You are on page 1of 22

DIGITAL MULTIFUNCTION METER

Picture FuncƟon DescripƟon Type Size Price (Rp)


• 3Ɍ ( True rms ) Voltage 3Phase LCD MulƟfuncƟon Meter
• 3Ɍ ( True rms ) Current > With bargraph of Current MFM384-C 96 X96 2,750,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh > With CommunicaƟon (RS485)
• 3Ɍ Power Factor > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Frequency
• Total Harmonic DistorƟon 3Phase LCD MulƟfuncƟon Meter
• Demand (Min/Max AcƟve Power, Min/Max > With bargraph of Current MFM384 96 X96 2,000,000
ReacƟve Power, Max Apparent Power ) > Without CommunicaƟon (RS485)
• Programmable CT/PT Pramary / Secondary > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Modbus RTU communicaƟon (RS485)
• Pluse Output

• 3Ɍ ( True rms ) Voltage 3Phase LCD MulƟfuncƟon Meter


• 3Ɍ ( True rms ) Current > With CommunicaƟon (RS485) MFM383A-C 96 X96 1,520,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• 3Ɍ Power Factor
• Frequency
• Programmable CT/PT Pramary / Secondary 3Phase LCD MulƟfuncƟon Meter MFM383A 96 X96 1,265,000
• Modbus RTU communicaƟon (RS485) > Without CommunicaƟon (RS485)
• Pluse Output > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W

• 3Ɍ ( True rms ) Voltage 3Phase LED MulƟfuncƟon Meter


• 3Ɍ ( True rms ) Current > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W MFM376 96 X96 1,050,000
• kW, kVA, kVAr, KWh, kWAh, kWArh
• 3Ɍ Power Factor
• Frequency
• Demand (Min/Max AcƟve Power, Min/Max
ReacƟve Power, Max Apparent Power )
• CT Polarity Error
• Single Pluse Output

1
DIGITAL VAF & ENERGY METER (KWh)

Picture FuncƟon DescripƟon Type Size Price (Rp)


• 3Ɍ ( True rms ) Voltage 3Phase LCD (V, A, Hz) Meter
• 3Ɍ ( True rms ) Current > With bargraph of Current VAF36A 96 X 96 930,000
• Frequency (HZ) > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Run Hour ( hour meter )
• RPM
• Programmable CT Primary
• Programmable PT Primary & PT Secondary

• 3Ɍ ( True rms ) Voltage 3Phase LED (V, A, Hz) Meter


• 3Ɍ ( True rms ) Current > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W VAF39A-1 96 X 96 600,000
• Frequency (HZ)
• Run Hour ( hour meter )
• RPM
• Programmable CT Primary
• Programmable PT Primary & PT Secondary

• 3Ɍ Power ( AcƟve, ReacƟve ) 3Phase LCD Energy Meter


• 3Ɍ Power Factor > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W EM368-C-CU 96 X 96 2,000,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh
• Programmable CT/PT Pramary / Secondary
• Modbus RTU communicaƟon (RS485)
• Pluse Output

• Energi AcƟve (KWh) 1Phase/3Phase LED KWh Meter


• Pluse Output > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W EM306-A 96 X 96 850,000
• Programmable CT Primery / Secondary

2
DIGITAL AMPERE METER
AC METER

Picture DescripƟon Type Size Price (Rp)


LCD Ampere Meter, 1Phase 2 Wire
> With analog style bargraph IndicaƟon MA201 72 X 72 410,000
> For 1 phase 2 wire connecƟon
> For 3 phase with selector swicth connecƟon MA301 96 X 96 410,000
> Input : 1Ɍ - 2wire ( with adapter Plate)

LCD Ampere Meter, 3Phase 4 wire


> With analog style bargraph IndicaƟon MA2301 72 X 72 500,000
> For 3 phase 4wire connecƟon
> Input : 3Ɍ - 4 wire / 3Ɍ - 3 wire MA3301 96 X 96 500,000
> Inbuilt keypad for selecƟon switch ( with adapter Plate)

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA302 96 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA202 72 X 72 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA12 48 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 3Phase 4 wire


> Input : 3Ɍ-3W/4W or 1Ɍ-2W MA335 96 X 96 400,000
> Inbuilt keypad for selecƟon switch

