You are on page 1of 134

20 LEVEL OF

DEVELOPMENT

13
SPECIFICATION
Draft 1 A p ril, 1 9 , 2 0 1 3

100
400

35
00

0 2
300
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Model
Version: DRAFT 2013
Development Version: DRAFT 2013

Specification
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Contents
Level of Development (LOD) Specification Introduction .................................................................................................. 7
A – SUBSTRUCTURE .......................................................................................................................................................... 11
A10 – Foundations ............................................................................................................................................................ 11
A1010 – Standard Foundations ..................................................................................................................................... 11
See A10 – Foundations and A1010 – Standard Foundations .............................................................................................. 12
See A10 – Foundations and A1010 – Standard Foundations .............................................................................................. 13
A1020 – Special Foundations ........................................................................................................................................ 13
See A10 – Foundations and A1020 – Special Foundations ................................................................................................. 13
A20 – Subgrade Enclosures .............................................................................................................................................. 14
A2010 – Walls for Subgrade Enclosures ....................................................................................................................... 15
A40 – Slabs-on-Grade ....................................................................................................................................................... 15
A4010 – Standard Slabs-on-Grade ............................................................................................................................... 16
A4020 – Structural Slabs-on-Grade ............................................................................................................................... 16
See A40 – Slabs-on-Grade ................................................................................................................................................... 16
B – SHELL ............................................................................................................................................................................ 17
B10 – Superstructure ......................................................................................................................................................... 17
B1010 – Floor Construction ........................................................................................................................................... 17
B20 – Exterior Vertical Enclosures .................................................................................................................................... 29
B2010 – Exterior Walls .................................................................................................................................................. 29
B2020 – Exterior Windows............................................................................................................................................. 32
B2050 – Exterior Doors and Grilles ............................................................................................................................... 33
B2070 - Exterior Louvers and Vents .............................................................................................................................. 35
B2080 - Exterior Wall Appurtenances ............................................................................................................................ 35
B2090 – Exterior Wall Specialties .................................................................................................................................. 36
B30 – Exterior Horizontal Enclosures ................................................................................................................................ 36
B3010 – Roofing ............................................................................................................................................................ 36
B3020 – Roof Appurtenances ........................................................................................................................................ 37
B3040 – Traffic Bearing Horizontal Enclosures ............................................................................................................. 38
B3060 – Horizontal Openings ........................................................................................................................................ 38
B3080 – Overhead Exterior Enclosures ........................................................................................................................ 39
C – INTERIORS .................................................................................................................................................................... 40
C10 – Interior Construction................................................................................................................................................ 40
C1010 – Interior Partitions ............................................................................................................................................. 40
Graphical representation with specific identity and parametric data. ............................................................................ 42
C1020 – Interior Windows.............................................................................................................................................. 42
C1030 – Interior Doors................................................................................................................................................... 44
C1040 – Interior Grilles and Gates ................................................................................................................................ 46
C1060 – Raised Floor Construction ............................................................................................................................... 47

2
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1070 – Suspended Ceiling Construction ..................................................................................................................... 47


C1090 – Interior Specialties ........................................................................................................................................... 49
C20 – Interior Finishes ...................................................................................................................................................... 52
C2010 – Wall Finishes ................................................................................................................................................... 53
C2020 – Interior Fabrications ........................................................................................................................................ 54
C2030 – Flooring ........................................................................................................................................................... 54
C2040 – Stair Finishes ................................................................................................................................................... 56
C2050 – Ceiling Finishes ............................................................................................................................................... 57
C2090 – Interior Finish Schedules ................................................................................................................................. 58
D – SERVICES...................................................................................................................................................................... 59
D10 – Conveying ............................................................................................................................................................... 59
D1010 – Vertical Conveying Systems ........................................................................................................................... 59
D1030 – Horizontal Conveying ...................................................................................................................................... 60
D1050 – Material Handling ............................................................................................................................................ 60
D1080 – Operable Access Systems .............................................................................................................................. 62
D20 – Plumbing ................................................................................................................................................................. 63
D2010 – Domestic Water Distribution ............................................................................................................................ 63
D2020 – Sanitary Drainage............................................................................................................................................ 67
D2030 – Building Support Plumbing Systems ............................................................................................................... 71
D2050 – General Service Compressed-Air ................................................................................................................... 75
D2060 – Process Support Plumbing Systems ............................................................................................................... 75
D30 – HVAC ...................................................................................................................................................................... 78
D3010 – Facility Fuel Systems ...................................................................................................................................... 78
D3020 – Heating Systems ............................................................................................................................................. 82
D3030 – Cooling Systems ............................................................................................................................................. 85
D3050 – Facility HVAC Distribution Systems ................................................................................................................ 89
D3060 – Ventilation ........................................................................................................................................................ 92
D3070 – Special Purpose HVAC Systems .................................................................................................................... 95
D40 – Fire Protection ......................................................................................................................................................... 96
D4010 – Fire Suppression ............................................................................................................................................. 96
D4030 – Fire Protection Specialties .............................................................................................................................. 98
D50 – Electrical ............................................................................................................................................................... 100
D5020 – Electrical Service and Distribution................................................................................................................. 105
D5030 – General Purpose Electrical Power ................................................................................................................ 110
D5040 – Lighting .......................................................................................................................................................... 111
D5080 – Miscellaneous Electrical Systems ................................................................................................................. 114
D60 – Communications ................................................................................................................................................... 117
D6010 – Data Communications ................................................................................................................................... 117
D6020 – Voice Communications ................................................................................................................................. 117
D6030 – Audio-Video Communication ......................................................................................................................... 117
D6060 – Distributed Communications and Monitoring ................................................................................................ 117
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D6090 – Communications Supplementary Components ............................................................................................. 117


D70 – Electronic Safety and Security .............................................................................................................................. 117
D7010 – Access Control and Intrusion Detection ........................................................................................................ 117
D7030 – Electronic Surveillance .................................................................................................................................. 117
D7050 – Detection and Alarm ...................................................................................................................................... 117
D7070 – Electronic Monitoring and Control ................................................................................................................. 117
D7090 – Electronic Safety and Security Supplementary Components ....................................................................... 117
D80 – Integrated Automation........................................................................................................................................... 117
D8010 – Integrated Automation Facility Controls ........................................................................................................ 117
E – EQUIPMENT & FURNISHINGS ................................................................................................................................... 118
E10 – Equipment ............................................................................................................................................................. 118
E1010 – Vehicle and Pedestrian Equipment ............................................................................................................... 118
E1030 – Commercial Equipment ................................................................................................................................. 118
E1040 – Institutional Equipment .................................................................................................................................. 120
E1060 – Residential Equipment .................................................................................................................................. 121
E1070 – Entertainment and Recreational Equipment ................................................................................................. 121
E1090 – Other Equipment ........................................................................................................................................... 122
E20 – Furnishings ............................................................................................................................................................ 123
E2010 – Fixed Furnishings .......................................................................................................................................... 123
E2050 – Movable Furnishings ..................................................................................................................................... 124
F – SPECIAL CONSTRUCTION & DEMOLITION ............................................................................................................. 125
F10 – Special Construction ............................................................................................................................................. 125
F1010 – Integrated Construction ................................................................................................................................. 125
F1020 – Special Structures.......................................................................................................................................... 125
F1030 – Special Function Construction ....................................................................................................................... 125
F1050 – Special Facility Components ......................................................................................................................... 125
F1060 – Athletic and Recreational Special Construction ............................................................................................ 125
F1080 – Special Instrumentation ................................................................................................................................. 125
F20 – Facility Remediation .............................................................................................................................................. 125
F2010 – Hazardous Materials Remediation ................................................................................................................ 125
F30 – Demolition ............................................................................................................................................................. 125
F3010 – Structure Demolition ...................................................................................................................................... 125
F3030 – Selective Demolition ...................................................................................................................................... 125
F3050 – Structure Moving............................................................................................................................................ 125
G – BUILDING SITEWORK ................................................................................................................................................ 126
G10 – Site Preparation .................................................................................................................................................... 126
G1010 – Site Clearing ..................................................................................................................................................... 126
G1020 – Site Elements Demolition .............................................................................................................................. 126
G1030 – Site Element Relocations .............................................................................................................................. 126
G1050 – Site Remediation ........................................................................................................................................... 126
4
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G1070 – Site Earthwork ............................................................................................................................................... 126


G20 – Site Improvements ................................................................................................................................................ 127
G2010 – Roadways ..................................................................................................................................................... 127
G2020 – Parking Lots .................................................................................................................................................. 127
G2030 – Pedestrian Plazas and Walkways ................................................................................................................. 127
G2040 – Airfields ......................................................................................................................................................... 127
G2050 – Athletic, Recreational, and Playfield Areas ................................................................................................... 127
G2060 – Site Development .......................................................................................................................................... 127
G2080 – Landscaping .................................................................................................................................................. 127
G30 – Liquid and Gas Site Utilities .................................................................................................................................. 127
G3010 – Water Utilities ................................................................................................................................................ 127
G3020 – Sanitary Sewerage Utilities ........................................................................................................................... 127
G3030 – Storm Drainage Utilities ................................................................................................................................ 127
G3050 – Site Energy Distribution ................................................................................................................................ 127
G3060 – Site Fuel Distribution ..................................................................................................................................... 127
G3090 – Liquid and Gas Site Utilities Supplementary Components ........................................................................... 127
G40 – Electrical Site Improvements ................................................................................................................................ 128
G4010 – Site Electric Distribution Systems ................................................................................................................. 129
G4050 – Site Lighting .................................................................................................................................................. 130
G5010 – Site Communications Systems ..................................................................................................................... 131
G9010 – Tunnels ......................................................................................................................................................... 132
APPENDIX .......................................................................................................................................................................... 133
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Acknowledgements
Thanks to all individuals and organizations who reviewed and contributed to this work, and to the following industry
association representatives and co-chairs of the major discipline subgroups who made this document possible:

Overall co-chairs
Jan Reinhardt, AIA, PE, Adept Project Delivery
Jim Bedrick, FAIA, AEC Process Engineering

Domain-Specific Content
Design Construction

Structures Will Ikerd, Ikerd Consulting David Merrifield, Alpha Steel

Exterior Skin James Vandezande, HOK Walt Cichonski, L F Driscoll

Interior Construction Ron Dellaria, RA, CSI, Astorino Brian Filkins, Mortenson

Building Services Murat Karakas, Arup David Francis, Southland


Aaron Lawson, Gould Electric

Industry association representatives


Dmitri Alferieff, Associated General Contractors
Michael Bomba, Esq., American Institute of Architects

Overall editing
Marisa Gerdano, Associated General Contractors

Nothing contained in this work shall be considered to be the rendering of legal advice for specific cases, and readers are
responsible for obtaining such advice from their own legal counsel. This work and any forms herein are intended solely for
educational and informational purposes.

