■ MEMBER NAME : 1C1(33)
1. General Information
(3) γc : 1.500
(4) γs : 1.150
(5) αcc : 0.850
2. Material
3. Section
(1) Foundation
ㆍ Depth : 1,100mm
ㆍ Cover : 50.00mm
(2) Column Section
ㆍ Shape of Column : Rectangle
ㆍ Section : 600x600mm
4. Rebar
(1) Direction Y
ㆍ Layer 1 : P20@200 (As = 1,571mm²)
(2) Direction X
ㆍ Layer 1 : P20@200 (As = 1,571mm²)
http://www.midasuser.com
1/8
MIDAS Information Technology Co., Ltd
5. Foundation
(1) Foundation Size
ㆍ Lx : 4.000m
ㆍ Ly : 4.000m
ㆍ fe : 300KPa
6. Design Forces
(1) Service Load ( by Load Combinations )
(2) Ultimate Load ( by Load Combinations )
http://www.midasuser.com
2/8
MIDAS Information Technology Co., Ltd
(3) Surcharge Load & Self Weight
Considered ‐ ‐ ‐
4,000
2,000 2,000
y
2,000
4,000
Y1
2,000
X1
1,100
7. Check Soil Capacity
(1) Calculate service soil stress (KPa)
ㆍ qs,top‐left =276 qs,top‐right =269
ㆍ qs,bot‐left =274 qs,bot‐right =267
ㆍ qs,max =276 fe =300
ㆍ qs,max / fe =0.920 → O.K
http://www.midasuser.com
3/8
MIDAS Information Technology Co., Ltd
(2) Calculate ultimate soil stress (KPa)
ㆍ qu,top‐left =391 qu,top‐right =381
ㆍ qu,bot‐left =388 qu,bot‐right =378
ㆍ qu,max =391 qu,min =378
8. Calculate Moment Effective Depth
(1) Direction X = 1,040mm (for MEdy)
(2) Direction Y = 1,020mm (for MEdx)
9. Check Moment Capacity ( Direction X )
(1) Calculate required area of reinforcement
ㆍ K = MEd / ( bd2 fck) = 0.0189
ㆍ K' = 0.598δ ‐ 0.18δ2 ‐ 0.21 = 0.208
ㆍ z = min[ d(0.5+0.5 1‐3.53K ), 0.95d ] = 988mm
ㆍ (Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
ㆍ As,req = f z = 1,485mm²
yd
(2) Calculate limit of reinforcement area
ㆍ fctm = 0.3 fck 2/3 = 2.565MPa
0.26 fctm bd
ㆍ As min = max[ , 0.0013bd ] = 1,701mm²
fyk
ㆍ As max = 0.04 Ac = 44,000mm²
(3) Check area of tensile reinforcement
ㆍ As > As,req → O.K
ㆍ As < As,min → N.G
(4) Calculate moment capacity at the column face
ㆍ MEdy =510kN∙m MRdy =540kN∙m
ㆍ MEdy / MRdy =0.945 → O.K
http://www.midasuser.com
4/8
MIDAS Information Technology Co., Ltd
10. Check Moment Capacity ( Direction Y )
(1) Calculate required area of reinforcement
ㆍ K = MEd / ( bd2 fck) = 0.0195
ㆍ K' = 0.598δ ‐ 0.18δ2 ‐ 0.21 = 0.208
ㆍ z = min[ d(0.5+0.5 1‐3.53K ), 0.95d ] = 969mm
ㆍ (Reference of 0.95d is 'The Concise Eurocode' 2006)
MEd
ㆍ As,req = f z = 1,502mm²
yd
(2) Calculate limit of reinforcement area
ㆍ fctm = 0.3 fck 2/3 = 2.565MPa
0.26 fctm bd
ㆍ As min = max[ , 0.0013bd ] = 1,734mm²
fyk
ㆍ As max = 0.04 Ac = 44,000mm²
(3) Check area of tensile reinforcement
