SLAB NO = S1

GRADE OF CONCRETE 20 MPa


GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 4.5 m
SHORTER SPAN IN METERS= 3.7 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.216
EDGE CONDITION :
ONE SHORT EDGE CONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0
ax2= 0.06
ay1= 0.057
ay2= 0.043

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0 x 10.875 x 3.7 2 0 0 0.12 150 10 524
Mx(+ve) = 0.06 x 10.875 x 3.7 2 8.929 0.571 0.164 204.84 10 383 200
My(-ve) = 0.057 x 10.875 x 3.7 2 8.486 0.642 0.185 212.58 10 369
My(+ve) = 0.043 x 10.875 x 3.7 2 6.402 0.484 0.138 158.75 10 495 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 125.553 MPa
Modification factor (From Fig 4 IS 456-2000) 3.175
Effective Depth Required = Lx/(20*M.F) 58.275 mm O.K.
SLAB NO = S2
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 4.73 m
SHORTER SPAN IN METERS= 3.43 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.379
EDGE CONDITION :
ONE SHORT EDGE CONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0
ax2= 0.0697
ay1= 0.057
ay2= 0.043

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0 x 10.875 x 3.43 2 0 0 0.12 150 10 524
Mx(+ve) = 0.07 x 10.875 x 3.43 2 8.923 0.571 0.164 204.7 10 384 200
My(-ve) = 0.057 x 10.875 x 3.43 2 7.293 0.551 0.158 181.62 10 432
My(+ve) = 0.043 x 10.875 x 3.43 2 5.502 0.416 0.12 138 10 569 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 125.468 MPa
Modification factor (From Fig 4 IS 456-2000) 3.177
Effective Depth Required = Lx/(20*M.F) 53.975 mm O.K.
SLAB NO = S3
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 3.515 m
SHORTER SPAN IN METERS= 2.73 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.288
EDGE CONDITION :
TWO ADJACENT EDGES DISCONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0.0644
ax2= 0.0485
ay1= 0.047
ay2= 0.035

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0.064377 x 10.875 x 2.73 2 5.218 0.334 0.12 150 10 524
Mx(+ve) = 0.049 x 10.875 x 2.73 2 3.931 0.252 0.12 150 10 524 200
My(-ve) = 0.047 x 10.875 x 2.73 2 3.809 0.288 0.12 138 10 569
My(+ve) = 0.035 x 10.875 x 2.73 2 2.837 0.214 0.12 138 10 569 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 91.941 MPa
Modification factor (From Fig 4 IS 456-2000) 4.836
Effective Depth Required = Lx/(20*M.F) 28.224 mm O.K.
SLAB NO = S4
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 4.515 m
SHORTER SPAN IN METERS= 4.11 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.099
EDGE CONDITION :
ONE LONG EDGE DISCONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0.0439
ax2= 0.0329
ay1= 0.037
ay2= 0.028

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0.043898 x 10.875 x 4.11 2 8.064 0.516 0.147 184.35 10 426
Mx(+ve) = 0.033 x 10.875 x 4.11 2 6.049 0.387 0.12 150 10 524 200
My(-ve) = 0.037 x 10.875 x 4.11 2 6.797 0.514 0.147 168.87 10 465
My(+ve) = 0.028 x 10.875 x 4.11 2 5.144 0.389 0.12 138 10 569 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 91.941 MPa
Modification factor (From Fig 4 IS 456-2000) 4.836
Effective Depth Required = Lx/(20*M.F) 42.491 mm O.K.
SLAB NO = S5
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 5.205 m
SHORTER SPAN IN METERS= 4.11 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.266
EDGE CONDITION :
ONE LONG EDGE DISCONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0.0553
ax2= 0.0423
ay1= 0.037
ay2= 0.028

