The ideal air conditioning system for

small offices and shops


Extending the core “5S” concept—Space saving, Sufficient capacity, Slim design, Sound-
reduced operation and Single phase power supply—Daikin’s VRVIII-S offers added value
with the “1E” concept—Easy installation. With all these features and more, we proudly
Volume
present the ideal air conditioning system designed for small-sized buildings.
Slim, compact and sufficient capacity Approx. 50%
reduction

S
The VRVIII-S is highly space saving, featuring slim and compact
outdoor units. It is suitable for small offices and shops with capacities
of 4, 5 and 6 HP.

765 mm
320 mm

The 5S+1E concepts of 635 mm


Footprint
Approx. 40% 900 mm
VRVIII
VRVIII reduction (5 HP)
(5 HP) (4, 5, 6 HP)
(4, 5, 6 HP)

5S
concept Space saving
Sufficient capacity
Slim design
Sound-reduced operation

E
Single phase power supply
Outdoor unit can be installed
on a balcony
Easy installation
1E
The compact, trunk-shaped outdoor unit can easily
be installed on a balcony, realising complete system
installation within each floor. This enables more
concept useful utilisation of the space on the building rooftop.

Contents
Introduction.......... page 1 Indoor unit lineup..... page 15 Option list............ page 33
Indoor units......... page 33
Main features........ page 3 Specifications........... page 25 Outdoor units.......page 35
Indoor units............... page 25 Control systems...page 35
1
Control systems... page 9 Outdoor units............ page 32 2
MAIN FEATURES
Wide range of choices
To suit the variety of rooms found in small offices
Indoor units
and shops, the VRVIII-S system offers wide range of 14 types 71 models*
indoor and outdoor units. A wide range of indoor units includes
VRVIII-S indoor and outdoor units are almost as easy 71 models in 14 types. The indoor
to install as residential air conditioning systems, units can be selected to match every
making them ideal for small offices and shops. room and preference.

Outdoor units
3 models
Outdoor unit can be selected from three
models to provide the power that suits
your needs. The trunk-shaped outdoor unit
can be neatly installed outside the office.
Indoor unit lineup 14 types 71 models*
Outdoor unit lineup Type Model Name 20 25 32 40 50 63 80 100 125 140
Model Name RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 6 HP
Capacity Index 20 25 31.25 40 50 62.5 80 100 125 140
Capacity Range 4 HP (11.2 kW) 5 HP (14.0 kW) 6 HP (15.5 kW) Ceiling Mounted FXFQ-LU
Cassette
(Round Flow)
Capacity Index 100 125 140 Ceiling Mounted FXZQ-MVE
Cassette
(Compact Multi Flow)
Ceiling Mounted FXCQ-MVE
Cassette
(Double Flow)
Ceiling Mounted FXKQ-MAVE
Cassette Corner

FXDQ-PBVE
(with drain pump)

Slim Ceiling
Mounted Duct FXDQ-NBVE
(with drain pump)

Ceiling Mounted FXMQ-PVE


Duct

Ceiling Suspended FXHQ-MAVE

Wall Mounted FXAQ-PVE


New New New New New New New

Floor Standing FXLQ-MAVE

Concealed FXNQ-MAVE
Floor Standing

Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.

Connection unit series indoor units (50 Hz only)


Type Model Name Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 3 HP 4 HP 5 HP
Capacity Index 20 25 31.25 40 50 71 100 125
Connection Unit — BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE
Ceiling Suspended FXUQ-MAV1
Cassette

Note: BEV units are necessary for Connection unit series indoor units.

3 4
MAIN FEATURES
Energy efficiency and quiet operation A collection of cutting-edge technologies
Outdoor units use Daikin’s unique scroll compressor to realise energy saving
realises efficient and quiet operation.
performance and quiet operation. The high efficiency compressor to achieve a higher COP
1 Compressor equipped with Reluctance DC motor 3
High COP
Daikin DC inverter models are equipped with the Reluctance DC
High COP during both cooling and achieved
in all ranges! motor for compressor. The Reluctance DC motor uses 2 different 2

heating operations VRVII-S


Previous model
types of torque, neodymium magnet*1 and reluctance torque*2. This
motor can save energy because it generates more power with a
RXYM-MVM
smaller electric power than an AC or conventional DC motor.
One of the top features of the VRVIII-S is Cooling 4 HP 3.65
Reluctance DC motor 1
its energy efficiency. It achieves high COP 5 HP 3.28 90

Motor efficiency (%)


during cooling and heating operations by 6 HP 2.92 80
employing Daikin’s unique scroll Heating 4 HP 3.68 Conventional DC motor

compressor. 5 HP 3.41
70 More than 20% RX(Y)MQ4PVE
RX(Y)MQ5PVE
RX(Y)MQ6PVE
6 HP 3.19 60 AC motor

Above values are based on the following nominal conditions: Reluctance


50 DC motor
• 2 Ceiling Mounted Cassette (Round Flow) type units are connected (4 HP: 0 30 60 90 120
FXFQ50P x 2; 5 HP: FXFQ63P x 2; and 6 HP: FXFQ63P + FXFQ80P.) Rotational speed (rps)
• Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB.
• Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Small load Large load
Low capacity High capacity

Quiet operation provides Note: Data are based on studies conducted under

luxurious comfort Lower operation sound is achieved controlled conditions at a Daikin laboratory
using Daikin products.
in cooling operation! 1 dB(A) reduced
*1 A neodymium magnet is approximately 10 times
Quietness is yet another important feature in each model! stronger than a standard ferrite magnet.
VRVII-S *2 The torque created by the change in power
of Daikin’s VRVIII-S system. To reduce Previous model
RXYM-MVM between the iron and magnet parts.
noise and realise comfortable operation,
latest technologies and features are Cooling 4 HP 51 -1dB(A) 50
>> Smooth sine wave DC inverter
52
Sine wave DC inverter
applied to the outdoor units. 5 HP -1dB(A) 51 Use of an optimised sine wave smoothes motor rotation, further improving
operating efficiency.

Nighttime quiet operation function


Operation sound level selectable 2 Smooth Air Inlet Bell Mouth and Aero Spiral Fan
With the bent Without the bent
from 3 steps for the night mode Mode 1. Automatic mode
These two features work to reduce sound. blade edge blade edge
Mode 1. Automatic mode
Guides are added to the bell mouth intake to
Set on the outdoor PCB. Time of maximum
Capacity %

temperature is memorised. The low operating mode


Peak in outdoor temperature reduce turbulence in the airflow generated by
100
will become active 8 hours*1 after the peak fan suction. The Aero Spiral Fan features fan
temperature in the daytime, and operation will return to blades with the bent blade edges, further
normal 10 hours*2 after that. The operation sound 8 hrs 10 hrs
(Initial setting) (Initial setting) reducing turbulence.
Load %

level for the night mode can be selected from 47 dB(A) 50 Escaping eddies are sucked in by
(Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3). the bent blade edges, reducing
overall turbulence.

Mode 2. Manual mode 0


50
Night Mode 3 DC fan motor DC motor efficiency
Operation sound dB(A)

Starting time and ending time can be input. (An external


control adaptor for outdoor unit, DTA104A61 or
Step 1 max. - 3 dB(A)
( 4 HP/11.2 kW)
Step 1: 47 dB(A) Efficiency improved in all areas compared (comparison with AC motor)
100
DTA104A62, and a locally obtained timer are 47
Step 2 max. - 6 dB(A)
to conventional AC motors, especially at
necessary.) ( 4 HP/11.2 kW) Step 2: 44 dB(A)
low speeds. 80
44 DC motor

Efficiency (%)
Step 3 max. - 9 dB(A) Approx.
Step 3: 41 dB(A)
Mode 3. Combined mode ( 4 HP/11.2 kW) DC fan motor structure 60 20%
41 increase
Combinations of modes 1 and 2 can be used Night mode starts Night mode ends 40 Approx.
depending on your needs. 8:00 12:00 16:00 20:00 0:00 4:00 8:00 40% AC motor
Note: Data are based on
*1. Initial setting. Can be selected from 6, 8 and 10 hours. Note: • This function is available in setting at site. 20 increase
studies conducted under
*2. Initial setting. Can be selected from 8, 9 and 10 hours. • The relationship of outdoor temperature (load) and time shown in the 0 controlled conditions at
graph is just an example.
200 300 400 500 600 700 800 900 1000 a Daikin laboratory.
The capacity reduction rate differs depending on the operation sound level
step selected.
Motor speed (rpm)

5 6
MAIN FEATURES
Design flexibility Easy installation
VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and A variety of functions are provided that make installation easier, such as simple wiring
multiple indoor unit combinations, which provides generous freedom for office and shop and piping and automatic test operation.
design both inside and out. Previous model
VRVII-S

As many as 9 indoor units can be Easy wiring


connected to a single outdoor unit A printed circuit board has been
adopted that is easy to see and wire
Multiple indoor unit combinations are possible.* As many as 9 indoor units can be connected
during installation.
to a single outdoor unit, making the VRVIII-S a remarkably versatile system.
* Total capacity index of connectable indoor units must be 50 - 130 % of the capacity index of the outdoor unit.

