PHASE FAILURE RELAYS

These relays are suitable for monitoring incoming


3-phase supply from Mains (Electricity distribution
line). Being independent of load, they can be used
for any HP/KW rating of load.
MODELS
VSP D1, VSP D2, VPG D1
P1 PFS2,
S2 VMR1, S2 VMR2, S2 VMR3, S2 VMR6
D1 HLS1, HLV D2, ALV D2, VMR D2, VST D1,
D1 VMR1, D2 VMR1, D2 VMR2,
S1 VMR7

FEATURES PROTECTIONS / FUNCTIONS


• Fixed/adjustable unbalance settings • Phase Failure (Phase Loss / Single
• Fixed/adjustable under- Phasing),
voltage/over-voltage settings
• Phase sequence reversal,
• Fixed/adjustable trip delays
• Voltage Unbalance,
• Built-in or external power supply
• Resetting Auto or Manual • Under Voltage,
• Output contacts : 1 CO or 2 CO • Over Voltage
• Choice of enclosures (DIN-Rail,
Plug-in)
• Models with Micro-Controller based
design
• Use of SMD Technology
• User-friendly LED indications Ordering Instructions
ü Product Family Name
ü Model Name
ü System Supply Voltage
& Frequency
ü Aux. Supply / Control
supply voltage
09
P H A S E F A I L U R E R E L A Y S
VSP D1 VSP D2 S1 VMR7
Phase Failure Relay Phase Failure Relay Phase Sequence Relay

Phase Failure, Unbalance, Phase Failure, Unbalance, Phase Sequence,


Phase Sequence, Phase Sequence, Auto Reset,
Auto Reset, Fixed Unbalance Auto / Manual / Remote Reset, 1 CO output relay
Setting, Adjustable Unbalance setting,
1 CO output Relay 2 CO output relay

Supply Voltage 100-120/220-240/380-440 V AC ±20% 50 / 60 Hz 100-120/220-240/380-440 V AC ±20% 50 / 60 Hz 380 – 440 VAC, ± 20%, 3PH-3 Wire
System
Auxiliary 100-120/220-240/380-440 V AC ±20% 100-120/220-240/380-440V AC ±20% Built-in from 3-Phase
Output Contacts 1 CO 2 CO 1 CO
Trip Setting (Volts)
Phase Sequence Yes Yes Yes
Phase Unbalance 40 V ±6 V (fixed) 30 V to 70 V ±6 V (adjustable) -

Trip Time Delay


On Phase Failure/Unbalance 3.5 sec. ±1.5 sec. 3.5 sec. ±1.5 sec. Instant
For level sensing N.A. N.A. N.A.
Resetting Mode Auto Auto / Manual / Remote Auto Reset
Weight 320 gms. 400 gms. 90 gms. (Approx.)
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 76 x 56.5 x 117.5 90 x 18 x 60 (Approx.)
Mounting (L x W) 68 centre to centre / 35 mm rail Mounting 67 x 46 / 35 mm rail Mounting 35 mm rail Mounting

• Wherever not specified


Contact Rating : Aux
5A @ 230 V AC Aux
Supply
Supply
(resistive) RYB R B Y R B R Y B
RYB R B Y R B R Y B
• * Available on request. Phase Fail
RYB R B Y R Y B
Phase Fail 3 Ph
3 Ph 3 Ph
17

14

Td : 2-5 Sec. Td : 2-5 Sec.


16

13

13 14
7 8
18

15

13 15
1 8
16

13

R
L1
R
L1
M
Y

B
L2
L3 M Y

B
L2
L3 M
OFF OFF

ON ON
N/V N/V
DOL STARTER DOL STARTER

1 2 3 4 5 6
1 2 3 VSP D2
VSP D1

AUX.
AUX. SUPPLY
SUPPLY
7 8 9 7 8 9 10 11 12

13 14 15 13 14 15 16 17 18

Relay contact position shown in 'Power off' condition

10
P H A S E F A I L U R E R E L A Y S

VPG D1 P1 PFS2 S2 VMR1


Phase Failure Relay Phase Failure Relay

C US

Single phasing, reverse phasing, Phase Failure, Unbalance, Microcontroller design,


unbalanced supply, Auto reset, Phase Sequence, SMD Technology,
1 CO output contact Auto Reset, fixed unbalance Phase Failure, Unbalance,
Suitable for any HP/kW rating setting, Phase Sequence
submersible pumps 1 CO output relay Auto/Manual Reset,
Low water level guard for dry Adjustable Unbalance setting,
running protection 2 CO output relay

