You are on page 1of 1

ICD-S/U to Target Connections

ICD Target Pin Description

1 6 Pin B3 on target PIC® MCU or PIC® DSC - C Aware Real-Time


Debugging (Optional)

2 5 Pin B6 on target PIC® MCU or PIC® DSC - ICSP Clock

3 4 Pin B7 on target PIC® MCU or PIC® DSC - ICSP Data

4 3 Ground (GND)

5 2 Power (V )
DD

The ICD-S is powered by this pin at +3.3V or +5.0V.


The ICD-U uses this pin to pull-up signals and power the
target PIC® MCU or PIC® DSC if the proper jumpers are
set.

6 1 MCLR

Connect to target PIC® MCU or PIC® DSC and pull up to


+5.0V on target board with a 47K resistor. The ICD-S/U
will drive this pin with +13V during programming, or
+5.0V while programming a PIC18J® MCU, PIC24®
MCU, or dsPIC® DSC. No capacitor should be used on
MCLR or it will cause programming problems with the
ICD-S/U.