DROPCTRLERRINDSEQERR

MO GCELLSOFT

Parameter ID DROPCTRLERRINDSEQERR

Parameter Name Drop Optimize Err Ind[sequence error]

NE BSC6910

MML Command SET GCELLSOFT

Meaning Whether to optimize the call drops resulting from error indication (sequence err
"optimize" and 1 means "not optimize". If the value of this parameter is 0, the c
cause are not brought into the statistics of call drops.

IsKey NO

Mandatory NO

Feature ID GBFD-111004

Feature Name Radio Dedicated Channel Management

Value Type Interval Type

GUI Value Range 0~1

Enumeration Number/Bit N/A

Unit None

Actual Value Range 0~1

Default Value 1

Recommended Value 1

Initial Value Source Radio Planning (Internal planning)

Impact Cell

Parameter Relationship None

Access Read & Write

Service Interrupted After No (And no impact on the UE in idle mode)


Modification
Interruption Scope N/A

Interruption Duration(Min) N/A

Caution None

Validation of Modification The parameter modification has no impact on the equipment.

Impact on Radio Network None


Performance

Introduced in Version BSC6910 V100R015C00

Attribute Radio