You are on page 1of 20

Program Release Information

CSES ID-No. DLBT1600291EN


Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
1. Release version and download file name

The newly released program version and download file name is as follows.

[Release version]
<75BW-5(e) Series MFP firmware>
Model Program Name Current Ver. New Ver. Program File Name Note
75BW-5(e) Series MFP firmware G20-K7 G20-K8 A55V0Y0-F000-G20-K8.exe

[Download File Name]

A55V0Y0-F000-G20-K8.exe

PRI_75BW-5(e)_Series_DLBT1600291EN_0.doc

2. What changed

2.1. Release of 75BW-5(e) Series (Maintenance Release Program Function Version7 Ver. G20-K8)

The individual files and the checksum are as follows.

Program Name File Name Checksum Note

MFP Card Version A55V0Y0-F000-G20-K8

MFP Controller BOOT Program A55V0Y0-1E00-G00-10 0313

Linux-based MFP Controller Linux-2.6.26.8-rt16 6131

MFP Controller Kernel Program A55V0Y0-1C00-G00-66 BC6F

MFP Controller Subset A55V0Y0-1F00-G00-72 40A9

MFP Controller A55V0Y0-0100-G20-K8 7579

MFP Controller System A55V0Y0-1000-G20-K8

MFP Controller Print Controller A55V0Y0-3000-G01-46

MFP Controller Print Controller Font A55V0Y0-3F00-G01-40

MFP Controller Print Controller Demo A55V0Y0-3E00-G00-81

Page

MFP Controller MIO A55V0Y0-5000-G00-S4

MFP Controller PIC A55V0Y0-8200-G00-52

MFP Controller Thread Image Parameter A55V0Y0-8B00-G00-10 0423 old CCD

MFP Controller Thread Image Parameter A55V0Y0-8B01-G00-10 0424 new CCD

MFP Controller PIC Image Parameter A55V0Y0-8A00-G00-12 0484 old CCD

MFP Controller PIC Image Parameter A55V0Y0-8A01-G00-12 0485 new CCD

Scanner A55V0Y0-0023-G00-13 1B24 old CCD

Konica Minolta Confidential 1/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
Scanner A55V0Y0-0023-G91-13 9977 new CCD

Printer A55V0Y0-0050-G00-75 1F18

FAX board controller A22M0Y0-4000-G00-11 9EAF

Operation panel message data A55V0Y0-8100-G00-K8 8479

ADF A3CK0Y0-0024-G00-04 864D

Finisher (FS-534) A3EP0Y0-0071-G10-03 8170

Finisher (FS-535) A2Y10Y0-00N1-G00-26 5596

Finisher (JS-602) --- ---

RU A2Y10Y0-00R1-G00-07 6900

ZU A1090Y0-00H1-G01-12 C49E

SD A3ER0Y0-0071-G00-08 D58E

COPY PROTECT --- 5D5B

Movie Data A55V0Y0-C000-G00-00

Voice Data A55V0Y0-C100-G00-55

Panel Sound Data A55V0Y0-C200-G00-00 40E1

Dictionary Data A2X0010-B100-G00-02

Engine Parameter A55V0Y0-0054-G00-00

2.2. Fixed issues

2.2.1. Addition of function/ Change of specifications

1. TLS1.1/1.2 is supported.

2. When APP key and Group key are inactive, hide these key icons.

SoftSwitch No.223

HEX Assignment 00 : This modification is not applied. (default)

HEX Assignment 01 : This modification is effective.

3. Function Version is displayed on CSRC.

4. SHA-2 is supported.

2.2.2. The following issues are solved in this firmware.

1. The data is sent to CSRC on the day different from the one configured in [Notification Setting] of CSRC.

[QUBJ_1500853070]

Konica Minolta Confidential 2/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
2. When touching "All" to select a large number of [Address Book] registered in "Group" of [Add. Type], it may take time to

complete the selection. [ERBJOS1400735887]

3. If executing proof copy on [Preview] Key by using program job, it is printed with one more extra copy.

[ERBJTK1400746822]

4. If printing PC Print job with 1200dpi, MFP may hang up. [ERBJTS1400735064]

5. When a specific PDF file is printed from USB, C-E301 occurs. [ERBJKG1400773491]

6. C-FA14 (Detail code: 0x07FF) may occur. [ERBJHK1400758587]

7. When using vendor, the change doesn't return if printing the job from USB memory and the job is paused and then

restarted. [ERBJKS1400776212]

8. When sending FAX job, T-13 error may occur and the same document is sent several times to the destination.

[ERBJKG1400751362]

The following Software Switch is added for this issue.

