You are on page 1of 3

Himu Academy

01722535677
EEE Job Preparation +BUET Admission Coaching

SL Subject Topics
DC Circuit*** Total equivalent circuit Resistance (Series- parallel), Source
Conversion, Nodal and Super Nodal Analysis, Star-Delta and Delta-
star, Norton, Thevenin, Superposition, Max. Power Transform.
1 Electrical Circuit AC Circuit R-C. R-L, R-L-C Circuit, Frequency response, polar, rectangular
(10) form, frequency resonance curve, Thevenin theorem, Max. Power
Transform.
Op-Amp*** Pin configuration, symbol an ideal op-amp and op-amp and
characteristics, Inverting, Non inverting, Summing, Differential,
Integrator, difference amplifier, ( all math).
Filter All types of filter (HPF, LPF, BPF, All Pass Filter) with curve,
describe and math derivative 1st, 2nd, 3rd 4rd LPF, BPF, All Pass
Filter and HPF.
DLD*** All logic gate symbol, SOP and POS, truth table and Ckt diagram,
2 Electronics Boolean Algebra and Function, A/D and D/A Circuit. Multiplexing,
Adder (Half and full with ckt.), Karno Map, flip-flop ckt.
Transistor and
Transistor
Biasing
All types of Math Normal Diode, Ziner Diode, Clipper Circuit, Clamper Ckt etc.
Diode*** (All math and characteristics curve )
BJT, FET and MOSFET (All Math)***
Power and Energy Signal with math, Odd and Even Signal with math, Ram Signal with
3 Signal and math, Discrete, Continuous, Difference between analog and digital signal, Rectangular
Systems*** pulse, Ramp function, Sampling Function, Sinc function, Unit step function, Unit
impulse function, Linear and Non-linear System with math, time Varying and Non
Variant system, Convolution Integral with math, Periodic and Aperiodic signal with
math.
Importance of Control System, Open Loop and Close Loop System(Definition, Block
4 Control System Diagram, Configure, Advantage and Disadvantage), Input-Output relationship Open and
Engineering*** Close Loop System, Transfer function (TF), Circuit convert into block diagram using TF,
Signal Flow Graph with math, Properties of SFG, Mansons Rule, Loac Routs etc.
Modulation & Demodulation theory and all math*** (Chapter V.K Mehta BOOK),
5 Communications Nyquist sampling theorem and math, BER, OSI Model, ASK, PSK, FSK, QAM, QPSK,
NRZ, ADM, DM, difference between ADM and DM, PCM.

***Chapter : 08 ***Math: (8.1-8.18, 8.20, 8.21, 8.22, 8.23, 8.31, 8.32, 8.33, 8.38,
Transformer 8.40, 8.41, 8.42, 8.48, (8.56-8.67***), 8.68, 8.69, 8.70, 8.72, 8.93-
(V.K Mehta) 8.95, ), Transformer Equivalent circuit, Transformer test (open
circuit or no load and short circuit or impedance test), Advantage
Electrical Machine and Disadvantage of Transformer test, Why transformer rating in
6
kVA, Losses in Transformer, All day efficiency, Describe Auto
Transformer and their advantage and disadvantage, Condition of

Himu Academy, Rana Nirob, B.sc Engg. in EEE (PU), PGD in ICT (BUET), M.sc Engg. in ICT (BUP),
M.sc Engg. in Telecom (UITS), Contact: +8801722-535677, E-mail:smhimuacademy19sept@gmail.com
parallel operation, three phase Transformer connections, Describes
CT and PT with ckt diagram, Describe Instrument transformer and
their advantage.
***Induction
Motor
(B.L Theraja)
***Chapter : 08 Working principle, Equivalent Circuit, Applications, Pull out toque,
Synchronous Motor phasor diagram, V curve for Synchronous motor,
Motor Synchronous condenser, difference between synchronous and
(V.K Mehta) induction motor.
Math: 13.2, 13.4, 13.5, 13.6, 13.7, 13.9, 13.12, 13.13, 13.14, 13.15,
13.17, 13.18, 13.19, 13.20, 13.21.