3
DIGITAL VOLT METER
AC METER

Picture DescripƟon Type Size Price (Rp)


LCD Volt Meter, 1Phase 2 Wire
> With analog style bargraph IndicaƟon MV207 72 X 72 410,000
> For 1 phase 2 wire connecƟon
> For 3 phase with selector swicth connecƟon MV307 96 X 96 410,000
> Input : 1Ɍ - 2wire ( with adapter Plate)

LCD Volt Meter, 3Phase 4 wire


> With analog style bargraph IndicaƟon MV2307 72 X 72 500,000
> For 3 phase 4wire connecƟon
> Input : 3Ɍ - 4 wire / 3Ɍ - 3 wire MV3307 96 X 96 500,000
> Inbuilt keypad for selecƟon switch ( with adapter Plate)

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV305 96 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV205 72 X 72 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV15 48 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 3Phase 4 wire


> Input : 3Ɍ-3W/4W or 1Ɍ-2W MV334 96 X 96 400,000
> Inbuilt keypad for selecƟon switch

4
DIGITAL VOLT & AMPERE
DC METER

Picture DescripƟon Type Size Price (Rp)


LED Volt Meter, 1Phase 2 Wire
> For 1 phase 2 wire connecƟon MV305-VDC 96 X 96 475,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> Range maximum 200VDC

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV15-VDC 48 X 96 475,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> Range maximum 200VDC

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA302-VDC 96 X 96 400,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> By Shunt Seƫng ( 5 - 4000A ), 75mV

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA12-VDC 48 X 96 400,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> By Shunt Seƫng ( 5 - 4000A ), 75mV

5
DIGITAL FREQUENCY & POWER FACTOR METER

Picture DescripƟon Type Size Price (Rp)

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF316 96 X 96 400,000
> Input : 1Ɍ - 2wire

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF216 72 X 72 400,000
> Input : 1Ɍ - 2wire

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF16 48 X 96 400,000
> Input : 1Ɍ - 2wire

LED Power factor Meter / COS Ɍ


> For 1 phase 2 wire connecƟon MP314 96 X 96 500,000
> Input : 1Ɍ - 2wire

6
POWER FACTOR CONTROLLER

Picture DescripƟon Steps Type Size Price (Rp)


Power Factor Controller
> LED display, 4 digits 8 APFC147-108 144 X 144 2,200,000
> Single CT sensing
> Dual password protecƟon
> ConĮgurable alarm seƫng
> LED indicaƟon for alarm
> Input : L-N / L-L
> CT primary 1A / 5A up to 9999A 12 APFC147-112 144 X 144 2,600,000
> CT secondary 1 or 5A
> OperaƟng limit of Voltage Input :
40-300V (L-N), 50-500V (L-L)
> Alarm seƫng :
• Over voltage, under voltage, under compensaƟon,
• Over compensaƟon, CT polarity : ON/OFF
• Current absent indicaƟon : Crr
> Switching program : AutomaƟc / Linear / RotaƟonal
> Control mode : AutomaƟc / Manual
> Step Ɵme : 5 to 240 sec

Power Factor Controller


> LCD display with dual color backlight 8 APFC148-308 144 X 144 4,500,000
> 3 CT sensing
> Alarm linked signal contact
> Programmable Fan control
> MODBUS RTU CommunicaƟon
> Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
> CT primary 1A / 5A up to 9999A 12 APFC148-312 144 X 144 5,500,000
> CT secondary 1 or 5A
> OperaƟng limit of Voltage Input :
11-300V (L-N), 50-520V (L-L)
> Alarm seƫng :
• THDI
• Over voltage, under voltage, under compensaƟon,
• Over compensaƟon, CT polarity Error ON/OFF,
• Step Error 20-80% or oī, temperature 0-100϶C or ON or OFF
• Fan seƫng ON/OFF, %THDI 20-100% or OFF
> Switching program : AutomaƟc / Linear / RotaƟonal
> Control mode : AutomaƟc / Manual
> Step Ɵme : 5 to 240 sec

7
PROTECTION RELAYS
DIN RAIL MOUNTING

> Analog ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)

