You are on page 1of 63

Inhemeter Distribution Automation (InheGrid)

State of Art and Technology Proven Solution


Self-Healing Distribution
Management Solution (DMS)
Distribution networks are growing very fast and covering large scale in urban and rural area,
pinpointing of fault in distribution network, providing isolation of faulty area to minimize
the number of users that are impacted by the disturbance, clearing fault and restoration of
network in minimum duration needs advance technology. Self-Healing Distribution
Management Solution is complete solution implemented on Distribution power network,
includes medium/high voltage feeder, distribution substation and high voltage substation,
the solution provides real time monitoring and intelligent control (monitoring critical
parameters of distribution power network, locates and reports faults, automatically isolates
faulty area, restores non-faulty area, provides remote control and reconfiguration, etc.).
Self-Healing DMS Architecture
IHM-6200 FTU
Feeder Terminal Unit
IHM-6200 FTU (Feeder Terminal Unit) is designed based on advanced technology for
management of MV feeders (11kV, 15kV, 20kV, 25kV, 35kV) to help utility company for
detection and pinpointing of fault in distribution network, providing isolation of faulty area
to minimize the number of users that are impacted by the disturbance, clearing fault and
restoration of network in minimum duration.
• Compatible for MV feeder 11kV, 15kV, 20kV, 25kV, 35kV
• Remote data acquisition
• Current protection
• Reclosing,remote control,local control,locally button operation and switch
state acquisition
• It supports multiple communication methods to facilitate the automatic distribution
system reconfiguration
• Support 7 or 14 analogue inputs include zero sequence
• Support 8 or 18 digital inputs and 2 or 4 digital outputs
Through modern communication network (GPRS/3G/RF/FO), it realizes remote data
measurement related to the MV feeders operations and in real-time condition, as well as
data acquisition, data analysis and capturing and reporting abnormal events.
IHM-6200/6300 FTU Feeder Terminal Unit
IHM-6200/6300 is design in different shape BOX type and bell type .

IHM-6200 FTU-BOX IHM-6300 FTU-BELL


FTU with vacuum Switch C.B or L.S
IHM-6200 FTU can connect to circuit breaker, load switch and reclosing control equipment in order to realize telemetry data acquisition,
current protection, reclosing, remote control, local control, locally manual operation and switch state acquisition.

C.B L.S FTU


Bell type FTU
With load Switch
IHM-6400 DTU (Distribution Terminal Unit)
IHM-6400 DTU (Distribution Terminal Unit) is installed in the distribution feeder switching station, Ring
Main Unit (RMU), HV substation and mini-substation to acquire the analog and digital data to detect
and report the faults of distribution feeder lines. These information will remotely report to the Central
system via remote communication.

• Support many inputs analog (4 to 16 feeder lines), digital input data (up to 96 DI), digital
output data, control output (up to 18)Remote data acquisition
• Report the faults of distribution line
• Execution control command from the central system

IHM-6400 DTU can receive the control command from the central system to remotely operate the
distribution switch. In this way, IHM-6400 DTU can identify the faulty, re-configure the network,
recovery the power supply and reduce the power outage time as well as improve power supply
reliability of distribution network.
IHM-6400 DTU Distribution Terminal Unit
IHM-6400 is design in different capacity 4 Feeders lines, 6 Feeders lines, 8 Feeders lines and 12 Feeders lines .

16 Feeders Line 6 Feeders Lines 4 Feeders Lines


Vacuum Circuit Breaker

Inhemeter’s Vacuum Circuit Breaker accomplishes safe and


efficient fault interruption to prevent temporary faults,
especially in overhead lines where lightning strikes, wind-
borne debris, crossed lines, fallen branches, or small animals
and birds on the insulation can cause problems.

• Compatible for MV feeder 11 kV, 15kV, 20kV, 24kV, 35kV


• Rated current 630A or 1250A
• Protection degree IP67
• High performance
• Rated operation order Open -0.3s- close and open -180s-
close and open
• Closing time <=100ms
• Breaking <=50ms

Inhemeter’s Vacuum Circuit Breaker is suitable for outdoor


installation and with connection to FTU/DTU provides
advanced distribution management for utility company,
includes remote reconfiguration of MV/HV network, connect
and disconnect, reclosing, insolation of faulty area, …
Vacuum Circuit Breaker
Inhemeter provides Vacuum Circuit Breaker in different voltage level