For a 6 HP installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check,
1 2 3 4
Max.
including wiring, shutoff valves, and sensors. The results are returned automatically after the
9 units
check finishes.
>> Max. 8 indoor units for a 5 HP
installation
5 6 7 8 9
>> Max. 6 indoor units for a 4 HP
installation
Simple wiring and piping connection
Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily.

Long piping design possible >> Super wiring system


A super wiring system is used to enable shared use of the
The VRVIII-S provides the long piping wiring between indoor and outdoor units and the central
length possibility of 150 m, with a total piping *2 control wiring, with a relatively simple wiring operation.
length of 300 m. If the outdoor unit is Max. 50 m*1 The DIII-NET communication system is employed to
Level enable the use of advanced control systems.
installed above indoor units the level difference
difference can be up to a maximum of 50 m. Max. 15 m
These generous allowances facilitate an Level difference
between indoor Outdoor unit
extensive variety of system designs. units
Central
Actual piping length Total piping length remote
Max. 150 m Max. 300 m Notes: *1. 40 m when the outdoor unit is installed below indoor units. controller
Indoor unit
*2. Maximum piping length between the indoor unit and the first branch is 40 m.

>> REFNET piping system


Daikin’s advanced REFNET piping system makes
installation easy. Only two main refrigerant lines are
Wide operation temperature range Certified operation temperature range
required in any one system. REFNET greatly reduces the
50 46CDB
imbalances in refrigerant flow between units, while using
small-diameter piping.
40
Outdoor temperature (CWB)
Outdoor temperature (CDB)

The versatile operation range of the VRVIII-S system 30 20 15.5CWB


works to reduce limitations on installation locations. The 10
20
operation temperature range for heating goes all the way
0
down to -20C, while cooling can be performed with 10
outdoor temperatures as high as 46C. Both these 0 -10
achievements are due to the adoption of a high-pressure -5CDB -20
-10 –20CWB
dome-type compressor.
Cooling Heating

7 8
CONTROL SYSTEMS
Control systems
The VRVIII-S system uses the same DIII-NET communication system as the
VRV, enabling the use of advanced control systems.

Individual control systems


Navigation remote controller (Wired remote controller) (Option) Wireless remote controller (Option)
The same operation modes and settings as with wired remote controllers are possible.
Large buttons and arrow keys for easy operation. A compact signalng is
Guide on display gives an explanation of each setting. included.
• A signallow,
Backlight and dot matrix LCD display for easy viewing. Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted
Weekly schedule timer can be set up easily. type is mounted into the indoor unit.
Signal receiver unit can be
10 display languages are available.
installed on the panel
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, ex. Ceiling Mounted Cassette (Round Flow) type
Russian and Turkish)
Signal receiver unit
BRC1E61 (Separate type)

Wired remote controller (Option) Wired remote controller Wireless remote Signal receiver unit
(Installed type)
controller

Displays current airflow, swing, temperature,


with weekly schedule timer (Option) *Wireless remote controller ander unit are sold as a set.
operating mode and timer settings. Adds weekly schedule timer function. *Refer to page 35 for the name of each model.

Simplified(Option)
The remote controller has
centralised its frequently used
operation selectors and switches
(on/off, operation mode,
temperature setting and airflow
volume), making itself suitable
for use in hotel rooms or
conference rooms.
The exposed type remote
BRC1D61 controller is fitted with a
BRC1C62 Concealed type
Notes: 1. Standard remote controllers (BRC1C62) not required. (For hotel use) thermostat sensor.
2. If the BRC1D61 is connected to the centralised remote controllers (BRC3A61)
(DCS303A51, DCS302CA61, DCS301BA61, DST301BA61), the
schedule function is not available. Exposed type
(BRC2C51) The concealed type remote controller smartly fits into a
night table or console panel in a hotel room.
The wired remote controller supports a wide range of control functions
Control of Cool/Heat In all the series of VRV, Cool/Heat changeover in the same refrigerant Wide variation of remote controllers for indoor units
changeover circuit can be changed by the remote controller of the indoor unit. 1 Control by two remote controller
The indoor unit can be connected by the two FXFQ FXZQ FXCQ FXKQ FXDQ FXMQ FXHQ FXAQ FXL(N)Q FXUQ
remote controller, for example one in the room
Group control and the other one in the control room, which Navigation remote controller
Equipment One remote controller can can control the operation of indoor unit freely. (Wired remote controller)
Outdoor control the operation of max.16 (BRC1E61)
unit related to the (The last command has a priority.) Of course,
central control indoor units at the same time.
the group control by two remote controller is
also possible. Wired remote controller
(BRC1C62)

2 Remote control
Remote controller
Indoor unit Wired remote controller with
The wiring of remote controller can be
Remote controller weekly schedule timer
extended to max. 500 m and it is possible (BRC1D61)
to install the remote controllers for the
different indoor units in one place.
Wireless remote controller*
(Installed type
Remote
controller 3 Control for the combined operation
The operation of Heat Reclaim Ventilator
Forced OFF be controlled by the remote controller of the Wireless remote controller*
input (Separate type signal receiver unit)
indoor unit. Of course, the remote controller
can display the time to clean the filter.
Heat Reclaim
Ventilator
Remote
Simplifiedremote controller
Remote controller controller Remote controller (Exposed type)
Remote controller Remote controller 4 Expansion of system control (BRC2C51)

The system can be expanded to add


1 2 3 4 several controllers, such as BMS, Forced Simplifiedremote controller
OFF input and etc. (Concealed type: for Hotel use)
(BRC3A61)

9 Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. *Refer to page 35 for the name of each model. 10
CONTROL SYSTEMS
Centralised control systems
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Residential central remote controller* (Option)
Optional controllers for centralised control can be combined and optimised in Max. 16 groups of indoor units can be easily controlled with
accordance with building scale and purpose. the large LCD panel.
Max. 16 groups (128 indoor units) controllable
System integration with various air-conditioning peripheral equipment such as Backlight and large LCD panel for easy readability
ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.
Heat Reclaim Ventilator is easy. All indoor units can be turned on or off at once with “ALL” button.
Each group has a dedicated button for convenience.

Wiring can be run up to a total length of 2 km, and adapts easily to large-scale DCS303A51
Outside temperature display
*For residential use only. Cannot be used with other centralised control equipment.
system expansion.