Analog Phase Sequence Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure 800PSR 195,000
154 to 500VAC (L - L) , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto
raƟng : NO/5A, NC/3A, 250VAC
> Power On Delay : 200 msec
> Trip Ɵme delay : 200 msec max.
> Accuracy : Trip ±10V
> Size : 22.5 X 76.85mm
Analog Phase Sequence Relay • ProtecƟon :
> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
154 to 500VAC (L - L) , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto 600PSR 460,000
raƟng : NO/5A, NC/3A, 250VAC
> Power On Delay : 200 msec
> Trip Ɵme delay : 0.2 to 10sec
> Accuracy : Trip ±10V
> Size : 17.5 X 90mm
Analog Phase Sequence Relay • ProtecƟon :
> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
230VAC ±20% , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto PSR1 400,000
raƟng : NO/5A, 250VAC
> Power On Delay : < 500 msec
> Trip Ɵme delay : 3.5sec
> Recovery Ɵme delay :
• phase failure & asymmetry : < 120ms
• phase sequence : < 250ms
> Accuracy : Trip seƫng ±1% of F.S
Time seƫng ±5%of F.S
> Size : 35 X 90mm

Analog Phase Sequence Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
230VAC ±20% , 50/60Hz > Phase asymmetry : 30 - 70V
415VAC ±20% , 50/60Hz > VA raƟng : 4VA max
> Output contact : 2 C/O (DPDT) > Reset : auto / manual / remote PSR2 550,000
raƟng : NO/5A, NC/3A, 250VAC > Reset gap : 10V(for manual/reset)
> Power On Delay : < 500 msec
> Trip Ɵme delay : 3.5sec
> Recovery Ɵme delay :
• phase failure & asymmetry : < 120ms
• phase sequence : < 250ms
> Accuracy : Trip seƫng ±1% of F.S
Time seƫng ±5%of F.S
> Size : 52.5 X 90mm
8
PROTECTION RELAYS
DIN RAIL MOUNTING

> Voltage ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)

Analog Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Under voltage
> OperaƟng Voltage : > Over voltage trip 600VPR 500,000
310 to 520VAC (L - L) , 50/60Hz > Phase sequence / reverse
> Output contact : 1 C/O (SPDT) > Phase failure
raƟng : NO/5A, NC/3A, 250VAC > Phase asymmetry / Imbalance
> Trip seƫng : > Reset : Auto
• Under voltage trip : -2.5% to -25% of 415VAC
• Over voltage trip : -2.5% to -25% of 415VAC
> Trip Ɵme seƫng :
• Power On Delay : 400 msec
• Trip Ɵme delay : 0.2 to 10sec
> Accuracy : Trip seƫng ±5% of F.S
Time seƫng ±5%of F.S
> Size : 17.5 X 90mm

Analog Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 1Ɍ/2wire > Under voltage
> OperaƟng Voltage : > Over voltage
127 to 288VAC (L-N) , 50/60Hz > Phase sequence / reverse
> Output contact : 2 C/O (DPDT) > Phase failure
raƟng : 5A, 250VAC / 28VDC > Phase asymmetry VPRA2M 450,000
> Trip seƫng :
• Under voltage: 55-95% of Un 127 to 219VAC (L-N)
• Over voltage: 105-125% of Un 242 to 288VAC (L-N)
• Phase asymmetery : >10%
> Trip Ɵme seƫng :
• Power On Delay : 0-15sec
• Trip Ɵme delay : 0-15sec
• Recovery Ɵme delay :5s ± 200ms
• L1/neutral loss trip delay : <250ms
• phase sequence trip delay : < 250ms
> Accuracy : Trip seƫng ±5% of F.S
Time seƫng ±5%of F.S
> Size : 35 X 90mm

Digital Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3wire > Under voltage
> OperaƟng Voltage : > Over voltage
160 to 300VAC (L-N), 280 to 520 (L-L), 50/60Hz > Under frequency
> Output contact : 2 x 1 C/O (SPDT) > Over frequency 900VPR-2 650,000
raƟng : NO/5A, NC/3A, 250VAC > Phase sequence / reverse
> Trip seƫng : > Phase failure
• Under / Over voltage : > Phase asymmetry
280 to 520VAC L-L ( for 3Ɍ/3wire system) • Monitoring in 3Ɍ system
160 to 300VAC L-N ( for 3Ɍ/4wire system) • True RMS meansurement
• Under / Over Frequency : 45 - 65Hz • Power ON delay
• Phase asymmetery : 5 - 99.9% • Trip Ɵme delay
> Trip Ɵme seƫng : • Recovery Ɵme delay
• Power On Delay : 2 - 99.9sec • Adjustable switching hysteresis
• Trip Ɵme delay : 0 - 99.9sec • Two separate alarm relays
• Recovery Ɵme delay : 0 - 99.9sec
• Response Ɵme : < 200ms
> Accuracy : Voltage : ±1% of set value.
Frequency : ±0.3Hz
> Accuracy Ɵme (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng ±200ms
> Size : 35 X 90mm
9
PROTECTION RELAYS
DIN RAIL MOUNTING