415VAC ± 20%, 50 Hz ± 3% 110 / 240 / 380 / 415 V AC ±10%, 50 / 60 Hz 100-120 / 220-240 / 380-440V AC, -25+20%, 48-63 Hz

Built-in Built-in Built In


1 CO 1 CO 2 CO

Yes Yes Yes


40 V ±6 V 40V ± 6V (fixed) 4 % TO 20 % (Variable) ± 5% of full scale.

3.5 Sec ± 1.5 Sec 3.5 sec. ±1.5 sec. 4 Sec ± 1 Sec / RP-Instant
3.5 Sec ± 1.5 Sec N.A. N.A.
Auto Reset Auto Auto/ Manual Reset (Selectable by Front Push Button)
300 gms. 175 gms. 100 gms (Approx.)

76 x 30.5 x 117.5 50 x40 x 80 90 X 35 X 60


68 centre to centre / Panel Mounting & 8 - Pin Plug-in 35 mm Rail Mounting
35 mm rail Mounting

RYB R B Y R B R Y B RYB R B Y R B R Y B
RYB R Y R B Y
Phase Fail
3 Ph /Reverse
3 Ph
Water Level Td : 3-5 Sec.

Td : 2-5 Sec. Unbalance


8 11 >4 - 20 %
1 3 7 10

7 9 10 12
1 4

L1 R
R
R
Y
B
L2
L3 M Y

B
M Y
B
M
N/V

OFF

ON
4 5
3 6
1 2 3
VPG D1
2 7
PROD 1 8
7 8 9

Bottom view
13 14 15
WATER TANK

Relay contact position shown in 'Power off' condition

11
P H A S E F A I L U R E R E L A Y S
S2 VMR2 HLV D2 ALV D2
Phase Failure Relay Phase Failure with UV / OV Relay Phase Failure with UV / OV Relay

C US

Microcontroller design, Phase Failure, Unbalance, Phase Failure, Unbalance,


SMD Technology, Phase Sequence, under voltage, Phase Sequence, under voltage,
Phase Failure, Unbalance, Over Voltage, Manual reset, Over Voltage Auto Reset,
Phase Sequence, under voltage, Fixed Unbalance setting, Fixed Unbalance setting,
Over Voltage, Auto reset,
Adjustable UV/OV settings, Adjustable UV/OV settings,
Fixed Unbalance setting,
2 CO output relay 2 CO output relay
Fixed UV/OV settings,
2 CO output relay

Supply Voltage 100-110-120 / 220-230-240 / 380-415-440V AC -25+20%,


System 48-63 Hz, Selectable by Front Knob 110 / 240 / 380 / 415 / 440 V AC ±20% 50 / 60 Hz 110 / 240 / 380 / 415 / 440 V AC ±20% 50 / 60 Hz
Auxiliary Built In (from 3 Phase) 110 V (Fixed) or (220 - 230 - 240) or (380 - 415 - 440) V AC ±20% selectable
Output Contacts 2 CO 2 CO 2 CO
Trip Setting (Volts)
Phase Sequence Yes Yes Yes
Phase Unbalance 10% (Fixed) ± 10% 40 V ±6 V (fixed) 40 V ±6 V (fixed)
Under For 380-440V AC 80% to 95% (adjustable) 80% to 95% (adjustable)
Voltage For 220-240V AC
For 100-120V AC
± 20% (Fixed)
Over For 380-440V AC 105% to 120% (adjustable) 105% to 120% (adjustable)
Voltage For 220-240V AC
For 100-120V AC
Trip Time Delay
On Phase Failure 2 - 5 Sec. (Fixed) / RP-Instant 3.5 secs. ± 1.5 sec 3.5 secs. ± 1.5 sec
On UV/OV Less than 2 secs. for OV & 2 - 5 secs for UV Less than 2 secs.
Resetting Mode Auto Reset Manual / Remote Auto Reset
Weight 100 gms (Approx.) 430 gms. 400 gms.
Dimensions (mm)
Overall (L x W x D) 90 X 35 X 60 76 x 56.5 x 117.5 76x 56.5 x 117.5
Mounting (L x W) 35 mm Rail Mounting 67 x 46 / 35 mm rail Mounting 67 x 46 / 35 mm rail Mounting