Qualifications Based Selection of Contractors © 2013 by BIMForum.

No portions of this work may be reproduced or displayed without the express written permission of the copyright holders. All
rights reserved.

6
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Level of Development (LOD) Specification Introduction

1 Overview
1
The Level of Development (LOD) Specification is a reference that enables practitioners in the AEC Industry to specify
and articulate with a high level of clarity the content and reliability of Building Information Models (BIMs) at various stages
in the design and construction process. The LOD Specification utilizes the basic LOD definitions developed by the AIA for
2 3
the AIA G202-2013 Building Information Modeling Protocol Form and is organized by CSI Uniformat 2010 . It defines
and illustrates characteristics of model elements of different building systems at different Levels of Development. This
clear articulation allows model authors to define what their models can be relied on for, and allows downstream users to
clearly understand the usability and the limitations of models they are receiving.
The intent of the Specification is to help explain the LOD framework and standardize its use so that it becomes more
useful as a communication tool. It does not prescribe what Levels of Development are to be reached at what point in a
project but leaves the specification of the model progression to the user of this document. To accomplish the document’s
intent, its primary objectives are:

To help teams, including owners, to specify BIM deliverables and to get a clear picture of what will be included in
a BIM deliverable

To help design managers explain to their teams the information and detail that needs to be provided at various
points in the design process

To provide a standard that can be referenced by contracts and BIM execution plans.

2 Background
The BIMForum initiated the development of this LOD Specification and formed a working group comprising contributors
from both the design and construction sides of the major disciplines. The working group first interpreted the AIA’s basic
LOD definitions for each building system, and then compiled examples to illustrate the interpretations. Because BIM is
being put to an ever increasing number of uses, the group decided that it was beyond the initial scope to address all of
them. Instead, the specifications were developed to address model element geometry, with three of the most common
uses in mind – quantity take-off, 3D coordination and 3D control and planning. The group felt that in taking this approach
the interpretations would be complete enough to support other uses.

3 Levels of Development
The Level of Development (LOD) framework addresses several issues that arise when a BIM is used as a communication
or collaboration tool, i.e., when someone other than the author extracts information from it:

2
AIA Contract Document G202-2013, Building Information Modeling Protocol Form is part of a new series of
digital practice documents the AIA will be publishing in in conjunction with the AIA National Convention in June
2013. For general information on the documents and downloadable drafts that were published in August 2012 as
part of a public comment period see www.aia.org/digitaldocs. Once the final documents are released, samples
will be available for download through the same site.
3 TM
UniFormatTM Numbers and Titles used in this publication are from UniFormat , published by CSI and
Construction Specifications Canada (CSC), and are used with permission from CSI. For a more in-depth
TM
explanation of UniFormat and its use in the construction industry visit www.csinet.org or contact CSI,110 South
Union Street, Suite 100, Alexandria, VA 22314. (800)-689-2900.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

During the design process, building systems and components progress from a vague conceptual idea to a precise
description. In the past there has been no simple way to designate where a model element is along this path.
The author knows, but others often don’t.

It’s easy to misinterpret the precision at which an element is modeled. Hand drawings range from pen strokes on
a napkin to hard lines with dimensions called out, and it’s easy to infer the precision of the drawing from its
appearance. In a model though, a generic component placed approximately can look exactly the same as a
specific component located precisely, so we need something besides appearance to tell the difference.

It is possible to infer information from a BIM that the author doesn’t intend – unstated dimensions can be
measured with precision, assembly information often exists before it’s been finalized, etc. In the past, this issue
has been sidestepped with all-encompassing disclaimers that basically say, “Since some of the information in the
model is unreliable, you may not rely on any of it.” The LOD framework allows the author to clearly state the
reliability of given model elements, so the concept becomes “Since some of the information in the model is
unreliable, you may only rely on it for what I specifically say you can.”

In a collaborative environment, where people other than the model author are depending on information from the
model in order to move their own work forward, the design work plan takes on high importance – it is necessary
for the model users to know when information will be available in order to plan their work. The LOD framework
facilitates this.

The LOD Framework addresses these issues by providing an industry-developed standard to describe the state of
development of various systems within a BIM. This standard enables consistency in communication and execution by
facilitating the detailed definition of BIM milestones and deliverables.

3.1 Level of Development vs. Level of Detail


This Specification uses the concept of Levels of Development rather than Levels of Detail. There are important
differences.
Level of Detail is essentially how much detail is included in the model element. Level of Development is the degree to
which the element’s geometry and attached information has been thought through – the degree to which project team
members may rely on the information when using the model. In essence, Level of Detail can be thought of as input to the
element, while Level of Development is reliable output.

4 LOD Definitions

In 2008, the AIA developed its first set of Level of Development definitions in AIA Document E202 -2008 Building
Information Modeling Protocol. Due to the rapidly evolving nature of the use of BIM, the AIA evaluated the AIA E202–
2008, including the LOD definitions. The result is the updated and reconfigured Digital Practice documents, AIA E203™–
2013, Building Information Modeling and Digital Data Exhibit, AIA G201™–2013, Project Digital Data Protocol Form, and
AIA G202™–2013, Project Building Information Modeling Protocol Form, which are accompanied by a detailed guide
document entitled Guide and Instructions to the AIA Digital Practice Documents. The AIA’s updated Digital Practice
documents include revised LOD definitions.
To help further the standardization and consistent use of the LOD concept, and to increase its usefulness as a foundation
for collaboration, the AIA agreed to allow the BIMForum to utilize its latest LOD definitions in this Specification. The LOD
definitions that are used in this catalog are identical to those to be published in the AIA’s updated Digital Practice
Documents, with two exceptions.
First, the working group identified the need for an LOD that would define model elements sufficiently developed to
facilitate coordination between disciplines – e.g. clash detection/avoidance, layout, etc. The requirements for this level
are higher than those for 300, but not as high as those for 400. Thus it was designated LOD 350. The AIA documents do
not include LOD 350, but the associated Guide and Instructions references it.

8
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Second, while LOD 500 is included in the AIA’s LOD definitions, the working group did not feel it was necessary to further
define and illustrate LOD 500 in this Specification because it relates to field verification. Accordingly the expanded
descriptions and graphical illustrations in this Specification are limited to LOD 100-400.
Fundamental LOD Definitions

LOD 100 The Model Element may be graphically represented in the Model with a symbol or other generic
representation, but does not satisfy the requirements for LOD 200. Information related to the Model Element (i.e.
cost per square foot, tonnage of HVAC, etc.) can be derived from other Model Elements.

LOD 200 The Model Element is graphically represented within the Model as a generic system, object, or
assembly with approximate quantities, size, shape, location, and orientation. Non-graphic information may also be
attached to the Model Element.

LOD 300 The Model Element is graphically represented within the Model as a specific system, object or
assembly in terms of quantity, size, shape, location, and orientation. Non-graphic information may also be
attached to the Model Element.

LOD 350 The Model Element is graphically represented within the Model as a specific system, object, or
assembly in terms of quantity, size, shape, orientation, and interfaces with other building systems. Non-graphic
information may also be attached to the Model Element.

LOD 400 The Model Element is graphically represented within the Model as a specific system, object or
assembly in terms of size, shape, location, quantity, and orientation with detailing, fabrication, assembly, and
installation information. Non-graphic information may also be attached to the Model Element.

LOD 500 The Model Element is a field verified representation in terms of size, shape, location, quantity,
and orientation. Non-graphic information may also be attached to the Model Elements. 4

Example – light fixture:


100 cost/sf attached to floor slabs
200 light fixture, generic/approximate size/shape/location
300 2x4 troffer, specific size/shape/location
350 Lightolier DPA2G12LS232, specific size/shape/location
400 As 350, plus special mounting details, as in a decorative soffit
Glossary
The expanded definitions use the following interpretations of these terms:
Specific: The quantity, size, shape, location, and orientation of the element as designed can be measured directly
from the model without referring to non-modeled information such as notes or dimension call-outs.
Actual: The model element includes all the qualities of a specific element and is representative of the
manufacturer-specific model to be installed or the construction intent of an assembly.
Order of Precedence
The body of this Specification expands on these fundamental definitions as they apply to specific building systems and
sub-systems. In the event of any conflict, more specific expansions take precedence over less specific expansions and
fundamental definitions, e.g. the expanded definitions for C1010 take precedence over those for C10, which in turn take
precedence over the fundamental definitions.
Model Element Author

4
The definitions for LOD 100, 200, 300, 400, and 500 included in this Specification represent the updated
language that appears in the AIA’s most recent BIM protocol document, G202–2013, Building Information
Modeling Protocol Form. The LOD 100, 200, 300, 400 and 500 definitions are produced by the AIA and have
been used by permission. Copyright © 2013. The American Institute of Architects. All rights reserved. LOD 350
was developed by the BIMForum working group. Copyright © 2013. The BIMForum and the American Institute of
Architects. All rights reserved.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

This document does not prescribe who the author of a particular component at a certain LOD should be – the sequence of
responsibility for modeling various systems will vary from one project to another. To accommodate for this variation this
document defers to the concept of Model Element Author (MEA) as defined in the AIA E203-2013: “The Model Element
Author is the entity (or individual) responsible for managing and coordinating the development of a specific Model Element
to the LOD required for an identified Project milestone, regardless of who is responsible for providing the content in the
5
Model Element."

4.1 LOD Definitions Explained


LOD 100, then, corresponds to a conceptual level. For example, in a massing model the interior walls may not yet be
modeled, but we can use the approximate floor area to generate an area-based interior construction cost. Thus the walls
are at LOD 100 – they’re not modeled, but information about them can be obtained from elements that are modeled (the
floors) coupled with other information (area-based cost tables).
To continue with the wall example, a floor plan is often first laid out using generic walls. The walls can now be measured
directly, but the specific wall assemblies aren’t known and the quantity, thickness, and location measurements are
approximate. The walls are now at LOD 200. To step back to the massing model, if generic exterior walls are modeled
and can be measured directly, they are actually at LOD 200, even though there is little detail.
At LOD 300 the wall element is modeled as a specific composite assembly, with information about its framing, wallboard,
insulation if any, etc. The element is modeled at the thickness of the specified assembly, and is located accurately within
the model. Non-geometric information such as fire rating may also be attached as well. This means that it’s not
necessary to model every component of the wall assembly – a solid model element with accurate thickness and location
and with the information usually included in a wall type definition satisfies the requirements of LOD 300.
At LOD 350 enough detail for installation and cross-trade coordination is included. For the wall example, this would
include such things as blocking, king studs, seismic bracing, etc.
LOD 400 can be thought of as similar to the kind of information usually found in shop drawings.

