Sewage Treatment Plant ACO Aeropur Plus

Sizes 3 – 100
ACO Aeropur Plus

Characteristic, application Treatment process Advantages

The ACO Aeropur Plus sewage treatment plants • Mechanical pre-treatment • Easy installation as a compact and light-
are designed for the complete biological purifi- • Biological treatment by activated sludge weight unit
cation of domestic wastewater originating • Final gravity sedimentation • Very stable and high treatment efficiency
from: during irregular hydraulic and mass load –
• single-houses overload resistant
• residential areas • Effective purification also of total nitrates
• hotels (Ntot)
• boarding-houses • Low maintenance
• companies, etc. • Low energy consumption

The ACO Aeropur Plus sewage treat-


ment plants comply with all require-
ments of EN 12566-3.

Blower
Air

Sludge water

Return sludge Surplus sludge

Inlet

Outlet
1

2 4
5
3

Key:
1. Primary treatment – aerated screen basket
2. Buffer tank
3. Activation
4. Final sedimentation
5. Suplus sludge storage tank
ACO Aeropur Plus

Technology description

The ACO Aeropur Plus technological line con- Biological part of the ACO Aeropur Plus con- Surplus sludge is stored separately in the sto-
sists of mechanical and biological parts. sists of the activation tank (3) and the built-in rage tank (5) which is capable of holding it for
final sedimentation tank (4). 100 – 150 days. Thanks to the separate stora-
Mechanical part of the ACO Aeropur Plus is ge tank surplus sludge does not affect purifica-
composed of the aerated screen basket (1) Activation tank is aerated intermittently by tion efficiency of the ACO Aeropur Plus in any
being submerged into the buffer tank (2). micro-bubble aeration. Intermittent operation way.
provides electric power saving up to 50 per-
Sludge water is supplied into the ACO Aeropur cent, and simultaneously even better purifica- Pumping of sludge water, return sludge and
Plus through the inlet pipe whereby it flows into tion efficiency. In the mode of aeration (nitrifica- surplus sludge is carried out with the aid of air-
a screen basket. Coarse-grained matters are tion) there occur degradation of organic pollu- lift pumps in the ACO Aeropur Plus. These
entrapped into the screen basket and pre-trea- tion and ammonia. In the mode of aeration pumps need no maintenance and they are ent-
ted water passes freely through the basket break (denitrification) there is a reduction of irely resistant to clogging. Hydraulic capacity
screening meshes into the buffer tank space. value of nitrogen total volume. of the pumps is continuously adjustable even
Screen basket is aerated intensively from with a very small flow of rate, which helps to
below. Air flowing through the screen basket From the activation tank the water flows into ensure uniform process of purification and thus
grinds/crushes a part of coarse-grained impuri- the final sedimentation tank. Then gravitational stable purification efficiency.
ties (left-overs, paper, etc.) which leaves the separation of treated water from activated slud-
screen basket in the form of small particles ge is realized there. Treated water flows off the As the only electric appliance of the ACO
together with pre-treated water. This “self-clea- sewage treatment plant through an outlet unit. Aeropur Plus there is a blower supplying air
ning effect” of the screen basket extends con- Activated sludge falls down to the bottom of into aeration elements in the activation tank
siderably time period of its filling and even the final sedimentation tank from where it is and into air-lift pumps. Blower operation is
intervals of its emptying by the operating staff. pumped and then returns sludge back to the time-controlled. Blower intermittent operation
activation tank and partly into the storage tank guarantees electric power savings up to 50
Hydraulic peaks at the inlet of the ACO Aeropur (5) as surplus sludge. percent.
Plus sewage treatment plants are eliminated
with the aid of the buffer tank from where pre- Final sedimentation tank is equipped with a
treated water is pumped uniformly into the device for automatic collection and removal of
plant biological part. Hydraulic peak equalizing floating sludge from water level. This device
supports stable purification efficiency consider- supports markedly reduction of maintenance
ably. works during operation.

Outlet Unit 3
Blower

Automatic Removing
Ventilation
of Sludge from
Water Surface

Inlet

Final Sedimentation

Buffer Tank

Activation Tank
Aerated
Screen Basket
Microbubble aeration

Air-lift Pump

Surplus Sludge
Storage Tank
ACO Aeropur Plus

Sizing, hydraulic and biological capacity

ACO Aeropur Plus 3 5 12 22 35 50 70 100


Calculated values
of hydraulic and biological load
Hydraulic load [m3/day] 0.45 0.75 1.80 3.30 5.25 7.50 10.5 15.0
Biological load BOD5 [kg/day] 0.18 0.30 0.72 1.32 2.10 3.00 4.20 6.00

Range of usage
Number of PE 2–5 3–8 8 – 16 16 – 28 28 – 42 42 – 60 60 – 85 85 – 120
Hydraulic load [m3/day] 0.30 – 0.75 0.45 – 1.20 1.2 – 2.4 2.4 – 4.2 4.2 – 6.3 6.3 – 9.0 9.0 – 12.8 12.8 – 18.0
Biological load BOD5 [kg/day] 0.12 – 0.30 0.18 – 0.48 0.48 – 0.96 0.96 – 1.68 1.68 – 2.52 2.52 – 3.60 3.60 – 5.10 5.10 – 7.20

