
waste-water, drilling wastewater and gas, mining, chemical, food processing, mineral processing, mineral
mud marine, food and processing, mineral processing, mining processing, mining
beverage, and phar- processing, mining
maceutical
Typical applications Liquids, storage Liquids, process Liquids, storage and Cement, plastics, Cement, fly ash, Cement, fly ash,
vessels, wet wells, vessels with agita- process vessels with grain, flour, coal, grain, coal, flour, grain, coal, flour,
and drilling mud tors, build-up, and agitators, vaporous liquids < 20 m, and plastics plastics
tanks high temperatures liquids, high temper- low dielectric liquids
atures, low dielectric < 30 m
media, and crude oil
produced water

4
Range 0.3 ... 20 m 0.4 ... 20 m 50 mm (2 inch) 30 m (98.4 ft) 100 m (328 ft) 40 m (131 ft)
(1 ... 65 ft) (1.3 ... 65 ft) from end of horn 100 m (328 ft)
to 20 m (65 ft),
horn dependent
Frequency 5.8 GHz 5.8 GHz K-band K-band 24 ... 25 GHz FMCW 78 ... 79 GHz
(North America (North America (25.0 GHz) (25.0 GHz)
6.3 GHz) 6.3 GHz)
Performance 0.1 % of range or 0.1 % of range or  5 mm (0.02 inch) 25 mm (1 inch) from 0.25 % 0.25 %
accuracy 10 mm (0.4 inch) 10 mm (0.4 inch) minimum detectable
distance to 300 mm
(11.8 inch)
Remainder of range
= 10 mm (0.39 inch)
or 0.1 % of span
(whichever is greater)
Temperature Ambient: Ambient: Ambient: Ambient: Ambient: Ambient:
-40 ... +80 °C -40 ... +80 °C -40 ... +80 °C -40 ... +80 °C +65 °C (+149 °F) -40 ... +80 °C
(-40 ... +176 °F) (-40 ... +176 °F) (-40 ... +176 °F) (-40 ... +176 °F) (-40 ... +176 °F)
Process: Process: Process: Process: Process: Process:
-40 ... +80 °C -40 ... +200 °C -40 ... +200 °C -40 ... +200 °C +200 °C -40 ... +100 °C
(-40 ... +176 °F (-40 ... +392 °F), (-40 ... +392 °F) (-40 ... +392 °F) (+392 °F) (-40 ... 212 °F)
dependent on dependent on dependent on Optional:
antenna type antenna type antenna type +200 °C (+392 °F)
Output/communica- • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART
tions/remote configu- • SIMATIC PDM • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA
ration and • SIMATIC PDM • FOUNDATION • SIMATIC PDM • SIMATIC PDM • FOUNDATION
diagnostics • AMS Fieldbus Fieldbus
• SITRANS • SIMATIC PDM • SIMATIC PDM
DTM/FDT for • AMS • AMS
PACTware, • SITRANS • SITRANS
Fieldcare, DTM/FDT for DTM/FDT for
etc. PACTware, PACTware,
Fieldcare, Fieldcare,
etc. etc.
Power • 24 V DC nominal • 24 V DC nominal • 24 V DC nominal • 24 V DC nominal • 100 ... 230 V AC, • 24 V DC nominal
• Loop powered • Loop powered • Loop powered • Loop powered ±15 %, 50/60 Hz, • Loop powered
6W
• 24 V DC,
+25/-20 %, 6 W
Approvals CE, RCM, Lloyds CE, RCM, Lloyds CE, RCM, Lloyds CE, RCM, FCC, CE, RCM, FCC, CE, RCM, FCC,
Register of Shipping, Register of Shipping, Register of Shipping, Industry Canada, Industry Canada, Industry
ABS, ABS, FCC, Industry ABS, BV, FCC, Indus- R&TTE R&TTE Canada, R&TTE
FCC, Industry Canada, R&TTE try Canada, R&TTE ATEX, CSA, FM, ATEX, CSA, FM, ATEX, CSA, FM,
Canada, R&TTE ATEX, CSA, FM, ATEX, CSA, FM, INMETRO, GOST, INMETRO, IECEx, INMETRO, IECEx,
ATEX, CSA, FM, INMETRO, GOST-R, INMETRO, GOST-R, IECEx GOST NEPSI, GOST
INMETRO, GOST-R, IECEx, ANZEx, TIIS, IECEx, TIIS, NEPSI
IECEx, ANZEx, TIIS NEPSI Functional safety
SIL-2, EHEDG, 3-A,
USP Class VI

4/192 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
Radar transmitters

■ Application

Radar Application Questionnaire

Customer information

Contact: Prepared By:


Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: (
(
)
)
4
E-mail: Fax:

Vessel Information Sketch attached


LR 400
SITRANS

Storage Storage Process Reactor


Solids Liquids

Area safety classification: (specify code required)


Height: m/ft Diameter: m/ft Filling method:
Top: Atmosphere: (indicate all that apply) Pressure:
Flat Foam Steam Normal:
Parabolic Dust Deposit (build-up) Maximum (relief):
Conical Vapor
Mounting connection (specify type) Critical Information
Distance to sidewall: cm/inch
Nozzle Length: cm/inch
Mounting connection maximum temperature: C/ F
Nozzle Diameter: cm/inch
Max. temperature at electronics: C/ F

Stilling well or Still Pipe mounting: Yes No Stilling well diameter: cm/inch

Material

Material being measured: Liquid Solid Liquified gas

Material temperature: Norm: C/ F Max: C/ F


Material surface: Flat Tu Agitated Vortex Dielectric constant: r< r>

Installation Communications:

Power available: HART /4 ... 20 mA


PROFIBUS PA
FOUNDATION Fieldbus None

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-763R7

Siemens FI 01 · 2015 4/193


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR

■ Overview ■ Configuration
Installation
Min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.

Beam
angle 28°

4
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmit-
ter for continuous monitoring of liquids and slurries in storage Mounting unit on vessel
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).

■ Benefits
• Uni-Construction polypropylene rod antenna standard
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART handheld communicator
• Communication using HART Conical Flat Parabolic
• Process Intelligence signal processing
• Extremely high signal-to-noise ratio Mounting on a manhole cover Mounting on a nozzle
• Auto False-Echo Suppression of false echoes

■ Application
The Probe LR is ideal for applications with chemical vapors,
temperature gradients, vacuum or pressure, such as simple

Min.
10 (0.4)
chemical storage or water treatment vessels. SITRANS Probe LR
has a range of 0.3 to 20 m (1 to 65 ft).
Probe LR is designed for safe and simple programming using Min. 100 (4)
the Intrinsically Safe handheld programmer without having to SITRANS Probe LR
open the instrument’s lid. It has a standard Uni-Construction shield length 100 (4) or
polypropylene rod antenna that offers excellent chemical resis- 250 (10) standard
tance and is hermetically sealed. The Uni-Construction antenna lengths
includes an internal, integrated shield that eliminates vessel noz-
zle interference. SITRANS Probe LR installation, dimensions in mm (inch)
SITRANS Probe LR incorporates Process Intelligence signal
processing. The Probe LR also has a high signal-to-noise ratio
leading to improved reliability.
Start-up is easy with as few as two parameters for basic opera-
tion. Programming is simple using SIMATIC PDM, HART hand-
held communicator or the Intrinsically Safe handheld program-
mer.
• Key Applications: chemical storage, wastewater wet well,
and drilling mud

4/194 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR

■ Technical specifications
Mode of operation Power supply • Nominal 24 V DC with max. 550 ,
maximum 30 V DC
Measuring principle Pulse radar level measurement • 4 ... 20 mA
Frequency 5.8 GHz (North America 6.3 GHz) Certificates and approvals
Measuring range 0.3 ... 20 m (1.0 ... 65 ft) General CSAUS/C, CE, FM, RCM
Output Marine • Lloyd's Register of Shipping
Analog output 4 ... 20 mA • ABS Type Approval
Accuracy ± 0.02 mA Radio FCC, Industry Canada and European
(R&TTE), RCM
Span Proportional or inversely proportional
Hazardous
Communications HART • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga
Performance (reference conditions) • Intrinsically Safe (Canada) CSA Class I, Div.1, Groups A,B,C,D;
Class II, Div. 1, Group G; Class III
Accuracy ± the greater of 0.1 % of range or
10 mm (0.4 inch) • Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T4
• Intrinsically Safe (International) IECEx Ex ia IIC T4

4
Influence of ambient temperature 0.003 %/K • Intrinsically Safe (Russia) GOST-R Ex ia
Repeatability ± 5 mm (2 inch) • Intrinsically Safe (USA) FM Class I, Div.1, Groups A,B,C,D;
Class II, Div. 1, Groups E,F, G;
Fail-safe mA signal programmable as high, Class III
low or hold (LOE)
Programming
Rated operating conditions
Handheld programmer HART communicator 375
Installation conditions
PC SIMATIC PDM
• Location Indoor/outdoor
Intrinsically safe Siemens handheld Infrared receiver
Ambient conditions (enclosure) programmer (optional)
• Ambient temperature -40 ... +80 °C (-40 ... +176 °F) • Approvals (handheld programmer) ATEX II 1G EEx ia IIC T4
CSA and FM Class I, Div.1,
• Installation category I Groups A,B,C,D, T6 at max. ambient
• Pollution degree 4 Display (local) Multi-segment alphanumeric liquid
Medium conditions crystal with bar graph (representing
level) available in four languages
Dielectric constant r r > 1.6 (for r < 3, use stillpipe)
Vessel temperature -40 ... +80 °C (-40 ... +176 °F)
Vessel pressure 3 bar g (43.5 psi g)
Design
Enclosure
• Body construction PBT (Polybutylene Terephthalate)
• Lid construction PEI (Polyether Imide)
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT with
adapter
Degree of protection Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
Weight 1.97 kg (4.35 lb)
Antenna
• Material Polypropylene rod, hermetically
sealed construction
• Dimensions Standard 100 mm (4 inch) shield for
maximum 100 mm (4 inch) nozzle or
optional 250 mm (10 inch) long shield
Process connections 1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]

Siemens FI 01 · 2015 4/195


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS Probe LR 7ML5430- Further designs
2-wire, 6 GHz pulse radar level transmitter for Please add "-Z" to Article No. and specify Order
continuous monitoring of liquids and slurries in 7777 0 code(s).
storage vessels with nominal pressure and
temperature, to a range of 20 m (66 ft). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Max. 3 bar g (43.5 psi g) pressure and (max. 27 characters) specify in plain text
80 °C (176 °F)
Click on the Article No. for the online configura- Manufacturer's test certificate: M to DIN 55350, ¢ C11
tion in the PIA Life Cycle Portal. Part 18 and to ISO 9000
Enclosure/Cable inlet Operating Instructions Article No.
Plastic, (PBT), 2 x ½" NPT ¢ 1 English A5E32337711
Plastic, (PBT), 2 x M20x1.5 ¢ 2
Antenna type/Material - (max. 3 bar and 80 °C) French 7ML1998-5HR11
Polyproylene Antenna Spanish 7ML1998-5HR21
1½" NPT [(Taper), ANSI/ASME B1.20.1], ¢ A German A5E34957879
comes with integral 100 mm shield Note: The Operating Instructions should be
R 1½" [(BSPT), EN 10226], ¢ B
4
ordered as a separate item on the order.
comes with integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1], ¢ C This device is shipped with the Siemens Milltronics
comes with integral 100 mm shield manual DVD containing the ATEX Quick Start and
1½" NPT [(Taper), ANSI/ASME B1.20.1], ¢ D Operating Instructions library.
comes with integral 250 mm shield Additional Operating Instructions
R 1½" [(BSPT), EN 10226], ¢ E
comes with integral 250 mm shield Multi-language Quick Start manual A5E32106153
G 1½" [(BSPP), EN ISO 228-1], ¢ F Accessories
comes with integral 250 mm shield
Approvals Handheld programmer, Intrinsically Safe, 7ML5830-2AH
General Purpose, CE, R&TTE, RCM ¢ A ATEX II 1G, Ex ia
General Purpose, CSAus/c, FM, FCC ¢ B HART modem/USB 7MF4997-1DB
CSA Class I, Div. 1, Groups A, B, C, D, Class II, ¢ C (for use with a PC and SIMATIC PDM)
Div. 1 Group G, Class III, FCC, Intrinsically Safe
One metallic cable gland M20x1.5, 7ML1930-1AP
FM, Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, ¢ D rated -40 ... +80 °C (-40 ... +176 °F)
FCC, Intrinsically Safe
IECEx Ex ia IIC T4; ATEX II 1G EEx ia IIC T4, ¢ E SITRANS RD100, loop powered display - 7ML5741-...
R&TTE, RCM, Intrinsically Safe; see Chapter 7
INMETRO Ex ia IIC T4 Ga; GOST-R
SITRANS RD200, universal input display with 7ML5740-...
Communication/Output Modbus conversion - see Chapter 7
4 ... 20 mA, HART ¢ 1
SITRANS RD300, dual line display with totalizer 7ML5744-...
¢ We can offer shorter delivery times for configurations designated with the and linearization curve and Modbus conversion -
Quick Ship Symbol ¢. For details see page 9/5 in the appendix. see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
Spare parts
Plastic lid 7ML1830-1KB
For applicable back up point level switch -
see point level measurement section
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/196 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS Probe LR

■ Dimensional drawings
½" NPT cable entry
(or alternatively M20 x 1.5)

Lid
Lid screws

129 139
(5.1) (5.5)

Enclosure /
Option: 423 (16.7) max.

electronics
Std.: 273 (10.8) min.

(5.3)
134

103.5
Locking collar

(4)
mounting thread

4
1½" NPT,
R 1½" BSPT,
G 1½" BSPP 23 (0.9)
Option: 702 (27.6) max.

Inactive shield length


Std.: 552 (21.7) min.

(internal)
Standard: 100 (4)
Optional: 250 (10)

Std. 115 (4.5)


[Optional 268 (10.5)]
Polypropylene
rod antenna

SITRANS Probe LR, dimensions in mm (inch)

■ Schematics
Hand Programmer
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.

Strain relief SITRANS Probe LR


(or NPT cable inlet) Part number: 7ML5830-2AH

Notes:
- DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
- All field wiring must have insulation suitable for rated input voltages.
- Use shielded twisted pair cable (14-22 AWG)
- Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS Probe LR connections

Siemens FI 01 · 2015 4/197


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200

■ Overview ■ Configuration
Installation Min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.

Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• Beam angle for horn antenna
dependent on horn size
• The peak energy density is
directly in front of and in line
Beam
with the rod antenna.
angle 28°
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be

4 detected.

SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter


Mounting unit on vessel
for continuous monitoring of liquids and slurries in process ves-
sels including high temperature, pressure, agitation,
and turbulence to a range of 20 m (65 ft).

■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved Conical Flat Parabolic
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
Mounting unit on stilling well Mounting on a nozzle
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM Orient front or
back of device
■ Application toward stillpipe
slots.
SITRANS LR200’s unique design allows safe and simple
programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. It also features a
built-in alphanumeric display in four languages.

Min. 10 (0.4)
The SITRANS LR200 has a standard Uni-Construction polypro-
pylene rod antenna that offers excellent chemical resistance and
is hermetically sealed. The Uni-Construction antenna features
an internal, integrated shield that eliminates vessel nozzle inter-
ference.
Start-up is easy with as few as two parameters for basic opera-
tion. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up SITRANS LR200 installation, dimensions in mm (inch)
with conduit or wiring connections or simply to adjust the posi-
tion for easy viewing. SITRANS LR200 features patented Pro-
cess Intelligence signal-processing technology for superior
reliability.
• Key Applications: liquid process vessels with agitators,
vaporous liquids, high temperatures, asphalt, digesters

4/198 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200

■ Technical specifications
Mode of operation Power supply
Measuring principle Radar level measurement 4 ... 20 mA/HART
Frequency 5.8 GHz (North America 6.3 GHz) • General Purpose, Non-incendive, Nominal 24 V DC (max. 30 V DC)
Intrinsically Safe with max. 550 
Measuring range 0.3 ... 20 m (1.0 ... 65 ft) • Flame proof, Increased safety, Nominal 24 V DC (max. 30 V DC)
Output Explosion proof with max. 250 
• Analog output 4 ... 20 mA PROFIBUS PA • 10.5 mA
• Accuracy ± 0.02 mA • Per IEC 61158-2
• Span Proportional or inversely proportional Certificates and approvals
• Communications HART
General CSAUS/C, CE, FM, RCM
Optional: PROFIBUS PA
(Profile 3.0, Class B) Marine • Lloyd’s Register of Shipping
• Fail-safe Programmable as high, • ABS Type Approval
low or hold (Loss of Echo) Radio FCC, Industry Canada and European
Performance (according to (R&TTE), RCM
reference conditions IEC60770-1)
4
Hazardous
• From end of antenna to 600 mm: 40 mm (1.57 inch) • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga
• Remainder of range: 10 mm (0.4 inch) or 0.1 % of span • Explosion Proof (Canada/USA) CSA/FM, Class I, Div. 1,
(whichever is greater) Groups A, B, C, D; Class II, Div. 1,
Rated operating conditions Groups E, F, G; Class III, T4
• Intrinsically Safe (Canada/USA) CSA/FM, Class I, Div. 1,
Installation conditions Groups A, B, C, D; Class II, Div. 1,
• Location Indoor/outdoor Groups E, F, G; Class III, T4
Ambient conditions (enclosure) • Non-incendive (USA) FM, Class I, Div. 2, Groups A, B, C, D,
T5
• Ambient temperature -40 ... +80 °C (-40 ... +176 °F)
• Flame Proof/Increased Safety NEPSI Ex d mb ia IIC T4/
• Installation category I (China) Ex e mb ia IIC T4
• Pollution degree 4 • Flame Proof (Europe) ATEX II 1/2 G Ex d mb ia IIC T4
Medium conditions Ga/Gb
• Dielectric constant r r > 1.6 (for r < 3, use stillpipe) • Increased Safety (Europe) ATEX II 1/2 G Ex e mb ia IIC T4
Ga/Gb
• Vessel temperature and pressure Varies with connection type;
see Pressure/Temperature curves for • Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4
more information • Intrinsically Safe (International) IECEx Ex ia IIC T4
• Intrinsically Safe (Russia) GOST-R Ex ia
Design
Programming
Enclosure
• Intrinsically Safe Siemens handheld Infrared receiver
• Material Aluminum, polyester powder coated programmer
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT with - Approvals for handheld IS model:
adapter programmer ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135 °C Ta = -20 ... +50 °C
Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA 6,
CSA/FM Class I, II, and III, Div. 1,
IP67, IP68
Groups A, B, C, D, E, F, G, T6
Weight < 2.82 kg (6.21 lb) Ta = +50 °C
(polypropylene rod antenna) • Handheld communicator HART communicator 375
Display (local) Multi-segment alphanumeric liquid • PC • SIMATIC PDM
crystal with bar graph (representing • AMS
level) available in four languages • Display (local) Multi-segment alphanumeric liquid
crystal with bar graph (representing
Antenna level) available in four languages
• Material Polypropylene rod, hermetically
sealed construction, optional PTFE
• Dimensions Standard 100 mm (4 inch) shield for
maximum 100 mm (4 inch) nozzle,
or optional 250 mm (10 inch) long
shield
• Optional rods and horn Refer to SITRANS LR200 Antennas
for optional rods and horns
Process connections
• Process connection 1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226],
or G 1½" [(BSPP), EN ISO 228-1]
(polypropylene rod antenna)
• Flange connection Refer to SITRANS LR200 Antennas
for more connections

Siemens FI 01 · 2015 4/199


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR200, Uni-Construction 7ML5422- Further designs
polypropylene rod antenna version 7777 0 Please add "-Z" to Article No. and specify Order
2-wire, 6 GHz pulse radar level transmitter for code(s).
continuous monitoring of liquids and slurries in
process vessels including high temperature and Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
pressure, to a range of 20 m (66 ft). Measuring-point number/identification
(max. 27 characters); specify in plain text
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F) Manufacturer's test certificate: M to DIN 55350, C11
Click on the Article No. for the online configura- Part 18 and to ISO 9000
tion in the PIA Life Cycle Portal. Namur NE43 compliant, device preset to failsafe N07
Enclosure/Cable inlet < 3.6 mA1)
Aluminum, epoxy painted Operating Instructions for HART/mA device Article No.
2 x ½" NPT 2
2 x M20x1.5 3 English A5E32337676
Polypropylene antenna type - German A5E34942758
(Max. 3 Bar pressure and 80 °C) Note: The Operating Instructions should be
1½" NPT [(Taper), ANSI/ASME B1.20.1], A
4
ordered as a separate line item on the order.
c/w integral 100 mm shield
R 1½" [(BSPT), EN 10226], B Multi-language Quick Start manual A5E31993614
c/w integral 100 mm shield This device is shipped with the Siemens Milltronics
G 1½" [(BSPP), EN ISO 228-1], C manual DVD containing the ATEX Quick Start and
c/w integral 100 mm shield Operating Instructions library.
1½" NPT [(Taper), ANSI/ASME B1.20.1], D Operating Instructions for PROFIBUS PA device
c/w integral 250 mm shield
R 1½" [(BSPT), EN 10226], E English A5E32337680
c/w integral 250 mm shield German A5E34942820
G 1½" [(BSPP), EN ISO 228-1], F
Note: The Operating Instructions should be
c/w integral 250 mm shield
ordered as a separate line item on the order.
Approvals
General Purpose, CE, R&TTE, RCM A Multi-language Quick Start manual A5E32153438
General Purpose, CSA, FM, Industry Canada, FCC B This device is shipped with the Siemens Milltronics
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A, C manual DVD containing the ATEX Quick Start and
B, C, D, E, F, G, Industry Canada Operating Instructions library.
Intrinsically Safe, FM Class I, II, Div. 1, Groups A, D Accessories
B, C, D, E, F, G, FCC Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4, E
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R HART modem/USB 7MF4997-1DB
Non incendive, FM Class I, Div. 2, Groups A, B, C, F (for use with a PC and SIMATIC PDM)
D, FCC1) One metallic cable gland M20x1.5, 7ML1930-1AP
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4 G rated -40 ... +80 °C (-40 ... +176 °F), HART2)
Ga/Gb, CE, R&TTE, RCM; GOST-R2)3)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/ H One metallic cable gland M20x1.5, 7ML1930-1AQ
Gb, CE, R&TTE, RCM; GOST-R3) rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA2)
Explosion Proof, CSA/FM Class I, II, III, Groups A, J One general purpose polymeric cable gland 7ML1930-1AM
B, C, D, E, F, G, Industry Canada, FCC1)3) M20x1.5, rated -20 ... + 80 °C (-40 ... +176 °F)
Communication/Output SITRANS RD100, loop powered display - 7ML5741-...
PROFIBUS PA 2 see Chapter 7
4 ... 20 mA, HART, start-up at < 3.6 mA 3
SITRANS RD200, universal input display with 7ML5740-...
1)
Available with enclosure option 2 only Modbus conversion - see Chapter 7
2)
Available with enclosure option 3 only SITRANS RD300, dual line display with totalizer 7ML5744-...
3)
Available with communication option 3 only and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1)
Available with communication option 3 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.

4/200 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LR200, Flange Adapter/PTFE Rod 7ML5423- SITRANS LR200, Flange Adapter/PTFE Rod 7ML5423-
Antenna Version Antenna Version
7 7 7 77 - 77 7 7 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for 2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in continuous monitoring of liquids and slurries in
process vessels including high temperature and process vessels including high temperature and
pressure, to a range of 20 m (66 ft). pressure, to a range of 20 m (66 ft).
Click on the Article No. for the online configura- 2 x ½" NPT 2
tion in the PIA Life Cycle Portal. 2 x M20x1.5 3
Antenna material (uses antenna adapter) Communication/Output
PTFE, uses antenna adapter and 1 PROFIBUS PA B
additional process connection below 4 ... 20 mA, HART, start-up at < 3.6 mA C
Process connection (refer to Pressure/ Approvals
Temperature curves, page 4/208) General Purpose, CE, R&TTE, RCM A
Flanges (316L stainless steel) General Purpose, CSA, FM, Industry Canada, FCC B
DN 50 PN 16, Type A, flat faced AA Intrinsically Safe, CSA Class I, II, Div. 1, C
DN 80 PN 16, Type A, flat faced BA Groups A, B, C, D, E, F, G, Industry Canada
DN 100 PN 16, Type A, flat faced
DN 150 PN 16, Type A, flat faced
CA
DA
Intrinsically Safe, FM Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, FCC
D 4
2" ASME 150 lb, flat faced FB Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4, E
3" ASME 150 lb, flat faced GB INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R
4" ASME 150 lb, flat faced HB Non incendive, FM Class I, Div. 2, Groups A, B, C, D, F
FCC2)
6" ASME 150 lb, flat faced JB
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4 G
DN 50 PN 40, flat faced AC Ga/Gb, CE, R&TTE, RCM; GOST-R 3)4)
DN 80 PN 40, flat faced BC Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/ H
DN 100 PN 40, flat faced CC Gb, CE, R&TTE, RCM; GOST-R4)
DN 150 PN 40, flat faced DC Explosion Proof, CSA/FM Class I, II, III, Groups A, J
2" ASME 300 lb, flat faced, available with FD B, C, D, E, F, G, Industry Canada, FCC2)4)
Pressure rating option 1 only due to flange hole Pressure rating
spacing Rating per Pressure/Temperature curves in manual 0
3" ASME 300 lb, flat faced GD 0.5 bar g (7.25 psi g) maximum 1
4" ASME 300 lb, flat faced HD
1)
6" ASME 300 lb, flat faced JD Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
JIS DN 50 10K AE 2)
Available with enclosure option 2 only
JIS DN 80 10K BE 3)
Available with enclosure option 3 only
JIS DN 100 10K CE 4)
Available with communication option C only
JIS DN 150 10K DE
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Threaded connection (316L stainless steel)
1½" NPT [(Taper), ANSI/ASME B1.20.1] LA
2" NPT [(Taper), ANSI/ASME B1.20.1] MA
R 1½" [(BSPT), EN 10226] LC
R 2" [(BSPT), EN 10226] MC
G 1½" [(BSPP), EN ISO 228-1] LE
G 2" [(BSPP), EN ISO 228-1] ME
Antenna extensions or Inactive shield length
No antenna extension 0
50 mm (2 inch) extension, PTFE 1
100 mm (4 inch) extension, PTFE 2
100 mm (4 inch) extension, 3
316L stainless steel shield1)
150 mm (6 inch) extension, 4
316L stainless steel shield1)
200 mm (8 inch) extension, 5
316L stainless steel shield1)
250 mm (10 inch) extension, 6
316L stainless steel shield1)
Process seal/gasket
Integral Gasket, 0
for flat faced flange process connections only,
not for Antenna extension options 3 ... 6
FKM O-ring, 1
not available for combination of flat faced flanges
with Antenna extension options 0, 1 or 2
Enclosure/Cable inlet
Aluminum, Epoxy painted

Siemens FI 01 · 2015 4/201


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
(max. 27 characters); specify in plain text
Manufacturer's test certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Namur NE43 compliant, device preset to failsafe N07
< 3.6 mA3)
Operating Instructions for HART/mA device Article No.
English A5E32337676
German A5E34942758

4 Note: The Operating Instructions should be


ordered as a separate line item on the order.
Multi-language Quick Start manual A5E31993614
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Operating Instructions for PROFIBUS PA device
English A5E32337680
German A5E34942820
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual A5E32153438
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
Antenna, rod, PTFE 7ML1830-1HC
Antenna extension, 50 mm (2 inch), PTFE 7ML1830-1CH
Antenna extension, 100 mm (4 inch), PTFE 7ML1830-1CG
HART modem / USB 7MF4997-1DB
(for use with PC and SIMATIC PDM)

Metallic cable gland M20 x 1.5, 7ML1930-1AP


rated -40 °C (-40 °F) ... 80 °C. (176 °F),
HART (two are required)
Metallic cable gland M20 x 1.5, 7ML1930-1AQ
rated -40 °C (-40 °F) ... 80 °C. (176 °F),
PROFIBUS PA (two required)
One General Purpose polymeric cable gland 7ML1930-1AM
M20 x 1.5, rating for -20°C (-4°F) ...+ 80°C. (176 °F)

SITRANS RD100, loop powered display - 7ML5741-...


see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section

4/202 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LR200, 7ML5425- SITRANS LR200, 7ML5425-
Flange adapter/Horn Antenna version 77 7 77 - 77 77 Flange adapter/Horn Antenna version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for 2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in continuous monitoring of liquids and slurries in
process vessels including high temperature and process vessels including high temperature and
pressure, to a range of 20 m (66 ft). pressure, to a range of 20 m (66 ft).
Click on the Article No. for the online configura- Process seal/gasket
tion in the PIA Life Cycle Portal. FKM (-40 ... +200 °C) 0
Antenna material (uses antenna adapter) Nitrile (-40 ... +60 °C), 1
316L stainless steel with PTFE cone emitter 0 sliding waveguide systems only
316L stainless steel with PTFE cone emitter and 1 FFKM (-35 ... +200 °C) 2
purge connection with 1/8" NPT inlet1) Enclosure/Cable inlet
Sliding waveguide system with 1 000 mm (40 inch) 2 Aluminum, Epoxy painted
waveguide1)2) 2 x ½" NPT 2
2 x M20x1.5 3
Process connection (refer to Pressure/
Temperature curves, page 4/209) Horn size/Waveguide options
Flanges (316L stainless steel) 80 mm (3 inch) horn4) B
DN 50 PN 16 EN 1092-1 Type A flat faced1)
DN 80 PN 16 EN 1092-1 Type A flat faced
AA
BA
100 mm (4 inch) horn4)
150 (6 inch) mm horn
C
D 4
DN 100 PN 16 EN 1092-1 Type A flat faced CA 200 (8 inch) mm horn E
DN 150 PN 16 EN 1092-1 Type A flat faced DA 100 mm (4 inch) horn with 100 mm (4 inch) F
DN 200 PN 16 EN 1092-1 Type A flat faced EA waveguide extension4)
DN 80 PN 10/16 DIN EN 1092-1 Type B1 raised face3) BF 100 mm (4 inch) horn with 150 mm (6 inch) G
DN 100 PN 10/16 DIN EN 1092-1 Type B1 raised face3) CF waveguide extension4)
DN 150 PN 10/16 DIN EN 1092-1 Type B1 raised face3) DF 100 mm (4 inch) horn with 200 mm (8 inch) H
DN 200 PN 16 DIN EN 1092-1 Type B1 raised face3) EF wave-guide extension4)
2" ASME 150 lb, flat faced1) FB 100 mm (4 inch) horn with 250 mm (10 inch) J
3" ASME 150 lb, flat faced GB waveguide extension4)
4" ASME 150 lb, flat faced HB 150 mm (6 inch) horn with 100 mm (4 inch) K
6" ASME 150 lb, flat faced JB waveguide extension
8" ASME 150 lb, flat faced KB 150 mm (6 inch) horn with 150 mm (6 inch) L
DN 50 PN 40, flat faced3) AC waveguide extension
DN 80 PN 40, flat faced3) BC 150 mm (6 inch) horn with 200 mm (8 inch) M
DN 100 PN 40, flat faced3) CC waveguide extension
DN 200 PN 40, flat faced3) EC 150 mm (6 inch) horn with 250 mm (10 inch) N
DN 80 PN 25/40 DIN EN 1092-1 Type B1 raised face3) CG waveguide extension
DN 100 PN 25/40 DIN EN 1092-1 Type B1 raised DG 200 mm (8 inch) horn with 100 mm (4 inch) P
face3) waveguide extension
DN 150 PN 25/40 DIN EN 1092-1 Type B1 raised EG 200 mm (8 inch) horn with 150 mm (6 inch) Q
face3) waveguide extension
2" ASME 300 lb, flat faced1)3) FD 200 mm (8 inch) horn with 200 mm (8 inch) R
3" ASME 300 lb, flat faced3) GD waveguide extension
4" ASME 300 lb, flat faced3) HD 200 mm (8 inch) horn with 250 mm (10 inch) S
waveguide extension
JIS DN 50 10K1) AE
(Add Order code Y01 and plain text:
JIS DN 80 10K BE "waveguide length ... mm")
JIS DN 100 10K CE
JIS DN 150 10K DE
JIS DN 200 10K EE
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Communication/Output
PROFIBUS PA 1
4 ... 20 mA, HART, start-up at < 3.6 mA 2

Siemens FI 01 · 2015 4/203


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR200, 7ML5425- Further designs
Flange adapter/Horn Antenna version 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order
2-wire, 6 GHz pulse radar level transmitter for code(s).
continuous monitoring of liquids and slurries in
process vessels including high temperature and Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
pressure, to a range of 20 m (66 ft). Measuring-point number/identification
(max. 27 characters); specify in plain text
Approvals
General Purpose, CE, R&TTE, RCM A Manufacturer's test certificate: M to DIN 55350, C11
General Purpose, CSA, FM, Industry Canada, FCC B Part 18 and to ISO 9000
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A, C Inspection Certificate Type 3.1 per EN 10204 C12
B, C, D, E, F, G, Industry Canada
Intrinsically Safe, FM Class I, II, Div. 1, Groups A, B, D Namur NE43 compliant, device preset to failsafe N07
C, D, E, F, G, FCC < 3.6 mA1)
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4, E Operating Instructions for HART/mA device Article No.
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; GOST-R
Non incendive, FM Class I, Div. 2, Groups A, B, C, D, F English A5E32337676
FCC5) German A5E34942758

4 Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4


Ga/Gb, CE, R&TTE, RCM; GOST-R6)7)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/Gb,
G

H
Note: The Operating Instructions should be
ordered as a separate line item on the order.
CE, R&TTE, RCM; GOST-R7) Multi-language Quick Start manual A5E31993614
Explosion Proof, CSA/FM Class I, II, III, Groups A, J This device is shipped with the Siemens Milltronics
B, C, D, E, F, G, Industry Canada, FCC5)7) manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Pressure rating
Rating per Pressure/Temperature curves in manual 0 Operating Instructions for PROFIBUS PA device
0.5 bar g (7.25 psi g) maximum 1
English A5E32337680
1)
Available with pressure rating option 1 only German A5E34942820
2)
Maximum Process Temperature 60 °C (140 °F)
Note: The Operating Instructions should be
3)
Available with Antenna Material option 0 and 1 only ordered as a separate line item on the order.
4)
For stillpipe applications only Multi-language Quick Start manual A5E32153438
5)
Available with enclosure option 2 only This device is shipped with the Siemens Milltronics
6)
Available with enclosure option 3 only manual DVD containing the ATEX Quick Start and
7) Operating Instructions library.
Available with communication option 2 only
Accessories
Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
HART modem/USB 7MF4997-1DB
(for use with a PC and SIMATIC PDM)
One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
One metallic cable gland M20x1.5, 7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA3)
One general purpose polymeric cable gland 7ML1930-1AM
M20x1.5, rated -40 ... +80 °C (-40 ... +176 °F)
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1)
Available with communication option 2 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
3)
Available with enclosure option 2 only

4/204 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200

■ Dimensional drawings
SITRANS LR200 with polypropylene PTFE rod antenna, threaded Threaded connection
shielded rod antenna PTFE rod, external shield

½” NPT cable entry


(or alternatively M20 x 1.5 cable gland)
Nameplate Nameplate
Threaded cover
187 (7.4)
187
(7.4)
Reference point
AISI 316, 18
17
Reference point 2” NPT, (0.7)
154 185 (0.67)
AISI 316, R 2” (BSPT)
(6) (7.3)
2” NPT, or G 2” (BSPP)
S.L.
Enclosure/ R 2” (BSPT) Antenna shield
electronics or G 2” (BSPP) (inactive length)
158
PTFE AISI 316
(6.1) 412

4
Locking ring antenna Active antenna L
(16.3)
Reference point (PTFE)
Std. 296 (11.7) min. Shield Length (S.L.):
Option: 446 (17.6) max. Mounting Shield length (internal): min. 100 (4)
thread Standard: 100 (4) (customer specified)
Optional: 250 (10)
Overall Length (L):
Polypropylene 374 (14.7) plus
rod antenna shielded length
Std. 575 (22.6) min.
Option: 725 (28.5) max.

Horn antenna with flat faced flange


Enclosure/electronics

Sliding waveguide 187 Nameplate


(7.4)
Locking ring
Reference point
Flange

Nameplate
Ø80 (3) 131
187 Horn (5.16)
100 225.8
(7.4) (8.89) 325.1
(4)
Reference point (12.79)

40 150 (6)
(1.6) 200 (8)
Sliding flange

1 000
934 (40.8)
(36.8)

111
(4.40)
206
100 (4) (8.11)
305
(12.01)
150 (6)

200 (8)

Fully inserted length =


934 mm + horn height

SITRANS LR200, dimensions in mm (inch)

Siemens FI 01 · 2015 4/205


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200

■ Schematics
Connect the wires to the Hand programmer
terminals as shown: the
polarity is identified on the
terminal block.

4 Shield for HART and Part number:


7ML1930-1BK
PROFIBUS PA
Gland
intrinsically safe
versions only.

Notes:
1. DC terminal shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR200 connections

4/206 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas

■ Integration

Horn with waveguide


extension. Used for high
temperature isolation, long
standpipes, and clearing
tank obstructions. Flat faced flange Shielded rod antenna

4
connection with with a stainless steel
PTFE rod antenna. shield eliminates
standpipe interference.
Various lengths
available.

Sliding waveguide antenna, SITRANS LR200 with flange


typically for digester applications adapter for connection to
that include an isolation valve optional antennas.
between the instrument and the vessel.

Antenna configurations for SITRANS LR200

■ Technical specifications
Antenna Types Flat Faced Flange with Rod Shielded Rod Horn (4", 6", 8" sizes available)
Connection type Flat faced flange Threaded 2" NPT, R 2" (BSPT), Flat faced flange
nominal pipe sizes 50, 80, 100, G 2" (BSPP) or flat faced flange nominal pipe sizes 50, 80, 100,
150 mm (2, 3, 4, 6 inch) nominal pipe sizes 80, 100 mm 150 mm (2, 3, 4, 6 inch)
(3, 4 inch)
Wetted parts PTFE PTFE, 316L stainless steel, FKM o-ring 316L stainless steel
PTFE, FKM o-ring
Extensions 50 or 100 mm (2 or 4 inch) 100, 150, 200 or 250 mm Use waveguide for extensions to 6 m
PTFE or UHMW-PE (4, 6, 8 or 10 inch) (20 ft) long
standard shield length
Dielectric constant >3 >3 >3
Insertion length (max.) 41 cm (16.3 inch) Variable Variable with extension

Purging option (liquid or gas) No No Yes


Sliding waveguide option for Yes No Yes
digesters1)
Weight2) 6.5 kg (14.3 lb) 5.0 kg (11 lb) 7.5 kg (16.5 lb)
1)
Maximum pressure 0.5 bar g at 60 °C (7.25 psi g at 140 °F)
2)
Not including extensions, includes SITRANS LR200 and smallest process connection

Siemens FI 01 · 2015 4/207


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas

■ Characteristic curves
Maximum flange and process temperatures versus allowable ambient temperature

90
Ambient temperature (°C)

130 °C
80
70
67 °C
60
50
Polypropylene rod PTFE rod/
40 horn antenna
30
20

4
10

0
0 20 40 60 80 100 120 140 160 180 200 220
Process flange surface temperature (°C)

SITRANS LR200 Ambient/Process Flange Surface Temperature Curve

4/208 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Antennas

PTFE rod antenna with


integral gasket 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0

14.0
(A)
(B)
Pressure (bar, gauge)

12.0

10.0
(C)
8.0

6.0

4.0 (A) 22452 50 mm/2 inch nom.

2.0 (B) 22452 80 mm/3 inch nom.

0.0 (C) 22452 100 mm/4 inch nom.


-40 -20 0 20 40 60 80 100 120 140 160 180 200
Temperature (°C) 4
Horn antenna and/or wave guide with
PTFE ermitter 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0
(E)
14.0
(D)
Pressure (bar, gauge)

12.0

10.0
(F)
8.0

6.0 (G) (D) 22452 80 mm/3 inch nom.


4.0 (E) 22452 100 mm/4 inch nom.

2.0 (F) 22452 150 mm/6 inch nom.

0.0 (G) 22452 200 mm/8 inch nom.