Software Switch No. : 108

HEX Assignment 00 : This modification is not applied. (default)

HEX Assignment 01 : This modification is effective.

9. C-E301 may occur when Machine Management List is saved in USB memory. [ERBJOS1400772306]

10. When printing a large volume of jobs by using standard controller with Fiery, the following symptoms may occur.

[ERBJTS1400776228]

- It takes time to complete printing.

- The panel is slow to respond.

11. The copy reservation can not be available if trying to perform the copy reservation of the program job again while the

program job is printed out. [ERBJTS1500802272]

12. C-E301 may occur if connecting from PSBO. [PEBJOS1300677617]

13. C-E301 (0xC135) occurs if the Excel file with long file name is printed. [ERBJOS1500807456]

14. If obtaining Authentication and Address information from MFP by Page Scope Data Administrator, Authentication

information error User may occur. [ERBJOS1400789093]

15. When the debug log acquiring system is enabled, the Trouble Code C-E301 (detail codes:0xC01D) may occur.

[ERBJTK1500804281]

16. The adjustment rotating setting of searchable PDF is canceled after Scan-sending, and it cannot be selected again.

[ERBJNG1500829829]

17. If pushing [<-] button after entering FAX address by direct input, the last entered number disappears.

[ERBJKS1500835946]

18. On CU-1 connected environment, the following keys and hard keys on Control Panel don't respond. [ERBJKG1500831066]

- Menu/Enlarge Display/Guidance/Access/Interrupt/Preview

19. SmartSESAME screen may be locked. [ERBJ__1500841219]

Konica Minolta Confidential 3/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
20. The registered settings is not reflected even if using scan program. [ERBJOS1500841526]

21. When the TX Operation Log function is valid, MFP may hang up. [ERBJOS1500825859]

22. After returning from low power mode, a warning screen "Turn on the device" of IC-414 is displayed and the screen cannot

be operated temporarily. [ERBJTK1500841234]

23. C-E301 and others occur if documents of two pages or more are copied/scanned/received when the file type of an image

log is set to "compact PDF". [ERBJSL1500853057]

24. If a document is selected and [Start] button is pressed on Server-less Pull Printing document list screen, Job is deleted by

"Auto delete" error. [ERBJOS1500846526]

25. When using LK-114 (ubiquitous print), if deleting the saved jobs which have been deleted earlier again, the MFP does not

enter Power Save mode even pressing the Power Switch. [ERBJKG1400766843]

26. C-E301 (0xC2C3) occurs when a mixed original is scanned by using Searchable PDF function. [ERBJKG1500803771]
27. If a PS file created by the printer driver for Mac is printed multiple times, jobs may be printed to the different tray from the

selected tray by the printer driver. [ERBDFS1400736657]

28. IEEE802.1X does not work when using PEAP-MS-CHAPv2. [ERBDSP1500830239]

29. C-E301 (detail codes: 0xC072 or 0xC04D) may occur. [ERBDFS1500798410]

30. When PS file including "%%" on top is printed, PS code is printed. [ERBUS_1500813085]

31. When printing LK-110 E-mail RX print job, the job is stapled into the group. [ERBUS_1500809988]

32. The Trouble Code C-FC04 may occur after returning from Power Save mode.[ERBUS_1400764419, PTBUS_1400000000]

[Caution]

This problem is not solved in this firmware.

When this problem is occurred, the Trouble Code is wrong. So, the Trouble Code is changed to C-F004 on this firmware.

33. If connecting remote panel during Sleep mode, MFP will hang up. [ERBCZ_1400760220]

34. When receiving specific packets, C-E301 occurs. [IQBCZ_1400739340]

35. When scanning by compact PDF, the lines and the characters are lighter than C652 Series. [ERBCZ_1400738294]

The following Software Switch is added for this issue.