> Current ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Digital Current ProtecƟon Relay • ProtecƟon :
> Input connecƟon :1Ɍ/2wire, with CT > Under current
> OperaƟng Voltage : 230VAC > Over current
> Output contact : 1 x 1 C/O (SPDT) • Monitoring in 1Ɍ system
raƟng : NO/5A, NC/3A, 250VAC • True RMS meansurement
> Trip seƫng : • Power ON delay 900CPR-1 720,000
• Under current : 0 - 999A • Trip Ɵme delay
• Over current : 0.5 - 1.19kA • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0 - 99.9s • One alarm relays with NC/NC
• Trip Ɵme delay : 0 - 99.9s
• Recovery Ɵme delay :0 - 99.9s
• Response Ɵme : < 200ms
> Accuracy :
• Current : ±1% of seƫng 2 digits
• Time (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng 2 digits
> Size : 35 X 90mm

Digital Current ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire, with CT > Under current
> OperaƟng Voltage : 230VAC / 110VAC > Over current
> Output contact : 1 x 1 C/O (SPDT) > Asymmetry current for 3Ɍ 900CPR-3 850,000
raƟng : NO/5A, NC/3A, 250VAC • Monitoring in 1Ɍ and 3Ɍ system
> Trip seƫng : • True RMS meansurement
• Under current : 0 - 999A • Power ON delay
• Over current : 0.5 - 1.19kA • Trip Ɵme delay
• Current asymmetry : 5 - 99.9% • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0 - 99.9s • One alarm relays with NC/NC
• Trip Ɵme delay : 0 - 99.9s
• Recovery Ɵme delay :0 - 99.9s
• Response Ɵme : < 200ms
> Accuracy :
• Current : ±1% of seƫng 2 digits
• Time (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng 2 digits
> Size : 35 X 90mm

10
PROTECTION RELAYS
DIN RAIL MOUNTING

> Earth Leakage ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Analog Earth Leakage Relay • ProtecƟon earth leakage current
> Input connecƟon : 3Ɍ/4Wire & 1Ɍ/2wire • Leakage current monitoring in
> OperaƟng Voltage : 230VAC, 50/60Hz 1Ɍ and 3Ɍ system
> SensiƟvity (ѐI) & Time Delay (ѐt) adjustable • CBCT open circuit indicaƟon
> Trip seƫng : • Test and reset funcƟon ELRA2M2 750,000
• Leakage current : 30mA - 30A
> Size : 35 X 90mm

Digital Earth Leakage Relay • ProtecƟon earth leakage current


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Leakage current monitoring in
> OperaƟng Voltage : 230VAC / 110VAC 1Ɍ and 3Ɍ system
> Output contact : 2 x 1 C/O (SPDT) • True RMS meansurement 900ERL-2 1,100,000
raƟng : NO/5A, NC/3A, 250VAC • CBCT connecƟon monitoring
> Trip seƫng : • Power ON delay
• Leakage current : 10mA - 30A • Trip Ɵme delay
• Pre alarm : 50 - 100% of leakage current seƫng • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0.5 - 99.9s • Test and reset via front / remote
• Trip Ɵme delay : 0 - 99.9s • Two separate alarm relays with NC/NC
• Recovery Ɵme delay : 0 - 99.9s
• Response Ɵme : < 30ms (if trip current ш 5 x set value)
< 50ms (if trip current ш 1 x set value)
> Accuracy :
• Current : ±5% of seƫng 2 digits
• Time delays : ±5% of seƫng ±100ms
> Size : 35 X 90mm

