You are on page 1of 2

Page 1 of 2

Caterpillar Electronic Technician 2011A v1.0


Configuration

2/20/2017 12:25 PM

C32 Genset (PRH01442)


Parameter Value
Equipment ID NOT PROGRAMMED
Engine Serial Number PRH01442
ECM Serial Number 07716118JV
Software Group Part Number 3459220-00
Software Group Release Date APR09
Software Group Description C32 MEUI ACERT A4

Description Value TT
ECM Identification Parameters
Equipment ID NOT PROGRAMMED 0
Engine Serial Number PRH01442 0
ECM Serial Number 07716118JV
Software Group Part Number 3459220-00
Software Group Release Date APR09
Software Group Description C32 MEUI ACERT A4
Selected Engine Rating
Rating Number 7 0
Rated Frequency 50 Hz
Rated Engine Speed 1500 rpm
Rated Real Genset Power Unavailable Parameter
Rated Apparent Genset Power 1100 kVA
Rating Configuration Low BSFC
Test Spec 0K89980K8994
Engine/Gear Parameters
Engine Acceleration Rate 500 rpm/s 0
Low Idle Speed 1200 rpm 0
Engine Speed Droop 3.0 % 0
Engine State Control Input Configuration CAN Input 0

file://D:\AP 2 CAT C32\Configuration 2-20-17 12.25 PM.XML 2/20/2017


Page 2 of 2

Remote Throttle Control Min Speed 125 rpm 0


Remote Throttle Control Max Speed 125 rpm 0
Cooldown Speed 1000 rpm 0
Cooldown Duration 3 min 0
Engine Pre-Lube Duration 0 sec 0
Crank Duration 30 sec 0
Maximum Number of Crank Cycles 5 0
Crank Terminate RPM 400 rpm 0
Droop Mode Selection Isochronous
I/O Configuration Parameters
Ether Control Disabled 0
Desired Speed Input Configuration PWM 1
Secondary Desired Speed Input Configuration CAN Input 1
Coolant Level Sensor Installed 1
Droop/Isochronous Switch Enable Disabled 0
Emergency Shutdown Override Switch Installation Status Not Installed 0
Emergency Shutdown Override Input Configuration Switch to Ground 0
Remote Emergency Stop (E-Stop) Switch Input Type Normally Closed (to
1
Configuration Ground)
Air Intake Shutoff Detection Installation Status Not Installed 0
Engine Oil Temperature Sensor Installation Status Installed 1
System Settings
Governor Gain Factor #1 5243
Governor Minimum Stability Factor #1 255
Governor Maximum Stability Factor #1 1020
FLS 65 0
FTS -79 0
Security Access Parameters
Total Tattletale 6

file://D:\AP 2 CAT C32\Configuration 2-20-17 12.25 PM.XML 2/20/2017