4.1 Caveats
There is no strict correspondence between LODs and design phases. Building systems are developed at different
rates through the design process – for example, design of the structural system is usually well ahead of the design of
interior construction. At an early design phase milestone, the model will include many elements at LOD 200, but will also
include many at LOD 100, as well as some at 300, and possibly even 400.
Similarly, there is no such thing as an “LOD ___ model”. As previously stated, project models at any stage of delivery
will invariably contain elements and assemblies at various levels of development.

5 Updates of This Document


While this document is intended as a reference that can be cited in agreements such as contract and BIM execution
plans, it is recognized that the use of BIM in design and construction is evolving. To accommodate this evolution this
document will be updated periodically in clearly identifiable versions. Initially the target frequency is annually, but that
may change in the future. In addition, interim updates may be issued if needed.
Revision History
4/24/13 Initial draft for public review
__/__/__ Draft Level of Development Specification 2013

5
AIA Document E203-2013 Building Information Modeling and Digital Data Exhibit. Copyright © American
Institute of Architects 2013. All rights reserved. Definition quoted here by permission.
10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

A – SUBSTRUCTURE
A10 – Foundations
100 A written structural narrative is provided without structural elements
modeled. This narrative may reference an architectural mass model
that shows generic building scale and proportion of the foundation.
200 Generic element modeling to include:
Approximate size/shape of foundation element
Structural grids defined in model
300 This LOD includes but is not limited to design level information such
as the engineered size/shape of the foundation.
Specific element modeling to include:
Overall size and geometry of the foundation element
Sloping surfaces or floor depressions
Out to out dimensions of the members
Material strength
Element information defined with notes or 2D details may include:
Rebar
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Chamfers
Rebar and any embedded elements modeled at congested
areas where specified by project BIM manager which is
typically with in a set distance from the area of congestion
Anchor rods
Any permanent shoring or forming structures such as
caissons or void boxes.
400 This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

A1010 – Standard Foundations


See A10 – Foundations
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

A1010.10 – Wall Foundations (Shallow Foundations)


See A10 – Foundations and A1010 – Standard Foundations
100 See A10
200 See A10
300 See A10
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Location of sleeve penetrations
Pour joints
Moisture retarder
Dowels
All elements needed for cross-trade collaboration are to be
modeled.
Additional element modeling for unit masonry foundations include
but are not limited to:
Actual location and shape of structural element
All exposed embeds or reinforcement such as lintels
All penetrations detailed and modeled
Expansion joints

400 Fabrication element modeling to include but not limited to:


Rebar detailing including hooks and lap splices
Dowels
Chamfer
Finish
Coursing for unit masonry defined
Waterproofing

12
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

A1010.30 – Column Foundations (Deep Foundations)


See A10 – Foundations and A1010 – Standard Foundations
100 See A10
200 See A1010
300 Specific element modeling to include:
Approximate bearing depth noted with site and soil
contingencies expected
Top of Pier
Size of Pier
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Actual Top of Pier (TOP) and expected Bottom of Pier
(BOT) modeled per engineers review of site conditions
All elements needed for cross-trade collaboration are to be
modeled
400 Fabrication element modeling to include but not limited to:
Depth to bearing stratum
Penetration into bearing stratum
Locations of lap splices

A1020 – Special Foundations


See A10 – Foundations

A1020.80 – Grade Beams


See A10 – Foundations and A1020 – Special Foundations
100 See A10
200 See A1010
300 See A1010
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Water Stops
Pour joints and sequences required to identify reinforcing
lap spice, scheduling, etc.
Post-tension profile and strands called out with a narrative
or modeled if required by the BIM manager
400 Fabrication element modeling to include but not limited to:
Detailed Post-tensioned components
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

A20 – Subgrade Enclosures


100 A written structural narrative is provided without structural objects
modeled. This narrative may reference an architectural mass model
that shows generic building scale and proportion of the foundation.
200 Generic element modeling to include:
Approximate size/shape of the subgrade enclosure element
Structural grids defined in model
300 This LOD included but is not limited to design intent level information
such as the engineered size/shape of the subgrade enclosure.
Specific element modeling to include:
Overall size and geometry of the subgrade element
Sloping surfaces
Out to out dimensions of the element
Material strength
Element information defined with notes or 2D details may include:
Rebar
Chamfers
Finishes
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Chamfers
Sleeve penetrations
Pour joints
Rebar and any embedded elements modeled at congested
areas where specified by project BIM manager which is
typically with in a set distance from the area of congestion.
Any permanent shoring or forming structures such as void
boxes
Interior finish and/or insulation
Expansion Joints
All elements needed for cross-trade collaboration are to be
modeled
Moisture retarder
Additional element modeling for unit masonry enclosures include but
are not limited to:
Actual location and shape of structural masonry element
All exposed embeds or reinforcement such as lintels
All penetrations detailed and modeled
Expansion joints
400 This element level modeling shall include all information needed to
Fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Fabrication element modeling to include but not limited to:
Rebar detailing including hooks and lap splices
Dowels
Chamfer

14
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Finish
Coursing for unit masonry defined
Waterproofing

A2010 – Walls for Subgrade Enclosures


See A20 – Subgrade Enclosures

A40 – Slabs-on-Grade
100 A written structural narrative is provided without structural objects
modeled. This narrative may reference an architectural mass model
that shows generic building scale and proportion of the slab.
200 Generic element modeling to include:
Generic slab with approximate thickness
Structural grids defined in model
300 This LOD included but is not limited to design intent level information
such as the engineered size/shape of the subgrade enclosure.
Specific element modeling to include:
Overall size, thickness and geometry of the slab-on-grade
Slab Depressions
Edge turn downs
Material strength
Element information defined with notes or 2D details may include:
Rebar
Moisture Retarder
Slab penetrations
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Sleeve penetrations
Pour joints
Control joints
Expansion joints
Water Stops
Rebar and any embedded elements modeled at congested
areas where specified by project BIM manager which is
typically with in a set distance from the area of congestion.
Void boxes
Anchor rods
Moisture retarder
Dowels
Post-tension profile and strands called out with a narrative or
modeled if required by the BIM manager
400 This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Fabrication element modeling to include but not limited to:
Actual slab dimensions and profiles with fully modeled rebar
Post tensioning components
All joints
Water proofing
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Finish

A4010 – Standard Slabs-on-Grade


See A40 – Slabs-on-Grade

A4020 – Structural Slabs-on-Grade


See A40 – Slabs-on-Grade

16
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B – SHELL
B10 – Superstructure
100 A written structural narrative is provided without structural objects
modeled. This narrative may reference an architectural mass model
that shows generic building scale and proportion of the foundation.
200 A written structural narrative is provided without structural objects
modeled. This narrative may reference an architectural mass model
that shows generic building scale and proportion of the foundation.

B1010 – Floor Construction


100 See B10
200 Generic floor model to include
Floor with approximate dimensions
Approximate supporting framing members
Structural grids defined in model

B1010.10 – Floor Structural Frame


Masonry
100 See B10
200 Generic Masonry superstructure to have:
Type of structural masonry system
Defined structural grid
Rough order of magnitude estimate of masonry structure
300 Specific element modeling to include:
Specific sizes of main structural elements modeled per
defined structural grid with correct dimensions.
Rough openings with reinforcement and steel lintels called
out in typical details
Reinforcement and fill called out in 2D
Typical details for small penetrations
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Actual location and shape of structural masonry element
All exposed embeds or reinforcement such as lintels
All penetrations detailed and modeled
Expansion joints

400 Fabrication element modeling to include but not limited to:


Waterproofing
Coursing
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Steel
100 See B10
200 Generic steel superstructure to have:
Type of structural system
Defined structural grid
Rough order of magnitude estimate of steel structure

Steel Framing Columns


100 See B10
200 See B1010 (00)
300 Specific element modeling to include:
Specific sizes of main vertical structural members modeled
per defined structural grid with correct orientation.
Structural steel materials defined in specification’s.
Typical connection details in 2D

350 Actual element modeling to include but not limited to information


needed for cross trade collaboration such as:
Actual elevations and location of member connections
Large elements of typical connections applied to all structural
steel connections such as base plates, gusset plates, anchor
rods, ect.
Any miscellaneous steel members with correct orientation
Any steel structure reinforcement such as web stiffeners,
sleeve penetrations, ect.

400 Fabrication element modeling to include but not limited to:


Welds
Coping of members
Cap pates
Washers, nuts, etc.
All assembly elements
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

18
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Steel Framing Beams


100 See B10
200 See B1010 (00)
300 Specific element modeling to include:
Specific sizes of main horizontal structural members modeled per
defined structural grid with correct orientation, slope and elevation
Element information defined with notes or 2D details may include:
Connection details
Structural steel materials defined
Finishes, i.e. painted, galvanized, etc

350 Actual element modeling to include but not limited to information needed
for cross trade collaboration such as:
Large elements of typical connections applied to all structural steel
connections such as base plates, gusset plates, anchor rods, etc.
Any miscellaneous steel members with correct orientation
Any steel structure reinforcement such as web stiffeners, sleeve
penetrations, etc.

400 Fabrication element modeling to include but not limited to:


Welds
Coping of members
Bent plates, Cap pates, ect.
Bolts, Washers, nuts, etc.
All assembly elements
This element level modeling shall include all information needed to fully
define the fabrication and installation of the element. Additional non-
modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Steel Framing Miscellaneous Members


100 See B10
200 See B1010 (00)
300 Specific element modeling to include:
Specific sizes of main structural members modeled per
defined structural grid with correct orientation.
Structural steel materials defined in specification’s.
Typical connection details in 2D

350 Actual element modeling to include but not limited to information


needed for cross trade collaboration such as:
Actual elevations and location of member connections
Large elements of typical connections applied to all structural
steel connections such as base plates, gusset plates, anchor
rods, etc.
Any miscellaneous steel members with correct orientation
Any steel structure reinforcement such as web stiffeners,
sleeve penetrations, etc.

400 Fabrication element modeling to include but not limited to:


Welds
Coping of members
Cap pates
Washers, nuts, etc.
All assembly elements
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

20
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Steel Framing Bracing Rods


100 See B10
200 See B1010 (00)
300 Specific element modeling to include:
Specific sizes of main structural braces modeled per defined
structural grid
Structural steel materials defined in specifications.
Typical connection details in 2D

350 Actual element modeling to include but not limited to information


needed for cross trade collaboration such as:
Actual elevations and location of member connections
Large elements of typical connections applied to all structural
steel connections such as base plates, gusset plates, anchor
rods, etc.
Any miscellaneous steel members with correct orientation
Any steel structure reinforcement such as web stiffeners,
sleeve penetrations, etc.