Analog Earth Leakage Relay • ProtecƟon earth leakage current


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Monitors true RMS earth fault current
> OperaƟng Voltage : 230VAC, 50/60Hz • Inbuilt CBCT ELCTR35 call
> Trip seƫng : • Test and reset funcƟon
• Leakage current : 75% of 30mA or 300mA
> Size : 74 X 105mm

> Zero CT For Earth Leakage Relay (CBCT)


Size
Picture Type CT RATIO Price (Rp)
(Inner diameter)

1200:1 430,000
35mm CBCT-35
1000:1 235,000

1200:1 490,000
70mm CBCT-70
1000:1 340,000

1200:1 840,000
120mm CBCT-120
1000:1 880,000

11
PROTECTION RELAYS
DIN RAIL MOUNTING

> Earth Fault ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Digital Earth Fault Relay • ProtecƟon earth fault current
> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Earth fault current monitoring in
> OperaƟng Voltage : 85 - 270VAC/DC, 50/60Hz 1Ɍ and 3Ɍ system 900ERF-2 1,100,000
> Trip seƫng : • RMS value measurements (AC)
• Alarm relays with NO and NC
• Up to 80% of MCCB frame raƟng
operaƟon selectable
> Size : 35 X 90mm

> Motor ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Motor ProtecƟon Relay • Single phase
> Input connecƟon : 3Ɍ / 3Wire • Phase unbalance
> OperaƟng Voltage : 230VAC, 50/60Hz • Phase sequence MPR-3M-2-230V call
> Trip Ɵme seƫng : • Under current trip
• Single phase : 5 sec • Over current trip
• Phase unbalance : 5 sec
• Phase sequence u : 5 sec
• Over load trip as per graph 1
• Under load trip : 5 sec
> Size : 52.5 X 90mm

> Water Level Controller


Picture DescripƟon FuncƟon Type Price (Rp)
Water Level Control • Used for drain and Įll cotrol
> OperaƟng Voltage : 85 - 270VAC, 50/60Hz
> Output contact : 1 C/O (SPDT) WLCA2M2 545,000
> Size : 35 X 90mm

> Weekly Timers


Picture DescripƟon Type Price (Rp)
Weekly Ɵmer
> OperaƟng Voltage : 220VAC, 50/60Hz
> Output contact : 1 C/O (SPDT) TS2M1-1 540,000
> Contact RaƟng : 16A / 250VAC
> 50 ON - OFF Step per day
> Size : 35 X 90mm

12
TIMERS
DIN RAIL MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• 13 FuncƟon, 10 Ɵme range
• Modes : A, B, C, Ci, D, E, F, H, I, J, K, Ai, Bi
• Time range : 0.1-1s, 0.3-3s, 1-10s, 3-30s,
0.1-1m, 0.3-3m, 1-10m, 3-30m, 0.1-1hr, 0.3-3hr 600XU 450,000
• Output contact : 1 C/O (SPDT)
raƟng : NO/5A, NC/3A, 250VAC
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 17.5 X 90 X 60mm

• Single FuncƟon, 10 Ɵme range


• Modes : On Delay
• Time range : 0.1-1s, 0.3-3s, 1-10s, 3-30s,
0.1-1m, 0.3-3m, 1-10m, 3-30m, 0.1-1hr, 0.3-3hr
• Output contact : 1 C/O (SPDT) 600ST 347,000
raƟng : NO/5A, NC/3A, 250VAC
• Input voltage : 240VAC, 50/60Hz
• Size : 17.5 X 90 X 60mm

• 2 FuncƟon, 12 Ɵme range, Universal voltage


• Modes : On Delay / Interval
• Time range : 1 / 3 / 10 / 30 sec / min / hr
• Output contact : 2 C/O (DPDT) 800XU 450,000
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• 2 FuncƟon, 8 Ɵme range, Universal voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 2 C/O (DPDT) 800XA 350,000
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• 2 FuncƟon, 8 Ɵme range, dual voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 1 C/O (SPDT) 800SQ-A 260,000
• Input voltage : 230-230VAC & 24VAC/DC, 50/60Hz
• Size : 22.5 X 75 X 101mm