-50 0 50 100 150 200
Temperature (°C)

Threaded process
1.5" & 2" NPT, BSP, & G
40.0

35.0
Pressure (bar, gauge)

30.0

25.0
(H) 1.5" and 2", thread connection
20.0

15.0

10.0
(H)
5.0

0.0
-50 0 50 100 150 200
Temperature (°C)

SITRANS LR200 Process Pressure/Temperature derating curves

Siemens FI 01 · 2015 4/209


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials

■ Selection and ordering data


SITRANS LR200 Specials SITRANS LR200 Specials
Article No. Article No.
SITRANS LR200 PROFIBUS PA Aluminum SITRANS LR200 aluminum enclosure A5E03617085
Enclosure Kit with electronics and covers with board stack, LUI display, 5.8 GHz, NPT
(7ML5422, 7ML5423, 7ML5424, 7ML5425), cable inlet, approval option A, with HART
calibrated for use with standard rod antenna communication start-up at < 3.6 mA,
no process connection.5)
SITRANS LR200 aluminum enclosure A5E03617086
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option B, with HART
SITRANS LR200 aluminum enclosure A5E01483420 communication start-up at < 3.6 mA,
with board stack, LUI display, 5.8 GHz, M20 no process connection.5)
cable inlet, approval option E, with PROFIBUS SITRANS LR200 aluminum enclosure A5E03617087
PA communication, no process connection.5) with board stack, LUI display, 5.8 GHz, NPT
SITRANS LR200 aluminum enclosure A5E01483440 cable inlet, approval option C, with HART

4 with board stack, LUI display, 5.8 GHz, M20 communication start-up at < 3.6 mA,
cable inlet, approval option A, with PROFIBUS no process connection.5)
PA communication, no process connection.5) SITRANS LR200 aluminum enclosure A5E03617088
SITRANS LR200 aluminum enclosure A5E01483456 with board stack, LUI display, 6.3 GHz, NPT
with board stack, LUI display, 6.3 GHz, M20 cable inlet, approval option E, with HART
cable inlet, approval option C, with PROFIBUS communication start-up at < 3.6 mA,
PA communication, no process connection.5) no process connection.5)
SITRANS LR200 aluminum enclosure A5E01483547 SITRANS LR200 Horn Antenna Kits
with board stack, LUI display, 6.3 GHz, NPT with mounting screws
cable inlet, approval option C, with PROFIBUS (no emitter supplied)
PA communication, no process connection.5)
SITRANS LR200 aluminum enclosure A5E01483559
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.5)
80 mm (3 inch) horn antenna kit PBD:25500K02A
SITRANS LR200 HART aluminum enclosure
kit with electronics and covers (7ML5422, 100 mm (4 inch) horn antenna kit PBD:25500K03A
7ML5423, 7ML5424, 7ML5425), calibrated for
use with standard rod antenna 150 mm (6 inch) horn antenna kit PBD:25500K05A
200 mm (8 inch) horn antenna kit PBD:25500K07A
SITRANS LR200 Extension Kits for
Horn Antenna with mounting screws
100 mm (4 inch) extension kit for horn antenna PBD:25501K0100A
SITRANS LR200 aluminum enclosure A5E02956419
with board stack, LUI display, 5.8 GHz, M20 150 mm (6 inch) extension kit for horn antenna PBD:25501K0150A
cable inlet, approval option A, with HART
communication start-up at < 3.6 mA, 200 mm (8 inch) extension kit for horn antenna PBD:25501K0200A
no process connection.5) 250 mm (10 inch) extension kit for horn antenna PBD:25501K0250A
SITRANS LR200 aluminum enclosure A5E02956420 500 mm (20 inch) extension kit for horn antenna PBD:25501K0500A
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with HART 1 000 mm (40 inch) extension kit for PBD:25501K1000A
communication start-up at < 3.6 mA, horn antenna
no process connection.5) SITRANS LR200 Flanged Rod Antenna Kit
SITRANS LR200 aluminum enclosure A5E02956421 with 316L stainless steel flat faced flanges
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option G, with HART
communication start-up at < 3.6 mA,
no process connection.5)
SITRANS LR200 aluminum enclosure A5E02956422
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option H, with HART Flanged PTFE rod antenna kit, 2" ASME, 150 lb. PBD:
communication start-up at < 3.6 mA, See drawing 51003 on 51003K020AAAA
no process connection.5) http://www.siemens.com/radar1)4)
Flanged PTFE rod antenna kit, DN 50 PN 16. PBD:
See drawing 51003 on 51003K050AJAA
http://www.siemens.com/radar1)4)
Flanged PTFE rod antenna kit, PBD:
JIS 10K DN 50. See drawing 51003 on 51003K050AOAA
http://www.siemens.com/radar1)4)

4/210 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials SITRANS LR200 Specials
Article No. Article No.
SITRANS LR200 PTFE Rod Antenna Kit with SITRANS LR200 PTFE Rod Antenna Kit
316L stainless steel 1½"pipe thread process (100 mm shield) with 316L stainless steel
connection 2" pipe thread process connection

PTFE rod antenna kit, 1½" NPT 316L stainless PBD: PTFE rod antenna shielded kit, 2" NPT 316L PBD:
steel process connection, FKM O-ring; 51004K1AAA stainless steel process connection, 51002K0100AAA
See drawing 51004 on FKM O-ring, 100 mm 316L stainless steel
http://www.siemens.com/radar4) shield. See drawing 51002 on
http://www.siemens.com/radar3)4)
PTFE rod antenna kit, R 1½" (BSPT), PBD:
EN 10226 316L stainless steel process connec- 51004K2AAA PTFE rod antenna shielded kit, R 2" (BSPT), PBD:
tion, FKM O-ring; see drawing 51004 on EN 10226 316L stainless steel process connec- 51002K0100BAA
http://www.siemens.com/radar4)
PTFE rod antenna kit, 1½" G 316L stainless PBD:
tion, FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar3)4)
4
steel process connection, FKM O-ring; 51004K3AAA
see drawing 51004 on PTFE rod antenna shielded kit, 2" G 316L PBD:
http://www.siemens.com/radar4) stainless steel process connection, 51002K0100CAA
FKM O-ring, 100 mm 316L stainless steel
SITRANS LR200 PTFE Rod Antenna Kit with shield. See drawing 51002 on
316L stainless steel 2" pipe thread process http://www.siemens.com/radar3)4)
connection
SITRANS LR200 Horn Antenna Kit with 316L
stainless steel flat faced flange, with PTFE
emitter (without waveguide)

PTFE rod antenna kit, 2" NPT 316L stainless PBD:


steel process connection, FKM O-ring; 51005K1AAA
see drawing 51005 on Horn antenna kit, 2" ASME 316L stainless steel PBD:
http://www.siemens.com/radar4) flange 3" horn, PTFE emitter1)4) 51006K020AAAA
PTFE rod antenna kit, R 2" (BSPT), PBD: Horn antenna kit, 2" ASME 316L stainless steel PBD:
EN 10226 316L stainless steel process connec- 51005K2AAA flange 4" horn, PTFE emitter1)2) 51006K020AABA
tion, FKM O-ring; see drawing 51005 on
Horn antenna kit, 2" ASME 316L stainless steel PBD:
http://www.siemens.com/radar4)
flange 6" horn, PTFE emitter1)2) 51006K020AACA
PTFE rod antenna kit, 2" G 316L stainless steel PBD:
Horn antenna kit, 2" ASME 316L stainless steel PBD:
process connection, FKM O-ring; 51005K3AAA
flange 8" horn, PTFE emitter1)2) 51006K020AADA
see drawing 51005 on
http://www.siemens.com/radar4) Horn antenna kit, DN 50 PN 16 316L stainless PBD:
steel flange 80 mm horn, PTFE emitter1)2) 51006K050AJAA
Horn antenna kit, DN 50 PN 16 316L stainless PBD:
steel flange 100 mm horn, PTFE emitter1)2) 51006K050AJBA
Horn antenna kit, DN 50 PN 16 316L stainless PBD:
steel flange 150 mm horn, PTFE emitter1)2) 51006K050AJCA
Horn antenna kit, DN 50 PN 16 316L stainless PBD:
steel flange 200 mm horn, PTFE emitter1)2) 51006K050AJDA

Siemens FI 01 · 2015 4/211


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials SITRANS LR200 Specials
Article No. Article No.
SITRANS LR200 PTFE flanged rod antenna PTFE paste
kit with 316L stainless steel shield and 316L
stainless steel flat faced flange Kit, PTFE paste, Tube, 250 mL PBD:51036065
Cable gland
One polymeric cable gland M20x1.5, 7ML1930-1AN
rated -20 ... +80 °C (-4 ... +176 °F) for
General Purpose and ATEX EEx e
One metallic cable gland M20x1.5, 7ML1930-1AP
PTFE shielded rod antenna kit, flanged, PBD: rated -40 ... +80 °C (-40 ... +176 °F), HART
3" ASME 150 lb 316L stainless steel flange, 51014K0100AAA
100 mm 316L stainless steel shield.1)4) One metallic cable gland M20x1.5, 7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F),
PTFE shielded rod antenna kit, flanged, PBD: PROFIBUS PA
DN 80 PN 16 316L stainless steel flange, 51014K0100EJA
100 mm 316L stainless steel shield.1)4) Please contact ceg.smpi@siemens.com for special requests.
1)
PTFE shielded rod antenna kit, flanged, PBD: Available in flange sizes including ASME, DIN and JIS:

4 3" ASME 150 lb 316L stainless steel flange,


150 mm 316L stainless steel shield.1)4)
51014K0150AAA
2)
please contact ceg.smpi@siemens.com.
Available with no pressure rating
3)
PTFE shielded rod antenna kit, flanged, PBD: Available in other shield lengths:
DN 80 PN 16 316L stainless steel flange, 51014K0150EJA please contact ceg.smpi@siemens.com.
4)
150 mm 316L stainless steel shield.1)4) Available with Pressure rating; serial number of original
unit required with completed Application Questionnaire found
PTFE shielded rod antenna kit, flanged, PBD: on page 4/193.
3" ASME 150 lb 316L stainless steel flange, 51014K0200AAA
200 mm 316L stainless steel shield.1)4)
PTFE shielded rod antenna kit, flanged, PBD:
DN 80 PN 16 316L stainless steel flange, 51014K0200EJA
200 mm 316L stainless steel shield.1)4)
PTFE shielded rod antenna kit, flanged, PBD:
3" ASME 150 lb 316L stainless steel flange, 51014K0250AAA
250 mm 316L stainless steel shield.1)4)
PTFE shielded rod antenna kit, flanged, PBD:
DN 80 PN 16 316L stainless steel flange, 51014K0250EJA
250 mm 316L stainless steel shield.1)4)

4/212 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

■ Overview ■ Configuration
Installation

Note:
• Beam angle is the width of the beam width:
cone where the energy density 1.5 horn = 19°
is half of the peak energy 2.0 horn = 15°
density. 3.0 horn = 10°
• The peak energy density is 4.0 horn = 8°
directly in front of and in line
with the horn antenna. 19°
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
• Use largest possible antenna.
4
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter Mounting unit on bypass Mounting unit on
for continuous monitoring of liquids and slurries in storage and stilling well
process vessels including high temperature and pressure,
to a range of 20 m (66 ft). Orient front or back of Orient front or back of device
device toward vent. toward stillpipe slots.
■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small antennas for easy
mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna Use largest
horn size
• Communication using HART, PROFIBUS PA, possible in
or FOUNDATION Fieldbus pipe.
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM, Emerson
AMS, or Field Device Tools, such as PACTware or Fieldcare via
SITRANS DTM Mounting unit on vessel Mounting on a nozzle
• Functional Safety (SIL 2). Device suitable for use in accor-
dance with IEC 61508 and IEC 61511
• 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1
Min. 10 (0.4)

■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller horn antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple SITRANS LR250 installation, dimensions in mm (inch)
programming using the Intrinsically Safe handheld programmer
without saving to open the instrument’s lid.
SITRANS LR250 measures superbly on low dielectric media,
and in small vessels, as well as tall and narrow vessels.
• Key Applications: liquid bulk storage tanks, process vessels,
vaporous liquids, high temperatures, low dielectric media and
applications with functional safety requirements

Siemens FI 01 · 2015 4/213


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

■ Technical specifications
Mode of operation Process connections
Measuring principle Radar level measurement • Process connection 1½", 2" or 3" NPT [(Taper),
ANSI/ASME B1.20.1]
Frequency K-band (25.0 GHz) R 1½", 2" or 3" [(BSPT),
Minimum measuring range 50 mm (2 inch) from end of antenna EN 10226]

Maximum measuring range 20 m (65 ft), antenna dependent G 1½", 2" or 3" [(BSPP),
EN ISO 228-1]
Output • Flange connection 2", 3", 4" (ANSI 150, 300 lb),
HART: Version 5.1 50, 80, 100 mm (PN 16, 40, JIS 10K)
• Analog output 4 ... 20 mA
Power supply
• Accuracy ± 0.02 mA
• Fail-safe • Programmable as high low or hold 4 ... 20 mA/HART Nominal 24 V DC (max. 30 V DC) with
(loss of echo) max. 550 
• NE 43 programmable
PROFIBUS PA • 15 mA
PROFIBUS PA: Profile 3.01 • Per IEC 61158-2
• Function blocks 2 Analog Input (AI)
FOUNDATION Fieldbus • 20.0 mA
FOUNDATION Fieldbus H1
4
• Per IEC 61158-2
• Functionality Basic or LAS
• Version ITK 5.2.0 Certificates and approvals
• Function blocks 2 Analog Input (AI) General CSAUS/C, CE, FM, NE 21, RCM
Performance (according to refer- Radio FCC, Industry Canada and
ence conditions IEC60770-1) Europe ETSI EN 302-372, RCM
Maximum measured error 3 mm (0.118 inch) Hazardous
Influence of ambient temperature < 0.003 %/K • Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
Rated operating conditions • Increased Safety (Brazil) INMETRO Ex e ia mb IIC T4 Ga/Gb,
Installation conditions Ex ia ta IIIC T100 °C Da
• Location Indoor/outdoor • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
Ambient conditions (enclosure) • Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1,
• Ambient temperature -40 ... +80 °C (-40 ... +176 °F) Groups A, B, C, D; Class II, Div. 1,
• Installation category I Groups E, F, G; Class III T4
• Pollution degree 4 • Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Medium conditions Groups E, F, G; Class III T4
Dielectric constant r > 1.6, antenna and application • Non-incendive (Canada/USA) CSA/FM Class I, Div. 2,
dependent Groups A, B, C, D T5
• Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T4 Ga/Gb,
Process temperature -40 ... +200 °C (-40 ... +392 °F) (China) Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
(at process connection with T90 IP67 DIP A20 TA90 ºC
FKM O-ring)
• Intrinsically Safe (China) NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
-20 ... +200 °C (-4 ... +392 °F) IP67 DIP A20 TA90 ºC
(at process connection with • Non-sparking (China) NEPSI Ex nA IIC T4 Gc
FFKM O-ring)
• Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 Ga
Process pressure Up to 40 bar g (580 psi g), process ATEX II 1D Ex ia IIIC T100 °C Da
connection and temperature depen- • Non-sparking (Europe) ATEX II 3G Ex nA IIC T4 Gc
dent. • Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D,
See Pressure/Temperature curves for Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
more information T100 °C Da
Design • Increased Safety IECEx/ATEX II 1/2 GD, 1D, 2D,
Enclosure (International/Europe) Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
• Material Aluminum, polyester powder-coated T100 °C Da
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT • Intrinsically Safe (International) IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEX/ATEX II 1D Ex ia ta IIC T100 °C
Degree of protection Type 4X/NEMA 4X, Type 6/NEMA 6, Da
IP67, IP68
• Explosion Proof (Russia) GOST-R Ex d
Weight < 3 kg (6.6 lb) 3.75 mm (1½ inch)
threaded connection with 1½" horn • Increased Safety (Russia) GOST-R Ex e
antenna • Intrinsically Safe (Russia) GOST-R Ex ia
Display (local) Graphic local user interface including • Marine • Lloyd's Register of Shipping
quick start wizard and echo profile • ABS Type Approval
display • Bureau Veritas
Antenna • Functional Safety SIL-2 suitable in accordance with
• Material 316L stainless steel [optional alloy IEC 61508/61511
N06022/2.4602
(Hastelloy C-22 or equivalent)]
• Dimensions (nominal horn sizes) Standard 1.5 inch (40 mm),
2 inch (48 mm), 3 inch (75 mm),
4 inch (95 mm) horn and optional
100 mm (4 inch) horn extension

4/214 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Programming
• Intrinsically Safe Siemens handheld Infrared receiver
programmer
- Approvals for handheld IS model:
programmer ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = +50 °C
IECEx SIR 09.0073
• Handheld communicator HART communicator 375/475
• PC • SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or
Fieldcare)
• Display (local) Graphic local user interface including
quick start wizard and echo profile
displays

Siemens FI 01 · 2015 4/215


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LR250 horn antenna 7ML5431- SITRANS LR250 horn antenna 7ML5431-
2-wire, 25 GHz pulse radar level transmitter for 7 7 7 7 0 - 777 7 2-wire, 25 GHz pulse radar level transmitter for 7 7 7 7 0 - 777 7
continuous monitoring of liquids and slurries in continuous monitoring of liquids and slurries in
storage and process vessels including high storage and process vessels including high
temperature and pressure, to a range of 20 m temperature and pressure, to a range of 20 m
(66 ft) (antenna dependent). Ideal for small vessels (66 ft) (antenna dependent). Ideal for small vessels
and low dielectric media. and low dielectric media.
Click on the Article No. for the online configura- Flanged connection Hastelloy C
tion in the PIA Life Cycle Portal. 2" Class 150 ASME B16.5 raised faced4) JA
Process Connection and Antenna Material 3" Class 150 ASME B16.5 raised faced4) JB
316L (1.4435 or 1.4404) stainless steel, ¢ 0 4" Class 150 ASME B16.5 raised faced4) JC
PTFE emitter, FKM seal1) 2" Class 300 ASME B16.5 raised faced4) JD
316L (1.4435 or 1.4404) stainless steel, ¢ 1 3" Class 300 ASME B16.5 raised faced4) JE
PTFE emitter, FFKM seal1) 4" Class 300 ASME B16.5 raised faced4) JF
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter, 2
DN 50 PN 16 EN 1092-1 Type B1 raised faced4) KA
FKM seal2)
DN 80 PN 16 EN 1092-1 Type B1 raised faced4) KB
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter, 3
DN 100 PN 16 EN 1092-1 Type B1 raised faced4) KC
FFKM seal2)
4 Process Connection Type
Threaded connection 316L
DN 50 PN 40 EN 1092-1 Type B1 raised faced4)
DN 80 PN 40 EN 1092-1 Type B1 raised faced4)
KD
KE
DN 100 PN 40 EN 1092-1 Type B1 raised faced4) KF
1½" NPT (ASME B1.20.1) (tapered thread)3) ¢ AA
R 1½" [(BSPT), EN 10226-1] (tapered thread)3) ¢ AB 50A 10K JIS B 2220 raised faced4) LA
G 1½" [(BSPP), EN ISO 228-1] ¢ AC 80A 10K JIS B 2220 raised faced4) LB
(parallel thread)3) 100A 10K JIS B 2220 raised faced4) LC
2" NPT (ASME B1.20.1) (tapered thread) ¢ AD DN 50 PN 16 EN 1092-1 Type B1 raised face MA
R 2" [(BSPT), EN 10226-1] (tapered thread) ¢ AE DN 80 PN 16 EN 1092-1 Type B1 raised face MB
G 2" [(BSPP), EN ISO 228-1] (parallel thread) ¢ AF DN 100 PN 16 EN 1092-1 Type B1 raised face MC
3" NPT (ASME B1.20.1) (tapered thread) AG DN 150 PN 16 EN 1092-1 Type B1 raised face MD
R 3" [(BSPT), EN 10226-1] (tapered thread) AH DN 50 PN 40 EN 1092-1 Type B1 raised face ME
G 3" [(BSPP), EN ISO 228-1] (parallel thread) AJ DN 80 PN 40 EN 1092-1 Type B1 raised face MF
Flanged connection 316L DN 100 PN 40 EN 1092-1 Type B1 raised face MG
2" Class 150 ASME B16.5 flat faced4) ¢ BA DN 150 PN 40 EN 1092-1 Type B1 raised face MH
3" Class 150 ASME B16.5 flat faced4) ¢ BB Communication/Output
4" Class 150 ASME B16.5 flat faced4) ¢ BC PROFIBUS PA ¢ 1
2" Class 300 ASME B16.5 flat faced4) CA 4 ... 20 mA, HART, start-up at < 3.6 mA ¢ 2
3" Class 300 ASME B16.5 flat faced4) CB FOUNDATION Fieldbus ¢ 3
4" Class 300 ASME B16.5 flat faced4) CC Enclosure/Cable inlet
DN 50 PN 16 EN 1092-1 Type A flat faced4) ¢ DA Aluminum, Epoxy painted
DN 80 PN 16 EN 1092-1 Type A flat faced4) ¢ DB 2 x ½" NPT ¢ 0
DN 100 PN 16 EN 1092-1 Type A flat faced4) ¢ DC 2 x M20x1.5 ¢ 1
DN 50 PN 40 EN 1092-1 Type A flat faced4) EA Antenna
DN 80 PN 40 EN 1092-1 Type A flat faced4) EB 1½" horn ¢ A
DN 100 PN 40 EN 1092-1 Type A flat faced4) EC 2" horn (fits 2" ASME or DN 50 nozzles) ¢ B
50A 10K JIS B 2220 flat faced4) ¢ FA 3" horn (fits 3" ASME or DN 80 nozzles) ¢ C
80A 10K JIS B 2220 flat faced4) ¢ FB 4" horn (fits 4" ASME or DN 100 nozzles) ¢ D
100A 10K JIS B 2220 flat faced4) ¢ FC 1½" horn with 100 mm extension ¢ E
DN 50 PN 16 DIN EN 1092-1 Type B1 raised face GA 2" horn with 100 mm extension ¢ F
DN 80 PN 16 DIN EN 1092-1 Type B1 raised face GB 3" horn with 100 mm extension ¢ G
DN 100 PN 16 DIN EN 1092-1 Type B1 raised face GC 4" horn with 100 mm extension ¢ H
DN 150 PN 16 DIN EN 1092-1 Type B1 raised face GD Hastelloy C22 (or equivalent)
DN 50 PN 40 DIN EN 1092-1 Type B1 raised face HA 2" horn (fits 2" ASME or DN 50 nozzles) J
DN 80 PN 40 DIN EN 1092-1 Type B1 raised face HB 3" horn (fits 3" ASME or DN 80 nozzles) K
DN 100 PN 40 DIN EN 1092-1 Type B1 raised face HC 4" horn (fits 4" ASME or DN 100 nozzles) L
DN 150 PN 40 DIN EN 1092-1 Type B1 raised face HD 2" horn (fits 2" ASME or DN 50 nozzles) with M
100 mm extension
3" horn (fits 3" ASME or DN 80 nozzles) with N
100 mm extension
4" horn (fits 4" ASME or DN 100 nozzles) with P
100 mm extension

4/216 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Selection and Ordering data Article No.
SITRANS LR250 horn antenna 7ML5431-
2-wire, 25 GHz pulse radar level transmitter for 7 7 7 7 0 - 777 7
continuous monitoring of liquids and slurries in
storage and process vessels including high
temperature and pressure, to a range of 20 m
(66 ft) (antenna dependent). Ideal for small vessels
and low dielectric media.
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM¢ A
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢ B
B, C, D, Class II, Div.1, Groups E,F, G, Class III T4
FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4 ¢ C
Ga, IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da,
o
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 C Da,
CE, R&TTE, RCM
Non-incendive: CSA/FM Class I, Div. 2, Groups A, ¢ D
B, C, D T5, FCC, Industry Canada
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE, ¢ E
4
R&TTE, RCM
Increased Safety: IECEx/ATEX II 1/2 GD,1D, ¢ F
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM5)
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢ G
ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM5)
Explosion proof: CSA/FM Class I, II and III, Div.1, ¢ H
Groups A, B, C, D, E, F, G, FCC, Industry Canada5)
Non Sparking: NEPSI Ex nA IIC T4 Gc ¢ K
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, ¢ L
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, ¢ M
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC5)
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢ N
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC5)
Pressure rating
Rating per Pressure/Temperature curves in manual ¢ 0
0.5 bar g (7.25 psi g) maximum ¢ 1
1) Available with process connection options AA ... HD & Antenna
Versions A ... H only
2) Available with process connection options JA ... MH & Antenna
Versions J ... P only
3) Available For antenna versions A and E only, max. range 10 m (32.8 ft),
dk > 3. Can measure dk >1.6 [20 m (65.6 ft)] when mounted in a stillpipe/
bypass.
4) Siemens Milltronics type flange (flange bolting patterns and facings
dimensionally correspond to the applicable ASME B16.5, or EN 1092-1,
or JIS B 2220 standard), see operating instructions for details
5)
Applicable with communication option 2 only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/217


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Operating Instructions for
FOUNDATION Fieldbus device
Please add "-Z" to Article No. and specify Order
code(s). English A5E32221411
Plug M12 with mating Connector1)2)3) ¢ A50 German A5E32376112
Plug 7/8" with mating Connector2)3)4) ¢ A55 Note: The Operating Instructions should be
ordered as a separate line item on the order.
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification Compact Operating Instructions for
(max. 27 characters); specify in plain text FOUNDATION Fieldbus device
Manufacturer's Test Certificate: M to DIN 55350, ¢ C11 English, French, German, Spanish, Italian, Dutch, A5E33472700
Part 18 and to ISO 9000 Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
Inspection certificate 3.1 of EN 10204 ¢ C12
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472738
Functional Safety (SIL 2). Device suitable for use in ¢ C20 Latvian, Lithuanian, Polish, Romanian, Slovakian,
accordance with IEC 61508 and IEC 615113)5) Slovenian
Namur NE43 compliant, device preset to failsafe ¢ N07 This device is shipped with the Siemens Milltronics
4 < 3.6 mA5)
Operating Instructions for HART/mA device Article No.
manual DVD containing the ATEX Compact Operat-
ing Instructions and Operating Instructions library.

English A5E32220602 Accessories

German A5E32376088 Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK


Note: The Operating Instructions should be HART modem/USB 7MF4997-1DB
ordered as a separate line item on the order. (for use with a PC and SIMATIC PDM)
Compact Operating Instructions for HART/mA One metallic cable gland M20x1.5, 7ML1930-1AP
device rated -40 ... +80 °C (-40 ... +176 °F),
HART (two are required)
English, French, German, Spanish, Italian, Dutch, A5E33469191
Danish, Finnish, Greek, Portuguese (Portugal), One metallic cable gland M20x1.5, 7ML1930-1AQ
Swedish rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
and FOUNDATION Fieldbus (two are required)6)
English, Bulgarian, Czech, Estonian, Hungarian, A5E33469171
Latvian, Lithuanian, Polish, Romanian, Slovakian, FDA approved FKM o-ring for 2" G (BSPP) process 7ML1830-3AN
Slovenian connections -28 ... +80 °C (-28 ... +176 °F)
This device is shipped with the Siemens Milltronics SITRANS RD100, loop powered display - 7ML5741-...
manual DVD containing the ATEX Compact Operat- see Chapter 7
ing Instructions and Operating Instructions library. SITRANS RD200, universal input display with 7ML5740-...
Operating Instructions for PROFIBUS PA device Modbus conversion - see Chapter 7
English A5E32221386 SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
German A5E32376094 see Chapter 7
Note: The Operating Instructions should be SITRANS RD500 web, universal remote monitoring 7ML5750-...
ordered as a separate line item on the order. solution for instrumentation - see Chapter 7
Compact Operating Instructions for For applicable back up point level switch -
PROFIBUS PA device see point level measurement section
English, French, German, Spanish, Italian, Dutch, A5E33469239 1)
Danish, Finnish, Greek, Portuguese (Portugal), Available with enclosure option 1 only
2)
Swedish To be used with communication options 1 and 3 only.
Connector has IP67 rating.
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472685 3)
Latvian, Lithuanian, Polish, Romanian, Slovakian, Available with approval options A and B. Available with approval option C
Slovenian for use on intrinsically safe applications only. Not rated for dust Ex.
4)
Available with enclosure option 0 only
This device is shipped with the Siemens Milltronics 5)
manual DVD containing the ATEX Compact Operat- Applicable to communication option 2 only
6)
ing Instructions and Operating Instructions library. For use with communication option 1 and 3 only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/218 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

■ Characteristic curves
Maximum flange and process temperatures versus allowable ambient temperature

90
Ambient temperature (°C)

130 °C
80
70
65 °C
60
50

40
30
20

4
10

0
0 20 40 60 80 100 120 140 160 180 200 220
Process flange surface temperature (°C)

SITRANS LR250 Ambient/Process Flange Surface Temperature Curve

Siemens FI 01 · 2015 4/219


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

■ Dimensional drawings
Threaded Horn Antenna

50 ½" NPT cable entry


(2.0) (or alternatively,
M20 cable gland)

Threaded cover

167 (6.6)
154 (6.1) 90 (3.5)

Enclosure/
electronics
196 (7.7)

(6.26)
159
Retaining
collar

Process Sensor reference


device tag point

Horn
28 (1.1)*

See dimension
table for height to
sensor reference
point
Antenna Antenna
O.D. O.D.

*28 mm (1.1) for 1.5 inch and 2 inch, 42 mm (1.65) for 3 inch
Antenna Antenna O.D. Height to sensor reference point Beam angle Measurement
Type range
1-1/2" threaded 2" threaded 3" threaded
connection connection connection
1.5" horn 39.8 (1.57) 135 (5.3) N/A N/A 19 degrees 10 m (32.8 ft)
2" horn 47.8 (1.88) N/A 166 (6.55) 180 (7.09) 15 degrees 20 m (65.6 ft)
3" horn 74.8 (2.94) N/A 199 (7.85) 213 (8.39) 10 degrees 20 m (65.6 ft)
4" horn 94.8 (3.73) N/A 254 (10) 268 (10.55) 8 degrees 20 m (65.6 ft)

SITRANS LR250 Threaded Horn Antenna, dimensions in mm (inch)

4/220 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

Threaded Horn Antenna with Extension


50 ½" NPT cable entry
(2.0) (or alternatively,
M20 cable gland)

Threaded cover

167
154 (6.1) (6.6)
90 (3.5)
4
Enclosure/
electronics
Retaining
(7.7)
196

collar

(6.26)
159
Sensor reference
point
28 (1.1)*

Process
device tag

Horn
See dimension
table for height to
sensor reference
point
Antenna
Antenna O.D.
O.D.

*28 mm (1.1) for 1.5 inch and 2 inch, 42 mm (1.65) for 3 inch
Antenna Antenna O.D. Height to sensor reference point Beam angle Measurement
Type range
1-1/2" threaded 2" threaded 3" threaded
connection connection connection
1.5" horn 139.8 (5.57) 235 (9.3) N/A N/A 19 degrees 10 m (32.8 ft)
2" horn 147.8 (5.88) N/A 266 (10.55) 280 (11.09) 15 degrees 20 m (65.6 ft)
3" horn 174.8 (6.94) N/A 299 (11.85) 313 (12.39) 10 degrees 20 m (65.6 ft)
4" horn 194.8 (7.73) N/A 354 (14) 368 (14.55) 8 degrees 20 m (65.6 ft)

SITRANS LR250 Threaded Horn Antenna with Extension, dimensions in mm (inch)

Siemens FI 01 · 2015 4/221


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

Flanged Horn
50 ½" NPT cable entry
(2.0) (or alternatively,
M20 cable gland)

Threaded cover

167

4
(6.6)

154 90
(6.1) (3.5)
Enclosure/
electronics

Name-plate
227 (8.94)

Retaining collar
190
Flange
(7.48)

horn

135.3 168.3 223.3


5.32 6.62 8.79 Process
connection tag

50 (2) nominal

80 (3) nominal

100 (4) nominal

horn
O.D.

Nominal Horn Horn O.D. Height to sensor reference point Beam angle Measurement
Size Stainless steel range
flange raised or Optional alloy flange
flat-faced
50 (2) 47.8 (1.88) 135.3 (5.32) 138.3 (5.44) 19 degrees 10 m (32.8 ft)
80 (3) 74.8 (2.94) 168.3 (6.62) 171.3 (6.74) 15 degrees 20 m (65.6 ft)
100 (4) 94.8 (3.73) 223.3 (8.79) 226.3 (8.90) 10 degrees 20 m (65.6 ft)

SITRANS LR250 Flanged Horn Antenna, dimensions in mm (inch)

4/222 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

Flanged Horn with Extension


½" NPT cable entry
50
(or alternatively,
(2.0)
M20 cable gland)

Threaded cover

167
(6.6)
154
(6.1)
enclosure/
90
(3.5) 4
electronics

name-plate
227 (8.94)

retaining collar 190


flange (7.48)

process
connection tag

235.3
(9.32) 268.3
(10.62)
horn 323.3
(12.79)

50 (2) nominal

80 (3) nominal

100 (4) nominal

Horn O.D.

Nominal Horn Horn O.D. Height to sensor reference point Beam angle Measurement
Size Stainless steel range
flange raised or Optional alloy flange
flat-faced
50 (2) 47.8 (1.88) 235.3 (9.32) 238.3 (9.44) 19 degrees 10 m (32.8 ft)
80 (3) 74.8 (2.94) 268.3 (10.62) 271.3 (10.74) 15 degrees 20 m (65.6 ft)
100 (4) 94.8 (3.73) 323.3 (12.79) 326.3 (12.90) 10 degrees 20 m (65.6 ft)

SITRANS LR250 Flanged Horn Antenna with Extension, dimensions in mm (inch)

Siemens FI 01 · 2015 4/223


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Horn Antenna

■ Schematics
Connect the wires to the Hand Programmer
terminals as shown: the
polarity is identified on the
terminal block.

4 Shield for HART,


PROFIBUS PA , and Part number:
Gland 7ML1930-1BK
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR250 connections

4/224 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Specials

■ Selection and ordering data


SITRANS LR250 Specials SITRANS LR250 Specials
Article No. Article No.
SITRANS LR250 horn version enclosures SITRANS LR250 horn version enclosures
(PROFIBUS PA models) (< 3.6 mA start-up HART)

LR250 horn version enclosure with board stack, A5E01156836 SITRANS LR250 horn version enclosure with A5E02956317
NPT cable inlet, approval option A, board stack, M20 cable inlet, approval option A,
with PROFIBUS PA communication, with HART communication start-up at < 3.6 mA,
no process connection no process connection
LR250 horn version enclosure with board stack, A5E01156838 SITRANS LR250 horn version enclosure with A5E02956319
M20 cable inlet, approval option A, board stack, M20 cable inlet, approval option C,

4
with PROFIBUS PA communication, with HART communication start-up at < 3.6 mA,
no process connection no process connection
LR250 horn version enclosure with board stack, A5E01156839 SITRANS LR250 horn version enclosure with A5E02956320
NPT cable inlet, approval option B, board stack, M20 cable inlet, approval option E,
with PROFIBUS PA communication, with HART communication start-up at < 3.6 mA,
no process connection no process connection
LR250 horn version enclosure with board stack, A5E01156841
M20 cable inlet, approval option B, SITRANS LR250 horn version enclosure with A5E02956322
with PROFIBUS PA communication, board stack, M20 cable inlet, approval option F,
no process connection with HART communication start-up at < 3.6 mA,
no process connection
LR250 horn version enclosure with board stack, A5E01156843
NPT cable inlet, approval option C, SITRANS LR250 horn version enclosure with A5E02956323
with PROFIBUS PA communication, board stack, M20 cable inlet, approval option G,
no process connection with HART communication start-up at < 3.6 mA,
no process connection
LR250 horn version enclosure with board stack, A5E01156844
M20 cable inlet, approval option C, LR250 horn version enclosure with board stack, A5E03441096
with PROFIBUS PA communication, NPT cable inlet, approval option A, with HART
no process connection communication start-up at < 3.6 mA, no process
connection
LR250 horn version enclosure with board stack, A5E01156846
M20 cable inlet, approval option C, LR250 horn version enclosure with board stack, A5E03441097
with PROFIBUS PA communication, NPT cable inlet, approval option B, with HART
no process connection communication start-up at < 3.6 mA, no process
connection
LR250 horn version enclosure with board stack, A5E01156848
M20 cable inlet, approval option D, LR250 horn version enclosure with board stack, A5E03441098
with PROFIBUS PA communication, NPT cable inlet, approval option D, with HART
no process connection communication start-up at < 3.6 mA, no process
LR250 enclosure with board stack, NPT cable A5E03769538 connection
inlet, approval option B, LR250 horn version enclosure with board stack, A5E03441099
with FOUNDATION FIELDBUS communication, NPT cable inlet, approval option H, with HART
no process connection communication start-up at < 3.6 mA, no process
LR250 enclosure with board stack, NPT cable A5E03769539 connection
inlet, approval option D, SITRANS LR250 horn antenna and
with FOUNDATION FIELDBUS communication, extension kits
no process connection
LR250 enclosure with board stack, M20 cable A5E03769543
inlet, approval option E,
with FOUNDATION FIELDBUS communication,
no process connection
SITRANS LR250 horn version enclosures
(FOUNDATION Fieldbus models) 38 mm (1.5 inch) horn antenna kit, A5E01151539
1.5" Process Connections only
100 mm (4 inch) horn antenna extension kit, A5E01151553
1.5" Process Connections only
50 mm (2 inch) stainless steel 316L horn antenna kit A5E01151569
75 mm (3 inch) stainless steel 316L horn antenna kit A5E01151571
LR250 horn version enclosure with board stack, A5E02654608
M20 cable inlet, approval option C, 100 mm (4 inch) stainless steel 316L horn antenna kit A5E01151573
with FOUNDATION Fieldbus communication,
no process connection 100 mm (4 inch) horn antenna extension kit, A5E01151577
50 mm (2 inch), 75 mm (3 inch) and 100 mm
LR250 horn version enclosure with board stack, A5E02653792 (4 inch) process connection
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication, 50 mm (2 inch) horn antenna kit, Hastelloy C-22 A5E01151584
no process connection 75 mm (3 inch) horn antenna kit, Hastelloy C-22 A5E01151585
LR250 horn version enclosure with board stack, A5E02653793 100 mm (4 inch) horn antenna kit, Hastelloy C-22 A5E01151587
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication, 5 Dupont 1Gr Polyback, PTFE grease kit A5E01151626
no process connection
LR250 lid with O-ring A5E02465410
LR250 horn version enclosure with board stack, A5E02654606
NPT cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection

Siemens FI 01 · 2015 4/225


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna

■ Overview ■ Benefits
• Fully insulated PVDF antenna design for use in chemical and
sanitary environments where aggressive and corrosive
materials are used
• Cost effective replacement for transmitters made of exotic
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 50 mm (2 inch) process
connection/antenna allow for easy mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna

4 • Communication using HART or PROFIBUS PA,


or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
SITRANS LR250 with threaded PVDF antenna is a 2-wire, measurement reliability and Auto False-Echo Suppression of
25 GHz pulse radar level transmitter for continuous monitoring of fixed obstructions
liquids and slurries in storage and process vessels including • Programming using infrared Intrinsically Safe handheld
corrosives or aggressive materials, to a range of 10 m (32.8 ft) or programmer or over a network using SIMATIC PDM,
20 m (66 ft) when used in a stilling pipe. Emerson AMS, or Field Device Tools, such as PACTware or
Fieldcare via SITRANS DTM.
• Suitable for use in Safety Related Systems in accordance with
IEC 61508/61511 (SIL-2)
• 3 mm (0.118 inch) accuracy in accordance with IEC 60770-1

■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 10 m (32 ft) on materials with dk > 3 or 20 m
(66 ft) when used in a stilling pipe with dk  1.6.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, temperatures to 80 °C
(176 °F), corrosive and aggressive materials and applications
requiring functional safety

4/226 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna

■ Configuration
Installation

Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the antenna. 19°
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.

4
Mounting unit on bypass Mounting unit on
stilling well

Orient front or back of Orient front or back of device


device toward vent. toward stillpipe slots.

Mounting unit on vessel Mounting on a nozzle


min. 10 (0.4)

”•UG\WGOYP

SITRANS LR250 PVDF antenna installation, dimensions in mm (inch)

Siemens FI 01 · 2015 4/227


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna

■ Technical specifications
Mode of operation Power supply
Measuring principle Radar level measurement 4 ... 20 mA/HART Nominal 24 V DC (max. 30 V DC)
with max. 550 
Frequency K-band (25.0 GHz)
PROFIBUS PA • 15 mA
Minimum measuring range 50 mm (2 inch) from end of antenna • per IEC 61158-2
Maximum measuring range 10 m (32.8 ft) or 20 m (66 ft) when FOUNDATION Fieldbus • 20.0 mA
used in a stilling pipe with dk  1.6 • per IEC 61158-2
Output Certificates and approvals
HART Version 5.1
• Analog output 4 ... 20 mA General CSAUS/C, CE, FM, NE 21, RCM
• Accuracy ± 0.02 mA Radio FCC, Industry Canada and
• Fail-safe • Programmable as high low or Europe ETSI EN 302-372, RCM
hold (loss of echo) Hazardous
• NE 43 programmable
• Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T4 Ga/Gb,
PROFIBUS PA Profile 3.1 Ex ia ta IIIC T100 °C Da
• Function blocks 2 Analog Input (AI)

4
• Increased Safety (Brazil) INMETRO Ex e ia mb IIC T4 Ga/Gb,
FOUNDATION Fieldbus H1 Ex ia ta IIIC T100 °C Da
• Functionality Basic or LAS • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga, Ex ia ta
• Version ITK 5.2.0 IIIC T100 °C Da
• Function blocks 2 Analog Input (AI) • Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Performance (according to Groups E, F, G; Class III T4
reference conditions IEC60770-1)
• Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1,
Maximum measured error • > 500 mm from sensor reference Groups A, B, C, D; Class II, Div. 1,
point: 3 mm (0.118 inch) Groups E, F, G; Class III T4
• < 500 mm from sensor reference
• Non-incendive (Canada/USA) CSA/FM Class I, Div. 2,
point: 25 mm (1 inch)
Groups A, B, C, D T5
Influence of ambient temperature < 0.003 %/K
• Flame Proof/Increased Safety Ex d ia mb IIC T4 Ga/Gb, Ex e ia mb
Rated operating conditions (China) IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP
A20 TA90 ºC
Installation conditions
• Intrinsically Safe (China) Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67
Location Indoor/outdoor DIP A20 TA90 ºC
• Non-sparking (China) NEPSI Ex nA IIC T4 Gc
Ambient conditions (enclosure)
• Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 Ga
Ambient temperature -40 ... +80 °C (-40 ... +176 °F) ATEX II 1D Ex ia ta IIC T100 °C Da
Installation category I • Non-sparking/Energy Limited ATEX II 3G Ex nA IIC T4 Gc
(Europe)
Pollution degree 4 • Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D,
Medium conditions Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
Dielectric constant r  3 (1.6 in stillpipe) • Increased Safety IECEx/ATEX II 1/2 GD, 1D, 2D,
Process temperature -40 ... +80 °C (-40 ... +176 °F) at (International/Europe) Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
process connection (Is suitable for T100 °C Da
CIP at 120 °C for 1/2 hr max.) • Intrinsically Safe (International) IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
IECEX/ATEX II 1D Ex ia ta IIC T100 °C
Process pressure Up to 5 bar g (72 psi g) temperature Da
dependent. • Explosion Proof (Russia) GOST-R Ex d
See Pressure/Temperature curves for
more information • Increased Safety (Russia) GOST-R Ex e
• Intrinsically Safe (Russia) GOST-R Ex ia
Design
• Marine • Lloyd's Register of Shipping
Enclosure • ABS Type Approval
• Material Aluminum, polyester powder-coated • Bureau Veritas
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT Functional Safety SIL-2 suitable in accordance with
Degree of protection Type 4X/NEMA 4X, Type 6/ IEC 61508/61511
NEMA 6, IP67, IP68
Weight approximately 3.3 kg (7.27 lb) Programming
Display (local) Graphic local user interface Intrinsically Safe Siemens handheld Infrared receiver
including quick start wizard and programmer
echo profile display • Approvals for handheld IS model:
Antenna programmer ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135°C Ta = -20 ... +50 °C
• Material PVDF (Polyvinylidene fluoride) CSA/FM Class I, II, III, Div. 1,
• Dimensions (nominal sizes) 2 inch (48 mm) Groups A, B, C, D, E, F, G, T6
Process connections Ta = +50 °C
IECEx SIR 09.0073
Process connection 2" NPT [(Taper), ASME B1.20.1]
2" [(BSPT), EN 10226] Handheld communicator HART communicator 375/475
2" [(BSPP), EN ISO 228-1] PC • SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or
Fieldcare)
Display (local) Graphic local user interface including
quick start wizard and echo profile
displays

4/228 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR250 threaded PVDF antenna 7ML5431- Further designs
2-wire, 25 GHz pulse radar level transmitter for 77 7 7 0 - 77 77 Please add "-Z" to Article No. and specify Order
continuous monitoring of liquids and slurries in code(s).
storage and process vessels including corrosives
or aggressive materials, to a range of 10 m (32.8 ft) Plug M12 with mating Connector1)2)3) ¢ A50
or 20m (66ft) when used in a stilling pipe. Plug 7/8" with mating Connector2)3)4) ¢ A55
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Process Connection and Antenna Material (max. 27 characters); specify in plain text
Threaded PVDF antenna ¢ 4
Manufacturer's test certificate: M to DIN 55350, ¢ C11
Process Connection Type Part 18 and to ISO 9000
Threaded connections PVDF
2" NPT (ASME B1.20.1) (tapered thread) ¢ PA Inspection Certificate Type 3.1 per EN 10204 ¢ C12
R 2" [(BSPT), EN 10226-1] (tapered thread) ¢ PB Functional Safety (SIL 2). Device suitable for use ¢ C20
G 2" [(BSPP), EN ISO 228-1] (parallel thread) ¢ PC in accordance with IEC 61508 and IEC 615115)6)
Communication/Output
Namur NE43 compliant, device preset to failsafe ¢ N07
PROFIBUS PA ¢ 1
4
< 3.6 mA5)
4 ... 20 mA, HART, start-up at < 3.6 mA ¢ 2
FOUNDATION Fieldbus ¢ 3 Operating Instructions for HART/mA device Article No.
Enclosure/Cable inlet English A5E32220602
Aluminum, Epoxy painted
2 x ½" NPT ¢ 0 German A5E32376088
2 x M20x1.5 ¢ 1 Note: The Operating Instructions should be orde-
Antenna red as a separate line item on the order.
2 inch(50 mm) threaded PVDF antenna ¢ R Compact Operating Instructions for HART/mA
device
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM¢ A English, French, German, Spanish, Italian, Dutch, A5E33469191
Danish, Finnish, Greek, Portuguese (Portugal),
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢ B Swedish
B, C, D, Class II, Div.1, Groups E ,F, G, Class III T4
FCC, Industry Canada English, Bulgarian, Czech, Estonian, Hungarian, A5E33469171
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4 Ga, ¢ C Slovenian
IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da,
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 oC Da, This device is shipped with the Siemens Milltronics
CE, R&TTE, RCM manual DVD containing the ATEX Compact Opera-
ting Instructions and Operating Instructions library.
Non-incendive: CSA/FM Class I, Div. 2, Groups A, ¢ D
B, C, D T5, FCC, Industry Canada Operating Instructions for PROFIBUS PA device
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE, ¢ E English A5E32221386
R&TTE, RCM
German A5E32376094
Increased Safety: IECEx/ATEX II 1/2 GD,1D, ¢ F
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Note: The Operating Instructions should be orde-
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC red as a separate line item on the order.
T100 oC Da, CE, R&TTE, RCM1) Compact Operating Instructions for
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢ G PROFIBUS PA device
ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC English, French, German, Spanish, Italian, Dutch, A5E33469239
T100 oC Da, CE, R&TTE, RCM1) Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
Explosion proof: CSA/FM Class I, II and III, Div.1, ¢ H
Groups A, B, C, D, E, F, G, FCC, Industry Canada1) English, Bulgarian, Czech, Estonian, Hungarian, A5E33472685
Latvian, Lithuanian, Polish, Romanian, Slovakian,
Non Sparking: NEPSI Ex nA IIC T4 Gc ¢ K Slovenian
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 ¢ L
This device is shipped with the Siemens Milltronics
T90 IP67 DIP A20 TA90 ºC
manual DVD containing the ATEX Compact Opera-
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, ¢ M ting Instructions and Operating Instructions library.
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC1)
¢ We can offer shorter delivery times for configurations designated with the
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢ N Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC1)
Pressure rating
Rating per Pressure/Temperature curves in manual ¢ 2
1) Applicable to Communication option 2 only
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/229


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna
Selection and Ordering data Article No. Selection and Ordering data Article No.
Operating Instructions for Accessories
FOUNDATION Fieldbus device
Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
English A5E32221411
HART modem/USB 7MF4997-1DB
German A5E32376112 (for use with a PC and SIMATIC PDM)
Note: The Operating Instructions should be orde- One metallic cable gland M20x1.5, 7ML1930-1AP
red as a separate line item on the order. rated -40 ... +80 °C (-40 ... +176 °F), HART
Compact Operating Instructions for One metallic cable gland M20x1.5, 7ML1930-1AQ
FOUNDATION Fieldbus device rated -40 ... +80 °C (-40 ... +176 °F),
English, French, German, Spanish, Italian, Dutch, A5E33472700 PROFIBUS PA and FOUNDATION Fieldbus2)
Danish, Finnish, Greek, Portuguese (Portugal), FDA approved FKM o-ring for 2" G (BSPP) process 7ML1830-3AN
Swedish connections -28 ... +80 °C (-28 ... +176 °F)
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472738 SITRANS RD100, loop powered display - 7ML5741-...
Latvian, Lithuanian, Polish, Romanian, Slovakian, see Chapter 7
Slovenian
SITRANS RD200, universal input display with 7ML5740-...
This device is shipped with the Siemens Milltronics Modbus conversion - see Chapter 7
4 manual DVD containing the ATEX Compact Opera-
ting Instructions and Operating Instructions library. SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion -
7ML5744-...

see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1) Available with Enclosure option 1 only
2) To be used with Communication options 1 and 3 only.
Connector has IP67 rating.
3) Available with Approval options A and B. Available with approval option C
for use on intrinsically safe applications only. Not rated for dust Ex.
4) Available with Enclosure option 0 only
5)
Available with communication option 2 only
6)
Available with approval options A ... E only

■ Characteristic curves
Pressure/Temperature Curve
Pressure (bar, gauge)

20 ºC,
5 5 bar

4.5

4
3.5

3
2.5
80 ºC,
2.25 bar
2
1.5
1

0.5

0
-0.5

-1

-60 -40 -20 0 20 40 60 80 100


Temperature (°C)

SITRANS LR250 PVDF antenna pressure/temperature curve

4/230 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF antenna

■ Dimensional drawings
50
(2.0)
1/2" NPT cable entry (or
alternatively, M20 cable gland)

Threaded cover

167

4
154 (6.6)
(6.1) 90
(3.5)

Enclosure/
electronics
184
(7.24) 146
Process
(5.74)
connection tag

Sensor reference
point

121
(4.76) 2" thread

Threaded PVDF
antenna
49.5
(1.94)
antenna O.D.

