IMPORTANT: The VNX Storage Processor’s Service LAN ports are not always connected to an internal
switch. The VNX5200, VNX5400, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600 and VNX8000
Service LAN ports are internally switched, but the VNX5100, 5300 and 5500 are not internally switched.
IMPORTANT: See the CAUTION below before attaching any cables to the Service LAN ports.
The Service LAN of the two SPs in every VNX series storage system has the following factory-set IP
addresses:
SP-A: 128.221.1.250 (Service LAN port on SP-A SAN Management Module)
SP-B: 128.221.1.251 (Service LAN port on SP-B SAN Management Module)
Note: The storage system’s internal network (Service LAN) is mutually exclusive from the customer’s
main management ports on the Storage Processor (SP).
2. [ ] Navigate to your Network Connections and select your Local Area Connection (Figure 1), the
physical LAN cable port on your laptop.
3. [ ] On the TCP/IP Properties page, click the Use the following IP address radio button.
4. [ ] Set your laptop’s TCP/IP properties to the following IPs:
IP address: 128.221.1.249
Subnet mask 255.255.255.248
Default Gateway – 128.221.1.1
DNS server entries – leave blank
1
VNX_Service_LAN_port_setup.doc (1977.00 KB)
4/21/2017 10:42 AM
Last saved by nowlad
Note: The VNX5200, VNX5400, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600 and VNX8000
Service LAN ports are internally switched. A single connection to one SP will allow communication to
both SPs.
CAUTION: Never connect a switch or hub between the two Service LAN Ports on any
VNX5200, VNX5400, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600 and VNX8000 storage
system. Use a single cable for a connection with a hub or a direct connection from your laptop
to the Service LAN port. Connecting 2 cables with a Hub to both Service LAN ports will cause
a network storm and panic the array. If this problem occurs, promptly remove the Ethernet
cables. Reseat the Management Module if the port appears not to function. The Management
Modules are hot-swappable and may be removed and reseated without affecting the array’s
operation. Refer to Primus emc199379.
2
VNX_Service_LAN_port_setup.doc (1977.00 KB)
4/21/2017 10:42 AM
Last saved by nowlad
1. [ ] Connect the laptop network cable through a switch or hub to the Service LAN ports on the
VNX5100, VNX5300 or VNX5500 as shown in Figure 2 (left-side).
3
VNX_Service_LAN_port_setup.doc (1977.00 KB)
4/21/2017 10:42 AM
Last saved by nowlad
This Service LAN Interface connects to both SPA or SPB. The SP Service LAN port (RJ-45 with
wrench) location is shown in Figure 4.
2. [ ] Ping both SPs to verify connectivity.
1. [ ] To run Unisphere Manager, open a browser and type in 128.221.1.250 for a connection to
SPA or 128.221.1.251 for a connection to SPB.
2. [ ] Answer Yes to the Security Alert if necessary.
3. [ ] The Navisphere Login screen will appear.
4. [ ] Enter the user name and password.
5. [ ] Enter the NAT IP address to add the peer SPs IP address.
1. [ ] Navigate to: Start/ Programs/ EMC/ Unisphere/ Unisphere Client and open the Off Array
“Unisphere Client”. It is usually located here: C:\Program Files\EMC\UIClient
2. [ ] If JAVA scripts are disabled on your browser and you receive the message:
To help protect your security, Internet Explorer has restricted this file from
showing Active content that could access your computer. Click here for options -
and select Allow Blocked Content.
3. [ ] Your browser will then change and show “Start a new Unisphere Session”.
4. [ ] Click on Start.
5. [ ] You may get another request to “Allow Blocked Content”
6. [ ] Click to allow blocked content.
7. [ ] Accept any Certificate requests.