Software Switch No. : 110

HEX Assignment 00 : This modification is not applied. (default)

HEX Assignment 01 : This modification is effective.

36. When AU-205H (Omnikey5427CK) is connected, the Unconnected mark (x mark) is displayed on USB icon.

[ERBNO_1500798025]

37. When [When Pop-up Closes] of Animation Setting is [No], MFP will be hung up if a file in the box is deleted.

[ERBNZ_1500834555]

38. It may not be able to login by another card while login. [ERBEU_1500806564]

39. If printing the file from HP Output Server by using SR tool, the printing error occurs. [ERBEU_1500822615]

40. On the MFP with FS-534 is installed, paper jam occurs if 2-sided copy or print is repeated. [ERBAT_1500804329]

Konica Minolta Confidential 4/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
41. The hard key "Access" on the operation panel is called "ID" for the logout confirmation message. [QUBAU_1400745961]

42. When connecting Key Counter, only the first document will be counted if some documents are selected and printed from

Security Print Box. [ERBBE_1400775474]

43. The start time column of Date format in the activity report becomes "MM-DD (Month-Day)" even if "Europe" is selected in

marketing Area settings. [ERBF__1400782065]

44. When UK-204 is not installed, i-Option LK-111/LK-115 cannot be activated with Token Code from PSWC.

[QUIMGT1400785538]

45. Distribution control number of Stamp Repeat is darker. [ERMNLC1400776569]

The density of distribution control number can be changed either current density or similar density of Watermark by Soft

Switch.

SoftSwitch No.114
HEX Assignment 00 : This modification is not applied. (default)

HEX Assignment 01 : This modification is effective.

46. When the address book is registered by 2byte PC name, Address Book of WebConnection cannot be opened.

[ERMura1400769692]

47. The Spanish water mark is not printed. [ERDVMT1500805209]

48. The Trouble Code C-E301 (detail codes:0xC08D) may occur in using SafeQ environment. [ERBPT_1500810585,

ERBPT_1500821793]

49. When the Auto Tray Select is not selected on the Auto Tray Selection settings, C-E004 will occur if MFP is started.

[ERBJNG1400785988, ERBDSP1500797853]

50. Meter count may be reset if FW is downloaded before the recovery process that starts after using the reset tool.

51. Measurement for making IPv6 available without IPv6 router.

52. A user swipe a card for login to MFP during public user logged in, card authentication may be failed.

3. Functional restrictions

1. When the original is not set on ADF, Document set sound rings if the Document feed tray is lifted up.

2. If the document in ID&Print Box is selected while printing many ID&Print Jobs, the selected document may flicker.

3. On Mac10.2.8, printing cannot be performed with IPP.

This is due to Mac OS X. Please upgrade the OS version to 10.3.2 or later.

* Refer to the Readme.txt file which is included in each driver and application for other functional restrictions.

* Additional memory installation is required when using the following Open API function.

- Initial screen customization

Konica Minolta Confidential 5/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03

Konica Minolta Confidential 6/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4. How to install

4.1. How to install program

Use USB memory to install. For the details, see the Service Manual.

Conditions for USB memory which can be used for updating the firmware are as follows:

- Securities such as data encryption and password lock shall be released, or the security function shall be turned Off.

- Memory with 1 GB to 2 GB are recommended (One with 4 GB or more may not operate)

- Compatible with USB Version 1.0/2.0 interface

- Formatted with FAT32 type

- A USB flash memory that appears as multiple drives on a computer cannot be used.

4.2. How to upgrade/downgrade firmware


[Definition of terms]

Function Version 3: Firmware Version ver.Gxx-60 and earlier.

Function Version 3 MR (Maintenance Release) Version: Firmware for Function Version 5 Version ver.Gxx-E4.

(There are not enhancement functions of Function Version 5.) "Function

Version3" has equal functions.

Function Version 5: Firmware for Function Version 5 Version ver.Gxx-E4.

Function Version 3 MR2 (Maintenance Release2) Version: Firmware for Function Version 6 Version ver.Gxx-G9/H1/H2.