400 Fabrication element modeling to include but not limited to:


Welds
Coping of members
Cap pates
Clevis
Bolts, Washers, Nuts, etc.
All assembly elements
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Steel Joist
100 See B10 for additional information
Basic floor loading criteria and geometry would be defined
with a narrative and would include but is not limited to:
o Live
o Dead
o Wind
o Vibration
o Expected depth
200 Generic element modeling to include:
Expected depth
300 Specific element modeling to include:
Joist size, depth, and material with sloping geometry
Spacing and end elevations
Joist seat depth
Element information defined with notes or 2D details may include:
Non-standard joist seat depths and\or sloping joist seat
Member designation, load capacity and deflection criteria
Design loads
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Actual final joist profile locations with panel points
Joist bridging and lateral braces.
Fire protection coating
Any miscellaneous steel pertaining to the joist
Joist seat width
Erection details for installation
Chord and web member section profiles are actually defined
Joist layout in coordination with metal deck fasteners would
be confirmed
Non-standard joist seat depths and\or sloping joist seat
400 Fabrication element modeling to include but not limited to:
Welds
Connection plates
Member fabrication part number
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

22
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Cold-Formed Metal Framing


100 See B10
200 Generic element modeling to include:
Rough architectural masses
Desired member depth
Desired member spacing

300 Specific element modeling to include:


model with specific locations and geometries
Element information defined with notes or 2D details may include:
Member size, depth, and material with sloping geometry
Spacing and end elevations
Design Loads
Deflection Criteria
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Members modeled at any interface with wall edges (top,
bottom, sides) or opening through wall
Members coming out of the plan of walls which includes but
is not limited to kickers, diagonal bracing, etc.
Bridging or straps
400 Fabrication element modeling to include but not limited to:
Welds
Connections
Member fabrication part number
Any part required for complete installation
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Wood Floor Truss


100 See B10
Basic floor loading criteria and
geometry would be defined with a
narrative and would include but is
not limited to:
o Live
o Dead
o Wind
o Vibration
o Expected depth
200 Generic element modeling to include:
Expected depth
Top chord or bottom chord bearing
Truss Orientation

300 Specific element modeling to include:


Truss size, depth, and material
with sloping geometry
Spacing and end elevations
Support locations
Element information defined with notes or
2D details may include:
Member designation, load
capacity and deflection criteria
Design loads

350 Actual element modeling to include but not


limited to information needed for cross
trade collaboration such as:
Actual final truss profile with panel
points.
Bridging and lateral braces.
Fire protection coating
Any miscellaneous framing
pertaining the truss
Erection details for installation
Chord and web member section
profiles are actually defined
Truss layout in coordination with
deck fasteners would be
confirmed
Hold down locations for large
bolts.
400 Fabrication element modeling to include

24
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

but not limited to:


Truss Capacity
Connection plates
Member fabrication part number
This element level modeling shall include
all information needed to fully define the
fabrication and installation of the element.
Additional non-modeled information may
be included into the element. All
connection plates modeled

B1010.20 –Floor Decks, Slabs, and Toppings


Wood Floor Deck
100 See B10
200 See B1010
300 Specific element modeling to include:
Diaphragm load and deflection criteria
Deck orientation
Deck material and thickness
Applicable slopes
Expected Framing member profiles, spacing, and material
Element information defined with notes or 2D details may include:
Deck fasteners
Typical framing details
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Deck edge location
Actual framing member and location per manufacture
All miscellaneous framing including braces, kickers, etc.
Deck openings modeled with support framing around
openings
Point load locations
Actual opening locations and sizes defined
400 Fabrication element modeling to include but not limited to:
All framing accessory and fasteners modeled per expected
installation
Waterproofing
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Metal Floor Deck


100 See B10
200 See B1010
300 Specific element modeling to include:
Diaphragm load and deflection criteria
Deck material and thickness
Expected Framing member profiles, spacing, and material
Opening locations are prescriptively defined with notes for
additional misc. framing
Point load locations
Element information defined with notes or 2D details may include:
Deck fasteners
Typical framing details
Typical weld specifications
Reinforcing
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Deck edge location
Deck splice and end lap locations
Actual deck profile and flute locations per manufacture
All miscellaneous framing including braces, kickers, etc.
Deck openings modeled with support framing
400 Fabrication element modeling to include but not limited to:
All framing accessory and fasteners modeled per expected
installation
Welds
Waterproofing
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

26
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Composite Floor Deck


100 See B10
200 See B1010
300 Specific element modeling to include:
Diaphragm load and deflection criteria
Expected deck material and thickness
Expected Framing member profiles, spacing, material
Opening locations are prescriptively defined with notes for
additional misc. framing
Element information defined with notes or 2D details may include:
Deck fasteners
Typical framing details
Typical weld specifications
Camber
Shear studs
Toppings

350 Actual element modeling to include but not limited to information


needed for cross trade collaboration such as:
Deck edge location
Deck profile and flute locations per manufacture
Deck splice and end lap locations
Actual framing member and location per manufacture
All miscellaneous framing including deck support, deck
closure, shear studs, etc.
Slab openings modeled with support framing around
openings
Point load locations
Slab reinforcing may need to modeled per BIM mangers
request
400 Fabrication element modeling to include but not limited to:
All framing accessory and fasteners modeled per expected
installation
All slab reinforcing
Welds
Waterproofing
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

Concrete
100 See B10
200 Generic concrete superstructure to have:
Type of structural concrete system
Defined structural grid
Approximate geometry (e.g. depth) of structural elements
300 Specific element modeling to include:
Specific sizes and locations of main concrete structural
members modeled per defined structural grid with correct
orientation.
Concrete defined per spec (strength, air entrainment,
aggregate size, etc.).
Element information defined with notes or 2D details may include:
Reinforcing
Post-tension profiles and strand locations
Penetrations for items such as MEP.
Finishes, camber, chamfers, ect.
Typical details
All embeds and anchor rods identified in 2D
350 Actual element modeling to include but not limited to information
needed for cross trade collaboration such as:
Reinforcement called out, modeled if required by BIM
manager, typically only in congested areas.
Pour joints and sequences to help in identifying, reinforcing
lap spice, scheduling, ect.
Expansion Joints
Anchor rods
Post-tension profile and strands called out with a narrative or
modeled if required by the BIM manager.
All embed elements
Elevations and location of elements
Penetrations for items such as MEP
Any permanent forming or shoring components

400 Fabrication element modeling to include but not limited to:


All reinforcement including post tension elements detailed
and modeled
Finishes, camber, chamfer, etc.
This element level modeling shall include all information needed to
fully define the fabrication and installation of the element. Additional
non-modeled information may be included into the element.

28
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B20 – Exterior Vertical Enclosures


100 Narrative containing percentage of materials (e.g. solid vs.
glazed); or solid mass model representing overall building
volume.

B2010 – Exterior Walls


100 See B20
200 Generic wall objects separated by type of material (e.g. brick wall vs.
curtain wall); wall thicknesses and detailed locations still flexible;
mullion spacing may be included as a single-line grid pattern.

300 Composite model assembly with overall thickness that accounts for
veneer, structure, insulation, air space, and interior skin specified for
the wall system. (Refer to LOD350 and LOD400 for individually
modeled elements)
Specification of assembly materials shall be attached to the model
elements as non-graphical information.Penetrations are modeled to
nominal dimensions for major wall openings such as windows, doors,
and large mechanical elements.

350 Dependent on 350 being provided by host objects such as windows,


doors, etc. Headers and jambs must be modeled.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2010.10 – Exterior Wall Veneer


Description: Nonstructural outside face elements of exterior walls. Includes precast concrete, unit masonry,
EIFS, manufactured siding, and stucco.
100 See B20
200 See B2010
300 See B2010
350 Exterior wall veneer modeled as a separate element.
All openings modeled to actual rough dimensions.
Precast concrete panels are individually modeled. Connection
points are specified.

400 All assembly components modeled including, but not limited to


masonry units, reinforcing, flashing, sealants, anchors, and
embeds.

B2010.20 – Exterior Wall Construction


Description: Exterior wall construction including backup systems for wall veneer. May be vertical load bearing.
Includes cast-in-place concrete walls, precast concrete walls, unit masonry walls, metal framed wall systems,
and wood framed wall systems.
100 See B20
200 See B2010
300 See B2010
350 Exterior wall construction modeled as a separate element.
All openings modeled to actual rough dimensions. Headers
and jamb framing are modeled.
Framing, unit masonry, or reinforcement specification included
as non-graphical information.

400 All assembly components modeled including, but not limited to


studs, tracks, masonry units, reinforcing, sheathing, and
insulation.

30
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2010.30 – Exterior Wall Interior Skin


Description: Materials to provide finish or protective covering on inside of face of exterior walls. May include
insulation and vapor retarder.
100 See B20
200 See B2010
300 See B2010
350 Exterior wall interior skin modeled as a separate element.
All openings modeled to actual rough dimensions.
Framing, unit masonry, or reinforcement specification included
as non-graphical information.

400 All assembly components modeled including, but not limited to


studs, tracks, masonry units, reinforcing, sheathing, and
insulation.

B2010.50 – Parapets
Exterior wall construction above plane of roof.
< Use specifications for B2010, B2010.10, B2010.20, and B2010.30. >

B2010.60 – Equipment Screens


Exterior wall construction to screen equipment from public view.
100 See B20
200 See B2010
300 Overall assembly modeled to actual thickness with surface
representation of fenestration condition.

350 Framing member sizing represented in quantity, size, shape,


location and orientation.
Surface area, joint sizing, framing member sizing represented
in quantity, size, shape, location and orientation.

400 Connections are modeled (anchors, embeds, etc.)


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2020 – Exterior Windows


100 See B20
200 Windows approximate in terms of location, size, count and type.
Units can be modeled as a simple, monolithic component; or
represented with simple frame and glazing.
Nominal unit size is provided.

B2020.10 – Exterior Operating Windows


Also includes: B2020.20 - Exterior Fixed Windows; B2020.50 - Special Function Windows
300 Units are modeled based on specified location and nominal size.
Outer geometry of window frame elements and glazing modeled to
within 1/8” [1 mm] precision.
Operation is indicated
Non-graphic information associated with model element:
Aesthetic characteristics (finishes, glass types)
Performance characteristics in narrative, but associated
with element in model (i.e. U-value, wind loading, blast
resistance, structural, air, thermal, water, sound)
Attachment method of window to structure
350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening dimensions
Embed geometry
All connection attachment details
400 Modeled units will meet the minimum requirements up to and
including LOD 350, in addition to the following:
Frame profiles
Glazing sub-components (gaskets)
Attachment components

B2020.20 – Exterior Fixed Windows


[See B2020.10]

B2020.30 – Exterior Window Wall


[See B2020.10]

B2020.50 – Exterior Special Function Windows


[See B2020.10]

32
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2050 – Exterior Doors and Grilles


100 Simple representation of a door unit. Size, count, and location are
approximate.
200
Units can be modeled as a simple, monolithic component; or
represented with simple frame and glazing.
Nominal unit size is provided.