Central remote controller (Option)


Max. 64 groups (zones) of indoor units can be
Unified on/off
controller
controlled individually same as LCD Remote controller.
(DCS301BA61) Max. 64 groups (128 indoor units) controllable
Connection of Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,
up to 8 units
Independent
possible which can control from 2 different places.
and centralised
Address setting of central control can be control of Heat Zone control
performed from the remote controller. Reclaim
Malfunction code display
Ventilator
possible. Max. wiring length 1,000 m (Total: 2,000 m)
DCS302CA61
Connectable with Unified ON/OFF controller, schedule timer and BMS system
Airflow volume and direction can be controlled individually for indoor units in each group operation.
Connectable number of
Ventilation volume and mode can be controlled for Heat Reclaim Ventilator.
centralised control
equipment Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.
Central remote Group control of up to 16 units is possible 1
2 units
controller (group control via automatic address setting)
Unified on / off
8 units
controller
Unified ON/OFF controller (Option)
Schedule timer 1 unit
Max. 16 groups of indoor units can be operated
simultaneously/individually.
System without remote control is also available. Max. 16 groups (128 indoor units) controllable
2 remote controllers can be used to control from 2 different places.
Forced Operating status indication (Normal operation, Alarm)
shut-down
input Centralised control indication
Central control Wiring adaptor
adaptor kit for other air- Outdoor-air Max. wiring length 1,000 m (Total: 2,000 m)
(DTA107A55) conditioners processing Compact size casing (Thickness: 16 mm)
(DTA103A51) unit can be
connected. Connectable with Central Remote controller, Schedule timer and BMS system
DCS301BA61
Central remote
controller Interface adaptor for SkyAir
(DCS302CA61) series (built-in indoor unit)
(DTA102A52)
Up to 2 units
connectable Schedule timer (Option)
Max. 128 indoor units can be operated as
6 cores 7 cores max. Interlink Building Management System programmed schedule.
(host computer monitor panel) also possible
Schedule timer (DST301BA61) Max. 128 indoor units controllable
1 unit connection possible; Unification adaptor for computerised When used in combination with a central remote controller, a maximum of 8 weekly schedule
8 weekly schedule control patterns possible control (DCS302A52)
patterns can be set, while the central controller can be used to select desired zones. Up to 2
ON/OFF pairs can be set per day.
1. Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. Max. 48 hours back up power supply
• Certain indoor units limit the functions of some control systems. Max. wiring length 1,000 m (Total: 2,000 m)
DST301BA61 Compact size casing (Thickness: 16 mm)
Connectable with Central Remote controller, Unified ON/OFF controller and BMS system

11 12
CONTROL SYSTEMS
Advanced control systems
New

One touch selection to total air comfort Communication functions in the user-friendly icon-based multilingual controller simplify
centralised control of the VRV system.
Daikin proudly introduces its new intelligent Touch Manager, a VRV system controller
featuring an array of simple, useful system management functions for added value.
system overview
Up to 2,560 groups (5,120 indoor units) can be controlled by one system
Dio Unit Di Unit
DEC102A51 DEC101A51
system overview (Option) (Option)

Internal modem New


(option) DCS601C51 Input Input (Key signal -
DCM601A51 System (Lights) General purpose ADP)
Air Conditioning
Network Service System

Phone line line Max. 64 groups Set temperature OFF


change command command
LAN

Internet
Intranet LAN iTM plus adaptor line iTM plus adaptor (Max. 7 adaptors)
Max. 50m

I/O expansion line Air Conditioning Network


Service System modem Via internet
USB memory Max. 500m for connections
RS-232C D -NET
Di/Pi port
Di/Pi line
Max. 200m
System
I/O System (Max. 30 modules) Components Indoor Unit
Heat Reclaim
D -NET Plus Adaptor Ventilator
Web Access ACC centre DCS601A52 (Option)
I/O module I/O module I/O module • Air Conditioning Network Service System
(Optional Maintenance Service)
Number of indoor units expanded from 64 to 128.
Fire alarm kWh meter

Web Access
Lighting Pump Fan Sensor

Features Features
✫ Central control
• Handy area settings simplify detailed management of VRV. Colour LCD touch panel icon display
• Display of floor plans enables a quick search of desired air conditioning units.
• Operation history shows manner of control and origin in past operations of air conditioning units. Small manageable size
✫ Remote access
• Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the Simplified engineering
intelligent Touch Manager.
Multi language (English, French, Italian, German,
• Authorised users can centrally control individual air conditioning units from their own computers.
✫ Automatic control Spanish, Dutch, Portuguese, Chinese and Korean)
• VRVs are controlled automatically throughout the year by the schedule function.
• Interlocking VRVs and other equipment enables easy automation of building facilities operation. Yearly schedule
• Setback adjusts temperature settings even when rooms are unoccupied.
✫ Energy management
Auto heat/cool change-over
• The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient Temperature limitation
operation.
✫ Troubleshooting Enhanced history function
• Contact information of maintenance contractors can be registered and displayed.
• E-mails are sent automatically to alert of malfunctions and potential trouble. Simple Interlock Function
• The intelligent Touch Manager can link to the Air Conditioning Network Service System for 24-hour monitoring of operating Built-in modem for connecting to Air Conditioning Network Service System (Option)
conditions and status.
✫ Scalability Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)
• A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings.
• Large building properties can also take advantage of the iTM integrator to link up and expand system up to 5 intelligent Touch Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)
Managers for integrated control.

13 14
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Round Flow) Type (Compact Multi Flow) Type
FXFQ25L/FXFQ32L/FXFQ40L
FXZQ20M/ FXZQ25M
FXFQ50L/FXFQ63L/FXFQ80L FXZQ32M/FXZQ40M
FXFQ100L/FXFQ125L FXZQ50M

360 airflow improves temperature distribution


and offers a comfortable living environment. Quiet, compact, and designed for user comfort
The industry’s first* Round Flow Ceiling Mounted Dimensions correspond with 600 mm X 600 mm
Cassette type offers 360 airflow with improved architectural module ceiling design
temperature distribution. specifications.
4-way flow Round Flow

Low operation sound level (dB(A))

FXZQ-M 20/25 32 40 50

Sound level 230 V 30/25 32/26 36/28 41/33


There are areas of There are much fewer (H/L) 240 V 32/26 34/28 37/29 42/35
uneven temperature. areas of uneven temperature.
*As of April 2004, the release date for Japan.

All models are lighter than the conventional ones.


Comfortable airflow
Ex: Models FXFQ25L-50L are 4.5 kg lighter
(reduced from 24 kg to 19.5 kg). 1 Wide discharge angle: 0 to 60
Drain pump is equipped as Auto swing Fixed angles: 5 levels
standard accessory, and the
850 mm
lift height has been improved 0 0 0 0
from 750 mm to 850 mm.
60
A modern sophisticated decoration panel has An antibacterial treatment that uses silver ions
60 60 60

been applied, with a panel surface that has been has been applied to the drain pan, preventing Angles can be also set on site to prevent drafts (0-35)
or soiling of the ceiling (25-60), other than standard setting (0-60).
treated with a dirt-repellant coating. the growth of slime, mould and bacteria that
Treated surface Untreated surface
cause blockages and odours.
Dirt and
2 2-, 3-, and 4-way airflow patterns are available,
Resists grime • Condition after
exposure to the The horizontal louvres prevent dew enabling installation in the corner of a room.
soiling
smoke of 600
condensation. Their non-flocking surfaces, which
Drain pump is equipped as standard
3
cigarettes in 1 m
enclosed space.
repel dirt, are easy to clean.
Control of the airflow rate has been improved accessory with 750 mm lift.
from 2-step to 3-step control.
The air filter has an anti-mould and antibacterial
Low operation sound level (dB(A)) treatment that prevents the growth of mould
FXFQ-L
Sound
25/32 40 50 63 80 100 125
generated from dust or moisture that may L-shaped 750 mm
level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 adhere to the filter. 4-way flow 3-way flow 2-way flow
(HH/H/L)
For 3-way or 2-way flow installation, the sealing member for air discharge
All-round flow 4-way flow 3-way flow L-shaped 2-way flow outlet (option) must be used to close each unused outlet.
Example of airflow patterns:
360 airflow is available, as well as 2- to
4-way flows, so you can choose the most
suitable airflow pattern depending on
location or room layout.

Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.
15 16
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Double Flow) Type Corner Type
FXCQ20M/FXCQ25M/FXCQ32M FXKQ25MA /FXKQ32MA
FXCQ40M/ FXCQ50M/ FXCQ63M FXKQ40MA /FXKQ63MA
FXCQ80M/FXCQ125M

Thin, lightweight, and easy to install in


Slim design for flexible installation
shallow ceiling spaces
The low profile unit (only 305 mm high) can Slim body needs only 220 mm space above Providing 3 different settings of standard,
be installed in a ceiling space as shallow the ceiling. If you use a panel spacer (option), draft prevention and ceiling soiling
as 350 mm. All models feature a compact the unit can be installed in the minimum space prevention, the auto swing mechanism
design with a depth of only 600 mm. of 195 mm. achieves even distribution of airflow and
room temperature.
Min.195 mm
(m)
305 mm Panel spacer 3
28˚C 26˚C
20 mm 24˚C
2 32˚C 30˚C
22˚C
(When a high-efficiency filter is attached, the
Single-flow type allows effective air discharge 1 20˚C
unit's height is 400 mm.)
from corner or from drop-ceiling.
0 1 2 3 4 5 6 (m)
Low operation sound level (dB(A)) Drain pump is equipped as standard
FXCQ-M 20 25/32 40/50 63 80 125 accessory with 500 mm lift. Front discharge is possible with an air
discharge unit (option), which allows the
Sound level 220 V 32/27 34/28 34/29 37/32 39/34 44/38
(H/L)
500 mm installation in the drop-ceiling or sagging wall.
240 V 34/29 36/30 37/32 39/34 41/36 46/40
Main body

Designed with higher airflow suitable for


Downward discharge
high ceiling application up to 3 metres.
Air discharge grille (Option)
Providing 2 different settings of standard
and ceiling soiling prevention, the auto
swing mechanism achieves even
Two types of optional high-efficiency filter are Set for front discharge using a suspended ceiling.
distribution of airflow and room
available (65% and 95%, colourimetric method). Main body
temperature.

Drain pump is equipped as standard A long-life filter (maintenance free up to one


accessory with 600 mm lift. year ) is equipped as standard accessory. Air discharge grille
(Option)
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

600 mm Major maintenance work can be performed by


Downward discharge is shut off and air is blown straight out
removing the panel. A flat-type suction grille (front discharge).

and a detachable blade make cleaning easy. A long-life filter (maintenance free up to one
year ) is equipped as standard accessory.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

17 18
INDOOR UNIT LINEUP
Slim Ceiling Mounted Ceiling Mounted
Duct Type Duct Type
FXMQ20P/FXMQ25P/ FXMQ32P
Slim design, quietness and FXMQ40P/FXMQ50P/ FXMQ63P
FXMQ80P/FXMQ100P/ FXMQ125P
static pressure switching FXMQ140P

Suited to use in drop-ceilings!


FXDQ40NB/FXDQ50NB/FXDQ63NB
Middle and high static pressure
FXDQ20PB/FXDQ25PB/FXDQ32PB allows for flexible duct design
Only 200 mm in height, this model can be A DC fan motor increases the external static
Only 700 mm in width and 23 kg in weight, this
installed in rooms with as little as 240 mm depth pressure capacity range to include middle to high
model is suitable to install in limited spaces like
between the drop-ceiling and ceiling slab. static pressures, increasing design flexibility.
drop-ceilings in hotels.
30 Pa–100 Pa for FXMQ20P-32P
30 Pa–160 Pa for FXMQ40P
Great for 50 Pa–200 Pa for FXMQ50P-125P
hotel use! 50 Pa–140 Pa for FXMQ140P

All models are only 300 mm in height, an


200 mm
900 mm improvement over the 390 mm height of
200 mm conventional models. The weight of the
Only 700 mm 1,100 mm in width for the FXDQ63NB model. FXMQ40P has been reduced from 44 kg to
28 kg.

Suspension bolt* Air filter


300 mm
AIR 240 mm Easy installation in buildings
with narrow ceiling spaces
Discharge grille*
Suction grille*
AIR
*To be obtained locally Drain pump is equipped as standard accessory
with 700 mm lift.
External static pressure selectable by remote 700 mm
controller switching make this indoor unit a very
comfortable and flexible model. Ceiling
10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models. Improved ease of installation
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.
Control of the airflow rate has been improved Airflow rate can be controlled using a remote
from 2-step to 3-step control. controller during test operation.
FXDQ-PB and FXDQ-NB models are available in
two types to suit different installation conditions. conventional model, the airflow rate was controlled
Low operation sound level (dB(A))
FXDQ-PB/NBVE: with a drain pump (750 mm lift) FXMQ-P 20/25 32 40 50 63 80/100 125 140
from the PC board. It is automatically adjusted to
as a standard accessory Sound the range between approximately 10% of the rated
level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43
Control of the airflow rate has been improved (HH/H/L) HH tap airflow for FXMQ20P-125P.
from 2-step to 3-step control.
Improved ease of maintenance
Low operation sound level Energy-efficient
(dB(A)) 750 mm The drain pan can be detached for easy
FXDQ-PB/NB 20/25/32 40 50 63 The adopted DC fan motor is much more cleaning. An antibacterial treatment that uses
Sound level 33/31/29 34/32/30 35/33/31 36/34/32
efficient than the conventional AC motor, silver ions has been applied to the drain pan,
(HH/H/L)
The values of operation sound level represent those for rear-suction operation.
Ceiling yielding an approximate 20% decrease in preventing the growth of slime, mould and
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
Values are based on the following conditions:
energy consumption. (FXMQ125P) bacteria that cause blockages and odours.
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.

19 20
INDOOR UNIT LINEUP
Ceiling Suspended Type Wall Mounted Type

FXAQ20P/FXAQ25P
FXHQ32MA/FXHQ63MA New FXAQ32P/FXAQ40P
FXHQ100MA
FXAQ50P/FXAQ63P

Stylish flat panel design harmonised


Slim body with quiet and wide airflow with your interior décor
Stylish flat panel design creates a graceful
Adoption of QUIET STREAM FAN
harmony that enhances any interior space.
Uses the quiet stream fan and many
advanced technologies.
Sound absorption
material
Flat panel can be cleaned with only the single
pass of a cloth across their smooth surface.
Flat panel can also be easily removed and
washed for more thorough cleaning.

Turbulent flow
is produced
Quiet stream fan
Low operation sound level (dB(A))
Straightening vane
FXAQ-P 20 25 32 40 50 63
Sound level
(H/L) 35/31 36/31 38/31 39/34 42/37 47/41
Low operation sound level (dB(A))
FXHQ-MA 32 63 100

Sound level 36/31 39/34 45/37 Drain pan and air filter can be kept clean by
(H/L) mould-proof polystyrene.

Installation is easy
Vertical auto-swing realises efficiency of air
Drain pump kit (option) can be easily
distribution. The louvre closes automatically
incorporated.
when the unit stops.
600 mm

Maintenance is easy 5 steps of discharge angle can be set by


Non-dew Flap with no implanted bristles remote controller.
Drain pump kit
(built inside main unit) Bristle-free Flap minimises
contamination and makes Drain pump kit is available as optional accessory,
cleaning simpler. Discharge angle is automatically set at the which lifts the drain 1,000 mm from the bottom of
Wide air discharge openings produce a Non-dew Flap same angle as the previous operation when the unit.
Easy-to-clean flat design restarting. (Initial setting: 10˚ for cooling and
spreading 100 airflow. Height of drain-up
Maintenance is easier because servicing can 70˚ for heating)
be performed from below the unit.
1,000 mm
A long-life filter (maintenance free up to one Flexible installation
year) is equipped as standard accessory. Drain pipe can be fitted to from either left or
right sides. Indoor unit
100 Drain pump kit

21 22
INDOOR UNIT LINEUP
Connection unit series indoor units

Floor Standing Type Ceiling Suspended


Cassette Type (50 Hz only)
FXLQ20MA/ FXLQ25MA FXUQ71MA
FXLQ32MA/FXLQ40MA FXUQ100MA
FXLQ50MA/ FXLQ63MA FXUQ125MA

This thin indoor unit achieves optimum


Suitable for perimeter zone air conditioning air distribution, and can be installed
Floor Standing types can be hung on the wall for easier floor without the need for ceiling cavity
cleaning. Running the piping from the back allows the unit to be
hung on walls. Cleaning under the unit, where dust tends to Depending on installation site requirements or
accumulate, is considerably easier. room conditions, 2-way, 3-way and 4-way
discharge patterns are available.
The adoption of a fibre-less discharge grille featuring an original
design to prevent condensation also helps prevent staining and
makes cleaning easier.
4-way airflow The 3-way airflow can distribute
from the centre of the store. comfortable air throughout the room.
A long-life filter (maintenance free up to one year ) is equipped
as standard accessory.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Wall hanging Floor installation

Concealed Floor
Standing Type Only one unit is needed to distribute comfortable air
throughout an L-shaped store.

