Supply Voltage 100-120/220-240/380-440 V AC ±20% 50 / 60 Hz 100-120/220-240/380-440 V AC ±20% 50 / 60 Hz 380 – 440 VAC, ± 20%, 3PH-3 Wire
System
Auxiliary 100-120/220-240/380-440 V AC ±20% 100-120/220-240/380-440V AC ±20% Built-in from 3-Phase
Output Contacts 1 CO 2 CO 1 CO
Trip Setting (Volts)
Phase Sequence Yes Yes Yes
Phase Unbalance 40 V ±6 V (fixed) 30 V to 70 V ±6 V (adjustable) -
14
13
13 14
7 8
18
15
13 15
1 8
16
13
R
L1
R
L1
M
Y
B
L2
L3 M Y
B
L2
L3 M
OFF OFF
ON ON
N/V N/V
DOL STARTER DOL STARTER
1 2 3 4 5 6
1 2 3 VSP D2
VSP D1
AUX.
AUX. SUPPLY
SUPPLY
7 8 9 7 8 9 10 11 12
13 14 15 13 14 15 16 17 18
10
P H A S E F A I L U R E R E L A Y S
C US
415VAC ± 20%, 50 Hz ± 3% 110 / 240 / 380 / 415 V AC ±10%, 50 / 60 Hz 100-120 / 220-240 / 380-440V AC, -25+20%, 48-63 Hz
3.5 Sec ± 1.5 Sec 3.5 sec. ±1.5 sec. 4 Sec ± 1 Sec / RP-Instant
3.5 Sec ± 1.5 Sec N.A. N.A.
Auto Reset Auto Auto/ Manual Reset (Selectable by Front Push Button)
300 gms. 175 gms. 100 gms (Approx.)
RYB R B Y R B R Y B RYB R B Y R B R Y B
RYB R Y R B Y
Phase Fail
3 Ph /Reverse
3 Ph
Water Level Td : 3-5 Sec.
7 9 10 12
1 4
L1 R
R
R
Y
B
L2
L3 M Y
B
M Y
B
M
N/V
OFF
ON
4 5
3 6
1 2 3
VPG D1
2 7
PROD 1 8
7 8 9
Bottom view
13 14 15
WATER TANK
11
P H A S E F A I L U R E R E L A Y S
S2 VMR2 HLV D2 ALV D2
Phase Failure Relay Phase Failure with UV / OV Relay Phase Failure with UV / OV Relay
C US
• * CE marked products 7 8 10 11
Phase Fail
Td : 2-5 Sec.
Phase Fail
Td : 2-5 Sec.
available on request. 13 14 16 17 13 14 16 17
7 9 10 12 13 15 16 18 13 15 16 18
S2 VMR6 R
Y M R
L1
R
L1
B Y
L2
MOTOR Y
L2
MOTOR
L3 L3
B B
OFF OFF ON
ON N/V
N/V
DOL STARTER
DOL STARTER
1 2 3 4 5 6
1 2 3 4 5 6 ALV D2
HLV D2
AUX.
AUX. SUPPLY
SUPPLY
7 8 9 10 11 12
7 8 9 10 11 12
Microcontroller design, SMD
Technology, Phase Failure, 13 14 1516 17 18
13 14 1516 17 18
12
P H A S E F A I L U R E R E L A Y S
VMR D2 D1 HL S1 VST D1 D1 VMR1
Phase Failure with UV / OV Relay Phase Failure with UV / OV Relay Phase Failure with Under Voltage Phase Failure with UV / OV Relay
Phase Failure, Unbalance, Phase Failure, Unbalance, Phase Failure, Phase Sequence, Phase Failure, Unbalance,
Phase Sequence, under voltage, Phase Sequence, under voltage, Auto Reset, Phase sequence, Under & Over
Over Voltage, Auto Reset, under voltage, Over Voltage, Adjustable trip delay, voltage, Auto Reset,
Fixed Unbalance setting, Auto reset, Fixed Unbalance Adjustable UV setting, fixed unbalance setting,
Adjustable UV/OV settings, setting, Fixed UV/OV settings, 1 CO output relay Adjustable UV/OV settings,
2 CO output relay 2 CO output relay Selectable range of supply fixed trip delay,
voltage 2 CO output relay
3.5 secs. ± 1.5 sec 3.5±1.5 secs. [Fixed] 0.2 - 10 secs. (variable) 3.5 secs ± 1.5 sec.