SITRANS LR250 PVDF antenna, dimensions in mm (inch)

■ Schematics
Connect the wires to the Hand Programmer
terminals as shown: the
polarity is identified on the
terminal block.

Shield for HART,


PROFIBUS PA , and Part number:
Gland 7ML1930-1BK
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR250 connections

Siemens FI 01 · 2015 4/231


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 threaded PVDF Specials

■ Selection and ordering data


SITRANS LR250 threaded PVDF Specials SITRANS LR250 threaded PVDF Specials
Article No. Article No.
SITRANS LR250 threaded PVDF SITRANS LR250 threaded PVDF
antenna version enclosures antenna version enclosures
(PROFIBUS PA models) (< 3.6 mA start-up HART models)
LR250 threaded PVDF antenna version A5E03588171 LR250 enclosure with board stack, A5E03569747
enclosure with board stack, M20 cable inlet, M20 cable inlet, approval option A,
approval option A, with PROFIBUS PA with HART communication start-up
communication, no process connection at < 3.6 mA, no process connection
LR250 threaded PVDF antenna version A5E03588253 LR250 enclosure with board stack, A5E03586807
enclosure with board stack, NPT cable inlet, NPT cable inlet, approval option A,
approval option A, with PROFIBUS PA with HART communication start-up
communication, no process connection at < 3.6 mA, no process connection
LR250 threaded PVDF antenna version A5E03588512 LR250 enclosure with board stack, A5E03586854
enclosure with board stack, NPT cable inlet, NPT cable inlet, approval option B,
4 approval option B, with PROFIBUS PA
communication, no process connection
with HART communication start-up
at < 3.6 mA, no process connection
LR250 threaded PVDF antenna version A5E03589260 LR250 enclosure with board stack, A5E03586887
enclosure with board stack, M20 cable inlet, M20 cable inlet, approval option C,
approval option C, with PROFIBUS PA with HART communication start-up
communication, no process connection at < 3.6 mA, no process connection
LR250 threaded PVDF antenna version A5E03589262 LR250 enclosure with board stack, A5E03586961
enclosure with board stack, NPT cable inlet, NPT cable inlet, approval option D,
approval option D, with PROFIBUS PA with HART communication start-up
communication, no process connection at < 3.6 mA, no process connection
LR250 threaded PVDF antenna version A5E03589264 LR250 enclosure with board stack, A5E03587012
enclosure with board stack, M20 cable inlet, M20 cable inlet, approval option E,
approval option E, with PROFIBUS PA with HART communication start-up
communication, no process connection at < 3.6 mA, no process connection
SITRANS LR250 threaded PVDF LR250 enclosure with board stack, A5E03587132
antenna version enclosures M20 cable inlet, approval option F,
(FOUNDATION Fieldbus models) with HART communication start-up
at < 3.6 mA, no process connection
LR250 enclosure with board stack, A5E03589266
M20 cable inlet, approval option A, LR250 enclosure with board stack, A5E03587223
with FOUNDATION Fieldbus communication, M20 cable inlet, approval option G,
no process connection with HART communication start-up
at < 3.6 mA, no process connection
LR250 enclosure with board stack, A5E03589275
NPT cable inlet, approval option A, LR250 enclosure with board stack, A5E03588125
with FOUNDATION Fieldbus communication, NPT cable inlet, approval option H,
no process connection with HART communication start-up
at < 3.6 mA, no process connection
LR250 enclosure with board stack, A5E03589277
NPT cable inlet, approval option B, SITRANS LR250 threaded PVDF
with FOUNDATION Fieldbus communication, antenna kits
no process connection
Antenna kit 2" NPT threaded PVDF A5E03528941
LR250 enclosure with board stack, A5E03589280
M20 cable inlet, approval option C, Antenna kit 2" R (BSPT) threaded PVDF A5E03528943
with FOUNDATION Fieldbus communication, Antenna kit 2" G (BSPP) threaded PVDF A5E03528947
no process connection
Kit of hardware parts for LR250 threaded PVDF A5E03528948
LR250 enclosure with board stack, A5E03589281 antenna: consists of O-rings, screws,
NPT cable inlet, approval option D, wavewasher and loctite
with FOUNDATION Fieldbus communication,
no process connection
LR250 enclosure with board stack, A5E03589283
M20 cable inlet, approval option E,
with FOUNDATION Fieldbus communication,
no process connection

4/232 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
SITRANS LR250 measures superbly in small vessels and in
■ Overview tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, temperatures to 170 °C
(338 °F), corrosive and aggressive materials and applications
where ease of cleaning is required, such as food or fine
chemicals.

■ Configuration
Installation

Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
4
3"/DN 80/80A
density. or larger
• The peak energy density is
directly in front of and in line 9.6° 2"/DN 50
SITRANS LR250 with flanged encapsulated antenna is a 2-wire, with the antenna. /50A
• There is a signal transmitted 12.8°
25 GHz pulse radar level transmitter for continuous monitoring of
outside of the beam angle;
liquids and slurries in storage and process vessels including therefore false targets may be
corrosives or aggressive materials, to a range of 20 m (66 ft) detected.
(antenna dependent).

■ Benefits
Mounting unit on bypass Mounting unit on
• Fully encapsulated horn antenna design with FDA approved stilling well
TFM 1600 PTFE lens for use in chemical and sanitary environ-
ments where aggressive and corrosive materials are used Orient front or back of Orient front or back of device
• Cost effective replacement for transmitters made of exotic device toward vent. toward stillpipe slots.
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 50 mm (2 inch) process
connection/antenna allow for easy mounting
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna
• Communication using HART, PROFIBUS PA,
or FOUNDATION Fieldbus
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM, Emerson
AMS, or Field Device Tools, such as PACTware or Fieldcare via
SITRANS DTM
• Functional Safety (SIL 2). Device suitable for use in accor- Mounting unit on vessel Mounting on a nozzle
dance with IEC 61508 and IEC 61511
Max. 500 (20)

■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Start-up is easy using Quick Start Wizard with a few param-
eters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250's unique design allows safe and simple pro- t•UG\WGOYP
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument's lid. SITRANS LR250 flanged encapsulated antenna installation,
dimensions in mm (inch)

Siemens FI 01 · 2015 4/233


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

■ Technical specifications
Mode of operation Process connections
Measuring principle Radar level measurement Flanged connection Raised Face
Frequency K-band (25.0 GHz) • 2, 3, 4, 6" Class 150 ASME B16.5
• 50A, 80A, 100A, 150A 10K JIS B
Minimum measuring range 50 mm (2 inch) from end of antenna 2220
Maximum measuring range 20 m (66 ft) • DN 50, DN 80, DN 100 &
DN 150 PN 10/16 EN 1092-1
Output type B1
HART Version 5.1
Power supply
• Analog output 4 ... 20 mA
• Accuracy ± 0.02 mA 4 ... 20 mA/HART Nominal 24 V DC (max. 30 V DC)
with max. 550 
• Fail-safe • Programmable as high low or hold
(loss of echo) PROFIBUS PA • 15 mA
• NE 43 programmable • Per IEC 61158-2
PROFIBUS PA Profile 3.01
FOUNDATION Fieldbus • 20.0 mA
• Function blocks 2 Analog Input (AI) • Per IEC 61158-2
FOUNDATION Fieldbus H1
4 • Functionality
• Version
Basic or LAS
ITK 5.2.0
Certificates and approvals
General CSAUS/C, CE, FM, NE 21, RCM
• Function blocks 2 Analog Input (AI) Radio FCC, Industry Canada and
Performance (according to refer- Europe ETSI EN 302-372, RCM
ence conditions IEC60770-1) Hazardous
Maximum measured error • > 500 mm from sensor reference • Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T4 Ga/Gb,
point: 3 mm (0.118 inch) Ex ia ta IIIC T100 °C Da
• < 500 mm from sensor reference • Increased Safety (Brazil) INMETRO Ex e ia mb IIC T4 Ga/Gb,
point: 25 mm (1 inch) Ex ia ta IIIC T100 °C Da
Influence of ambient temperature < 0.003 %/K • Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga, Ex ia ta
IIIC T100 °C Da
Rated operating conditions • Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1,
Installation conditions Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
Location Indoor/outdoor • Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1,
Ambient conditions (enclosure) Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III T4
Ambient temperature -40 ... +80 °C (-40 ... +176 °F) • Non-incendive (Canada/USA) CSA/FM Class I, Div. 2,
Installation category I Groups A, B, C, D T5
• Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T4 Ga/Gb,
Pollution degree 4 (China) Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
Medium conditions T90 IP67 DIP A20 TA90 ºC
• Intrinsically Safe (China) NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
Dielectric constant r  1.6 (antenna dependent) IP67 DIP A20 TA90 ºC
Process temperature -40 ... +170 °C (-40 ... +338 °F) at • Non-sparking/Energy Limited NEPSI Ex nA IIC T4 Gc
process connection (China)
• Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 Ga
Process pressure See Pressure/Temperature curves for
more information (page 4/237) ATEX II 1D Ex ia ta IIIC T100 °C Da
• Non-sparking/Energy Limited ATEX II 3G Ex nA IIC T4 Gc
Design (Europe)
Enclosure • Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D
• Material Aluminum, polyester powder-coated Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT T100 °C Da
• Increased Safety IECEx/ATEX II 1/2 GD, 1D, 2D,
Degree of protection Type 4X/NEMA 4X, Type 6/NEMA 6, (-International/Europe) Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
IP67, IP68 T100 °C Da
Weight (dependent on process con- • Approx. 7 kg (15.43 lb) for • Intrinsically Safe (International) IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
nection) 2" Class 150 ASME B16.5 raised IECEx/ATEX II 1D Ex ia ta IIIC
face flange (smallest size) T100 °C Da
• Approx. 17.7 kg (39.02 lb) for • Explosion Proof (Russia) GOST-R Ex d
6" Class 150 ASME B16.5 raised • Increased Safety (Russia) GOST-R Ex e
face flange (largest size) • Intrinsically Safe (Russia) GOST-R Ex ia
Display (local) Graphic local user interface including • Marine • Lloyd’s Register of Shipping
quick start wizard and echo profile • ABS Type Approval
display • Bureau Veritas
Antenna • Functional Safety SIL-2 suitable in accordance with
IEC 61508/61511
• Material Stainless Steel 316L (1.4435 or
1.4404) and TFM 1600 PTFE Lens
(lens is the only wetted part)
• Dimensions (nominal sizes) 48 mm (2 inch), 80 mm (3 inch),
100 mm (4 inch), 150 mm (6 inch)

4/234 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Programming Selection and Ordering data Article No.
Intrinsically Safe Siemens handheld Infrared receiver SITRANS LR250 flanged encapsulated antenna 7ML5432-
programmer 2-wire, 25 GHz pulse radar level transmitter for 7 7 7 7 0 - 77 7 7
• Approvals for handheld- IS model: ATEX II 1 GD Ex ia IIC T4 continuous monitoring of liquids and slurries in
programmer Ga Ex ia D 20 T135 °C storage and process vessels including high
Ta = -20 ... +50 °C temperature and pressure, to a range of 20 m (66 ft)
CSA/FM Class I, II, III, Div. 1, (antenna dependant). Ideal for corrosive, aggressive
Groups A, B, C, D, E, F, G, T6 and low dielectric media.
Ta = 50 °C IECEx SIR 09.0073 Click on the Article No. for the online configura-
Handheld communicator HART communicator 375/475 tion in the PIA Life Cycle Portal.
PC • SIMATIC PDM Process Connection Material
• Emerson AMS Stainless steel 1.4404/1.4435 0
• SITRANS DTM (for connection into Process Connection Type
FDT, such as PACTware or Flanged Process Connection Types
Fieldcare) (stainless steel 1.4404/1.4435)
Display (local) Graphic local user interface including 2" Class 150 ASME B16.5 raised face1) ¢ BF
quick start wizard and echo profile 3" Class 150 ASME B16.5 raised face ¢ BG
displays 4" Class 150 ASME B16.5 raised face ¢ BH
6" Class 150 ASME B16.5 raised face BJ
50A 10K JIS B 2220 raised face
80A 10K JIS B 2220 raised face
1)
FD
FE 4
100A 10K JIS B 2220 raised face FF
150A 10K JIS B 2220 raised face FG
1)
DN 50 PN 10/16 EN 1092-1 type B1 raised face ¢ GA
DN 80 PN 10/16 EN 1092-1 type B1 raised face ¢ GB
DN 100 PN 10/16 EN 1092-1 type B1 raised face ¢ GC
DN 150 PN 10/16 EN 1092-1 type B1 raised face GD
Communication/Output
PROFIBUS PA ¢ 1
4 ... 20 mA, HART, start-up at < 3.6 mA ¢ 2
FOUNDATION Fieldbus ¢ 3
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT ¢ 0
2 x M20x1.5 ¢ 1
Antenna lens material
TFM 1600 PTFE Flush Lens ¢ A
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, ¢ A
RCM
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, ¢ B
B, C, D, Class II, Div.1, Groups E, F, G, Class III T4
FCC, Industry Canada
Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T4 Ga, ¢ C
IECEx/ATEX II 1D Ex ia ta IIIC T100 °C Da, INMETRO
Ex ia IIC T4 Ga, Ex ia ta IIIC T100 oC Da, CE, R&TTE,
RCM
Non-incendive: CSA/FM Class I, Div. 2, Groups A, B, ¢ D
C, D T5, FCC, Industry Canada
Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE, ¢ E
R&TTE, RCM
Increased Safety: IECEx/ATEX II 1/2 GD,1D, ¢ F
2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
T100 oC Da, CE, R&TTE, RCM2)
Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ia ¢ G
IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da, INMETRO Ex
d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC T100 oC Da, CE,
R&TTE, RCM2)
Explosion proof: CSA/FM Class I, II and III, Div.1, ¢ H
Groups A, B, C, D, E, F, G, FCC, Industry Canada2)
Non Sparking: NEPSI Ex nA IIC T4 Gc ¢ K
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, ¢ L
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, ¢ M
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC2)
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢ N
Ex iaD 20 T90 IP67 DIP A20 TA90 ºC2)
Pressure rating
Rating per Pressure/Temperature curves in ¢ 0
instruction manual
1)
Maximum range 10 m (32.8 ft), dk > 3 [20 m (66 ft)] and dk>1.6 when
mounted in stillpipe]
2)
Applicable with communication option 2 only

¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

Siemens FI 01 · 2015 4/235


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Operating Instructions for
FOUNDATION Fieldbus device
Please add "-Z" to Article No. and specify Order
code(s). English A5E32221411
Plug M12 with mating Connector1)2)3) ¢ A50 German A5E32376112
Plug 7/8" with mating Connector2)3)4) ¢ A55 Note: The Operating Instructions should be orde-
red as a separate line item on the order.
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification Compact Operating Instructions for
(max. 27 characters); specify in plain text FOUNDATION Fieldbus device
Manufacturer's test certificate: M to DIN 55350, ¢ C11 English, French, German, Spanish, Italian, Dutch, A5E33472700
Part 18 and to ISO 9000 Danish, Finnish, Greek, Portuguese (Portugal),
Swedish
Inspection Certificate Type 3.1 per EN 10204 ¢ C12
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472738
Functional Safety (SIL 2). Device suitable for use in ¢ C20 Latvian, Lithuanian, Polish, Romanian, Slovakian,
accordance with IEC 61508 and IEC 615115)6) Slovenian
Namur NE43 compliant, device preset to failsafe ¢ N07
< 3.6 mA5) This device is shipped with the Siemens Milltronics

4 Operating Instructions for HART/mA device Article No.


manual DVD containing the ATEX Compact Opera-
ting Instructions and Operating Instructions library.
English A5E32220602 Accessories
German A5E32376088 Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
Note: The Operating Instructions should be orde- HART modem/USB 7MF4997-1DB
red as a separate line item on the order. (for use with a PC and SIMATIC PDM)
Compact Operating Instructions for HART/mA One metallic cable gland M20x1.5, 7ML1930-1AP
device rated -40 ... +80 °C (-40 ... +176 °F),
English, French, German, Spanish, Italian, Dutch, A5E33469191 HART (2 are required)6)
Danish, Finnish, Greek, Portuguese (Portugal), One metallic cable gland M20x1.5, 7ML1930-1AQ
Swedish rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
English, Bulgarian, Czech, Estonian, Hungarian, A5E33469171 and FOUNDATION Fieldbus (2 are required)2)
Latvian, Lithuanian, Polish, Romanian, Slovakian, SITRANS RD100, loop powered display - 7ML5741-...
Slovenian see Chapter 7
This device is shipped with the Siemens Milltronics SITRANS RD200, universal input display with 7ML5740-...
manual DVD containing the ATEX Compact Opera- Modbus conversion - see Chapter 7
ting Instructions and Operating Instructions library.
SITRANS RD300, dual line display with totalizer 7ML5744-...
Operating Instructions for PROFIBUS PA device and linearization curve and Modbus conversion -
English A5E32221386 see Chapter 7

German A5E32376094 SITRANS RD500 web, universal remote monitoring 7ML5750-...


solution for instrumentation - see Chapter 7
Note: The Operating Instructions should be orde-
red as a separate line item on the order. For applicable back up point level switch -
see point level measurement section
Compact Operating Instructions for
PROFIBUS PA device 1)
Available with enclosure option 1 only
2)
English, French, German, Spanish, Italian, Dutch, A5E33469239 Available with communication options 1 and 3 only
Danish, Finnish, Greek, Portuguese (Portugal), 3)
Available with approval options A, B, C, and L only
Swedish 4)
Available with enclosure option 0 only
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472685 5)
Applicable with communication option 2 only
Latvian, Lithuanian, Polish, Romanian, Slovakian, 6)
Available with approval options A, B, C, D, E, K, and L only
Slovenian
This device is shipped with the Siemens Milltronics ¢ We can offer shorter delivery times for configurations designated with the
manual DVD containing the ATEX Compact Opera- Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
ting Instructions and Operating Instructions library.

4/236 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

■ Characteristic curves
Pressure/ temperature curve
LR250 Flanged Encapsulated Antenna
ASME flanged process connections
(7ML5432)

Permitted operating pressures P

30 bar (435 psi)


4
2, 3, and 4" NPS
20 bar (290 psi)
6" NPS

ASME 150 lb
10 bar (145 psi)

Atmospheric -40 °F 14 °F 100 °F 200 °F 300 °F 400 °F


Pressure
(-40 °C) (-10 °C) (38 °C) (93 °C) (149 °C) (204 °C)
T
-1 bar (-14.5 psi)
-50 °C RT 50 °C 100 °C 150 °C 200 °C
(-58 °F) 0 °C (122 °F) (212 °F) (302 °F) (392 °F)
(32 °F)
170 °C
-29 °C
Permitted operating temperatures (338 °F)
(-20 °F)

SITRANS LR250 flanged encapsulated antenna pressure/temperature curve

Pressure/ temperature curve


LR250 Flanged Encapsulated Antenna
EN 1092-1 flanged process connections
(7ML5432)

Permitted operating pressures P

30 bar (435 psi) DN 150

DN 100

20 bar (290 psi) DN 50, DN 80

PN 16
10 bar (145 psi)

Atmospheric -40 °F 14 °F 100 °F 200 °F 300 °F 400 °F


Pressure
(-40 °C) (-10 °C) (38 °C) (93 °C) (149 °C) (204 °C)
T
-1 bar (-14.5 psi)
-50 °C RT 50 °C 100 °C 150 °C 200 °C
(-58 °F) 0 °C (122 °F) (212 °F) (302 °F) (392 °F)
(32 °F) 170 °C
-29 °C
(-20 °F) Permitted operating temperatures (338 °F)

SITRANS LR250 flanged encapsulated antenna pressure/temperature curve

Siemens FI 01 · 2015 4/237


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

Pressure/ temperature curve


LR250 Flanged Encapsulated Antenna
JIS B 2220 flanged process connections
(7ML5432)

Permitted operating pressures 3

EDU SVL $

$

EDU SVL $$

.
4 Atmospheric
EDU SVL

Pressure ഘ ഘ ഘ ഘ ഘ ഘ


ഒ ഒ ഒ ഒ ഒ ഒ
EDU SVL 7
ഒ 57 ഒ ഒ ഒ ഒ
ഘ ഒ ഘ ഘ ഘ ഘ
ഘ
ഒ ഒ
ഒ ഘ ഘ
ഘ

Permitted operating temperatures

SITRANS LR250 flanged encapsulated antenna pressure/temperature curve

4/238 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

■ Dimensional drawings
Flanged Encapsulated Antenna 2"/DN 50/50A
½" NPT cable entry
50 (or alternatively,
(2.0) M20 cable gland)

Threaded cover

167
(6.6)
153
(6.0) 90
3.5

Enclosure

"B"
Retaining "D"
collar
"A"
"C"

Flange

Sensor
ref.
point

"E"

Flange Flange Flange Antenna Height to Beam Measurement


Size Class O.D.
see LR250_E_Installation.cdr
aperture Sensor angle
for dim. values.
Range
Dimension
A
Dimension Dimension
B C
Dimension
D
size reference point
dimension E1)
2" 150 lb 152 (5.98)
DN 50 PN 10/16 165 (6.50) 50 11 12.8° 10 m 263 178 223 274
(1.97) (0.43) (32.8 ft) (10.35) (7) (8.78) (10.79)
50A 10K 155 (6.10)

1)
Height from tip of lens to sensor reference point as shown.

SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/239


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

Flanged Encapsulated Antenna 3"/DN 50/80A or greater

50 ½" NPT cable entry


(2.0) (or alternatively,
M20 cable gland)

Threaded cover

167

4 153
(6.0)
(6.6)
90
3.5

Enclosure

"B"
Retaining
collar "D"

"A"
"C"

Flange
Sensor
ref.
point

"E"
Flange Flange Flange Antenna Height to Beam Measurement Dimension
Size Class O.D.
see LR250_E_Installation.cdr for dim. values.
aperture Sensor angle Range A
Dimension Dimension
B C
Dimension
D
size reference point
dimension E1)
3" 150 lb 190 (7.48)
DN 80 PN 10/16 200 (7.87) 75 15 9.6° 20 m 328 178 288 343
(2.95) (0.59) (65.6 ft) (12.91) (7) (11.34) (13.54)
80A 10K 185 (7.28)
4" 150 lb 230 (9.06)
DN 100 PN 10/16 220 (8.66) 75 13 9.6° 20 m 328 178 288 343
(2.95) (0.51) (65.6 ft) (12.91) (7) (11.34) (13.50)
100A 10K 210 (8.27)
6" 150 lb 280 (11.02)
DN 150 PN 10/16 285 (11.25) 75 15 9.6° 20 m 333 178 293 348
(2.95) (0.59) (65.6 ft) (13.11) (7) (11.54) (13.70)
150A 10K 280 (11.02)
1)
Height from tip of lens to sensor reference point as shown.

SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch)

4/240 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Antenna

■ Schematics
Connect the wires to the Hand Programmer
terminals as shown: the
polarity is identified on the
terminal block.

Shield for HART, 4


PROFIBUS PA , and Part number:
Gland 7ML1930-1BK
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR250 connections

Siemens FI 01 · 2015 4/241


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Flanged Encapsulated Specials

■ Selection and ordering data


SITRANS LR250 flanged encapsulated Specials SITRANS LR250 flanged encapsulated Specials
Article No. Article No.
SITRANS LR250 flanged encapsulated antenna LR250 flanged encapsulated antenna version A5E32462867
version enclosures (7ML5432) enclosure with board stack,
(PROFIBUS PA models) NPT cable inlet, approval option B,
LR250 flanged encapsulated antenna version with HART communication start-up
A5E32462853 at < 3.6 mA, no process connection
(7ML5432) enclosure with board stack, M20 cable
inlet, approval option A, with PROFIBUS PA LR250 flanged encapsulated antenna version A5E32462868
communication, no process connection (7ML5432) enclosure with board stack,
LR250 flanged encapsulated antenna version M20 cable inlet, approval option C,
A5E32462854 with HART communication start-up
(7ML5432) enclosure with board stack, NPT cable
inlet, approval option A, with PROFIBUS PA at < 3.6 mA, no process connection
communication, no process connection LR250 flanged encapsulated antenna version A5E32462869
LR250 flanged encapsulated antenna version (7ML5432) enclosure with board stack,
A5E32462855 NPT cable inlet, approval option D,
(7ML5432) enclosure with board stack, NPT cable
inlet, approval option B, with PROFIBUS PA with HART communication start-up

4 communication, no process connection


LR250 flanged encapsulated antenna version A5E32462856
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version A5E32462830
(7ML5432) enclosure with board stack, M20 cable (7ML5432) enclosure with board stack,
inlet, approval option C, with PROFIBUS PA M20 cable inlet, approval option E,
communication, no process connection with HART communication start-up
LR250 flanged encapsulated antenna version at < 3.6 mA, no process connection
A5E32462857 LR250 flanged encapsulated antenna version
(7ML5432) enclosure with board stack, NPT cable A5E32462831
inlet, approval option D, with PROFIBUS PA (7ML5432) enclosure with board stack,
communication, no process connection M20 cable inlet, approval option F,
LR250 flanged encapsulated antenna version with HART communication start-up
A5E32462858 at < 3.6 mA, no process connection
(7ML5432) enclosure with board stack, M20 cable
inlet, approval option E, with PROFIBUS PA LR250 flanged encapsulated antenna version A5E32462832
communication, no process connection (7ML5432) enclosure with board stack,
M20 cable inlet, approval option G,
SITRANS LR250 flanged encapsulated with HART communication start-up
antenna version enclosures at < 3.6 mA, no process connection
(FOUNDATION Fieldbus models) LR250 flanged encapsulated antenna version
LR250 flanged encapsulated antenna version A5E32462833
A5E32462859 (7ML5432) enclosure with board stack,
(7ML5432) enclosure with board stack, NPT cable inlet, approval option H,
M20 cable inlet, approval option A, with HART communication start-up
with FOUNDATION Fieldbus communication, at < 3.6 mA, no process connection
no process connection
LR250 flanged encapsulated antenna version SITRANS LR250 flanged encapsulated
A5E32462860 antenna lens kits
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option A, Replacement TFM 1600 Lens and Spring Washer A5E32462817
with FOUNDATION Fieldbus communication, Kit for 2" Class 150 ASME B16.5 raised face
no process connection Replacement TFM 1600 Lens and Spring Washer A5E32462819
LR250 flanged encapsulated antenna version Kit for 3" Class 150 ASME B16.5 raised face
A5E32462861
(7ML5432) enclosure with board stack, Replacement TFM 1600 Lens and Spring Washer A5E32462820
NPT cable inlet, approval option B, Kit for 4" Class 150 ASME B16.5 raised face
with FOUNDATION Fieldbus communication, Replacement TFM 1600 Lens and Spring Washer
no process connection A5E32462821
Kit for 6" Class 150 ASME B16.5 raised face
LR250 flanged encapsulated antenna version A5E32462862 Replacement TFM 1600 Lens and Spring Washer
(7ML5432) enclosure with board stack, A5E32462822
Kit for 50A 10K JIS B 2220 raised face
M20 cable inlet, approval option C, Replacement TFM 1600 Lens and Spring Washer
with FOUNDATION Fieldbus communication, A5E32462823
Kit for 80A 10K JIS B 2220 raised face
no process connection
Replacement TFM 1600 Lens and Spring Washer A5E32462824
LR250 flanged encapsulated antenna version A5E32462863 Kit for 100A 10K JIS B 2220 raised face
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option D, Replacement TFM 1600 Lens and Spring Washer A5E32462825
with FOUNDATION Fieldbus communication, Kit for 150A 10K JIS B 2220 raised face
no process connection Replacement TFM 1600 Lens and Spring Washer A5E32462826
LR250 flanged encapsulated antenna version Kit for DN 50 PN 10/16 EN 1092-1 type B1 raised
A5E32462864 face
(7ML5432) enclosure with board stack,
M20 cable inlet, approval option E, Replacement TFM 1600 Lens and Spring Washer A5E32462827
with FOUNDATION Fieldbus communication, Kit for DN 80 PN 10/16 EN 1092-1 type B1 raised
no process connection face
Replacement TFM 1600 Lens and Spring Washer A5E32462828
SITRANS LR250 flanged encapsulated Kit for DN 100 PN 10/16 EN 1092-1 type B1 raised
antenna version enclosures face
(< 3.6 mA start-up HART models)
Replacement TFM 1600 Lens and Spring Washer A5E32462829
LR250 flanged encapsulated antenna version A5E32462865 Kit for DN 150 PN 10/16 EN 1092-1 type B1 raised
(7ML5432) enclosure with board stack, face
M20 cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection
LR250 flanged encapsulated antenna version A5E32462866
(7ML5432) enclosure with board stack,
NPT cable inlet, approval option A,
with HART communication start-up
at < 3.6 mA, no process connection

4/242 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

■ Overview ■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves set-up and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Start-up is easy using the Quick Start wizard with few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6.
• Key Applications: applications within the Food, Beverage,
Chemical and Pharmaceutical industries where sanitary,
aseptic or hygienic approvals are required or easy install/ 4
clean flush antennas are preferable, such as ice cream,
The SITRANS LR250 hygienic encapsulated antenna is a 2 wire fruit juice, milk, beer, and pharmaceutical or chemical
25 GHz pulse radar level transmitter with sanitary and hygienic additives and ingredients.
approvals for continuous monitoring of liquids, slurries and
pastes within the Food, Beverage, chemical, and pharmaceuti- ■ Configuration
cal industries to a range of 20 m (66 ft) - antenna dependent
(Picture shown with accessories sold separately).
Installation

■ Benefits
• Fully encapsulated horn antenna design with FDA approved Note:
and USP Class VI compliant, TFM 1600 PTFE lens. • Beam angle is the width of the
• < 0.8  Ra surface finish for maximum cleanability and cone where the energy density
hygiene requirements commonly required in sanitary environ- is half of the peak energy 3"/DN 80/80A
density. or larger
ments
• The peak energy density is
• Chemically resistant TFM 1600 PTFE lens is also suitable for directly in front of and in line 9.6° 2"/DN 50
aggressive or corrosive materials with the antenna. /50A
• There is a signal transmitted 12.8°
• Approved device in accordance with 3-A, EHEDG EL Class I
and/or EHEDG EL Aseptic Class I outside of the beam angle;
therefore false targets may be
• Cost effective replacement for transmitters made of exotic detected.
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play set-up using the intuitive Quick Start Mounting unit on vessel Mounting on a nozzle
Wizard
• Industry standard process connections including ISO 2852,
DIN 11851, DIN 11864-1, DIN 11864-2, DIN 11864-3 and
Tuchenhagen Varivent Type F and N
l
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 2 inch (50 mm) process
connection/antenna allow for easy mounting
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Communication using HART, PROFIBUS PA, d
or FOUNDATION Fieldbus
Nozzles should be
• Process Intelligence signal processing for improved maximum l/d ratio 1:1
measurement reliability and Auto False-Echo Suppression of (Eg. 50 mm length,
fixed obstructions 50 mm diameter)
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM, SITRANS LR250 Hygienic Encapsulated Antenna Installation, dimen-
Emerson AMS, or Field Device Tools, such as PACTware or sions in mm (inch)
Fieldcare via SITRANS DTM.
• Functional Safety (SIL 2). Device suitable for use in accor-
dance with IEC 61508 and IEC 61511

Siemens FI 01 · 2015 4/243


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

■ Technical specifications
Mode of Operation Process connections
Measuring principle Radar level measurement Hygienic/Sanitary connections • 2", 3" & 4" Sanitary Clamp according
to ISO 2852
Frequency K-band (25.0 GHz) • DN 50, DN 80 & DN 100 Aseptic/
Minimum measuring range 50 mm (2 inch) from end of antenna Hygienic threaded to DIN 11864-1
[Form A]
Maximum measuring range 20 m (66 ft) • DN 50, DN 80 & DN 100 Aseptic/
Hygienic flanged to DIN 11864-2
Output
[Form A]
HART Version 5.1 • DN 50, DN 80 & DN 100 Aseptic/
• Analog output 4 ... 20 mA Hygienic Clamp according to
DIN 11864-3 [Form A]
• Accuracy ± 0.02 mA
• DN 50, DN 80 & DN 100 Hygienic
• Fail-safe • Programmable as high low or hold Union according to DIN 11851
(loss of echo) • Type F (50 mm) & Type N (68 mm)
• NE 43 programmable Tuchenhagen Varivent
PROFIBUS PA Profile 3.01 Power supply
• Function blocks 2 Analog Input (AI)

4
4 ... 20 mA/HART Nominal 24 V DC (max. 30 V DC) with
FOUNDATION Fieldbus H1 max. 550 
• Functionality Basic or LAS PROFIBUS PA • 15 mA
• Version ITK 5.2.0 • Per IEC 61158-2
• Function blocks 2 Analog Input (AI)
FOUNDATION Fieldbus • 20.0 mA
Performance (according to refer- • Per IEC 61158-2
ence conditions IEC60770-1)
Certificates and approvals
Maximum measured error • > 500 mm from sensor reference
point: 3 mm (0.118 inch) General CSAUS/C, CE, FM, NE 21, RCM
• < 500 mm from sensor reference Radio FCC, Industry Canada and Europe
point: 25 mm (1 inch) ETSI EN 302-372, RCM
Influence of ambient temperature < 0.003 %/K Hazardous
Rated operating conditions • Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T4 Ga/Gb,
Ex ia ta IIIC T100 °C Da
Installation conditions • Increased Safety (Brazil) INMETRO Ex e ia mb IIC T4 Ga/Gb,
Location Indoor/outdoor Ex ia ta IIIC T100 °C Da
• Intrinsically Safe (Brazil) INMETRO Ex ia IIC T4 Ga, Ex ia ta
Ambient conditions (enclosure) IIIC T100 °C Da
Ambient temperature -40 ... +80 °C (-40 ... +176 °F) • Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Installation category I Groups E, F, G; Class III T4
Pollution degree 4 • Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Medium conditions Groups E, F, G; Class III T4
Dielectric constant r  1.6 (antenna dependent) • Non-incendive (Canada/USA) CSA/FM Class I, Div. 2,
Groups A, B, C, D T5
Process temperature -40 ... +170 °C (-40 ... +338 °F) at
process connection • Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T4 Ga/Gb,
(China) Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20
Process pressure See Pressure/Temperature curves for T90 IP67 DIP A20 TA90 ºC
more information • Intrinsically Safe (China) NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90
Design IP67 DIP A20 TA90 ºC
• Non-sparking (China) NEPSI Ex nA IIC T4 Gc
Enclosure • Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 Ga ATEX II 1D
• Material Aluminum, polyester powder coated Ex ia ta IIIC T100 °C Da
• Cable inlet 2 x M20x1.5 or 2 x ½" NPT • Non-sparking (Europe) ATEX II 3G Ex nA IIC T4 Gc
Degree of protection Type 4X/NEMA 4X, Type 6/NEMA 6, • Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D
IP67, IP68 Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC
T100 °C Da
Weight (dependent on process con- • Approx. 4.7 kg (10.4 lb) for • Increased Safety IECEx/ATEX II 1/2 GD, 1D, 2D,
nection) 2" ISO 2852 (smallest size) (International/Europe) Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC
• Approx. 7.9 kg (17.4 lb) for T100 °C Da
DN 100 DIN 11864-2 (largest size)
• Intrinsically Safe (International) IECEx/ATEX II 1 G Ex ia IIC T4 Ga,
Display (local) Graphic local user interface including IECEX/ATEX II 1D Ex ia ta IIIC
quick start wizard and echo profile T100 °C Da
display • Explosion Proof (Russia) GOST-R Ex d
Antenna • Increased Safety (Russia) GOST-R Ex e
• Material Stainless steel 316L (1.4435 or • Intrinsically Safe (Russia) GOST-R Ex ia
1.4404) and TFM 1600 PTFE Lens Hygienic/Sanitary EHEDG EL Class I
(lens is the only wetted part)
• Lens surface finish (Ra) 0.8 µm EHEDG EL Aseptic Class I

4/244 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Programming
Intrinsically Safe Siemens handheld Infrared receiver
programmer
• Approvals for handheld program- IS model:
mer ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1.,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C
IECEx SIR 09.0073
Handheld communicator HART communicator 375/475
PC • SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection into
FDT, such as PACTware or Fieldcare)
Display (local) Graphic local user interface including
quick start wizard and echo profile

4
displays

Siemens FI 01 · 2015 4/245


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LR250 hygienic encapsulated antenna 7ML5433- SITRANS LR250 hygienic encapsulated antenna 7ML5433-
2-wire, 25 Ghz pulse radar level transmitter for con- 77 7 7 0 - 7A 77 2-wire, 25 Ghz pulse radar level transmitter for con- 77 7 7 0 - 7A 77
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, up to a range of 20 m (66 ft) and pressure, up to a range of 20 m (66 ft)
(Antenna dependant). Ideal for Hygienic applica- (Antenna dependant). Ideal for Hygienic applica-
tions including small vessels and low dielectric tions including small vessels and low dielectric
media. media.
Click on the Article No. for the online configura- Communication
tion in the PIA Life Cycle Portal. PROFIBUS PA ¢ 1
Hygienic/Sanitary Approvals 4 ... 20 mA HART, start-up at < 3.6 mA ¢ 2
¢ 1
EHEDG EL Class I1) FOUNDATION Fieldbus ¢ 3
EHEDG EL Aseptic Class I1) ¢ 2
3-A (Tuchenhagen connections only - FC ... FF) 2)3)¢ 3 Enclosure (with Cable Inlets)
EHEDG EL Class I & 3-A (excludes Tuchenhagen ¢ 4 Aluminum, Epoxy paint, 2 X ½" NPT ¢ 0
connections)4)
Aluminum, Epoxy paint, 2 X M20 x 1.5 ¢ 1
Process Connection Types (all types have
4 TFM1600 PTFE lens) Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, RCM ¢ A
316L st/st [1.4435 or 1.4404]
Intrinsically Safe: CSA/FM Class I, Div. 1, Groups ¢ B
2" Sanitary Clamp according to ISO 28525) ¢ AA
¢ A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III
3" Sanitary Clamp according to ISO 2852 AB
¢
T4 FCC, Industry Canada
4" Sanitary Clamp according to ISO 2852 AC
Intrinsically Safe: IECEx/ATEX II 1 GD Ex ia IIC T4 ¢ C
316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301)
Ga, Ex ia ta IIIC T100 °C Da, INMETRO Ex ia IIC T4
DN 50 Aseptic/Hygienic nozzle/ slotted nut BA Ga, Ex ia ta IIIC T100 °C Da, CE, R&TTE, RCM
(instrument side) to DIN 11864-1 [Form A]5) Non-incendive: CSA/FM Class I, Div. 2, ¢ D
DN 80 Aseptic/Hygienic nozzle/ slotted nut BB Groups A, B, C, D T5, FCC, Industry Canada
(instrument side) to DIN 11864-1 [Form A] Non Sparking: ATEX II 3G Ex nA IIC T4 Gc, CE, ¢ E
DN 100 Aseptic/Hygienic nozzle/ slotted nut BC R&TTE, RCM
(instrument side) to DIN 11864-1 [Form A] Increased Safety: IECEx/ATEX II 1/2 GD, 1D, ¢ F
316L st/st [1.4435 or 1.4404] 2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C
DN 50 Aseptic/Hygienic flanged to DIN 11864-2 CA Da, INMETRO Ex e ia mb IIC T4 Ga/Gb,
[Form A]5) Ex ia ta IIIC T100 °C Da, CE, R&TTE, RCM6)
DN 80 Aseptic/Hygienic flanged to DIN 11864-2 CB Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ¢ G
[Form A] ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da,
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC
DN 100 Aseptic/Hygienic flanged to DIN 11864-2 CC T100 °C Da, CE, R&TTE, RCM6)
[Form A]
Explosion proof: CSA/FM Class I, II and III, Div. 1, ¢ H
316L st/st [1.4435 or 1.4404] Groups A, B, C, D, E, F, G, FCC, Industry Canada6)
DN 50 Aseptic/Hygienic Clamp according to DA Non Sparking: NEPSI Ex nA IIC T4 Gc ¢ K
DIN 11864-3 [Form A]5)
Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 ¢ L
DN 80 Aseptic/Hygienic Clamp according to DB T90 IP67 DIP A20 TA 90 ºC
DIN 11864-3 [Form A]
Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, ¢ M
DN 100 Aseptic/Hygienic Clamp according to DC Ex iaD 20 T90 IP67 DIP A20 TA 90 ºC6)
DIN 11864-3 [Form A]
Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, ¢ N
316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301) Ex iaD 20 T90 IP67 DIP A20 TA 90 ºC6)
DN 50 Hygienic nozzle/ slotted nut EA
Pressure Rating
(instrument side) to DIN 118515)
EB Rating per pressure/temperature curves in instruc- ¢ 0
DN 80 Hygienic nozzle/ slotted nut tion manual
(instrument side) to DIN 11851
EC ¢ We can offer shorter delivery times for configurations designated with the
DN 100 Hygienic nozzle/ slotted nut Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
(instrument side) to DIN 11851
316L st/st [1.4435 or 1.4404]
Type F (50 mm) Tuchenhagen Varivent FA
(EHEDG only)5)
Type N (68 mm) Tuchenhagen Varivent FB
(EHEDG only)5)
Type F (50 mm) Tuchenhagen Varivent FC
[3-A only & EPDM process seal -40 °C ... 120 °C
(-40 °F ... 248 °F )]5)
Type N (68 mm) Tuchenhagen Varivent FD
[3-A only & EPDM process seal -40 °C ... 120 °C
(-40 °F ... 248 °F)]5)
Type F (50 mm) Tuchenhagen Varivent FE
[3-A only & FKM process seal -20 °C ... 170 °C
(-4 °F ... 338 °F)]5)
Type N (68 mm) Tuchenhagen Varivent FF
[3-A only & FKM process seal -20 °C ... 170 °C
(-4 °F ... 338 °F)]5)
EXCLUDE Process Connection - Electronics Head YY
assembly spare only (select all other options as
normal)

4/246 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs Operating Instructions for
FOUNDATION Fieldbus device
Please add "-Z" to Article No. and specify Order
code(s). English A5E32221411
Electrical Connection cable entry: German A5E32376112
Plug M12 (IP 67 rating) with mating connector2)7)8) ¢ A50 Note: The Operating Instructions should be orde-
red as a separate line item on the order.
Plug 7/8" (IP 67 rating) with mating Connector2)8)9) ¢ A55
Compact Operating Instructions for
Test Certificates FOUNDATION Fieldbus device
Manufacturer's Test Certificate M to DIN 55350, ¢ C11 English, French, German, Spanish, Italian, Dutch, A5E33472700
Part 18 and to ISO 9000 Danish, Finnish, Greek, Portuguese (Portugal),
Inspection Certificate 3.1 of EN 10204 ¢ C12 Swedish

Functional Safety English, Bulgarian, Czech, Estonian, Hungarian, A5E33472738


Latvian, Lithuanian, Polish, Romanian, Slovakian,
Functional Safety (SIL 2). Device suitable for use in ¢ C20 Slovenian
accordance with IEC 61508 and IEC 615116)10)
This device is shipped with the Siemens Milltronics

4
Namur manual DVD containing the ATEX Compact Opera-
Namur NE43 compliant, device preset to failsafe ¢ N07 ting Instructions and Operating Instructions library.
< 3.6 mA6) Accessories
Tagging
Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK
Stainless steel tag [69 mm x 50 mm (LUI enabled)
(2.71 x 1.97 inch)]
Measuring-point number / identification ¢ Y15 HART modem/USB 7MF4997-1DB
(max. 27 characters) specify in plain text (for use with a PC and SIMATIC PDM)

Operating Instructions for HART/mA device Article No. One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 ... +80 °C (-40 ... +176 °F),
English A5E32220602 HART (two are required)6)
German A5E32376088 One metallic cable gland M20x1.5, 7ML1930-1AQ
Note: The Operating Instructions should be orde- rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
red as a separate line item on the order. and FOUNDATION Fieldbus (two are required)8)

Compact Operating Instructions for HART/mA SITRANS RD100, loop powered display - 7ML5741-...
device see Chapter 7

English, French, German, Spanish, Italian, Dutch, A5E33469191 SITRANS RD200, universal input display with 7ML5740-...
Danish, Finnish, Greek, Portuguese (Portugal), Modbus conversion - see Chapter 7
Swedish SITRANS RD300, dual line display with totalizer 7ML5744-...
English, Bulgarian, Czech, Estonian, Hungarian, A5E33469171 and linearization curve and Modbus conversion -
Latvian, Lithuanian, Polish, Romanian, Slovakian, see Chapter 7
Slovenian SITRANS RD500 web, universal remote monitoring 7ML5750-...
This device is shipped with the Siemens Milltronics solution for instrumentation - see Chapter 7
manual DVD containing the ATEX Compact Opera- For applicable back up point level switch -
ting Instructions and Operating Instructions library. see point level measurement section
Operating Instructions for PROFIBUS PA device ¢ We can offer shorter delivery times for configurations designated with the
English A5E32221386 Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

German A5E32376094 1)
Available with process connection options AA ... FB & YY only
Note: The Operating Instructions should be 2)
ordered as a separate line item on the order. Available with Approval options A, B, C, L only
3)
Available with Process connection FC ... FF only
Compact Operating Instructions for 4)
PROFIBUS PA device Available with process connection options AA ... EC & YY only
5)
Max. range 10 m (32.8 ft), dk > 3 [20 m (66 ft) and dk > 1.6 if installed in a
English, French, German, Spanish, Italian, Dutch, A5E33469239 stillpipe]
Danish, Finnish, Greek, Portuguese (Portugal), 6)
Swedish Applicable with Communication option 2 only
7)
Available with Enclosure option 1 only
English, Bulgarian, Czech, Estonian, Hungarian, A5E33472685 8)
Latvian, Lithuanian, Polish, Romanian, Slovakian, Available with Communication options 1 & 3 only.
Slovenian 9)
Available with Enclosure option 0 only
10) Available with Approval options A, B, C, D, E, K, L only
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Compact Opera-
ting Instructions and Operating Instructions library.