FXNQ20MA/ FXNQ25MA
FXNQ32MA/ FXNQ40MA
FXNQ50MA/ FXNQ63MA

Designed to be concealed in the perimeter skirting-wall Connection unit Connection unit is the device for connecting above indoor unit to VRVIII-S.
BEVQ71MA/BEVQ100MA/BEVQ125MA
The unit is concealed in skirting-wall of perimeter, that enables
Refrigerant piping layout External wiring layout
to create high class interior design. *1 Maximum piping length
Connection unit for indoor unit Model between the BEV unit
and the indoor unit.

The connecting port faces VRV -S series


outdoor unit
FXUQ-MA 5m
Notes:
downward, greatly facilitating Gas pipe
BEVQ-MAVE Super wiring ( DIII-NET ) • When connecting centralised-control device, it is
Liquid necessary to install an interface adaptor for an
on-site piping work. Connecting
port
pipe Single-phase 220-240 V
power supply indoor unit (DTA102A52).
• Connection unit BEVQ-MA is necessary for each
Indoor unit indoor unit.
Refrigerant • The refrigerant piping height difference between
A long-life filter (maintenance piping the indoor units and the BEV unit must be within
4 m.
free up to one year ) is equipped Piping length*1 Indoor unit
• The BEV unit must be installed within a
maximum height difference between indoor units
of 15 m.
as standard accessory. Applies also to Floor Standing type (FXLQ-MA).
Remote controller • Branching of the refrigerant piping is not
possible downstream of the BEV unit.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

23 24
SPECIFICATIONS
INDOOR UNITS Ceiling Mounted Cassette (Double Flow) Type
MODEL FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
Ceiling Mounted Cassette (Round Flow) Type Power supply 1-phase, 220 - 240 V/220 V, 50 Hz

MODEL FXFQ25LU FXFQ32LU FXFQ40LU FXFQ50LU FXFQ63LU FXFQ80LU FXFQ100LU FXFQ125LU kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 6,300 8,000 12,500
Btu/h(*1) 7,800 9,900 12,600 16,000 19,800 24,900 31,700 49,500
Power supply 1-phase, 220 -240 V/220 V, 50 Hz Cooling capacity
kW (*1) 2.3 2.9 3.7 4.7 5.8 7.3 9.3 14.5
kcal/h(*1) 2,500 3,200 4,000 5,000 6,300 8,000 10,000 12,500
(*2) 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
Btu/h(*1) 9,900 12,600 16,000 19,800 24,900 31,700 39,600 49,500
Cooling capacity Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900 8,600 13,800
kW (*1) 2.9 3.7 4.7 5.8 7.3 9.3 11.6 14.5
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 34,100 54,600
(*2) 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0
Heating capacity kcal/h 2,800 3,400 4,300 5,400 6,900 8,600 10,800 13,800
Casing Galvanised steel plate
Btu/h 10,900 13,600 17,100 21,500 27,300 34,100 42,700 54,600
Airflow rate (H/L) m3/min 7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25
kW 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
cfm 247/177 318/230 318/230 424/318 424/318 582/459 918/741 1,165/883
Casing Galvanised steel plate
Sound level (H/L) 220 V dB(A) 32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38
Airflow rate (HH/H/L) m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5
240 V 34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794
Dimensions (HXWXD) mm 305X775X600 305X775X600 305X775X600 305X990X600 305X990X600 305X1,175X600 305X1,665X600 305X1,665X600
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
Machine weight kg 26 26 26 31 32 35 47 48
Dimensions (HXWXD) mm 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5
Machine weight kg 19.5 19.5 19.5 19.5 22 22 25 25 Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9
Liquid (Flare) mm 6.4 6.4 6.4 6.4 9.5 9.5 9.5 9.5
Drain VP25 (External Dia, 32/Internal Dia, 25)
Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9
Model BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1
Drain VP25 (External Dia, 32/Internal Dia, 25)
Panel Colour White (10Y9/0.5)
Model BYCP125K-W1 (Option)
Dimensions (HXWXD) mm 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680
Panel Colour Fresh white
Weight kg 8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0
(Option)
Dimensions (HXWXD) mm 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950
Weight kg 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Ceiling Mounted Cassette Corner Type
Ceiling Mounted Cassette (Compact Multi Flow) Type MODEL FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE
MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Power supply 1-phase, 220- 240 V/220 V, 50 Hz

Power supply 1-phase, 220-240 V/220 V, 50 Hz kcal/h(*1) 2,500 3,200 4,000 6,300
Btu/h(*1) 9,900 12,600 16,000 24,900
kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 Cooling capacity
kW (*1) 2.9 3.7 4.7 7.3
Btu/h(*1) 7,800 9,900 12,600 16,000 19,800
Cooling capacity (*2) 2.8 3.6 4.5 7.1
kW (*1) 2.3 2.9 3.7 4.7 5.8
Heating capacity kcal/h 2,800 3,400 4,300 6,900
(*2) 2.2 2.8 3.6 4.5 5.6
Btu/h 10,900 13,600 17,100 27,300
Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400
kW 3.2 4.0 5.0 8.0
Btu/h 8,500 10,900 13,600 17,100 21,500
Casing Galvanised steel plate
kW 2.5 3.2 4.0 5.0 6.3 Airflow rate (H/L) 50 Hz m3/min 11/9 11/9 13/10 18/15
Casing Galvanised steel plate cfm 388/318 388/318 459/353 635/530
Airflow rate (H/L) m3/min 9/7 9/7 9.5/7.5 11/8 14/10 Sound level (H/L) 220 V dB(A) 38/33 38/33 40/34 42/37
cfm 318/247 318/247 335/265 388/282 493/353 240 V 40/35 40/35 42/36 44/39
dB(A) Dimensions (HXWXD) mm 215X1,110X710 215X1,110X710 215X1,110X710 215X1,310X710
Sound level 30/25-32/26-32/29 30/25-32/26-32/29 32/26-34/28-33/29 36/28-37/29-36/30 41/33-42/35-41/34
(H/L) 230 V, 50 Hz-240 V, Machine weight kg 31 31 31 34
50 Hz-220 V,
Liquid (Flare) mm 6.4 6.4 6.4 9.5
Dimensions (HXWXD) mm 286X575X575 Piping
connections Gas (Flare) 12.7 12.7 12.7 15.9
Machine weight kg 18 Drain VP25 (External Dia, 32/Internal Dia, 25)
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 Model BYK45FJW1 BYK71FJW1
Piping Colour White (10Y9/0.5)
Panel
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7
(Option) Dimensions (HXWXD) mm 70X1,240X800 70X1,240X800 70X1,240X800 70X1,440X800
Drain VP20 (External Dia, 26/Internal Dia, 20)
Weight kg 8.5 8.5 8.5 9.5
Model BYFQ60B8W1
Note: Specifications are based on the following conditions;
Panel Colour White (6.5Y9.5/0.5)
•Cooling: Indoor temp.: (*1)27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2)27CDB, 19CWB, Outdoor
(Option) temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping
Dimensions (HXWXD) mm 55X700X700 55X700X700 55X700X700 55X700X700 55X700X700
length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. Sound
Weight kg 2.7 2.7 2.7 2.7 2.7 level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally
somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: (*1)27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2)27CDB, 19CWB,
Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent
piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity
index. Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these
values are normally somewhat higher as a result of ambient conditions.