• Wherever not specified OV OV


OV
Contact Rating : RYB RY R B Y
Aux
UV
Aux
UV
Unbalance /
5A @ 230 V AC 3 Ph Phase fail
UV
Supply Supply
RYB R B RBY RYB RYB R B RBY RYB
(resistive) Td : 2-5 Sec.
Td : 2-5 Sec.
3 Ph Unbal./
3 Ph Unbal./

• * CE marked products 7 8 10 11
Phase Fail
Td : 2-5 Sec.
Phase Fail
Td : 2-5 Sec.
available on request. 13 14 16 17 13 14 16 17

7 9 10 12 13 15 16 18 13 15 16 18

S2 VMR6 R
Y M R
L1
R
L1

B Y
L2
MOTOR Y
L2
MOTOR
L3 L3
B B

OFF OFF ON
ON N/V
N/V
DOL STARTER
DOL STARTER

1 2 3 4 5 6
1 2 3 4 5 6 ALV D2
HLV D2
AUX.
AUX. SUPPLY
SUPPLY
7 8 9 10 11 12
7 8 9 10 11 12
Microcontroller design, SMD
Technology, Phase Failure, 13 14 1516 17 18
13 14 1516 17 18

Unbalance, Phase Sequence,


Under Voltage, Over Voltage,
Neutral Failure, Auto Reset,
Adjustable OV/UV settings,
2 CO output relay. Relay contact position shown in ‘Power off' condition
System supply voltage
415 V AC

12
P H A S E F A I L U R E R E L A Y S
VMR D2 D1 HL S1 VST D1 D1 VMR1
Phase Failure with UV / OV Relay Phase Failure with UV / OV Relay Phase Failure with Under Voltage Phase Failure with UV / OV Relay

Phase Failure, Unbalance, Phase Failure, Unbalance, Phase Failure, Phase Sequence, Phase Failure, Unbalance,
Phase Sequence, under voltage, Phase Sequence, under voltage, Auto Reset, Phase sequence, Under & Over
Over Voltage, Auto Reset, under voltage, Over Voltage, Adjustable trip delay, voltage, Auto Reset,
Fixed Unbalance setting, Auto reset, Fixed Unbalance Adjustable UV setting, fixed unbalance setting,
Adjustable UV/OV settings, setting, Fixed UV/OV settings, 1 CO output relay Adjustable UV/OV settings,
2 CO output relay 2 CO output relay Selectable range of supply fixed trip delay,
voltage 2 CO output relay

110/220/230/240/380/415/440 V AC ±20% 100-110-120/220-230-240/380-415-440V AC+20,-25%,


50/60 Hz 48-63 Hz, Selectable by Front Knob 240 / 415 / 575 V AC 3 Phase (±15% selectable) 100-120/220-240/380-440 VAC±20%, 3Ph-3Wire
Built-in Built-in Built-in
2 CO 2 CO 1 CO 2 CO

Yes Yes Yes Yes


94 V ±6 V (fixed) 10% (Fixed) N.A. 10% (fixed)
80% to 95% (adjustable) 75% of system supply (Fixed) 80% of V set 285-425V AC [Variable]
165-225V AC [Variable]
75-115V AC [Variable]
105% to 120% (adjustable) 120% of system supply (Fixed) N.A. 400-520V AC [Variable]
230-290V AC [Variable]
105-140V AC [Variable]

3.5 secs. ± 1.5 sec 3.5±1.5 secs. [Fixed] 0.2 - 10 secs. (variable) 3.5 secs ± 1.5 sec.
Less than 2 secs. Less than 2 secs. 0.2 - 10 secs. (same for UV & SP) 3.5 secs ± 1.5 sec.
Auto Reset Auto Auto Auto
400 gms. 200 gms. 300 gms. 430 gms.

76x 56.5 x 117.5 76 x 30.5 x 117.5 76 x 30.5 x 117.5 76 x 30.5 x 117.5


67 x 46 / 35 mm rail Mounting 68 centre to centre / 35 mm rail Mounting 68 centre to centre / 35 mm rail Mounting 68 centre to centre / 35 mm rail Mounting

RYB RY R B Y
OV OV RYB RY R B Y OV
UV UV Phase fail UV
Aux Aux 3 Ph Unbalance / UV
Supply Supply 3 Ph Phase fail
Td :0.2-10 Sec.
RYB R B RBY RYB RYB R B RBY RYB Td : 3.5 Sec.

