You are on page 1of 1

LEGEND:

PINLIGHT (7 WATTS, 4"-6" ~)

DROPLIGHT

LIGHTING / POWER PANEL BOX

CONVENIENCE OUTLET

S ONE GANG SWITCH


S
TWO-GANG SWITCH

S THREE-GANG SWITCH

TELEPHONE OUTLET (4C/22)

TV CABLE OUTLET (RG-6) / ANTENNA

AS SMOKE DETECTOR

GENERAL NOTES:
1. The electrical works shall be done in accordance with the
provisions of the latest edition of the Philippine Electrical
Code, the laws and ordinances of the local enforcing
authority, and the rules and regulations of the local power
utility companies.
2. The entire electrical works shall be directly under the
supervision of a duly registered Electrical Engineer.
3. All materials to be used shall be of the approved type for its
purpose and location.
4. The power service to be supplied shall be 220 volts,
single-phase, two-wire, 60 hertz.
5. Unless otherwise specified in the plans, the minimum size of

lighting and control leads.


6. All electrical installations shall be concealed from view by
installing conductors inside conduits and receways.
7. All conduit runs embedded in concrete, above drop ceiling and
double wall partitions shall be EMT pipe or approved equal. All
conduit runs for feeder lines shall be EMT or approved equal.
8. All panel boards shall be dead front and installed in such a
way that the topmost circuit breaker shall be accessible to a
man of average height.
9. Adequate system of grounding shall be provided in accordance
with the provision of the Philippine Electrical Code.
10. Pull boxes, although not indicated in the plans shall be
A PANEL BOARD DIAGRAM provided for ease in wire pulling.

E 1 SCALE: 1:100 MTS

REGISTERED OWNER: PROJECT NAME SHEET CONTENTS: REV DESCRIPTION DATE DRAWING NO.
THESE DRAWINGS AS INSTRUMENT OF SERVICE 1 - 072018
ARE THE PROPERTY AND DOCUMENTS OF THE ALAMPAY RESIDENCE SCHEDULE OF LOADS

E1
PANEL BOARD DIAGRAM 2 - 112018
DESIGNER. IT SHALL BE UNLAWFUL FOR ANY ENGINEER
PERSON WITHOUT THE WRITTEN CONSENT OF 3
THE DESIGNER OR AUTHORS OF SAID REG NO. PTR NO. LOCATION
CONRAD & MARGAUX ALAMPAY - - -
DOCUMENTS TO DUPLICATE OR COPY SAID PLACE: DESIGN BY:
SIGNATURE - - - SCALE 1:100
INSTRUMENTS. DATE: APPROVED BY: 20 DERBY ST. WHITE PLAINS, QUEZON CITY, MANILA
TIN: CHECKED BY: - - - DRAWN BY RCJ