Oily Water Drain Arrangement

Contents: Page

1. Introduction 1

2. Execution 1

3. Related Service Bulletins 4

Wärtsilä Switzerland Ltd PO Box 414 Tel. +41 52 262 23 30


Wärtsilä Schweiz AG CH-8401 Winterthur Fax +41 52 212 07 31
Wärtsilä Suisse SA Switzerland E-mail: techservice.ch@wartsila.com
1 INTRODUCTION
The scavenge air receiver compartments are provided with drains to remove oily water. In
some cases the drain pipes of the receiver compartments before and after the Flap-valves or
Reed-valves are connected to a common drain line.
During auxiliary blower operation the pressure difference between the compartments before
and after the flaps may cause back-flow of oily water to the compartment before the flaps,
contaminating both the receiver space and the water separator.
For those engines that have a direct connection between these compartments via a common
drain line (as described above), an orifice plate fitted in the drain pipe of the space after the
water separator will prevent this contamination.

2 EXECUTION
The recommended diameter of the orifice is 8 mm.
The orifice plate should be made of stainless steel or brass to prevent rusting, with a thickness
of 3 to 4 mm.
The orifice plate should be fitted in a vertical part of the drain pipe close to the common drain
line.
If the drain of the compartment after the water separator is fitted with a butterfly valve close
to the common drain line, the orifice may be drilled in the valve.
Couplings, flanges and valves that are fitted with an orifice should be clearly marked
indicating the orifice location and size. An example is shown on page 3 for an orifice plate
fitted in a flange coupling.
The orifice plates should be periodically checked for obstruction and erosion e.g. every six
months.

1/4 Service Bulletin RTA-75 / RT-flex-04


2.1 Examples of various executions

RTA48T-B

Receiver space after flaps Receiver space before flaps

Oily water back-flow


during auxiliary
blower operation

Common drain line

8 mm orifice plate to be fitted in the Straub coupling

2/4 Service Bulletin RTA-75 / RT-flex-04


RT-flex96C-B

Oily water back-flow


8 mm orifice plate to be fitted
in flange coupling

Common drain line

Tab indicating orifice location and size

3/4 Service Bulletin RTA-75 / RT-flex-04


RT-flex84T-D

Oily water backflow

8 mm orifice to be
drilled in butterfly
valve
Common drain line

3 RELATED SERVICE BULLETINS

RTA-62 Prevention of Water Carry-Over and Liner Polishing


RTA-74 Condensate Drain Arrangement of the Scavenge Air Cooler