3 Ph Unbal./
Phase Fail
3 Ph Unbal./
Phase Fail 13 14 13 14 1 2
Td : 2-5 Sec. Td : 2-5 Sec.
13 14 16 17 13 14

13 15 16 18 13 15 13 15 13 15 1 3

L1
R
L L
L1 L2
O O
R
L2 A
Y MOTOR A
L3
Y
L3
MOTOR D
B
D

OFF
OFF ON
ON N/V
N/V
DOL STARTER DOL STARTER
DOL STARTER
1 2 3
VST D1

1 2 3 4 5 6

VMR D2
D1 HLS1
AUX.
SUPPLY 7 8 9
7 8 9 10 11 12

13 14 1516 17 18 13 14 15

Relay contact position shown in 'Power off' condition

13
P H A S E F A I L U R E R E L A Y S
D2 VMR 1 D2 VMR 2 S2 VMR 3
Phase Failure with UV / OV (3Ø-3W) Phase Failure with UV / OV (3Ø-4W) Phase Failure with UV / OV Relay

R R R

C US C US C US

Suitable for 3 Ph-3W system, Suitable for 3 Ph-4W system, Microcontroller design,
Microcontroller design, Microcontroller design, SMD Technology,
Absolute values of UV/OV settings, Absolute values of UV/OV settings Absolute values of UV/OV settings,
Phase Failure, Unbalance, Phase Phase Failure, Unbalance, Phase Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage, Sequence, under voltage, Over Voltage Sequence, under voltage, Over Voltage
Auto/Manual reset, Adjustable settings Auto/Manual reset, Adjustable settings for Auto/Manual reset, Adjustable settings
for Unbalance, UV/OV and trip delays, Unbalance, UV/OV and trip delays, for Unbalance, UV/OV and trip delays,
2 CO output relay 2 CO output relay 2 CO output relay

Supply Voltage
System 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
Auxiliary Built In (from 3 Phases) Built In (from 3 Phases) Built In (from 3 Phases)
Output Contacts 2 CO 2 CO 2 CO
Trip Setting (Volts)
Phase Sequence YES YES YES
Phase Unbalance 4 % - 20 % [Variable] 4 % - 20 % [Variable] 4 % - 20 % [Variable]
Under For 380-440V AC 285-425V AC [Variable] 165-245V AC [Variable] 285-425V AC [Variable]
Voltage For 220-240V AC 165-225V AC [Variable] 95-135V AC [Variable] 165-225V AC [Variable]
For 100-120V AC 75-115V AC [Variable] 45-65V AC [Variable] 75-115V AC [Variable]

Over For 380-440V AC 400-520V AC [Variable] 230-310V AC [Variable] 400-520V AC [Variable]


Voltage For 220-240V AC 230-290V AC [Variable] 130-170V AC [Variable] 230-290V AC [Variable]
For 100-120V AC 105-145V AC [Variable] 60-80V AC [Variable] 105-145V AC [Variable]

Trip Time Delay


On Phase Sequence Instant Instant Instant
On SP/UV/OV 1 To 10 Sec [Variable) 1 To 10 Sec [Variable) 1 To 10 Sec [Variable)
Resetting Mode Auto/ Manual Reset (External NC Push Buttons) Auto/ External Manual Reset (External NC Push Buttons) Auto/ Manual Reset [Selectable]
Weight 300 gms. 300 gms. 110 gms (Approx.)
Dimensions (mm)
Overall (L x W x D) 76 X 56.5 X 117.5 76 X 56.5 X 117.5 90 X 35 X 60
Mounting (L x W) 67 x 46 / 35 mm rail Mounting 67 x 46 / 35 mm rail Mounting 35 mm Rail Mounting

• Wherever not specified RYB RY R B Y OV RYB RY R B Y OV

Contact Rating : RYB RY R B Y OV


Unbalance / UV Unbalance / UV
5A @ 230 V AC Unbalance / UV 3 Ph N Phase fail 3 Ph Phase fail
3 Ph Phase fail

(resistive) Td : 1-10 Sec.


Td : 1-10 Sec.
Td : 1-10 Sec.
Td : 1-10 Sec.
Td : 1-10 Sec.
Td : 1-10 Sec.
13 14 16 17 7 8 10 11
13 14 16 17

13 15 16 18 13 15 16 18 7 9 10 12

R R R
L
O
L Y
Y Y O B
A
A
B D B D
N

MANUAL MANUAL
RESET RESET
PB PB

D2 VMR 1 D2 VMR 2

Relay position shown in 'Power off' condition