You are on page 1of 2

METERING

TRIVECTOR METER – ER300P

◆ Class of Accuracy: 1.0 / 0.5S / 0.2S ◆ Up to three Maximum Demand registers.


◆ High Surge Voltage withstand ◆ Tamper/ Fraud Detection
capability up to 8 kV. ◆ Multiple Tariff Capability
U K AS
◆ Four Quadrant Energy Measurement. ◆ Self-Diagnostics

LARSEN & TOUBRO LIMITED


TRIVECTOR METER – ER300P
TECHNICAL SPECIFICATIONS
Accuracy Tamper Recording Display
Class 1.0......... IS 13779 / IEC 61036 ◆ Logs the following TTampers
ampers ◆ Custom built LCD with Backlight.
Class 0.5S / 0.2S... IEC 60687
0.2S...IEC with Date & Time of Occurrence ◆ 8 digit 7 segment display for
IS 14697/CBIP-88 & Restoration parameters
Electrical ◆ Identifier for parameters
■ Missing Potential
◆ Voltage (-30 % to + 20 %) ■ Missing Current ◆ 3 Display modes
■ 3 Phase 4 Wire…….…63.5 V (L-N) ■ Cur
Currr ent & Voltage Unbalance
Voltage ◆ Auto Scroll Display
■ 3 Phase 4 Wire……….240 V (L-N) ■ Current Reversal ◆ UP-DN Keys for scrolling
■ 3 Phase 3 Wire……….110 V (L-L) Communication
◆ Snapshots of VV,, I, Power Factor
Factor,,
◆ Current Energy at the time of tamper
Energy tamper.. ◆ Optical port as per IEC 1107
■ CT operated (Optional)
I b ……… 1A, 5A ◆ RS 232 port (optional)
I max…..200% of I b
◆ Flags for Phase Sequence, ◆ RS 485 using MODBUS protocol
Cur
Currr ent Reversal, Voltage
Voltage (optional)
■ Whole Current Missing, Current Missing and
I b....5A, 10A, 20A, 50A other T ampers.
Tampers. Data Security
I max…Up to 600% of Ib ◆ Data storage in Non Volatile Memor
Volatile Memoryy
Load Survey
◆ Frequency Range 50Hz + 55% % ◆ 2 levels of Password :-
◆ 183 parameter days at 30 min
Measured Energy Values integration period ■ For Data Reading
◆ 4 Quadrant Measurement of ◆ Programmable Features :- ■ For Programming
kWh, kVARh,kV
kVARh,kVAh
ARh,kVAh
■ Up to 4 energies can be selected Self Diagnostics
Other Measured & Displayed
Values ■ Integration period programmable ◆ Anomaly string indicating :-
from1-60 mins (optional)
◆ Power……kW
Power……kW,, kV AR,kV
kVAR,kV A
AR,kVA ■ Program Memory error
◆ Voltages & Cur
Currr ents
◆ Power Factor Maximum Demand (MD) Register ■ EEPROM error
◆ Frequency ◆ Up to 3 MD registers can be ■ RTC error
programmed
Time of Use (TOD) ◆ Integration periods programmable Output Device
◆ Up to 8 Tarif
arifff Registers
Tarif from 1 to 60 minutes. ◆ LEDs with output proportional to
◆ Up to 10 defined slots can be ◆ Reset: auto/manual/through MRI kWh,kVARh
kWh,kVARh
programmed ◆ Rising Demand on display

LARSEN & TOUBRO LIMITED


METERING AND PROTECTION SYSTEMS
Works…..KIADB Indl. Estate, Hebbal, Hootagalli, Mysore-570018. Ph: (0821) 402561. Fax: (0821) 402172.
◆ New Delhi: Ph: (011) 25177883. Fax: (011) 25438624 ◆ Bangalore: Ph: (080) 5587825. Fax: (080) 5596397 ◆ Kolkata: Ph:(033) 22823302.
Fax: (033) 22821025 ◆Chandigarh: Ph:(0172) 370131. Fax:(0172) 792764 ◆Mumbai: Ph:(022) 28581634. Fax:(022) 28582020
◆ Chennai: Ph:(044) 28462055 Fax: (044) 28462102.
Visit us at www.lntmps.com
Product improvement is a continuous process. For the latest information, please contact any of our offices as listed above