25 26
SPECIFICATIONS
Slim Ceiling Mounted Duct Type (700 mm width type) Ceiling Mounted Duct Type
MODEL with
drain pump FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE MODEL FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE
Power supply 1-phase, 220-240 V/220 V, 50 Hz Power supply 1-phase, 220-240 V/220 V, 50 Hz

kcal/h(*1) 2,000 2,500 3,200 kcal/h(*1) 2,000 2,500 3,200 4,000 5,000

Btu/h(*1) 7,800 9,900 12,600 Btu/h(*1) 7,800 9,900 12,600 16,000 19,800
Cooling capacity Cooling capacity
(*1) 2.3 2.9 3.7 (*1) 2.3 2.9 3.7 4.7 5.8
kW kW
(*2) 2.2 2.8 3.6 (*2) 2.2 2.8 3.6 4.5 5.6

kcal/h 2,200 2,800 3,400 kcal/h 2,200 2,800 3,400 4,300 5,400

Heating capacity Btu/h 8,500 10,900 13,600 Heating capacity Btu/h 8,500 10,900 13,600 17,100 21,500

kW 2.5 3.2 4.0 kW 2.5 3.2 4.0 5.0 6.3

Casing Galvanised steel plate Casing Galvanised steel plate

m3/min 8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4 m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11 18/16.5/15
Airflow rate (HH/H/L) Airflow rate (HH/H/L)
cfm 282/254/226 282/254/226 282/254/226 cfm 318/265/230 318/265/230 335/282/247 565/459/388 635/582/530
1 1 1 1 1
External static pressure Pa 30-10 1 External static pressure Pa 30-100 30-100 30-100 30-160 50-200

Sound level (HH/H/L) 2 3 dB(A) 33/31/29 33/31/29 33/31/29 Sound level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35 41/39/37

Dimensions (HXWXD) mm 200X700X620 200X700X620 200X700X620 Dimensions (HXWXD) mm 300X550X700 300X550X700 300X550X700 300X700X700 300X1,000X700

Machine weight kg 23 23 23 Machine weight kg 25 25 25 28 36

Liquid (Flare) 6.4 6.4 6.4 Liquid (Flare) 6.4 6.4 6.4 6.4 6.4
Piping Piping
mm connections Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7
connections Gas (Flare) 12.7 12.7 12.7
Drain VP20 (External Dia, 26/Internal Dia, 20) Drain VP25 (External Dia, 32/Internal Dia, 25)

Slim Ceiling Mounted Duct Type (900/1,100 mm width type) MODEL FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE
with Power supply 1-phase, 220-240 V/220 V, 50 Hz
MODEL drain pump FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
kcal/h(*1) 6,300 8,000 10,000 12,500 14,300
Power supply 1-phase, 220-240 V/220 V, 50 Hz
Btu/h(*1) 24,900 31,700 39,600 49,500 57,000
kcal/h(*1) 4,000 5,000 6,300 Cooling capacity
(*1) 7.3 9.3 11.6 14.5 16.7
Btu/h(*1) 16,000 19,800 24,900 kW
Cooling capacity (*2) 7.1 9.0 11.2 14.0 16.0
(*1) 4.7 5.8 7.3
kW kcal/h 6,900 8,600 10,800 13,800 15,500
(*2) 4.5 5.6 7.1
Heating capacity Btu/h 27,300 34,100 42,700 54,600 61,400
kcal/h 4,300 5,400 6,900
kW 8.0 10.0 12.5 16.0 18.0
Heating capacity Btu/h 17,100 21,500 27,300
Casing Galvanised steel plate
kW 5.0 6.3 8.0
m3/min 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
Casing Galvanised steel plate Airflow rate (HH/H/L)
cfm 688/618/565 883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130
m3/min 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0
Airflow rate (HH/H/L) 1 1 1 1 1
External static pressure Pa 50-200 50-200 50-200 50-200 50-140
cfm 371/335/300 441/388/353 583/512/459
Sound level (HH/H/L) dB(A) 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
External static pressure Pa 44-15 1
Dimensions (HXWXD) mm 300X1,000X700 300X1,000X700 300X1,400X700 300X1,400X700 300X1,400X700
Sound level (HH/H/L) 2 3 dB(A) 34/32/30 35/33/31 36/34/32
Machine weight kg 36 36 46 46 47
Dimensions (HXWXD) mm 200X900X620 200X900X620 200X1,100X620
Liquid (Flare) 9.5 9.5 9.5 9.5 9.5
Machine weight kg 27 28 31 Piping
mm
Liquid (Flare) 6.4 6.4 9.5 connections Gas (Flare) 15.9 15.9 15.9 15.9 15.9
Piping Drain VP25 (External Dia, 32/Internal Dia, 25)
mm
connections Gas (Flare) 12.7 12.7 15.9
Note: Specifications are based on the following conditions;
Drain VP20 (External Dia, 26/Internal Dia, 20) •Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Note: Specifications are based on the following conditions;
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.
1: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for
FXDQ-PB models and 15 Pa for FXDQ-NB models.)
2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).
3: Values are based on the following conditions: FXDQ-PB external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.

27 28
SPECIFICATIONS
Ceiling Suspended Type Floor Standing Type/Concealed Floor Standing Type
MODEL FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE

Power supply 1-phase, 220-240 V/220 V, 50 Hz FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
kcal/h(*1) 3,200 6,300 10,000 Power supply 1-phase, 220 - 240 V/220 V, 50 Hz
Btu/h(*1) 12,600 24,900 39,600 kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 6,300
Cooling capacity
kW (*1) 3.7 7.3 11.6 FXLQ Btu/h(*1) 7,800 9,900 12,600 16,000 19,800 24,900
Cooling capacity
(*2) 3.6 7.1 11.2 kW (*1) 2.3 2.9 3.7 4.7 5.8 7.3
Heating capacity kcal/h 3,400 6,900 10,800 (*2) 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 13,600 27,300 42,700 Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900
kW 4.0 8.0 12.5 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Casing White (10Y9/0.5) kW 2.5 3.2 4.0 5.0 6.3 8.0
m3/min 12/10 17.5/14 25/19.5 Casing FXLQ: Ivory white (5Y7.5/1) / FXNQ: Galvanised steel plate
Airflow rate (H/L) FXNQ
cfm 424/353 618/494 883/688 Airflow rate (H/L) m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12
Sound level (H/L) dB(A) 36/31 39/34 45/37 cfm 247/212 247/212 282/212 388/300 494/388 565/424
Dimensions (HXWXD) mm 195X960X680 195X1,160X680 195X1,400X680 Sound level (H/L) 220 V dB(A) 35/32 35/32 35/32 38/33 39/34 40/35
Machine weight kg 24 28 33 240 V 37/34 37/34 37/34 40/35 41/36 42/37
Liquid (Flare) mm 6.4 9.5 9.5 Dimensions FXLQ mm 600X1,000X222 600X1,000X222 600X1,140X222 600X1,140X222 600X1,420X222 600X1,420X222
Piping
12.7 15.9 15.9 (HXWXD)
connections Gas (Flare) FXNQ 610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220
Drain VP20 (External Dia, 26/Internal Dia, 20) FXLQ kg 25 25 30 30 36 36
Machine weight
FXNQ 19 19 23 23 27 27
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5
Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9
Wall Mounted Type Drain 21O.D.