Modes : A (On delay), B (Interval), C (Repeat Cycle Equal OFF Įrst), Ci (Repeat Cycle Equal ON Įrst),
D (Pulse Output 500ms Įxed), E (Delay on break), F (Delay on make/Delay on break),
H (Interval aŌer break), I (Single short), J (Retriggerable single short), K (Latching relay),
Ai (Delay on make with totalise), Bi (Interval with totalise).
13
TIMERS
DIN RAIL MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• Single FuncƟon, Single Ɵme range
• Modes : On delay
• Time range : 30sec and 60sec 800S - 30S 245,000
• Output contact : 1 C/O (SPDT)
• Input voltage : 230VAC/50Hz 800S - 60S 245,000
• Size : 22.5 X 75 X 101mm

• Single FuncƟon, Single Ɵme range


• Modes : True power OFF delay 800POD - 60S 865,000
• Time range : 60sec and 180sec
• Output contact : 2 C/O (DPDT) 800POD - 180S 865,000
• Input voltage : 110 - 240VAC/DC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• Cyclic with unequal ON & OFF Ɵme


• Modes : Asymmetrical cyclic ON Įrst or OFF Įrst
• Time range : 1 / 10 /sec/min/hr for both ON & OFF Ɵme
• Output contact : 2 C/O (DPDT)
• Input voltage : 20-240VAC / 12-240VDC, 50Hz 800XC 500,000
• Size : 22.5 X 75 X 101mm

• FuncƟon for Forward - Pause - Reverse


• Modes : Forward - Pause - Reverse
• Time range : ON Ɵme : 1/2/4/8 min
Pause Ɵme : 10/20/40/80 Sec 800XMR 600,000
• Output contact : 1 C/O each for forward & Reverse
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• FuncƟon for Star - Delta Ɵmer


• Modes : Star - Delta
• Time range : Run up Ɵme range : 30/60 sec
Change over Ɵme : 50/100 sec 800SD-2 330,000
• Output contact : 1 C/O relay each for star - delta
• Input voltage : 230VAC, 50HZ
• Size : 22.5 X 75 X 101mm

14
TIMERS
PIN PLUG MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• 2 FuncƟon, 12 Ɵme range, Universal voltage
• Modes : On delay / Interval
• Time range : 1 / 3 / 10 / 30 sec / min / hr 55XU-P8 460,000
• Output contact : 2 C/O (DPDT)
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 48 X 48mm

• 2 FuncƟon, 8 Ɵme range, dual voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min 55ES-P8 280,000
• Output contact : 1 C/O (SPDT)
• Input voltage : 230-230VAC & 24VAC/DC, 50/60Hz
• Size : 48 X 48mm

• 2 FuncƟon, 8 Ɵme range


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 2 C/O (DPDT) 55Q-P8 350,000
• Input voltage : 230VAC/ 50Hz
• Size : 48 X 48mm

> Digital Timers ( Panel MounƟng )


Picture DescripƟon Type Price (Rp)
• 2 FuncƟon, 3 digits LED
• Modes : On delay / Interval
• Time range : 9.99/99.9/999sec, 99.9/999min, 99,9hr XT56N 900,000
• Output contact : 2 C/O (DPDT)
• Input voltage : 97 - 270V AC/DC, 50/60Hz
• Size : 48 X 48mm

• 4 FuncƟon, 3 digits LED


• Modes : On delay / Interval / Cyclic ON or OFF Įrst
• Time range : 9.99/99.9/999sec, 9.59min : sec, XT546 750,000
99.9/999min, 9.59hr : min, 99.9/999hr
• Output contact : 2 C/O (DPDT)
• Input voltage : 85 - 270V AC/DC, 50/60Hz
• Size : 48 X 48mm

15
RATE INDICATORS
PANEL MOUNTING

Picture DescripƟon Size Type Price (Rp)


• Time Totaliser
• LCD display , 8 digits LT945V 315,000
• Time range : 999999.99 hr 48 X 48
• Input Type : a) 24 - 260 VAC LT945C 315,000
b) Contact
• Input voltage : baƩery powered