(There are not enhancement functions of Function Version 6.) "Function

Version3" has equal functions.

Function Version 5 MR (Maintenance Release) Version: Firmware for Function Version 6 Version ver.Gxx-G9/H1/H2.

(There are not enhancement functions of Function Version 6.) "Function

Version5" has equal functions.

Function Version 6: Firmware for Function Version 6 Version ver.Gxx-G9/H1/H2

Function Version 3 MR3 (Maintenance Release3) Version: Firmware for Function Version 7 Version ver.Gxx-J6/K1/K2/K5/K6/K7.

(There are not enhancement functions of Function Version 7.) "Function

Version3" has equal functions.

Function Version 5 MR2 (Maintenance Release2) Version: Firmware for Function Version 7 Version ver.Gxx-J6/K1/K2/K5/K6/K7.

(There are not enhancement functions of Function Version 7.) "Function

Version5" has equal functions.

Function Version 6 MR (Maintenance Release) Version: Firmware for Function Version 7 Version ver.Gxx-J6/K1/K2/K5/K6/K7.

(There are not enhancement functions of Function Version 7.) "Function

Version6" has equal functions.

Function Version 7: Firmware for Function Version 7 Version ver.Gxx-J6/K1/K2/K5/K6/K7/K8.

About Software Switch Settings

Konica Minolta Confidential 7/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
Switch No.: 25

HEX Assignment: 60 -> Function Version7

HEX Assignment: 50 -> Function Version6

HEX Assignment: 40 -> Function Version5

HEX Assignment: 20 -> Function Version3

[Caution]

If older than Gxx-E4 firmware is installed to MFP, Gxx-E4 or later cannot be installed by IISW.

Once Gxx-E4 or later firmware is installed by USB memory, Gxx-E4 or later can be installed by IISW.

Konica Minolta Confidential 8/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4.2.1. Upgrade

4.2.1-1. Firmware upgrading procedure from Function Version3 to Function Version3 MR3 (Maintenance Release3) Version.

1. If the Loadable Driver for Function Version3 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Install Loadable Driver for Function Version7 to MFP.

4.2.1-2. Firmware upgrading procedure from Function Version3 to Function Version7.

1. If the Voice Data/Loadable Driver for Function Version3 has been already installed, delete it in Service Mode.
2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-3. Firmware upgrading procedure from Function Version3 MR (Maintenance Release) Version to Function Version3 MR3

(Maintenance Release3) Version.

1. If the Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Install Loadable Driver for Function Version7 to MFP.

4.2.1-4. Firmware upgrading procedure from Function Version3 MR (Maintenance Release) Version to Function Version7.

1. If the Voice Data for Function Version3/Loadable Driver for Function Version5 has been already installed, delete it in

Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

Konica Minolta Confidential 9/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-5. Firmware upgrading procedure from Function Version5 to Function Version5 MR2 (Maintenance Release2) Version.

1. If the Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Install Loadable Driver for Function Version7 to MFP.

4.2.1-6. Firmware upgrading procedure from Function Version5 to Function Version7.

1. If the Voice Data/Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-7. Firmware upgrading procedure from Function Version3 MR2 (Maintenance Release2) Version to Function Version3

MR3 (Maintenance Release3) Version.

1. If the Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

Konica Minolta Confidential 10/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4. Install Loadable Driver for Function Version7 to MFP.

4.2.1-8. Firmware upgrading procedure from Function Version3 MR2 (Maintenance Release2) Version to Function Version7.

1. If the Voice Data for Function Version3/Loadable Driver for Function Version5 has been already installed, delete it in

Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60
5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-9. Firmware upgrading procedure from Function Version3 MR3 (Maintenance Release3) Version to Function Version7.

1. If the Voice Data for Function Version3 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

3. Turn OFF/ON the main switch.

4. Install Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-10. Firmware upgrading procedure from Function Version5 MR (Maintenance Release to Function Version5 MR2

(Maintenance Release2) Version.

1. If the Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Install Loadable Driver for Function Version7 to MFP.

Konica Minolta Confidential 11/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4.2.1-11. Firmware upgrading procedure from Function Version5 MR (Maintenance Release) Version to Function Version7.

