You are on page 1of 2

Easy Maintenance

The simple design concept has


maintenance and servicing in mind. NOMENCLATURE R407C MFS-15
Access to the internal parts of the unit
can be from front or back of the unit by
removing a few screws Easy and Flexible Installa on M F S 75 A
The easy is highly compact and therefore it is very easy to select
a loca on to install the unit such that only small space is FREE BLOW SPLIT AIR CONDITIONER

Filter Rack
required. Genera on
75-200
The fan coil unit has a filter rack to hold Capacity 75, 100, 125, 150
the air filter. This ensure the air flow is
clean and the filter is easily accessible Standing Fan Coil
for maintenance and cleaning
Floor
Mc Quay

Feature & Excellence R407C


• Designed to substitute R22
• Physical and thermodynamic properties comparable
to R22
Maximum Allowable Piping Length & Eleva on Difference • Zeotropic refrigerant blend containing R32, R125 &
R134a (23/25/52% by weight)
Casing
The unit is made of 0.8 to 2.3 mm galvanized steel body with • Temperature glide approximately 7K ( zeotropic
behavior)
polyester powder coat. It is insulated with 10 mm polyethylene
• Miscible with polyoester oils (POE)
foam. A perforated sheet cover protects the filter from damage.
• Environmentally acceptable (ODP = 0) 23 % R32 25 % R125 52 % R134A
• Able to retrofit existing R22 units
Electric Controller • Non-flammable and safe to use
Electric Controller can display cool, dry and fan mode with auto, high,
( R407C )
• Commercially available
medium and low fan speed. The temperature se ngs range from 16 O C
and 30 O C. There is a sleep func on for cool
mode and programmable on / off mer 1 hour interval. The controller SLM 3 Netware 3
( optional )
is built with 3 minutes restart delay mer for compressor protec on.

Head Office:
Bali. Pertokoan Gunung Soputan Blok B, Jl. Gunung Soputan No. 11, Denpasar 80117, Indonesia
Surabaya. Jl. Kayoon 42-44, Surabaya 60271, Indonesia | P. +62-31-547 8787, 532 5365 | F. +62-31-532 0049
P. +62-361-485 854, 746 9449 | F. +62-361-485 854
Branch Office:
Jakarta. Wisma Keiai Building 19th Floor, Jl. Jenderal Sudirman Kavling 3 Jakarta 10220 – Indonesia Balikpapan. Sentra Eropa II AB - 5 No. 1 Balikpapan Baru, Kalimantan Timur, Indonesia
P : +62 21 572 3322 (hunting) | F: +62 21 572 3323 P. +62-542-720 4205, 721 2085 | F. +62-542-721 2087
Jakarta. Jl. Pancoran Barat VII, Duren Tiga, Jakarta 12760, Indonesia | P. +62-21-7919 2468 | F. +62-21-7919 2473
Timika. Jl. Cendrawasih Jalur SP 2, Timika, Papua 99910, Indonesia | P. +62-901-323 817 | F. +62-901-323 817
Medan. Jl. Pinang Baris No. 28, Komp. Imperium, Kel. Sunggal, Medan 20128, Sumatera Utara, Indonesia
P. +62-61-8002 5528, 8002 5828 | F. +62-61-8002 5628
24 HOUR

www.daikinapplied.co.id
Another Quality Product by
TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION

OUTDOOR UNIT Cooling Only, R407C INDOOR UNIT


MODEL: MMC 75B, 100/125B MODEL
INDOOR UNIT
OUTDOOR UNIT
MFS 75A
M4MC 75B
MFS 100A
M4MC 100B
MFS 125A
M4MC 125B
MFS 150A
M4MC 150C
MFS 200 A2
M4MC 100 B x 2
MODEL: MFS 75A
(STANDARD VERTICAL AIR DISCHARGE) NOMINAL COOLING CAPACITY Btu/h 75,000 100,000 125,000 150,000 200,000
REFRIGERANT R407C
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 380-415 / 3 / 50
TYPE CENTRIFUGAL / DIRECT DRIVEN BELT DRIVE

BLOWER & MOTOR


QUANTITY 1 2 2 2 1 ( Twin Blower)
NOMINAL AIR FLOW CFM 2,000 3,000 3,500 4,000 5,800
OUTLET VELOCITY m/s 9.41 8.60 10.00 11.40 9.4
MOTOR OUTPUT W 500 375 x 2 500 x 2 500 x 2 1,500
CAPACITOR SIZE Mf 16 7.5 16 16 TOP VIEW