• RPM Meters 48 X 48 RC5100 775,000


• LED display , 4 digits (sensor PNP)
• Range : 4.00 to 9999 RPM
• Input Speed : 4 to 9999 pulses per minute 72 X 72 RC2100 775,000
• Input Type : Voltage pluse 3 - 30VDC (sensor PNP/NPN)
• Input voltage : 90 - 270 V AC/DC
• Sensor type : PNP / NPN 48 X 96 RC100 845,000
(sensor PNP)
• Counter & Totaliser
• LED display , 6 digits
• Range : 999999 counts 36 X 72 XC410 690,000
• Input Speed : a) 0 to 20Hz, b) 0 to 1kHz
• Input Type : Voltage pluse 3 - 30VDC
• Input voltage : 90 - 270 V AC/DC, 24VAC/DC
• Sensor type : PNP, NPN

• Counter
• LCD display , 8 digits
• Range : 99999999 counts 24 X 48 LXC900V 315,000
• Input Speed : a) 14Hz, b) 100Hz
• Input Type : 24 - 260 VAC
• Input voltage : baƩery powered

• Counter with setpoint


• LCD display , 4 digits
• Modes : On delay / Interval delay / Auto reset
• Range : 9999 counts 72 X 72 XC22B-4 1,150,000
• Input Speed : a) 0 - 30Hz, b) 0 - 5kHz
• Input Type : Voltage pluse 3 - 30VDC
• Input voltage : 230VAC, 50Hz
• Sensor type : PNP, NPN
• Output contact : 2 C/O (DPDT)

16
TEMPERATURE CONTROLS
PANEL MOUNTING

> Digital Temperature Controls


Picture DescripƟon Type Price (Rp)
• LED Single display , 3 digits
• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF TC513BX 440,000
• Input sensor type :
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

• LED Dual display , 3 digits


• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC533BX 520,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC
• Size : 48 X 48 X 76mm

• LED Dual display , 4 digits


• Dual set point
• Special funcƟons : Heat-Cool PID, Dwell Ɵmer
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC544B 650,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Auxiliary output : 1 (Relay)
• Alarm modes : DeviaƟon, absolute
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

• LED Dual display , 4 digits


• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC538BX 550,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

17
TEMPERATURE CONTROLS
PANEL MOUNTING

> Digital Temperature Controls


Picture DescripƟon Type Output Price (Rp)
• Advanced PID controller, Covers most applicaƟons PID500-0-0-00 Out 1 : relay 1,480,000
• LED Dual display , 4 digits Out 2 : relay
• Fuatures :
> Universal input, Auto tune, Selectable lower display, PID500-1-0-00 Out 1 : SSR 1,580,000
> Single point ramp-soak, Heat-Cool PID, SoŌ start, Auto/Manual mode Out 2 : relay
• Input sensor type :
> Thermocouple ( J,K,T,R,S,C,E,B,N,L,U,W ) PID500-2-0-00 Out 1 : 4-20mA 1,580,000
PID500 > RTD ( PT100 ) Out 2 : relay
( size : 48X48X110 ) > Singnal Input (DC) : -5 to 56mV, 0 - 10V, 0 - 20mA
• Output Control : PID500-3-0-00 Out 1 : 0-10V 1,550,000
> Relay or SSR Out 2 : relay
> Current : 0/4 to 20mA ( max load 500E )
> Voltage : 0 - 50/10VDC ( max load 10K )
• Auxiliary output : 2 (Relay or SSR drive voltage) PID110-0-0-00 Out 1 : relay 1,350,000
• Mode : Set poit or Alarm mode Out 2 : relay
• Alarm modes : DeviaƟon, Absolute, Hight, Low, Band, Sensr break
• Control acƟon : PID or ON-OFF PID110-1-0-00 Out 1 : SSR 1,510,000
• Input voltage : 85 - 270 V AC/DC, 50/60Hz Out 2 : relay

PID110-2-0-00 Out 1 : 4-20mA 1,750,000


Out 2 : relay
PID110
( size : 48X98X85 ) PID110-3-0-00 Out 1 : 0-10V 1,657,000
Out 2 : relay

> Cooling Controlles


Picture DescripƟon Type Price (Rp)
• Chiller Controller, Deforst management, Hight & Low alarm
• LED Single display , 3 digits
• Display oīset : -19.9 to 20.0 ϶C/F CH403-1 400,000
• Single set point
• Control Modes : ON-OFF
• Input sensor type : NTC
• Output Control : Relay
• Alarm output : 2 (Relay or SSR )
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Relay acƟon : Heat & Cool mode
• Size : 36 X 72mm

18

You might also like