Siemens FI 01 · 2015 4/247


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

■ Characteristic curves
DIN 11851 Sanitary/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100
DIN 11864-1 Aseptic/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100

30 bar (435 psi)

20 bar (290 psi)

4 10 bar (145 psi)

1 -40°F 14°F 100°F 200°F 300°F 400°F


(-40°C) (-10°C) (38°C) (93°C) (149°C) (204°C)
-1 bar (-14.5 psi) T
-50°C RT 50°C 100°C 150°C 200°C
(-58°F) 0°C (122°F) (212°F) (302°F) (392°F)
(32°F)
-29°C 170°C
1 Atmospheric
(-20°F) (338°F)
P Allowable operating pressures
T Allowable operating temperatures

SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves

DIN 11864-2 Aseptic/Hygienic flanged: DN 50, DN 80, and DN 100

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)

1 -40°F 14°F 100°F 200°F 300°F 400°F


(-40°C) (-10°C) (38°C) (93°C) (149°C) (204°C)
-1 bar (-14.5 psi) T
-50°C RT 50°C 100°C 150°C 200°C
(-58°F) 0°C (122°F) (212°F) (302°F) (392°F)
(32°F) 170°C
-29°C (338°F)
(-20°F)
1 Atmospheric
P Allowable operating pressures Note: For pressure applications, all attachment hardware must be suitably rated.
T Allowable operating temperatures

SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves

4/248 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

DIN 11864-3 Aseptic/Hygienic clamp: DN 50, DN 80, and DN 100


IS0 2852 Sanitary/Hygienic clamp: 2", 3", and 4"
Tuchenhagen Varivent face seal clamp: Type N (68 mm) and Type F (50 mm)

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi) 4


1 -40°F 14°F 100°F 200°F 300°F 400°F
(-40°C) (-10°C) (38°C) (93°C) (149°C) (204°C)
-1 bar (-14.5 psi) T
-50°C RT 50°C 100°C 150°C 200°C
(-58°F) 0°C (122°F) (212°F) (302°F) (392°F)
(32°F)
-29°C 170°C
1 Atmospheric
(-20°F) (338°F)
P Allowable operating pressures
T Allowable operating temperatures
Note: For pressure applications, all clamps must be rated accordingly.

SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves

Siemens FI 01 · 2015 4/249


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

■ Dimensional drawings
Hygienic encapsulated antenna (2" ISO 2852 sanitary clamp)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar
274.2
(10.80)
225.7
(8.89)

Process
connection
Sensor
reference
point

Ø44.0
(1.73) 11.0
(0.43)
Ø64.0
(2.52)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/250 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (3" ISO 2852 sanitary clamp)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

167.0
(6.57) 4
153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)
Retaining
collar 343.2
(13.51)

291.2
(11.46)

Process
connection
Sensor
reference
point

14.5
Ø74.7 (0.57)
(2.94)
Ø91.0
(3.58)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/251


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (4" ISO 2852 sanitary clamp)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar

343.2
(13.51)

291.2
(11.46)

Process
connection
Sensor
reference
point

Ø74.7
(2.94) 14.5
Ø119.0 (0.57)
(4.69)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/252 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 50 nozzle/slotted nut to DIN 11851)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0
(7.01) Retaining
collar
274.2
(10.80)
225.7
Threaded nut (8.89)

Sensor
reference
point

Ø44.0
(1.73) 11.0
Ø57.6 (0.43)
(2.27)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
Ø63.7 purposes only.
(2.51)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/253


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 80 nozzle/slotted nut to DIN 11851)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

4 167.0
(6.57)
153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)

Retaining
collar
343.2
(13.51)

291.2
(11.46)
Threaded nut

Sensor
reference
point

Ø74.7
(2.94) 14.5
(0.57)
Ø88.6
(3.49)
Ø94.7 Note: Cut out of process connection and placement of threaded nut are shown for illustration
(3.73) purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/254 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 100 nozzle/slotted nut to DIN 11851)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

167.0
4
(6.57)

153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)
Retaining
collar
343.2
(13.51)
291.2
Threaded nut
(11.46)

Sensor
reference
point

Ø74.7 14.5
(2.94) (0.57)
Ø107.6
(4.24)
Ø113.7
Note: Cut out of process connection and placement of threaded nut are shown for illustration
(4.48)
purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/255


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN 11864-1)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

4 167.0
(6.57)

153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)
274.2
Retaining (10.80)
collar
225.7
Threaded nut (8.89)

Sensor
reference
point

Ø44.0
(1.73) 11.0
Ø66.9 (0.43)
(2.63)
Ø72.0
(2.83) Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/256 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN 11864-1)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

167.0
4
(6.57)

153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)
Retaining
collar
343.4
(13.52)

291.3
Threaded nut (11.47)

Sensor
reference
point

Ø74.7
(2.94) 14.5
(0.57)
Ø98.9
(3.89)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
Ø104.0 purposes only.
(4.09)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/257


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN 11864-1)

50.0 1/2" NPT cable entry (or alternatively, M20


(2.00) cable gland)

Threaded cover

4
167.0
(6.57)

153.0 90.0
(6.02) (3.54)

Enclosure

178.0
(7.01)
Retaining
collar
343.4
(13.52)

Threaded nut 291.3


(11.47)

Sensor
reference
point

Ø74.7 14.5
(2.94) (0.57)
Ø118.9
(4.68)
Ø124.0
(4.88)
Note: Cut out of process connection and placement of threaded nut are shown for illustration
purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/258 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 50 aseptic flange to DIN 11864-2)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0 90.0
(6.02) (3.54)

Enclosure

178.0 Retaining
(7.01) collar
274.2
(10.80)

225.7
(8.89)

Flange
Sensor
reference
point

Ø44.0
(1.73)
11.0
Ø63.0 (0.43)
(2.48)
Ø94.5
(3.72)

Note: Cut out of process connection and flange are shown for illustration purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/259


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 80 aseptic flange to DIN 11864-2)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4 167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0
Retaining
(7.01)
collar

343.2
(13.51)

291.2
(11.46)

Flange
Sensor
reference
point

Ø74.7
(2.94) 14.5
Ø94.5 (0.57)
(3.72)
Ø133.0
(5.24)
Note: Cut out of process connection and flange are shown for illustration purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/260 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 100 aseptic flange to DIN 11864-2)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar

343.2
(13.51)
291.2
(11.46)

Flange
Sensor
reference
point

Ø74.7
(2.94) 14.5
Ø113.5 (0.57)
(4.47)

Ø159.0
(6.26) Note: The cut out of the process connection and the flange are shown for illustration purposes
only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/261


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN 11864-3)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0
(7.01) Retaining
collar
273.7
(10.78)
225.2
(8.87)

Process
connection Sensor
reference
point

Ø44.0
(1.73)
11.0
Ø63.0
(0.43)
(2.48)
Ø77.5
(3.05)
Note: Cut out of process connection is shown for illustration purposes only.

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/262 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN 11864-3)

50.0
(2.00) 1/2" NPT cable entry
(or alternatively, M20 cable gland)

Threaded cover

167.0
4
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0
Retaining
(7.01)
collar

343.2
(13.51)
291.2
(11.46)

Process Sensor
connection reference
point

Ø74.7
(2,94)
14.5
Ø94.5 (0.57)
(3.72)
Ø106.0
Note: Cut out of process connection is shown for illustration purposes only.
(4.17)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/263


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN 11864-3)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar

343.2
(13.51)

291.2
(11.46)

Process
connection
Sensor
reference
point

Ø74.7
(2.94) 14.5
Ø113.5 (0.57)
(4.47)
Ø130.0 Note: Cut out of process connection is shown for illustration purposes only.
(5.12)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/264 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (Tuchenhagen Type F, 50 mm)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar
276.7
(10.89)
232.7
(9.16)

Process
connection

Sensor
reference
point

Ø50.0
(2.00)
Ø66.0 6.5
(2.60) (0.26)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

Siemens FI 01 · 2015 4/265


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

Hygienic encapsulated antenna (Tuchenhagen Type N, 68 mm)

50.0 1/2" NPT cable entry


(2.00) (or alternatively, M20 cable gland)

Threaded cover

4
167.0
(6.57)
153.0
(6.02) 90.0
(3.54)

Enclosure

178.0 Retaining
(7.01) collar
274.2
(10.80)
225.5
(8.88)

Process
connection

Sensor
reference
point

Ø 68.0
(2.68)
Ø84.0 11.2
(3.31) (0.44)

SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch)

4/266 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Antenna

■ Schematics
Connect the wires to the Hand Programmer
terminals as shown: the
polarity is identified on the
terminal block.

Shield for HART, 4


PROFIBUS PA , and Part number:
Gland 7ML1930-1BK
FOUNDATION Fieldbus
Intrinsically Safe
versions only.
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR250 connections

Siemens FI 01 · 2015 4/267


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR250 Hygienic Encapsulated Specials

■ Selection and ordering data


SITRANS LR250 hygienic encapsulated Specials SITRANS LR250 hygienic encapsulated Specials
Article No. Article No.
For "Electronics Head only" follow the standard Kit 3" ISO 2852 tank connection, Clamp, A5E32910697
configuration and choose YY option on posi- Cleanable EPDM Seal Class II
tions 9 and 10 of the full part number. Kit 4" ISO 2852 tank connection, Clamp, A5E32910708
For example: 7ML5433-1YY20-1AA0 will order Cleanable EPDM Seal Class II
an electronics head for the following: Kit DN 50 DIN 11851 SC tank connection, A5E32910746
EHEDG EL Class 1 approval, 4 ... 20mA HART, EPDM Seal Class II11)
M20 cable entries, General purpose Haz Loc Kit DN 80 DIN 11851 SC tank connection, A5E32910771
approval, pressure rating as per manual. EPDM Seal Class II11)
Spare Lens Kits (Lens and O-ring) Kit DN 100 DIN 11851 SC tank connection, A5E32910780
EPDM Seal Class II11)
Kit, 2 inch, ISO2852, HEA, Lens, silicone A5E32572731
Kit DN 50 DIN 11851 SC tank connection, A5E32910784
secondary O-ring
FKM Seal Class II
Kit, 3 inch, ISO2852, HEA, Lens, silicone A5E32572745
Kit DN 80 DIN 11851 SC tank connection, A5E32910789
4
secondary O-ring
Kit, 4 inch, ISO2852, HEA, Lens, silicone A5E32572747 FKM Seal Class II
secondary O-ring Kit DN 100 DIN 11851 SC tank connection, A5E32910790
FKM Seal Class II
Kit, DN 50, DIN11851, HEA, Lens, silicone A5E32572758
Kit DN 50 DIN 11864-2 Form A tank connection, A5E32910791
secondary O-ring
M8 Hardware (nut/bolt/washer),
Kit, DN 80, DIN11851, HEA, Lens, silicone A5E32572770 EPDM Seal Class II
secondary O-ring
Kit, DN 100, DIN11851, HEA, Lens, silicone A5E32572772 Kit DN 80 DIN 11864-2 Form A tank connection, A5E32910793
secondary O-ring M10 Hardware (nut/bolt/washer),
EPDM Seal Class II
Kit, DN 50, DIN11864-1, HEA, Lens, silicone A5E32572773 Kit DN 100 DIN 11864-2 Form A tank connection, A5E32910799
secondary O-ring M10 Hardware (nut/bolt/washer),
Kit, DN 80, DIN11864-1, HEA, Lens, silicone A5E32572779 EPDM Seal Class II
secondary O-ring Kit DN 50 DIN 11864-2 Form A tank connection, A5E32910805
Kit, DN 100, DIN11864-1, HEA, Lens, silicone A5E32572782 M8 Hardware (nut/bolt/washer), FKM Seal Class I
secondary O-ring
Kit DN 80 DIN 11864-2 Form A tank connection, A5E32910809
Kit, DN 50, DIN11864-2/3, HEA, Lens, silicone A5E32572785 M10 Hardware (nut/bolt/washer), FKM Seal Class I
secondary O-ring Kit DN 100 DIN 11864-2 Form A tank connection, A5E32910812
Kit, DN 80, DIN11864-2/3, HEA, Lens, silicone A5E32572790 M10 Hardware (nut/bolt/washer), FKM Seal Class I
secondary O-ring Kit DN 50 DIN 11864-3 Form A tank connection, A5E32910813
Kit, DN 100, DIN11864-2/3, HEA, Lens, silicone A5E32572791 Clamp, EPDM Seal Class II
secondary O-ring
Kit DN 80 DIN 11864-3 Form A tank connection, A5E32910814
Kit, Tuchenhagen, Type F, HEA, Lens, silicone A5E32572794 Clamp, EPDM Seal Class II
secondary O-ring Kit DN 100 DIN 11864-3 Form A tank connection, A5E32910815
Kit, Tuchenhagen, Type N, HEA, Lens, silicone A5E32572795 Clamp, EPDM Seal Class II
secondary O-ring Kit DN 50 DIN 11864-3 Form A tank connection, A5E32910816
Clamp, FKM Seal Class I
Accessories (customer side process connec-
tion and FKM and EPDM seal for each size and Kit DN 80 DIN 11864-3 Form A tank connection, A5E32910817
type) Clamp, FKM Seal Class I
Kit DN 50 DIN 11864-1 GS Form A tank connec- A5E32910638 Kit DN 100 DIN 11864-3 Form A tank connection, A5E32910818
tion, EPDM Seal Class II Clamp, FKM Seal Class I
Kit, DN 80 DIN 11864-1 GS Form A tank connec- A5E32910649 Kit Type F, Tuchenhagen, Clamp, EPDM Seal Class A5E33489537
tion, EPDM Seal Class II II (EHEDG only) - no tank connection
Kit, DN 100 DIN 11864-1 GS Form A tank connec- A5E32910657 Kit Type N, Tuchenhagen, Clamp, EPDM Seal A5E33489543
tion, EPDM Seal Class II Class II (EHEDG only) - no tank connection
Kit DN 50 DIN 11864-1 GS Form A tank connec- A5E32910658 Kit Type F, Tuchenhagen, Clamp, FKM Seal Class I A5E33489828
tion, FKM Seal Class I (EHEDG only) - no tank connection
Kit, DN 80 DIN 11864-1 GS Form A tank connec- A5E32910671 Kit Type N, Tuchenhagen, Clamp, FKM Seal A5E33489830
tion, FKM Seal Class I Class I (EHEDG only) - no tank connection
11)
Kit, DN 100 DIN 11864-1 GS Form A tank connec- A5E32910681 Class II for low fat applications when EPMD seal used on DIN 11851.
tion, FKM Seal Class I
Kit 2" ISO 2852 tank connection, Clamp, A5E32910686
Cleanable EPDM Seal Class II

4/268 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260

■ Overview ■ Configuration
Mounting on
a nozzle

Min. clearance:
10 (0.4)
Installation Min. 1 000 (39) 4
SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter
for continuous monitoring of solids and liquids in storage vessels
including extreme levels of dust and high temperatures,
to a range of 30 m (98.4 ft).

■ Benefits Emission
cone
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small horn antennas
mounted easily in nozzles Beam angle:
• Communication using HART or PROFIBUS PA 2" horn = 15°
3" horn = 10°
• Process Intelligence signal processing for improved 4" horn = 8°
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM

■ Application
SITRANS LR260 includes a graphical local user interface (LUI)
that improves setup and operation using an intuitive Quick Start Positioning with
easy Aimer
Wizard, and echo profile displays for diagnostic support.
Start-up is easy using the Quick Start wizard with a few parame-
ters required for basic operation.
SITRANS LR260’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR260 measures virtually any solids material to a
range of 30 m (98.4 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, flour, coal, solids and liquids bulk storage vessels,
and other applications.

SITRANS LR260 installation, dimensions in mm (inch)

Siemens FI 01 · 2015 4/269


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260

■ Technical specifications
Mode of operation Design
Measuring principle Pulse radar level measurement Enclosure
Frequency K-band (25.0 GHz) • Construction Aluminum, polyester powder-coated
• Conduit entry 2 x M20x1.5 or 2 x ½" NPT
Minimum detectable distance 0.05 m (2 inch) from end of horn Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA 6,
Maximum measuring range 1) IP67, IP68
Weight < 8.14 kg (17.9 lb) including 4" flange
• Solids • 2" horn: 10 m (32.8 ft) and standard Easy Aimer with 4" horn
• 3" horn: 20 m (65.6 ft) antenna
• 4" horn: 30 m (98.4 ft) Display (local) Graphic LCD, with bar graph repre-
• Liquids • 2" horn: 20 m (65.6 ft) senting level
• 3" horn: 30 m (98.4 ft) Flange and horn (easy aimer model)
• 4" horn: 30 m (98.4 ft)
• Material 304 stainless steel
Output - HART • Horn antenna 2" horn
Power • 4 ... 20 mA (± 0.02 mA accuracy) 3" horn
Fail signal • Nominal 24 V DC (max. 30 V DC) 4" horn
Load • 3.6 mA ... 23 mA;
4
Process connections
or last value 230 ... 600 
• Universal flanges 2) 2 inch/50 mm, 3 inch/80 mm,
Output - PROFIBUS PA • Per IEC 61158-2 4 inch/100 mm, 6 inch/150 mm
• 15.0 mA Mechanical (Threaded Connection
• Profile version 3.01, Class B model)
Performance (according to refer- • Threaded connection 2" NPT (ASME B1.20.1),
ence conditions IEC60770-1) R (BSPT, EN 10226-1) or
• Materials
Maximum measured error (including • 25 mm (1 inch) from minimum G (BSPP, EN ISO 228-1)
hysteresis and non-repeatability) detectable distance to 300 mm 316L/1.4404 or 316L/1.4435 stainless
(11.8 inch) steel PTFE emitter
• Remainder of range = 10 mm
(0.39 inch) or 0.1 % of Certificates and approvals
spa(whichever is greater) General CSAUS/C, CE, FM
Rated operating conditions Radio Europe (R&TTE), FCC,
Installation conditions Industry Canada, RCM
• Location Indoor/outdoor Hazardous CSA/FM Class II, Div. 1,
Groups E, F, G, Class III
Ambient conditions (enclosure) ATEX II 1D, 1/2D, 2D Ex ta IIIC
• Ambient temperature -40 ... +80 °C (-40 ... +176 °F) T100 ºC Da
• Installation category I IECEx/ATEX II 1 GD Ex ia IIC T4 Ga,
• Pollution degree 4 Ex ta IIIC T100 ºC Da
Medium conditions CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G
Dielectric constant r r > 1.6, antenna and application SABS ARP0108 Ex ia IIC T4 Ga
dependent
Programming
Process temperature -40 ... +200 °C (-40 ... +392 °F)
Intrinsically Safe Siemens handheld Infrared receiver
Process pressure • 0.5 bar g (7.25 psi g) maximum programmer IS model:
• 3 bar g (43.5 psi g) optional with • Approvals for handheld ATEX II 1GD Ex ia IIC T4 Ga
80 °C (176 °F) temperature max programmer Ex iaD 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G,
T6 Ta = 50 °C
Handheld communicator HART communicator 375
PC SIMATIC PDM
Display (local) Graphic local user interface including
quick start wizard and echo profile
displays
1)
From sensor reference point
2)
Universal flange mates with EN 1092-1 (PN 16)/ASME B16.5 (150 lb)/
JIS 2220 (10K) bolt hole pattern

4/270 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR260 7ML5427- Further designs
2-wire, 25 GHz pulse radar level transmitter for con- Please add "-Z" to Article No. and specify Order
tinuous monitoring of solids to a range of 30 m 0 7 7 7 0 - 77 7 7
(98.4 ft). code(s).
Order handheld programmer separately Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
Click on the Article No. for the online configura- (max. 27 characters); specify in plain text
tion in the PIA Life Cycle Portal.
Process connection Manufacturer's test certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Universal flat faced flange fits ANSI/DIN/JIS Inspection Certificate Type 3.1 per EN 102044) C12
flanges, Easy Aimer with integral (Easy Aimer ball)
2 inch/50 mm A Operating Instructions for HART/mA device Article No.
3 inch/80 mm B English 7ML1998-5KE03
4 inch/100 mm C German A5E34942821
6 inch/150 mm D Note: The Operating Instructions should be
ordered as a separate line item on the order.
Threaded connection
Multi-language Quick Start manual A5E32106122
2" NPT (ASME B1.20.1) (tapered thread)1)2)5)
4
E This device is shipped with the Siemens Milltronics
R 2" [(BSPT), EN 10226-1] (tapered thread)1)2)5) F manual DVD containing the ATEX Quick Start and
Operating Instructions library.
G 2" [(BSPT), EN ISO 228-1] (parallel thread)1)2)5) G
Operating Instructions for PROFIBUS PA device
Antenna
2" Horn antenna, fits 50 mm or 2" nozzles1) A English 7ML1998-5KF03
German
2" Horn antenna with 100 mm extension1) B Note: The Operating Instructions should be
A5E34957877
2" Horn antenna with 200 mm extension1) C ordered as a separate line item on the order.
2" Horn antenna with 500 mm extension1)2) D Multi-language Quick Start manual A5E32114443
This device is shipped with the Siemens Milltronics
2" Horn antenna with 1 000 mm extension1)2) E manual DVD containing the ATEX Quick Start and
3" Horn antenna, fits 80 mm or 3" nozzles3) F Operating Instructions library.
3" Horn antenna with 100 mm extension3) G Accessories
3" Horn antenna with 200 mm extension3) H One metallic cable gland M20x1.5, 7ML1930-1AP
3" Horn antenna with 500 mm extension2)3) J rated -40 ... +80 °C (-40 ... +176 °F), HART
3" Horn antenna with 1 000 mm extension2)3) K One metallic cable gland M20x1.5, 7ML1930-1AQ
4" Horn antenna, fits 100 mm or 4" nozzles L rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA
4" Horn antenna with 100 mm extension M Handheld programmer, Infrared, Intrinsically Safe 7ML1930-1BK
4" Horn antenna with 200 mm extension N Dust cap, PTFE, for 2 inch/50 mm horn 7ML1930-1DE
4" Horn antenna with 500 mm extension2) P Dust cap, PTFE, for 3 inch/75 mm horn 7ML1930-1BL
4" Horn antenna with 1 000 mm extension2) Q Dust cap, PTFE, for 4 inch/100 mm horn 7ML1930-1BM
Purge (self cleaning) connection
No purge connection HART modem/USB 7MF4997-1DB
0 (for use with a PC and SIMATIC PDM)
Purge connection 1 SITRANS RD100, loop powered display - 7ML5741-...
Output/communication see Chapter 7
4 ... 20 mA, HART 0 SITRANS RD200, universal input display with 7ML5740-...
PROFIBUS PA 1 Modbus conversion - see Chapter 7
Cable inlet SITRANS RD300, dual line display with totalizer 7ML5744-...
2 x M20x1.5 and linearization curve and Modbus conversion -
A
see Chapter 7
2 x ½" NPT B
Note: Polymeric cable glands will be provided with SITRANS RD500 web, universal remote monitoring 7ML5750-...
M20 devices. solution for instrumentation - see Chapter 7
Approvals For applicable back up point level switch -
see point level measurement section
General purpose, CSAUS/C, FM, Industry Canada, A
FCC, CE, R&TTE, RCM Note: Products shipped with plastic cable gland,
CSA/FM Class II, Div. I, Groups E, F, G, Class III, B rated to -20 °C. If -40 °C rating required,
Industry Canada, FCC, RCM then metallic cable gland is recommended.
ATEX II 1D, 1/2D, 2D Ex ta IIIC T100 ºC Da, CE, C 1)
Maximum measurement range 10 m (32.8 ft) solids or 20m (65.6ft) liquids
R&TTE, RCM, INMETRO 2)
Available with Purge option 0 only
Non-incendive, CSA/FM Class I, Div. 2, Groups A, D 3)
B, C, D, Industry Canada, FCC, RCM Maximum measurement range 20 m (65.6 ft) solids or 30m (98.4ft) liquids
4)
Intrinsically safe, IECEx/ATEX II 1 GD Ex ia IIC T4 E Available with pressure option 0 only
Ga, Ex ta IIIC T100 ºC Da, R&TTE, RCM 5)
Available with Antenna Options A, B, F, G, L, and M only
Intrinsically safe, CSA/FM Class I, II, III, Div. 1, F 6)
Available with pressure option 0 only
Groups A, B, C, D, E, F, G, Industry Canada, FCC,
RCM
Intrinsically safe, South Africa ARP0108 Ex ia IIC T4 G
Ga
Pressure rating
Rating per Pressure/Temperature curves in 0
manual6)
0.5 bar g (7.25 psi g) maximum 1

Siemens FI 01 · 2015 4/271


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260

■ Characteristic curves
Maximum flange and process temperatures versus allowable ambient temperature

90
Ambient temperature (°C)

80
70
60
50
40
30
20
10

4
0
0 50 100 150 200 250
Process flange surface temperature (°C)

SITRANS LR260 Ambient/Process Flange Surface Temperature Curve

■ Dimensional drawings
Nameplate Enclosure/electronics
268 (10.6)

Optional purge connection


with factory-installed
1/8" NPT plug

Universal slotted flange


Process
device tag
Sensor
reference
point
Optional extension
4" horn: 285 (11.2)
2" horn: 163 (6.4)
3" horn: 228 (9.0)

100/200/500/1000
(3.93/7.87/19.68/39.37) Horn

Optional PTFE dust cap

Clamp screw 49 (1.9)


74.5 (2.9)
97.5 (3.8)

SITRANS LR260, dimensions in mm (inch)

4/272 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260

SITRANS LR260

50 ½" NPT cable entry


(2.0) (or alternatively,
M20 cable gland)

Threaded cover
167 (6.6)
154 (6.1) 90 (3.5)

Enclosure/
196 (7.7) electronics

(6.26)
159
Retaining
281 (11.1)

collar

Optional
4
100 (3.93) Process
device tag Sensor
Horn reference
Extension point
28 (1.1)*

Horn

Horn Horn
O.D. O.D.

Antenna Antenna O.D. Height to sensor reference point Beam angle Measurement
Type range
1-1/2" threaded 2" threaded 3" threaded
connection connection connection
2" horn 47.8 (1.88) N/A 166 (6.55) 180 (7.09) 15 degrees 20 m (65.6 ft)
3" horn 74.8 (2.94) N/A 199 (7.85) 213 (8.39) 10 degrees 20 m (65.6 ft)
4" horn 94.8 (3.73) N/A 254 (10) 268 (10.55) 8 degrees 20 m (65.6 ft)

SITRANS LR260, dimensions in mm (inch)

■ Schematics
Connect the wires to the Hand programmer
terminals as shown: the
polarity is identified on the
terminal block.

Shield for HART and


PROFIBUS PA Part number:
Gland 7ML1930-1BK
intrinsically safe
versions only.

Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

SITRANS LR260 connections

Siemens FI 01 · 2015 4/273


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460

■ Overview ■ Application
SITRANS LR460 provides excellent results even during condi-
tions of extreme dust. The integral Easy Aimer included on the
SITRANS LR460 allows for easy positioning for optimum mea-
surement on solids.
Process Intelligence onboard SITRANS LR460 means advanced
signal processing is harnessed for reliable operation on both
simple and difficult solids application.
SITRANS LR460 features a robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temper-
ature conditions within the vessel.
An optional dust cap is available for sticky solids. Optional air
purging is also available for extremely sticky applications.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
4 remote programming using HART or PROFIBUS PA.
The characteristics of 24 GHz and high signal-to-noise ratio con-
tribute to exceptional signal reflection, regardless of the dielec-
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level trans- tric value of the medium.
mitter with extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of solids up to • Key Applications: long-range dusty applications,
100 m (328 ft). It is ideal for measurement in extreme dust. cement powder, fly-ash, coal, flour, grain, plastics

■ Benefits
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided quick start wizard for plug and play start-up
• 24 GHz provides superior reflective properties on solids
surfaces
• 100 m (328 ft) range for long-range and difficult applications
• Easy Aimer optimizes signal quality on sloped surfaces
• Programming using infrared Intrinsically Safe handheld
programmer or with SIMATIC PDM or HART handheld device

■ Configuration
Beam angle Mounting unit on vessel Positioning with
Easy Aimer
Installation in
mounting nozzle

4 inch
horn
8° 3 inch
11° horn
(0.39)
10

Note: For best signal, always use largest horn size possible.

SITRANS LR460 installation, dimensions in mm (inch)

4/274 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460

■ Technical specifications
Mode of operation Programming
Measuring principle FMCW radar level measurement Intrinsically Safe Siemens handheld Infrared receiver
programmer (ordered separately)
Frequency 24.2 ... 25.2 GHz FMCW
• Approvals for handheld IS model with ATEX II 1G EEx ia IIC
Measuring range 0.35 ... 100 m (1.15 ... 328.08 ft) programmer T4, CSA/FM Class I, Div. 1,
Groups A, B, C, D T6 at max. ambient
Output temperature of 40 °C (104 °F)
Analog output (HART) Handheld communicator HART Communicator 375
• Signal range Optically isolated
PC SIMATIC PDM
• Load Max. 600 
• Fail-safe mA signal programmable as high, Display (local) Alphanumeric LCD for readout and
low or hold (LOE) entry
Communication HART, optional PROFIBUS PA Power supply 100 ... 230 V AC ± 15 % (50/60 Hz),
6 W (12 VA)
Digital output Relay, NC or NO function,
max. 50 V DC, max. 200 mA, or
rating 5 W 24 V DC +25/-20 %, 6 W (optional)
PROFIBUS PA protocol
Performance (Reference conditions
Layer 1 and 2, Class A, Profile 3.01 Certificates and approvals
General CSAUS/C, CE, FM, RCM
4
according to IEC 60770-1)
Radio European Radio (R&TTE),
• Non-linearity Greater of 25 mm (1 inch) or 0.25 %
Industry Canada, FCC, RCM
of span (including hysteresis and
non-repeatability), over the full ambi- Hazardous Areas CSA/FM Class II, Div. 1,
ent temperature range Groups E, F and G, Class III
• Non-repeatability  10 mm (0.4 inch) ATEX II 1D, 1/2 D, 2D T85 °C
Rated operating conditions INMETRO ExtD A20 IP67 T85 °C
• Amb. temperature for enclosure -40 ... +65 °C (-40 ... +149 °F) GOST Ex DIP A20 Ta 85 °C IP67
• Location Indoor/outdoor
Optional equipment
• Installation category II
• Pollution degree 4 Dust cap PTFE
Medium conditions Air purge connection 1/8" NPT
Dielectric constant r > 1.4
Process temperature range -40 ... +200 °C (-40 ... +392 °F)
Vessel pressure 0.5 bar g (7.25 psi g) maximum
Design
Weight Approx. 6.1 kg (13.4 lb) with 3 inch
universal flange
Materials
• Enclosure Die-cast aluminum, painted
• Degree of protection IP67/Type 4X/NEMA 4X/Type 6/
NEMA 6
• Cable inlet 2x M20x1.5 or ½" NPT
Process connections
• Universal flanges, 304 stainless 3 inch/80 mm, 4 inch/100 mm,
steel, flat faced, with integral Easy 6 inch/150 mm (mates with flange
Aimer EN 1092-1, ASME B16.5, or
JIS B2238 bolt pattern), 0.5 bar g
(7.25 psi g) max. pressure

Siemens FI 01 · 2015 4/275


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR460 7ML5426- Further designs
4-wire, 24 GHz FMCW radar level transmitter with 0 7 7 7 0 - 777 0 Please add "-Z" to Article No. and specify Order
extremely high signal-to-noise ratio and advanced code(s).
signal processing for continuous monitoring of
solids up to 100 m (328 ft). It is ideal for Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
measurement in extreme dust. Measuring-point number/identification
(max. 27 characters); specify in plain text
Order handheld programmer separately
Manufacturer's test certificate: M to DIN 55350, C11
Click on the Article No. for the online configura- Part 18 and to ISO 9000
tion in the PIA Life Cycle Portal.
Operating Instructions Article No.
Process connection
Universal, flat faced, 0.5 bar g (7.25 psi g) English 7ML1998-5JM02
maximum with integral Easy Aimer ball French 7ML1998-5JM11
3 inch (80 mm) A
4 inch (100 mm) B German 7ML1998-5JM32
6 inch (150 mm) C Multi-language Quick Start manual A5E32007360
This device is shipped with the Siemens Milltronics
Antenna
4
manual DVD containing the ATEX Quick Start and
3" horn antenna, fits 80 mm (3 inch) nozzles A Operating Instructions library.
3" horn antenna, fits 80 mm (3 inch) nozzles with B
Accessories
100 mm extension
3" horn antenna, fits 80 mm (3 inch) nozzles with C Handheld programmer, Infra-red, Intrinsically Safe, 7ML5830-2AJ
200 mm extension EEx ia
3" horn antenna, fits 80 mm (3 inch) nozzles with D Dust cap, PTFE, for 3 inch/80 mm horn 7ML1930-1BL
500 mm extension1) Dust cap, PTFE, for 4 inch/100 mm horn 7ML1930-1BM
3" horn antenna, fits 80 mm (3 inch) nozzles with E
1 000 mm extension1) HART modem/USB 7MF4997-1DB
4" horn antenna, fits 100 mm (4 inch) nozzles F (for use with a PC and SIMATIC PDM)

4" horn antenna, fits 100 mm (4 inch) nozzles with G One metallic cable gland M20x1.5, 7ML1930-1AP
100 mm extension rated -40 ... +80 °C (-40 ... +176 °F), HART1)
4" horn antenna, fits 100 mm (4 inch) nozzles with H One metallic cable gland M20x1.5, 7ML1930-1AQ
200 mm extension rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA1)
4" horn antenna, fits 100 mm (4 inch) nozzles with J SITRANS RD100, loop powered display - 7ML5741-...
500 mm extension1) see Chapter 7
4" horn antenna, fits 100 mm (4 inch) nozzles with K SITRANS RD200, universal input display with 7ML5740-...
1 000 mm extension1) Modbus conversion - see Chapter 7
Purge (self-cleaning) connection SITRANS RD300, dual line display with totalizer 7ML5744-...
No purge connection 0 and linearization curve and Modbus conversion -
Purge connection 1 see Chapter 7
Output/Communication SITRANS RD500 web, universal remote monitoring 7ML5750-...
4 ... 20 mA, HART 0 solution for instrumentation - see Chapter 7
PROFIBUS PA 1 For applicable back up point level switch -
see point level measurement section
Power supply/cable inlet
100 ... 230 V AC 1)
Product shipped with plastic cable gland, rated to -20 °C.
• 2 x M20x1.5 A If -40 °C rating required, then metallic cable gland is recommended.
• 2 x ½" NPT B
24 V DC
• 2 x M20x1.5 C
• 2 x ½" NPT D
Approvals
General Purpose, CSAUS/C, Industry Canada, FM, A
FCC, CE and R&TTE, RCM
CSA/FM Class II, Div. 1, Groups E, F, and G, B
Class III
ATEX II 1/2 D T6, CE, R&TTE C
1) Available with Purge option 0 only

4/276 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460

■ Dimensional drawings
SITRANS LR460 (7ML5426)

204 (8.0)

Connection
cover
Electronics
cover

287 (11.29)
Purge connection

Easy Aimer ball locking bolts

Universal slotted flange


Optional horn
extension(s)
Reference
point
4
100/200/
500/1 000
(3.93/7.87/ 228 (8.97)
19.68/39.37) 285 (11.22)

Horn antenna

74.5
(2.93)

97.5 (3.84)

SITRANS LR460, dimensions in mm (inch)

Siemens FI 01 · 2015 4/277


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR460

■ Schematics
AC version DC version Hand programmer

Earth terminal Earth terminal

Cable clamp Cable clamp

4 HART HART SITRANS LR460


Part number:
7ML5830-2AJ

Earth terminal Earth terminal

Cable clamp Cable clamp

PROFIBUS PA PROFIBUS PA

Notes
• Recommended torque on terminal clamping screws, 0.5 ... 0.6 Nm
• 4 ... 20 mA, PROFIBUS PA, DC input circuits, 14 ... 20 AWG, shielded copper wire
• AC input circuit, min. 14 AWG copper wire
• All field wiring must have insulation suitable for at least 250 V
• The equipment must be protected by a 15 A fuse or circuit breaker in the building installation

SITRANS LR460 connections

4/278 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR260/LR460 Specials

■ Selection and ordering data


SITRANS LR260/LR460 Specials SITRANS LR260/LR460 Specials
Article No. Article No.
Process connection Enclosure with electronics (LR460)
part kits - non-pressure-rated
LR260/LR460,100 mm extension for horn antenna, A5E01087872
no purge1)
LR260/LR460, 200 mm extension for horn antenna, A5E01091262
no purge1)
LR260/LR460,100 mm extension for horn antenna A5E01261979
with purge1) LR460 enclosure with board stack, A5E02182085
HART communication, AC power,
LR260/LR460, 200 mm extension for horn antenna A5E01261981 M20 cable inlet, approval option A,
with purge1) no process connection
LR260/LR460, horn 2", no purge, no emitter1) A5E02083905 LR460 enclosure with board stack, A5E02212422

4
LR260/LR460, horn 3", no purge, no emitter1) A5E01623511 PROFIBUS PA communication, AC power,
M20 cable inlet, approval option A,
LR260/LR460, horn 4", no purge, no emitter1) A5E01623512 no process connection
LR260/LR460, horn 2", with purge, no emitter1) A5E02083906 LR460 enclosure with board stack, A5E02212423
HART communication, AC power,
LR260/LR460, horn 3", with purge, no emitter1) A5E01623513 NPT cable inlet, approval option A,
LR260/LR460, horn 4", with purge, no emitter1) A5E01623514 no process connection
LR260/LR460, 3" universal flat faced flange1) A5E02303897 LR460 enclosure with board stack, A5E02212424
PROFIBUS PA communication, AC power,
LR260/LR460, 4" universal flat faced flange1) A5E01259467 NPT cable inlet, approval option A,
LR260/LR460, 6" universal flat faced flange1) A5E01261834 no process connection

LR260/LR460 O-Rings for Easy Aimer1) A5E01261836 LR460 enclosure with board stack, A5E02212425
HART communication, DC power,
Kit, Emitter for LR260/LR4601) A5E02360694 M20 cable inlet, approval option A,
LR260 lid with O-ring A5E02465410 no process connection

Purge conversion kit – non-pressure-rated LR460 enclosure with board stack, A5E02212426
(no flange or extension included) PROFIBUS PA communication, DC power,
M20 cable inlet, approval option A,
LR260/LR460 purge conversion, 2" horn1) A5E02083914 no process connection
LR260/LR460 purge conversion, 3" horn1) A5E02083915 LR460 enclosure with board stack, A5E02212428
HART communication, DC power,
LR260/LR460 purge conversion, 4" horn1) A5E02083916 NPT cable inlet, approval option A,
Enclosure with electronics no process connection
LR460 enclosure with board stack, A5E02212429
PROFIBUS PA communication, DC power,
NPT cable inlet, approval option A,
no process connection
1)
Available with no pressure rating, 0.5 bar g maximum.
Please contact ceg.smpi@siemens.com for special requests.
LR260 enclosure with board stack, A5E02203605
HART communication, M20 cable inlet,
approval option A, no process connection
LR260 enclosure with board stack, A5E02213423
PROFIBUS PA communication,
M20 cable inlet, approval option A,
no process connection
LR260 enclosure with board stack, A5E02165924
HART communication, NPT cable inlet,
approval option A, no process connection
LR260 enclosure with board stack, A5E02213428
PROFIBUS PA communication,
NPT cable inlet, approval option A,
no process connection
Sitrans LR260 enclosure with board stack, A5E03934184
HART communication, NPT cable inlet,
approval option D, no process connection
Sitrans LR260 enclosure with board stack, A5E03934187
HART communication, M20 cable inlet,
approval option E, no process connection
LR260 enclosure with board stack, A5E03934191
HART communication, NPT cable inlet,
approval option F, no process connection
LR260 enclosure with board stack, A5E31820689
PROFIBUS PA communication, M20 cable
inlet, approval option F, no process connection

Siemens FI 01 · 2015 4/279


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560

■ Overview ■ Configuration
Installation

Note:
• Beam angle is the width of the
cone where the energy
density is half of the peak
energy density Emission
• The peak energy density cone
is directly in front of and
in line with the antenna
• There is signal transmitted
outside of the beam angle;
therefore false targets may be
detected 4°

4
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).

