You are on page 1of 4

S\LVA}{TA

METALAFRG
LAMP
EIALLASTS
For Outdoor Service, lndoor Service and lntegral Construction
This brochure describes the ultra-reliable Sylvania tuned to hermetically sealed capacitors providing you
line of ballasts for Metalarc Lamp applications. This with smaller, lighter, more efficient ballasts. In ad-
group of quality ballasts has been specifically de- dition, these ballasts utilize a unique Metalarc cir-
signed and tested for use with the new Sylvania cuit.
Metalarc 400 watt Lamp.
Single or double lamp designs are available in three
The Sylvania Metalarc Lamp not only offers higher types: Outdoor Weatherproof Cans, Indoor Cases,
efficiency and long lamp life, but most important, and Integral Construction. Starting at -20'F is
satisfles the need for good color rendition previously standard for each ballast. These specially designed
unavailable. To accomplish this a special ballast is ballasts will also start and satisfactorily operate H-33
required since a conventional mercury ballast will not mercury lamps.
operate the Metalare Lamp.
Electrical and mechanical specifications are shown
Sylvania Metalarc Lamp ballasts feature the Flexi- below for all Sylvania Metalarc types. Complete
core construction for long life. Major benefits re- technical assistance is readily available from your
sult from this unique Sylvania ballast construction. nearest Sylvania fleld engineer or by calling the
Vacuum impregnated coils are fltted to Sylvania Magnetic Components Department of Sylvania Elec-
Flexi-cores. The transformers are then precision tric Products Inc., Ipswich, Massachusetts.

OUTLINE DRAWNA
X

3 5/8
-\
-L-
(/'' Fi\
- \
)_, _. \ -_-/
r-)
2

;
il
I

\H_/ l
I l-- r -l
r12
I

l-:l I
I

.l
)_._ 2

tl I
@ e
l, ll l

/\/\ l*1 7/8-l - --

rNr-+ -r,.+:
AI i ll -lD
I

ltl _q
I lL_ -L___ _t-
|]oo-r
r*-B 'r o
=,;;;^,
C
LAI.IP TYPE ilotil 1{AL t I l.tE OPEN OUT LII,IE UN IT
& PRIMARY CATATOG t" I |lE CURRENI (IRCUIT \,1,tRtt'lc DrMENSrolts IIET
WATTAGE VOTTAGE NUMBER WAITS AMPS YOI.TAGE O IAGRA[.I ABCDEFG WT. tBS

WEATII ERPROOF l?0 x ?40 F4a-81259 455 4x2 290 z 13 5 28

CA}I 208 F48-81276 2.3 !{.l 13 5 28

I-400 wcll 27t F48-8r277 t.7 Il,l 13 5 28

Type: M400 480 F48-4r278 1.0 w 13 5 28

WEATH E RPROOT
'120
x 240 F48-8 I 32 I 885 8x4 290 x 13 6y1 40
(At{ 208 F48-81322 4.6 Y t3 6y2 40

2400 wolt 277 F48-8 I 323 3.5 Y t3 6y2 40

Type, M400 480 F48-8r324 2.0 Y t3 6y2 40

lN!00R (Ar'l 120 x 240 F47-81282 455 4x2 290 L 113/s 43/1 6ys12 2Vz 32
'l-400 watt 208 F47-81283 2.3 W t2
ll3/a 43/4 55/s 2y2 32

lype: M400 277 F47-81284 t.f w lt3/8 434 6ye t2 2t/z 32

480 F47-A12A5 1.0 w t13/8 434 6y8 t2 2t/z 32

INDOOR CAII 170 x 240 F47-8r 355 885 8x4 290 X 133/s 53/1 73/4 1213/t6 3 42

2-400 wott 208 F47-81 356 4.6 Y 133/s ssA 734 12t316 3 42

Iype: M400 2t7 F47-A1 357 3.5 Y 133/8 53/^ 73/4 1213/16 3 42

480 F47 -81 358 2.0 Y 133/s 53/4 734 121s/15 3 42

I I I{TEGRAI

l-400 wotl
Type, M400
120 x 24A
?08

277

480
F49-81260
F49-81279
F49-8 r
F49-8r281
2 80
455 4
2.3
1.7
1.0
x2 290 z
!l/
v'r

}4/
53/8 45/8 4y1
53/8 4s/8 4yl 6sAt
53/8 43/8 4y1 63hr
NA IIA NA }IA
63/te 13%2 32y32
131/s2 321A2
1'/r' 32tft7
I{A I{A
61L
6yl
6t/t
NA
l6
l6
't6

l6

I IITEGRAI 120 x 240 F49-81 363 885 8x4 290 x 71Ac 5t/a 5Vt 81At 13y32 32ys2 6114 30

2-400 woll 2s8 F49-81364 4.6 Y 71Ao 51/t SYa 81/* 13Y32 32Y32 61/1 30

Type: M400 277 F49-8 I 365 3.5 Y 71At 51/a 5r/o 81At 131/32 32|ft2 61/a 30

480 F49-81 366 2.0 Y ilA ilA NA }IA }IA NA NA 30

WIRING DIAGRAMS !}
z{i i'i

ii1

!*

;i.

-fr.!

trl
t!;
s
{
a!

a 5l

*
*€a?!:1?!1ffi1s*relHsltlrdq$*g-j*.?*{r{.f.sfi
BENEFITS OF
METALARC BALLASTS
REGULATION Meets A.S.A. minimum re-
quirements for regulation aL -+10/6 line volts.

ISOLATION The circuit used is of the auto-


transformer type. Normal precautions should be
taken to keep socket shell at ground potential.

CONSTRUCTION All Sylvania Mercury Bal-


lasts utiiize flexi-core construction. Flexi-core
Ballasts feature lighter weight and quiet cool
operation. The unique welded construction prac-
tically eliminates failures from vibration and
provides more efficient coil design. This means
greater reliability and longer life installations.

LOW START CURRENT The SYlvania


flexi-core current design keeps starting current
within a prescribed range during the warmup
period. Primary starting current is never allowed

SIA,
to exceed primary operating current. This type
of circuit does away with time delay relays, over-
size circuit breakers, and the larger gauge wiring
necessitated by high reactance type ballasts. This
type of bailast allows the use of a greater number
of lamps per circuit. lEiiEBAi' rEtEpnltvE e EIEcTBnAlcg @
OPEN AND SHORT-CIRCUIT PROTEC-
TION Occurrence of an open or short-circuit
condition in the lamp circuit produces correspond-
ing drop in primary current. This provides posi-
tive circuit protection.

UNDERWRITERS APPROVAL Items


F48-8I259 and F47-8I282 are UL approved. The
remaining types are pending approval.

RECTIFICATION By providing a capacitor


in series with the lamp, the possibility of ballast
destruction when operated on a rectifying lamp
is eliminated.

o
MAGNETIG COMPONENTS DEPT.
Sylvania Electric Products, lnc.
lpswich, Mass.

Printed in U.S.A,

You might also like