Hoesch Bogendach
Striking Architecture
A roof system which meets ■ Functional
all requirements in relation to Thanks to its excellent
high functional quality and structural characteristics,
good style. For a new form of the Hoesch Arched Roof
architecture - full of swing. can also be used as a free-
span structure. In the
■ Aesthetics double-shell design, up to
The Hoesch Arched Roof 20 m can be freely span-
gives architects, planners ned, and the Arched Roof
and building owners the acts as a supporting frame-
possibility of creating mo- work and roofing at the
dern, high-tech buildings same time. A very low con-
with new, trend-setting struction weight and a gain
aesthetics - there are no in additional useful area are
pleats to spoil the visual economic benefits.
appeal of the arch, the eye
follows, without disturban- ■ Well protected
ce, the elegant lines of the Coil galvanized strip and a
curved profile.

With a range of curved profiles,


coloured plastic coating
give safe protection against
corrosion and ensure a long
SpecialLine
different radii and a large choi-
service life. Select your pre-
ce of colours, this roof system
ferred colour from a large
gives plenty of scope for new
range.
ideas and opens up new paths
for versatility of design.

GB · Info 3.7.1 · 8.2007 · bc


Versatility
Hoesch Arched Roof is suited for
a wide range of applications:
■ production plants
■ warehouses
■ fair and exhibition halls
■ leisure centres
■ sports centres
■ grandstand roofings
■ administration buildings
■ schools
■ roofs for platforms and
parking areas
GB · Info 3.7.1 · 8.2007 · bc

3
Close co-operation between ThyssenKrupp Hoesch Bau-
First Service the various members of the systeme - the competent part-
Hoesch Group involved in ner for building owners, plan-
material and production ners and architects. Common
technology form the basis of planning right from the start
products which meet the allow us to produce tailor-
most exacting demands with made solutions for our custo-
respect to properties and mers. Based on a perfect co-
design. Our customers ordination of service and pro-
benefit from interdisciplinary duction, we offer quality and
know-how and internal reliability from advice to
synergies. supply to erection. First Class
Service.

GB · Info 3.7.1 · 8.2007 · bc

4
Technique

■ Individual solutions ■ Variable


Planning and engineering The Hoesch Arched Roof sheets have a load-bearing
can be carried out to suit can be used as a single or function. The thermal insu-
all the requirements of our double-shell roofing sys- lation between the two
customers. For an optimum tem. The single-shell versi- sheets will serve as sound
result, the various trades on can serve as a support- insulation, if required.
are co-ordinated as soon ing framework or as a non-
as in the early planning insulated roof skin. In the
stage. double-shell version, both

■ Extendable ■ Stable
With a large variety of flash- The arched elements are not and HP 107 B are available.
ings and various lighting folded but produced using a ThyssenKrupp Bausysteme
systems, the Hoesch Arched roll-bending technique which will be pleased to prepare
Roof may be designed to is patented world wide. This calculations so as to optimi-
meet specific requirements special production method se material thickness, basic
precisely. This roof system makes the arched roof extre- weight and profiling.
may be combined with other mely stable and allows the
components and structural large spans.
parts from the extensive Depending on the require-
ThyssenKrupp Bausysteme ments on the structure and
programme. the design, profiles HP 41 B
GB · Info 3.7.1 · 8.2007 · bc

5
Hoesch Arched Roof

The ThyssenKrupp Bau-


systeme service is available
right from the beginning. After
receipt of your enquiry, our
calculation software allows for
a swift preliminary design and
structural analysis, taking
account of the loads which
must be accommodated by the
supporting structure.

6
7
Hoesch Arched Roof ThyssenKrupp Bausysteme

Technical information

Principle: Hoesch arched profiles


Metallic roofing on a curved
structure provided by others or
a freely spanned arch without
any additional supporting
structure between the end
supports (load-bearing capacity
of the arch).

Material:
Arched trapezoidal zinc-coated
steel sections which are not
folded but produced using a
roll-bending technique.

Protection against corrosion:


Coil-coating with a choice from Arch dimensions
a range of various colour
shades.
B
Fixing technique:
Approved stainless steel fas-
teners or special connectors in
the area of the supports.

Application:
As roofing or as a freely span-
ned arch, designed as non-
R
H

insulated single shell or as


insulated double shell with S = Chord length
S R = Arch radius
span widths up to 20 m.
H = Rise (height)
B = Arch length

Double-skin design

t
s hee
ter
Ou

Hat pro t
Therm file ee
al ins
ulatio sh
n
er
Inn

GB · Info 3.7.1 · 8.2007 · bc

Supp
ort
Clam
ping
plate

8
Hoesch Arched Roof ThyssenKrupp Bausysteme

Hoesch Arched Roof HP 41 B Selection of the profile:


Selection of the appropriate
Use as outer or inner arched skin
profile depends on the required
radius of the arch as well as on
110 50 50
the span and the expected
38

t
B
load.
A
160 110 50
ThyssenKrupp Bausysteme
Cover width 960 offer the following services:

max. arch length: 16 m1) Preliminary design using our


calculation software for structu-
Designation of building part Material thickness t Arch radius Dead weight ral analysis which leads to the
mm m kg/m2
selection of the most cost-
HP 41 B 0.75 ≥ 8.00 7.81 effective profile.
0.88 ≥ 6.00 9.17
1.00 ≥ 4.50 10.42 The best results in terms of
1.25 ≥ 4.00 13.02 structural analysis are achieved
1.50 ≥ 4.00 15.63 when the dimensions of the
1)
Arch length up to 18 m on request span and the radius of the arch
are identical.