IHM-6511-OVB IHM-6524-OVB IHM-6533-OVB


SF6
Load Break Switch
Inhemeter’s SF6 gas-insulated column Load Breaker Switch
with high arc extinguishing and insulation capability has
been designed based on advanced technology to accomplish
safe and efficient load interruption in overhead lines where
in urban or rural area...
• Compatible for MV feeder 11 kV, 15kV, 20kV, 35kV
• Rated current 630A
• Protection degree IP67
• High performance
• Closing time <=100ms
• Breaking <=50ms
Inhemeter’s SF6 gas-insulated column Load Breaker Switch is
suitable for outdoor installation on up to MV/HV feeders
(pole mounted) and with connection to DTU/FTU provides
advanced distribution management for utility company,
includes remote connection and disconnection of load in
MV/HV network, connect and disconnect, insolation of fault
SF6 Load Break Switch
Inhemeter provides SF6 Load Break switch in different voltage level

IHM-6512-OSLS IHM-6524-OSLS IHM-6534-OSLS


Vacuum
Load Break Switch
Inhemeter’s Vacuum column Load Breaker Switch with high arc
extinguishing and insulation capability has been designed
based on advanced technology to accomplish safe and efficient
load interruption in overhead lines where in urban or rural
area...
• Compatible for MV feeder 11 kV, 15kV, 20kV, 35kV
• Rated current 630A
• Protection degree IP67
• High performance
• Closing time <=100ms
• Breaking <=50ms
Inhemeter’s Vacuum column Load Breaker Switch is suitable
for outdoor installation on up to MV/HV feeders (pole
mounted) and with connection to DTU/FTU provides advanced
distribution management for utility company, includes remote
connection and disconnection of load in MV/HV network,
connect and disconnect, insolation of fault
Vacuum Load Break Switch
Inhemeter provides Vacuum Circuit Breaker in different voltage level

IHM-6512-OVLS IHM-6524-OVLS IHM-6534-OVLS


IHM-6100 FCI
(Fault Circuit Indicator)
Inhemeter’s IHM-6100 (Fault Circuit Indicator) has been designed based on advanced
technology for overhead cable to pinpoint fault location and accurately log load in any point
along the electric distribution power network (faults like two-phase or three-phase short-
circuit fault and single-phase earth fault). IHM-6100 utilized low power mesh RF network to
communicate with Smart Data Collector.

• Monitoring of Over Head MV feeder Status


• Supplied directly from power line
• Outage and Loss of Current Notification
• Supper capacitor for 3 days and battery (10 years)

IHM-6100 equipped with visual indication to support visual tracking and audit at field while
sending critical data, event and alarm to the Central system through RF network. IHM-6100
has been designed based on latest technology to be supplied from power line and
maintenance-free life during long life. Installation process of IHM-6100 is very simple and can
be done on hot line anywhere.
IHM-6100 Data Collector
(Data Collector for over-head FCI)

IHM-6100 Data Collector is the core element of fault locating system acting as
gateway between FCI and central system, IHM-6100 Data Collector using short-range
wireless and remote wireless hybrid network technology, makes the system with
channel monitoring, fault alarm and switching capability, support system diagnosis,
self-healing and communication interrupt recovery data after the continuous
transmission function.

Through the use of solar energy and maintenance free battery, the high reliable
power supply system ensures the system stable and reliable, utility company can
monitor the condition information and fault information of the line in real time.
IHM-6101 (Fault Circuit Indicator)+ Zero
Sequence
IHM-6101 (Fault Circuit Indicator) has been designed based on advanced technology for
underground cable to pinpoint fault location and accurately log load in any point along the
electric distribution power network (faults like two-phase or three-phase short-circuit
fault and single-phase earth fault)

• Monitoring of Underground MV feeder Status


• Battery Operated (15+ year life)
• Outage and Loss of Current Notification
• Support RF network of Fiber optic
• Seamless back-office integration – OMS/DMS, SCADA and other Software

IHM-6101 utilized low power RF/ Fiber optic network to communicate with Smart Data
Collector. IHM-6101 has been designed based on latest technology to be maintenance-free
life during long life. Installation process of IHM-6101 is very simple and can be done on hot
line anywhere..

