You are on page 1of 3

kJ := 1000 J

Zagrevanje soka pre II saturacije 1st postojeći pločasti zagrevač GEA 192K
IV brid

tonne
tonne mp := 8.238
m1 := 406.243 hr
hr
kJ
Tbrid := 103.6 °C r := 2246.92 ⋅
kJ kg
cp1 := 3.75505
kg⋅ K W 2
k := 1617 P := 250 m
2
T1 := 83.4°C m ⋅K
T1 = 83.4 ⋅ °C

polazna procena
T2 := 85 °C

( Tbrid − T2) − ( Tbrid − T1) ⎤


T2 := root ⎡⎢m1⋅ cp1⋅ ( T2 − T1) − k ⋅ P⋅ ⎡⎢ ⎤
⎥ , T2⎥
Tbrid − T2 ⎞
⎢ ⎢ ln⎛⎜ ⎟ ⎥ ⎥
⎣ ⎣ ⎝ Tbrid − T1 ⎠ ⎦ ⎦

T2 = 95.819 ⋅ °C temperatura nakon pločastog


izmenjivača

⎡ ( Tbrid − T2 ) − ( Tbrid − T1 )⎤
⎢ Tbrid − T2 ⎞ ⎥
⎢ ln⎛⎜ ⎟ ⎥
mp := k ⋅ P⋅
⎣ ⎝ Tbrid − T1 ⎠ ⎦ mp = 8.43146 ⋅
tonne
r hr potrebna količina pare
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
prepravka na V brid
Zagrevanje soka pre II saturacije 1st postojeći pločasti zagrevač GEA 192K

tonne
m1 := 406.243
hr
kJ
Tbrid := 92.5 °C r := 2276.097⋅
kJ kg
cp1 := 3.75505
kg⋅ K W 2
k := 2200 P := 250m
2
T1 := 83.4 °C m ⋅K
T1 = 83.4⋅ °C

polazna procena
T2 := 85 °C

( Tbrid − T2 ) − ( Tbrid − T1 ) ⎤
T2 := root⎡⎢m1⋅ cp1⋅ ( T2 − T1 ) − k ⋅ P⋅ ⎡⎢ ⎤
⎥ , T2⎥
Tbrid − T2 ⎞
⎢ ⎢ ln⎛⎜ ⎟ ⎥ ⎥
⎣ ⎣ ⎝ Tbrid − T1 ⎠ ⎦ ⎦

T2 = 90.015⋅ °C temperatura nakon pločastog


izmenjivača

⎡ ( Tbrid − T2 ) − ( Tbrid − T1 )⎤
⎢ Tbrid − T2 ⎞ ⎥
⎢ ln⎛⎜ ⎟ ⎥
mp := k ⋅ P⋅
⎣ ⎝ Tbrid − T1 ⎠ ⎦ mp = 4.43338 ⋅
tonne
r hr potrebna količina pare
Proračun para

Pritisak pare 0,77 bar


Temperatura pare 92,5 bar
Gustina pare 0,46 kg/m3
Protok pare 4,43 t/h
Protok pare 2,66 m3/s
Brzina pare 40 m/s
Površina poprečnog preseka 0,07 m2
Unutrašnji presek cevovoda 291,10 mm