You are on page 1of 7
QRO TESTLA Elektrik Laboratuvarlari Tic. Ltd. Sti. Kuzuluk Mah. Ankara Cad. No:34 ‘Akyazi ! SAKARYA / TURKIYE A8-0386-7 Tel:+90 264 437 97 70 Faks:+90 264 437 97 80 TEST REPORT www testia.com.tr a 1812.20.01100 28.12.2015 Hu Sigma Elektrik San. ve Tic. AS. Client Name/Address. | Yunus Emre Mh. Yenidogan Yolu Cd. No:30/A 34792 Sancaktepe/ ISTANBUL/ TURKIYE T: +90 216 429 72 01 F: +90 484 4101 Name And Identity Of Bodne $20 / Low voltage current transformers, Rated Characteristics | . . Gen By The Ghent 0:72KV- SOIGOHz- 150/5A- 10VA- 0,Scl- | Order No. 1512.20 | Sample Acceptance Date (> amalbinl Test Date(s) “| 14,12.2015-18.12.2015 TS EN 60947-4-1: 13.12.2011 Test Standard(s) Low-Voltage Switchgear and Control gear ~- Part 4-1: Contactors and Motor-Starters - Electromechanical Contactor Test Result(s) Details, are given on the following pages which are part ofthis report. Remarks ‘The test results relate only to the itoms tested. ‘Tests marked (#) in this test report are not included in the TURKAK accreditation schedule for this laboratory. TESTLA Elektrik Laboratuvarian accredited by TURKAK under registration number AB-0386-T for TS EN ISO/TS EN 17025:2012 as test laboratory. Turkish Accreditation Agency (TURKAK) is a signatory to the European co-operation for Accreditation (EA) Multilateral Agreement (MLA) and to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MIRA) for the recognition of test reports. ‘The test andlor moasuromont results, the uncertainties (if applicable) with confidence probability and test methods are given on the following pages which are part of this report. Person in Charge 28.12.2015 2010+ | Mehmet SUMNU Nihat GESMECi [33 TESTLA Elektrik Laboratuvarlari Tic. Ltd. Sti. Page:2/7 Contents : 1. Test of attendees 2. Applied Experiments 3. Short Circuit Withstand Test 3.1. Experiment laboratory 3.2. Standards 3.3. Experiment on mechanism 3.4. Product features 4. Types of experiments 4.1. The result of the experiment 4.2. The Evaluation of the Experiment 4.3. Images of test samples 1. Witnesses By : :Reyhan USTA SIGMA 2. Applied Tests : Short-time current tests 7.1 Temperature-tise test 7.2 Lightning impulse test 7.3.2 Accuracy class test. 11.1.1 3.Short Circuit Withstand Test 3.1. Experiment laboratory Experiments in a laboratory environment met the conditions of the standards. 3.2. Standards 3.3. Experiment on mechanism |] POWER TRANSFORMER ] CIRCUIT BREAKER TEST ‘SAMPLE 386. 28.12.2015 TELFRTSTREVOO s-00867 [Sj +e12200109 TESTLA Elektrik Laboratuvarlari Tic. Ltd. Sti. 29.12.2018 Page:3/7 - 3.4. Product features Product : Current transformer Type 2820 Manufacturer = SIGMA. Rated Operating Voltage ( Ue) 1 0,72kV Declared Conversion Rate (Kn) + 100/5A-125/5A-150/5A Declared a short-time current (ith) = (In x 100) Rated insulation level 3kV Rated Frequency 50-60Hz cL 05 Power 1100-125 / SVA , 150/ 10VA ‘4. Types of experiments 7.1Short-time current tests #37,5kA Peak / 15kA Effective Current Adjustment Phase Peak( Ipk Effective (I) Test voltage Cosa kA, v oi 2 37,8211 15,346 430V 03 B * Test 1: 150/5A-37,5kA Peak / 15kA effective current test (1sec.) Test | Phase Effective (I) Time Test voltage number kA msec. v ir 1 @ 37,754] 16,322 1010 430V B 7.3.2 Lightning impulse test Type Test Primary - Secondary | Primary Body | Primary -Frame Voltage Jak Lag S20 150/54 3KV Ok ok oK £4 _ “a § 3 2, eo 8 2010+ TELFR.18/REVOO

You might also like