You are on page 1of 4

Inst Maint & Wiring_5.

qxd 20/11/2015 11:37 AM Page 6

WIRING DIAGRAMS - STANDARD MOTORS


These diagrams apply to STANDARD 3Ø WIRING DIAGRAMS 3Ø WIRING DIAGRAMS
FRAME INDUCTION MOTORS which
are used in the following products:- Diagram DD1 Diagram DD3
Pgs SINGLE SPEED MOTORS TWO-SPEED MOTORS
refer to the name plate data for correct in Dahlander connection (tapped winding)
AD/E..D/V Alpha/Beta Series D-4/6 connection High speed
Diags. DD 4, 5, 6, 7 L1 L2 L3 E
For delta ( ) wired motors Red
AD/E..S Alpha Series Supply D-13/15 L1 L2 L3 E Leads
U1 V1 W1
Diags. DD 4, 5, 6, 7 W2 U2 V2 Black
*AL.. Centrifugal fans E-10/15 U2 V2 W2
Leads
Diags. DD 1, 2, 3 U1 V1 W1
*AP/APV.. Axial Flow fans B-50/53
Diags. DD 1, 2, 3, 6, 7, 9
*APB.. Belt-driven axial fans B-50/53 Low speed
Diags. DD 1, 2, 3, 6, 7, 9 L1 L2 L3 E
For star ( ) wired motors
*APS.. Belt-driven axial fans B-50/53 L1 L2 L3 E
Diags. DD 1, 2, 3, 6, 7, 9 W2 U2 V2
Red
BFA.. Bifurcated fans B-50/53 U1 V1 W1
Leads
Diags. DD 1, 2, 3, 6, 7, 9 U1 V1 W1
Black
CGD/E.. GE Series D-58/59 Leads
U2 V2 W2
Diags. DD 1, 2, 3, 8, 9
Suggested wiring arrangement
*CHD/E.. Heritage Series D-48/49
Diags. DD 1, 2, 3, 8, 9 L1 L2 L3 N

*CHS.. Heritage Smoke-Spill D-50/51 Diagram DD2


Diags. DD 1, 2, 3
TWO-SPEED MOTORS
CPD/E.. Compact 2000 A-16/18 with 2 separate windings (dual winding)
Diags. DD 1, 4, 5, 6, 7
High speed
*FL..DD FlexLine Series E-3/6
L1 L2 L3 E
Diags. DD 1, 2, 3 Red LO SPEED STAR POINT HI SPEED
U1 V1 W1 CONTACTOR CONTACTOR CONTACTOR
Leads OVERLOAD
FP.. Compact F/Proof Series A-26/27 OVERLOAD

Diag. DD 8 Black
U2 V2 W2
Leads
*HC.. High Capacity Series D-60/62
RED
RED

RED

Diags. DD 1, 2, 3
BLACK
JV.. JetVent Axial F-4/5 M BLACK
Diags. DD 1, 2, 3 3~
Low speed BLACK

*MMD/E.. Multiflow Series B-42/46 L1 L2 L3 E


Diags. DD 1, 2, 3, 5, 6, 9
OFF
*PCD/E.. PowerLine Series B-34/36
Diags. DD 1, 2, 3, 7, 9
LO HI

Red
U1 V1 W1
*RDE.. New Generation Series D-16/19 Leads SELECTOR SWITCH

Diags. DD 1, 2, 3, 9
Black
U2 V2 W2
*RDLE.. Alpha/Beta Industrial D-7/9 Leads Diagram DD4
Diags. DD 1, 2, 3, 9
Single speed only
*RDS.. New Generation Series D-16/19 Suggested wiring arrangement
Codes: ..31. and ..35.
Diags. DD 1, 2, 3, 9 L1 L2 L3 N 9
L1 L2 L3 N E
RSS.. New Generation Series D-16/19
U1 - Red
Diags. DD 1, 2, 3, 9
*RVE.. New Generation Series D-16/19
V1 - Yellow
M
Diags. DD 1, 2, 3, 9
W1 - Blue/Black
3~
*RVLE.. Alpha/Beta Industrial D-7/9
Diags. DD 1, 2, 3, 9 Thermal
LO SPEED HI SPEED Contacts (TB)
CONTACTOR White, if fitted
SCD/E... Short Cased Series B-26/27 CONTACTOR
OVERLOAD OVERLOAD

