Jenis shutdown
A. Shutdown normal
B. Shutdown insiden: Shutdown insiden biasa dan shutdown insiden emergency
1. Contact with electrical team to immediately start black start generator, then
immediately press the Emergency Trip or press the shutdown button.
2. Check the MSV, valve control, the extraction check valve, primary extraction and a
secondary extraction manual valve manual valve should be closed.
3. Check the speed of the turbine should go down (usually eg normal protection, MSV is
closed and automatic generator trip switches)
4. Quick start DC oil pump (when one turbine running), all equipment that running is
converted into a shutdown condition.
5. After the auxiliary power restored, immediately close the valve outlet each piece of
equipment running, start HP oil pump, CWP, BFP.
6. Open motorize valve dan manual valve vaccum breaker, atur level hot well.
7. Saat speed naik sampai 200r/min start jacking oil pump.
8. After the rotor gear turning static start and stop running and gland sealing heater
fan.
Shutdown InsidenBiasa
Syaratshutdown insidenbiasa :
It shall not break the vacuum utntuk shutdown if turbine ordinary incident to the
following conditions:
1. Pressure steam inlet is greater than 6.4MPa ato steam inlet temp is greater than
470 ℃ and could not get back to normal.
2. Pressure steam inlet is smaller than ato 2.05MPa steam inlet temp is smaller than at
360 ℃ and could not get back to normal.
3. Vacuum condenser lower than in -0.061MPa
4. Rod dislodged or broken governor, governor or bulkhead rotary valve stuck.
5. Vibarsi bearing greater than 0.06mm and bigger.
6. Pressure steam inlet is lower than 2.6MPa, but higher than 1.76 MPa and in a short
time can not back to normal.
7. The temperature of the steam inlet is lower than 370 ℃ , but was higher than
360 ℃ , and in a short time or can not return to normal.
8. Vacuum lower than - 0.073 MPa , but higher than in - 0.061MPa and in a short time
can not back to normal .