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0.055321 x 10.875 x 4.11 2 10.163 0.65 0.187 234.34 10 335
Mx(+ve) = 0.042 x 10.875 x 4.11 2 7.774 0.498 0.142 177.52 10 442 200
My(-ve) = 0.037 x 10.875 x 4.11 2 6.797 0.514 0.147 168.87 10 465
My(+ve) = 0.028 x 10.875 x 4.11 2 5.144 0.389 0.12 138 10 569 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 108.809 MPa
Modification factor (From Fig 4 IS 456-2000) 3.83
Effective Depth Required = Lx/(20*M.F) 53.653 mm O.K.
SLAB NO = S6
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 5.145 m
SHORTER SPAN IN METERS= 3.73 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.379
EDGE CONDITION :
ONE SHORT EDGE DISCONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0.0542
ax2= 0.0406
ay1= 0.037
ay2= 0.028

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0.054174 x 10.875 x 3.73 2 8.197 0.525 0.15 187.48 10 419
Mx(+ve) = 0.041 x 10.875 x 3.73 2 6.141 0.393 0.12 150 10 524 200
My(-ve) = 0.037 x 10.875 x 3.73 2 5.598 0.423 0.12 138.3 10 568
My(+ve) = 0.028 x 10.875 x 3.73 2 4.236 0.32 0.12 138 10 569 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 91.941 MPa
Modification factor (From Fig 4 IS 456-2000) 4.836
Effective Depth Required = Lx/(20*M.F) 38.562 mm O.K.
DESIGN OF ONEWAY SLAB
SLAB NO = S8
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 7.475 m
SHORTER SPAN IN METERS= 2.63 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 2.842
LIVE LOAD = 2 kN/m2
FLOOR FINISH = 1.5 kN/m2
PARTITIONS = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED DEAD LOAD Wd = 7.875 kN/m2
TOTAL FACTORED LIVE LOAD Wl = 3 kN/m2

EFF.DEPTH ALONG SHORT SPAN = 130 mm

SUPPORT MOMENT = (Wd x Lx^2/10) + (Wl x Lx^2/9) = 7.7527 KN-m


SPAN MOMENT = (Wd x Lx^2/12) + (Wl x Lx^2/10) = 6.6143 KN-m

BENDING MOMENT Mu/bd2 pt Ast Dia of ReinSpacing Spacing(P)


Msupport= 7.753 0.459 0.131 169.8 10 462
Mspan = 6.614 0.391 0.12 156 10 503 200

CHECK FOR DEFLECTION :


Area of Steel at mid span= 392.699 sqmm
Percentage of Steel at Mid Span Pt = 0.302 %
Stress in Steel at Service =0.58(As(R)/As(P)) = 95.618 MPa
Modification factor (M.F)(From Fig 4 IS 456-2000) 4.809
Effective Depth Required = Lx/(20*M.F) 27.347 mm
SLAB NO = S10
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS "a" = 3.945 m
SHORTER SPAN IN METERS "b" = 4.545 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 0.868
LIVE LOAD = 2 kN/m2
FLOOR FINISH = 1.5 kN/m2
PARTITIONS = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


x=0, y=0 Mx(+ve) = 0.251 x 10.875 x 4.545 2 9.398 0.601 0.173 216.01 10 363 225
x=0, y=b Mx(-ve) = 0.207 x 10.875 x 4.545 2 7.75 0.586 0.168 193.45 10 406 225
x=+ or - a/ My(+ve) = 0.4048 x 10.875 x 4.545 2 15.156 1.146 0.342 393.04 10 200 200

a Y

A TOP A X
B BOTTOM a/2 a/2
C TOP b

C B C
SLAB NO = S11
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 5.675 m
SHORTER SPAN IN METERS= 3.945 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.439
EDGE CONDITION :
TWO ADJACENT EDGES DISCONTINUOUS
BENDING MOMENT COEFFICIENTS
ax1 = 0.0725
ax2= 0.0542
ay1= 0.047
ay2= 0.035

LIVE LOAD = 2 kN/m2


FLOOR FINISH = 1.5 kN/m2
PARTITIONS/SUNKEN = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 10.875 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