B2050.10 – Exterior Entrance Doors


Exterior personnel door assemblies at main entrances. Includes automatic, revolving, balanced, and other
special operating entrance doors, and sliding storefront wall systems.
100 See B20
200 See B2050
300 Doors and door frames defined by type, hardware; narrative
associated with specific model elements; envelope and space
requirements are represented in model element.
Specific doors, frames and hardware. Hardware set functionality and
types are specified.
350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening is modeled (if applicable)
Major framing elements are modeled at jambs and head
400 Modeled units will meet the minimum requirements of LOD 350, in
addition to the following:

B2050.20 – Exterior Utility Doors


Exterior personnel door assemblies other than at main entrances.
100 See B20
200 See B2050
300 Doors and door frames defined by type, hardware; narrative
associated with specific model elements; envelope and space
requirements are represented in model element.
Specific doors, frames and hardware. Hardware set functionality and
types are specified.
350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening is modeled
Major framing elements are modeled at jambs and head
400 Modeled units will meet the minimum requirements of LOD 350, in
addition to the following:
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2050.30 – Exterior Oversize Doors


Large exterior door assemblies to allow for passage of large objects involving various operating methods.
100 See B20
200 See B2050
300 Doors and door frames defined by type, hardware; narrative
associated with specific model elements; envelope and space
requirements are represented in model element.
Specific doors, frames and hardware. Hardware set functionality and
types are specified.
Clearance zones are modeled for operation of overhead doors
Enclosures and motor housings are modeled with overall
nominal dimensions
350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening is modeled (if applicable)
Major framing elements are modeled at jambs and head
400 Modeled units will meet the minimum requirements of LOD 350, in
addition to the following:

B2050.40 – Exterior Special Function Doors


[See B2050.20 Exterior Utility Doors]

B2050.60 – Exterior Grilles


Exterior devices of open construction to provide moveable barrier to provide access through wall or other
divider.
100 See B20
200 See B2050
300 See B2050
350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening is modeled (if applicable)
Major framing elements are modeled at jambs and head
400 Modeled units will meet the minimum requirements of LOD 350, in
addition to the following:

B2050.70 – Exterior Gates


Exterior devices of solid or open construction to provide moveable barrier to provide access through wall or
other divider.
[See B2050.60 Exterior Grilles]

B2050.90 – Exterior Door Supplementary Components


Includes frames, hardware, glazing and louvers that are part of door to be included with exterior door elements
above as appropriate.

34
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2070 - Exterior Louvers and Vents


100 Represented as a calculated value, usually derived as a percentage of
exterior vertical surface area; or, as a ratio to overall habitable space.
200 Generic model element that is indicative of approximate area and
location of intended louver/vent.

B2070.10 – Exterior Louvers


100 See B20
200 See B2070
300 Specific model element, indicative of specific area and location of
intended louver/vent.
Includes specific frame (boundary dimensions) and blades.
Opening for louver is cut from host wall

350 Modeled units will meet the minimum requirements of LOD 300, in
addition to the following:
Rough opening is modeled (if applicable)
Major framing elements are modeled at jambs and head
400 Modeled units will meet the minimum requirements of LOD 350, in
addition to the following:

B2070.50 – Exterior Vents


[See B2070.10 Exterior Louvers]

B2080 - Exterior Wall Appurtenances


B2080.10 – Exterior Fixed Grilles and Screens
Exterior enclosures, grilles and screens of wood, metal, plastic, and other materials for a variety of purposes
including screening of equipment.

B2080.30 – Exterior Opening Protection Devices


Manufactured items such as louvers, fins, shutters, demountable panels, awnings, and sun screens to provide
sun control, privacy, security, insulation, and storm protection on exterior of windows, skylights, and entrances.
Includes fixed and moveable, manually and electrically operated, and automatically controlled devices.

B2080.50 – Exterior Balcony Walls and Railings


Manufactured items such as louvers, fins, shutters, demountable panels, awnings, and sun screens to provide
sun control, privacy, security, insulation, and storm protection on exterior of windows, skylights, and entrances.
Includes fixed and moveable, manually and electrically operated, and automatically controlled devices.

B2080.70 – Exterior Fabrications


[See general LOD definitions.]

B2080.80 – Bird Control Devices


[See general LOD definitions.]
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B2090 – Exterior Wall Specialties


Complete fabrication of metal, wood, and fiberglass, including accessories and appurtenances. For example,
clocks, below-grade egress assemblies, and window wells.
See general LOD definitions.

B30 – Exterior Horizontal Enclosures


100 Narrative, information attached to other model elements.

B3010 – Roofing
100 Narrative, information attached to other model elements.
200 Generic assembly that may contain spatial (layer) allowance for
structural slab/deck and/or framing system.

300 Individual substrate layers may not be separately modeled, but


they are specified and their extents are shown precisely.
Roof structure is modeled separately.

B3010.10 – Steep Slope Roofing


Lapped roofing shingles, shakes and roofing tiles, including fastening and flashing products and methods.
[See B1020 - Roof Construction. Steep slope roofing material is often modeled as a layer within the overall roof
structure assembly.]

B3010.50 – Low Slope Roofing


Includes membrane roofing of various types and protected membrane roofing, including fastening and flashing
products.
100 See B30
200 See B3010
300 Specific material thickness, openings are subtracted from solid.
Framing is a separate assembly, see SUPERSTRUCTURE.
Drainage pitches are modeled.
350
400

B3010.70 – Canopy Roofing

36
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B3010.90 – Roofing Supplementary Components


Includes substrate boards, vapor retarder, air barriers, deck insulation, flashing and sheet metal, and
expansion joints to be included with roofing elements above as appropriate.
100 See B30
200 See B3010
300
350
400

B3020 – Roof Appurtenances


100 See B30
200 Not modeled
300

B3020.10 – Roof Accessories


Includes ladders, curbs, vents, walkways, and snow guards.
[See also: B1080.80 - Ladders]
100 See B30
200 Not modeled
300 Ladders: Specific assemblies indicating length, width and
connection method.
350
400

B3020.30 – Roof Specialties


Includes cupolas, spires, steeples, and weathervanes.
See general LOD definitions.

B3020.70 – Rainwater Management


Includes conductor heads, gutters, downspouts, scuppers, and splash blocks.
100 See B30
200 Generic assemblies.
[See also D2030.20 Stormwater Drainage Equipment]
300 Mfr. Specific drains, all connected drainage (?). Locations
specific.
350
400
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B3040 – Traffic Bearing Horizontal Enclosures


100 See B30
200 Not modeled.
300

B3040.10 –Traffic Bearing Coatings


Includes surface applied waterproofing exposed to weather and suitable for pedestrian or vehicular traffic.
[Not Modeled]

B3040.30 – Horizontal Waterproofing Membrane


Includes substrate board, deck insulation, vapor retarder, sheet metal flashing and trim, flexible flashing, and
expansion joints.
100 See B30
200 Not modeled
300 Specific material thickness, manufacturer, finish, color
350
400

B3040.50 – Wear Surfaces


Wearing surfaces on top of horizontal waterproofing membrane that are suitable for pedestrian or vehicular
traffic.
100 Not modeled
200 Not modeled
300 Specific material thickness, manufacturer, finish, color
350
400 Placement of pedestals?

B3040.90 – Horizontal Enclosure Supplementary Components


Includes substrate board, deck insulation, vapor retarder, sheet metal flashing and trim, flexible flashing, and
expansion joints to be included with horizontal enclosure elements above as appropriate.
[Supplementary components may be modeled with other assemblies as listed in the tables above.]

B3060 – Horizontal Openings


100 Not modeled.
200 Not modeled.

38
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

B3060.10 – Roof Windows and Skylights


Wearing surfaces on top of horizontal waterproofing membrane that are suitable for pedestrian or vehicular
traffic.
100 Not modeled.
200 Not modeled.
300 Specific material thickness, manufacturer, finish, color.
350
400 Placement of pedestals?

B3060.50 – Vents and Hatches


Other roof openings such as roof hatches, smoke vents, and gravity roof ventilators.

B3060.90 – Horizontal Opening Supplementary Components


Includes: Frames, hardware, glazing, flashing, and joint sealants to be included with horizontal opening
elements above as appropriate.
[Supplementary components may be modeled with other assemblies as listed in the tables above.]

B3080 – Overhead Exterior Enclosures


B3080.10 – Exterior Ceilings
100 Not modeled.
150 Not modeled
200 Generic assemblies
300 Specific assemblies in specific locations

B3080.20 – Exterior Soffits


100 Not modeled.
150 Not modeled
200 Generic assemblies
300 Specific assemblies in specific locations

B3080.30 – Exterior Bulkheads


100 Not modeled.
150 Not modeled
200 Generic assemblies
300 Specific assemblies in specific locations
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C – INTERIORS
C10 – Interior Construction
100 Interior construction model elements can be placed as a
generic representation with their default parameters, used as
placeholders for assurance of program, code, zoning
compliance and visualization of the conceptual design.
200 Interior construction model elements are graphically
represented as generic systems, objects or assemblies with
approximate location and orientation, including height. Non-
graphic data may be attached to elements.
300 Interior construction model elements are graphically
represented as specific systems, objects or assemblies with
specific location and orientation. Non-graphic data should be
fully populated, including specific type, life safety, finish and
similar parameters.
350 Interior construction model elements are graphically
represented with additional detail not normally shown in the
design intent documentation necessary for cross trade
interference check.
400 Interior construction model elements are graphically
represented as detailed elements, and may include
manufacturer specific non-graphic data.
500 Interior construction model elements are graphically
represented as detailed elements actual in the as built
condition and should include all pertinent manufacturer specific
non-graphic data.

C1010 – Interior Partitions


100 Generic representation or massing of core elements (shafts,
corridors, separation walls, etc.) necessary for assurance of
program, code, zoning compliance and visualization of the
conceptual design.
200 Generic objects with approximate location, orientation and
height necessary for other system definitions, including all
required parametric data.
300 Specific and accurate assemblies with all hardware and
accessories tagged and scheduled. Non-graphical data should
be fully populated for each separate assembly, including all
required parametric data.
350 Inclusion of any accessory backing and structural bracing that
may affect/conflict with other scopes of work.
400 Fabrication details including blocking/backing and any
necessary structural supports, actual manufacturer's details,
identity and parametric data.
500 Installation details that reflect actual as built conditions and
corresponding manufacturer’s identity and parametric data.