Diags. DD 4, 5, 6, 7
*SQ.. SQ Series A-23/25
RED

RED

RED

Diags. DD 1, 2, 3, 9
N
BLACK

M
SS.. Smoke-Spill Series D-60/62 3~
BLACK

Diags. DD 1, 2, 3
BLACK

OFF

LO HI
*NOTE: Refer to the motor manufacturer’s
SELECTOR SWITCH
data on the motor for wiring diagrams on
standard frame Ex e, Ex d etc. motors.

These diagrams are current at the time of publication, check the wiring diagram supplied with the motor.

N-6 INSTALLATION, WIRING DIAGRAMS & FAN TROUBLE SHOOTING © FANTECH 2016
Inst Maint & Wiring_5.qxd 20/11/2015 11:37 AM Page 7

WIRING DIAGRAMS - STANDARD MOTORS

1Ø WIRING DIAGRAMS
3Ø WIRING DIAGRAMS (Form A) 1Ø WIRING DIAGRAMS
Diagram DD5 Diagram DD6 Diagram DD8
Airflow *
TWO-SPEED MOTORS L N E
High speed delta ( ) connection
Anti-Clockwise
Codes: ..40. to 63. M
L1 L2 L3 E W2 or White
Airflow
1~
Thermal
U1 or Red L N E
M
contacts (TB)
M
U2 or Black
white
V1 or Yellow
V2 or Orange
3~ Z1
Cap. 1~
W1 or Blue
L1
Thermal
Contacts (TB) U2
S/C L2
White Z2
N U1 Diagram DD9
Low speed star ( ) connection
L N E
Codes: ..40. and upwards
White
L1 L2 L3 E
W2 or White
Z1 - Blue (AUX)
U2 - Black (MAIN)
Z2 - Yellow
U1 - Red }(COM) L1
Brown M
S/C L2
1~
U2 or Black
V2 or Orange
M Bridge L1 and L2 if speed
controller (S/C) is not required
N
Blue
U1 or Red
V1 or Yellow
3~
W1 or Blue Note:
This diagram suits speed controllers, VA2.0
Thermal Bridge L1 and L2 if speed
Contacts (TB) and VA2.8 only. When using the AVA5.0,
White VA5.0 and VA8.0 speed controllers, controller (S/C) is not required
use the AUX, MAIN and COM connections.

* Airflow direction base on left-hand blade installation.

For all other SINGLE-PHASE wiring


(Form B) diagrams refer to the manufacturers
data on the motor.
Diagram DD7
Airflow
*
Clockwise

Airflow

Thermal
L N E contacts (TB)
white
Z2 M
Cap. 1~
L1
U2
S/C L2
Z1
N U1

Z2 - Yellow (AUX)
U2 - Black (MAIN) }
Z1 - Blue (COM)
U1 - Red

Bridge L1 and L2 if speed


controller (S/C) is not required

Note:
This diagram suits speed controllers, VA2.0
and VA2.8 only. When using the AVA5.0,
VA5.0 and VA8.0 speed controllers,
use the AUX, MAIN and COM connections.
N
* Airflow direction base on left-hand blade installation.

These diagrams are current at the time of publication, check the wiring diagram supplied with the motor.

© FANTECH 2016 INSTALLATION, WIRING DIAGRAMS & FAN TROUBLE SHOOTING N-7
Inst Maint & Wiring_5.qxd 20/11/2015 11:37 AM Page 8

WIRING DIAGRAMS - EXTERNAL ROTOR MOTORS


These diagrams mainly apply to 3Ø WIRING DIAGRAMS 1Ø WIRING DIAGRAMS
EXTERNAL ROTOR MOTORS but Diagram ER1 Diagram ER4
some standard frame induction motor 3 active wires plus Single phase
diagrams have been included for ease TWO-SPEED MOTORS
auto-reset AC motor
of presentation. Pgs High speed Orange Red Grey
thermal contacts with capacitor
L1 L2 L3 E
CD/E..D/V Gamma Series D-22/25 W2 U2 V2
L N E A N
Diags. ER 1, 2, 4, 5 Brown Blue Black
Brown
M