Note: Specifications are based on the following conditions;


MODEL FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE •Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Power supply 1-phase, 220 -240/220V, 50 Hz •Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Cooling capacity kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 6,300
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
Btu/h(*1) 7,800 9,900 12,600 16,000 19,800 24,900 During actual operation, these values are normally somewhat higher as a result of ambient conditions.

kW (*1) 2.3 2.9 3.7 4.7 5.8 7.3


(*2) 2.2 2.8 3.6 4.5 5.6 7.1
Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
kW 2.5 3.2 4.0 5.0 6.3 8.0
Casing White (3.0Y8.5/0.5)
Airflow rate (H/L) m3/min 7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14
cfm 265/159 282/177 300/194 424/318 530/424 671/494
Sound level (H/L) dB(A) 35/31 36/31 38/31 39/34 42/37 47/41
Dimensions (HXWXD) mm 290X795X238 290X795X238 290X795X238 290X1,050X238 290X1,050X238 290X1,050X238
Machine weight kg 11 11 11 14 14 14
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5
Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9
Drain VP13 (External Dia, 18/Internal Dia, 13)

Note : Specifications are based on the following conditions;


•Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
•Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

29 30
SPECIFICATIONS
Connection unit series indoor units
OUTDOOR UNITS
* A type of BEV unit is necessary for each Connection unit series indoor unit.
* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other
series, cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units.
Cooling Only
However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating MODEL RXMQ4PVE RXMQ5PVE RXMQ6PVE
switchover will be possible.
* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable Power supply 1-phase, 220-230 V, 50 Hz/220 V
cooling/heating switchover. Kcal/h 9,600 12,000 13,300
* Group control between Connection Unit series equipment within one system is possible. However, group control with the other Cooling capacity Btu/h 38,200 47,700 52,900
VRV indoor units is not possible. kW 11.2 14.0 15.5
Power consumption kW 2.95 3.97 4.44
Capacity control % 24 to 100

Ceiling Suspended Cassette Type (50 Hz only) Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor
Motor output kW 2.5 3.0 3.5
Indoor unit FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1
MODEL Airflow rate m /min 106
3

Connection unit BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE Dimensions (H x W x D) mm 1,345 x 900 x 320


Power supply 1-phase, 220-240 V, 50 Hz Machine weight kg 125
Kcal/h(*1) 7,100 10,000 12,500 Sound level dB(A) 50 51 53
Btu/h(*1) 28,300 39,600 49,500 Operation range CDB -5 to 46
Cooling capacity
(*1) 8.3 11.6 14.5 Type R-410A
kW Refrigerant
(*2) 8.0 11.2 14.0 Charge kg 4.0
Kcal/h 7,700 10,800 12,000 Piping Liquid ° 9.5 (Flare)
mm
Heating capacity (Max.) Btu/h 30,700 42,700 47,800 connections Gas ° 15.9 (Flare) ° 19.1 (Brazing)
kW 9.0 12.5 14.0
Casing White(10Y9/0.5)
m /min
3
19/14 29/21 32/23 Heat Pump
Indoor unit

Airflow rate (H/L)


cfm 671/494 1,024/741 1,130/812
MODEL RXYMQ4PVE RXYMQ5PVE RXYMQ6PVE
Sound level (H/L) 230 V dB(A) 40/35 43/38 44/39
Power supply 1-phase, 220-230 V, 50 Hz/220 V
Dimensions (HXWXD) mm 165X895X895 230X895X895 230X895X895
Machine weight kg 25 31 31
Kcal/h 9,600 12,000 13,300
Cooling capacity Btu/h 38,200 47,800 52,900
Liquid 9.5 (Flare)
Piping
Gas mm 15.9 (Flare) kW 11.2 14.0 15.5
connections
Drain VP 20 (External Dia. 26/Internal Dia. 20) Kcal/h 10,800 13,800 15,500
Note: Specifications are based on the following conditions;
Heating capacity Btu/h 42,700 54,600 61,400
•Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
kW 12.5 16.0 18.0
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Power Cooling 2.95 3.97 4.44
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. kW
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. consumption Heating 3.27 4.09 4.82
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacity control % 24 to 100
Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor
Motor output kW 2.5 3.0 3.5
Airflow rate m /min 106
3

Dimensions (H x W x D) mm 1,345 x 900 x 320


Machine weight kg 125
Sound level (Cooling/Heating) dB(A) 50/52 51/53 53/55
Operation Cooling CDB -5 to 46
range Heating CWB -20 to 15.5
Type R-410A
Refrigerant
Charge kg 4.0
Piping Liquid ° 9.5 (Flare)
mm
connections Gas ° 15.9 (Flare) ° 19.1 (Brazing)
Note: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During
actual operation, these values are normally somewhat higher as a result of ambient conditions.
• Refrigerant charge is required.

31 32
OPTION LIST
INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Duct Type
No. Type FXFQ25L FXFQ32L FXFQ40L FXFQ50L FXFQ63L FXFQ80L FXFQ100L FXFQ125L No. Type FXMQ20P FXMQ50P FXMQ100P
Item Item FXMQ25P FXMQ40P FXMQ63P FXMQ125P
1 Decoration Panel BYCP125K-W1 FXMQ32P FXMQ80P FXMQ140P
2 Sealing member of air discharge outlet KDBH55K160F 65% KAF372AA36 KAF372AA56 KAF372AA80 KAF372AA160
3 Panel spacer KDBP55H160FA 1 High efficiency filter
90% KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160
High efficiency filter unit 65% KAFP556B80 KAFP556B160
2 Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160
High efficiency filter unit 90% KAFP557B80 KAFP557B160
Replacement high efficiency filter 65% KAFP552B80 KAFP552B160 3 Long life replacement filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160
Replacement high efficiency filter 90% KAFP553B80 KAFP553B160 4 Long life filter chamber kit KAF375AA36 KAF375AA56 KAF375AA80 KAF375AA160
4 Filter related
Filter chamber KDDFP55B160 White KTBJ25K36W KTB25KA56W KTB25KA80W KTB25KA160W
Long life replacement filter Non-woven type KAFP551K160 5 Service panel Fresh white KTBJ25K36F KTBJ25K56F KTBJ25K80F KTBJ25K160F
Ultra long-life filter KAFP55B160
Replacement ultra long-life filter KAFP55H160H Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T
Without T shape and fan KDDP55B160 6 Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
Chamber type
5 Fresh air intake kit With T shape without fan KDDP55B160K
Direct installation type KDDP55X160
6 Branch duct chamber KDJP55B80 KDJP55B160 Ceiling Suspended Type
7 Chamber connection kit KKSJ55KA160
No. Type FXHQ32MA FXHQ63MA FXHQ100MA
8 Insulation kit for high humidity KDTP55K80 KDTP55K160 Item
1 Drain pump kit KDU50N60VE KDU50N125VE
2 Replacement long-life filter (Resin net) KAF501DA56 KAF501DA80 KAF501DA112
Ceiling Mounted Cassette (Compact Multi Flow) Type 3 L-type piping kit (for upward direction) KHFP5MA63 KHFP5MA160
No. Item Type FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M
1 Decoration panel BYFQ60B8W1
2 Sealing member of air discharge outlet KDBH44BA60 Wall Mounted Type
3 Panel spacer KDBQ44BA60A No. Type FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P
Replacement long-life filter KAFQ441BA60
Item
4
1 Drain pump kit K-KDU572EVE
5 Fresh air intake kit Direct installation type KDDQ44XA60

Ceiling Mounted Cassette (Double Flow) Type Floor Standing Type


Type FXCQ20M Type FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA
No. FXCQ25M FXCQ40M FXCQ50M FXCQ63M FXCQ80M FXCQ125M No. Item
Item FXCQ32M
1 Decoration Panel BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1 1 Long life replacement filter KAFJ361K28 KAFJ361K45 KAFJ361K71
High efficiency filter 65% 1 KAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160
High efficiency filter 90% 1 KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160
2 Filter related
Filter chamber bottom suction KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160 Concealed Floor Standing Type
Long life replacement filter KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160 Type FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA
Note: 1 Filter chamber is required if installing high efficiency filter.
No. Item
1 Long life replacement filter KAFJ361K28 KAFJ361K45 KAFJ361K71

Ceiling Mounted Cassette Corner Type


No. Type FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA
Ceiling Suspended Cassette Type
Item
Type
Decoration Panel BYK45FJW1 BYK71FJW1 No. Item FXUQ71MA FXUQ100MA FXUQ125MA
1 Panel related
Panel Spacer KPBJ52F56W KPBJ52F80W
1 Replacement long-life filter KAF495FA140
Long life replacement filter KAFJ521F56 KAFJ521F80 2 Sealing member of air discharge outlet (*1) KDBH49FA80 KDBH49FA140
Air inlet and air
Air discharge grille K-HV7AW K-HV9AW 3 Decoration panel for air discharge KDBT49FA80 KDBT49FA140
2 discharge outlet
Air discharge blind panel KDBJ52F56W KDBJ52F80W 4 Vertical flap kit KDGJ49FA80 KDGJ49FA140
related
Flexible duct (with shutter) KFDJ52FA56 KFDJ52FA80 5 L-shape piping kit KHFP49MA140
Note: (*1): This option is necessary for setting up 2-way (opposing directional) airflow when the air conditioner is installed.