■ Benefits
• Rugged stainless steel design for industrial applications
• 78 GHz high frequency provides very narrow beam, virtually
no mounting nozzle noise, and optimal reflection from sloped
solids
• Aimer option to direct beam to area of interest, such as draw
point of cone
• Lens antenna is highly resistant to product build-up
• Air purge connection is included for self-cleaning of
extremely sticky solids
• Local display interface (LDI) allows local programming and
diagnostics Aiming will assist in measuring
material in the cone
■ Application
SITRANS LR560’s plug and play performance is ideal for most
solids applications, including those with extreme dust and high
temperatures to 200 ºC (392 ºF). Unique design allows safe and
simple programming using the Intrinsically Safe handheld pro-
grammer without having to open the instrument’s lid.
SITRANS LR560 includes an optional graphical local display
interface (LDI) that improves setup and operation using an intu-
itive Quick Start Wizard, and echo profile display for diagnostic
support. Start-up is easy using the Quick Start wizard with a few
parameters required for basic operation.
SITRANS LR560 measures practically any solids material to a
range of 100 m (328 ft).
SITRANS LR560 installation, dimensions in mm (inch)
• Key Applications: cement powder, plastic powder/pellets,
grain, coal, wood powder, fly ash

4/280 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560

■ Technical specifications
Mode of operation Power supply
Measuring principle Radar level measurement 4 ... 20 mA/HART Nominal 24 V DC (max. 30 V DC) with
max. 550 
Frequency 78 GHz FMCW
PROFIBUS PA/FOUNDATION Field- 13.5 mA
Minimum detectable distance 400 mm (15.75 inch) from sensor bus 9 ... 32 V DC, per IEC 61158-2
reference point
Certificates and approvals
Maximum measuring range1) • 40 m (131 ft) version
• 100 m (328 ft) version General CSAUS/C, CE, FM
Radio Europe (R&TTE), FCC,
Output Industry Canada, RCM
• Analog output 4 ... 20 mA Hazardous
• Communications • HART • Europe/International IECEx SIR 09.0149X
• Optional: PROFIBUS PA ATEX II 1D, 1/2D, 2D
• Optional: FOUNDATION Fieldbus Ex ta IIIC T139 ºC Da IP68
• Fail-safe • Programmable as high, low or hold ATEX II 3G
(Loss of Echo) Ex nA II T4 Gc
• NE43 programmable Ex nL IIC T4 Gc

4
Performance (according to refer- • US/Canada FM/CSA Class II, Div. 1,
ence conditions IEC60770-1) Groups E, F, G
Class III T4
• Maximum measured error (including 5 mm (0.2 inch) FM/CSA Class I, Div. 2,
hysteresis and non-repeatability)2) Groups A, B, C, D, T4
Rated operating conditions • China NEPSI
(according to reference conditions Ex nA II T4
IEC60770-1) Ex nL IIC T4
DIP A20 TA, T139 ºC, IP68
Installation conditions
• Brazil INMETRO
• Location Indoor/outdoor
BR-Ex nA/nL II T4 IP68
Ambient conditions (enclosure)
Programming
• ambient temperature -40 ... +80 °C (-40 ... +176 °F)
Intrinsically Safe Siemens handheld Infrared receiver
• installation category I
programmer
• pollution degree 4
• Approvals for handheld programmer IS model:
Medium conditions ATEX II 1GD Ex ia IIC T4 Ga
• Dielectric constant r > 1.6 Ex iaD 20 T135 °C
Ta = -20 ... +50 °C
Process temperature and pressure See chart below CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Design Ta = 50 °C
Enclosure Handheld communicator HART communicator 375/475
• Construction 316L/1.4404 stainless steel PC SIMATIC PDM, AMS, PACTware
• Conduit entry M20x1.5, or ½" NPT via adapter Display (local) Graphic local user interface including
• Purge inlet 1/8" NPT, 30 cfm at max. 100 psi quick start wizard and echo profile
• Lens material • 40 m version: PEI displays
• 100 m version: PEEK
1)
From sensor reference point
Damage to lens could result from 2)
continuous purging/cleaning due to Under severe EMI/EMC environments per IEC61326-1 or NAMUR NE21,
abrasive solids. Recommended purg- the device error may increase to a maximum of 25 mm (1 inch)
ing/cleaning only a few seconds 3)
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/
every hour JIS 2220 (10K) bolt hole pattern.
• Degree of protection Type 4X/NEMA 4X, Type 6/NEMA 6,
IP68 with lid closed
• Weight 3.15 kg (6.94 lb) including 3 inch Process temperature and pressure
flange
• Optional local display interface Graphic LCD, with bar graph repre- Version Stainless steel Aimer flange: Aimer flange:
senting level -1 ... 0.5 bar -1 ... 3.0 bar
Process connections 40 m -40 ... +100 °C -40 ... +100 °C -40 ... +100 °C
Universal flat-faced flanges3) (-40 ... +212 °F) (-40 ... +212 °F) (-40 ... +212 °F)
• 3, 4, 6 inch/80, 100, 150 mm,
304 stainless steel 100 m -40 ... +200 °C -40 ... +200 °C -40 ... +120 °C
• 3, 4, 6 inch/80, 100, 150 mm, (-40 ... +392 °F) (-40 ... +392 °F) (-40 ... +248 °F)
316L/1.4404 or 316L/1.4435 stain-
less steel
Aimer flanges3) 3, 4, 6 inch/80, 100, 150 mm, polyure-
thane powder-coated cast aluminum

Siemens FI 01 · 2015 4/281


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560

Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LR560 7ML5440- Further designs
2-wire, 78 GHz FMCW radar level transmitter for 77 7 0 0 - 77 77 Please add "-Z" to Article No. and specify Order
continuous monitoring of solids in silos to a range code(s).
of 100 m (329 ft).
Plug M12 with mating connector1)2)3) ¢ A50
Order handheld programmer separately
Plug 7/8" with mating connector1)3)4) ¢ A55
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal. Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
Measurement and process temperature range (max. 27 characters); specify in plain text
40 m (131 ft) max range, -40 ... +100 °C ¢ 0
100 m (329 ft) max range, -40 ... +200 °C ¢ 1 Manufacturer's test certificate: M to DIN 55350, ¢ C11
Part 18 and to ISO 9000
Process connection
Inspection Certificate Type 3.1 per EN 102044) ¢ C12
Universal flat-faced flange fits ANSI/DIN/JIS
flanges NAMUR NE43 compliant, device preset to failsafe ¢ N07
< 3.6 mA5)
3 inch/80 mm, 304 stainless steel ¢ A
Operating Instructions for HART device Article No.
4 inch/100 mm, 304 stainless steel ¢ B

4 6 inch/150 mm, 304 stainless steel


3 inch/80 mm, 316L stainless steel
¢
¢
C
D
English
German
7ML1998-5KB02
7ML1998-5KB32
4 inch/100 mm, 316L stainless steel ¢ E Multi-language Quick Start manual A5E32052143
6 inch/150 mm, 316L stainless steel ¢ F This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
3 inch/80 mm, painted aluminum, with integral ¢ G Operating Instructions library.
aimer1)
4 inch/100 mm, painted aluminum, with integral ¢ H Operating Instructions for PROFIBUS PA device
aimer1) English 7ML1998-5LT02
6 inch/150 mm, painted aluminum, with integral ¢ J
aimer1) German 7ML1998-5LT32

Enclosure (with cable inlet) Multi-language Quick Start manual A5E32043113


This device is shipped with the Siemens Milltronics
Stainless steel, 1 X ½" NPT ¢ A manual DVD containing the ATEX Quick Start and
Stainless steel, 1 X M20 x 1.5 ¢ B Operating Instructions library.
(plastic gland included)
Operating Instructions for
Pressure rating FOUNDATION Fieldbus device
0.5 bar g (7.5 psi g) maximum ¢ 0
English 7ML1998-5LY02
3 bar g (40 psi g) maximum ¢ 1
German 7ML1998-5LY32
Output/communication
4 ... 20 mA, HART ¢ A Multi-language Quick Start manual A5E32034712
PROFIBUS PA ¢ B This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
FOUNDATION Fieldbus ¢ C Operating Instructions library.
Approvals Accessories
General Purpose, CSAUS/C, Industry Canada, FCC, ¢ A
CE, R&TTE, RCM Hand Programmer, Intrinsically safe 7ML1930-1BK
CSA/FM Class I, Div. 2, Groups A, B, C, D, Class II, ¢ B Local display interface 7ML1930-1FJ
Div.1, Groups E, F, G, Class III
Sun Shield Cover 7ML1930-1FK
ATEX II 1 D, ½ D, 2 D, 3G Ex nA/nL, CE, R&TTE, ¢ C
RCM Housing lid with window 7ML1930-1FL
Local display interface One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 ... +80 °C (-40 ... +176 °F), HART6)
Without LDI (local display interface) ¢ 1
With LDI (local display interface) ¢ 2 One metallic cable gland M20x1.5, 7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA6)
1)
Rated to 120 ºC max. when used with Pressure rating option 1
SITRANS RD100, loop powered display - 7ML5741-...
¢ We can offer shorter delivery times for configurations designated with the see Chapter 7
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1) Available with Approval option A only
2)
Available with Enclosure option B only
3)
Available with Output/communication options B and C only
4)
Available with Pressure rating option 1 only
5)
Available with Output/communication option A only
6) Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.

4/282 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560

■ Options
Handheld programmer Sun shield cover

Part number: Part number:


7ML1930-1BK 7ML1930-1FK

4
SITRANS LR560 handheld programmer and sun shield cover

Siemens FI 01 · 2015 4/283


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560

■ Characteristic curves
Temperature derating curve

Ambient
temperature

90

80

70
Ambient temperature (°C)

60

4
Process 50
temperature

40

30
40 m 100 m
version version
20

10

0
50 100 150 200 250
Process temperature (°C)

SITRANS LR560 temperature derating curve

■ Dimensional drawings
Flat flange 3” aimer flange 4 and 6” aimer flange*

Lid lock

Cable gland Cable gland


Cable gland
176 166.1
Grounding
Grounding lug lug 166.1
Grounding lug (6.93) (6.54) (6.54)
Purge plug Purge plug
Purge plug
Process
connection: Process
Process 3” aimer
connection: connection:
flange 22.3 4 and 6”
flat flange (0.92) A
aimer flange
110 (4.33)
110 110
Sensor 200 (7.87) 9.6
(4.33) 4”: 229 9.6
reference (0.38) (4.33) (0.38)
(9.02)
point 229
6”: 285
(9.02)
(11.22)

10º max.

* C Spanner wrench included 5º max.


A
4” 53.2 (2.09)
29
716
027

6” 60 (2.36)
A5E

SITRANS LR560, dimensions in mm (inch)

4/284 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Radar transmitters
SITRANS LR560 Specials

■ Schematics ■ Selection and ordering data


SITRANS LR560 Specials
Cable gland Article No.
(or NPTcable entry)
LR560 Electronics Modules
LR560 Electronics Module, HART, 100 m range, 7ML1830-3AC
Cable shield (if used) compatible with 7ML54401XX00XAXX,
no enclosure or process connection included.
LR560 Electronics Module, PROFIBUS PA, 7ML1830-3AH
Connect the wires 100 m range, compatible with
to the terminals as 7ML54401XX00XBXX, no enclosure or
shown: the polarity process connection included.
is identified on the
G terminal block. LR560 Electronics Module, FOUNDATION 7ML1830-3AJ
Fieldbus,100 m range, compatible with
7ML54401XX00XCXX, no enclosure or
process connection included.

4
LR560 Electronics Module, HART, 40 m range, 7ML1830-3AK
compatible with 7ML54400XX00XAXX,
no enclosure or process connection included.
Notes: LR560 Electronics Module, PROFIBUS PA, 7ML1830-3AL
1. Depending on the approval rating, glands and plugs may be 40 m range, compatible with
supplied with your instrument. 7ML54400XX00XBXX, no enclosure or
2. DC terminal shall be supplied from a source providing electrical process connection included.
isolation between the input and output, to meet the applicable safety
requirements of IEC 61010-1. LR560 Electronics Module, FOUNDATION 7ML1830-3AM
3. All field wiring must have insulation suitable for rated input voltages. Fieldbus, 40 m range, compatible with
4. Use shielded twisted pair cable (14 ... 22 AWG) for HARTversion. 7ML54400XX00XCXX, no enclosure or
5. Separate cables and conduit may be required to conform to standard process connection included.
instrumentation wiring practices or electrical codes.
LR560 Miscellaneous Spare Kits

SITRANS LR560 connections Kit, Lid Gasket, EPDM, LR560 7ML1830-3AA


Kit, Wrench for 4" and 6" Aimers, LR560 7ML1830-3AB
Kit, O-rings for 3" Aimer, LR560 7ML1830-3AD
Kit, O-rings for 4" Aimer, LR560 7ML1830-3AE
Kit, O-rings for 6" Aimer, LR560 7ML1830-3AF
Kit, Lid Screw and Purge Plug set with 7ML1830-3AG
Hex Keys, LR560
Kit, Lid, No Window, LR560 7ML1830-3AP
Please contact ceg.smpi@siemens.com for special requests.

Siemens FI 01 · 2015 4/285


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters

■ Overview ■ Mode of operation


Introduction Interface Detection
Guided Wave Radar transmitters use TDR (time domain reflec- The SITRANS LG, is a transmitter capable of measuring both an
tometry). upper level and an interface level. The upper liquid must have a
dielectric constant between 1.6 and 10 and the two liquids have
Time Domain Reflectometry (TDR) a difference in dielectric constants greater than 10. A typical
TDR uses pulses of electromagnetic (EM) energy to measure application would be oil over water, with the upper layer of oil
distances or levels. When a pulse reaches a dielectric disconti- being non-conductive with a dielectric constant of approxi-
nuity (created by media surface), part of the energy is reflected. mately 2 and the lower layer of water being very conductive with
The greater the dielectric difference, the greater the amplitude a dielectric constant of approximately 80. This interface
(strength) of the reflection. measurement can only be accomplished when the dielectric
constant of the upper medium is lower than the dielectric con-
The SITRANS LG includes a transmitter and waveguide that has stant of the lower medium.
a characteristic impedance in air and is used as a probe. When
part of the probe is immersed in a material other than air, there is
lower impedance due to the increase in the dielectric. When an
EM pulse is sent down the probe and meets the dielectric
4 discontinuity, a reflection is generated.

24 V DC, 4 ... 20 mA
loop powered
Air: (dk = 1)

Transmit pulse
Upper Low dielectric
Level medium
A reflection develops from the (e.g. oil: dk = 2)
Signal
liquid surface.
Emulsion layer
Air: dK = 1
Interface
Level
Signal High dielectric
medium
A small amount of energy (e.g. water: dk = 80)
continues down the probe in a
low dielectric fluid.

Media dK > 1.4

4/286 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters

■ Application

•Š
•Š

•Š

•ŠP
•ŠP
•ŠP
•ŠP
•ŠP
XGUUUG\GŠz›GO“’ŒGžˆ›Œ™P \WGUUUGXWWGŠz›GO“’ŒG–•Œ P
\GUUUGYWGŠz›GO“’ŒG”ˆŠ•ŒG–“P XWWGUUUG\WWGŠz›GO“’ŒGš ™œ—V”–“ˆššŒšP

YWGUUUG\WGŠz›GO“’ŒGŠ––’•ŽG–“P

[GUUUGYWG”h
V[GUUUGYWG”h

Siemens FI 01 · 2015 4/287


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
Guided wave radar transmitters

Guided Wave Radar (Interface) Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: ( )

4 E-mail: Fax: ( )

Tank/Vessel Information (supply sketch where possible) Sketch Tank dimensions:


attached Height: m/ft
Tank top: Tank bottom: Mounting location: Diameter: m/ft

Open Sloped Top mount Nozzle Length: cm/inch


Flat Flat Thread mount Nozzle Diameter: cm/inch
Conical Conical Flange mount Process connection type:
Parabolic Parabolic Bypass/Sidepipe Mount Process connection size:
Pipe mount Distance to sidewall: cm/inch
Pressure:
Displacer replacement
Normal: (please supply drawings)

Maximum (relief):

Interface Data
Upper material: Lower material: Emulsion layer: Yes
Upper material thickness: cm/inch Lower material thickness: cm/inch No (preferred)
Upper material dielectric: Lower material dielectric: Emulsion thickness: cm/inch

Material
Material being measured: Liquid Slurry
Material temperature: Norm: °C/°F Max: °C/°F

Coating buildup: Yes No Turbulence: Yes No


3
Maximum Viscosity: Density: kg/m
Kinematic Viscosity (cSt) = Dynamic Viscosity (cP) / Density (kg/m )
3 Upper
Emulsion material
1 ... 5 cSt (like water) 50 ... 100 cSt (like honey) layer
Lower
5 ... 20 cSt (like machine oil) 100 ... 500 cSt (like syrup/molasses) material
20 ... 50 cSt (like cooking oil) >500 cSt (like tar)

Installation
Power available: Outputs required: 4 ...20 mA
Communications: HART/ 4 ... 20 mA Other (please specify)

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-938R0

4/288 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

■ Overview ■ Configuration
Mounting on nozzle

Flange Metal sheet

Installation in non-metal vessel

4
The guided microwave principle requires a metal surface on the
process fitting. Therefore, use in plastic vessels etc. an instrument
version with flange (from DN 50) or place a metal sheet, Ø > 200 mm
(8 inch), beneath the process fitting when screwing it in.
The Siemens SITRANS LG series are guided wave radar trans- Make sure that the plate has direct contact with the process fitting
mitters for level, level/interface, and volume measurement of
Mounting socket
liquids and solids. The Sitrans LG product line can handle If possible, avoid sockets, mount the sensor
changes in process conditions, high temperatures and pres- flush with the vessel top. If this is not possible,
sures, and steam. use short sockets with small diameter.
Higher sockets or sockets with a bigger

■ Benefits diameter can generally be used. They simply


increase the upper blocking distance. Check if
• High accuracy to ± 2 mm this is relevant for your measurement.
h)
In such cases, always carry out a false signal
• Advanced Diagnostics available for high degree of safety suppression after installation.
• Simple menu driven display offers ease of setup
d)
• Large range of options offers reliability in most continuous Socket must
measurement applications be
d h installed flush
• Ease of maintenance through module design and field
replaceable and adjustable probe options DN 40 ... DN 150 < 150

• Perfect solution for wide range of applications from storage to > DN 150 ... DN 200 < 100
interface with options for extreme pressure and temperature
conditions
• Universally applicable in liquids, interface, slurries and solids
• Highly immune to buildup
• Wide range of Hygienic options

■ Application When welding the socket, make sure that the socket is flush to the
The SITRANS LG series comes in four different models, depend- vessel top.
ing on the applications, level of performance, and functionality Before beginning the welding work, remove the electronics module
from the sensor. By doing this, you avoid damage to the electronics
required:
through inductive coupling.
• SITRANS LG240 offers configuration options for your hygienic
and corrosive application requirements
• SITRANS LG250 Highly flexible solution for liquid level and
interface applications. Extremely versatile offering solutions
for storage, separation of materials or difficult ammonia appli- Inflowing medium
cations Do not mount the instruments in
• SITRANS LG260 Ideal for measuring level in medium range or above the filling stream. Make
solids applications including; grains, plastics, and cement sure that you detect the product
surface, not the inflowing product.
• SITRANS LG270 offers configuration options for extreme
conditions including high temperature and high pressure
applications such as: harsh applications found in chemical,
HPI and energy industries for example, LPG gas tanks, steam
boilers and distillation columns

SITRANS LG Series installation

Siemens FI 01 · 2015 4/289


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

■ Technical specifications
Mode of operation Design
Measuring principle Guided wave radar measurement Instrument weight (dependent on Approx. 0.8 ... 8 kg
process fitting) - see manual for (0.176 ... 17.64 lb)
Measuring range 300 ... 75 000 mm further details
(11.81 ... 2 952.75 inch)
Materials
Output
• Enclosure • Plastic housing plastic PBT
mA analog output with 4 ... 20 mA/HART (SIL optional) (Polyester)
HART digital signal • Aluminum die-casting housing,
Output range aluminum die-casting AISi10 mg,
powder-coated- basis: polyester
• Analog Current: minimum 3.8 mA,
• Stainless steel housing, precision
maximum 20.5 mA
casting 316L
• Start-up current  10 mA for 5 ms after switching on, • Stainless steel housing, electropol-
 3.6 mA ished 316L
Diagnostic alarm Failure signal current output (adjust- • Degree of protection • Type 4/NEMA 4, IP65
able): last valid measured value, • Plastic housing IP66/IP67
 21 mA,  3.6 mA • Aluminum and stainless steel

4 Digital communication HART Version 7 x and multidrop com-


patible • Cable inlet
housings are IP66/68
2x M20x1.5 or 2 x ½" NPT
Modbus Modbus RTU, Modbus ASCII, Process connections
Levelmaster
• Pipe thread, cylindrical (ISO 228 T1) G¾" A, G1" A, G1½" A according to
PROFIBUS PA DIN 3852-A
Performance Process reference conditions accord- • American pipe thread, conical ¾" NPT, 1" NPT, 1½" NPT
ing to DIN EN 61298-1 (ASME B1.20.1)
Non-linearity • Flanged DIN from DN 25, ANSI from 1"
• Coaxial
• Hygienic Hygienic fittings
• Single rod probes
Programming
• Interface models See manual for more details
Local Four button, menu-driven data entry
Resolution and repeatability Accuracy ± 2 mm (0.08 inch)
Handheld communicator Hart communicator
Accuracy
PC SIMATIC PDM, AMS, PACTware
• Coaxial/rod/cable probes ± 2 mm (0.08 inch)
Power
• Interface models ± 5 mm (0.197 inch)
2 wire Hart version 9.6 ... 35 V DC
(Note: Typical deviation,
Interface measurement) 4 wire versions 9.6 … 48 V DC, 20 … 42 V AC,
50/60 Hz and 90 … 253 V AC,
See manual for more details
50/60 Hz
Electromagnetic compatibility
Modbus 8 … 30 V DC
(check if needed)
PROFIBUS PA 9 … 32 V DC
• Measuring cycle time < 500 ms
Note: see manual for specific power
• Step response time 3s
based on ordered options
• Temperature Effects The measurement error from the
Certificates and approvals
process conditions is in the specified
pressure and temperature range of Hazardous approvals: ATEX, FM, CSA, IECex
below 1 %
Hygienic approvals EHEDG
Rated operating conditions
Overfill protection WHG
• Ambient temperature for enclosure -40 ... +80 °C (-40 ... +176 °F)
Ship approval ABS, CCS, GL
• LCD readable temperature range -40 ... +80 °C (-40 ... +176 °F) with
display heated option
• Location Indoor/outdoor
• Installation category II
• Pollution degree 2
• Relative Humidity 20 ... 85 %
Medium conditions
Dielectric constant dK  1.4 (configuration dependent)
Note: for measurement below 1.4 use
probe end tracking.
Process temperature range -196 ... +450 °C (-321 ... +842 °F)
Vessel pressure -1 … +400 bar
(-100 … +40 000 kPa)

4/290 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
SITRANS LG240 SITRANS LG250 SITRANS LG260 SITRANS LG270
Industries Food, Beverage and Chemical/HPI/Power/General Cement, power generation, Chemical/HPI/Power/General
Pharmaceutical food, processing,
mineral processing, mining
Applications Hygienic and corrosive Liquids, storage and process Cement, fly ash, grain, coal, Aggressive applications in
applications vessels with agitators, flour, plastics Liquids, storage and process
vaporous liquids, interface vessels with agitators,
vaporous liquids, high
temperatures and pressures,
low dielectric media
Range 32 m 75 m 60 m 60 m
Performance ± 2 mm ± 2 mm ± 2 mm ± 2 mm
Temperature -40 ... +150 °C -40 ... +200 °C -40 ... +200 °C -196 ... +450 °C
(-40 ... +302 °F) (-40 ... +392 °F) (-40 ... +392 °F) (-320.8 ... +842 °F)
Communications • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART • 4 ... 20 mA/HART
• Modbus, Modbus RTU, • Modbus, Modbus RTU, • Modbus, Modbus RTU, • Modbus, Modbus RTU,
Modbus ASCII, Levelmaster Modbus ASCII, Levelmaster Modbus ASCII, Levelmaster Modbus ASCII, Levelmaster
• PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
• SIMATIC PDM
• DTM/FDT for PACTware
• Fieldcare
4

Siemens FI 01 · 2015 4/291


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG240 7ML5880- SITRANS LG240 7ML5880-
Guided Wave Radar sensor for Hygienic and 77777 - 7777 777 Guided Wave Radar sensor for Hygienic and 77777 - 7777 777
corrosive continuous level and interface corrosive continuous level and interface
measurement of liquids. measurement of liquids.
Click on the Article No. for the online con- Bolting DN 50, PN 25 DIN11851/ 14
figuration in the PIA Life Cycle Portal. PTFE-TFM 1600
Approvals Bolting DN 65, PN 25 DIN11851/ 15
PTFE-TFM 1600
Ordinary location CE9) 0A
Flange DN 25, PN 40 Form C, DIN 2501/ 20
ATEX II 1G, 1/2G, 2G Ex ia IIC T69) 0E PTFE-TFM 1600
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 0H
1/2D, 1/3D, 2D, Ex t IIIC IP66 T11)13)15)24) Flange DN 40, PN 40 Form C, DIN 2501/ 21
0J PTFE-TFM 1600
ATEX II 1/2G, 2G Ex d ia IIC T61)12) Flange DN 50, PN 40 Form C, DIN 2501/ 22
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D, 0K PTFE-TFM 1600
2D IP6x1)11)12)13)15)24) Flange DN 50, PN 40 Form V13, DIN 2513/ 23
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC 0N PTFE-TFM 1600
IP66 T11)13)15)24)
4 IEC Ex ia IIC T69) 0P
Flange DN 65, PN 40 Form C, DIN 2513/
PTFE-TFM 1600
24

IEC Ex ia IIC T6 + IEC IP6x T tD11)13)15)24) 0Q Flange DN 80, PN 40 Form C, DIN 2501/ 25
IEC Ex d ia IIC T61)12) 0R PTFE-TFM 1600
IEC Ex d ia IIC T6 + IEC IP6x 0S Flange DN 100, PN 16 Form C, DIN 2501/ 26
T tD1)11)12)13)15)24) PTFE-TFM 1600
FM (NI) Class I, Div. 2, Groups A, B, C, D 1A Flange DN 80, PN 40 EN1092-1 Form B1/ 27
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1B PTFE-TFM 1600
D, E, F Flange DN 100, PN 40 EN1092-1 Form B1/ 28
PTFE-TFM 1600
FM(XP-IS) Class I, II, III, Div. 1, Groups A, B, 1C
C, D, E, F, G1)12) Flange 2" 150 lb RF, ANSI B16.5/ 30
PTFE-TFM 1600
CSA (NI) Class I, Div. 2, Groups A, B, C ,D 1E
(DIP) Class II, III, Div. 1, Groups E, F, G11)13)15) Flange 2" 300 lb RF, ANSI B16.5/ 31
PTFE-TFM 1600
CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1F
C,D, E, F, G Flange 3" 150 lb RF, ANSI B16.5/ 32
PTFE-TFM 1600
CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1G
B, C, D, E, F, G1)12) Flange 4" 150 lb RF, ANSI B16.5/ 33
PTFE-TFM 1600
Probe version/Material
Electronics
Probe cable ø4 mm (0.16 inch) with gravity A
weight/PFA2)7) Two-wire 4 ... 20mA/HART 0
Probe exchangeable rod (ø8 mm) / 1.4435 B Four-wire Modbus19)20)21)22) 1
(BN2), can be autoclaved (Ra < 0.76 µm)3)7) Two-wire 4...20mA/HART with SIL 2
Probe exchangeable rod (ø8 mm) / 1.4435 C qualification17)18)
(BN2), (Ra < 0.76 µm)3)7) Four-wire 4...20mA/HART; 90...253V AC; 3
Probe rod ø10 mm (0.39 inch)/PFA2)7) D 50/60 Hz1)8)10)
Four-wire 4...20mA/HART; 9.6...48V DC; 4
Process fitting/Material 20...42 V AC1)8)10)
Clamp 2" PN 16 (ø64 mm) DIN 32676, 00 PROFIBUS PA 5
ISO 2852/1.4435 (BN2)4) Seal/Process temperature
Clamp 2" PN 16 (ø64 mm) DIN 32676, 01
ISO 2852/PTFE-TFM 1600 Without glass seal/-40 ... +150 °C A
Clamp 2½" PN 10 (ø77.5 mm) DIN 32676, 02 (-40 ... +302 °F)5)11)
ISO2852/1.4435 (BN2)4) FFKM (Kalrez 6221)/-20...150 °C B
(-4... +302 °F)
Clamp 2½" PN 10 (ø77.5 mm) DIN 32676, 03 EPDM (Freudenberg 70 EPDM 291)/ C
ISO 2852/PTFE-TFM 1600 -20...130 °C (-4 ... +266 °F)
Clamp 3" PN 10 (ø91 mm) DIN 32676, 04
ISO 2852/1.4435 (BN2)4) Housing/Protection/Cable
Clamp 3" PN 10 (ø91 mm) DIN 32676, 05 Plastic IP66/IP67 M20x1.5/blind stopper A
ISO 2852/PTFE-TFM 1600 Plastic IP66/IP67 ½" NPT/blind stopper B
Clamp 4" PN6 (ø119 mm) DIN 32676, 06 Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ C
ISO 2852/1.4435(BN2)4) blind stopper
Clamp 4" PN6 (ø119 mm) DIN 32676, 07 Aluminium/IP66/IP68 (0.2 bar) ½" NPT/ D
ISO 2852/PTFE-TFM 1600 blind stopper
Bolting DN 32, PN 40 DIN11851/ 08 Aluminium double chamber/IP66/IP68 E
1.4435(BN2)4) (0.2 bar) M20x1.5/blind stopper
Bolting DN 32, PN 40 DIN11851/ 10 Aluminium double chamber/IP66/IP68 F
PTFE-TFM 1600 (0.2 bar) ½" NPT/blind stopper
Bolting DN 40, PN 40 DIN11851/ 11 Stainless steel (precision casting) 316L/ G
1.4435 (BN2)4) IP66/IP68 (0.2 bar) M20x1.5/blind stopper
Bolting DN 40, PN 40 DIN11851/ 12 Stainless steel (precision casting) 316L/ H
PTFE-TFM 1600 IP66/IP68 (0.2 bar) ½" NPT/blind stopper
Bolting DN 50, PN 25 DIN11851/ 13 Stainless steel (electropolished) 316L/ J
1.4435(BN2)4) IP66/IP68 (0.2 bar) M20x1.5/blind stopper

4/292 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG240 7ML5880- SITRANS LG240 7ML5880-
Guided Wave Radar sensor for Hygienic and 77777 - 7777 777 Guided Wave Radar sensor for Hygienic and 77777 - 7777 777
corrosive continuous level and interface corrosive continuous level and interface
measurement of liquids. measurement of liquids.
Stainless steel (electropolished) 316L/IP66/ K Further designs (mandatory) Order Code
IP68 (0.2 bar) ½" NPT/blind stopper
Please add "-Z" to Article No. and specify
Stainless steel double chamber/IP66/IP68 L Order code(s).
(0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/IP68 M Supplementary electronics
(0.2 bar) ½" NPT/blind stopper Without A00
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ N Additional current output 4 ... 20 mA1)23) A01
cable gland stainless steel Local display interface
Aluminium double chamber/IP66/IP68 P Without E00
(0.2 bar) M20x1.5/cable gland stainless steel Mounted E01
Stainless steel (precision casting) 316L/IP66/ Q Laterally mounted1) E02
IP68 (0.2 bar) M20x1.5/Cable gland stainless
Language of display
4
steel
Stainless steel (electropolished) 316L/IP66/ R German L00
IP68 (0.2 bar) M20x1.5/cable gland stainless English L01
steel French L02
Aluminium single chamber / IP66/IP68 W Dutch L03
(0.2 bar) M20x1.5 / Cable gland brass Italian L04
nickel-plated
Spanish L05
Aluminium double chamber / IP66/IP68 X Portuguese L06
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated Russian L07
Stainless steel single chamber (precision Y Chinese L08
casting) / IP66/IP68 (0.2 bar) M20x1.5 / Japanese L09
Cable gland brass nickel-plated Operating instructions
Lengths German M00
Rod ø8 mm (0.31 inch)/1.4435 English M01
(Basle standard 300 ... 4 000 mm) French M02
Spanish M03
300 ... 1 000 mm (11.81 ... 39.37 inch)14) 0
1 001 ... 2 000 mm (39.41 ... 78.74 inch)14) 1
2 001 ... 3 000 mm (78.78 ... 118.11 inch)14) 2 Selection and Ordering data Order code
3 001 ... 4 000 mm 3
(118.15 ... 157.48 inch)14) Further designs (optional)

Rod ø10 mm (0.24 inch)/PFA Please add "-Z" to Article No. and specify Order
(300 ... 4 000 mm) code(s).

300 mm (11.81 inch)14) 9 R1A Enter the total insertion length in plain text descrip- Y01
tion
500 mm (19.69 inch)14) 9 R1B
300 ... 1 000 mm (11.81 ... 39.37 inch)14) 9 R1C Enter the total length of rigid part (cable version Y02
only)
1 001 ... 5 000 mm (39.41 ... 78.74 inch)14) 9 R1D
Cleaning included certificate: oil, grease and sili- W01
2 001 ... 3 000 mm (78.78 ... 118.11 inch)14) 9 R1E cone free
3 001 ... 4 000 mm 9 R1F
(118.15 ... 157.48 inch)14) Identification Label (measurement loop) stainless Y17
steel
Cable ø4 mm (0.16 inch)/PFA
(500 ... 32 000 mm) Identification Label (measurement loop) Foil Y18

500 mm (9.69 inch) 9 R1G 3.1 Certificate instrument16) C12


501 ... 1 000 mm (19.72 ... 39.37 inch) 9 R1H 3.1 Certificate material (NACE0175)16) D07
1 001 ... 2 000 mm (39.37 ... 196.85 inch) 9 R1 J 3.1 Certificate instrument with test data16) C25
2 001 ... 4 000 mm (196.89 ... 393.70 inch) 9 R1K 2.2 Certificate material16) C15
4 001 ... 5 000 mm (393.74 ... 590.55 inch) 9 R1L
5 001 ... 10 000 mm (590.59 ... 787.40 inch) 9 R1M Quality/test plan16) C26

10 001 ... 15 000 mm (787.44 ... 984.25 inch) 9 R1N Dye penetration test + 3.1 certificate/instrument16) C13
15 001 ... 20 000 mm 9 R1P X-ray test + 3.1 certificate/instrument16) C14
(984.29 ... 1 181.10 inch)
Positive material identification test + 3.1 certificate/ C16
20 001 ... 25 000 mm 9 R1Q instrument16)
(1 181.14 ... 1 377.95 inch) Roughness test + 3.1 certificate/instrument16) C18
25 001 ... 32 000 mm 9 R1R
(1 377.99 ... 1 574.80 inch) Pressure test + 3.1 certificate/instrument16) C31
Helium leak test + 3.1 certificate/instrument16) C32
Ferrite measuring accuracy to DIN32514-1 + 3.1 C60
certificate/instrument16)
Pressure test according to Norsok + 3.1 certificate/ C61
instrument16)
5 point calibration certificate + 3.1 certificate/ C62
instrument16)

Siemens FI 01 · 2015 4/293


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Selection and Ordering data Article No.
Additional Operating Instructions Accessories
German Sitrans LG, GWR sensor Display Module A5E34143449
4 … 20 mA/HART - two-wire, PFA insulated PBD-51041000 SITRANS RD100, loop powered display - 7ML5741-...
4 … 20 mA/HART - two-wire, Polished version PBD-51041001 see Chapter 7

4 … 20 mA/HART - four-wire PFA insulated PBD-51041002 SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
4 … 20 mA/HART - four-wire Polished version PBD-51041003
SITRANS RD300, dual line display with totalizer 7ML5744-...
Modbus- PFA insulated PBD-51041004 and linearization curve and Modbus conversion -
Modbus protocol, Polished version PBD-51041005 see Chapter 7
PROFIBUS PA, PFA insulated PBD-51041006 SITRANS RD500 web, universal remote monitoring 7ML5750-...
PROFIBUS PA, polished version PBD-51041007 solution for instrumentation - see Chapter 7

English For applicable back up point level switch -


see point level measurement section
4 … 20 mA/HART - two-wire PFA insulated PBD-51041037
1)

4
Available with Housing/Protection/Cable options E,F, L, M only
4 … 20 mA/HART - two-wire Polished version PBD-51041038 2)
Available only with PFA Process Fitting/Material including options 01, 03,
4 … 20 mA/HART - four-wire PFA insulated PBD-51041039 05, 07, 10, 12, 14 ... 33 (PTFE-TFM 1600 options)
3)
4 … 20 mA/HART - four-wire Polished version PBD-51041040 Available only with Process Fitting/Material options 00, 02, 04, 06, 08, 11,
and 13 [1.4435 (BN2) options]
Modbus- PFA insulated PBD-51041041 4)
Available with Length options 0, 1, 2, 3 only (Rod ø8 mm 1.4435 options)
Modbus protocol, Polished version PBD-51041042 5)
Available with Length options R1A ... R1R only (Rod ø10 mm/PFA and
PROFIBUS PA, PFA insulated PBD-51041043 Cable ø4 mm/PFA options)
7)
Available only with the same rod or cable diameter in Length options
PROFIBUS PA, polished version PBD-51041044 8)
Available with Supplementary electronic option A00 and Indicating/Adjust-
French ment modules E00, E01
9)
4 … 20 mA/HART - two-wire PFA insulated PBD-51041111 Available with Supplementary electronic option A01 approval options
0A,0E, and 0P
4 … 20 mA/HART - two-wire Polished version PBD-51041112 10)
Available with Approval options 0A,0J,0K,0N,0R,OS,1A,1C,1E,1F, and 1G
4 … 20 mA/HART - four-wire PFA insulated PBD-51041113 11)
Available with Version/Material options A and D only
12)
4 … 20 mA/HART - four-wire Polished version PBD-51041114 Available with Indicating/adjustment modules E00 and E01
13)
Modbus- PFA insulated PBD-51041115 Available with Seal/Process temperature C only
14)
Not available with Y02
Modbus protocol, Polished version PBD-51041116 15)
Available with Housing/Protection options C, D, E, F, G, H, L, M
PROFIBUS PA, PFA insulated PBD-51041117 16)
Listed Certificates are not available with all configurations, please contact
PROFIBUS PA, polished version PBD-51041118 factory for more information
17)
SIL electronic option 2 available with Approval options 0A, 0E, 0H, 0N, 0P,
Spanish 0Q, 1A, 1B, 1E and 1F
4 … 20 mA/HART - two-wire PFA insulated PBD-51041074 18)
Available with Supplementary electronic option A00, SIL electronics
19)
4 … 20 mA/HART - two-wire Polished version PBD-51041075 Modbus only available with Approval options GP and NI and XP-IS/Ex d ia
20)
4 … 20 mA/HART - four-wire PFA insulated PBD-51041076 Modbus only available with two chamber housing options
21)
Modbus not available with Supplementary electronic (only for HART)
4 … 20 mA/HART - four-wire Polished version PBD-51041077 option
22)
Modbus- PFA insulated PBD-51041078 Modbus not available with lateral mount display option
23)
Modbus protocol, Polished version PBD-51041079 Not available with indicating/adjustment module E02
24)
Available with Housing/protection options D, F, H and M
PROFIBUS PA, PFA insulated PBD-51041080
PROFIBUS PA, polished version PBD-51041081

4/294 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG250 7ML5881- SITRANS LG250 7ML5881-
A guided wave radar sensor for continuous 77777 - 7777 777 A guided wave radar sensor for continuous 77777 - 7777 777
level and interface measurement of liquids. level and interface measurement of liquids.
Click on the Article No. for the online con- Process fitting/Material
figuration in the PIA Life Cycle Portal.
Thread G¾" (DIN 3852-A) PN 6/316L 00
Approvals Thread ¾" NPT (ASME B1.20.1) PN 6/316L 01
Ordinary location CE16) 0A Thread G¾" (DIN 3852-A) PN 40/316L 02
Shipping approval19)28)29) 0B
Thread ¾" NPT (ASME B1.20.1) PN 40/316L 03
ATEX II 1G, 1/2G, 2G Ex ia IIC T616) 0E
Thread G¾" (DIN 3852-A) PN 100/316L 04
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping 0G Thread ¾" NPT (ASME B1.20.1) PN 100/316L 05
approval GL19)28)29)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 0H Thread G1" (DIN 3852-A) PN 40/316L 06
1/2D, 1/3D, 2D, Ex t IIIC IP6616)23)40) Thread 1" NPT (ASME B1.20.1) PN 40/316L 07
ATEX II 1/2G, 2G Ex d ia IIC T61)21) 0J Thread G1" (DIN 3852-A) PN 100/316L 08
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1D, 0K Thread 1" NPT (ASME B1.20.1) PN 100/316L 10
1/2D, 1/3D, 2D, Ex t IIIC IP66 T1)21)23)40)
ATEX II 1/2G, 2G Ex d IIC T614)20) 0L
Thread G1½" (DIN 3852-A) PN 40/316L
Thread 1½" NPT (ASME B1.20.1) PN 40/316L
11
12 4
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D, 0M Thread G1½" (DIN 3852-A) PN1 00/316L 13
1/3D, 2D, Ex t IIIC IP66 T 14)20)23)40)
Thread 1½" NPT (ASME B1.20.1) PN 100/316L 14
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 0N Thread 2 NPT PN 40, ASME B1.20.1/316L37)38) 15
T20)23)40)
IEC Ex ia IIC 16) 0P Flange DN 25 PN 40 Form C, DIN 2501/316L 20
IEC Ex ia IIC T6 + IEC IP6x T tD16)20)23)40) 0Q Flange DN 25 PN 40 Form F, DIN 2501/316L 21
Flange DN 40 PN 40 Form C, DIN 2501/316L 22
IEC Ex d ia IIC T61)21)23)40) 0R
IEC Ex d ia IIC T6 + IEC IP6x T tD1)20)21)40) 0S Flange DN 50 PN 40 Form C, DIN 2501/316L 23
IEC Ex d IIC T614)20) 0T Flange DN 50 PN 40 form V13, DIN 2513/316L 24
Flange DN 80 PN 40 Form C, DIN 2501/316L 25
IEC Ex d IIC T6 + IEC IP6x T tD14)20)23)40) 0U
FM (NI) Class I, Div. 2, Groups A, B, C, D 1A Flange DN 80 PN 40 Form V13, DIN 2501/316L 26
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1B Flange DN 100 PN 16 Form C, DIN 2501/316L 27
D, E, F Flange DN 100 PN 16 Form C, DIN 2501/316L 28
FM(XP-IS) Class I, II, III, Div. 1, Groups A, B, 1C Flange DN 100PN 40 Form C, DIN 2501/316L 30
C, D, E, F, G1)21) Flange DN 100 PN 40 Form V13, DIN 2513/316L 31
FM (XP) Class I, Div. 1, Groups A, B, C, D20) 1D Flange DN 150 PN 16 Form C, DIN 2501/316L 32
CSA (NI) Class I, Div. 2, Groups A, B, C ,D 1E Flange DN 50 PN 40 EN1092-1 Form B1/316L 33
(DIP) Class II, III, Div. 1, Groups E, F, G
Flange DN 80 PN 40 EN1092-1 Form B1/316L 34
CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1F Flange 1" 150 lb RF, ANSI B16.5/316L 35
C,D, E, F, G
CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1G Flange 1½" 150 lb RF, ANSI B16.5/316L 36
B, C, D, E, F, G1)21) Flange 2" 150 lb RF, ANSI B16.5/316L 37
CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1H Flange 2" 300 lb RF, ANSI B16.5/316L 38
C, D, E, F, G14)20) Flange 3" 150 lb RF, ANSI B16.5/316L 40
Probe version/Material Flange 3" 300 lb RF, ANSI B16.5/316L 41
Probe exchangeable cable ø2 mm A Flange 4" 150 lb RF, ANSI B16.5/316L 42
(0.08 inch) with gravity weight/316L8)9)11)26) Flange 4" 300 lb RF, ANSI B16.5/316L 43
Probe exchangeable cable ø2 mm B Flange 6" 150 lb RF, ANSI B16.5/316L 44
(0.08 inch) center weight/316L8)9)12)26) Flange 6" 300lb RF, ANSI B16.5/316L 45
Probe exchangeable cable ø4 mm C
(0.16 inch) with gravity weight/316L8)9)11)26) Electronics
Two-wire 4 ... 20mA/HART 0
Probe exchangeable cable ø4 mm D
(0.16 inch) with center weight/316L8)9)12)26) Four-wire Modbus33)34)35)36) 1
Probe exchangeable rod E Two-wire 4...20mA/HART with SIL 2
ø8 mm (0.31 inch)/316L2)8)10)11)26) qualification24)32)
Probe exchangeable rod F Four-wire 4...20mA/HART; 90...253V AC; 50/ 3
ø12 mm (0.47 inch)/316L3)8)10)11)24)26) 60Hz1)15)17)
Four-wire 4...20mA/HART; 9.6...48V DC; 4
Probe coax version ø21.3 mm (0.84 inch) G 20...42V AC1)15)17)
with single hole/316L8)9)11)26)27) PROFIBUS PA 5
Probe coax version ø21.3 mm (0.84 inch) H
with multiple hole/316L8)9)11)26)27)
Probe coax version ø21.3 mm (0.84 inch) J
for Ammonia application/316L4)8)9)11)25)31)
Probe coax version ø42.2 mm (1.66 inch) K
with multiple hole/316L 5)8)9)11)24)26)27)