RATED RUNNING CURRENT (EACH) A 3.7 1.7 3.25 3.7 3.4


FAN MOTOR POLES 4 6 4 4 4
EXTERNAL STATIC PRESSURE inWG 0.4 0.4 0.4 0.4 0.6
MATERIAL COPPER

TUBE
DIAMETER mm 9.52
THICKNESS mm 0.3 R

MATERIAL ALUMINIUM
THICKNESS mm/in 0.11

COIL

FIN
ROWS 4 3 3 4
FIN PER INCH 12 12 12 12
FACE AREA ft2 5 9 9.5 9.5 12.95

INDOOR
AIR VELOCITY FPM 380 317 360 399
AIR PRESSURE DROP inWG 0.35 0.2 0.25 0.38
MATERIAL ELECTRO GALVANISHED MILD STEEL
CASING
FINISH EPOXY POLYSTER POWDER COATING
HEIGHT mm 1,800 1,900 1,900 1,900 1,920
DIMENSION WIDTH mm 530 530 530 530 1,420
DEPTH mm 700 1,050 1,050 1,050 700
WEIGHT kg 110 160 165 170
THERMAL EXPANSION
CONTROL ROOM TEMPERATURE
THERMOSTAT ELECTRONIC CONTROL VALVE
PIPING GAS in 1 1-1/8 1-3/8 1-3/8 1-1/8
CONNECTION LIQUID in 1/2 5/8 5/8 5/8 5/8
STEEL PIPE 1 ( MALE
CONDENSATE DRAIN SIZE
STEEL PIPE 1" THREADED ) FRONT VIEW
SIDE VIEW SIDE VIEW BACK VIEW
TYPE 70% EFICIENCY WASHABLE FILTER SARANET

FILTER
SIZE WIDTH x HEIGHT mm 545 x 908 450 x 963 587 x 716
MODEL: MMC 150C THICKNESS mm 12 6
QUANTITY 1 2 MODEL: MFS 100A/125A/150A
(STANDARD VERTICAL AIR DISCHARGE–NON CONVERTIBLE) PACKING
HEIGHT mm/in 2,000 2,050 2,060
WIDTH mm/in 680 680 1,666
DIMENSION
DEPTH mm/in 955 1,305 850
TYPE SCROLL DIMENSION
POWER SOURCE V/Ph/Hz 415 / 3 /50 380-415 / 3 / 50 MODEL
Liquid Suc?on
RATED RUNNING CURRENT A 13.6 16.9 17.9 23.5 15.9

COMP
LOCKED ROTOR AMPS A 95 125 110 198 100 5/8 " 1-1/8 "
RATED INPUT POWER W 6,810 9,040 10,200 13,300 8,540 125 5/8 " 1 - 3/8 "
PROTECTION DEVICE OVERLOAD PROTECTION AND AUTO RESET HIGH/LOW PRESSURE SWITCH 150 5/8 " 1- 3/8 "
LUBRICANT EMKARATE RL 32-3MAF TOP VIEW

FAN TYPE / DRIVE PROPELLER / DIRECT


BLADE MATERIAL ALUMINIUM
DIAMETER mm/in 660.4 / 26.0 762.0 / 30.0 660.4 / 26.0

FAN
POWER SOURCE V/Ph/Hz 415 /3 /50 415 / 3 / 50 380-415/3/50
RATED RUNNING CURRENT A 1.40 1.50 1.43 4.35 1.5 R

RATED INPUT POWER W 680 660 640 3,200 466


MATERIAL COPPER

TUBE
OUTDOOR
DIAMETER mm/in 9.52 (3/8)
THICKNESS mm 0.3
MATERIAL ALUMINIUM

COIL
THICKNESS mm 0.11

FIN
NUMBER x ROWS 2x1 12 2x2 2x2
FIN PER INCH 14 19 16 14 12
FACE AREA ft2 19.00 13.38 19.00
HEIGHT mm 946 1,041 946
DIMENSION WIDTH mm 1,116
DEPTH mm 939
WEIGHT kg 162 193 224 193
MATERIAL ELECTRO-GALVANISED MILD STEEL
CASING
FINISH EPOXY POLYSTER POWDER COATING
SOUND PRESSURE LEVEL dBA 70 72 75 77 72
REFRIGERANT Type R407C
PIPING GAS in 1 1-1/8 1-3/8 1-3/8 1-1/8
FRONT VIEW
CONNECTION LIQUID in 1/2 5/8 SIDE VIEW SIDE VIEW BACK VIEW

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).
6
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).
5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.