Mx(-ve) = 0.072541 x 10.875 x 3.945 2 12.277 0.786 0.229 285.65 10 275
Mx(+ve) = 0.054 x 10.875 x 3.945 2 9.166 0.587 0.168 210.48 10 373 200
My(-ve) = 0.047 x 10.875 x 3.945 2 7.955 0.601 0.173 198.75 10 395
My(+ve) = 0.035 x 10.875 x 3.945 2 5.924 0.448 0.127 146.56 10 536 225

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58(As(R)/As(P)) = 129.013 MPa
Modification factor (From Fig 4 IS 456-2000) 3.066
Effective Depth Required = Lx/(20*M.F) 64.331 mm O.K.
CANTILEVER SLAB :
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS= 3.55 m
SHORTER SPAN IN METERS= 1.315 m
ASSUMED THICKNESS OF SLAB = 150 mm
b/a = 0.37

LIVE LOAD = 3kN/m2


FLOOR FINISH = 1.5kN/m2
STEPS = 0kN/m3
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 12.375 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm
FACTORED WALL LOAD MOMENT = 0KN./m
BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)
Mx(-ve) = 0.5 x 12.375 x 1.315 2 10.7 0.685 0.198 247.28 10 317 200

CHECK FOR DEFLECTION


Area of Steel at mid span= 392.699 Sq.mm
Percentage of Steel at Mid Span = 0.314
Stress in Steel at Service =0.58 fy (As(R)/As(P)) = 151.566 MPa
Modification factor (From Fig 4 IS 456-2000) 2.508
Effective Depth Required = Lx/(7*M.F) 74.91 mm O.K.
SLAB NO = S12
GRADE OF CONCRETE 20 MPa
GRADE OF REINFORCEMENT 415 MPa
LONGER SPAN IN METERS "a" = 3.43 m
SHORTER SPAN IN METERS "b" = 1.73 m
ASSUMED THICKNESS OF SLAB = 150 mm
Ly/Lx = 1.983
LIVE LOAD = 3 kN/m2
FLOOR FINISH = 1.5 kN/m2
PARTITIONS = 0 kN/m2
DEAD LOAD = 3.75 kN/m2
TOTAL FACTORED LOAD = 12.375 kN/m2
EFF.DEPTH ALONG SHORT SPAN = 125 mm
EFF.DEPTH ALONG LONG SPAN = 115 mm

BENDING MOMENT Mu Mu/bd2 pt Ast Dia of ReinSpacing Spacing(p)


x=0, y=0 Mx(+ve) = 1.226 x 12.375 x 1.73 2 7.568 0.484 0.138 172.66 10 455 225
x=0, y=b Mx(-ve) = 0.605 x 12.375 x 1.73 2 3.735 0.282 0.12 138 10 569 225
x=+ or - a/ My(+ve) = 1.568 x 12.375 x 1.73 2 9.679 0.732 0.212 243.9 10 322 200

a Y

A TOP A X
B BOTTOM a/2 a/2
C TOP b

C B C
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
Spacing(p)
SLAB DESIGN FOR S7 AND S9 PANEL :
REFERING TO REINFORCED CONCRETE SLABS BY R.PARK & W.L. GAMBLE

4
6.705

DEAD LOAD = 0.15 x 25 = 3.75 KN/m2


FLOOR FINISH = 1.5 KN/m2 3 6.53 3
LIVE LOAD = 2 KN/m2
A
TOTAL LOAD = 7.25 KN/m2 3.765 4.35
2 2
TOTAL FACTORED LOAD Wu = 10.875 KN/m2
b-b
DESIGN MOMENTS FOR UNIFORM LOAD : 2.41 1 a 4 B 1
!
a 4.35 6.53
SEGMENT A :
0.4 Wu = 4.35 KN/m2 STRIP 4- 4
0.6 Wu = 6.53 KN/m2 STRIP 3- 3 2
3.43
SEGEMNT B
0.6 Wu = 6.53 KN/m2 STRIP 2- 2
0.4 Wu = 4.35 KN/m2 STRIP 1- 1
2