IHM-6101 + Zero sequence


IHM-6101 Data Collector
(Data Collector for Over-Head FCI)

IHM-6101 Data Collector is the core element of fault locating system


acting as gateway between FCI and central system, IHM-6101 Data
Collector using short-range wireless and remote wireless hybrid network
technology, makes the system with channel monitoring, fault alarm and
switching capability, supports system diagnosis, self-healing and
communication interrupt recovery data after the continuous transmission
function. Utility company can monitor the condition information and
fault information of the line in real time.
IHM-6000 (TTU) Smart
Transformer Terminal Unit

IHM-6000 monitors transformer running state in real time (metering and monitoring the
transformer output power), meanwhile acting as Data Concentrator for gathering of
metering data from Smart Meters in subsidiary of transformer. It provides the data
necessary to conduct preventive maintenance and proper network planning, ultimately
improving the stability of the power supply.
• Increase Low Voltage power network visibility
• Power quality measurement like Harmonic, THD, power factor, unbalance in
current and voltage
• Abnormal events alerts for transformer and LV network
• High accuracy under all operational conditions: Class 0.5S
• Flexible input and output
• Open standardized protocol for metering and SCADA: DLMS/COSEM, RTU
MODBUS, DNP3.0, IEC 870-5-102 , GB 376.1, DL/T645
• Up to 32 odd harmonic and THD measurement
• Support OFDM, modulation for PLC communication to Smart meter, like PRIME, G3
or Support fixed or Mesh RF for communication to Smart meter
• Support GSM/GPRS/3G, DSL, Fiber Optic for communication to central system
• Supports up to 1200 Smart meters
• Street Light feeder monitoring and Controlling
IHM-6000 (All in one)

Transformer
temperature
Self-Healing DMS Communication Infrastructure

Center1 Center 2

Firewall
Web based connection Private Communication

UHF Antenna

FCI
FTU+ Circuit break Switch

DTU/RTU TTU
Center 3 Center n
Self-Healing DMS
Communication Advantage
• Security, UHF/VHF modem that using licensed frequency make sure
there is no interfere from other devices Private Communication network
• Reliability, UHF/VHF modem will provide reliable communication for
utility company and utility company can achieve goal of Control
system for reliable control UHF/VHF
• Operation cost, UHF/VHF solution doesn’t have operation cost and Antenna

with one-time investment utility company can use this media without
any other charge fee
• Private communication, UHF/VHF is private communication under UHF/VHF modem
control of utility company

TTU
FCI FTU+ Circuit break Switch
DTU/RTU
Self-Healing DMS Benefits
• Real-time monitoring, signaling and controlling of distribution power
network, which allows power network to be utilized in optimal state.
• Anticipation, which enables the system to automatically look for problems
that could trigger larger disturbances.
• Rapid isolation, which allows the system to isolate parts of the network that
experience failure from the rest of the system to avoid the spread of
disruption and enables a more rapid restoration.
• Reduce power outages and minimize their length when they do occur.
Index Normal time After implementation of DMS
Average response time on pinpoint a 2 hours less than 10 seconds
fault / outage
Average restoration of power 2-3 hours Less than 60 second
network
Average time spent on performing 2-3 hours 1 to 4 minutes
switching / isolation for planned
outages
Customer power cut due to outages 2 hours less than 20 seconds
Self-Healing DMS work Principal
Inhemeter’s self-healing solution ensures effective fault detection, isolation and cleaning in fast reaction
within the distribution network.
Self-healing DMS Benefits:
• Centralized monitoring & controlling all the substations and feeder lines
• Send the alarms & events(short circuit, earth fault, etc.) to DMS System
• Cost effective solution, fast and quick return of investment
• Reduce the outage duration and improve power supply reliability and power quality
• Implement self-healing power network, fault diagnosis and system can isolate faulty area
Self-Healing DMS Work principle

• Error happen in one feeder


• C.B in substation is disconnected
• FTUs and FCI send error signal to Smart DMS
• Smart DMS locate error place
Self-Healing DMS Work principle

• Smart DMS Isolating faulty Area


• Smart DMS start reenergize non-faulty
area from other feeder
• Smart DMS create work order to clean
fault
Example