ACO Aeropur Plus 3 – 12 ACO Aeropur Plus 22 – 100


H4
H4
H1

H2

H1

H2
1 3

1 3
H

H
H3
H3

4 2

4 2
LxW
D

4
Inlet Outlet
Inlet 4 2 Outlet
DN150 DN150
DN150 DN150
(Ø160) 1 3 (Ø160)
(Ø160) 1 3 (Ø160)

4 2
Ventilation Ventilation
DN100 DN100
(Ø110) (Ø110)

Key:
1. Buffer tank
2. Activation tank
3. Final sedimentation tank
4. Surplus sludge storage tank
ACO Aeropur Plus

Technical data

ACO Aeropur Plus 3 5 12 22 35 50 70 100


Diameter D [mm] 1 330 1 470 2 030 - - - - -
Length L [mm] 3 000 4 000 5 000 6 160 8 660
Width W [mm] 2 160 2 160 2 160 2 400 2 400
Height H [mm] 2 200 2 550 2 950 3 020 3 020 3 020 3 020 3 020
Height of inlet pipe H1 [mm] 860 860 860 880 380 380 380 380
Height of outlet pipe H2 [mm] 980 980 980 1 000 500 500 500 500
Depth of water H3 [mm] 1 200 1 550 1 950 2 000 2 300 2 500 2 500 2 500
Height of ventilation pipe H4 [mm] 720 720 720 720 220 220 220 220
Weight [kg] 187 263 579 891 1 159 1 728 2 149 2 872
Power supply [V/Hz] 230/50 3x400/50
Article No. 405166 405167 405168 405169 405170 405171 405172 405173

Efficiency of purification

The following average values of effluent were


achieved during tests in an accredited laborato-
ry according to EN 12566-3:

BOD5 .................................................9.2 mg/l


COD.................................................60.0 mg/l
TSS ..................................................17.6 mg/l
N-NH4 ................................................2.6 mg/l
Ntot.................................................34.4 mg/l

5
ACO Aeropur Plus

Adapters of ACO Aeropur Plus

Main tanks of the ACO Aeropur Plus are stati- To make utilization of the above mentioned If some adapters are used there, the sewage
cally designed for in ground installation without option possible without any expensive con- treatment plant cover remains the same as
concrete encasement up to inlet pipeline depth struction work, the ACO Aeropur Plus main though it were used for the main tank only.
of 1.35 m. This option offers greater flexibility tanks are provided with adapters which means
during installation of the ACO Aeropur Plus and it is possible to heighten the main tank of the
better adaptation to local conditions (installa- ACO Aeropur Plus quick and easily.
tion of inlet and outlet pipeline in ice-free depth,
guarantee sufficient slope of the inlet and out-
let pipeline, etc.).

Adapters of ACO Aeropur Plus 3 – 12

Adapters are of circular ground plans and it is


possible to place them fluently into the main
tank of the ACO Aeropur Plus to any position,
in a range according to the adapter type.
Adapter position is locked by screws. Fluent
height adjustment from 60 to 500 mm allows
either application of two adapters of different
heights individually or both adapters may be fit-
ted together.

6 ACO Aeropur Plus 3 5 12


320 - 500

Height H [mm] 60 – 140


A Weight [kg] 11 13 16
140 - 320

Article No. 405174 405175 405176


60 - 140

Height H [mm] 140 – 320


B Weight [kg] 19 23 28
Article No. 405192 405193 405194

A B A+B
ACO Aeropur Plus

Adapters of ACO Aeropur Plus 22 – 100


Ground plan dimensions of adapters are consi-
stent with the ACO Aeropur Plus main tank
dimensions. The selected adapter is put on the
main tank and locked by screws. That way it is
possible to raise the main tank height by
500 mm or 1,000 mm, according to the
adapter type. However if the customer
wish it is possible to supply even adapters
being manufactured to order, with their
heights ranging from 200 to 1,000 mm.

ACO Aeropur Plus 22 35 50 70 100


Height H [m] 500
Weight [kg] 135 161 185 263 340
Article No. 405177 405179 405181 405183 405185
Height H [m] 1 000
Weight [kg] 240 287 334 466 601
Article No. 405178 405180 405182 405184 405186

7
Subject to technical changes without notice

ACO Industries k.s.


582 22 Přibyslav
Havlíčkova 260
Tel.: +420 569 491 111
1252/IC Aeropur/En/05/06/JL

Fax: +420 569 482 529


www.aco.cz
e-mail: aco@aco.cz
Czech republic

© ACO Industries k.s. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guar-
antee since the conditions of use are beyond the control of the Company. It is the customer’s responsibility to ensure that each product is fit for its intended purpose and that the actual condi-
tions of use are suitable. This brochure and any advice is provided ACO Industries k.s. (the company) free of charge and accordingly on terms that no liability (including liability for negligence) will
attach the Companyor its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon
its standard conditions of sale, copies of which are available on request. The Company’s policy of continuous product development and improvement renders specifications liable to modification.
information provided in this brochure is therefore subject to change without prior notification.

You might also like