1 1
STRIP 1-1 : 2.41
4.35 B
FREE MAX -VE MOMENT = WL2/ 2 = 12.63 KNm/m 6.53
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN 2
PROP REACTION = 2.621 KN/m 3.43

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 2.621 Xo - 4.35 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.60 m

MAX +VE MOMENT = 0.79 KNm/m


MAX -VE MOMENT = -6.32 KNm/m

STRIP 2-2 :
FREE MAX -VE MOMENT = WL2/ 2 = 38.38 KNm/m
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN
PROP REACTION = 5.595 KN/m

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 5.595 Xo - 6.53 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.86 m
4
MAX +VE MOMENT = 2.40 KNm/m
MAX -VE MOMENT = -5.46 KNm/m

STRIP 3-3 :
6.53
STATIC MOMENT = WL2/ 8 = 36.67 KNm/m 3 3
3.765 A
MAX -VE MOMENT = 0.6 Mu = 22.00 KNm/m 4.35
MAX +VE MOMENT = 0.4 Mu = 14.67 KNm/m
4
6.705
STRIP 4-4 :
FREE MAX -VE MOMENT = WL2/ 2 = 30.83 KNm/m
IF THE PROP REACTION REDUCES THE MAX - VE MOMENT TO
0.5 TIMES -VE MOMENT, THEN
PROP REACTION = 4.094 KN/m

POSITIVE MOMENT PER UNIT WIDTH IN THE STRIPS


M= 4.094 Xo - 4.35 Xo 2 WHERE Xo IS THE DISTANCE FROM THE PROPPED END
2
dM/dXo = 0 Xo = 0.94 m

MAX +VE MOMENT = 1.93 KNm/m


MAX -VE MOMENT = -15.4 KNm/m

STRONG BAND b-b : 11.65 KN/m

3.43
BAND WIDTH = 0.3 m
BAND LOAD = 4.094 + 5.595 + 10.875 x 0.30 - 4.35 x 0.3
(PROP REACTION) (PROP REACTION) = 11.65 KN/m
MAX +VE MOMENT = 9 W L2 = 9.63
128
MAX -VE MOMENT = W L2 = 17.13
8

STRONG BAND a-a : 4.58 KN/m

2.41
BAND WIDTH = 0.3 m
BAND LOAD = 2.621 + 10.875 x 0.3 - 4.35 x 0.3 = 4.58 KN/m
(PROP REACTION)
MAX +VE MOMENT = 9 W L2 = 1.87
128
MAX +VE MOMENT = W L2 = 3.32
8
REINFORCEMENT CALCULATIONS :
DEPTH D = 150 mm Breadth = 1000 fck= 20 fy = 415
EFFECTIVE DEPTH dx = 130 mm dy = 120 mm

IN X- DIRECTION : 10 DIA
SEGEMENT A : Mu Mu/bd 2
pt Ast spacing
SAGGING MOMENT = 14.67 0.87 0.254 330.0 238.0