Less than 2 secs. Less than 2 secs. 0.2 - 10 secs. (same for UV & SP) 3.5 secs ± 1.5 sec.
Auto Reset Auto Auto Auto
400 gms. 200 gms. 300 gms. 430 gms.
RYB RY R B Y
OV OV RYB RY R B Y OV
UV UV Phase fail UV
Aux Aux 3 Ph Unbalance / UV
Supply Supply 3 Ph Phase fail
Td :0.2-10 Sec.
RYB R B RBY RYB RYB R B RBY RYB Td : 3.5 Sec.
3 Ph Unbal./
Phase Fail
3 Ph Unbal./
Phase Fail 13 14 13 14 1 2
Td : 2-5 Sec. Td : 2-5 Sec.
13 14 16 17 13 14
13 15 16 18 13 15 13 15 13 15 1 3
L1
R
L L
L1 L2
O O
R
L2 A
Y MOTOR A
L3
Y
L3
MOTOR D
B
D
OFF
OFF ON
ON N/V
N/V
DOL STARTER DOL STARTER
DOL STARTER
1 2 3
VST D1
1 2 3 4 5 6
VMR D2
D1 HLS1
AUX.
SUPPLY 7 8 9
7 8 9 10 11 12
13 14 1516 17 18 13 14 15
13
P H A S E F A I L U R E R E L A Y S
D2 VMR 1 D2 VMR 2 S2 VMR 3
Phase Failure with UV / OV (3Ø-3W) Phase Failure with UV / OV (3Ø-4W) Phase Failure with UV / OV Relay
R R R
C US C US C US
Suitable for 3 Ph-3W system, Suitable for 3 Ph-4W system, Microcontroller design,
Microcontroller design, Microcontroller design, SMD Technology,
Absolute values of UV/OV settings, Absolute values of UV/OV settings Absolute values of UV/OV settings,
Phase Failure, Unbalance, Phase Phase Failure, Unbalance, Phase Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage, Sequence, under voltage, Over Voltage Sequence, under voltage, Over Voltage
Auto/Manual reset, Adjustable settings Auto/Manual reset, Adjustable settings for Auto/Manual reset, Adjustable settings
for Unbalance, UV/OV and trip delays, Unbalance, UV/OV and trip delays, for Unbalance, UV/OV and trip delays,
2 CO output relay 2 CO output relay 2 CO output relay
Supply Voltage
System 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
Auxiliary Built In (from 3 Phases) Built In (from 3 Phases) Built In (from 3 Phases)
Output Contacts 2 CO 2 CO 2 CO
Trip Setting (Volts)
Phase Sequence YES YES YES
Phase Unbalance 4 % - 20 % [Variable] 4 % - 20 % [Variable] 4 % - 20 % [Variable]
Under For 380-440V AC 285-425V AC [Variable] 165-245V AC [Variable] 285-425V AC [Variable]
Voltage For 220-240V AC 165-225V AC [Variable] 95-135V AC [Variable] 165-225V AC [Variable]
For 100-120V AC 75-115V AC [Variable] 45-65V AC [Variable] 75-115V AC [Variable]
13 15 16 18 13 15 16 18 7 9 10 12
R R R
L
O
L Y
Y Y O B
A
A
B D B D
N
MANUAL MANUAL
RESET RESET
PB PB
D2 VMR 1 D2 VMR 2
14