DTU

Close
Open
C.B FTU
Example of Self-healing power network

A fault occurs in Zone 2

• The recloser completes its three operation and locks out


• Zones 1, 2, 3 and 4 are de‐energized
Isolating zone 2 and reenergizing zone 1

1. Close Substation C.B


2. Zone 1 in now reenergized

• DA system Open top switches


• Isolates Zone 2 from the circuit

CLOSE
Isolating and reenergizing zone 4

1. Isolating zone 4
2. Zone 4 in now reenergized

CLOSE
Isolating
And
CLOSE
reenergizing
zone 3
Smart Prepayment
Metering Solution
for LPU Customers
LPU (Large Power Unit) customers are very important for utility company
because they are few but their consumption is very high, management of
these customers are critical for utility companies
Benefits of Smart Prepayment Metering for LPU users:
• ROI less than one year
• Improve Cash flow
• Cancelation of theft and meter manipulation
• Reduce Distribution System Losses;
• Increase Distribution Network Manageability and reliability;
• Reduce outage numbers and durations;
• Improve billing collection rate;
• Improve the quality of supplied electricity;
LPU Customer
System Architecture
MV Metering Unit
(BOX 11kV)

• Up to 11 kV direct connection
• Prepayment and post-payment
• Wired or RF CIU
• Plug & play communication module
• Tamper proof
• Combined CT , PT, Meter
• Open standardized protocol: DLMS/COSEM
• Local and remote firmware upgrade
• Multi tariff
• High Accuracy
• Remote Connect and disconnect with External Smart Switch (optional)

BOX 11kV
MV Metering Unit
(BOX 11kV)

• Up to 15 kA direct connection
• Prepayment and post-payment
• Wired or RF CIU
• Plug & play communication module
• Tamper proof
• Combined CT , PT, Meter
• Open standardized protocol: DLMS/COSEM
• Local and remote firmware upgrade
• Multi tariff
• High Accuracy
• Remote Connect and disconnect with External Smart Switch (optional)

BOX 11kV
MV Metering Unit
(BOX 22kV)

• Up to 22 kV direct connection
• Prepayment and post-payment
• Wired or RF CIU
• Plug & play communication module
• Tamper proof
• Combined CT , PT, Meter
• Open standardized protocol: DLMS/COSEM
• Local and remote firmware upgrade
• Multi tariff
• High Accuracy
• Remote Connect and disconnect with External Smart Switch (optional)

BOX 22kV
MV Metering Unit
(BOX 33kV)

• Up to 33 kV direct connection
• Prepayment and post-payment
• Wired or RF CIU
• Plug & play communication module
• Tamper proof
• Combined CT , PT, Meter
• Open standardized protocol: DLMS/COSEM
• Local and remote firmware upgrade
• Multi tariff
• High Accuracy
• Remote Connect and disconnect with
External Smart Switch (optional)

BOX 33kV
IHM-6300 FTU-Bell (Feeder Terminal Unit)
IHM-6300 FTU is designed based on advanced technology for management of T connection in MV feeders (10kV, 13kV, 20kV, 25kV, 35kV) to help utility company
for detection and isolation of fault in distribution network (FTU trip immediately to cut failure line and minimize outage effect).

• Compatible for MV feeder 11kV, 15kV, 20kV, 35kV


remote data acquisition
• Detect phase to phase failure and single phase ground
contact
• Reclosing, remote control, local control, locally button
operation and switch state acquisition.
• It supports multiple communication methods to facilitate
the automatic distribution system reconfiguration,
• Phase to phase short circuit protection, single phase
grounding protection
Casted Resin CT/VT
Vacuum Load Break Switch
Inhemeter provides Vacuum Circuit Breaker in different voltage level

IHM-6512-OVLS IHM-6524-OVLS IHM-6534-OVLS


Multi-function Meter

1010101010101010101010101

Power up

10101010101010101010101010

• Last gasp
• Over voltage
Smart View (AMI) • Low voltage
• Current unbalance
• Phase failure
• Reverse Phase sequence
• Low power factor
• Door opened and closed
• Communication error
Multi-function Meter

