You are on page 1of 2

DRW171148AA

MULTI FUNCTION TIMER 48 15


64.5
50
(unit: mm)
Model AT8N-

AT8N SERIES Function


Control time setting range 1
0.05 sec to 100 hour
INSTRUCTION MANUAL •100-240VAC 50/60Hz, 24-240VDC universal

44.8
Power supply
•24VAC 50/60Hz, 24VDC universal • 12VDC
Allowable voltage range 90 to 110% of the rated voltage
Thank you for choosing our Autonics product. •Max. 4.3VA (100-240VAC ), Max. 2W (24-240VDC )
Power consumption
•Max. 4.5VA (24VAC ), Max. 2W (24VDC ) •Max. 1.5W (12VDC )
48.6 20 Min. 65 Return time Max. 100ms
45 5 Time operation Power ON Start
Please observe all safety considerations for safe and proper product operation to avoid hazards. Time limit DPDT (2c) or Instantaneous SPDT (1c)+Time limit SPDT (1c)
Control Contact type
Safety considerations are categorized as follows. selectable by output operation mode
45 +0.6
0 output
Contact capacity 250VAC 5A resistive load

36

16
44.9
Failure to follow these instructions may result in serious injury or death.
Failure to follow these instructions may result in personal injury or product damage. Relay Mechanical Min. 10,000,000 operations
Min. 65 life cycle Electrical
45 +0.6 Min. 100,000 operations (250VAC 5A resistive load)
The symbols used on the product and instruction manual represent the following 0

symbol represents caution due to special circumstances in which hazards may occur. Repeat error Max. ±0.2% ±10ms
55 15
Setting error Max. ±5% ±50ms
21 Voltage error Max. ±0.5%
31 Temperature error Max. ±2%
Insulation resistance 100 (at 500VDC megger)
56 Dielectric strength 2,000VAC 50/60Hz for 1 minute
Failure to follow this instruction may result in fire, personal injury, or economic loss.
Environ- Ambient temp. -10 to 55 , Storage: -25 to 65
Failure to follow this instruction may result in electric shock or fire. [t: Setting time, t>t-a, Rt: Return time, Rt1>Rt] ment Ambient humid. 35 to 85%RH, Storage: 35 to 85%RH
Failure to follow this instruction may result in electric shock or fire. Approval
t Rt1 t Rt1 t-a Accessory Bracket
Failure to follow this instruction may result in fire. A
Power 2-7 Weight 2 Approx. 134.12g (approx. 86.71g)
Failure to follow this instruction may result in electric shock or fire. Time limit contact N.C. 1-4 (8-5) 2: The weight includes packaging. The weight in parenthesis is for unit only.
Time limit contact N.O. 1-3 (8-6) Environment resistance is rated at no freezing or condensation.

Time limit output indicator


Operation/Power indicator
t Rt1 t Rt1 t-a
A1
Power 2-7 4 5 4 5
Time limit contact N.C. 8-5 CONTACT CONTACT
0.5sec 0.5sec 3 6 OUT: 3 6 OUT:
Time limit contact N.O. 8-6
250VAC 5A 250VAC 5A
Instantaneous contact N.C. 1-4 RESISTIVE RESISTIVE
2 7 2 7
Instantaneous contact N.O. 1-3 LOAD LOAD
Time limit output indicator 1 8 1 8
(
AT 8 N - Operation/Power indicator
Power supply 100-240VAC 50/60Hz, 24-240VDC
1 1
1 12VDC t Rt1 t Rt1 t-a
2 24VAC 50/60Hz, 24VDC B 1: AC/DC voltage: 100-240VAC 50/60Hz, 24-240VDC
Power 2-7 : 24VAC 50/60Hz, 24VDC
Time operation Time limit 2c or DC voltage: 12VDC
Time limit contact N.C. 8-5
N Instantaneous 1c + Time limit 1c
selectable by output operation mode Time limit contact N.O. 8-6
Number of plug pins Instantaneous contact N.C. 1-4
8 8-pin plug type 1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
Instantaneous contact N.O. 1-3 2. 12VDC, 24VDC, 24VAC power supply should be insulated and limited voltage/current or Class 2, SELV
Item
AT Analog Timer Time limit output indicator power supply device.
Sockets (PG-08, PS-08(N)) are sold separately. Operation/Power indicator 3. When supplying or turning off the power, use a switch or etc. to avoid chattering.
4. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
t t t-a Rt1 t t t
F
Power 2-7 If connect as (Figure 1), it may cause malfunction due to leakage current.
(Figure 1) (Figure 2)
Operation/Power indicator Time limit contact N.C. 1-4 (8-5)
Leakage
(Flashes for timer operation, Time limit output indicator Time limit contact N.O. 1-3 (8-6) current R
Power T Timer Power T
Turns ON for timer stop) Time limit output indicator R C
C Timer