HOGGING MOMENT = 22.00 1.30 0.393 510.5 153.8

SEGEMENT B :
SAGGING MOMENT = 0.79 0.05 0.200 260.0 302.1

HOGGING MOMENT = 6.32 0.37 0.200 260.0 302.1

IN BAND a-a :
SAGGING MOMENT = 1.87 0.11 0.200 260.0 302.1

HOGGING MOMENT = 3.32 0.20 0.200 260.0 302.1

IN Y- DIRECTION :
SEGEMENT A :
SAGGING MOMENT = 1.93 0.13 0.200 240.0 327.3

HOGGING MOMENT = 15.42 1.07 0.318 381.0 206.1

SEGEMENT B :
SAGGING MOMENT = 5.46 0.38 0.200 240.0 327.3

HOGGING MOMENT = 2.40 0.17 0.200 240.0 327.3

IN BAND b-b :
SAGGING MOMENT = 9.63 0.67 0.200 240.0 327.3

HOGGING MOMENT = 17.13 1.19 0.356 427.0 183.9


Fck = 20 MPa Fy = 415 MPa
Beam : Slab load = 7.25 KN/sqm short span = 3.73 m
Span = 2.4 m B= 230 mm
slab load = 2.63 kN/m D= 450 mm
Self Weight = 2.5875 kN/m d= 415 mm
Wu = 7.83 kN/m say 8 kN/m
Clear cover to reinforcement = 25 mm
Mu =Wu * L2/10= 4.61 kN/m Vu = 9.60 kN
Mu/(B*d2)= 0.12 pt = 0.200 Ast = 190.90
Effective Depth Required = 85.20 mm
Diameter of bar = 20 mm
Providing 3 - 20 st @ top
3 - 20 st @ bottom Ast (pr)= 942.48
tv = 0.1006 N/sq.mm pt = 0.987
tc = 0.62 N/sq.mm b = 2.35
Vs = (tv - tc)*b*d -49.55
Spacing Sv= 0.87 fy Asv d / Vs = -303.99 mm
Provide #8 @ 200c/c
sqmm

sqmm
%
SUNSHADE DESIGN
GRADE OF CONCRETE = 20 Mpa
GRADE OF STEEL = 415 Mpa
BEARING OF LINTEL ON THE END SUPPORTS = 0.23 m
THICKNESS OF THE WALL = 0.23 m
HEIGHT OF THE BRICK WORK ABOVE THE LINTEL = 0.72 m
SUNSHADE WIDTH = 0.7 m

DESIGN OF SUNSHADE :
THICKNESS OF SUNSHADE D = 75 mm
EFFECTIVE DEPTH d = 56 mm
LOAD CALCULATIONS :
(1.) SELF WEIGHT = 1.3125 KN/m
(2.) LIVE LOAD = 0.8 KN/m
Wu = 3.17 KN/m SAY 3.2 KN/m
MAXIMUM BENDING MOMENT = W L /2 =
2
1.063 KNm
EFFECTIVE DEPTH REQUIRED = 19.623 mm
Mu/(B*d2)= 0.34 pt = 0.200 %
AST = 112.00 sqmm
DIAMETER OF BAR = 8 mm
SPACING OF BARS REQUIRED = 448.799 mm
SPACING OF BARS PROVIDED = 200 mm

CHECK FOR DEFLECTION :


AST PROVIDED = 251.327 sqmm
PERCENTAGE OF STEEL 0.449 %
STRESS IN STEEL AT SERVICE =0.58 Fy (As(R)/As(P)) = 107.264 MPa
MODIFICATION FACTOR (From Fig 4 IS 456-2000) 2.833
EFFECTIVE DEPTH REQUIRED = Lx/(7*M.F) 35.292 mm
DESIGN OF LINTEL OF < 1.5 m SPAN :
Fck = 20 MPa Fy = 415 MPa
LENGTH OF THE WINDOW OPENING = 1.5 m
BEARING OF LINTEL ON THE END SUPPORTS = 0.23 m
THICKNESS OF THE WALL = 0.23 m
HEIGHT OF THE BRICK WORK ABOVE THE LINTEL = 1.05 m
THICNESS OF SUNSHADE = 75 mm
WIDTH OF SUNSHADE = 0.7 m
LINTEL DIMENSIONS :
SPAN = 1.73 m Slab load = 7.25 KN./sqmm
WIDTH OF THE BEAM B = 0.23 m Long span = 4.545 m short span = 3.73 m
DEPTH OF THE BEAM D = 0.2 m Long span = 4.545 m short span = 3.945 m
EFFECTIVE DEPTH d = 0.174 m
LOAD CALCULATIONS :
SUNSHADE LOAD = 2.11 kN/m SLAB LOAD = wLx 3 - Lx 2
= 10.49 kN/m
SELF WEIGHT = 1.15 kN/m 6 Ly = 10.71 kN/m
WALL LOAD = 4.55 kN/m
SLAB LOAD = 21.19 kN/m TOTAL = 21.19 kN/m