APP/SMS
Data Collector DCGJ-1A
SmartMDM
Raw information without process is not valuable and useful for utility
company, for this reason MDM system is Critical part of Smart
Metering System. Utilities are facing several serious challenges which
can be solved or at least eliminated by analyzing grid/energy data and
detecting problematic points and then taking remedy actions. Among
all problems those utilities are continuously suffering from, following
items can be mentioned like Energy loss (technical and commercial),
Over-loading of transformers and lines, High peak time consumption,
Poor management of outages and assets, Poor, late or not detecting
and managing events and alarms.
Inhemeter MDM System (SmartMDM) is enterprise level system deals with
metered data. SmartMDM processes data items, analyzes them and
generates high level and meaningful reports and information to top
managers, utility engineers and all other types of users. SmartMDM
usually deals with data regardless how and when they are collected, so
either they are gathered by AMM (Automatic Meter Management) or
entered manually can be processed by SmartMDM. SmartMDM is
application-oriented system which is developed to produce meaningful
information to users.
Transformer Management Solution
Inhemeter’s Distribution Transformer Management System (DTMS) represents the next evolutionary step in the smart grid development. DTMS
empower Distribution Optimization and Distribution Automation which further modernizes the grid. DTMS is designed based on advanced digital
measurement technology to measure and monitor real time parameter and operating status of transformer, collect transformer data, analysis power
quality , outage management and alarm abnormal event, automatically and remotely through communication system (GSM/GPRS, Ethernet, PLC/RF,
etc.), DTMS provides utilities with access to critical distribution optimization information from within the heart of the grid to improve grid efficiencies
and pinpoint power theft/losses for remediation. DTMS provides modern management tools for utility company to protection transformer from
overloading, high temperature and also help utility to measure and compensate power quality parameters deviations like power factor and voltage.
DTMS benefits:
• Detection most of transformers on the brink of collapse (overloaded) and performed proactive upgrades and redistributed secondary
connections to alleviate overloading from Utility company
• Improve outage (because normally change of transformer need 12 hours) and also with feeder monitoring and Last Gasp (in some utility up to
100,000 outage minutes)
• Improve PM and Asset management process
• Better management of Street light and decreasing total consumption up to 40%
• Improving delivered electricity Quality like voltage, power factor, load unbalancing
• Distribution Planning, utility company can recognized which transformer is overload and can make plan for extension of power network
DTMS High light
• Identify and lower utility losses
• Lessen outages and analysis
• Allow for preventive maintenance
• Accelerate restoration of power
• Report event like abnormal voltages, load,
temperature, oil level, unbalance, power factor,
• Support smart switch to connection and
disconnection of transformer
• Power quality measurement, analysis and
compensation
• Data concentrator for Smart Metering purpose
• Support PLC or RF to communicate for Smart
Metering
• Adoptable for single phase and three phase
transformer
• Manage Street lighting feeder

DTM Solution
IHM-6000 (TTU) Smart
Transformer Terminal Unit

IHM-6000 monitors transformer running state in real time (metering and monitoring the
transformer output power), meanwhile acting as Data Concentrator for gathering of
metering Data from Smart Meters in subsidiary of transformer. It provides the data
necessary to conduct preventive maintenance and proper network planning, ultimately
improving the stability of the power supply.
• Increase Low Voltage power network visibility
• Power quality measurement like Harmonic, THD, power factor, unbalance in
Current and voltage
• Abnormal events alerts for transformer and LV network
• High accuracy under all operational conditions: Class 0.5S
• Flexible input and output
• Open standardized protocol for metering and SCADA: DLMS/COSEM, RTU
MODBUS, DNP3.0, IEC 870-5-102 , GB 376.1, DL/T645
• Up to 32 odd harmonic and THD measurement
• Support OFDM, modulation for PLC communication to Smart meter, like PRIME, G3
or support fixed or Mesh RF for communication to Smart meter
• Support GSM/GPRS/3G, DSL, Fiber Optic for communication to central system
• Supports up to 1200 Smart meters
• Street Light feeder monitoring and Controlling
Street light
(Segment Control)
High Quality Split CT
• Rated current 75A to 6000A
• Maximum voltage 750V
• Accuracy < 0.5
• Output current 5A or 1A
• Standard IEC/EN60044-1, GB 1208, IEEE C57.13
• Insulation class, Class E
• Safety insulation EN61010-1 CAT III 600V
• Type: Aluminum Electrolytic Capacitor, low voltage capacitor
• Capacitance: 20kvar, 40(20+20)
• Rated Voltage: 450V
• Compensation method: Three phase compensation
• Weight: 7Kg
• Working temperature: -25°C to +55°C
• Power consumption:<2W

Smart Low Voltage Capacitor


Smart Low Voltage Circuit Breaker
• Type: Air • Rated insulation voltage: 1000V
• Fixed disconnection time: 23-32Ms • Rated ultimate short circuit breaking capacity(kA):
• Number of poles: 3,4 lcu=80kA 400V 50kA 690V lcs=lcw=50kA 690V 40kA 690V
• Rated voltage: 400V,690V • Mechanical life: 10000
• Rated current: 630,800,1000,1250,1600,2000 • Electric life: 500
Temperature Sensor