Siemens FI 01 · 2015 4/295


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG250 7ML5881- SITRANS LG250 7ML5881-
A guided wave radar sensor for continuous 77777 - 7777 777 A guided wave radar sensor for continuous 77777 - 7777 777
level and interface measurement of liquids. level and interface measurement of liquids.
Seal/Second line of defense/ Aluminium double chamber / IP66/IP68 X
Process temperature (0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
FKM (SHS FPM 70C3 GLT)/without glass seal/ A
-40 ... +80 °C (-40 ... +176 °F)6) Stainless steel single chamber (precision Y
casting) / IP66/IP68 (0.2 bar) M20x1.5/
FKM (SHS FPM 70C3 GLT)/without glass seal/ B Cable gland brass nickel-plated
-40 ... +150 °C (-40 ... +302 °F)
FFKM (Kalrez 6375)/with glass seal/ C Lengths
-20 ... +200 °C (-4 ... +392 °F) Rod ø8 mm/316L
EPDM (A+P 75.5/KW75F)/without glass seal/ D 300 ... 1 000 mm (11.81 ... 39.37 inch)22) 0
-40 ... +80 °C (-40 ... +176 °F)
1 001 ... 2 000 mm (39.41 ... 78.74 inch)22) 1
EPDM (A+P 75.5/KW75F)/with glass seal/ E
-40 ... +150 °C (-40 ... +302 °F) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)22) 2
FFKM (Kalrez 6375)/with glass seal/ F 3 001 ... 4 000 mm (118.15 ... 157.48 inch)22) 3
4 -20 ... +200 °C (-4 ... +392 °F)
EPDM (A+P 75.5/KW75F)/without glass seal/ G
4 001 ... 5 000 mm (157.52 ... 196.85 inch)22)
5 001 ... 6 000 mm (196.89 ... 236.22 inch)22)
4
5
-40 ... +80°C (-40 ... +176 °F)6) Rod ø12 mm/316L
EPDM (A+P 75.5/KW75F)/without glass seal/ H
-40 ... +150 °C (-40 ... +302 °F) 300 ... 1 000 mm (11.81 ... 39.37 inch)22) 9 R2A
EPDM (A+P 75.5/KW75F)/with glass seal/ J 1 001 ... 2 000 mm (39.41 ... 196.85 inch)22) 9 R2B
-40 ... +150 °C (-40 ... +302 °F) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)22) 9 R2C
Silicone FEP coated (A+P FEP-O-SEAL)/with- K 3 001 ... 4 000 mm (118.15 ... 157.48 inch)22) 9 R2D
out glass seal/ -40 ... +80 °C (-40 ... +176 °F)6)
Cable lengths ø2 or 4 mm/316L
Silicone FEP coated (A+P FEP-O-SEAL)/with- L
501 ... 1 000 mm (19.72 ... 39.37 inch) 9 R2E
out glass seal/-40 ... +150 °C (-40 ... +302 °F)
Silicone FEP coated (A+P FEP-O-SEAL)/with M 1 000 ... 5 000 mm (39.37 ... 196.85 inch) 9 R2F
glass seal/-40 ... +150 °C (-40 ... +302 °F) 5 001 ... 10 000 mm (196.89 ... 393.70 inch) 9 R2G
With borosilicate glass lead through/with glass N 10 001 ... 15 000 mm (393.74 ... 590.55 inch) 9 R2H
seal/-60 ... +150 °C (-76 ... +302 °F)7) 15 001 ... 20 000 mm (590.59 ... 787.40 inch) 9 R2J
FFKM (Kalrez 6375)/without glass seal/ P 20 001 ... 25 000 mm (787.44 ... 984.25 inch) 9 R2K
-20 … +200 °C
25 001 ... 30 000 mm (984.29 ... 1 181.10 inch) 9 R2L
FKM (SHS FPM 70C3 GLT)/with glass seal/ Q
-40 ... 80 °C6) 30 001 ... 35 000 mm 9 R2M
(1 181.14 ... 1 377.95 inch)
Housing/Protection/Cable
35 001 ... 40 000 mm 9 R2N
Plastic IP66/IP67 M20x1.5/blind stopper A (1 377.99 ... 1 574.80 inch)
Plastic IP66/IP67 ½" NPT/blind stopper B 40 001 ... 45 000 mm 9 R2P
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ C (1 574.84 ... 1 771.65 inch)
blind stopper 45 001 ... 50 000 mm 9 R2Q
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/blind D (1 771.69 ... 1 968.50 inch)
stopper 50 001 ... 55 000 mm 9 R2R
Aluminium double chamber/IP66/IP68 E (1 968.54 ... 2 165.35 inch)
(0.2 bar) M20x1.5/blind stopper 55 001 ... 60 000 mm 9 R2S
Aluminium double chamber/IP66/IP68 F (2 165.39 ... 2 362.20 inch)
(0.2 bar) ½" NPT/blind stopper 60 001 ... 65 000 mm 9 R2T
Stainless steel (precision casting) 316L/ L (2 362.24 ... 2 559.06 inch)
IP66/IP68 (0.2 bar) M20x1.5/blind stopper 65 001 ... 70 000 mm 9 R2U
Stainless steel (precision casting) 316L/ M (2 559.09 ... 2 755.91 inch)
IP66/IP68 (0.2 bar) ½" NPT/blind stopper 70 001 ... 75 000 mm 9 R2V
Stainless steel (electropolished) 316L/ N (2 759.94 ... 2 952.76 inch)
IP66/IP68 (0.2 bar) M20x1.5/blind stopper Coax ø21.3 mm/316L
Stainless steel (electropolished) 316L/ P 300 ... 1 000 mm (11.81 ... 39.37 inch)22) 9 R3A
IP66/IP68 (0.2 bar) ½" NPT/blind stopper
1 001 ... 2 000 mm (39.41 ... 78.74 inch)22) 9 R3B
Stainless steel double chamber/IP66/ Q
2 001 ... 3 000 mm (78.78 ... 118.11 inch)22) 9 R3C
IP68 (0.2 bar) M20x1.5/blind stopper
Stainless steel double chamber/IP66/ R 3 001 ... 4 000 mm (118.15 ... 157.48 inch)22) 9 R3D
IP68 (0.2 bar) ½" NPT/blind stopper 4 001 ... 5 000 mm (157.52 … 196.85 inch)22) 9 R3E
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ S 5 001 … 6 000 mm (196.89 … 236.22 inch)22) 9 R3F
cable gland stainless steel Coax ø42.2 mm/316L
Aluminium double chamber/IP66/IP68 T
(0.2 bar) M20x1.5/cable gland stainless steel 300 ... 1 000 mm (11.81 ... 39.37 inch)22) 9 R3G
Stainless steel (precision casting) 316L/IP66/ 1 001 ... 2 000 mm (39.41 ... 78.74 inch)22) 9 R3H
U
IP68 (0.2 bar) M20x1.5/cable gland stainless 2 001 ... 3 000 mm (78.78 ... 118.11 inch)22) 9 R3J
steel
3 001 ... 4 000 mm (118.15 ... 157.48 inch)22) 9 R3K
Stainless steel (electropolished) 316L/IP66/IP68 V 4 001 ... 5 000 mm (157.52 … 196.85 inch)22) 9 R3L
(0.2 bar) M20x1.5/cable gland stainless steel 5 001 … 6 000 mm (196.89 … 236.22 inch)22) 9 R3M
Aluminium single chamber / IP66/IP68 W
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated

4/296 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Order code
SITRANS LG250 7ML5881- Further designs (optional)
A guided wave radar sensor for continuous 77777 - 7777 777 Please add "-Z" to Article No. and specify Order
level and interface measurement of liquids. code(s).
Further designs (mandatory) Order Code Enter the total insertion length in plain text descrip- Y01
tion
Please add "-Z" to Article No. and specify
Order code(s). Enter the total length of rigid part (cable version Y02
only)
Supplementary electronics
Without A00 Cleaning included certificate: oil, grease and W01
silicone free
Additional current output 4 ... 20 mA1)39) A01
Identification Label (measurement loop) stainless Y17
Dimensions centering weight steel
(diameter/height)
Without B00 Identification Label (measurement loop) Foil Y18
ø40/30 mm B01 3.1 Certificate instrument30) C12
ø45/30 mm (for 2 inch tubes) B02 3.1 Certificate material (NACE0175)30) D07

4
ø75/30 mm (for 3 inch tubes) B03 3.1-Certificate instrument with test data30) C25
ø95/30 mm (for 4 inch tubes) B04
ø1.57/1.18 inch (for 2 inch schedule 160) B05 2.2-Certificate material30) C15

ø1.77/1.18 inch (for 2 inch schedule 40/80) B06 Quality/test plan30) C26
ø2.95/1.18 inch (for 3 inch schedule 10/40) B07 Dye penetration test + 3.1 certificate/instrument30) C13
ø3.74/1.18 inch (for 4 inch schedule 80) B08 X-ray test + 3.1 certificate/instrument30) C14
Rod mounted Positive material identification test + 3.1 certificate/ C16
Without Rod, applicable for coax or cable C00 instrument30)
probe types only18)
Roughness test + 3.1 certificate/instrument30) C18
Mounted C01
Not mounted C02 Pressure test + 3.1 certificate/instrument30) C31
Local display interface Helium leak test + 3.1 certificate/instrument30) C32
Without13) E00 Ferrite measuring accuracy to DIN32514-1 + 3.1 C60
Mounted E01 certificate/instrument30)
Laterally mounted1) E02 Pressure test according to Norsok + 3.1 certificate/ C61
Language of display instrument30)
German L00 5 point calibration certificate + 3.1 certificate/ C62
English L01 instrument30)41)
French L02 Additional Operating Instructions Article No.
Dutch L03
German
Italian L04
4 … 20 mA/HART - two-wire PBD-51041010
Spanish L05
Portuguese L06 4 … 20 mA/HART - two-wire coax probe PBD-51041011
Russian L07 4 … 20 mA/HART - four-wire PBD-51041012
Chinese L08 4 … 20 mA/HART - four-wire coax probe PBD-51041013
Japanese L09
Modbus PBD-51041014
Operating instructions
German M00 Modbus- coax probe PBD-51041015
English M01 PROFIBUS PA PBD-51041016
French M02 PROFIBUS PA - coax probe PBD-51041017
Spanish M03
English
4 … 20 mA/HART - two-wire PBD-51041047
4 … 20 mA/HART - two-wire Coax probe PBD-51041048
4 … 20 mA/HART - four-wire PBD-51041049
4 … 20 mA/HART - four-wire Coax probe PBD-51041050
Modbus PBD-51041051
Modbus - coax probe PBD-51041052
PROFIBUS PA PBD-51041053
PROFIBUS PA - coax probe PBD-51041054

Siemens FI 01 · 2015 4/297


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
1) Available with Housing/Protection cable options E, F, Q, and R only
Selection and Ordering data Article No. 2) Not available with Process fitting/Material options 04, 05, 08, 10, 13, and
French 14
3)
4 … 20 mA/HART - two-wire PBD-51041121 Available only with Process Fitting/Material options 00 ... 10, 11, 12, 23 ...
34 and 37 ... 45 (Not available with threaded connections less than 1.5
4 … 20 mA/HART - two-wire Coax probe PBD-51041122 inch and flanges < DN 50/2 inch)
4) Available with Seal option N only
4 … 20 mA/HART - four-wire PBD-51041123 5)
Not available with Process fitting/Material options 00 ... 10, 11, 12, 23 ... 34
4 … 20 mA/HART - four-wire Coax probe PBD-51041124 and 37 ... 45. (Not available with threaded connections less than 1.5 inch
and flanges < DN 50/2 inch)
Modbus PBD-51041125 6)
Available only with Process fitting/Material options 00 and 01 (options with
max temp of 80 °C (176 °F) only available with PN 6 rated threaded con-
Modbus- coax probe PBD-51041126 nections)
7) Available with Version/Material option J only
PROFIBUS PA PBD-51041127
8) Available only with the same diameter probe lengths
PROFIBUS PA - coax probe PBD-51041128 9) Available with Rod mounted option C00 only (Coax and cable version
Spanish only)
10)
Available with Rod mounted options C01, C02 only (rod versions only)
4 … 20 mA/HART - two-wire PBD-51041084 11)
Available only with Centering weight option B00 (no centering weight
4 … 20 mA/HART - two-wire Coax probe PBD-51041085 option)
12)

4
Available with Centering weight options B01 ... B08 only
4 … 20 mA/HART - four-wire PBD-51041086 13)
Available only with Housing/Protection cable options E,F, Q, R, T (double
4 … 20 mA/HART - four-wire Coax probe PBD-51041087 chamber options only)
14) Available only with Housing/Protection cable options C, D, L, M and
Modbus PBD-51041088 approval option 1D
15)
Modbus- Coax probe PBD-51041089 Available with Supplementary electronic option A00 and Indicating/Adjust-
ment modules E00, E01
PROFIBUS PA PBD-51041090 16)
Available with Supplementary electronic option A01 and Approval options
0A,0E, and 0P
PROFIBUS PA - coax probe PBD-51041091 17) Not Available with Approval options 0B ... 0H 0P, 0Q,1B, and 1F (not avail-
Accessories able with Intrinsically Safe and shipping approvals)
19)
Not available with Length options 3, 4, 5, R2C and R2D
Sitrans LG, GWR sensor Display Module A5E34143449 20
) Available only with Seal options C,E,F,J,M, N and Q [second line of
SITRANS RD100, loop powered display - 7ML5741-... defense (with glass seal) for all explosion proof options]
21)
see Chapter 7 Available with Indicating/adjustment modules E00 and E01
22)
Not available with Y02
SITRANS RD200, universal input display with 7ML5740-... 23)
Available with Housing/Protection options C, D, E,F,L,M,Q,R (dust approv-
Modbus conversion - see Chapter 7 als)
24) SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
SITRANS RD300, dual line display with totalizer 7ML5744-...
0L, 0M, 0N, 0P, 0U, 0Q 0T,1A, 1B, 1D, 1E, 1F and 1H
and linearization curve and Modbus conversion - 25)
Available with Process Fitting/Material options 04,05,08,10,13 ... 45
see Chapter 7 26)
Not available with Process fitting /Material options 04,05,08,10,13, and14
SITRANS RD500 web, universal remote monitoring 7ML5750-... 27)
Not available with Process Fitting/Material options 00 and 01
28)
solution for instrumentation - see Chapter 7 Available with Housing/Protection/Cable options A,B,C,D,E,F,L,M,R,S,T,
and U
For applicable back up point level switch - 29)
Available with Electronic option 0 only
see point level measurement section 30)
Listed Certificates are not available with all configurations, please contact
factory for more information
31) Not available with Process fitting/Material options 02, 03, 06, 07, 11, and
12 or threaded options below PN 100
32)
Available with supplementary electronic option A00, SIL electronics
33)
Modbus only available with Approval options GP and NI and XP-IS/Ex d ia
34)
Modbus only available with two chamber housing options
35)
Modbus not available with Supplementary electronic (only for HART)
option
36)
Modbus not available with lateral mount display option
37)
Not available with version/material option K
38)
Not available with Seal/Process temperature options A,G K and Q
39)
Not available Indicating/adjustment module E02
40)
Available with Housing/protection options D, F, M,R (dust approvals)
41)
Available with Version/Material A, B, C, D, E and F

4/298 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
.E

Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG260 7ML5882- SITRANS LG260 7ML5882-
A guided wave radar sensor for level measu- 77777 - 7777 777 A guided wave radar sensor for level measu- 77777 - 7777 777
rement of solids. rement of solids.
Click on the Article No. for the online con- Process fitting/Material
figuration in the PIA Life Cycle Portal.
Thread G¾" (DIN 3852-A) PN 40/316L 00
Approvals Thread ¾" NPT (ASME B1.20.1) PN 40/316L 01
Ordinary location CE4)12) 0A Thread G1" (DIN 3852-A) PN 40/316L 02
Shipping approval9)10) 0B Thread 1" NPT (ASME B1.20.1) PN 40/316L 03
ATEX II 1G, 1/2G, 2G Ex ia IIC T64)12) 0E Thread G1½" (DIN 3852-A) PN 40/316L 04
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping 0G Thread 1½" NPT (ASME B1.20.1) PN 40/316L 05
approval GL9) Thread G2" (DIN 3852-A) PN 40/316L 06
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 0H Flange DN 50 PN 40 Form C, DIN 2501/316L 10
1/2D, 1/3D, 2D, Ex t IIIC IP66 T8)10)12)21)
Flange DN 80 PN 40 Form C, DIN 2501/316L 12
ATEX II 1/2G, 2G Ex d ia IIC T61)7)12) 0J
Flange DN 100 PN 16 Form C, DIN 2501/316L 13
ATEX II 1/2G, 2G Ex d ia IIC + shipping 0L
approval (GL)1)7)9)10)
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D, 0M
Flange DN 100 PN 40 Form C, DIN 2501/316L
Flange DN 150 PN 16 Form C, DIN 2501/316L
14
15 4
1/3D, 2D, Ex t IIIC IP667)8)12)21) Flange DN 50 PN 40 EN1092-1 Form B1/316L 16
ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC 0N Flange DN 80 PN 40 EN1092-1 Form B1/316L 17
IP6611)12) Flange DN 100 PN16 EN1092-1 Form B1/316L 18
ATEX II 1/2G, 2G Ex d IIC + shipping 0Q Flange 2" 150 lb RF, ANSI B16.5/316L 30
approval (GL)9)10)11)
Flange 2" 300 lb RF, ANSI B16.5/316L 32
ATEX II 1/2G,2G Ex d IIC + II 1D, 1/2D, 1/3D, 0R
2D IP668)11)12)21) Flange 3" 150 lb RF, ANSI B16.5/316L 33
ATEX II 1D, 1/2D, 2D IP6x T8)11)12)21) 0S Flange 3" 300 lb RF, ANSI B16.5/316L 34
IEC Ex ia IIC T64)12) 0T Flange 4" 150 lb RF, ANSI B16.5/316L 35
IEC Ex ia IIC T6 + IEC IP6x T tD8)11)12)21) 0U Flange 4" 300 lb RF, ANSI B16.5/316L 36
IEC Ex d ia IIC T61)7)12) 1A Flange 6" 150 lb RF, ANSI B16.5/316L 37
IEC Ex d ia IIC T6 + IEC IP6x T tD7)8)12)21) 1B Electronics
IEC Ex d IIC T611)12) 1C Two-wire 4 ... 20mA/HART 0
IEC Ex d IIC T6 + IEC IP6x T tD8)11)12)21) 1D Four-wire Modbus16)17)18)19) 1
FM (NI) Class I,Div. 2, Groups A, B, C, D12) 1F Two-wire 4...20mA/HART with SIL 2
qualification14)15)
FM (NI) Class I, Div. 2, Groups A, B, C, D + 1G
shipping approval (GL)9)10) Four-wire 4...20mA/HART; 90...253V AC; 3
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1H 50/60Hz1)3)5)
D, E, F12) Four-wire 4...20mA/HART; 9.6...48V DC; 4
20...42 V AC1)3)5)
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1J
D, E, F, G + shipping approval (GL)9)10) PROFIBUS PA 5
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, 1K Seal/Process temperature
C, D, E, F, G1)7)12) A
FKM (SHS FPM 70C3 GLT)/-40 ... +80 °C
FM (XP-IS) Class I, II, III, Div. 1, Groups A, 1L (-40 ... +176 °F)
B, C, D, E, F, G + shipping approval
(GL)1)7)9)10) FKM (SHS FPM 70C3 GLT)/-40 ... +150 °C B
(-40 ... +302 °F)
FM (XP) Class I, Div. 1, Groups A, B, C, 1M FFKM (Kalrez 6375)/-20 ... +200 °C C
D11)12) (-4 ... +392 °F)
CSA (NI) Class I, Div. 2,Groups A, B, C, D; 1N
(DIP) Class II, III, Div. 1, Groups E, F, G8)12) EPDM (A+P 75.5/KW75F)/-40 ... +80 °C D
(-40 ... +176 °F)
CSA (IS) Class I, II, III, Div.1, Groups A, B, C, 1P
D, E, F, G12) EPDM (A+P 75.5/KW75F)/-40 ... +150 °C E
(-40 ... +392 °F)
CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1Q
B, C, D, E, F, G1)7)12) Housing/Protection/Cable
CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1R Plastic IP66/IP67 M20x1.5/blind stopper A
C, D, E, F, G11)12) Plastic IP66/IP67 ½" NPT/blind stopper B
Probe version/Material Plastic 2-chamber/IP66/IP67/M20x1.5/ C
Probe exchangeable cable ø 4 mm A blind stopper
(0.16 inch) with gravity weight/316 Plastic 2-chamber/IP66/IP67 /½" NPT/ D
Probe exchangeable cable B blind stopper
ø 6 mm (0.24 inch) with gravity weight/3162) Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ E
Probe exchangeable rod ø 16 E blind stopper
mm (0.63 inch) / 316L2)6) Aluminium/IP66/IP68 (0.2 bar) ½" NPT/ F
blind stopper
Aluminium double chamber/IP66/IP68 G
(0.2 bar) M20x1.5/blind stopper
Aluminium double chamber/IP66/IP68 H
(0.2 bar) ½" NPT/blind stopper
Stainless Steel (precision casting) 316L/IP66/ J
IP68 (0.2 bar) M20x1.5/blind stopper

Siemens FI 01 · 2015 4/299


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG260 7ML5882- SITRANS LG260 7ML5882-
A guided wave radar sensor for level measu- 77777 - 7777 777 A guided wave radar sensor for level measu- 77777 - 7777 777
rement of solids. rement of solids.
Stainless steel (precision casting) 316L/IP66/ K Cable lengths ø6 mm/316L
IP68 (0.2 bar) ½" NPT/blind stopper
500 mm (19.69 inch) 9 R4A
Stainless steel (electropolished) 316L/IP66/ L
IP68 (0.2 bar) M20x1.5/blind stopper 501 ... 1 000 mm (19.72 ... 39.37 inch) 9 R4B
Stainless steel (electropolished) 316L/IP66/ M 1 001 ... 5 000 mm (39.41 ... 196.85 inch) 9 R4C
IP68 (0.2 bar) ½" NPT/blind stopper 5 001 ... 10 000 mm (196.89 ... 393.70 inch) 9 R4D
Stainless steel double chamber/IP66/IP68 N 10 001 ... 15 000 mm (393.74 ... 590.55 inch) 9 R4E
(0.2 bar) M20x1.5/blind stopper 15 001 ... 20 000 mm 9 R4F
Stainless steel double chamber/IP66/IP68 P (590.59 ... 787.40 inch)
(0.2 bar) ½" NPT/blind stopper 20 001 ... 25 000 mm 9 R4G
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ Q (787.44 ... 984.25 inch)
cable gland stainless steel 25 001 ... 30 000 mm 9 R4H
Aluminium double chamber/IP66/IP68 R (984.29 ... 1 181.10 inch)

4 (0.2 bar) M20x1.5/cable gland stainless steel


Stainless steel (precision casting) 316L/IP66/ S
30 001 ... 35 000 mm
(1 181.14 ... 1 377.95 inch)
9 R4J

IP68 (0.2 bar) M20x1.5/cable gland stainless 35 001 ... 40 000 mm 9 R4K
steel (1 377.99 ... 1 574.80 inch)
Stainless steel (electropolished) 316L/IP66/ T 40 001 ... 45 000 mm 9 R4L
IP68 (0.2 bar) M20x1.5/cable gland stainless (1 574.84 ... 1 771.65 inch)
steel
45 001 ... 50 000 mm 9 R4M
Aluminium single chamber / IP66/IP68 W (1 771.69 ... 1 968.50 inch)
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated 50 001 ... 55 000 mm 9 R4N
(1 968.54 ... 2 165.35 inch)
Aluminium double chamber / IP66/IP68 X
(0.2 bar) M20x1.5 / Cable gland brass 55 001 ... 60 000 mm 9 R4P
nickel-plated (2 165.39 ... 2 362.20 inch)
Stainless steel single chamber (precision Y Further designs (mandatory) Order Code
casting) / IP66/IP68 (0.2 bar) M20x1.5 /
Please add "-Z" to Article No. and specify
Cable gland brass nickel-plated
Order code(s).
Lengths
Supplementary electronics
Rod ø16 mm/316L Without1) A00
500 mm (19.69 inch) 0 Additional current output 4 ... 20 mA1)20) A01
501 ... 1 000 mm (19.72 ... 39.37 inch) 1 Rod mounted
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 Without Rod, applicable for coax or cable C00
2 001 ... 3 000 mm (78.78 ... 118.11 inch) 3 probe types only
3 001 ... 4 000 mm (118.15 ... 157.48 inch) 4 Mounted C01
Not mounted C02
4 001 ... 5 000 mm (157.52 ... 196.85 inch) 5
5 001 ... 6 000 mm (196.89 ... 216.53 inch) 6 Local display interface
Without E00
Cable lengths ø2 or 4 mm/316 Mounted E01
501 ... 1 000 mm (19.72 ... 39.37 inch) 9 R2E Laterally mounted1) E02
1 001 ... 5 000 mm (39.41 ... 196.85 inch) 9 R2F Language of display
5 001 ... 10 000 mm (196.89 ... 393.70 inch) 9 R2G German L00
10 001 ... 15 000 mm (393.74 ... 590.55 inch) 9 R2H English L01
15 001 ... 20 000 mm (590.59 ... 787.40 inch) 9 R2 J French L02
20 001 ... 25 000 mm (787.44 ... 984.25 inch) 9 R2K Dutch L03
25 001 ... 30 000 mm 9 R2L Italian L04
(984.29 ... 1 181.10 inch) Spanish L05
30 001 ... 35 000 mm 9 R2M Portuguese L06
(1 181.14 ... 1 377.95 inch) Russian L07
35 001 ... 40 000 mm 9 R2N Chinese L08
(1 377.99 ... 1 574.80 inch)
Japanese L09
40 001 ... 45 000 mm 9 R2P
(1 574.84 ... 1 771.65 inch) Operating instructions
45 001 ... 50 000 mm 9 R2Q German M00
(1 771.69 ... 1 968.50 inch) English M01
French M02
50 001 ... 55 000 mm 9 R2R
(1 968.54 ... 2 165.35 inch) Spanish M03
55 001 ... 60 000 mm 9 R2S
(2 165.39 ... 2 362.20 inch)

4/300 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Order code Selection and Ordering data Article No.
Further designs (optional) Accessories
Please add "-Z" to Article No. and specify Order Sitrans LG, GWR sensor Display Module A5E34143449
code(s).
SITRANS RD100, loop powered display - 7ML5741-...
Enter the total insertion length in plain text descrip- Y01 see Chapter 7
tion
SITRANS RD200, universal input display with 7ML5740-...
Cleaning included certificate: oil, grease and sili- W01
cone free Modbus conversion - see Chapter 7

Identification Label (measurement loop) stainless Y17 SITRANS RD300, dual line display with totalizer 7ML5744-...
steel and linearization curve and Modbus conversion -
see Chapter 7
Identification Label (measurement loop) Foil Y18
SITRANS RD500 web, universal remote monitoring 7ML5750-...
3.1 Certificate instrument13) C12
solution for instrumentation - see Chapter 7
3.1 Certificate material (NACE0175)13) D07
For applicable back up point level switch -
3.1-Certificate instrument with test data13) C25 see point level measurement section
2.2-Certificate material13) C15 1)

4
Available only with Housing/Protection/Cable Options G, H, N, P
Quality/test plan13) C26 2)
Not available with Process/Fitting/Material options 00, 01, 02, and 03
3)
Dye penetration test + 3.1 certificate/instrument13) C13 Available with Supplementary electronic option A00 and Indicating/adjust-
ment modules E00, E01
X-ray test + 3.1 certificate/instrument13) C14 4)
Available with Supplementary electronic option A01
5)
Not Available with Approval options 0B ... 0H 0L, 0Q, 1B, 1F, 1G,1J, 1L
Positive material identification test + 3.1 certificate/ C16
(not available with Intrinsically Safe and shipping approvals)
instrument 13) 6)
Available with Rod Mounted options C01 and C02
7)
Roughness test + 3.1 certificate/instrument13) C18 8)
Available with Indicating/adjustment modules E00 and E01
Available with Housing Protection options E, F, G, H, J, K, N, P
Pressure test + 3.1 certificate/instrument13) C31 9)
Not available with Housing/Protection/Cable options L, M, and T
10)
Available with Electronic option 0 only
Helium leak test + 3.1 certificate/instrument13) C32 11)
Available with Seal/Process temperature option C only
12)
Ferrite measuring accuracy to DIN32514-1 + 3.1 C60 Available with Version/Material option E only
13)
certificate/instrument13) Listed Certificates are not available with all configurations, please contact
factory for more information
Pressure test according to Norsok + 3.1 certificate/ C61 14)
SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
instrument13) 0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P, and 1R
15)
Available with supplementary electronic option A00, SIL electronics
5 point calibration certificate + 3.1 certificate/ C62 16)
Modbus available only with Approval options GP and NI and XP-IS/
instrument13) Ex d ia
17)
Operating Instructions Article No. Modbus available only with two chamber housing options
18)
Modbus not available with supplementary electronic (only for HART)
German option
19)
Modbus not available with lateral mount display option
4 … 20 mA/HART - two-wire PBD-51041020 20)
Not available with Indicating/adjustment module E02
21)
4 … 20 mA/HART - four-wire PBD-51041021 Available with Housing Protection F, H, P and K

Modbus PBD-51041022
PROFIBUS PA PBD-51041023
English
4 … 20 mA/HART - two-wire PBD-51041057
4 … 20 mA/HART - four-wire PBD-51041058
Modbus PBD-51041059
PROFIBUS PA PBD-51041060
French
4 … 20 mA/HART - two-wire PBD-51041131
4 … 20 mA/HART - four-wire PBD-51041132
Modbus PBD-51041133
PROFIBUS PA PBD-51041134
Spanish
4 … 20 mA/HART - two-wire PBD-51041094
4 … 20 mA/HART - four-wire PBD-51041095
Modbus PBD-51041096
PROFIBUS PA PBD-51041097

Siemens FI 01 · 2015 4/301


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG270 7ML5883- SITRANS LG270 7ML5883-
A guided wave radar sensor for continuous 77777 - 7777 777 A guided wave radar sensor for continuous 77777 - 7777 777
level and interface measurement of liquids in level and interface measurement of liquids in
aggressive applications aggressive applications
Click on the Article No. for the online con- Process fitting/Material
figuration in the PIA Life Cycle Portal.
Thread G1½" (DIN 3852-A) PN400/316L 00
Approvals Thread 1½" NPT (ASME B1.20.1) PN400/316L 01
Ordinary location CE3) 0A Thread 1½" NPT (ASME B1.20.1) PN400/C22 02
Shipping approval17)18)19) 0B
Flange DN 50 PN 40 Form C, DIN 2501/316L 10
ATEX II 1G, 1/2G, 2G Ex ia IIC T63) 0E
Flange DN 50 PN 40 form V13, DIN 2513/316L 11
ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping 0G Flange DN 65 PN 64 Form V13, DIN 2501/316L 12
approval GL17)18)19)
ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 0H Flange DN 80 PN 40 Form C, DIN 2501/316L 13
1/2D, 2D IP6x16)28) Flange DN 80 PN 40 Form V13, DIN 2501/316L 14
ATEX II 1/2G, 2G Ex d ia IIC T61)10)14) 0J Flange DN 80 PN 100 Form L, DIN 2501/316L 15

4 ATEX II 1/2G, 2G Ex d ia IIC + ship 0L Flange DN 100 PN 16 Form C, DIN 2501/316L 16


(GL)1)10)14)17)18)19) Flange DN 100 PN 16 Form C, DIN 2501/316L 17
ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D, 0M Flange DN 100 PN 40 Form C, DIN 2501/316L 18
2D IP6x10)14)16)28)
Flange DN 100 PN 40 Form V13, DIN 2513/ 20
ATEX II 1/2G, 2G Ex d IIC T611) 0N 316L
ATEX II 1/2G, 2G Ex d IIC + ship approval 0Q Flange DN 150 PN 16 Form C, DIN 2501/316L 21
(GL)3)17)18)19) Flange DN 50 PN 40 EN1092-1 Form B1/316L 22
ATEX II 1/2G, 2G Ex d IIC + ATEX II 1/2D, 2D 0R
IP6x11)16)28) Flange DN 100 PN 160 GOST 12815-80.7/ 23
316L
ATEX II 1D, 1/2D, 2D IP6x T16)28) 0S
Flange DN 80 PN 160 Form C, DIN 2501/316L 60
IEC Ex ia IIC T6 0T Flange DN 80 PN 250 Form L, DIN 2501/316L 61
IEC Ex ia IIC T6 + IEC IP6x T tD16)28) 0U
Flange DN 50 PN 160, EN1092-1 Form B1/ 62
IEC Ex d ia IIC T61)10)14) 1A 316L
IEC Ex d ia IIC T6 + IEC IP6x T tD10)14)16)28) 1B Flange DN 50 PN 160, EN1092-1 Form B2/ 63
IEC Ex d IIC T611) 1C 316L
IEC Ex d IIC T6 + IEC IP6x T tD11)16)28) 1D Flange DN 50 PN 320, EN1092-1 Form B1/ 64
316L
FM (NI) Class I, Div.2, Groups A, B, C, D 1F
FM (NI) Class I, Div.2, Groups A, B, C, D + 1G Flange DN 65 PN 250, EN1092-1 Form B1/ 65
ship approval (GL)17)18)19) 316L
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1H Flange DN 100 PN 160, EN1092-1 Form B2/ 66
D, E, F 316L
Flange 2" 150 lb RF, ANSI B16.5/316L 30
FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1J
D, E, F, G + ship approval (GL)17)18)19) Flange 2" 300 lb RF, ANSI B16.5/316L 31
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, 1K Flange 2" 600 lb RF, ANSI B16.5/316L 32
C, D, E, F, G1)10)14) Flange 2" 1 500 lb RF, ANSI B16.5/316L 33
FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, 1L Flange 3" 150 lb RF, ANSI B16.5/316L 34
C, D, E, F, G + shipping approval
(GL)1)10)17)18)19) Flange 3" 300 lb RF, ANSI B16.5/316L 35
Flange 3" 600 lb RF, ANSI B16.5/316L 36
FM (XP) Class I, Div.1, Groups A, B, C, D 1M
CSA (NI) Class I, Div. 2, Groups A, B, C, D; 1N Flange 3" 900 lb RF, ANSI B16.5/316L 37
(DIP) Class II, III, Div.1, Groups E, F, G16) Flange 3" 2 500 lb RF, ANSI B16.5/316L 38
CSA (IS) Class I, II, III, Div.1, Groups A, B, C, 1P Flange 3 ½" 600 lb RF, ANSI B16.5/316L 40
D, E, F, G Flange 4" 150 lb RF, ANSI B16.5/316L 41
CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1Q Flange 4" 300 lb RF, ANSI B16.5/316L 42
B, C, D, E, F, G1)10)14) Flange 4" 600 lb RF, ANSI B16.5/316L 43
CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1R
C, D, E, F, G11) Flange 6" 150 lb RF, ANSI B16.5/316L 44
Flange 6" 300 lb RF, ANSI B16.5/316L 45
Version/Material Flange 6" 600 lb RF, ANSI B16.5/316L 46
Probe exchangeable cable ø 2 mm A Flange 2"150 lb Fisher special return/316L 47
(0.08 inch) with gravity weight/316L4)7)
Flange 2" 900 lb RF, ANSI B16.5/316L 50
Probe exchangeable cable ø2 mm B
(0.08 inch) center weight/316L 5)7) Flange 3" 1 500 lb RF, ANSI B16.5/316L 51
Probe exchangeable cable ø4 mm C Flange 4" 900 lb RF, ANSI B16.5/316L 52
(0.16 inch) with gravity weight/316L4)7) Flange 4" 1 500 lb RF, ANSI B16.5/316L 53
Probe exchangeable cable ø4 mm D Flange 4" 2 500 lb RJF, ANSI B16.5/316L 54
(0.16 inch) with center weight/316L5)7)
Probe exchangeable rod ø 16 mm E
(0.63 inch) /316L4)7)9)
Probe coax version ø 42.2 mm (1.66 inch) F
with multiple hole/316L4)7)
Probe coax version ø 42.2 mm (1.66 inch); G
multiple hole; reference distances/
316L4)7)13)

4/302 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code
SITRANS LG270 7ML5883- SITRANS LG270 7ML5883-
A guided wave radar sensor for continuous 77777 - 7777 777 A guided wave radar sensor for continuous 77777 - 7777 777
level and interface measurement of liquids in level and interface measurement of liquids in
aggressive applications aggressive applications
Electronics Lengths
Two-wire 4 ... 20mA/HART 0 Rod ø16 mm/316L
Four-wire Modbus23)24)25)26) 1
Two-wire 4...20mA/HART with SIL 2 300 mm (11.81 inch)15) 0
qualification21)22) 500 mm (19.69 inch)15) 1
501 ... 1 000 mm (19.72 ... 39.37 inch)15) 2
Four-wire 4...20mA/HART; 90...253V AC; 50/ 3
60Hz1)2)6) 1 001 ... 2 000 mm (39.41 ... 78.74 inch)15) 3
Four-wire 4...20mA/HART; 9.6...48V DC; 4 2 001 ... 3 000 mm (78.78 ... 118.11 inch)15) 4
20...42 V AC1)2)6) 3 001 ... 4 000 mm 5
PROFIBUS PA 5 (118.15 ... 157.48 inch)15)
Seal/Second line of defense/ 4 001 ... 5 000 mm 6
Process temperature (157.52 ... 196.85 inch)15)
Ceramic-graphite/with glass seal/
-196 ... +280 °C (-321 ... +536 °F)
A 5 001 ... 6 000 mm
(196.89 ... 216.53 inch)15)
7 4
Ceramic-graphite /with glass seal/ B Cable lengths ø2 or 4 mm/316L
-196 ... +450 °C (-321 ... +842 °F)
501 ... 1 000 mm (19.72 ... 39.37 inch) 9 R2E
Housing/Protection/Cable
1 000 ... 5 000 mm (39.37 ... 196.85 inch) 9 R2F
Plastic IP66/IP67 M20x1.5/blind stopper A 5 001 ... 10 000 mm (196.89 ... 393.70 inch) 9 R2G
Plastic IP66/IP67 ½" NPT/blind stopper B
10 001 ... 15 000 mm (393.74 ... 590.55 inch) 9 R2H
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ C
blind stopper 15 001 ... 20 000 mm (590.59 ... 787.40 inch) 9 R2J
20 001 ... 25 000 mm (787.44 ... 984.25 inch) 9 R2K
Aluminium/IP66/IP68 (0.2 bar) ½" NPT/ D
blind stopper 25 001 ... 30 000 mm 9 R2L
Aluminium double chamber/IP66/IP68 E (984.29 ... 1 181.10 inch)
(0.2 bar) M20x1.5/blind stopper 30 001 ... 35 000 mm 9 R2M
Aluminium double chamber/IP66/IP68 F (1 181.14 ... 1 377.95 inch)
(0.2 bar) ½" NPT/blind stopper 35 001 ... 40 000 mm 9 R2N
(1 377.99 ... 1 574.80 inch)
Stainless steel (precision casting) 316L/ L
IP66/IP68 (0.2 bar) M20x1.5/blind stopper 40 001 ... 45 000 mm 9 R2P
Stainless steel (precision casting) 316L/ M (1 574.84 ... 1 771.65 inch)
IP66/IP68 (0.2 bar) ½" NPT/blind stopper 45 001 ... 50 000 mm 9 R2Q
Stainless steel (electropolished) 316L N (1 771.69 ... 1 968.50 inch)
IP66/IP68 (0.2 bar) M20x1.5/blind stopper 50 001 ... 55 000 mm 9 R2R
Stainless steel (electropolished) 316L/ P (1 968.54 ... 2 165.35 inch)
IP66/IP68 (0.2 bar) ½" NPT/blind stopper 55 001 ... 60 000 mm 9 R2S
Stainless steel double chamber/IP66/IP68 Q (2 165.39 ... 2 362.20 inch)
(0.2 bar) M20x1.5/blind stopper Coax ø42.2 mm/316L
Stainless steel double chamber/IP66/IP68 R
300 ... 1 000 mm (11.81 ... 39.37 inch)15) 9 R3G
(0.2 bar) ½" NPT/blind stopper
1 001 ... 2 000 mm (39.41 ... 78.74 inch)15) 9 R3H
Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ S 2 001 ... 3 000 mm (78.78 ... 118.11 inch)15) 9 R3J
cable gland stainless steel
Aluminium double chamber/IP66/IP68 T 3 001 ... 4 000 mm 9 R3K
(0.2 bar) M20x1.5/cable gland stainless steel (118.15 ... 157.48 inch)15)
Stainless steel (precision casting) 316L/ U 4 001 ... 5 000 mm 9 R3L
IP66/IP68 (0.2 bar) M20x1.5/Cable gland (157.52 … 196.85 inch)15)
stainless steel 5 001 … 6 000 mm 9 R3M
(196.89 … 236.22 inch)15)
Stainless steel (electropolished) 316L/ V
IP66/IP68 (0.2 bar) M20x1.5/cable gland
stainless steel
Aluminium single chamber / IP66/IP68 W
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Aluminium double chamber / IP66/IP68 X
(0.2 bar) M20x1.5 / Cable gland brass
nickel-plated
Stainless steel single chamber (precision Y
casting) / IP66/IP68 (0.2 bar) M20x1.5 /
Cable gland brass nickel-plated

Siemens FI 01 · 2015 4/303


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No. Order Code Selection and Ordering data Order code
SITRANS LG270 7ML5883- Further designs (optional)
A guided wave radar sensor for continuous 77777 - 7777 777 Please add "-Z" to Article No. and specify Order
level and interface measurement of liquids in code(s).
aggressive applications
Enter the total insertion length in plain text descrip- Y01
Further designs (mandatory) Order Code tion
Please add "-Z" to Article No. and specify Enter the total length of rigid part (cable version Y02
Order code(s). only, to a maximum of 100 mm)
Supplementary electronics Cleaning included certificate: oil, grease and W01
Without A00 silicone free
Additional current output 4 ... 20 mA1)27) A01 Identification Label (measurement loop) stainless Y17
steel
Dimensions centering weight
(diameter/height) Identification Label (measurement loop) Foil Y18
Without B00 3.1 Certificate instrument20) C12
ø40/30 mm B01
3.1 Certificate material (NACE0175)20) D07
ø45/30 mm (for 2 inch tubes) B02

4 ø75/30 mm (for 3 inch tubes)


ø95/30 mm (for 4 inch tubes)
B03
B04
3.1-Certificate instrument with test data20)
2.2-Certificate material20)
C25
C15
ø1.57/1.18 inch (for 2 inch schedule 160) B05 Quality/test plan20) C26
ø1.77/ 1.18 inch (for 2 inch schedule 40/80) B06 Dye penetration test + 3.1 certificate/instrument20) C13
ø2.95/1.18 inch (for 3 inch schedule 10/40) B07
X-ray test + 3.1 certificate/instrument20) C14
ø3.74/ 1.18 inch (for 4 inch schedule 80) B08
Positive material identification test + 3.1 certificate/ C16
Rod mounted instrument20)
Without Rod, applicable for coax or cable C00
probe types only8) Roughness test + 3.1 certificate/instrument20) C18
Mounted C01 Pressure test + 3.1 certificate/instrument20) C31
Not mounted C02 Helium leak test + 3.1 certificate/instrument20) C32
Local display interface Ferrite measuring accuracy to DIN32514-1 + 3.1 C60
Without E00 certificate/instrument20)
Mounted E01 Pressure test according to Norsok + 3.1 certificate/ C61
Laterally mounted1) E02 instrument20)
Language of display 5 point calibration certificate + 3.1 certificate/ C62
German L00 instrument20)29)
English L01 Additional Operating Instructions Article No.
French L02 German
Dutch L03
Italian L04 4 … 20 mA/HART - two-wire PBD-51041025

Spanish L05 4 … 20 mA/HART - two-wire coax probe PBD-51041026


Portuguese L06 4 … 20 mA/HART - four-wire PBD-51041027
Russian L07 4 … 20 mA/HART - four-wire coax probe PBD-51041028
Chinese L08
Modbus PBD-51041029
Japanese L09
Modbus- Coax probe PBD-51041030
Operating instructions
German M00 PROFIBUS PA PBD-51041031
English M01 PROFIBUS PA, Coax probe PBD-51041032
French M02
English
Spanish M03
4 … 20 mA/HART - two-wire PBD-51041062
4 … 20 mA/HART - two-wire coax probe PBD-51041063
4 … 20 mA/HART - four-wire PBD-51041064
4 … 20 mA/HART - four-wire coax probe PBD-51041065
Modbus PBD-51041066
Modbus- coax probe PBD-51041067
PROFIBUS PA PBD-51041068
PROFIBUS PA, Coax probe PBD-51041069

4/304 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series
Selection and Ordering data Article No.
French
4 … 20 mA/HART - two-wire PBD-51041136
4 … 20 mA/HART - two-wire coax probe PBD-51041137
4 … 20 mA/HART - four-wire PBD-51041138
4 … 20 mA/HART - four-wire coax probe PBD-51041139
Modbus PBD-51041140
Modbus- Coax probe PBD-51041141
PROFIBUS PA PBD-51041142
PROFIBUS PA, Coax probe PBD-51041143
Spanish
4 … 20 mA/HART - two-wire PBD-51041099
4 … 20 mA/HART - two-wire coax probe PBD-51041100
4 … 20 mA/HART - four-wire
4 … 20 mA/HART - four-wire coax probe
PBD-51041101
PBD-51041102
4
Modbus PBD-51041103
Modbus- Coax probe PBD-51041104
PROFIBUS PA PBD-51041105
PROFIBUS PA, Coax probe PBD-51041105
Accessories
Sitrans LG, GWR sensor Display Module A5E34143449
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1)
Available with Housing/Protection/Cable options E, F, Q, R, and T
2) Available with Supplementary electronic option A00 and Indicating/adjust-
ment modules E00, E01
3)
Available with Supplementary electronics A01
4) Available with Centering weight option B00 only
5)
Available with Centering weight options B01 ... B08 only
6)
Available with Approval options 0A,0B,0J,0K,0N,0R,OS,1A,1C,1E,1F, and
1G
7)
Available only with the same diameter probe lengths
8)
Available with Version/Material options A, B, C, D, F, G
9) Available with Rod Mounted options C01 and C02
10)
Available with Indicating/adjustment modules E00 and E01
11)
Available with Housing/Protection Cable options C, D, L, M only
12) Version/Material Hastelloy C22, temperature is limited to 400 °C (752 °F)
13)
Not available with Length R3G
14) Available with Housing/Protection Cable options E, F, Q, and R
15) Y02 only available with Cable options
16)
Available with Housing protection options C, D, E,F,L, M,Q, and R
17) Not available with Housing/Protection/Cable options N, P, and V
18) Available with Electronic option 0 only
19)
Not available with Version/Material options E, F, and G
20) Listed Certificates are not available with all configurations, please contact
factory for more information
21)
SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H,
0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P and 1R
22) Available with Supplementary electronic option A00, SIL electronics
23)
Available with Approval options 0A, 0H, 0K, 0R, 0S, 0U, 1A, 1C, 1D, 1E, 1F,
1H, 1N, 1P and 1R
24) Modbus only available with two chamber housing options
25)
Modbus not available with Supplementary electronic (only for HART)
option
26) Modbus not available with lateral mount display option
27)
Not available with Indicating/adjustment module E02
28) Available with Housing protection options D, F, M and R
29) Available with Version/Material A, B, C, D and E

Siemens FI 01 · 2015 4/305


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

■ Characteristic curves
SITRANS LG240, Ambient temperature/process temperature, standard version

Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F)

4
0 °C Process
(32 °F)
150 °C
Temperature
-20 °C (302 °F)
(-68 °F)

-40 °C
(-104 °F)

SITRANS LG240, Ambient temperature/process temperature curve

4/306 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG250, Ambient temperature/process temperature, standard version

Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F) Limited
Temperature
65 °C Range
(149 °F)

0 °C
(32 °F)
Process
Temperature
4
80 °C 130 °C 150 °C
-40 °C (176 °F) (266 °F) (302 °F)
(-104 °F)