Hoesch Arched Roof HP 107 B


Use as outer or inner arched skin with larger dimensions

179 71 71
t

B
106

250 179 71

Cover width 750

max. arch length: 24 m


max. arch radius: 35 m
Designation of building part Material thickness t Arch radius Dead weight
mm m kg/m2

HP 107 B 0.75 ≥ 30.00 10.00


0.88 ≥ 22.00 11.73
1.00 ≥ 13.00 13.33
1.25 ≥ 11.00 16.67
1.50 ≥ 10.00 20.00
GB · Info 3.7.1 · 8.2007 · bc

9
Hoesch Arched Roof ThyssenKrupp Bausysteme

Technical information

Supports Eaves design (steel)


If the Hoesch Arched Roof is
freely spanned, no purlins or
trusses are required. The arch Outer skin
may be supported by a struc-
Thermal insulation
ture of steel, reinforced con-
crete or wood. The horizontal Hat profile
support pressures are either
transmitted into the rigid
supporting structure or addi- Profile filler
tional tiebacks are provided. Inner skin
Profile filler
Clamping plate

Tieback
Closing section
Support
Angle

Arched roof on concrete floor

Hat profile

Thermal insulation Outer skin

Profile filler

Inner skin
Clamping plate

Foot angle
Anchor rail
Closing section
Angle

Floor
GB · Info 3.7.1 · 8.2007 · bc

10
Hoesch Arched Roof ThyssenKrupp Bausysteme

Valley gutter (steel) Valley gutter design


The Hoesch Arched Roof may
be designed as a single-bay or
Outer skin
multi-bay roof. Higher loads
Heat insulation
arising from snow accumula-
Profile filler
Capping profile tion must be taken into
account.
Closing section

Inner skin
Clamping plate

Tieback
Gutter-bearing
girder
(steel gutter)
Foil lining

Heat insulation
(non-crush)
Overflow

Valley gutter (reinfored concrete)

Outer skin

Hat profile
Heat insulation Overflow

Inner gutter

Tieback

Inner skin

Support

Gutter-bearing
girder
(reinforced concrete)
GB · Info 3.7.1 · 8.2007 · bc

11
Hoesch Arched Roof ThyssenKrupp Bausysteme

Technical information

Verge design Verge design


Connecting flashings, e.g.
barge boards, are available as
Thermal insulation Outer skin Verge profile, bent
standard flashings for various
arch radii.

Load transmission from the


gable walls into the skins of
the arched roof requires a
separate structural analysis.

Inner skin Hat profile

Edge girder, bent

Thermowand

Cantilevered verge detail

Verge profile, bent Thermal insulation Outer skin

Hat profile
possible
movement Inner skin
GB · Info 3.7.1 · 8.2007 · bc

Note: supporting structure in cantilever design


12
Hoesch Arched Roof ThyssenKrupp Bausysteme

Domelight installation Lighting


Various alternatives such as
integrated transparent panels,
Framing framings for domelights,
smoke and heat outlet sys-
Sealing tape tems and ventilation fans are
available.
Bordering
profile Domelights can only be in-
Squared timber stalled in the top of the roof.
LA. = 1200/1800/2400
Integrated transparent panels
consist of bent panels which
are installed in the span direc-
tion of the arch.

The width of these panels


and domelights is limited to
1,200 mm.

Distance between dome-


lights and transparent panels
≥ 5,000 mm.

A structural analysis is required


in any case, joint beams must
Integrated transparent panels be provided as required.

Outer skin Bent transparent panels

1200
Inner skin
Bordering profile Square tube
GB · Info 3.7.1 · 8.2007 · bc

13
Hoesch Arched Roof ThyssenKrupp Bausysteme

Accessories

Domelight installation Part no. Designation

S 35 - 033 Clamping plate, galvanised


for profile HP 41 B

S 35 - 034 Clamping plate, galvanised,


painted for profile HP 41 B

S 35 - 035 Clamping plate, galvanised


for profile HP 107 B

S 35 - 036 Clamping plate, galvanised,


painted for profile HP 107 B

S 35 - 044 Profile filler, 30 mm wide


for profile HP 41 B

S 35 - 045 Profile filler, 50 mm wide


for profile HP 41 B

S 35 - 046 Profile filler, 30 mm wide


for profile HP 107 B

S 35 - 047 Profile filler, 50 mm wide


for profile HP 107 B

S 35 - 021 Verge flashing,


bent
girth 340
length: 6000 mm

S 35 - 022 Verge flashing,


bent
girth 440
length: 6000 mm

S 35 - 023 Verge flashing,


bent
girth 540
length: 6000 mm

Hat profile,
S 35 - 011 material thickness 1.00 mm
S 35 - 012 material thickness 1.50 mm
S 35 - 013 material thickness 2.00 mm
GB · Info 3.7.1 · 8.2007 · bc

length: 6000 mm

14
GB · Info 3.7.1 · 8.2007 · bc

15
Fax:
Hammerstrasse 11

Internet: www.tks-bau.com
D-57223 Kreuztal, Germany

+49 / 27 32 / 599 1 219


Phone: +49 / 27 32 / 599 1 221
TK Bausysteme GmbH

E-Mail: export.tks-bau@thyssenkrupp.com
All details contained in this brochure are only guaranteed insofar as they have been expressly and speci-
fically confirmed in writing. Subject to technical modifications.
GB • Info 3.7.1 • 8.2007 • bc

You might also like