Memorandum and draft of proposed revisions to Ch. 301 ("Zoning") of the Riverhead Town Code DC-1 ("Main Street") zoning use district discussed by the town board at its work session of Nov. 1, 2018.
Original Title
Draft of Proposed Revisions to Riverhead Town Code Ch. 301 (DC-1/Main Street)
Memorandum and draft of proposed revisions to Ch. 301 ("Zoning") of the Riverhead Town Code DC-1 ("Main Street") zoning use district discussed by the town board at its work session of Nov. 1, 2018.
Memorandum and draft of proposed revisions to Ch. 301 ("Zoning") of the Riverhead Town Code DC-1 ("Main Street") zoning use district discussed by the town board at its work session of Nov. 1, 2018.
TOWN OF RIVERHEAD
) Planning Department -
201 Howell Avenue, Riverhead, New York 11901-2596
(631) 727-3200, Fax (631) 727-9101
‘won ownoftiverheady gov
Jefferson ¥ Murphree, AICP Karin Gluth vacant Greg Bergman Carissa Collins
Building & Planning Planner Exvtronmenal Planner Planing Aide Planning Board Secretary
Administrator Ext 206 Ext 264 Zoning Board Secretary
Ext. 239 Ext. 240
Intra-Agency Memorandum
TO: Laura Jens-Smith, Supervisor
‘Town Board Dimon
Robert Kozakiewicz, Town Attorney [Ss 9P
wu WY
FROM: —_ Jefferson V. Murphree, AICP Building and Planning Administrator
SUBJECT: Proposed Code Amendments to the Downtown (DC-1) Main Street Zoning Use District
DATE: Cctober 31, 2018
Please find a copy attached of draft code amendments to Chapter 301 to change the dimensional
requirements in the downtown (DC-1) zoning district. These proposed changes are only preliminary
suggestions and were prepared to fully evaluate potential code amendments. These amendments would
apply to ll properties currently zoned DC-1 on SR 25 (Main Street).
The following code amendments are proposed (Pages 1-6 and the Schedule of dimensional Regulations):
1. Themaximum building height would be 24 feet (2 stories) with commercial uses required on the first
floor.
The maximum building height could be increased to 36 feet (3 stories) with the transfer of
development rights (TDR). One TDR would equal 3,000 square feet of gross floor arca (proposed).
The Transfer of Development Rights (TDR) code would need to be amended to include the DC-1
zoning district as a receiving area.
There would be a requirement for any 3* floor development to be setback 15 feet from any front yard.
The maximum building height could be increased to 48 feet (4 stories) with the transfer of
development rights (TDR). One TDR would equal 3,000 square feet of gross floor area (proposed 34
and 4* floor combined). The Transfer of Development Rights (TDR) code would need to be amended
to include the DC-1 zoning district as a receiving area.
25. There would be a requirement for any 4th floor development to be setback 30 feet from the front and
rear yard
6, The maximum impervious surface would be reduced from 100% down to 80% to allow for public
space. The Floor Area Ratio (FAR) would be reduced proportionately.
7, Design Standards would be more specific, ie. no stucco would be allowed as a primary building
material.
Finally, Section 301-246 Supplementary Area Regulations (see Page 8) currently allows the Town Board
to approve development in the DC-1 zoning use district to have a zero (0) foot front yard depth and 100%
building area. It is recommended this section of the Code’be deleted because it inconsistent with the
intent and purpose of the proposed legislation,
Please contact me if you have any questions.
Wik e |
ce: Anne Marie Prudenti, Deputy Town Attorney
Dawn Thomas, Community Development Director
Brad Hammond, Chief Building InspectorFigure One
Proposed DC-1 Dimensional Amendments
‘a floor
48 ft asst asf
setback setback
3" floor i ase
aor sath aan
2" floor 7
2aft Pou
1" floor 12 ft
th | th tht
Frontyad Rear yard
Note: Motto scale. For itustration purposes only