40
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1010.10 – Interior Fixed Partitions


100 Shafts, corridors & separation walls for intended use.
200 Graphical representation with required parametric data.
300 Specific partition types with accurate assemblies, dimensions,
locations and heights, containing all required tagging,
scheduling and parametric data.
350 Detailed blocking, kickers, cross bracing, etc.
400 All assembly components including studs, tracks, bracing,
insulation, sheathing and openings ready for fabrication.
Include specific identity and related parametric data
500 See C1010

C1010.20 – Interior Glazed Partitions


100 Not modeled, info attached to other elements, if required.
200 See C1010.10
300 See C1010.10
350 See C1010.10
400 See C1010.10
500 See C1010

C1010.40 – Interior Demountable Partitions


100 See C1010
200 See C1010
300 See C1010.10
350 See C1010.10
400 All assembly components specific to manufacturer's product.
Include all identity and related parametric data
500 See C1010

C1010.50 – Interior Operable Partitions


100 See C1010.20
200 See C1010.10
300 Specific partition types with accurate dimensions, locations and
heights, containing all required hardware and accessories,
support structure, tagging, scheduling and parametric data and
any necessary connection points to other scopes of work.
350 Detailed blocking, kickers, cross bracing, detailed overhead
supports and mechanical connections.
400 All assembly components including tracks, panels, hardware
and supports ready for fabrication. Include specific identity and
related parametric data
500 See C1010
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1010.70 – Interior Screens


100 See C1010.20
200 See C1010.10
300 Graphical representation with required parametric data.
350 See C1010
400 Graphical representation with specific identity and parametric
data.
500 See C1010

C1010.90 – Interior Partitions Supplementary Components


100 See C1010.20
200 See C1010.10
300 See C1010.70
350 See C1010
400 See C1010.70
500 See C1010

C1020 – Interior Windows


100 See C1010
200 Generic windows with approximate size, location and
orientation.
300 Specific and accurate assemblies with all hardware and
accessories tagged and scheduled. Non-graphical data should
be fully populated for each separate assembly, including all
required parametric data.
350 Inclusion of any accessory backing and structural bracing that
may affect/conflict with other scopes of work.

400 Fabrication details including blocking/backing and any


necessary structural supports, actual manufacturer's details,
profiles, hardware, identity and parametric data.
500 Installation details that reflect actual as built conditions and
corresponding manufacturer's identity and parametric data.

42
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1020.10 – Interior Operating Windows


100 Not modeled, info attached to other elements, if required.
200 Graphical representation with required parametric data.
300 Specific window types with specific dimensions, locations &
heights, properly tagged & scheduled.
350 Supplemental rigid bracing
400 All assembly components including profiles, hardware, glazing,
attachments and supports ready for fab.
500 See C1020

C1020.20 – Interior Fixed Windows


100 See C1020.10
200 See C1020.10
300 See C1020.10
350 See C1020.10
400 See C1020.10
500 See C1020

C1020.50 – Interior Special Function Windows


100 See C1020.10
200 See C1020.10
300 See C1020.10
350 See C1020.10
400 See C1020.10
500 See C1020

C1020.90 – Interior Window Supplementary Components


100 See C1020.10
200 See C1020.10
300 See C1020.10
350 See C1020.10
400 See C1020.10
500 See C1020
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1030 – Interior Doors


100 See C1010
200 Generic doors with approximate size, location and orientation
and required parametric data.
300 Specific and accurate assemblies with all hardware and
accessories tagged and scheduled, and inclusion of any
necessary connection points to other scopes of work. Include
all required parametric data for each separate assembly.
350 See C1010
400 Fabrication details including blocking/backing, king-stud
placement, structural supports and actual manufacturer details,
profiles, hardware, identity and parametric data
500 Installation details that reflect actual as built conditions and
corresponding manufacturer's identity and parametric data.

C1030.10 – Interior Swinging Doors


100 Corridors & separation walls for intended use.
200 Graphical representation with required parametric data.
300 Specific door types with specific dimensions, locations &
heights, properly tagged & scheduled.
350 Supplemental rigid bracing
400 All assembly components including profiles, hardware,
attachments and supports ready for fabrication.
500 See C1030

C1030.20 – Interior Entrance Doors


100 Not modeled, info attached to other elements, if required.
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.10
500 See C1030

C1030.25 – Interior Sliding Doors


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.10
500 See C1030

44
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1030.30 – Interior Folding Doors


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.25
500 See C1030

C1030.40 – Interior Coiling Doors


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.25
500 See C1030

C1030.50 – Interior Panel Doors


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.10
500 See C1030

C1030.70 – Interior Special Function Doors


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.10
500 See C1030

C1030.80 – Interior Access Doors and Panels


100 See C1030.20
200 See C1030.10
300 See C1030.10
350 See C1030.10
400 See C1030.10
500 See C1030
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1030.90 – Interior Door Supplementary Components


100 See C1030.20
200 See C1030.10
300 See C1030.10
400 Graphical representation with specific identity and parametric
data.
500 See C1030

C1040 – Interior Grilles and Gates


100 May be graphically represented or verbally described.
200 Generic objects with approximate size and placement, and
required parametric data.
300 Specific and accurate assemblies with all hardware and
accessories tagged and scheduled, and inclusion of any
necessary connection points to other scopes of work. Include
all required parametric data for each separate assembly.
350 Inclusion of any accessory backing and structural bracing that
may affect/conflict with other scopes of work.
400 Fabrication details including blocking/backing, structural
supports and actual manufacturer details, profiles, hardware,
identity and parametric data.
500 Installation details that reflect actual as built conditions and
corresponding manufacturer's identity and parametric data.

C1040.10 – Interior Grilles and Gates


100 Not modeled, info attached to other elements, if required.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.
400 See C1030.10
500 See C1040

C1040.50 – Interior Gates


100 See C1040.10
200 See C1040.10
300 See C1040.10
350 See C1040.10
400 See C1030.10
500 See C1040

46
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1060 – Raised Floor Construction


100 See C1040
200 Generic objects with approximate size and placement, and
required parametric data.
300 Specific and accurate assemblies, including grid spacing, with
all hardware and accessories tagged and scheduled. Include all
required parametric data for each separate assembly.
350 See C1010
400 Fabrication details including blocking/backing, structural
supports and actual manufacturer details, profiles, hardware,
identity and parametric data.
500 Installation details that reflect actual as built conditions and
corresponding manufacturer's identity and parametric data.

C1060.10 – Access Flooring


100 Not modeled, info attached to other elements, if required
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.
350 Accurate floor grid layout and pedestal placement
400 All assembly components including frame, floor tiles, pedestals
and cross bracing ready for fabrication.
500 See C1060

C1060.30 – Platform/Stage Floors


100 See C1060.10
200 See C1060.10
300 See C1060.10
350 Accurate sub-structure assemblies.
400 All assembly components including fixed construction of raised
floors ready for fabrication.
500 See C1060

C1070 – Suspended Ceiling Construction


100 See C1040
200 See C1040
300 See C1060
350 See C1010
400 See C1020
500 See C1010
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1070.10 – Acoustical Suspended Ceilings


100 Not modeled, info attached to other elements, if required.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.
350 Extruded grid placement and any accessory back-up
components.
400 All assembly components including tees, hangers and tiles
ready for fabrication.
500 See C1070

C1070.20 – Suspended Plaster and Gypsum Board Ceilings


100 See C1070.10
200 See C1070.10
300 See C1070.10
350 Incorporation of all accessory back-up components.
400 All assembly components including furring chanels, hangers,
lath, plaster coats and gypsum boards ready for fabrication.
500 See C1070

C1070.50 – Specialty Suspended Ceilings


100 See C1070.10
200 See C1070.10
300 See C1070.10
350 See C1070.20
400 All assembly components including framing, hangers and tiles
ready for fabrication.
500 See C1070

C1070.70 – Special Function Suspended Ceilings


100 See C1070.10
200 See C1070.10
300 See C1070.10
350 See C1070.20
400 See C1070.50
500 See C1070

48
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1070.90 – Ceiling Suspension Components


100 See C1070.10
200 See C1070.10
300 See C1070.10
350 See C1070.20
400 Graphical representation with specific identity and parametric
data.
500 See C1070

C1090 – Interior Specialties


100 See C1040
200 See C1040
300 See C1060
350 See C1010
400 Fabrication details including blocking/backing, structural
supports and actual manufacturer details, profiles, hardware,
identity and parametric data.
500 Installation details that reflect actual as built conditions and
corresponding manufacturer's identity and parametric data.

C1090.10 – Interior Railings and Handrails


100 Not modeled, info attached to other elements, if required.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.
350 Backing & imbedded inserts.
400 All assembly components including rails, pickets, infill panels,
fasteners and supports ready for fabrication.
500 See C1090

C1090.15 – Interior Louvers


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 Supplemental rigid bracing.
400 See C1090.10
500 See C1090
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1090.20 – Information Specialties


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.25 – Compartments and Cubicles


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.30 – Service Walls


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.35 – Wall and Door Protection


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

50
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1090.40 – Toilet, Bath and Laundry Accessories


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.45 – Interior Gas Lighting


100 See C1090.10
200 See C1090.10
300 Specific types with specific dimensions, locations, properly
tagged & scheduled, including any necessary connection points
to other scopes of work.
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.50 – Fireplaces and Stoves


100 See C1090.10
200 See C1090.10
300 See C1090.45
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.60 – Safety Specialties


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C1090.70 – Storage Specialties


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C1090.90 – Other Interior Specialties


100 See C1090.10
200 See C1090.10
300 See C1090.10
350 See C1090.10
400 See C1090.10
500 See C1090

C20 – Interior Finishes


100 Not represented in the model, unless necessary to establish
visualization of the conceptual design, and does not satisfy the
requirements for LOD 200.
200 Interior finish model elements may be graphically represented
as generic materials or as non-graphic data attached to Interior
construction elements where needed to support other systems.
300 Interior finish model elements are graphically represented as
specific systems, objects or assemblies with specific location,
orientation and thickness. Non-graphic data should be fully
populated, and may be attached to other Interior Construction
elements
350 Interior construction model elements are graphically
represented with additional detail and information not normally
shown in the design intent documentation necessary for cross
trade interference check.
400 Interior finish model elements are graphically represented as
detailed assemblies or non-graphic data attached to other
Interior construction elements
500 Interior finish model elements are graphically represented as
detailed as built assemblies and should include all pertinent
manufacturer specific non-graphic data.

52
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2010 – Wall Finishes


100 No info.
200 Generic materials, approximate dimensions, thickness and
elevations.
300 Finishes may not be actually modeled, but they are specified
and their extents are shown precisely.
350 Finishes are actually modeled for visual cross trade
coordination.
400 Detailed assemblies or materials that may be attached to other
interior construction elements.
500 Detailed as built assemblies and specific corresponding
manufacturer's non graphic data.

C2010.10 –Tile Wall Finish


100 No info.
200 Graphical representation with required parametric data or info
attached to other elements properly scheduled.
300 Objects modeled to depict thickness (may be attached to other
objects/assemblies) where it may affect other scopes of work.

