You are on page 1of 5

SLAB DESIGN FOR S7 AND S9 PANEL :

REFERING TO REINFORCED CONCRETE SLABS BY R.PARK & W.L. GAMBLE

4
6.705

DEAD LOAD = 0.15 x 25 = 3.75 KN/m2


FLOOR FINISH = 1.5 KN/m2 3 6.53 3
LIVE LOAD = 2 KN/m2
A
TOTAL LOAD = 7.25 KN/m2 3.765 4.35
2 2
TOTAL FACTORED LOAD Wu = 10.875 KN/m2
b-b
DESIGN MOMENTS FOR UNIFORM LOAD : 2.41 1 a 4 B 1
!
a 4.35 6.53
SEGMENT A :
0.4 Wu = 4.35 KN/m2 STRIP 4- 4
0.6 Wu = 6.53 KN/m2 STRIP 3- 3 2
3.43
SEGEMNT B
0.6 Wu = 6.53 KN/m2 STRIP 2- 2
0.4 Wu = 4.35 KN/m2 STRIP 1- 1
2

1 1
STRIP 1-1 : 2.41
4.35 B
FREE MAX -VE MOMENT = WL2/ 2 = 12.63 KNm/m 6.53
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN 2
PROP REACTION = 2.621 KN/m 3.43

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 2.621 Xo - 4.35 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.60 m

MAX +VE MOMENT = 0.79 KNm/m


MAX -VE MOMENT = -6.32 KNm/m

STRIP 2-2 :
FREE MAX -VE MOMENT = WL2/ 2 = 38.38 KNm/m
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN
PROP REACTION = 5.595 KN/m

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 5.595 Xo - 6.53 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.86 m
4
MAX +VE MOMENT = 2.40 KNm/m
MAX -VE MOMENT = -5.46 KNm/m

STRIP 3-3 :
6.53
STATIC MOMENT = WL2/ 8 = 36.67 KNm/m 3 3
3.765 A
MAX -VE MOMENT = 0.6 Mu = 22.00 KNm/m 4.35
MAX +VE MOMENT = 0.4 Mu = 14.67 KNm/m
4
6.705
STRIP 4-4 :
FREE MAX -VE MOMENT = WL2/ 2 = 30.83 KNm/m
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN
PROP REACTION = 4.094 KN/m

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 4.094 Xo - 4.35 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.94 m

MAX +VE MOMENT = 1.93 KNm/m


MAX -VE MOMENT = -15.4 KNm/m

STRONG BAND b-b : 11.65 KN/m

3.43
BAND WIDTH = 0.3 m
BAND LOAD = 4.094 + 5.595 + 10.875 x 0.30 - 4.35 x 0.3
(PROP REACTION) (PROP REACTION) = 11.65 KN/m
MAX +VE MOMENT = 9 W L2 = 9.63
128
MAX -VE MOMENT = W L2 = 17.13
8

STRONG BAND a-a : 4.58 KN/m

2.41
BAND WIDTH = 0.3 m
BAND LOAD = 2.621 + 10.875 x 0.3 - 4.35 x 0.3 = 4.58 KN/m
(PROP REACTION)
MAX +VE MOMENT = 9 W L2 = 1.87
128
MAX +VE MOMENT = W L2 = 3.32
8
REINFORCEMENT CALCULATIONS :
DEPTH D = 150 mm Breadth = 1000 fck= 20 fy = 415
EFFECTIVE DEPTH dx = 130 mm dy = 120 mm

IN X- DIRECTION : 10 DIA
SEGEMENT A : Mu Mu/bd 2
pt Ast spacing
SAGGING MOMENT = 14.67 0.87 0.254 330.0 238.0

HOGGING MOMENT = 22.00 1.30 0.393 510.5 153.8

SEGEMENT B :
SAGGING MOMENT = 0.79 0.05 0.200 260.0 302.1

HOGGING MOMENT = 6.32 0.37 0.200 260.0 302.1

IN BAND a-a :
SAGGING MOMENT = 1.87 0.11 0.200 260.0 302.1

HOGGING MOMENT = 3.32 0.20 0.200 260.0 302.1

IN Y- DIRECTION :
SEGEMENT A :
SAGGING MOMENT = 1.93 0.13 0.200 240.0 327.3

HOGGING MOMENT = 15.42 1.07 0.318 381.0 206.1

SEGEMENT B :
SAGGING MOMENT = 5.46 0.38 0.200 240.0 327.3

HOGGING MOMENT = 2.40 0.17 0.200 240.0 327.3

IN BAND b-b :
SAGGING MOMENT = 9.63 0.67 0.200 240.0 327.3

HOGGING MOMENT = 17.13 1.19 0.356 427.0 183.9