ㆍ As > As,req → O.K
ㆍ As < As,min → N.G
(4) Calculate moment capacity at the column face
ㆍ MEdx =506kN∙m MRdx =529kN∙m
ㆍ MEdx / MRdx =0.956 → O.K
11. Calculate Shear Effective Depth
(1) Direction X = 1,040mm (for VEdx)
(2) Direction Y = 1,020mm (for VEdy)
http://www.midasuser.com
5/8
MIDAS Information Technology Co., Ltd
12. Calculate one‐way shear (Direction X)
(1) Calculate ratio of shear capacity
ㆍ k = min [ 1 + 200/d , 2.0] = 1.439
ㆍ ρl = min[ Asl / bw d, 0.02 ] = 0.00151
ㆍ CRd,c = 0.18 / γc = 0.120
ㆍ VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 1,118kN
ㆍ VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 1,256kN
ㆍ VRdx = max[ VRdx1 , VRdx2 ] = 1,256kN
ㆍ VEdx = 956kN
ㆍ VEdx / VRdx =0.761 → O.K
13. Check One‐Way Shear ( Direction Y )
(1) Calculate ratio of shear capacity
ㆍ k = min [ 1 + 200/d , 2.0] = 1.443
ㆍ ρl = min[ Asl / bw d, 0.02 ] = 0.00154
ㆍ CRd,c = 0.18 / γc = 0.120
ㆍ VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 1,107kN
ㆍ VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 1,237kN
ㆍ VRdy = max[ VRdy1 , VRdy2 ] = 1,237kN
ㆍ VEdy = 979kN
ㆍ VEdy / VRdy =0.791 → O.K
http://www.midasuser.com
6/8
MIDAS Information Technology Co., Ltd
14. Check Two‐Way Shear
(1) Calculate Shear at Face of Column
ㆍ U = 2,400mm
ㆍ a = (ex / by) 2
ㆍ b = (ey / bx) 2
ㆍ β = 1+1.8 a+b = 1.027
β NEd
ㆍ νEd = U d = 2.556MPa
ㆍ fcd = αcc fck / γc = 14.17MPa
ㆍ νRd,max = 0.5ν fcd = 3.825MPa
ㆍ νEd / νRdMax =0.668 → O.K
(2) Calculate Shear at Distance‐2d
ㆍ U = 0.000mm
ㆍ β = 1+1.8 a+b = 1.448
ㆍ νEd = β VEd,red / Ud = 0.000MPa
ㆍ k = min [ 1 + 200/d, 2.0] = 1.441
ㆍ ρl = min[ ρly ρlz , 0.02 ] = 0.00153
ㆍ νRd,1 = CRd,c k (100 ρl fck) 1/3 + k1 σcp = 0.270 MPa
ㆍ νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.303 MPa
ㆍ νRd = max[ νRd,1 , νRd,2 ] = 0.303 MPa
ㆍ νEd / νRd =0.000 → O.K
(3) Calculate Shear at Distance‐d
ㆍ U = 8,872mm
ㆍ β = 1.010
ㆍ νEd = β VEd,red / Ud = 0.418MPa
ㆍ νRd,1 = CRd,c k (100 ρl fck) 1/3 x (2d/a) = 0.540 MPa
ㆍ νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.605 MPa
ㆍ νRd = max[ νRd,1 , νRd,2 ] = 0.605 MPa
ㆍ νEd / νRd =0.690 → O.K
http://www.midasuser.com
7/8
MIDAS Information Technology Co., Ltd
15. Check Rebar
(1) X Direction
ㆍ As,min =1,701mm² As,max =44,000mm²
ㆍ As = 1,571 (P20@200) > As,req = 1,485mm² → O.K
ㆍ sx = 200mm < sMax. = 400mm → O.K
(2) Y Direction
ㆍ As,min =1,734mm² As,max =44,000mm²
ㆍ As = 1,571 (P20@200) > As,req = 1,502mm² → O.K
ㆍ sy = 200mm < sMax. = 400mm → O.K
http://www.midasuser.com
8/8