Magnetically-mounted temperature sensors make monitoring of top oil,


bottom oil, LTC oil and winding temperatures easy and reliable

• High Accuracy (<1°C Error)


• 100-ohm Platinum RTD Design
• Small Size (3/4" dia. - RTD5)
• High-Powered Mounting Magnet (RTD5)
• 60 Inch Cable (RTD5)
SCADA/DMS Central System

Smart DMS System Central system is complete solution to monitor, control and manage Distribution power network includes medium/high Voltage feeder,
Distribution substation and high voltage substation, the system provides real time monitoring and intelligent control (monitoring critical parameters of
distribution power network, locates and reports faults, automatically isolates faulty area, restores non-faulty area, provides remote control and reconfiguration,
etc.) Smart DMS is GIS based and user friendly system for monitoring and controlling of distribution power network. Smart DMS receiving information and alerts
from IEDs from power network, make process and analysis on received data and create related report for utility company and send related intelligent controlling
to IEDs. Smart DMS provides Standard interface to existing like OMS, IVR, and EMS system.
Smart DMS Functions

• SCADA function includes Data acquisition and process, Monitoring, alarm and event log, control (operation and closure), Real-time, communicate with
FTU, DTU, TTU, FCI and other terminals through the optical fiber, 3G, GPRS or wireless private network, to realize the real-time data acquisition and
remote-control function.
• Distribution network condition monitoring and Accident analysis, recall and holographic inversion
• Human Interface Machine includes IEC61970 CIM /XML import and export, Gallery of integrated graphics interface, Device management and Authority
management
• Feeder line automation function, Adopt the integrated FA mode, online topology analysis and generate the recovery plan, terminal layer can be set
through the flexible working mode of master station, Fault isolation with peer-to-peer communication mode, it can be finished in a terminal layer,
recovery of fault in short time (so it can ensure that the substation circuit breaker, reconnect successful), reduce
 FA (Feeder automation) function Based on the fault signals collected from FTU or fault indicator, determine the fault location and the
corresponding isolation and restoration scheme automatically in the real time.
 Fault location: Determine the fault location based on the fault signals collected by the FTU or fault indicators, as well as the real-time
switch state and the topological model of the power network.
 Fault isolation: Isolating the fault area from the distribution network through the remote control or manually
 Fault restoration: Restoration of power supply in non-fault areas through the remote control or manually
• Outage time and Perfect fault simulation system (users can customize any FA simulation plans, including the point of failure, failure time, failure types,
the FTU action and various parameters, such as communication status of distribution network)
• WEB subsystem includes Graphics and curve query, Particulars relating to the real-time query and alarm, Real time data query and Equipment
parameters query
• Distribution comprehensive information exchange that comply with IEC61970/IEC61968 standard and convenient communication interface function
between different systems
• Information processing and management function Data processing, statistical calculation, information storage, distribution network fault information
display and processing, fault information inquiry, historical event query, history data query, real time data view report function and so on.
Fault Isolation

Network Topology Analysis

Smart DMS Functions


Smart DMS Functions

Network Topology Analysis Graphical modeling


Smart DMS Functions

Estate Estimation Power Flow


Smart DMS Functions

Switching Order Management


Smart DMS Functions

Feeder Reconfiguration
Smart DMS Functions

Voltage VAR control Load forecasting


Power Grid
Rehabilitation
Obsolete and under pressure Power network is one of the
main source of system losses and unreliability. Proven
expertise of Inhemeter in the Engineering (electrical, civil and
structural), Procurement, construction and project
management of high Voltage substations, Distribution MV,
HV and LV power network, Distribution substation, etc.
enable Inhemeter to participate in projects as a turnkey or
EPC based. Inhemeter has undertaken projects ranging from
improving of existing Electricity Power Network and
development of new substations, employing innovative
technologies. Successful experiences in Malawi, Ivory Coast
are the best proof of Inhemeter capabilities in this field.
Scope of Services
Inhemeter’s Scope of service for Power network rehabilitation are:
• HV, MV and LV power network
• High voltage substation
• Distribution substation
• High Voltage Substation Automation
• Electrification of new customers
• Microgrid
• Distribution automation
MAKE GRID SMARTER
Thanks for your time

You might also like