-40 °C
(-104 °F)

SITRANS LG250, Ambient temperature/process temperature, temperature adapter version

Ambient
Temperature

Maximum
Permissible
Temperature
80 °C
(176 °F) Limited
Temperature
Range
55 °C
(131 °F)

0 °C Process
(32 °F)
150 °C 200 °C
Temperature
-20 °C (302 °F) (392 °F)
(-68 °F)

-40 °C
(-104 °F)

SITRANS LG250, Ambient temperature/process temperature curves

Siemens FI 01 · 2015 4/307


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG260, Maximum tensile load with cereals and plastic granules - cable: ø 4 mm (0.157 inch)

1 1

12
6 3
3
10 5
4 4

8 4
5
5
6 3

6
4 2 6

2 1
2 2

4
0 0
"A" 0 5 10 15 20 25 30 35 "B" 0 5 10 15 20 25 30 35
A. Cereals
B. Plastic granules
1. Tensile force in kN (the determined value must be multiplied with safety factor 2)
2. Cable length in m
3. Vessel diameter 12 m (39.37 ft)
4. Vessel diameter 9 m (29.53 ft)
5. Vessel diameter 6 m (19.69 ft)
6. Vessel diameter 3 m (9.843 ft)

SITRANS LG260, Maximum tensile load with sand and cement - cable: ø 4 mm (0.157 inch)

1 1

20 20

18 18

16 3 16 3

14 14
4 4

12 12

10 5 10
5

8 8

6 6 6
6

4 4

2 2
2 2
0 0
"C" 0 5 10 15 20 25 30 35 "D" 0 5 10 15 20 25 30 35

C. Sand
D. Cement
1. Tensile force in kN (the determined value must be multiplied with safety factor 2)
2. Cable length in m
3. Vessel diameter 12 m (39.37 ft)
4. Vessel diameter 9 m (29.53 ft)
5. Vessel diameter 6 m (19.69 ft)
6. Vessel diameter 3 m (9.843 ft)

SITRANS LG260, Maximum tensile load curves

4/308 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG260, Ambient temperature/process temperature, standard version


Cable version with ø 4 mm (0.157 inch)
Cable version, PA coated with ø 6 mm (0.236 inch)

Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F) Limited
Temperature
65 °C Range
(149 °F)

0 °C Process
4
(32 °F)
130 °C 150 °C
Temperature
-40 °C (266 °F) (302 °F)
(-104 °F)

-40 °C
(-104 °F)

SITRANS LG260, Ambient temperature/process temperature, temperature adapter version


Cable version with ø 4 mm (0.157 inch)
Cable version, PA coated with ø 6 mm (0.236 inch)

Ambient
Temperature

Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
55 °C
(131 °F)

0 °C Process
(32 °F)
150 °C 200 °C
Temperature
-20 °C (302 °F) (392 °F)
(-68 °F)

-40 °C
(-104 °F)

SITRANS LG260, Ambient temperature/process temperature curves

Siemens FI 01 · 2015 4/309


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG260, Ambient temperature/process temperature, standard version


Cable version with ø 6 mm (0.236 inch)
Cable version, PA coated with ø 11 mm (0.433 inch)

Ambient
Temperature
Maximum
Permissible
Temperature

80 °C
(176 °F)

4
0 °C Process
(32 °F)
150 °C
Temperature
-40 °C (302 °F)
(-104 °F)

-40 °C
(-104 °F)

SITRANS LG260, Ambient temperature/process temperature, temperature adapter version


Cable version with ø 6 mm (0.236 inch)
Cable version, PA coated with ø 11 mm (0.433 inch)

Ambient
Temperature
Maximum
Permissible
Temperature
80 °C
(176 °F) Limited
Temperature
65 °C Range
(149 °F)

0 °C Process
(32 °F) Temperature
170 °C 200 °C
-20 °C (338 °F) (392 °F)
(-68 °F)

-40 °C
(-104 °F)

SITRANS LG260, Ambient temperature/process temperature curves

4/310 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG270, Ambient temperature /process temperature ( -196 … +280 °C/-321 … +536 °F version)

Ambient
Temperature

Maximum
Permissible
80 °C Temperature
(176°F)
65 °C Limited
(149 °F) Temperature
55 °C Range
(131 °F)

Process
4
0 °C
-196 °C -80 °C (32 °F) 190 °C 250 °C 280 °C Temperature
(-321 °F) (-112 °F) (374 °F) (482 °F) (536 °F)

-40 °C
(-104 °F)

SITRANS LG270, Ambient temperature/process temperature ( -196 … +450 °C/-321 … +842 °F version)

Ambient
Temperature

Maximum
Permissible
Temperature
80 °C
(176 °F)
Limited
Temperature
Range
35 °C
(95 °F)

0 °C Process
-196 °C -110 °C (32 °F) 220 °C 450 °C Temperature
(-321 °F) (-230 °F) (428 °F) (842 °F)
-20 °C
(-68 °F)
-40 °C
(-104 °F)

SITRANS LG270, Ambient temperature/process temperature curves

Siemens FI 01 · 2015 4/311


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG270, Process pressure/process temperature ( -196 … +450 °C/-321 … +842 °F version)

Process
Pressure

400 bar
(5800 psig)
380 bar
(5510 psig)
350 bar
(5070 psig)
320 bar
300 bar (4640 psig)
(4350 psig)

200 bar
(2900 psig)

4
100 bar
(1450 psig)

Process
0 °C 100 °C 200 °C 300 °C 400 °C 450 °C
Temperature
-200 °C -100 °C
(-328 °F) (-148 °F) (32 °F) (212 °F) (392 °F) (572 °F) (752 °F) (842 °F)

SITRANS LG270, Process pressure/process temperature curve

4/312 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

■ Dimensional drawings
LG Series plastic housing
69 86
(2.72) (3.39)
Ø 77 Ø 77
(3.03) (3.03)

M16x1.5

114 114
(4.49) (4.49)

M20x1.5/
½" NPT
Single chamber
version
M20x1.5/
½" NPT
Double chamber
version
4
LG Series aluminum housing
116 91
(4.57) (3.58)
Ø 84 Ø 84
(3.31) (3.31)

M16x1.5

120 124
(4.72) (4.88)

M20x1.5/
½" NPT M20x1.5

Single chamber M20x1.5/ Double chamber


version ½" NPT version

LG Series stainless steel housing

90
69 (3.54)
59 Ø 84
(2.72)
(2.32) Ø 77 (3.31)
Ø 80 (3.03)
(3.15)

M16x1.5

119 123
112
(4.69) (4.84)
(4.41)
M20x1.5/ M20x1.5/
½" NPT ½" NPT

M20x1.5/
Single chamber Single chamber Double chamber
½" NPT
version, version, version,
electropolished precision casting precision casting

Note: For integrated display and adjustment module the housing is 9 (0.35) higher for all housing options

SITRANS LG series, dimensions in mm (inch)

Siemens FI 01 · 2015 4/313


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG240

Cable version Ø 4 (0.157), PFA coated


(2.73) Rod version Ø 10 (0.394), PFA coated
69.4

(2.73)
(2.76)

69.4
(2.81)

(2.76)
71.4

(2.81)
70

71.4
70
4
(19.68 ... 12 598.42)

Cable version Cable version


500 ... 32 000

with clamp with bolting Cable version Cable version

(11.81... 157.48)
with clamp with bolting

300 ... 4 000


Ø4
(0.16)
(4.53)
115

Ø4 Ø 10
(0.16) (0.39)
Autoclaved version Rod version Ø 8 (0.315), polished
(4.84)
112

Cover with
(7.20)
183

(2.02)
Ø 54 groove nut
56

(2.13)
(2.57)
65.3

Groove nut

Process fitting
Øw
(11.81... 157.48)
300 ... 4 000
(11.81... 157.48)
300 ... 4 000

Øw

DIN DN 25 DN 32 DN 40/ 1" 1½" Ø 50.5


Ø8
DIN DN 50/ 2" Ø 64 (0.32)
DIN DN 65/ 3" Ø 91

SITRANS LG240, dimensions in mm (inch)

4/314 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG250
Rod version
Cable version with gravity weight

SW 36 (1.42")
SW 36 (1.42") (G3/4, 3/4" NPT)
(G3/4, 3/4" NPT) Cable version with centering SW 41 (1.61")
SW 41 (1.61") (G1, 1" NPT)
(G1, 1" NPT)
weight
SW 46 (1.81")
SW 55
SW 46 (1.81") (G1½, 1½" NPT)
(2.17)

(2.01)
SW 36 (1.42")

(1.81)
(1.81)
(G1½, 1½" NPT)

51
46
46

(G3/4, 3/4" NPT)

(3.78)
SW 41 (1.61")

96
G3/4, 3/4" NPT (G1, 1" NPT) G3/4, 3/4" NPT G1½,
1½" NPT

(0.87)
SW 46 (1.81")
(0.87)

G1, 1" NPT G1, 1" NPT

(1.18)
22
22

(G1½, 1½" NPT)

30
G1½, 1½" NPT G1½, 1½" NPT

(1.81)
(0.87)

46
22
(19.68 ... 2 952.75)
500 ... 75 000

(11.81 ... 236.22)


G3/4, 3/4" NPT

(11.81 ... 236.22)


(19.68 ... 2 952.75)

300 ... 6 000


(0.87)

300 ... 6 000


G1, 1" NPT

22
500 ... 75 000

G1½, 1½" NPT


Ø4 Ø4
4

(19.68 ... 2 952.75)


(0.16) (0.16)

500 ... 75 000


Ø2
(0.08)
(3.94)

(3.94)
100

100

Ø4
(1.97)
50

Ø2 (0.16)
Ø 16 Ø 16 Ø 16 (0.08)

(1.18)
(0.63) (0.63) (0.63) 30
Ø 20 Ø 20 Ø 20 Ø 12
Ø8
(0.79) (0.79) (0.79) (0.47)
(0.32)
(1.18)
30

Ø2 Ø4
(0.079) (0.157)

SITRANS LG250, dimensions in mm (inch)

SITRANS LG250, coax version

Coaxial version Coaxial version


ø 21.3 (0.839) ø 42.2 (1.661)

SW 36 (1.42)
(G¾, ¾" NPT)
SW 41 (1.61)
(G1, 1" NPT)
SW 46 (1.81) SW 55
(1.81)

(2.01)
46

(G1½, 1½" NPT)


51

(2.17)
G¾, ¾" NPT, G1½,
G1, 1" NPT, 1½" NPT
(0.86)
22

G1½, 1½" NPT


Up to 6 m (19.69 ft)

Up to 6 m (19.69 ft)

ø 21.3 ø 42.2
(0.84) (1.66)

SITRANS LG250, dimensions in mm (inch)

Siemens FI 01 · 2015 4/315


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG260
Cable version Ø 6 (0.236)/ Ø 11 (0.433)- PA coated

Rod version Ø 16 (0.63)


Cable version Ø 4 (0.157)/ Ø 6 (0.236)- PA coated
SW 55

(3.15)
2.17

80
G1½
SW 36 SW 55
Joint

(3.15)
1.42
(1.81)

2.17

(0.24)

80
46

cable

30
G 3/4
G1½

(19.68 ... 2 559.05)


Joint
(0.87)

500 ... 65 000

(0.24)
Joint rod
22

cable

30
(19.68 ... 2 559.05)

Ø6 Ø 11

(11.81 ... 236.22)


500 ... 65 000

(0.24) (0.43)

300 ... 6 000


4 Ø4
(0.16)
Ø6
(0.24)

(5.91)
150
(5.91)
150

Ø 11 Ø 16
Ø 22 (0.433)
(0.79) (0.63)
Ø4
(0.157)

SITRANS LG260, dimensions in mm (inch)

4/316 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG270
Cable version with gravity weight Cable version with centering weight

SW 60
SW 60

(12.28)
Max. height of
(9.33)
(2.36)

312

(12.28)
237

(2.36)

(9.33)
237

312
the vessel
insulation
Max. height of
the vessel
G1½
insulation
1½" NPT G1½
1½" NPT

(1.38)
35

(1.38)
(1.77)

35
4

45
(19.68 ... 2 362.20)

(19.68 ... 2 362.20)


(19.68 ... 2 362.20)

(19.68 ... 2 362.20)


500 ... 60 000

500 ... 60 000


500 ... 60 000

500 ... 60 000


Ø2
(0.08)/
Ø4 Ø4
Ø4
(0.16) (0.16) Ø2
Ø2 Ø2/ Ø4 (0.16)
(0.08)/

(1.18)

(1.18)

(1.18)
(0.08) (0.08) (0.16)

30

30

30
Ø4
(3.94)
(3.94)

100

(0.16)
100

(1.97)
50

Ø 16 Ø 16 Ø 16
(0.63) (0.63) (0.63)
Ø 20 Ø 20 Ø 20
(0.79) (0.79) (0.79)

Rod version

SW 60
(9.33)

(12.28)
237

(2.36)
312

Max. height of
the vessel
insulation
G1½
1½" NPT
(1.38)
(1.77)

35
45

(19.68 ... 236.22)


(11.81 ... 236.22)

500 ... 6 000


300 ... 6 000

Ø 16 Ø 16
(0.63) (0.63)

SITRANS LG270, dimensions in mm (inch)

Siemens FI 01 · 2015 4/317


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

SITRANS LG270, coax version


Temperature version Temperature version
-196 … +280 °C (-321 … 536 °F) -196 … +450 °C (-321 … 842 °F)

OXYUY_P
ZXYG
z~G]W

O`UZZP
YZ^G
OYUZ]P

OXUZ_P
Z\
nXÃIV
XÃIGuw{

OYUY[P
\^
4

Up to 6 m (19.69 ft)
Up to 6 m (19.69 ft)

þG[YUYGOXU]]P þG[YUYGOXU]]P

SITRANS LG270, dimensions in mm (inch)

4/318 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

■ Schematics
2-wire HART electronic option, electronics and connection 2-wire HART electronic option, electronics compartment,
compartment, single chamber housing double chamber housing
Internal
For display and
connection
For display and adjustment adjustment
to the plug
module or interface adapter module or
connector
interface
for external
For external display adapter
4-20mA display
4-20mA and adjustment unit and adjustment
Internal connection
to the connection unit (optional)
Voltage Ground terminal for (+) 1 2 (-) 5 6 7 8
compartment
supply, signal
(+) 1 2 (-) 5 6 7 8 connection of the
output cable screen

2-wire HART electronic option, connection compartment,


Note: All 2-wire HART connections and electronics are also
available with SIL
4
Ex-d-ia double chamber housing

4-20mA
Ground terminal for
connection of the
Voltage cable screen
(+) 1 2 (-)
supply, signal
output

SITRANS LG series, connections

4-wire HART electronic option, electronics compartment, 4-wire electronic option, connection compartment with
double chamber housing double chamber housing with mains voltage
For display and
adjustment
module or
interface adapter 4 ... 20mA
Common
Passive +

IS GND
Active +

4 ... 20mA Power Supply

Function ground
with installation
according
( +)1 2(-) 5 6 7 8 (+) 1 2 (-) 5 6 7 8 to CSA
RVs Mass - output
Internal connection to the TVu
connection compartment + 4…20 mA output (passive)
+ 4…20 mA output (active)

PE
Voltage
Supply

SITRANS LG series, connections

Siemens FI 01 · 2015 4/319


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

Supplementary electronics Connection compartment with low voltage

4...20mA

Common
Passive +

IS GND
Active +
I II
4 ... 20mA 4 ... 20mA Power Supply

Function ground
with installation
(+) 1 2 (-) (+) 7 8 (-) (+) 1 2 (-) 5 6 7 8 according to CSA

+ RVs Mass - output


1 2 /N 4 … 20 mA output (passive)
+ +
+ 4 … 20 mA output (active)

Voltage
1 First current output (I) - Voltage supply and signal output (HART) supply
2 Second current output (II) - Voltage supply and signal output

4
(without HART)

SITRANS LG series, connections

Modbus electronic option, connection compartment Modbus electronic option,


electronics compartment, double chamber housing For display and
USB adjustment
interface module or
interface
USB MODBUS
adapter
IS GND
D1 (-)
D0 (+)

Slide switch
power supply for integrated 4 ... 20 mA
termination
resistor
(120 Ω)

(+)1 2(-) off on 3 4 5 (+) 1 2 (-) 5 6 7 8


Modbus Voltage
signal supply 1 1

1 Internal connection to the connection compartment

SITRANS LG series, connection

Profibus electronic option, connection compartment, Profibus electronic option, electronics compartment,
double chamber housing double chamber housing

2
2
3

01 01
6 78 9

6 78 9
23 4

23 4

5 5
Bus Bus

(+)1 2(-) (+)1 2(-) 5 6 7 8

3 1 1
1 R
T

1 Voltage supply, signal output 1 Internal connection to the connection compartment


2 For display and adjustment module or interface adapter 2 Contact pins for the display and adjustment module or interface adapter

3 Ground terminal for connection of the cable screen 3 Selection switch for bus address

LG series, connection

4/320 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement - Guided wave radar transmitters
SITRANS LG series

Profibus electronic option, electronics and connection compartment,


single chamber housing

2
3
0 01 01
6 789

6 789
23 4

23 4
1
1

5 5
Bus 0
4

(+)1 2(-) 5 6 7 8 5

1 Voltage supply, signal output


2 For display and adjustment module or interface adapter

4
3 Selection switch for bus address
4 For external display and adjustment unit
5 Ground terminal for connection of the cable screen

LG series, connection

Siemens FI 01 · 2015 4/321


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

■ Overview ■ Configuration
Installation

Build up of material in active shield Mounting on a bypass


area does not affect switch
operation.

4
SITRANS LC300 is an inverse frequency shift capacitance
continuous level transmitter for liquids and solids applications.
It is ideal for standard industrial applications in chemical, hydro-
carbon processing, food and beverage, water, wastewater,
and mining, aggregate, and cement industries.

■ Benefits

M
in
• Active-Shield technology so measurement is unaffected by

.5
0
material buildup in active shield section

(2
)
• Highly accurate and reliable PFA-lined probes
• Integrated local LCD display
• 2-wire (4 to 20 mA) current loop design
• Current signaling according to NAMUR NE 43
Min. 50 (2)
• Push-button calibration and programming
Install probe at least 50 (2) from tank wall.
• Stilling well (ground tube) version for low dielectric media and Note angle of repose and adjust accordingly.
non-metallic vessels

■ Application SITRANS LC300 installation, dimensions in mm (inch)

SITRANS LC300 is a 2-wire level measurement instrument com-


bining a sophisticated, yet easy-to-adjust microprocessor with
field-proven probes. It is available in four versions: rod, rod with
stilling well, cable with PFA insulation, and cable without
PFA insulation.
Materials with low or high dielectric properties are accurately
measured and Active-Shield technology helps in ignoring the ef-
fects of buildup or condensation near vessel nozzle.
• Key Applications: Conductive and non-conductive media
including: liquids and solids in standard industrial processes,
bulk solids applications involving dust, and chemical
processes involving vapor

4/322 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

■ Technical specifications
Input Safety
Measuring range 1.66 ... 3 300 pF Measurement current signaling According to NAMUR NE 43,
signal 3.8 ... 20.5 mA, fault  3.6 or
Span Min. 3.3 pF  21 mA (22 mA)
Output Certificates and approvals
Loop current Continuous signal 4 ... 20 mA/ General CE, CSAUS/C, FM, RCM
20 ... 4 mA according to NAMUR 43
Dust Ignition Proof
Accuracy (transmitter) (Intrinsically Safe probe circuit)
Temperature stability 0.25 % of actual capacitance value • Canada/USA FM/CSA:
Class II, Div. 1, Groups E,F,G
Non-linearity and repeatability < 0.4 % of full scale and actual mea- Class III T4
surement value
• Europe ATEX 1/2 D T100 °C
Accuracy Deviation < 0.5 % of actual measure-
ment value Flame Proof
(Intrinsically Safe probe circuit)
1)
Rated operating conditions • Europe ATEX II 1/2 G EEx d [ia] IIC T6 ... T1

4
Ambient conditions ATEX II 1/2 D T100 °C
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) Explosion Proof
• Installation category I (Intrinsically Safe probe circuit)
• Pollution degree 4 • Canada/USA Class I, Div. 1, Groups A,B,C,D
Class II, Div. 1, Groups E,F,G
• Ingress protection Type 4/NEMA 4/IP65 (optional IP68)
Class III T4
Installation conditions
Marine Bureau Veritas Type Approval ABS
• Location Indoor/outdoor Type Approval
Process pressure -1 ... +35 bar g (-14.6 ... +511 psi g) Overfill Protection AIB-Vincotte
Process temperature -40 ... +200 ºC (-40 ... +392 ºF)3) Other Pattern Approval (China)
Min. dielectric constant r 1.5 1)
When operation is in areas classified as hazardous, observe restrictions
Design according to relevant certificate.
See also Pressure/Temperature curves on page 4/331.
Material 2)
• Enclosure Aluminum, epoxy-coated Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
Probe diameter 3)
Not suitable for steam environments
• Rod version 19 mm (0.75 inch) with PFA jacket
• Cable version 9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA jacket Design: Probe Rod version Stilling well Cable version
version
Active shield length
Length Min. 300 mm Min. 300 mm Min. 1 000 mm
• Rod version Threaded: 120 mm (4.72 inch) (12 inch), (12 inch), (40 inch),
Flanged: 100 mm (3.94 inch) max. 5 000 mm max. 5 000 mm max. 25 000 mm
• Cable version Threaded: 125 mm (4.92 inch) (197 inch) (197 inch) (984 inch)
Flanged: 105 mm (4.13 inch)
Sensor wetted PFA, 316L PFA, 316L 316L stainless
Process connection of probe parts stainless steel stainless steel steel or 316L
• Threaded rod mounting ¾",1",1¼", 1½" NPT [(Taper), stainless steel
ANSI/ASME B1.20.1] with PFA insula-
tion
R ¾",1", 1½" [(BSPT),
EN 10226/PT (JIS-T), JIS B 0203] O-ring seal mate- FKM or FFKM FKM or FFKM FKM or FFKM
G ¾",1", 1½" [(BSPP), rial
EN ISO 228-1/PF (JIS-P), JIS B 0202] Thermal isolator Optional Optional Optional
• Threaded cable mounting 1½" NPT [(Taper),
ANSI/ASME B1.20.1] Options N/A N/A Mounting eye for
R 1½" [(BSPT), PFA insulated
EN 10226/PT (JIS-T), JIS B 0203] cable version
G 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P), JIS B 0202]
• Flange mounting 1 ... 4" ASME, DN 25 ... 100
Enclosure cable inlet 2 x ½" NPT or 2 x M20x1.5
Power supply 12 ... 30 V DC any polarity,
2-wire current loop circuit
User Interface
Display Local LCD, 4 digit, each 0 ... 9 and
limited alpha characters

Siemens FI 01 · 2015 4/323


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC300, rod version 7ML5670- SITRANS LC300, rod version 7ML5670-
An inverse frequency shift capacitance continuous 77 7 77 - 777 0 An inverse frequency shift capacitance continuous 77 7 77 - 777 0
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Click on the Article No. for the online configura- Wetted seals
tion in the PIA Life Cycle Portal. FKM 0
Process connection FFKM [for process temperatures above -20 °C 1
Threaded, 316L stainless steel (-4 °F)]
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0A Probe material
1" NPT [(Taper), ANSI/ASME B1.20.1] 0B 19 mm (0.75 inch) diameter 316L stainless steel, 0
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0C PFA lined rod
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0D Approvals
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1A General Safety (CSA, FM, CE, RCM) A
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1B Dust Ignition Proof With IS Probe B
R 1½" [(BSPT), EN 10226/PT (JIS-T), 1D CE, RCM, ATEX II 1/2 D T100 °C
JIS B 0203] Flame Proof Enclosure With IS Probe C

4
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3A ATEX II 1/2 D T100 °C
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3B Dust Ignition Proof With IS Probe D
JIS B 0202] CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3D
JIS B 0202] Explosion Proof Enclosure With IS Probe E
CSA/FM Class I, Div. 1, Groups A, B, C, D
Welded flange, 316L stainless steel, raised face1) CSA/FM Class II, Div. 1, Groups E, F, G
1" ASME, 150 lb 5A CSA/FM Class III T4
1" ASME, 300 lb 5B
Enclosure
1" ASME, 600 lb 5C
Aluminum epoxy coated 2 x ½" NPT via adapter - A
1½" ASME, 150 lb 5D cable inlet, IP65
1½" ASME, 300 lb 5E Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B
1½" ASME, 600 lb 5F IP65
Aluminum epoxy coated 2 x ½" NPT via adapter - C
2" ASME, 150 lb 5G cable inlet, IP68
2" ASME, 300 lb 5H
2" ASME, 600 lb 5J Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D
IP68
3" ASME, 150 lb 5K
1)
3" ASME, 300 lb 5L Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
3" ASME, 600 lb 5M
4" ASME, 150 lb 5N
4" ASME, 300 lb 5P
4" ASME, 600 lb 5Q
Welded flange, 316L stainless steel,
Type A flat faced1)
DN 25, PN 16 6A
DN 25, PN 40 6B
DN 40, PN 16 6C
DN 40, PN 40 6D
DN 50, PN 16 6E
DN 50, PN 40 6F
DN 80, PN 16 6G
DN 80, PN 40 6H
DN 100, PN 16 6J
DN 100, PN 40 6K

Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
300 ... 1 000 mm (11.81 ... 39.37 inch) A
1 001 ... 2 000 mm (39.41 ... 78.74 inch) B
2 001 ... 3 000 mm (78.78 ... 118.11 inch) C
3 001 ... 4 000 mm (118.15 ... 157.48 inch) D
4 001 ... 5 000 mm (157.52 ... 196.85 inch) E
Thermal isolator
Without thermal isolator 0
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]

4/324 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's Test Certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Operating Instructions Article No.
English 7ML1998-5HE03
French 7ML1998-5HE11
German 7ML1998-5HE33
Spanish 7ML1998-5HE21 4
Multi-language Quick Start manual A5E32268590
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Electronic transmitter kit (includes transmitter and 7ML1830-1KN
driver)
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section

Siemens FI 01 · 2015 4/325


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC300, stilling well version 7ML5671- SITRANS LC300, stilling well version 7ML5671-
An inverse frequency shift capacitance continuous 77 7 77 - 777 0 An inverse frequency shift capacitance continuous 77 7 77 - 777 0
level transmitter for liquid applications. level transmitter for liquid applications.
Click on the Article No. for the online configura- Dust Ignition Proof With IS Probe D
tion in the PIA Life Cycle Portal. CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Process connection
Explosion Proof Enclosure With IS Probe E
Threaded, 316L stainless steel CSA/FM Class I, Div. 1, Groups A, B, C, D
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0D CSA/FM Class II, Div. 1, Groups E, F, G
R 1½" [(BSPT), EN 10226/PT (JIS-T), 1D CSA/FM Class III T4
JIS B 0203]
Enclosure
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3D
JIS B 0202] Aluminum epoxy coated 2 x ½" NPT via adapter - A
cable inlet, IP65
Welded flange, 316L stainless steel, raised face1)
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B
1½" ASME, 150 lb 5D IP65
1½" ASME, 300 lb 5E Aluminum epoxy coated 2 x ½" NPT via adapter - C

4
1½" ASME, 600 lb 5F cable inlet, IP68
2" ASME, 150 lb 5G Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D
2" ASME, 300 lb 5H IP68
2" ASME, 600 lb 5J 1) Flange bolting patterns and facings dimensionally correspond to the
3" ASME, 150 lb 5K applicable ASME B16.5 or EN 1092-1 standard.
3" ASME, 300 lb 5L
3" ASME, 600 lb 5M Selection and Ordering data Order code
4" ASME, 150 lb 5N Further designs
4" ASME, 300 lb 5P Please add "-Z" to Article No. and specify Order
4" ASME, 600 lb 5Q code(s).
Welded flange, 316L stainless steel,
Insertion length, specify in plain text: Y01: ... mm Y01
Type A flat faced1)
DN 40, PN 16 6C Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
DN 40, PN 40 6D Measuring-point number/identification
(max. 27 characters) specify in plain text
DN 50, PN 16 6E
Manufacturer's Test Certificate: M to DIN 55350, C11
DN 50, PN 40 6F Part 18 and to ISO 9000
DN 80, PN 16 6G
DN 80, PN 40 6H Inspection Certificate Type 3.1 per EN 10204 C12

DN 100, PN 16 6J Operating Instructions Article No.


DN 100, PN 40 6K English 7ML1998-5HE03
Probe Length French 7ML1998-5HE11
(from flange face or including process thread)
German 7ML1998-5HE33
Add Order code Y01 and plain text:
"Insertion length ... mm" Spanish 7ML1998-5HE21
300 ... 1 000 mm (11.81 ... 39.37 inch) A Multi-language Quick Start manual 7ML1998-5QH81
1 001 ... 2 000 mm (39.41 ... 78.74 inch) B Note: The Operating Instructions should be
2 001 ... 3 000 mm (78.78 ... 118.11 inch) C ordered as a separate line item on the order.
3 001 ... 4 000 mm (118.15 ... 157.48 inch) D This device is shipped with the Siemens Milltronics
4 001 ... 5 000 mm (157.52 ... 196.85 inch) E manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Thermal isolator
Accessories
Without thermal isolator 0
With thermal isolator [for process connection 1 Electronic transmitter kit 7ML1830-1KN
temperatures over 85 °C (185 °F)] (includes transmitter and driver)
Wetted seals SITRANS RD100, loop powered display - 7ML5741-...
FKM 0 see Chapter 7
FFKM [for process temperatures above -20 °C (-4 °F)] 1 SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
Probe material
35 mm (1.38 inch) diameter stilling well, 1 SITRANS RD300, dual line display with totalizer 7ML5744-...
with 19 mm (0.75 inch) diameter 316L and linearization curve and Modbus conversion -
stainless steel, PFA lined rod with PTFE spacers see Chapter 7
Approvals SITRANS RD500 web, universal remote monitoring 7ML5750-...
General Safety (CSA, FM, CE, RCM) A solution for instrumentation - see Chapter 7
Dust Ignition Proof With IS Probe B For applicable back up point level switch -
CE, RCM, ATEX II 1/2 D T100 °C see point level measurement section
Flame Proof Enclosure With IS Probe C
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6 ... T1,
ATEX II 1/2 D T100 °C

4/326 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC300, cable version 7ML5672- SITRANS LC300, cable version 7ML5672-
An inverse frequency shift capacitance continuous 77 7 77 - 777 0 An inverse frequency shift capacitance continuous 77 7 77 - 777 0
level transmitter for non-conductive liquids and level transmitter for non-conductive liquids and
solids applications. solids applications.
Click on the Article No. for the online configura- Approvals
tion in the PIA Life Cycle Portal. General Safety (CSA, FM, CE, RCM) A
Process connection Dust Ignition Proof With IS Probe B
Threaded, 316L stainless steel CE, RCM, ATEX II 1/2 D T100 °C
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0D Flame Proof Enclosure With IS Probe C
CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
R 1½" [(BSPT), EN 10226/PT (JIS-T), 1D ATEX II 1/2 D T100 °C
JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3D Dust Ignition Proof With IS Probe D
JIS B 0202] CSA/FM Class II, Div. 1, Groups E, F, G
Welded flange, 316L stainless steel, raised face1) CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe E
1½" ASME, 150 lb 5D CSA/FM Class I, Div. 1, Groups A, B, C, D

4
1½" ASME, 300 lb 5E CSA/FM Class II, Div. 1, Groups E, F, G
1½" ASME, 600 lb 5F CSA/FM Class III T4
2" ASME, 150 lb 5G Enclosure
2" ASME, 300 lb 5H Aluminum epoxy coated 2 x ½" NPT via adapter - A
2" ASME, 600 lb 5J cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B
3" ASME, 150 lb 5K IP65
3" ASME, 300 lb 5L Aluminum epoxy coated 2 x ½" NPT via adapter - C
3" ASME, 600 lb 5M cable inlet, IP68
4" ASME, 150 lb 5N Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D
4" ASME, 300 lb 5P IP68
4" ASME, 600 lb 5Q 1)
Flange bolting patterns and facings dimensionally correspond to the
Welded flange, 316L stainless steel, applicable ASME B16.5 or EN 1092-1 standard.
Type A flat faced1) 2)
Cable lengths from 15 000 mm (590.55 inch) to 25 000 mm (984.25 inch)
DN 40, PN 16 6C can be used in non-conductive media. Contact Factory for assistance.
DN 40, PN 40 6D
DN 50, PN 16 6E
DN 50, PN 40 6F
DN 80, PN 16 6G
DN 80, PN 40 6H
DN 100, PN 16 6J
DN 100, PN 40 6K
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch) A
2 001 ... 4 000 mm (78.78 ... 157.48 inch) B
4 001 ... 6 000 mm (157.52 ... 236.22 inch) C
6 001 ... 8 000 mm (236.26 ... 314.96 inch) D
8 001 ... 10 000 mm (315.00 ... 393.70 inch) E
10 001 ... 12 000 mm (393.74 ... 472.44 inch) F
12 001 ... 14 000 mm (472.48 ... 551.18 inch) G
14 001 ... 16 000 mm (551.22 ... 629.92 inch)2) H
16 001 ... 18 000 mm (629.96 ... 708.66 inch)2) J
18 001 ... 20 000 mm (708.70 ... 787.40 inch)2) K
20 001 ... 22 000 mm (787.44 ... 866.14 inch)2) L
22 001 ... 24 000 mm (866.18 ... 944.88 inch)2) M
24 001 ... 25 000 mm (944.92 ... 984.25 inch)2) N
Thermal isolator
Without thermal isolator 0
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]
Wetted seals
FKM 0
FFKM [for process temperatures above 1
-20 °C (-4 °F)]
Probe material
Bare 316L stainless steel cable and 316L 0
stainless steel cable weight, tinned copper crimp,
PTFE backing ring, PEEK isolator and PFA lined
active shield

Siemens FI 01 · 2015 4/327


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's Test Certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Operating Instructions Article No.
English 7ML1998-5HE03
French 7ML1998-5HE11
German 7ML1998-5HE33
4 Spanish 7ML1998-5HE21
Multi-language Quick Start manual 7ML1998-5QH81
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Electronic transmitter kit (includes transmitter 7ML1830-1KN
and driver)
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section

4/328 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC300, PFA coated cable version 7ML5673- SITRANS LC300, PFA coated cable version 7ML5673-
An inverse frequency shift capacitance continuous 77 7 77 - 777 7 An inverse frequency shift capacitance continuous 77 7 77 - 777 7
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Click on the Article No. for the online configura- Probe material
tion in the PIA Life Cycle Portal. PFA coated cable and 316L stainless steel cable 1
Process connection weight, PEEK isolator and PFA lined active shield
Threaded, 316L stainless steel Approvals
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0D General Safety (CSA, FM, CE, RCM) A
R 1½" [(BSPT), EN 10226/PT (JIS-T), 1D Dust Ignition Proof With IS Probe B
JIS B 0203] CE, RCM, ATEX II 1/2 D T100 °C
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3D Flame Proof Enclosure With IS Probe C
JIS B 0202]
Welded flange, 316L stainless steel, raised face1) CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
1½" ASME, 150 lb 5D
Dust Ignition Proof With IS Probe D
1½" ASME, 300 lb 5E CSA/FM Class II, Div. 1, Groups E, F, G

4
1½" ASME, 600 lb 5F CSA/FM Class III T4
2" ASME, 150 lb 5G Explosion Proof Enclosure With IS Probe E
2" ASME, 300 lb 5H CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
2" ASME, 600 lb 5J CSA/FM Class III T4
3" ASME, 150 lb 5K Enclosure
3" ASME, 300 lb 5L Aluminum epoxy coated 2 x ½" NPT via adapter - A
3" ASME, 600 lb 5M cable inlet, IP65
4" ASME, 150 lb 5N Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B
4" ASME, 300 lb 5P IP65
4" ASME, 600 lb 5Q Aluminum epoxy coated 2 x ½" NPT via adapter - C
cable inlet, IP68
Welded flange, 316L stainless steel,
Type A flat faced1) Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D
DN 40, PN 16 6C IP68
DN 40, PN 40 6D Mounting eye
DN 50, PN 16 6E Without Mounting eye 0
DN 50, PN 40 6F With mounting eye 1
DN 80, PN 16 6G 1) Flange bolting patterns and facings dimensionally correspond to the
DN 80, PN 40 6H applicable ASME B16.5 or EN 1092-1 standard.
2) Cable lengths from 15 000 mm (590.55 inch) to 25 000 mm (984.25 inch)
DN 100, PN 16 6J
can be used in non-conductive media. Contact Factory for assistance.
DN 100, PN 40 6K
Probe Length
(from flange face or including process thread)
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 000 ... 2 000 mm (39.37 ... 78.74 inch) A
2 001 ... 4 000 mm (78.78 ... 157.48 inch) B
4 001 ... 6 000 mm (157.52 ... 236.22 inch) C
6 001 ... 8 000 mm (236.26 ... 314.96 inch) D
8 001 ... 10 000 mm (315.00 ... 393.70 inch) E
10 001 ... 12 000 mm (393.74 ... 472.44 inch) F
12 001 ... 14 000 mm (472.48 ... 551.18 inch) G
14 001 ... 16 000 mm (551.22 ... 629.92 inch)2) H
16 001 ... 18 000 mm (629.96 ... 708.66 inch)2) J
18 001 ... 20 000 mm (708.70 ... 787.40 inch)2) K
20 001 ... 22 000 mm (787.44 ... 866.14 inch)2) L
22 001 ... 24 000 mm (866.18 ... 944.88 inch)2) M
24 001 ... 25 000 mm (944.92 ... 984.25 inch)2) N
Thermal isolator
Without thermal isolator 0
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]
Wetted seals
FKM 0
FFKM [for process temperatures above -20 °C 1
(-4 °F)]

Siemens FI 01 · 2015 4/329


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300
Selection and Ordering data Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Manufacturer's Test Certificate: M to DIN 55350, C11
Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Operating Instructions Article No.
English 7ML1998-5HE03
French 7ML1998-5HE11
German 7ML1998-5HE33
4 Spanish 7ML1998-5HE21
Multi-language Quick Start manual 7ML1998-5QH81
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the ATEX Quick Start and
Operating Instructions library.
Accessories
Electronic transmitter kit (includes transmitter 7ML1830-1KN
and driver)
SITRANS RD100, loop powered display - 7ML5741-...
see Chapter 7
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section

4/330 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

■ Characteristic curves
Pressure/temperature curve
LC300 standard, extended rod and cable probes
Threaded process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

4
10 bar (145 psi)
Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
ermitted operating pressure = 30 bar (435 psi) at 75 °C

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5625)

Siemens FI 01 · 2015 4/331


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

Pressure/temperature curve
LC300 standard, extended rod and cable probes
ASME flanged process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)

Permitted operating pressures P

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

4 50 bar (725 psi)


ASME 6001)

40 bar (580 psi)

30 bar (435 psi)


ASME 3001)

20 bar (290 psi)

10 bar (145 psi) ASME 1501)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)

Pressure/temperature curve
LC300 standard, extended rod and cable probes
EN flanged process connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

10 bar (145 psi) PN 161)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)

4/332 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

■ Dimensional drawings
Threaded (7ML5670) Threaded (7ML5671)

Lid
Lid clip
2 cable entries
Electronics/ 1/2" NPT or
enclosure 20 (0.79) M20 x 1.5
M20: 135 (5.32)
Y02 1)

Y02 1)
1/2" NPT: 150
(5.91)
Lid without window
min. = 300 (14) / max. = 5 000 (197)

Stainless steel
stilling well

min. = 300 (14) / max. = 5 000 (197)


Y01 (insertion length)

Vent

(5.91)

275 (10.83)
150
4

Y01 (insertion length)


Measuring length
Measuring length

PFA
insulated Thermal
probe isolator
PFA
insulated
probe

Ø19 (0.75) Note:


1) Rod version Y02: Shield length = 100 mm
(3.9 inch) for threaded including process
connection thread length, 100 mm
*
*

(3.9 inch) for welded flange


Ø19 (0.75) Ø35 (1.38) 2) For non-conductive applications only.
Non-insulated cable can be shortened on
* = 30 (1.18) Inactive tip site. Weight is included in measuring
length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
2) 3) Weight is not included in measuring
Cable version, non-insulated Cable version, insulated length.
Threaded (7ML5672) Threaded (7ML5673) 4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
20 (0.79)
Y02 =

Y02 =
(4.13)

(4.13)
105

105
min. = 1 000 (40) / max. = 25 000 (984)

min. = 1 000 (40) / max. = 25 000 (984)

Ø9 (0.35)

See
Y01 (insertion length)

Y01 (insertion length)


Measuring

note 4
length

350 (13.78)

PFA insulated
Stainless steel
cable
Measuring length

cable
Ø9 (0.35)
Ø34,5 (1.36)
Ø6 (0.24)
Stainless steel
weight (electrically
350 (13.78)

Mounting eye
250 (9.84)

Stainless steel isolated but not


weight, actual PFA insulated), Ø12
20 (0.79)

weight = (1.27 kg actual weight = (0.47)


[2.80 lb]) (2.15 kg [4.76 lb]) Ø25 (0.98)

Ø32 (1.26) Ø34,5 (1.36)

SITRANS LC300 - Threaded Process Connections, dimensions in mm (inch)

Siemens FI 01 · 2015 4/333


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

Welded Flange (7ML5670) Welded Flange (7ML5671)

2 cable entries
Lid ½" NPT or
Lid clip
M20 x 1.5
Electronics/
M20: 135 (5.32)
enclosure
1/2" NPT: 150 (5.91)

Lid without window

Y02 1)
Y02 1)

min. = 300 (14) / max. = 5 000 (197)

Stainless steel

(5.91)
stilling well

150

275 (10.83)
min. = 300 (14) / max. = 5 000 (197)
Y01 (insertion length)

Vent

Y01 (insertion length)


Thermal

Measuring length
isolator
Measuring length

4
PFA
insulated
probe PFA
insulated Flange Facing (raised face)
probe
Flange Class Facing thickness
Ø19 (0.75) ASME 150/300 2 (0.08)
ASME 600/900 7 (0.28)
PN16/40 2 (0.08)
*
*

Notes:
Ø19 (0.75) Ø35 (1.38) 1) Rod version Y02: Shield length = 100 mm
(3.9 inch) for threaded including process
* = 30 (1.18) inactive tip connection thread length, 100 mm
(3.9 inch) for welded flange.
2) For non-conductive applications only.
Non-insulated cable can be shortened on
Cable version, non-insulated 2) Cable version, insulated 3) site. Weight is included in measuring
Welded Flange (7ML5672) Welded Flange (7ML5673) length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
Weight is not included in measuring
length.
4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
Y02 =

Y02 =
(4.13)

(4.13)
105

105
min. = 1 000 (40) / max. = 25 000 (984)

min. = 1 000 (40) / max. = 25 000 (984)

See Ø9 (0.35)
Measuring
Y01 (insertion length)

Y01 (insertion length)

note 4
length

PFA insulated
Stainless steel
cable
350 (13.78)
Measuring length

cable
Ø9 (0.35)
Ø6 (0.24)
Ø34,5 (1.36)
350 (13.78)
250 (9.84)

Stainless steel Mounting eye


weight (electrically
Stainless steel Ø12
20 (0.79)

isolated but not PFA


weight insulated) (0.47)
Ø25 (0.98)

Ø32 (1.26) Ø34,5 (1.36)

SITRANS LC300 - Flanged Process Connections, dimensions in mm (inch)

4/334 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300

■ Schematics
With safety barrier Without safety barrier
white (S) orange (S)
black (O) black (O)
red (+) red (+)

4 ... 20 mA (2-wire) current loop


measurement signal (not polarity
sensitive)
For factory software

4
update use only

Menu / function selector Down / - button


Up / + button

SITRANS LC300 connections

Siemens FI 01 · 2015 4/335


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

■ Overview ■ Configuration
Installation

Build up of material or condensation in active shield area


does not affect switch operation.

4
SITRANS LC500 is an inverse frequency shift capacitance level
or interface transmitter for extreme and critical process condi-
tions, such as oil and liquified natural gas (LNG) as well as toxic
and aggressive chemicals and vapors.