C2010.20 – Wall Paneling


100 No info.
200 See C2010.10
300 See C2010.10

C2010.30 – Wall Coverings


100 No info.
200 See C2010.10
300 See C2010.10

C2010.35 – Wall Carpeting


100 No info.
200 See C2010.10
300 See C2010.10

C2010.50 – Stone Facing


100 No info.
200 See C2010.10
300 See C2010.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2010.60 – Special Wall Surfacing


100 No info.
200 See C2010.10
300 See C2010.10

C2010.70 – Wall Painting and Coating


100 No info.
200 See C2010.10
300 See C2010.10

C2010.80 – Acoustical Wall Treatment


100 No info.
200 See C2010.10
300 See C2010.10

C2010.90 – Wall Finish Supplementary Components


100 No info.
200 See C2010.10
300 See C2010.10

C2020 – Interior Fabrications


100 No info.
200 See C2010
300 See C2010
400 See C2010
500 See C2010

C2030 – Flooring
100 No info.
200 Finishes may be generically modeled with approximate
dimensions, or attached to other model elements.
300 Modeled with specific thickness and grid layout where finishes
affect details. All finishes are specified and their extents are
shown precisely.
350 Finishes are actually modeled for visual cross trade
coordination.
400 See C2010
500 See C2010

54
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2030.10 – Flooring Treatment


100 No info.
200 Graphical representation with required parametric data or info
attached to other elements properly scheduled.
300 Objects modeled to depict thickness (may be attached to other
objects/assemblies) where it may affect other scopes of work.

C2030.20 – Tile Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.30 – Specialty Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.40 – Masonry Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.45 – Wood Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.50 – Resilient Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.60 – Terrazzo Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.70 – Fluid-Applied Flooring


100 No info.
200 See C2030.10
300 See C2030.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2030.75 – Carpeting
100 No info.
200 See C2030.10
300 See C2030.10

C2030.80 – Athletic Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.85 – Entrance Flooring


100 No info.
200 See C2030.10
300 See C2030.10

C2030.90 – Flooring Supplementary Components


100 No info.
200 See C2030.10
300 See C2030.10

C2040 – Stair Finishes


100 No info.
200 See C2030
300 Modeled specifically where finishes affect details. All finishes
are specified and their extents are shown precisely.
400 See C2010
500 See C2010

C2040.20 – Tile Stair Finish


100 No info.
200 Graphical representation with required parametric data or info
attached to other elements properly scheduled.
300 Objects modeled to depict thickness (may be attached to other
objects/assemblies) where it may affect other scopes of work.

C2040.40 – Masonry Stair Finish


100 No info.
200 See C2040.20
300 See C2040.20

56
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2040.45 – Wood Stair Finish


100 No info.
200 See C2040.20
300 See C2040.20

C2040.50 – Resilient Stair Finish


100 No info.
200 See C2040.20
300 See C2040.20

C2040.60 –Terrazzo Stair Finish


100 No info.
200 See C2040.20
300 See C2040.20

C2040.75 – Carpeted Stair Finish


100 No info.
200 See C2040.20
300 See C2040.20

C2050 – Ceiling Finishes


100 No info.
200 See C2030
300 See C2040
350 See C2010
400 See C2010
500 See C2010

C2050.10 – Plaster and Gypsum Board Finish


100 No info.
200 Graphical representation with required parametric data or info
attached to other elements properly scheduled.

C2050.20 – Ceiling Paneling


100 No info.
200 See C2050.10

C2050.70 – Ceiling Painting and Coating


100 No info.
200 See C2050.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

C2050.80 – Acoustical Ceiling Treatment


100 No info.
200 See C2050.10

C2050.90 – Ceiling Finish Supplementary Components


100 No info.
200 See C2050.10

C2090 – Interior Finish Schedules


100 No info.
200 See C2010
300 Specific materials. Precise heights, locations of ceiling
devices.
400 Detailed non-graphic data attached to other interior
construction elements.
500 Detailed as built conditions and specific corresponding
manufacturer's non graphic data.

58
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D – SERVICES
D10 – Conveying
100
200 Generic representations of the envelope of the system in terms
of size and location.
300 Specific representations of the envelope of the system in terms
of size and location.
400 Actual representations of the envelope of the system in terms
of size and location plus connection points.

D1010 – Vertical Conveying Systems


100 Narrative, info attached to other elements or quantitative call
outs.
200 Approximate size/shape/location (1).
300 Specific models, precise size, shape & location.
400 Any necessary fabrication details.
500 Detailed as built conditions and specific corresponding
manufacturer's non graphic data.

D1010.10 – Elevators
100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.

D1010.20 – Lifts
100 See D1010.10
200 See D1010.10
300 See D1010.10

D1010.30 – Escalators
100 See D1010.10
200 See D1010.10
300 See D1010.10

D1010.50 – Dumbwaiters
100 See D1010.10
200 See D1010.10
300 See D1010.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D1010.60 – Moving Ramps


100 See D1010.10
200 See D1010.10
300 See D1010.10

D1030 – Horizontal Conveying


100 See D1010
200 See D1010
300 See D1010
400 See D1010
500 See D1010

D1030.10 – Moving Walks


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.

D1030.30 – Turntables
100 See D1030.10
200 See D1030.10
300 See D1030.10

D1030.50 – Passenger Loading Bridges


100 See D1030.10
200 See D1030.10
300 See D1030.10

D1030.70 – People Movers


100 See D1030.10
200 See D1030.10
300 See D1030.10

D1050 – Material Handling


100 See D1010
200 See D1010
300 See D1010
400 See D1010
500 See D1010

60
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D1050.10 – Cranes
100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.

D1050.20 – Hoists
100 See D1050.10
200 See D1050.10
300 See D1050.10

D1050.30 – Derrecks
100 See D1050.10
200 See D1050.10
300 See D1050.10

D1050.40 – Conveyors
100 See D1050.10
200 See D1050.10
300 See D1050.10

D1050.50 – Baggage Handling Equipment


100 See D1050.10
200 See D1050.10
300 See D1050.10

D1050.60 – Chutes
100 See D1050.10
200 See D1050.10
300 See D1050.10

D1050.70 – Pneumatic Tube Systems


100 See D1050.10
200 See D1050.10
300 See D1050.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D1080 – Operable Access Systems


100 See D1010
200 See D1010
300 See D1010
400 See D1010
500 See D1010

D1080.10 – Suspended Scaffolding


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly
tagged & scheduled.

D1080.20 – Robe Climbers


100 See D1080.10
200 See D1080.10
300 See D1080.10

D1080.30 – Elevating Platforms


100 See D1080.10
200 See D1080.10
300 See D1080.10

D1080.40 – Powered Scaffolding


100 See D1080.10
200 See D1080.10
300 See D1080.10

D1080.50 – Building Envelope Access


100 See D1080.10
200 See D1080.10
300 See D1080.10

62
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D20 – Plumbing
100 Generic elements or quantitative call outs;
conceptual and/or schematic layout/flow diagram;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
element(s);
design performance Information;
approximate access/code clearance requirements represented
in the model
shaft requirements represented in the model

D2010 – Domestic Water Distribution


D2010.10 – Facility Potable-Water Storage Tanks
100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
tank(s);
design performance Information;
approximate access/code clearance requirements represented
in the model
300 Specific elements;
modeled as design specified size/shape/spacing/location of
tank(s);
approximate allowances for spacing and clearances required
for all specified anchors, supports, vibration and seismic control
that are utilized in the layout of tanks(s);
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual
size/shape/spacing/location/connections of tank(s)
actual size/shape/spacing/clearances required for all specified
anchors, supports, vibration and seismic control that are
utilized in the layout of tanks(s);
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2010.20 – Domestic Water Equipment


100 See D2010.10
200 Generic elements;
schematic layout with approximate size/shape/location of
equipment;
design performance Information;
approximate access/code clearance requirements represented
in the model
300 Specific elements;
modeled as design specified size/shape/spacing/location of
equipment;
approximate allowances for spacing and clearances required
for all specified anchors, supports, vibration and seismic control
that are utilized in the layout of equipment;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all specified
anchors, supports, vibration and seismic control that are
utilized in the layout of equipment;
400 See D2010.10

64
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2010.40 – Domestic Water Piping


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location
of mains and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
pipe/valves/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances
required for all specified hangers, supports, vibration
and seismic control that are to be utilized in the layout
of all risers/mains/branches;
actual access/code clearance requirements represented
in the model

350 Detailed elements;


modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
pipe/valves/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all
hangers, supports, vibration and seismic control that are
utilized in the layout of all risers/mains/branches;
actual floor and wall penetrations required represented
in the model

400 See D2010.10


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2010.60 – Plumbing Fixtures


100 See D2010.10
200 Generic elements;
schematic layout with approximate size/shape/location
of fixtures;
design performance Information;
carrier and wall width requirements represented in the
model
300 Specific elements;
modeled as design specified
size/shape/spacing/location of fixtures;
approximate allowances for spacing and clearances
required for all specified supports that are to be utilized
in the layout of all fixtures;
actual access/code clearance requirements represented
in the model

350 Detailed elements;


modeled as contractor submitted actual
size/shape/spacing/location/connections of
fixtures/carriers
actual size/shape/spacing/clearances required for all
supports that are utilized in the layout of all fixtures;

400 See D2010.10

66
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2010.90 – Domestic Water Distribution Supplementary Components


100 See D2010.40
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D2010.10

D2020 – Sanitary Drainage


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2020.10 – Sanitary Sewerage Equipment


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.