Green/Yellow

Blue or Grey
Cap
CD/E..VGL GL Gamma Series D-38/40 U1 V1 W1 Black
Diags. ER 1, 2, 4, 5 1~

Brown
Blue

CD/E..S Gamma Supply Series D-32/33


Diags. ER 1, 2, 4, 5 M Black

CF.. Compact axial fans B-3 1~


Low speed Orange Red Grey
Single-phase motors L1 L2 L3 E Codes: CE19.. to CE28..
Diag. ER 6 W2 U2 V2 + other fans as shown CE31 only
EDM.. EDM Series A-4/5 Brown Blue Black

Diags. ER 6, 7 U1 V1 W1 Diagram ER5


FSU146 Diag. ER 11 A-32 4 active wires plus manual-reset
thermal contacts
GRE.. Sigma Series E-2 L N E
Diag. ER 4 Orange
L1
HB.. Header Box A-33
Diag. ER 4
Diagram ER2 S/C L2
Blue
Black
M
TWO-SPEED MOTORS Brown 1~
HCM... HCM Series A-10/11 N

Diag. ER 4 High speed Yellow Green White

L1 L2 L3 E Thermal
HV.. Stylvent Series A-12/13 W2 U2 V2 Contacts (TB)
White
Diags. ER 6, 8 Black Blue Brown Bridge L1 and L2 if speed
HXM.. HXM Series A-15 U1 V1 W1 controller (S/C) is not required
Diag. ER 6 Codes: CE35.. and over + other fans as shown
MT.. Minitube Series B-24/25
Diags. ER 4, 6 Diagram ER6
MV..E Minivent Exhaust Series D-2/3 Codes: EDM..S & ..C; HV-150AE;
Low speed Yellow Green White
Diags. ER 4, 6 L1 L2 L3 E MT132; MV112 & MV132
MV..S Minivent Supply Series D-13/15 W2 U2 V2 SILDES
Diags. ER 4, 6 Black Blue Brown L N E

PC..ER PowerLine Series B-34/36 U1 V1 W1


Diags. ER 1, 2, 3, 4, 5 M
RP.. Ring Plate Series A-8/9 1~
Diag. ER 4
VM.. VentMajor Series B-4/5
Diag. ER 6
SILDES Silent Design Series A-2/3 Diagram ER7
Diag. ER 6
1Ø WIRING DIAGRAM Codes: EDM..CT & ..CR
EWE Ezifit Thru Wall A-30/31
Diag. ER 4
Diagram ER3 L N E

L N E 9
White
M
L1
1~
S/C L2
Brown M
N
Blue 1~

Bridge L1 and L2 if speed


Diagram ER8
controller (S/C) is not required Codes: HV-230AE & HV-300AE
Exhaust air mode. For supply air mode
bridge LA & LC do not bridge LA & LB.
L N E

N
LC
LB
LA
N

These diagrams are current at the time of publication, check the wiring diagram supplied with the motor.

N-8 INSTALLATION, WIRING DIAGRAMS & FAN TROUBLE SHOOTING © FANTECH 2016
Inst Maint & Wiring_5.qxd 20/11/2015 11:37 AM Page 9

WIRING DIAGRAMS - EXTERNAL ROTOR MOTORS


These diagrams apply to EXTERNAL
ROTOR MOTORS that are fitted to the
following products:-
Pgs
EIE.. Ezifit In-Wall A-28/29
Diag. ER 10
JISU.. JetVent Centrifugal F-8/9
Diag. ER 9
JIU.. JetVent Multiflow F-6/7
Diag. ER 9
JVW.. JetVent Warehouse G-4
Diag. ER 9

These diagrams are current at the time of publication, check the wiring diagram supplied with the motor.

© FANTECH 2016 INSTALLATION, WIRING DIAGRAMS & FAN TROUBLE SHOOTING N-9

You might also like