Wu = 43.51 kN/m say 44 kN/m


CLEAR COVER TO REINFORCEMENT = 20 mm
Mu =Wu * L2/8= 16.46 kNm Vu = 38.06 kN
Mu/(B*d2)= 2.36 pt = 0.782 Ast = 313.11 sqmm
EFFECTIVE DEPTH REQUIRED = 161.03 mm
DIAMETER OF BAR = 12 mm
PROVIDING 2 - 12 st @ TOP
3 - 12 st @ BOTTOM Ast (pr)= 226.19 sqmm
tv = 0.9510 N/sq.mm pt = 0.565 %
tc = 0.50 N/sq.mm b = 4.11
Vs = (tv - tc)*b*d 17.96 KN.
SPACING Sv= 0.87 fy Asv d / Vs = 351.64 mm
PROVIDE #8 @ 200c/c
CHECK FOR DEFLECTION :
AST PROVIDED AT MID SPAN = 226.19 sqmm
PERCENTAGE OF STEEL 0.565 %
STRESS IN STEEL AT SERVICE =0.58 Fy (As(R)/As(P)) = 333.19 MPa
MODIFICATION FACTOR (From Fig 4 IS 456-2000) 0.875 O.K.
EFFECTIVE DEPTH REQUIRED = Lx/(20*M.F) 98.87 mm O.K.
DESIGN OF LINTEL OF < 2.0 m SPAN :
Fck = 20 MPa Fy = 415 MPa
LENGTH OF THE WINDOW OPENING = 2 m
BEARING OF LINTEL ON THE END SUPPORTS = 0.23 m
THICKNESS OF THE WALL = 0.23 m
HEIGHT OF THE BRICK WORK ABOVE THE LINTEL = 1.05 m
THICNESS OF SUNSHADE = 75 mm
WIDTH OF SUNSHADE = 0.7 m
LINTEL DIMENSIONS :
SPAN = 2.23 m Slab load = 7.25 KN./sqmm
WIDTH OF THE BEAM B = 0.23 m Long span = 6.705 m short span = 3.73 m
DEPTH OF THE BEAM D = 0.23 m Long span = 7.245 m short span = 2.4 m
EFFECTIVE DEPTH d = 0.204 m
LOAD CALCULATIONS : SLAB LOAD ON SHORT SPAN= wLx = 9.01 kN/m
SUNSHADE LOAD = 0.00 kN/m 3
SELF WEIGHT = 1.32 kN/m SLAB LOAD ON LONG SPAN= wLx 3 - Lx 2
= 8.38 kN/m
WALL LOAD = 4.55 kN/m 6 Ly
SLAB LOAD = 17.40 kN/m TOTAL = 17.40 kN/m

Wu = 34.91 kN/m say 35 kN/m


CLEAR COVER TO REINFORCEMENT = 20 mm
Mu =Wu * L2/8= 21.76 kNm Vu = 39.03 kN
Mu/(B*d2)= 2.27 pt = 0.745 Ast = 349.76 sqmm
EFFECTIVE DEPTH REQUIRED = 185.13 mm
DIAMETER OF BAR = 12 mm
PROVIDING 2 - 12 st @ TOP
3 - 12 st @ BOTTOM Ast (pr)= 226.19 sqmm
tv = 0.8317 N/sq.mm pt = 0.482 %
tc = 0.47 N/sq.mm b = 4.82
Vs = (tv - tc)*b*d 16.90 KN.
SPACING Sv= 0.87 fy Asv d / Vs = 438.15 mm
PROVIDE #8 @ 200c/c
CHECK FOR DEFLECTION :
AST PROVIDED AT MID SPAN = 226.19 sqmm
PERCENTAGE OF STEEL 0.482 %
STRESS IN STEEL AT SERVICE =0.58 Fy (As(R)/As(P)) = 372.18 MPa
MODIFICATION FACTOR (From Fig 4 IS 456-2000) 0.816 O.K.
EFFECTIVE DEPTH REQUIRED = Lx/(20*M.F) 136.63 mm O.K.