Generator

Alternator
Principles of Power System Written by V.K Mehta, Rohit Mehta
Chapter: 02 Advantage and disadvantage of steam, hydroelectric, diesel and
Nuclear power station.
Chapter: 03*** Definition: Max. Demand, Demand factor, Average Load, Load
Factor, Diversity Factor, Plant Capacity Factor, Plant use factor,
base load and peak load.
Math:3.2-3.7, 3.10, 3.11
Chapter: Disadvantage of low power factor, causes of low power factor,
(PFI)06*** power factor improvement, Power factor improvement equipment
(describe Static capacitor, Synchronous condenser, Phase advancers
with Advantage & disadvantage).
Electrical Power System Math: (6.1-6.8), 6.13,6.14, 6.15
Chapter: 08 Corona, Affecting of corona, Advantage & disadvantage of corona
definition: Critical Disruptive voltage, Visual critical voltage, power
loss due to corona, Sag.
Math: (8.18-8.24)
Chapter: 10*** Determination of generalized constant for Transmission lines

Chapter: 12 Method of 3-Wire DC System (Only Ckt diagram), Difference


between Overhead and underground system, connection of
distribution system (Radial, Ring main, Interconnected system only
ckt diagram).
Chapter: 13*** Math: (13.1-13.4, 13.5-13.9, 13.10-13.12)****, Balancers in 3-wire
dc system only ckt diagram, describes Boosters with ckt diagram.

Chapter: 15*** Describes Off load tap-changing and On load tap-changing


transformer, Auto-transformer tap-changing, Booster Transformer
and Induction Regulators, How voltage control by synchronous
condenser.
Chapter: 17*** What is Symmetrical fault, Define Percentage Reactance, Why we
use Percentage Reactance? , Short Circuit kVA, What is Reactor?
Why we use reactor, write down advantage and disadvantage of

Himu Academy, Rana Nirob, B.sc Engg. in EEE (PU), PGD in ICT (BUET), M.sc Engg. in ICT (BUP), M.sc
Engg. in Telecom (UITS), Contact: +8801722-535677, E-mail:smhimuacademy19sept@gmail.com
reactor, describes generator reactors (ckt diagram, advantage and
disadvantage), Feeder reactors (ckt diagram, advantage and
disadvantage), Bus-bar reactors (ckt diagram, advantage and
disadvantage).
Math: (17.1-17.5, 17.12, 17.13, 17.14, 17.15)
Chapter: 18*** What is Unsymmetrical fault?, describes operator ‘a’,
Only Ckt Diagram:
Single line-to-ground fault, Line-to-line fault, Double line-to-ground
fault.
Chapter: 18*** Definition: Arc Phenomenon, Arc voltage, Restriking voltage,
Recovery voltage, Breaking capacity, Making capacity, Short-time
rating, Current chopping.
Definition, advantage and disadvantage: Oil Ckt Breakers, Air-Blast
Circuit Breakers, S Circuit breakers and Vacuum ckt breakers.
Chapter : Fuse, ad & disad. Of fuses, Definition: Fusing Current, Fusing
20(Fuses) factor, Prospective current, Cut-off current, Pre-arcing current, total-
operating time. Describes, advantage and disadvantage of High-
Rupturing Capacity Cartridge fuse (HRC) with figure. Write down
difference between Fuse and Ckt Breaker
Chapter : Draw a Circuit diagram Induction Type Directional Power Relay,
21(Protective Induction Type Directional Over current Relay, Time-distance
Relays) Impedance Relay.
Describe Current differential relay and voltage balance differential
relay.
Chapter : 22 Draw a Circuit diagram Differential Protection of Alternators,
Modified Differential Protection of Alternators and Star Inter-turn
Protection. Describes Buchholz Relay, Draw a Circuit diagram
Circulating-Current Scheme for Transformer Protection.
Power System (Hadi Saddat)
Single Line Diagram Math***

Himu Academy
Director
Rana Nirob
B.sc Engg. in EEE (PU)
PGD in ICT (BUET)
M.sc Engg. in ICT (BUP)
M.sc Engg. in Telecom (UITS)
Contact: +8801722-535677
E-mail:smhimuacademy19sept@gmail.com

You might also like