You are on page 1of 12
Hanyounc nut HY-4500S/4700S/5000 Analog indication temperature controller * Proportional control or ON/OFF control + Simple temperature setting * Built-in auxiliary output (HY-4700) * Plug in type (convenient repairing, inspecting and exchanging! * Burn out function (output OFF with sensor break) * Control action does not get infiuenced even with the break down of indicator &» Suffix code Model Code Description AY TEDL Cr Anaog indication temperature contoter ~~ a8008 || Det X 8 Dimension | 47003 |! 961W) X 96(H) (auxiliary output: LM) 5000 | | aw) X 72H) emg Fi ‘ON/OFF control (2 postion conto) P| Proportional control K < thermocouple J J thermocouple R R thermecouple Input [D: |[Resistanee Temperature DetetonTD) KPHIOO P Resistance Temperature Detector RTD) Pt100 94lEC) v i= 5v0C lc! 4-20 a 0C M Relay Control output c ‘urent output (4 = 20 98 DC) 85R (12 V DC voliage pulse output) N NONE ‘Sub output) ° Low action (apply ony wih he mel HY~700) P “igh action w Low/High action convo! operat R_| Reverse action (heating contra) D | direct action (coating conto) Range code Select the standard range code 185 Temperature Controller & Specification Input Thermocouple KR RTO PHO O, K Pt100 2(139.6 Q when temperature is 100 C) DC voltage input 1-5 VDC, 4- 20 ADC Input impedance ‘Mlwable signal source resistance Allowable wiring resistance Allowable Input voltage Thermocouple and DC voltage inputV) : approx. 1 Ma Thermocouple (100 9 maxl, DC vottagel2 KO max) RTD 10 9 max. (but resistances among 3 wires should be same) Within +10 V (thermocouple, RTD, DC voltage) oid junction compensation err performance #2060 ~ 500) Display accuracy 42% of FS +1 Digit Insulation resistance 20 0 min (500 V DC) Dielectric strength 2,000 V AC, 60/60 He, for tin, between the diferent recharging pt from each other) Control function and output Control type Control action Range setting Proportional band Manual reset (M.R) Proportional cycle Proportional control, ON/OFF contol (selected by the compostion of suffix code) Reverse action or direct action (selected by composition of suffix code) Same as the input range chart 11> 10% of FS (HY-8500 varie Model HY=A700, and HY-5000 are fed with 3% ol FS) #10 % of M.Vlamount of output) Approx. 25 ~ 30 sectrelay cutputl, approx. 2 ~ 4 seciSSR output) Hysteresis Fixed to approx. 2 % of FS, (ON/OFF control) Input signal break detection When exceeding 10 °C from the range limit, output becomes OFF, Auxiliary output (LM) Only with the Model HY=4700, High, low, high/low action (refer to sufix code) ‘Auniary output seing range approx. 50 ‘0 regarding the main setting (400 ‘G range standard) Auxiliary output hysteresis, 10 fixed @ Output contro) |_Relay output | Contact: 1 250 V AC. 3 A (esistve load) control SSR Approx. 12 V DC (resistive load min 800 ©) output Current 4 = 20 m DClresistive load max 600 9) Sul output M Relay Oniy with Model HYMA7ON. pontact 116, 250 V AC 3 A (resistive nad) 186 Hanyounc nut General specification HY-45008/4700S/5000 Power Supply Voltage Voltage fluctuation 110/220 V AC 50/60 He £10 % of power supply voltage Power consumption 3 VA max Ambient temperature | 0 - 60 T Ambient humidity | 35 ~ 85 % RH (withou! dew condensation) Slorage temperature | -25 ~ 65 Vibration resistance 10 ~ 55 He, peak amplitude 0.76 nn, for 1 hr each in 3 axis direction ‘Shock resistance 300 %, direction to 6 each 3 times Weight HY-5000 : 450 g, HY-4500S : 600 9, HY-4700S : 800 Range and input code chart HY=45008, HY=47008 HY-5000 eal Input Range(t) Input Range() 1 P00 80 ~ 50 PrI00 ~50 ~ 50 —3 | Pri00@ =50 ~ 100 Pr100 9 -0 ~ 100 5 P1100 @ o~ 100 K, Pr100 @ o~ 200 Fi - - K, Prt00 @ 0 ~ 300 “7 | «prooo 0 ~ 200 x, Pri00 9 0 ~ 400 _8 | Kk ptioo 0 ~ 300 K 0 ~ 600 8 J, PUOO 9 0 ~ 400 K 0 ~ 800 “10 | K 0 600 K o~ 1200 1 K 0~ 800 5 = 13 K o~ 1200 - = 14 R 0 ~ 1600 = = &e Dimension and panel cutout (Unit : mm) HY-45008, 4700S © Dimension © Panel cutout os 21 125 = 3. | i 120 187

You might also like