You are on page 1of 3

GRAFICA ESTACION DE BOMBEO

Q(l/s) Q(m^3/s) HB
0 0 52
3 0.003 52.2711905
6 0.006 53.084762
9 0.009 54.4407145
12 0.012 56.339048
15 0.015 58.7797626
18 0.018 61.7628581
21 0.021 65.2883346
Tabla4 Curva Resistente
24 0.024 69.3561921

HB1=25-(70000*(Q^2))
BOMBA 1
Q(l/s) Q(m^3/s) HB1
0 0 25
3 0.003 24.37
6 0.006 22.48
9 0.009 19.33
12 0.012 14.92
15 0.015 9.25
18 0.018 2.32
Tabla5 Bomba 1
HB2=47-(100000*(Q^2))
BOMBA 2
Q(l/s) Q(m^3/s) HB2
0 0 47
3 0.003 46.1
6 0.006 43.4
9 0.009 38.9
12 0.012 32.6
15 0.015 24.5
18 0.018 14.6
21 0.021 2.9
Tabla6 Bomba 2

HB3=68-(2000000*(Q^2))
BOMBA 3
Q(l/s) Q(m^3/s) HB3
0 0 68
1 0.001 66
2 0.002 60
3 0.003 50
4 0.004 36
5 0.005 18
Tabla7 Bomba 3

HB4=78-(21667*(Q^2))
BOMBA 4
Q(l/s) Q(m^3/s) HB3
0 0 78
3 0.003 77.804997
6 0.006 77.219988
9 0.009 76.244973
12 0.012 74.879952
15 0.015 73.124925
18 0.018 70.979892
21 0.021 68.444853
Tabla8 Bomba 4
HB5=72-(235000*(Q^2))
BOMBA 5
Q(l/s) Q(m^3/s) HB3
0 0 72
3 0.003 69.885
6 0.006 63.54
9 0.009 52.965
12 0.012 38.16
15 0.015 19.125
16 0.016 11.84
17 0.017 4.085
Tabla9 Bomba 5

CURVAS (CARACTERÍSTICAS - RESISTENTE)


90

80

70

60 RESISTENTE
Altura (mca)

BOMBA1
50
BOMBA2
40
BOMBA 3
30 BOMBA 4
20 BOMBA 5

10 P.FUNCIONAMIENTO

0
0 5 10 15 20 25 30
Caudal (litros / segundo)