Slim Ceiling Mounted Duct Type (700 mm width type)


No. Item Type FXDQ20PB FXDQ25PB FXDQ32PB
1 Insulation kit for high humidity KDT25N32

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)


Type
No. Item FXDQ40NB FXDQ50NB FXDQ63NB
1 Insulation kit for high humidity KDT25N50 KDT25N63

33 34
OPTION LIST
OUTDOOR UNITS CONTROL SYSTEMS
Cooling only System Configuration
No. Type RXMQ4P RXMQ5P RXMQ6P No. Item Model No. Function
Item
1 Cool/Heat Selector KRC19-26A 1 Residential central remote controller Note 3 •Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF,
DCS303A51 temperature settings and scheduling can be controlled individually for indoor units.

1-1 Fixing Box KJB111A 2 Central remote controller Note 2


DCS302CA61 •Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and
2 REFNET Header KHRP26M22H (Max. 4 branch) 2-1 Electrical box with earth terminal (3 blocks) KJB311AA
monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one
system.

KHRP26M33H (Max. 8 branch)


3 Unified ON/OFF controller Note 2
DCS301BA61
3 REFNET Joint KHRP26A22T
3-1 Electrical box with earth terminal (2 blocks) KJB212AA
•Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and
4 Central drain plug KKPJ5F180 operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.
3-2 Noise filter (for electromagnetic interface use only) KEK26-1A
5 Fixture for preventing overturning KPT-60B160

6 Wire fixture for preventing overturning K-KYZP15C 4 Schedule timer Note 2 •Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units
DST301BA61 (128 units). Can turn units ON/OFF twice per day.

5 Interface adaptor for SkyAir-series For SkyAir, FD(Y)M-FA, FDY-KA DTA102A52 •Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET
FDYB-KA, FVY(P)J-A, FXUQ-MA communication system adopted for the VRV System.

Heat pump 6 Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55


* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be
controlled.

No. Type RXYMQ4P RXYMQ5P RXYMQ6P


Item 7 Wiring adaptor for other air-conditioner DTA103A51
1 Cool/Heat Selector KRC19-26A
8 D -NET DTA109A51 •Up to 1024 units can be centrally controlled in 64 different groups.
1-1 Fixing Box KJB111A Expander Adaptor •Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of branches: 16)
apply to each adaptor.

2 Cool/Heat Selector KHRP26M22H (Max. 4 branch) 8-1 Mounting plate KRP4A92 •Fixing plate for DTA109A51

KHRP26M33H (Max. 8 branch)


Notes: 1. Installation box for adaptor must be obtained locally.
2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary.
3 REFNET Joint KHRP26A22T 3. For residential use only. Cannot be used with other centralised control equipment.

4 Central drain plug KKPJ5F180

5 Fixture for preventing overturning KPT-60B160

6 Wire fixture for preventing overturning K-KYZP15C


Building Management System
No. Item Model No. Function
1 intelligent Touch Basic Hardware intelligent Touch Controller DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Controller

CONTROL SYSTEMS
1-1 Option Hardware DIII-NET plus adaptor DCS601A52 •Additional 64 groups (10 outside units) is possible.

1-2 Electrical box with earth terminal (4 blocks) KJB411A •Wall embedded switch box.

Operation Control System Optional Accessories 2 intelligent Touch Basic Hardware intelligent Touch Manager DCM601A51 •Air-conditioning management system that can be controlled by touch screen.
Manager
No. Type FXFQ-L FXZQ-M FXCQ-M FXKQ-MA FXDQ-PB FXMQ-L FXHQ-MA FXAQ-L FXLQ-MA FXUQ-MA
FXDQ-NB FXNQ-MA
Item 2-1 Option Hardware iTM plus adaptor DCM601A52 •Additional 64 groups (10 outdoor units) is possible.
Max. 7 iTM plus adaptors can be connected to intelligent Touch Manager.
1 Remote controller Wireless C/O BRC7F635F BRC7E531W BRC7C67 BRC4C63 BRC4C66 BRC4C66 BRC7EA66 BRC7EA619 BRC4C64 BRC7CA529W
2-2 iTM integrator DCM601A53 •Max. 5 intelligent Touch Managers can be integrated.
H/P BRC7F634F BRC7E530W BRC7C62 BRC4C61 BRC4C65 BRC4C65 BRC7EA63W BRC7EA618 BRC4C62 BRC7CA528W
2-3 Software iTM power proportional DCM002A51 •Power consumption of indoor units are calculated based on operation status of the indoor unit and
Wired BRC1C62 distribution outside unit power consumption measured by kWh metre.

2 Navigation remote controller (Wired remote controller) BRC1E61 2-4 iTM energy navigator DCM008A51 •Building energy consumption is visualised.
Wasted air-conditioning energy can be found out.

3 Wired remote controller with weekly schedule timer BRC1D61 2-5 Di unit DEC101A51 •8 pairs based on a pair of On/Off input and abnormality input.

4 Simplified remote controller (Exposed type) — BRC2C51 — BRC2C51 —


2-6 Dio unit DEC102A51 •4 pairs based on a pair of On/Off input and abnormality input.

5 Remote controller for hotel use (Concealed type) — BRC3A61 — BRC3A61 —


3 *1 Interface for use in BACnet ®
DMS502B51 •Interface unit to allow communications between VRV and BMS. Operation and monitoring of
air-conditioning systems through BACnet® communication.
6 Adaptor for wiring KRP1C63 KRP1BA57 KRP1B61 KRP1B61 KRP1B56 KRP1C64 KRP1BA54 — KRP1B61 —
3-1 Optional DIII board DAM411B51 •Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable
7-1 Wiring adaptor for electrical appendices (1) KRP2A62 KRP2A62 KRP2A61 KRP2A61 KRP2A53 KRP2A61 KRP2A62 KRP2A61 KRP2A61 — independently.
Communication
3-2 line Optional Di board DAM412B51 •Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable
7-2 Wiring adaptor for electrical appendices (2) KRP4AA53 KRP4AA53 KRP4AA51 KRP4AA51 KRP4A54 KRP4AA51 KRP4AA52 KRP4AA51 KRP4AA51 KRP4AA53 independently.

8 Remote sensor (for indoor temperature) KRCS01-4B KRCS01-1B KRCS01-4B KRCS01-1B 4 *2 Interface for use in LONWORKS ®
DMS504B51 •Interface unit to allow communications between VRV and BMS. Operation and monitoring of
air-conditioning systems through LONWORKS communication.
®

9 Installation box for adaptor PCB Note 2,3 Note 4.6 Note 2,3
— Note 4,6 Note 2,3 Note 3 Note 2,3
— KRP1BA97 5 Contact/analogue Unification adaptor for DCS302A52 •Interface between the central monitoring board and central control units.
KRP1H98 KRP1BA101 KRP1B96 KRP1BA101 KRP4A96 KRP1CA93 KRP4AA93 computerised control
signal
10 External control adaptor for outdoor unit DTA104A62 DTA104A62 DTA104A61 DTA104A61 DTA104A53 DTA104A61 DTA104A62 DTA104A61 DTA104A61 —
Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
®

*2. LONWORKS is a trademark of Echelon Corporation registered in the United States and other countries.
®

11 Adaptor for multi tenant DTA114A61 — DTA114A61 — DTA114A61 — *3. Installation box for adaptor must be obtained locally.

Note: 1. Installation box is necessary for each adaptor marked . 3. Only one installation box can be installed for each indoor unit. 5. Installation box is necessary for second adaptor.
2. Up to 2 adaptors can be fixed for each installation box. 4. Up to 2 installation boxes can be installed for each indoor unit. 6. Installation box is necessary for each adaptor.

35 36
MEMO