You are on page 1of 11

DESIGN OF ISOLATED SQUARE FOOTING

Pu 384 check for load transfe


SBC 150
safety factor 1
column size
b 350 mm
D 350 mm
fck 20 N/mm2
fy 500 N/mm2
clear cover 50 mm
perectage of selfweight 10 %
SWt. Of footing 38.4
total load 422.4 lower fbr
for earth quake, increase the SBC of soil by 50%
Area of footing 2.816

for square footing


L=W 1.678094157
provided L=W 1.7

net soil pressure qu 0.204545455 N/mm2

S1 FOR CALCULATING 'd' 343.2465321 equation


s2 343246.5321 2

Assume Pt for Concrete grade


Pt 0.25
Tc from code, table 19 0.36 N/mm2
for one way shear
Vc1 604.1138965 equation 2

calculated 'd' 362.3188406 mm


NOTE therefore provide 'd' 365 mm

two way shear


Vu2 471431.25 N
Ks 1
Tc 1.118033989
S3 4.472135955
S4 1565.247584 for d alone

calculated 'd' fro two way shear


d' 193.8363217 mm
compare d calculated from one way and two way shear and take
the suitable value of depth accordingly
dia of bar 12
over all depth of footing D 421 mm
effective depth 'd' 365 mm < 365
design of reinforcement
l1 664.0470785
Mu 75.67874183
Mu/bd2 0.33851027
NOTE refer SP:16 table2,pg.48, interpolate the value of Pt and if it is less
than 0.25 then assumed for one way shear or take 0.25

Pt 0.25
Ast req 912.5 mm2
provided dia of bar 12 mm
spacing, Sv 123.9422854 120 mm c/c

Therefore provide 12 @ 120 mmc/c


check for load transfer at the base of column

Pu 384
A2 122500 mm2
A1 2816000 mm2
(A2/A2)^.5 1
(A1/A1)^.5 4.794555 NOTE: it the value is greater than 2, take 2
provided 2 NOTE: 2 is taken if only the former one is greater
fbr1 9 For column face
fbr2 18
compare the above two values for fbr. Take the lower value
lower fbr 9
Fbr 1102.5

NOTE: if the final Fbr value is lesser than the Pu then extend the column main bar at a
90 degree resting on mesh to transfer the extra loads.
DESIGN OF ISOLATED SQUARE FOOTING

Pu 869 check for load transfe


SBC 150
safety factor 1.5
column size
b 350 mm
D 350 mm
fck 20 N/mm2
fy 500 N/mm2
clear cover 50 mm
perectage of selfweight 10 %
SWt. Of footing 86.9
total load 955.9 lower fbr
for earth quake, increase the SBC of soil by 50%
Area of footing 6.372666667

for square footing


L=W 2.524414123
provided L=W 2.5

net soil pressure qu 0.20856 N/mm2

S1 FOR CALCULATING 'd' 521.4 equation


s2 521400 2

Assume Pt for Concrete grade


Pt 0.25
Tc from code, table 19 0.36 N/mm2
for one way shear
Vc1 900 equation 2

calculated 'd' 366.8214436 mm


NOTE therefore provide 'd' 370 mm

two way shear


Vu2 1195382.496 N
Ks 1
Tc 1.118033989
S3 4.472135955
S4 1565.247584 for d alone

calculated 'd' fro two way shear


d' 370.8210806 mm
compare d calculated from one way and two way shear and take
the suitable value of depth accordingly
dia of bar 12
over all depth of footing D 410 mm
effective depth 'd' 354 mm < 370
design of reinforcement
l1 1075
Mu 301.2714375
Mu/bd2 0.96163758
NOTE refer SP:16 table2,pg48, interpolate the value of Pt and if it is less
than 0.25 then assumed for one way shear or take 0.25

Pt 0.25
Ast req 885 mm2
provided dia of bar 12 mm
spacing, Sv 127.7935994 130 mm c/c

Therefore provide 12 @ 130 mmc/c


check for load transfer at the base of column

Pu 869
A2 122500 mm2
A1 6250000 mm2
(A2/A2)^.5 1
(A1/A1)^.5 7.142857 NOTE: it the value is greater than 2, take 2
provided 2 NOTE: 2 is taken if only the former one is greater
fbr1 9 For column face
fbr2 18
compare the above two values for fbr. Take the lower value
lower fbr 9
Fbr 1102.5

NOTE: if the final Fbr value is lesser than the Pu then extend the column main bar at a
90 degree resting on mesh to transfer the extra loads.
mm
DESIGN OF ISOLATED SQUARE FOOTING

Pu 389 check for load transfe


SBC 150
safety factor 1.5
column size
b 350 mm
D 350 mm
fck 20 N/mm2
fy 415 N/mm2
clear cover 50 mm
perectage of selfweight 10 %
SWt. Of footing 38.9
total load 427.9 lower fbr
for earth quake, increase the SBC of soil by 50%
Area of footing 2.852666667

for square footing


L=W 1.688983915
provided L=W 2

net soil pressure qu 0.145875 N/mm2

S1 FOR CALCULATING 'd' 291.75 equation


s2 291750 2

Assume Pt for Concrete grade


Pt 0.25
Tc from code, table 19 0.36 N/mm2
for one way shear
Vc1 720 equation 2

calculated 'd' 288.3617494 mm


NOTE therefore provide 'd' 339 mm

two way shear


Vu2 514250.0741 N
Ks 1
Tc 1.118033989
S3 4.472135955
S4 1565.247584 for d alone

calculated 'd' fro two way shear


d' 206.5950895 mm
compare d calculated from one way and two way shear and take
the suitable value of depth accordingly
dia of bar 10
over all depth of footing D 390 mm
effective depth 'd' 335 mm < 339
design of reinforcement
l1 825
Mu 99.28617188
Mu/bd2 0.442353183
NOTE refer SP:16 table2,pg.48, interpolate the value of Pt and if it is less
than 0.25 then assumed for one way shear or take 0.25

Pt 0.128
Ast req 428.8 mm2 AST PROVIDED=
provided dia of bar 12 mm
spacing, Sv 263.7531144 150 mm c/c

Therefore provide 12 @ 150 mmc/c


check for load transfer at the base of column

Pu 389
A2 122500 mm2
A1 4000000 mm2
(A2/A2)^.5 1
(A1/A1)^.5 5.714286 NOTE: it the value is greater than 2, take 2
provided 2 NOTE: 2 is taken if only the former one is greater
fbr1 9 For column face
fbr2 18
compare the above two values for fbr. Take the lower value
lower fbr 9
Fbr 1102.5

NOTE: if the final Fbr value is lesser than the Pu then extend the column main bar at a
90 degree resting on mesh to transfer the extra loads.
mm

AST PROVIDED= 113.04