■ Benefits
• Active-Shield technology so measurement is unaffected by
material buildup in active shield section Mounting on non-linear vessels in non-conductive fluids
• Simple push-button calibration and integrated local display using stilling well.
• Inverse frequency approach provides high resolution
• 2-wire loop powered 4 to 20/20 to 4 mA measurement signal SITRANS LC500 installation, dimensions in mm (inch)
• Pre-detection alarm and full function diagnostics
• High temperature and pressure resistant (optional) ■ Technical specifications
• Full-function diagnostics comply with NAMUR NE 43 Input
• Easy calibration locally or via HART (using SIMATIC PDM Measuring range 1 ... 3 300 pF
software)
Span Min. 3.3 pF

■ Application Output
Solid-state switch
SITRANS LC500’s advanced electronics provide one-step,
• Output Galvanically isolated
push-button calibration and local display for easy on-site instal-
lation and setup. • Protection Bipolar

The unique mechanical probe design coupled with a high • Max. switching voltage • 30 V (DC)
• 30 V peak (AC)
performance transmitter gives superior performance in toxic
and aggressive chemicals, acids, caustics, adhesives and in • Max. load current 82 mA
viscous conductive and non-conductive materials. • Voltage drop < 1 V, typical at 50 mA
The SMART 2-wire transmitter has HART communications for re- • Time delay (pre or post switching) 1 ... 60 s
mote commissioning and inspection. Loop current 3.6 ... 22 mA/22 ... 3.6 mA
• Key Applications: Oil/water or foam/liquid interface (2-wire current loop)
measurement in separators or coalescers, cryogenic applica- Accuracy (transmitter)
tions including C02 and liquified natural gas (LNG), distillation/
Temperature stability 0.15 pF (0 pF) or < 0.25 %
regeneration tanks with high temperatures (typically < 0.1 %) of actual mea-
sured value, whichever is greater
over the full temperature range
Non-linearity and repeatability < 0.1 % of range and actual
measured value respectively
Accuracy Deviation < 0.1 % of measured value

4/336 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Rated operating conditions1) Power supply 12 ... 33 V DC
Installation conditions User Interface
• Location Indoor/outdoor Display Local LCD, 4 digit, each 0 ... 9 and
limited alpha characters
Ambient conditions
Rotary function switch For selecting programmable menu
• Ambient temperature (transmitter) -40 ... +85 °C (-40 ... +185 °F)2) items
• Installation category II Push buttons Red +, blue -, used in conjunction
• Pollution degree 4 with rotary switch for
programming
Medium conditions
Features
• Relative dielectric constant r Min. 1.5
Measurement current signaling According to NAMUR NE 43,
• Process temperature Temperature rating of process seal is signal 3.8 ... 20.5 mA, fault  3.6 or
pressure dependent.  21 mA (22 mA)
See Pressure/Temperature curves on
page 4/346. Safety • Inputs/outputs fully galvanically
isolated
3)
- Standard (PFA) -50 ... +200 °C (-58 ... +392 °F) • Polarity-insensitive current loop
• Fully potted
- Cryogenic version -200 ... +200 °C (-328 ... +392 °F)

4
• Integrated safety barrier
Contact ceg.smpi@siemens.com for
details. Diagnostics with fault alarm when: Primary variable (PV) out of limits,
system failure in measurement circuit,
• Process pressure Pressure rating of process seal is deviation between A/D and D/A con-
temperature dependent. verter, check sum, watch dog and
See Pressure/Temperature curves on self-checking facility
page 4/346.
Function rotary switch Positions 0 ... 9, A ... F
• Standard (PFA) -1 ... 150 bar g (2175 psi g)
SMART communication Conforming to HART Communication
Design Foundation (HCF)
Material Certificates and approvals
• Wetted parts material General Purpose CE, CSA, FM, RCM
- Standard rod 316L stainless steel
Non-incendive/Non-sparking • CSA/FM Class 1, Div. 2, Groups A,
• Probe insulation (rod) PFA B, C, D T4 ATEX II 3G 2D EEx nA [ib]
316 stainless steel/ IIC
• Cable
316 stainless steel PFA • T6 ... T4 T100 °C
Probe diameter Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
(Intrinsically Safe Probe Circuit) Groups E, F, G
• Rod version 16 mm (0.63 inch) or 24 mm
(0.95 inch) • ATEX II 1/2 GD EEx d [ia] T6 to T1
T100 °C
• Cable version 9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA jacket Explosion Proof • FM Class 1, Div. 1, Groups A, B, C, D
(Intrinsically Safe Probe Circuit) T4
Active shield length
• ATEX II 1/2 GD EEx d [ia] IIC T6 to T1
• Minimum (rod version) 50 mm (1.97 inch), customer select-
able (order number Y02) Marine Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3 and
Probe length ENV5, Bureau Veritas
• Rod version Max. 3.5 m (138 inch) with 16 mm 1)
When operation is in areas classified as hazardous, observe restrictions
rod, PFA according to relevant certificate. See also Pressure/Temperature curves on
Max. 5.5 m (216 inch) with 24 mm page 4/346.
rod, PFA 2)
Thermal isolator is used if process connection temperature exceeds 85 °C
• Cable version Max. 35 m (1 378 inch) (185 °F).
3)
Process connection of probe Not recommended for steam environments
• Threaded mounting NPT [(Taper), ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/
PF (JIS-P), JIS B 0202]
• Flange mounting ASME, EN 1092-1
Enclosure
• Material Aluminum, epoxy-coated
• Cable inlet 2 x ½ inch NPT (2 x M20x1.5,
IP68 adapter, optional)
• Degree of protection Type 4X/NEMA4X/IP65, IP68

Siemens FI 01 · 2015 4/337


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
SITRANS LC500 probe version Standard Extended Cable version with
Rod Sensor
Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange
Threaded Available as standard – Available as standard
Flange Available as standard Available as standard Available as standard
Process connection materials
Stainless steel 316L Available as standard Available as standard Available as standard
Probe insulation
PFA Available as standard Available as standard Available as standard
Length and Process parameters1)
Rod length for PFA 16 mm version Min. 200 mm (7.87 inch) Min. 200 mm (7.87 inch) Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch) Max. 3 500 mm (137.80 inch) Max. 3 500 mm (137.80 inch)
Rod length for PFA 24 mm version Min. 200 mm (7.87 inch) Min. 200 mm (7.87 inch) Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch) Max. 5 500 mm (216.54 inch) Max. 5 500 mm (216.54 inch)
Cable length Min. 1 000 mm (39.37 inch) Min. 1 000 mm (39.37 inch) Min. 5 000 mm (196.85 inch)2)

4 Maximum process pressure


Max. 35 000 mm (1 377.95 inch) Max. 35 000 mm (1 377.95 inch)
See Pressure/Temperature curves for specific probe type
Max. 35 000 mm (1 377.95 inch)2)
5 bar g (73 psi g)
Maximum process temperature 100 °C (212 °F)
1)
See Pressure/Temperature curves for specific probe type
2)
Refers to total insertion length. See dimension drawing on page 4/354 for further explanation - Not available as standard

4/338 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC500, Threaded or Welded Flange 7ML5513- SITRANS LC500, Threaded or Welded Flange 7ML5513-
with Cable Sensor with Cable Sensor
Inverse frequency shift capacitance level and 77 7 77 - 77 77 Inverse frequency shift capacitance level and 7 7 7 77 - 77 7 7
interface transmitter for extreme and critical interface transmitter for extreme and critical
process conditions, such as oil and liquid gas, process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours. toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configura- Approvals
tion in the PIA Life Cycle Portal. General Purpose: CE, CSA, FM, RCM 1
Version1) CSA / FM Class I, Div. 2, Groups A, B, C, D 2
Cable, 9 mm (0.35 inch) diameter, 316 stainless CSA / FM Class II, III, Div. 1, Groups E, F, G T4
steel with PFA insulation, weighted ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
Add Order code Y01 and plain text: ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C 4
"Insertion length ... mm" FM Class I, Div.1, Groups A, B, C, D, T4 6
1 000 ... 2 000 mm (39.37 ... 78.74 inch) 0E
Enclosure/Cable inlet
2 001 ... 4 000 mm (78.78 ... 157.48 inch) 1E Aluminum epoxy coated
4 001 ... 6 000 mm (157.52 ... 236.22 inch) 2E 2 x ½" NPT, IP68 1
6 001 ... 8 000 mm (236.26 ... 314.96 inch) 3E 2 x M20x1.5 (IP68, adapter) 2

4
8 001 ... 10 000 mm (315 ... 393.70 inch) 4E
Longer lengths possible to a max. of 35 000 mm Options
(114.83 ft). Contact ceg.smpi@siemens.com for No additional options A
details. With mounting eye4) B
Cable, 6 mm (0.24 inch) diameter, 316L stainless Thermal isolator
steel, non-insulated, weighted (non-conductive Without thermal isolator A
media only) Isolator, only for use when temperature range is B
Add Order code Y01 and plain text: outside of -40 ... +85 °C (-40 ... +185 °F),
"Insertion length ... mm" explosion proof approval -40 ... +70 °C
1 000 ... 2 000 mm (39.37 ... 78.74 inch)2) 0F (-40 ... +158 °F)
2 001 ... 4 000 mm (78.78 ... 157.48 inch)2)3) 1F Electronic output
4 001 ... 6 000 mm (157.52 ... 236.22 inch)2)3) 2F
2-wire loop current 4 ... 20 mA 1
6 001 ... 8 000 mm (236.26 ... 314.96 inch)2)3) 3F
(transmitter MSP 2002-2 _3300 pF)
8 001 ... 10 000 mm (315 ... 393.70 inch)2)3) 4F
Cable lengths up to 25 000 mm (984.25 inch) are 1) A minimum span of 3 pF must be maintained
possible for non-conductive media. Cable lengths 2) Available with non-conductive media only
up to 15 000 mm (590.55 inch) are possible for 3)
conductive media. Custom shipping methods required. Contact factory for more details.
Contact ceg.smpi@siemens.com for details. 4) Available in PFA insulated version only
Process connection (316L stainless steel)
Threaded connection
Selection and Ordering data Order code
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 Further designs
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K0 Please add "-Z" to Article No. and specify Order
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), L0 code(s).
JIS B 0202]
Welded flange, raised face Insertion length, specify in plain text: Y01: ... mm Y01
1½", ASME, 150 Ib B1 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
1½", ASME, 300 Ib B2 Measuring-point number/identification
1½", ASME, 600 Ib B3 (max. 27 characters) specify in plain text
2", ASME, 150 Ib C1
2", ASME, 300 Ib C2 Manufacturer's test certificate: M to DIN 55350, C11
2", ASME, 600 Ib C3 Part 18 and to ISO 9000
3", ASME, 150 Ib3) D1 Inspection Certificate Type 3.1 per EN 10204 C12
3", ASME, 300 Ib3) D2 Operating Instructions See page 4/345
3", ASME, 600 Ib3) D3
4", ASME, 150 Ib3) E1 Accessories See page 4/345
4", ASME, 300 Ib3) E2
4", ASME, 600 Ib3) E3
6", ASME, 150 Ib3) F1
6", ASME, 300 Ib3) F2
6", ASME, 600 Ib3) F3
Welded flange, Type A flat faced
DN 40, PN 16 K4
DN 40, PN 40 K5
DN 50, PN 16 L4
DN 50, PN 40 L5
DN 80, PN 16 M4
DN 80, PN 403) M5
DN 100, PN 163) N4
DN 100, PN 403) N5
DN 125, PN 163) P4
DN 125, PN 403) P5
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)

Siemens FI 01 · 2015 4/339


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC500, Threaded or Welded Flange, 7ML5515- SITRANS LC500, Threaded or Welded Flange, 7ML5515-
with Rod Sensor with Rod Sensor
Inverse frequency shift capacitance level and 77 7 77 - 77 77 Inverse frequency shift capacitance level and 7 7 7 77 - 77 7 7
interface transmitter for extreme and critical interface transmitter for extreme and critical
process conditions, such as oil and liquid gas, process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours. toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configura- Welded flange, raised face
tion in the PIA Life Cycle Portal. 1½", ASME, 150 Ib B1
Version 1½", ASME, 300 Ib B2
1½", ASME, 600 Ib B3
Rod, 16 mm (0.63 inch), PFA insulated
2", ASME, 150 Ib C1
Add Order code Y01 and Y02 and plain text: 2", ASME, 300 Ib C2
"Insertion length ... mm and active shield 2", ASME, 600 Ib C3
length ... mm"
200 ... 1 000 mm (7.87 ... 39.37 inch)1) 0A 3", ASME, 150 Ib2) D1
3", ASME, 300 Ib2) D2
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 1A 3", ASME, 600 Ib2) D3
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 2A
4", ASME, 150 Ib2) E1
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) 3A 4", ASME, 300 Ib2) E2

4
Rod, 16 mm (0.63 inch), PFA insulated with 35 mm 4", ASME, 600 Ib2) E3
(1.38 inch) stilling well in 316L stainless steel 6", ASME, 150 Ib2) F1
Add Order code Y01 and Y02 and plain text: 6", ASME, 300 Ib2) F2
"Insertion length ... mm and active shield 6", ASME, 600 Ib2) F3
length ... mm"
Welded flange, Type A flat faced
200 ... 1 000 mm (7.87 ... 39.37 inch)1)3) 0B
DN 40, PN 16 K4
1 001 ... 2 000 mm (39.41 ... 78.74 inch)3) 1B DN 40, PN 40 K5
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3) 2B
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)3) 3B DN 50, PN 16 L4
DN 50, PN 40 L5
Rod, 24 mm (0.94 inch), PFA insulated
Add Order code Y01 and Y02 and plain text: DN 80, PN 16 M4
DN 80, PN 402) M5
"Insertion length ... mm and active shield
length ... mm" DN 100, PN 162) N4
200 ... 1 000 mm (7.87 ... 39.37 inch)4) 0C DN 100, PN 402) N5
1 001 ... 2 000 mm (39.41 ... 78.74 inch)4) 1C DN 125, PN 162) P4
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)4) 2C DN 125, PN 402) P5
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)4) 3C (Note: Flange bolting patterns and facings
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)4) 4C dimensionally correspond to the applicable
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)4) 5C ASME B16.5, or EN 1092-1 standard.)
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm Approvals
(1.89 inch) stilling well in 316L stainless steel General Purpose: CE, CSA, FM, RCM 1
Add Order code Y01 and Y02 and plain text: CSA / FM Class I, Div. 2, Groups A, B, C, D 2
"Insertion length ... mm and active shield CSA / FM Class II, III, Div. 1, Groups E, F, G T4
length ... mm" ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
200 ... 1 000 mm (7.87 ... 39.37 inch)5) 0D ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C 4
1 001 ... 2 000 mm (39.41 ... 78.74 inch)5) 1D FM Class I, Div.1, Groups A, B, C, D, T4 6
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)5) 2D Enclosure/Cable inlet
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)5) 3D Aluminum epoxy coated
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)5) 4D 2 x ½" NPT, IP68 1
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)5) 5D 2 x M20 x1.5 (IP68, adapter) 2
Process connection (316L stainless steel) Options
Threaded connection No additional options A
¾" NPT [(Taper), ANSI/ASME B1.20.1] A0 Slotted holes instead of standard vent holes in B
1" NPT [(Taper), ANSI/ASME B1.20.1] B0 stilling well (refer to Operating Instructions for
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0 dimensions.)6)
2" NPT [(Taper), ANSI/ASME B1.20.1] D0 Thermal isolator/remote version
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E0 Without thermal isolator or remote electronics A
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 Thermal isolator, only for use when temperature B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] J0 range is outside of -40 ... +85 °C (-40 ... +185 °F),
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] K0 explosion proof approval -40 ... +70 °C
1¼" NPT [(Taper), ANSI/ASME B1.20.1] N0 (-40 ... +158 °F)
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] P0 Remote electronics with mounting bracket and
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R0 cable7)
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), S0 • Length: 2 m (79 inch) C
JIS B 0202]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] T0 • Length: 3 m (118 inch) D
• Length: 4 m (158 inch) E
• Length: 5 m (197 inch) F

4/340 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LC500, Threaded or Welded Flange, 7ML5515- Further designs
with Rod Sensor
Inverse frequency shift capacitance level and 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order
interface transmitter for extreme and critical code(s).
process conditions, such as oil and liquid gas, Insertion length, specify in plain text: Y01: ... mm Y01
toxic and aggressive chemicals and vapours.
Electronic output Active shield length, specify in plain text Y02
2-wire loop current 4 ... 20 mA 1 [min. length is 50 mm (2 inch)]: Y02: ... mm
(transmitter MSP 2002-2 _3300 pF) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
1)
A minimum span of 3 pF must be maintained Measuring-point number/identification
2)
(max. 27 characters) specify in plain text
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½" or larger
Manufacturer's test certificate: M to DIN 55350, C11
4)
Part 18 and to ISO 9000
Available with process connection 1" or larger
5) Inspection Certificate Type 3.1 per EN 10204 C12
Available with process connection 2 " or larger
6)
Available with version 0B … 3B, 0D … 5D and 0F only Manufacturing Test Report (Electrode Test) C18
7)
Available with approval option 1 only Operating Instructions See page 4/345
Accessories See page 4/345
4

Siemens FI 01 · 2015 4/341


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC500, Single Piece Flanged with 7ML5517- SITRANS LC500, Single Piece Flanged with 7ML5517-
Rod Sensor 77 7 77 - 7777 Rod Sensor 777 77 - 7777
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
interface transmitter for extreme and critical interface transmitter for extreme and critical
process conditions, such as oil and liquid gas, process conditions, such as oil and liquid gas,
toxic and aggressive chemicals and vapours. toxic and aggressive chemicals and vapours.
Click on the Article No. for the online configura- Single piece flange, Type B1 raised face
tion in the PIA Life Cycle Portal. DN 40, PN 16 K4
Version DN 40, PN 40 K5
Rod, 16 mm (0.63 inch), PFA insulated DN 50, PN 16 L4
Add Order code Y01 and Y02 and plain text: DN 50, PN 40 L5
"Insertion length ... mm and active shield DN 80, PN 16 M4
length ... mm" DN 80, PN 402) M5
250 ... 1 000 mm (9.84 ... 39.37 inch)1) 0A
DN 100, PN 162) N4
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 1A
DN 100, PN 402) N5
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 2A
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) 3A DN 125, PN 162) P4
DN 125, PN 402) P5
4 Rod, 16 mm (0.63 inch), PFA insulated with 35 mm
(1.34 inch) stilling well in 316L stainless steel
Add Order code Y01 and Y02 and plain text:
Single piece flange with PTFE flange facing
(applicable with versions 0A ... 3A and 0C ... 5C)4)
"Insertion length ... mm and active shield 1½" ASME, 150 Ib B4
length ... mm" 1½", ASME, 300 Ib B5
250 ... 1 000 mm (9.84 ... 39.37 inch) 0B 1½", ASME, 600 Ib B6
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 1B 2", ASME, 150 Ib C4
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 2B 2", ASME, 300 Ib C5
3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) 3B 2", ASME, 600 Ib C6
Rod, 24 mm (0.94 inch), PFA insulated 3", ASME, 150 Ib2) D4
Add Order code Y01 and Y02 and plain text: 3", ASME, 300 Ib2) D5
"Insertion length ... mm and active shield 3", ASME, 600 Ib2) D6
length ... mm" 4", ASME, 150 Ib2) E4
250 ... 1 000 mm (9.84 ... 39.37 inch) 0C 4", ASME, 300 Ib2) E5
1 001 ... 2 000 mm (39.41 ... 78.74 inch) 1C 4", ASME, 600 Ib2) E6
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 2C 6", ASME, 150 Ib2) F4
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2) 3C 6", ASME, 300 Ib2) F5
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2) 4C 6", ASME, 600 Ib2) F6
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2) 5C
Single piece flange with PTFE flange facing
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm (applicable with versions 0A ... 3A, 0C ... 5C)4)
(1.89 inch) stilling well in 316L stainless steel
DN 40, PN 16 K6
Add Order code Y01 and Y02 and plain text:
DN 40, PN 40 K7
"Insertion length ... mm and active shield
length ... mm" DN 50, PN 16 L6
250 ... 1 000 mm (9.84 ... 39.37 inch) 0D DN 50, PN 40 L7
1 001 ... 2 000 mm (39.41 ... 78.74 inch)2)3) 1D DN 80, PN 16 M6
2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3) 2D DN 80, PN 402) M7
3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)3) 3D DN 100, PN 162) N6
4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)3) 4D DN 100, PN 402) N7
5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)3) 5D
DN 125, PN 162) P6
Process connection (316L stainless steel) DN 125, PN 402) P7
Single piece flange, raised face (Note: Flange bolting patterns and facings
1½", ASME, 150 Ib B1 dimensionally correspond to the applicable
1½", ASME, 300 Ib B2 ASME B16.5, or EN 1092-1 standard.)
1½", ASME, 600 Ib B3
2", ASME, 150 Ib C1
2", ASME, 300 Ib C2
2", ASME, 600 Ib C3
3", ASME, 150 Ib2) D1
3", ASME, 300 Ib2) D2
3", ASME, 600 Ib2) D3
4", ASME, 150 Ib2) E1
4", ASME, 300 Ib2) E2
4", ASME, 600 Ib2) E3
6", ASME, 150 Ib2) F1
6", ASME, 300 Ib2) F2
6", ASME, 600 Ib2) F3

4/342 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Order code
SITRANS LC500, Single Piece Flanged with 7ML5517- Further designs
Rod Sensor 77 7 77 - 7777
Inverse frequency shift capacitance level and Please add "-Z" to Article No. and specify Order
interface transmitter for extreme and critical code(s).
process conditions, such as oil and liquid gas, Insertion length, specify in plain text: Y01: ... mm Y01
toxic and aggressive chemicals and vapours.
Active shield length, specify in plain text Y02
Approvals [min. length is 50 mm (2 inch)]: Y02: ... mm
General Purpose: CE, CSA, FM, RCM 1
CSA / FM Class I, Div. 2, Groups A, B, C, D 2 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15
CSA / FM Class II, III, Div. 1, Groups E, F, G T4 Measuring-point number/identification
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C (max. 27 characters) specify in plain text
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C 4 Manufacturer's test certificate: M to DIN 55350, C11
FM Class I, Div.1, Groups A, B, C, D, T4 6 Part 18 and to ISO 9000
Enclosure/Cable inlet Inspection Certificate Type 3.1 per EN 10204 C12
Aluminum epoxy coated
2 x ½" NPT, IP68 1 Manufacturing Test Report (Electrode Test) C18
2 x M20 x1.5 (IP68, adapter) 2 Operating Instructions See page 4/345
Options
None
Slotted holes instead of standard vent holes in
A
B
Accessories See page 4/345
4
stilling well (Refer to manual for dimensions)5)
Thermal isolator/remote version
Without thermal isolator A
Isolator, only for use when temperature range is B
outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Remote electronics with mounting bracket and
cable6)
• Length: 2 m (79 inch) C
• Length: 3 m (118 inch) D
• Length: 4 m (158 inch) E
• Length: 5 m (197 inch) F
Electronic output
2-wire loop current 4 ... 20 mA 1
(transmitter MSP 2002-2 _3300 pF)
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 2" or larger, and only available with
process connection options C1 ... F3, L4 ... P5
4)
Not available with versions 0E and 0F
5)
Available with version 0B ... 3B, 0D ... 5D and 0F only
6)
Available with approval option 1 only

Siemens FI 01 · 2015 4/343


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Article No. Selection and Ordering data Article No.
SITRANS LC500, Extended Cable version with 7ML5523- SITRANS LC500, Extended Cable version with 7ML5523-
Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7 Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7
flange1) flange1)
Inverse frequency shift capacitance level and Inverse frequency shift capacitance level and
interface transmitter for short range continuous interface transmitter for short range continuous
measurement in large storage vessels. measurement in large storage vessels.
Click on the Article No. for the online configura- Enclosure/Cable inlet
tion in the PIA Life Cycle Portal. Aluminum epoxy coated
Version2) 2 x ½" NPT, IP68 1
Rod, 16 mm (0.63 inch), PFA insulated and 316L 2 x M20x1.5 (IP68, adapter) 2
stainless steel flexible extension tube Options
Total insertion length: No additional options A
Add Order code Y01 and plain text: "Total insertion With mounting eye B
length ... mm and Y02 and plain text: Thermal isolator
Active shield length ... mm"3)4) Without thermal isolator A
• 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1) 0A Isolator, only for use when temperature range is B
• 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1) 1A outside of -40 ... +85 °C (-40 ... +185 °F),
• 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1) 2A explosion proof approval -40 ... +70 °C
4 • 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1)
• 25 001 ... 30 000 mm (984.29 ... 1181.10 inch)1)
3A
4A
(-40 ... +158 °F)
Electronic output
• 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1) 5A 2-wire loop current 4 ... 20 mA 1
Rod, 24 mm (0.94 inch), PFA insulated and 316L (transmitter MSP 2002-2 _3300 pF)
stainless steel flexible extension tube 1)
Custom shipping methods required. Contact factory for more details.
Total insertion length: 2)
Add Order code Y01 and plain text: "Total insertion A minimum span of 3 pF must be maintained.
3)
length ... mm and Y02 and plain text: See dimension drawings on page 4/354 for further explanation of Y01.
Active shield length ... mm"3)4) 4)
Inactive length is equal to the flexible extension plus transition.
• 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1) 0B See dimension drawings on page 4/354 for further explanation of Y02.
• 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1) 1B
• 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1) 2B
• 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1) 3B
• 25 001 ... 30 000 mm (984.29 ... 1 181.10 inch)1) 4B
• 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1) 5B
Process connection (316L stainless steel)
Threaded connection
2" NPT [(Taper), ANSI/ASME B1.20.1] A0
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B0
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202] D0
Welded flange, raised face
2", ASME, 150 Ib C1
2", ASME, 300 Ib C2
3", ASME, 150 Ib1) D1
3", ASME, 300 Ib1) D2
4", ASME, 150 Ib1) E1
4", ASME, 300 Ib1) E2
6", ASME, 150 Ib1) F1
6", ASME, 300 Ib1) F2
Welded flange, Type A flat faced
DN 50, PN 16 L4
DN 50, PN 40 L5
DN 80, PN 16 M4
DN 80, PN 401) M5
DN 100, PN 161) N4
DN 100, PN 401) N5
DN 125, PN 161) P4
DN 125, PN 401) P5
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1 standard.)
Approvals
General Purpose: CE, CSA, FM, RCM 1
CSA / FM Class I, Div. 2, Groups A, B, C, D 2
CSA / FM Class II, III, Div. 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C 4
FM Class I, Div. 1, Groups A, B, C, D T4 6

4/344 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500
Selection and Ordering data Order code Selection and Ordering data Order code
Further designs Accessories
Please add "-Z" to Article No. and specify Order General Purpose
code(s).
1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA
Insertion length, specify in plain text: Y01: to mm Y01 NEMA6, -40 ... -100 °C (-40 ... -212 °F),
(Includes measuring range plus cable extension) - cable size 6 ... 12 mm (0.236 ... 0.472 inch)
see dimensional information on page 4/354
M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC
Active shield/cable extension length, specify in Y02 NEMA6, -40 ... -100 °C (-40 ... -212 °F),
plain text [min. length is 50 mm (2 inch)]: cable size 7 ... 12 mm (0.275 ... 0.472 inch)
Y02: to mm (see dimensional information on
page 4/354) Hazardous Locations

Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB
Measuring-point number/identification Flameproof Exd, and Increased Safety ATEX II 2 GD
(max. 27 characters) specify in plain text ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
Manufacturer's test certificate M to DIN 55350, C11 IP68, NEMA4X, cable sizes 5.5 ... 12 mm
Part 18 and to ISO 9000 (0.216 ... 0.472 inch)

4
Inspection Certificate Type 3.1 per EN 10204 C12 M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD
Flameproof Exd, and Increased Safety ATEX II 2 GD
Operating Instructions Article No. ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in
English 7ML1998-5GE04 Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67,
IP68, NEMA4X, cable sizes 5.5 ... 12 mm
French 7ML1998-5GE12 (0.216 ... 0.472 inch)
Spanish 7ML1998-5GE21 Transmitter, MSP 2002-1, 330 PF1) 7ML1830-1JP
German 7ML1998-5GE33 Transmitter, MSP 2002-2, 3 300 PF1) 7ML1830-1JQ
Note: The Operating Instructions should be Transmitter, MSP 2002-3, 6 600 PF (used with 7ML1830-1JR
ordered as a separate line item on the order. conductive fluids and probe lengths >10 000 mm)1)
This device is shipped with the Siemens Milltronics SITRANS RD100, loop powered display - 7ML5741-...
manual DVD containing the ATEX Quick Start and see Chapter 7
Operating Instructions library.
SITRANS RD200, universal input display with 7ML5740-...
Modbus conversion - see Chapter 7
SITRANS RD300, dual line display with totalizer 7ML5744-...
and linearization curve and Modbus conversion -
see Chapter 7
SITRANS RD500 web, universal remote monitoring 7ML5750-...
solution for instrumentation - see Chapter 7
For applicable back up point level switch -
see point level measurement section
1)
Transmitters not suitable for Intrinsically Safe application
(ATEX II 1G EEx ia IIC T4 or CSA/FM Class 1 Div. 1 Groups A, B, C and D

Please contact ceg.smpi@siemens.com for special requests.

Siemens FI 01 · 2015 4/345


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

■ Characteristic curves
Pressure/temperature curve
LC500 cable probes
threaded process connections
(7ML5513)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
4 -40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
500 ºF
(260 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
permitted operating pressure = 10 bar (145 psi) at 75 °C

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

4/346 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 PFA rod probes
Threaded process connections
(7ML5515)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

120 bar (1.740 psi) 4


110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

Atmospheric 10 bar (145 psi)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515)

Siemens FI 01 · 2015 4/347


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 cable probes
ASME flanged process connections
(7ML5513)

Permitted operating pressures P

20 bar (290 psi)

10 bar (145 psi)


Atmospheric ASME 150 lb1)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)

4 -29 ºC
(-20 ºF)
Permitted operating temperature T

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

4/348 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 PFA rod probes
ASME flanged process connections
(7ML5515 and 7ML5517)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

120 bar (1.740 psi) 4


110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

ASME 600 lb1)


50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC)(-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)
1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

Siemens FI 01 · 2015 4/349


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 cable probes
EN flanged process connections
(7ML5513)

Permitted operating pressures P

20 bar (290 psi)

10 bar (145 psi)


Atmospheric PN 161)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)

4 -29 ºC
(-20 ºF)
Permitted operating temperature T

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

4/350 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 PFA rod probes
EN flanged process connections
(7ML5515 and 7ML5517)

Permitted operating pressures P

150 bar (2.175 psi)

140 bar (2.030 psi)

130 bar (1.885 psi)

120 bar (1.740 psi) 4


110 bar (1.595 psi)

100 bar (1.450 psi)

90 bar (1.305 psi)

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

Atmospheric 10 bar (145 psi) PN 161)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC)(-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

Siemens FI 01 · 2015 4/351


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 single piece flanged rod probes with PTFE facing
EN flanged process connections
(7ML5517)

Permitted operating pressures P

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

4 50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

10 bar (145 psi) PN 161)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)

4/352 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Pressure/temperature curve
LC500 single piece flanged rod probes with PTFE facing
ASME flanged process connections
(7ML5517)

Permitted operating pressures P

80 bar (1.160 psi)

70 bar (1.015 psi)

60 bar (870 psi)

ASME 600 lb1)


50 bar (725 psi)
4
40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)

Siemens FI 01 · 2015 4/353


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

■ Dimensional drawings
Cable version, non-insulated Cable version, insulated
welded flange (7ML5513) welded flange (7ML5513)

Transmitter/
electronics
Option for mounting eye
20 (0.79) only available for PFA
insulated cable
min. = 1 000 (39.40) / max. = 35 000 (1 378)

min. = 1 000 (39.40) / max. = 35 000 (1 378)


Ø9 (0.35)

Measuring
length
Stainless PFA insulated

4
Y01 (insertion length)

Y01 (insertion length)


steel cable probe

350 (13.78)
Masuring length

Ø9 (0.35) Ø34.5 (1.36)


Ø6 (0.24)

Mounting

350 (13.78)
250 (9.84)

eye
Stainless Stainless Ø12

20 (0.79)
steel weight steel weight (0.47)
Ø25 (0.98)

Ø32 (1.26) Ø34.5 (1.36)

Extended cable version with rod sensor Extended cable version with rod sensor
welded flange (7ML5523) welded flange (7ML5523)

Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
20 (0.79) part of measuring length.
3) For Y02 lengths greater than 5 000 (197),
cable is inactive and is not actively
shielded.
min. = 5 000 (197) / max. = 35 000 (1 378)

min. = 5 000 (197) / max. = 35 000 (1 378)


Y02 Inactive length

Y02 Inactive length

4) Minimum length = 200 (7.87), maximum


Stainless length = 5 500 (216.54)
Stainless
steel
steel 5) Insertion length Y01 =
flexible
54 (2.12)

flexible Y02 + measuring length + 92 (3.62)


tube
Y01 (insertion length)

Y01 (insertion length)


(3.62) (2.48)

tube 6) Insertion length Y01 =


63

Y02 + measuring length + 15 (0.59)


Mounting
Ø40
92

eye option
(1.57) Mounting
eye option
Measuring
length

Inactive tip
100 (3.9)
Measuring

Mounting
length
(0.79)

eye
20

Ø16
(0.63) Ø24
(3.62)

Ø12 (0.47) (0.94)


92

Ø25 (0.98) Ø35


Ø48 (1.88) (1.37) 15 (0.60)

SITRANS LC500 - Cable Versions, dimensions in mm (inch)

4/354 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Cable version, non-insulated 1) Cable version, insulated 2)


Welded flange (7ML5513) Welded flange (7ML5513)

Transmitter/
electronics
Option for mounting eye
only available for PFA
insulated cable

Ø9 (0.35)

Measuring
length
Stainless PFA insulated
max. = 35 000 (1 378)

max. = 35 000 (1 378)


Y01 (insertion length)

Y01 (insertion length)


steel cable probe
Measuring length

350 (13.78)
Ø6 (0.24) Ø9 (0.35) Ø34.5 (1.36)
4
Mounting

350 (13.78)
250 (9.84)

Stainless steel Stainless steel eye


weight, actual weight, actual Ø12

20 (0.79)
weight = (1.27 kg weight = (2.15 kg (0.47)
[2.80 lb]) [4.75 lb]) Ø25 (0.98)

Ø32 (1.26) Ø34.5 (1.36)

Extended cable version with rod sensor 3) Extended cable version with rod sensor 3)
Welded flange (7ML5523) Welded flange (7ML5523)

Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
part of measuring length.
3) For Y02 lengths greater than 5 000 (197),
cable is inactive and is not actively
shielded.
min. = 5 000 (197) / max. = 35 000 (1 378)

min. = 5 000 (197) / max. = 35 000 (1 378)


Y02 Inactive length

Y02 Inactive length

4) Minimum length = 200 (7.87), maximum


Stainless length = 5 500 (216.54)
Stainless
steel
steel 5) Insertion length Y01 =
flexible
54 (2.12)

flexible Y02 + measuring length + 92 (3.62)


5)

6)

tube
Y01 (insertion length)

Y01 (insertion length)


(3.62) (2.48)

tube 6) Insertion length Y01 =


63

Y02 + measuring length + 15 (0.59)


Mounting
Ø40
92

eye option
(1.57)
Mounting
eye option
Measuring
length 4)

Inactive tip
100 (3.9)
Measuring
length 4)

Mounting
(0.79)

eye
20

Ø16
(0.63) Ø24
(3.62)

Ø12 (0.47) (0.94)


92

Ø25 (0.98) Ø35


Ø48 (1.88) (1.37) 15 (0.60)

SITRANS LC500 - Cable Versions, dimensions in mm (inch)

Siemens FI 01 · 2015 4/355


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Rod version Rod version with stilling well Remote electronics with mounting bracket option
threaded (7ML5515) threaded (7ML5515) threaded (7ML5515)

Transmitter/

150 (6)
electronics

205 (8.1)

205 (8.1)
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)

min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)


min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)

min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)


Stainless steel flexible tube
Y02 1)

Y02 1)
20
(0.79)

Stainless
steel stilling
well
General purpose approval only.
Y01 (insertion length)

Y01 (insertion length)


Vent holes or
optional slots
1)

Measuring length1)
4
Measuring length

Standard configuration
PFA insulated
(all versions)
probe

PFA insulated

205 (8.1)
probe
Ø16 (0.63)
M20: 160 (6.3)
or Ø24 (0.94)
1/2" NPT: 230 (9.1)
*

Ø16 (0.63) Ø35 (1.38) With thermal isolator


or Ø24 (0.94) or Ø48 (1.89) option (all versions)

* = 30 (1.18) inactive tip


With explosion-proof
seal option
(all versions)
Note:
1) Minimum Y02 (active shield length) = 50 (1.96),

430 (16.9)
minimum measuring length = 200 (7.87) 270 (10.6)

Thermal
isolator

SITRANS LC500 - Rod Versions, dimensions in mm (inch)

4/356 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

Rod version Rod version with stilling well Remote electronics with mounting bracket option
Welded flange (7ML5515) Welded flange (7ML5515) Welded flange (7ML5515)
Single piece flange (7ML5517) Single piece flange (7ML5517) Single piece flange (7ML5517)

150 (6)
Transmitter/
electronics

205 (8.1)
(Typical) Stainless steel flexible tube
min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)

min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94)


min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)

min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63)


Y02 1)

Y02 1)
General purpose approval only.
Stainless steel
stilling well
2)

2)
PTFE flange facing option
Y01 (insertion length)

Y01 (insertion length)


4
Vent holes or
single piece flange only (7ML5517)
optional slots
Measuring length1)

Measuring length1)
PFA insulated
probe

PFA insulated
probe

Ø16 (0.63)
or Ø24 (0.94) Raised PTFE flange
face flange facing
*

Ø16 (0.63) Ø35 (1.38) No stilling well or enamel probe available with this
or Ø24 (0.94) or Ø48 (1.89) option.

* = 30 (1.18) inactive tip

Standard configuration Flange facing (raised face)


(all versions) Flange class Facing thickness
ASME 150/300 2 (0.08)
ASME 600/900 7 (0.28)
205 (8.1)

PN16/25/40/64 2 (0.08)
M20: 160 (6.3) PTFE facing (additional) 2 (0.08)
1/2" NPT: 230 (9.1)

With thermal isolator


option (all versions)
Notes:
With explosion-proof 1) Minimum Y02 (active shield length) = 50 (1.96),
seal option (all minimum measuring length = 200 (7.87)
versions) 2) Insertion length does not include any raised face/gasket face
dimension (see Flange Facing table above).
430 (16.9)
270 (10.6)

Thermal
isolator

SITRANS LC500 - Rod Versions, dimensions in mm (inch)

Siemens FI 01 · 2015 4/357


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC500

■ Schematics

Ground lug

Protective
label
Solid state
switch relay
(any polarity)
Instrument
system
ground 4 ... 20 mA
current loop
connection
Measuring Type:
Ser.: (any polarity)
signal Date:
Rev.:
(mini- Tampering voids warranty

coaxial

4
cable)

Ground connection
point for instrument
system

SITRANS LC500 connections

4/358 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Continuous level measurement – Capacitance transmitters
SITRANS LC300 and LC500 Specials

■ Selection and ordering data


LC300 and LC500 Specials1) LC300 and LC500 Specials1)
Article No. Article No.
LC300 Cable Extensions, LC300 Mounting Eye
316L stainless steel

Spare mounting eye (LC300 PFA versions only) A5E01163717


LC300 Weight Kit, 316L stainless steel

Kit, stainless steel cable extension, 1 m, A5E01163688


adjustable by customer
Kit, stainless steel cable extension, 3 m, A5E01163689
adjustable by customer
Kit, stainless steel cable extension, 5 m, A5E01163690
adjustable by customer
Kit, stainless steel cable extension, 10 m, A5E01163691
Kit, Spare stainless steel weight. To be used in A5E01163727 4
any cable version of CLS300, or stainless steel
adjustable by customer cable version of LC300
Kit, stainless steel cable extension, 15 m, A5E01163693 LC500 Gasket (IP65), Silicone
adjustable by customer
Kit, stainless steel cable extension, 20 m, A5E01163695
adjustable by customer
LC300 Cable Extensions,
316 stainless steel with PFA coating
Spare gasket, LC500 enclosure version, IP65 A5E01163728
LC500 Blind Lid

Kit, PFA cable extension, 1 m A5E01163709 Spare LC500 aluminum blind lid A5E01163729

Kit, PFA cable extension, 3 m A5E01163710 LC500 Mounting Eye

Kit, PFA cable extension, 5 m A5E01163711


Kit, PFA cable extension, 10 m A5E01163712
Kit, PFA cable extension, 15 m A5E01163713
Spare mounting eye (PFA cable version only) A5E01163717
Kit, PFA cable extension, 20 m A5E01163714
LC500 Mounting Bracket

Spare mounting bracket A5E01163730


LC500 Sanitary Versions2)

1) Special flange sizes and facings are available. Please contact


ceg.smpi@siemens.com for part number and pricing.
Submit Application Questionnaire found on page 4/11.
2) Please contact ceg.smpi@siemens.com for part number and pricing.
Submit Application Questionnaire found on page 4/11.

Please contact ceg.smpi@siemens.com for special requests.

Siemens FI 01 · 2015 4/359


© Siemens AG 2014

Level Measurement
Communication
SmartLinx module

■ Overview ■ Technical specifications


Module type PROFIBUS DP
• Interface RS 485 (PROFIBUS standard)
• Transmission rate All valid PROFIBUS DP rates from
9 600 Kbps to 12 Mbps
• Rack address 0 ... 99
• Connection Slave
• SmartLinx module compatibility • MultiRanger 100/200
• HydroRanger 200

Module type DeviceNet


• Interface DeviceNet physical layer
• Transmission rate in kbps 125, 250, 500

4 • Rack address
• Connection
0 ... 63
Slave (group 2)
• SmartLinx module compatibility • MultiRanger 100/200
SmartLinx modules provide direct digital connection to popular • HydroRanger 200
industrial communications buses with true plug-and-play
compatibility with products manufactured by Siemens.
Selection and Ordering data Article No.
■ Benefits SmartLinx module for MultiRanger 100/200 and
HydroRanger 200
• Fast, easy installation
PROFIBUS DP module 7ML1830-1HR
• Direct connection: no additional installation required
DeviceNet module 7ML1830-1HT
• Scaleable application layer allows for optimized network
bandwidth and memory requirements Operating Instructions
• Modules available for PROFIBUS DP and DeviceNet PROFIBUS communications module
• English 7ML1998-1AQ03
■ Application • French 7ML1998-1AQ13
Many Siemens products include HART, PROFIBUS PA and • German 7ML1998-1AQ33
Modbus communications. For additional communication DeviceNet 7ML1998-1BH02
modules, SmartLinx cards are the answer. This device is shipped with the Siemens Milltronics
manual DVD containing Quick Starts and Operat-
They’re fast and easy to install, and can be added at any time. ing Instructions.
The module simply plugs into the socket on any SmartLinx-
enabled product. They require no secondary private buses or • English 7ML1998-1BH02
gateways and no separate wiring. There are no extra boxes to • French 7ML1998-1BH12
connect to your network so there’s a minimum load on
engineering and maintenance staff. Spare SmartLinx software
PROFIBUS DP data diskette 7ML1830-1CL
SmartLinx provides all data from the instrument, including
measurement and status, and allows changes to operation DeviceNet data diskette 7ML1830-1CM
parameters to be done over the bus or telemetry link. The user
can select which data in the application layer to transfer over the
bus. This selection saves bandwidth and memory and optimizes
data throughput and speeds up the network, enabling you to
connect more instruments to your network.

4/360 Siemens FI 01 · 2015


© Siemens AG 2014

Level Measurement
Communication
Dolphin Plus Software
Compatibility
■ Overview
Dolphin Plus is compatible with Microsoft Windows
95/98/NT4/Me/2000/XP and works with a wide range of Siemens
products, including:
• SITRANS LU10
• SITRANS LU02
• SITRANS LU01
Connection to a Siemens instrument may be a direct RS 232
serial connection or via an RS 485 converter or Siemens infrared
ComVerter, depending on the instrument being configured.
Meets VDE 2187 user interface requirements.
(Most other Siemens level devices use Simatic PDM
configuration software.)

Selection and Ordering data


Dolphin Plus
Article No.
7ML1841- 4
Instrument configuration software to quickly and 7AA 0 7
Dolphin Plus is instrument configuration software that allows you easily configure, monitor, tune and diagnose most
to quickly and easily configure, monitor, tune and diagnose Siemens devices remotely, from your desktop PC or
several Siemens level devices remotely (see list below). connected directly in the field using a laptop.
Remote access is available using your desktop PC or connected Dolphin Plus Software includes a software DVD,
directly in the field using a laptop. and a nine pin adapter with a 2.1 m (82.7 inch)
cable for connection to a PC serial port.

■ Benefits Click on the Article No. for the online configura-


tion in the PIA Life Cycle Portal.
• Real-time monitoring and adjustment of parameters
RS 485 to RS 232 converter
• On-screen visualization of process values No 0
• Saving and visualization of echo profiles for a wide range of Yes 1
Siemens level meters ComVerter
• Copying of data for programming several devices No 0
• Quick setup and commissioning of device Yes 1
• Generation of configuration reports within seconds
Selection and Ordering data Article No.
Note: Operating Instructions
The Dolphin Plus software is only available in English. Connection manual, English:
Included on Dolphin Plus DVD and available at
■ Application www.siemens.com/processautomation
Spare parts
Dolphin Plus is easy to install and use. Just load the software
from the DVD. In minutes, you’re ready to set up or modify Converter, RS 485 to RS 232 (D-Sub) 7ML1830-1HA
complete parameter configurations for one or more devices. Kit containing one 9-pin D-Sub to RJ11 Adapter 7ML1830-1MC
and one 2.1 meter telephone cable with two male
Following configuration, you can alter parameters, upload and jacks
download parameter sets to and from disk, and use parameter
sets saved from other instruments. Reading of echo profiles ComVerter, Infrared link 7ML1830-1MM
permits fine tuning without the need for special instruments.
Built-in quick start wizards and help functions guide you through
the entire process.

Siemens FI 01 · 2015 4/361


© Siemens AG 2014

Level Measurement

Notes

4/362 Siemens FI 01 · 2015

You might also like