1. If the Voice Data//Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.
Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-12. Firmware upgrading procedure from Function Version5 MR2 (Maintenance Release2) Version to Function Version7.

1. If the Voice Data for Function Version5 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

3. Turn OFF/ON the main switch.

4. Install Voice Data for Function Version7 to MFP.

Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version7.

Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the

Applications.

4.2.1-13. Firmware upgrading procedure from Function Version6 to Function Version6 MR (Maintenance Release) Version.

1. If the Loadable Driver for Function Version5 has been already installed, delete it in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Install Loadable Driver for Function Version7 to MFP.

4.2.1-14. Firmware upgrading procedure from Function Version6 to Function Version7.

1. If the Loadable Driver for Function Version5 and the Voice Data for Function Version6 have been already installed, delete it

Konica Minolta Confidential 12/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
in Service Mode.

2. Install the Firmware for Function Version7 to MFP.

3. Turn OFF/ON the main switch.

4. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

5. Turn OFF/ON the main switch.

6. Install Loadable Driver and Voice Data for Function Version7 to MFP.

4.2.1-15. Firmware upgrading procedure from Function Version6 MR (Maintenance Release) Version to Function Version7.

1. If the Voice Data for Function Version6 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 60

3. Turn OFF/ON the main switch.

4. Install Voice Data for Function Version7 to MFP.

4.2.2. Downgrade

4.2.2-1. Firmware downgrading procedure from Function Version7 to Function Version3.

1. If the Voice Data and the Loadable Driver for Function Version7 have been already installed, delete them in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 20

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version3 to MFP.

5. Turn OFF/ON the main switch.

6. Install Voice Data/Loadable Driver for Function Version3 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-2. Firmware downgrading procedure from Function Version7 to Function Version3 MR (Maintenance Release) Version.

1. If the Voice Data and the Loadable Driver for Function Version7 have been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Konica Minolta Confidential 13/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
Switch No.: 25

HEX Assignment: 20

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version5 to MFP.

5. Turn OFF/ON the main switch.

6. Install Voice Data for Function Version3 and Loadable Driver for Function Version5 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-3. Firmware downgrading procedure from Function Version7 to Function Version5.

1. If the Voice Data and the Loadable Driver for Function Version7 have been already installed, delete it in Service Mode.
2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 40

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version5 to MFP.

5. Turn OFF/ON the main switch.

6. Install Voice Data/Loadable Driver for Function Version5 and to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-4. Firmware downgrading procedure from Function Version7 to Function Version3 MR2 (Maintenance Release2) Version.

1. If the Voice Data and the Loadable Driver for Function Version7 have been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 20

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version6 to MFP.

5. Turn OFF/ON the main switch.

6. Install Voice Data for Function Version3 and Loadable Driver for Function Version5 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-5. Firmware downgrading procedure from Function Version7 to Function Version5 MR (Maintenance Release) Version.

1. If the Voice Data and the Loadable Driver for Function Version7 have been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Konica Minolta Confidential 14/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
Switch No.: 25

HEX Assignment: 40

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version6 to MFP.

5. Turn OFF/ON the main switch.

6. Install Voice Data/Loadable Driver for Function Version5 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-6. Firmware downgrading procedure from Function Version7 to Function Version6.

1. If the Loadable Driver and the Voice Data for Function Version7 has been already installed, delete it in Service Mode.
2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 50

3. Turn OFF/ON the main switch.

4. Install the Firmware for Function Version6 to MFP.

5. Turn OFF/ON the main switch.

6. Install Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-7. Firmware downgrading procedure from Function Version7 to Function Version3 MR3 (Maintenance Release3) Version.

1. If the Voice Data for Function Version7 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 20

3. Turn OFF/ON the main switch.

4. Install Voice Data for Function Version3 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-8. Firmware downgrading procedure from Function Version7 to Function Version5 MR2 (Maintenance Release2) Version.

1. If the Voice Data for Function Version7 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 40

Konica Minolta Confidential 15/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
3. Turn OFF/ON the main switch.

4. Install Voice Data for Function Version5 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

4.2.2-9. Firmware downgrading procedure from Function Version7 to Version6 MR (Maintenance Release) Version.