Time range indication Output operation mode indicator Operation/Power indicator


6. Keep away from high voltage lines or power lines to prevent inductive noise.
Time range setting switch t t t-a Rt1 t t t
F1
Power 2-7 wire at input signal line.
Time unit indication Do not use near the equipment which generates strong magnetic force or high frequency noise.
Output operation mode setting switch Time limit contact N.C. 8-5
Time limit contact N.O. 8-6
Instantaneous contact N.C. 1-4
Altitude max. 2,000m
Instantaneous contact N.O. 1-3 Pollution degree 2
Time range Time unit Time setting range Time range Time unit Time setting range
Time limit output indicator Installation category II
0.5 0.05 to 0.5 sec 0.5 0.05 to 0.5 hour
Operation/Power indicator
1.0 0.1 to 1 sec 1.0 0.1 to 1 hour
sec t Rt1 t Rt1 t-a Photoelectric Sensors Temperature Controllers
5 0.5 to 5 sec 5 0.5 to 5 hour I Fiber Optic Sensors Temperature/Humidity Transducers
Power 2-7 Door Sensors SSRs/Power Controllers
10 1 to 10 sec 10 1 to 10 hour Door Side Sensors Counters
Time limit contact N.C. 8-5
0.5 0.05 to 0.5 min 0.5 0.5 to 5 hour Area Sensors Timers
Time limit contact N.O. 8-6 Proximity Sensors Panel Meters
1.0 0.1 to 1 min 1.0 1 to 10 hour Pressure Sensors Tachometers/Pulse (Rate) Meters
10h Instantaneous contact N.C. 1-4 Rotary Encoders Display Units
5 0.5 to 5 min 5 5 to 50 hour Connector/Sockets Sensor Controllers
Instantaneous contact N.O. 1-3 Switching Mode Power Supplies
10 1 to 10 min 10 10 to 100 hour 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Time limit output indicator Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables South Korea, 48002
Operation/Power indicator Stepper Motors/Drivers/Motion Controllers TEL: 82-51-519-3232
Graphic/Logic Panels sales@autonics.com
Field Network Devices
Laser Marking System (Fiber, Co , Nd: YAG) DRW171148AA
Laser Welding/Cutting System
8/9/2018 ATE-60S ( AC110/220V)" Autonic Analog Timer - ATE-60S ( AC110/220V)" Autonic Analog Timer Exporter, Importer, Manufacturer, Distributor, Supplier, Trading Company, Noida, India

+919632491583 Search Product/Service...


SHREE BRIJBEHARI
ENGINEERING PRIVATE LIMITED

Home Page Company Profile Our Products Contact Us SEND INQUIRY

Home » Products » Autonics Analog Timer » ATE-60S ( AC110/220V)" Autonic Analog Timer
OUR PRODUCTS

Autonics Temperature Controllers


ATE-60S ( AC110/220V)" Autonic Analog Timer
<<
Autonics Counters
Previous Next
Autonics Timer
>>

Autonics Analog Timer

Autonics Connectors/Cables

Delta AC Motor Drives

Delta AC Servo Motors and Drives

Delta Programmable Logic Controller

Delta Human Machine Interface

Delta Text Panel


ATE-60S ( AC110/220V)" Autonic Analog Timer

Delta Industrial Power Supply

Autonics Indicators GET A PRICE/QUOTE ASK A QUESTION SEND INQUIRY

Autonics Panel MultiMeters


Product Code : ATE - 60S

Autonics Ampere meter Series Product Description

ATE-60S ( AC110/220V)" Autonic Analog Timer


Autonics Pulse(Rate) Meters Simple functionality timer ATE Series makes cost-effective, easy and simple time setting possible. Various time ranges provide the suitable timing solution for customers’ environment.
Main Features

Autonics Graphic Touch Panels


● DIN W48×H48mm
Autonics Logic panels touch screen HMI ● Easy and simple time setting
● Cost-effective
● Easy time setting
Autonics Power controllers
● Wide range of time
● Power supply
Autonics SSR • ATE : 110/220VAC 50/60㎐
• ATE1, ATE2 : 110VAC, 220VAC 50/60Hz, 12VDC, 24VDC(option)
Autonics THYRISTOR UNIT

Autonics Recorder-Data Logger

Autonics Pressure Transmitter

Autonics Stepper Motor and Drive

Autonics Tower light

Sick Color Eye Mark Sensor

Sick Incremental Encoders

Sick Photoelectric sensors

Sick Encoders

Sick Proximity Sensors

Sick Opto-electronic protective devices

Sick Magnetic Cylinder Sensors

Sick Identification Solutions

Autonics Tacho/Speed meter Series

Autonics Sensor controller

Autonics Proximity Sensor

Sick Mounting Bracket

Sick Safety Light Curtain

Sick Connector Cable- Sensor & Encoders

Sick Capacitive proximity sensor

Sick Contrast Sensor

Sick Detection and Ranging Solutions

Autonics Converters

Delta Temperature Controlletrs

Autonics Control Switches

Sick Safety Switches

Autonics Switching Mode Power Supplies(SMPS)

SHREE BRIJBEHARI ENGINEERING PRIVATE LIMITED

Describe Your BUYING Requirement *


* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.

I am interested in your products. Please contact me back on email/phone.

+ Add Attachment

Email * Mobile No.*

Enter your email +92 Enter your Mobile

Send Inquiry

Other Products in 'Autonics Analog Timer' category

TZN4L-14C (1)'Autonics Temperature controllers ATE10S ( AC110/220)" Autonic Analog Timer ATE-30S ( AC110/220V)' Autonic Analog Timer

Send Inquiry Send Inquiry Send Inquiry

ATE1-60S Autonic Analog Timer AT11DN (24-240VAC/DC)" Autonic Analog Timer AT8PMN-2 ( 24VAC/24VDC ) Autonic Analog timer

Send Inquiry Send Inquiry Send Inquiry

View all products(26)

<< Back

Most Popular Products

Safety Encoders Cylindrical Photoelectric Sensors Small Photoelectric Sensors Analog Positioning Sensors

Contact Details Quick Links


Send Inquiry
SHREE BRIJBEHARI ENGINEERING PRIVATE LIMITED Home Page

C- 88, First Floor, Sector-65, Noida - 201307, Uttar Pradesh, India


Company Profile

http://www.autonicssensors.com/ate-60s-ac110-220v-autonic-analog-timer-3077247.html 1/2

You might also like