1. If the Voice Data for Function Version7 has been already installed, delete it in Service Mode.

2. Change Software Switch Setting to the following in Service Mode.

Switch No.: 25

HEX Assignment: 50

3. Turn OFF/ON the main switch.


4. Install Voice Data for Function Version6 to MFP.

Attention: You cannot use the Addition of function/ Change of specifications.

Konica Minolta Confidential 16/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
4.3. How to check card version

[ROM version]:

You can check the ROM version in service mode, "Firmware Version"

For the details, see the Service Manual.

4.4. How to install movie data

Use USB memory to install. For the details, see the Service Manual.

4.5. How to install voice data

The following options are required to use the voice guidance function.

- EK-604/ 605 (local interface kit)


- i-Option LK-104 v3

Use USB memory to install. For the details, see the Service Manual.

4.6. How to install OCR Dictionary Data for Searchable PDF and PDF/A Font Data

Use USB memory to install. For the details, see the Service Manual.

i-Option kit is required to use these functions.

4.7. How to install Unicode Font Data and OCR Font Data

Install Font Data for USB using USB memory.

For the details, see the Service Manual.

i-Option kit is required to use these functions

4.8. How to install Loadable Driver

1. Extract the attached exe file and save "xxxxxx.tar" file to root directory of USB memory.

2. Insert the USB memory to USB port of MFP.

3. Call the Service Mode to the screen.

4. Touch [System 2] -> [Driver Install].

5. Touch [Install] -> [Loadable Driver] and [Start] to start installing the data.

6. Check that data is normally installed from the message that appears on the control panel.

7. Turn OFF/ON the main switch.

8. In the Service Mode> Billing Setting> Management Function Choice, select "Card" or "Body" in "Authentication Device2"

and press "OK" button.

9. Turn ON/OFF the main switch.

For the details, see the Service Manual.

Konica Minolta Confidential 17/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03

Konica Minolta Confidential 18/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03
5. Program that recommends applying at the same time

Please refer to the PRI for "75BW-5e/65BW-5e Mass-Production Program Function Version6 (Ver.G20-G9) (for Web Browser

(LK-101v3))" for details. (DLBT1412029EN)

6. OpenAPI supported function level

The following is OpenAPI supported function level on this firmware.

OpenAPI:

OpenAPI Function Level 4.7

Detail:
Auth 1.0/1.1/2.0/2.1/2.5/3.5/3.6/3.7/4.0/4.1/4.2/4.5/4.6/4.7

Scan to Application 2.0/2.1/2.2/3.0/3.1/3.5/3.6/3.7/4.0/4.5/4.6

PullPrint 1.0/1.1/2.0/2.1/2.5/3.5/3.6/4.0/4.5/4.6/4.7

Other A 1.0/3.5/4.0

Job Management 1.0/3.5/3.6/4.0

Setup 1.0/1.1/1.2/1.3/2.0/2.1/2.5/3.5/3.6/3.7/3.8/4.0/4.1/4.2/4.5/4.6/4.7

Link 4.5/4.6/4.7

Auth 1.0/1.1/1.5/3.5/3.6/3.7/4.0/4.1/4.2/4.5/4.7

Scan to Application 1.0/1.1/3.5/3.6/3.7/4.0/4.1/4.5/4.6/4.7

PullPrint 1.0/1.1/1.5/3.5/3.6/4.0/4.1/4.5
Web Browser
ScrSvr 1.0/3.5/4.0

Launcher 1.0/3.5/4.0

General 4.0/4.1/4.5/4.6

7. IWS function level

IWS function Level 2.0.4

* Company names and product names in this document are the registered trademarks for respective companies.

Copyright(C) 2016 KONICA MINOLTA, INC.

Konica Minolta Confidential 19/20


Program Release Information
CSES ID-No. DLBT1600291EN
Model: 75BW-5(e) Series
MFP firmware Ver. G20-K8
Subject: 75BW-5(e) Series Mass-Production Program Maintenance Release6 Function Version7 (Ver. G20-K8) (for Web
Browser (LK-101v3))
2016/02/03

Konica Minolta Confidential 20/20

You might also like