200 Generic elements;


schematic layout with approximate size/shape/location
of equipment;
design performance Information;
approximate access/code clearance requirements
represented in the model

300 Specific elements;


modeled as design specified
size/shape/spacing/location of equipment;
approximate allowances for spacing and clearances
required for all specified anchors, supports, vibration
and seismic control that are utilized in the layout of
equipment;
actual access/code clearance requirements represented
in the model

68
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

350 Detailed elements;


modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all
specified anchors, supports, vibration and seismic
control that are utilized in the layout of equipment;

400 Manufacturer or Contractor elements added to the


model required for fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2020.30 – Sanitary Sewerage Piping


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location/slope of
pipe/valves/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances
required for all specified hangers, supports, vibration
and seismic control that are to be utilized in the layout
of all risers/mains/branches;
actual access/code clearance requirements represented
in the model

300 Detailed elements;


modeled as contractor submitted actual elements
actual size/shape/spacing/location/slope of
pipe/valves/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all
hangers, supports, vibration and seismic control that are
utilized in the layout of all risers/mains/branches;
actual floor and wall penetrations required represented
in the model

350 Detailed elements;


modeled as contractor submitted actual
size/shape/spacing/location/connections of
risers/mains/branches/valves;
actual insulation/floor and wall penetrations represented
in the model

400 See D2020.10

70
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2020.90 – Sanitary Drainage Supplementary Components


100 See D2020.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D2020.10

D2030 – Building Support Plumbing Systems


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2030.10 – Stormwater Drainage Equipment


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
equipment;
design performance Information;
approximate access/code clearance requirements represented
in the model
300 Specific elements;
modeled as design specified size/shape/spacing/location of
equipment;
approximate allowances for spacing and clearances required
for all specified anchors, supports, vibration and seismic control
that are utilized in the layout of equipment;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all specified
anchors, supports, vibration and seismic control that are
utilized in the layout of equipment;
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation

72
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2030.20 – Stormwater Drainage Piping


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of mains
and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location/slope of
pipe/valves/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all risers/mains/branches;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections/slope of
pipe/valves/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all risers/mains/branches;
actual floor and wall penetrations required represented in the
model
400 See D2030.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2030.30 – Facility Stormwater Drains


100 See D2030.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all components
400 See D2030.10

D2030.60 – Gray Water Systems


100 See D2030.20
200 See D2030.20
300 See D2030.20
350 See D2030.20
400 See D2030.20

74
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2030.90 – Building Support Plumbing System Supplementary Components


100 See D2030.10
200 See D2030.30
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D2030.20

D2050 – General Service Compressed-Air


See D2060.10 – Compressed-Air Systems
D2060 – Process Support Plumbing Systems
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2060.10 – Compressed-Air Systems


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
mains and risers;
design performance Information;
shaft requirements represented in the model

300 Specific elements;


modeled as design specified elements
specified size/shape/spacing/location/slope of
equipment/pipe/valves/fittings/insulation for
risers/mains/branches;
approximate allowances for spacing and clearances
required for all specified hangers, supports, vibration and
seismic control that are to be utilized in the layout of all
risers/mains/branches;
actual access/code clearance requirements represented
in the model

350 Detailed elements;


modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections/slope of
equipment/pipe/valves/fittings/insulation for
risers/mains/branches;
actual size/shape/spacing/clearances required for all
hangers, supports, vibration and seismic control that are
utilized in the layout of all risers/mains/branches;
actual floor and wall penetrations required represented
in the model

400 Manufacturer or Contractor elements added to the model


required for fabrication and field installation

76
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2060.20 – Vacuum Systems


100 See D2060.10
200 See D2060.10
300 See D2060.10
350 See D2060.10
400 See D2060.10

D2060.30 – Gas Systems


100 See D2060.10
200 See D2060.10
300 See D2060.10
350 See D2060.10
400 See D2060.10

D2060.40 – Chemical-Waste Systems


100 See D2060.10
200 See D2060.10
300 See D2060.10
350 See D2060.10
400 See D2060.10

D2060.50 – Processed Water Systems


100 See D2060.10
200 See D2060.10
300 See D2060.10
350 See D2060.10
400 See D2060.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D2060.90 – Process Support Plumbing System Supplementary Components


100 See D2060.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D2060.10

D30 – HVAC
100 Generic elements or quantitative call outs;
conceptual and/or schematic layout/flow diagram;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
element(s);
design performance Information;
approximate access/code clearance requirements represented
in the model
shaft requirements represented in the model

D3010 – Facility Fuel Systems

78
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3010.10 – Fuel Piping


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of mains
and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
pipe/valves/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all risers/mains/branches;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
pipe/valves/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all risers/mains/branches;
actual floor and wall penetrations required represented in the
model
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3010.30 – Fuel Pumps


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
equipment;
design performance Information;
approximate access/code clearance requirements represented
in the model
300 Specific elements;
modeled as design specified size/shape/spacing/location of
equipment;
approximate allowances for spacing and clearances required
for all specified anchors, supports, vibration and seismic control
that are utilized in the layout of equipment;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all specified
anchors, supports, vibration and seismic control that are
utilized in the layout of equipment;
400 See D3010.10

80
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3010.50 – Fuel Storage Tanks


100 See D3010.30

200 Generic elements;


schematic layout with approximate size/shape/location
of tank(s);
design performance Information;
approximate access/code clearance requirements
represented in the model

300 Specific elements;


modeled as design specified
size/shape/spacing/location of tank(s);
approximate allowances for spacing and clearances
required for all specified anchors, supports, vibration
and seismic control that are utilized in the layout of
tanks(s);
actual access/code clearance requirements represented
in the model
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

350 Detailed elements;


modeled as contractor submitted actual
size/shape/spacing/location/connections of tank(s)
actual size/shape/spacing/clearances required for all
specified anchors, supports, vibration and seismic
control that are utilized in the layout of tanks(s);

400 See D3010.10

D3020 – Heating Systems

82
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3020.10 – Heat Generation


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.

200 Generic elements;


schematic layout with approximate size/shape/location
of equipment;
design performance Information;
approximate access/code clearance requirements
represented in the model

300 Specific elements;


modeled as design specified
size/shape/spacing/location of equipment;
approximate allowances for spacing and clearances
required for all specified anchors, supports, vibration
and seismic control that are utilized in the layout of
equipment;
actual access/code clearance requirements represented
in the model
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

350 Detailed elements;


modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all
specified anchors, supports, vibration and seismic
control that are utilized in the layout of equipment;

400 Manufacturer or Contractor elements added to the


model required for fabrication and field installation

D3020.30 – Thermal Heat Storage


100 See D3020.10
200 See D3020.10
300 See D3020.10
350 See D3020.10
400 See D3020.10

D3020.70 – Decentralized Heating Equipment


100 See D3020.10
200 See D3020.10
300 See D3020.10
350 See D3020.10
400 See D3020.10

84
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3020.90 – Heating System Supplementary Components


100 See D3020.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D3020.10

D3030 – Cooling Systems


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3030.10 – Central Cooling


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
equipment;
design performance Information;
approximate access/code clearance requirements represented
in the model
300 Specific elements;
modeled as design specified size/shape/spacing/location of
equipment;
approximate allowances for spacing and clearances required
for all specified anchors, supports, vibration and seismic control
that are utilized in the layout of equipment;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual
size/shape/spacing/location/connections of equipment,
actual size/shape/spacing/clearances required for all specified
anchors, supports, vibration and seismic control that are
utilized in the layout of equipment;
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation

86
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3030.30 – Evaporative Air-Cooling


100 See D3030.10

200 See D3030.10

300 See D3030.10


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

350 See D3030.10

400 See D3030.10

88
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3030.50 – Thermal Cooling Storage


100 See D3030.10
200 See D3030.10
300 See D3030.10
350 See D3030.10
400 See D3030.10

D3030.70 – Decentralized Cooling


100 See D3030.10
200 See D3030.10
300 See D3030.10
350 See D3030.10
400 See D3030.10

D3030.90 – Cooling System Supplementary Components


100 See D3030.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D3030.10

D3050 – Facility HVAC Distribution Systems


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3050.10 – Facility Hydronic Distribution


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location
of mains and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
pipe/valves/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances
required for all specified hangers, supports, vibration
and seismic control that are to be utilized in the layout
of all risers/mains/branches;
actual access/code clearance requirements represented
in the model

350 Detailed elements;


modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
pipe/valves/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all
hangers, supports, vibration and seismic control that are
utilized in the layout of all risers/mains/branches;
actual floor and wall penetrations required represented
in the model

400 Manufacturer or Contractor elements added to the


model required for fabrication and field installation

90
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3050.30 – Facility Steam Distribution


100 See D3050.10
200 See D3050.10
300 See D3050.10
350 See D3050.10
400 See D3050.10

D3050.50 – HVAC Air Distribution


100 See D3050.10
200 See D3050.10
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
duct/dampers/fittings/insulation for risers/mains/branches;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all risers/mains/branches;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
duct/dampers/fittings/insulation for risers/mains/branches;
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all risers/mains/branches;
actual floor and wall penetrations required represented in the
model
400 See D3050.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3050.90 – Facility Distribution Systems Supplementary Components


100 See D3050.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D3050.10

D3060 – Ventilation

92
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3060.10 – Supply Air


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location
of mains and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
duct/dampers/fittings/insulation for
risers/mains/branches;
approximate specified allowances for spacing and
clearances required for all hangers, supports, vibration
and seismic control that are to be utilized in the layout
of all risers/mains/branches;
actual access/code clearance requirements represented
in the model

350 Detailed elements;


modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
duct/dampers/fittings/insulation for
risers/mains/branches;
actual size/shape/spacing/clearances required for all
hangers, supports, vibration and seismic control that are
utilized in the layout of all risers/mains/branches;
actual floor and wall penetrations required represented
in the model

400 Manufacturer or Contractor elements added to the


model required for fabrication and field installation.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3060.20 – Return Air


100 See D3060.10
200 See D3060.10
300 See D3060.10
350 See D3060.10
400 See D3060.10

D3060.30 – Exhaust Air


100 See D3060.10
200 See D3060.10
300 See D3060.10
350 See D3060.10
400 See D3060.10

D3060.40 – Outside Air


100 See D3060.10
200 See D3060.10
300 See D3060.10
350 See D3060.10
400 See D3060.10

D3060.60 – Air-to-Air Energy Recovery


100 See D3060.10
200 See D3060.10
300 See D3060.10
350 See D3060.10
400 See D3060.10

D3060.70 – HVAC Air Cleaning


100 See D3060.10
200 See D3060.10
300 See D3060.10
350 See D3060.10
400 See D3060.10

94
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3060.90 – Ventilation Supplementary Components


100 See D3060.1100
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D3060.10

D3070 – Special Purpose HVAC Systems


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D3070.10 – Snow Melting


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation.

D40 – Fire Protection


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout/flow diagram;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
element(s);
design performance Information;
approximate access/code clearance requirements represented
in the model
shaft requirements represented in the model

D4010 – Fire Suppression

96
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D4010.10 – Water-Based Fire-Suppression


100 Generic elements or quantitative call outs;
conceptual and/or schematic flow diagrams;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of mains
and risers;
design performance Information;
shaft requirements represented in the model
300 Specific elements;
modeled as design specified elements
specified size/shape/spacing/location of
pipe/valves/fittings/insulation for
risers/mains/branches/standpipes;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all
risers/mains/branches/standpipes;
actual access/code clearance requirements represented in the
model
350 Detailed elements;
modeled as contractor submitted actual elements
actual size/shape/spacing/location/connections of
pipe/valves/fittings/insulation for
risers/mains/branches/standpipes;
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all risers/mains/branches/standpipes;
actual floor and wall penetrations required represented in the
model
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation

D4010.50 – Fire-Extinguishing
100 See D4010.10
200 See D4010.10
300 See D4010.10
350 See D4010.10
400 See D4010.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D4010.90 – Fire Suppression Supplementary Components


100 See D4010.10
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
supplementary components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all supplementary
components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of supplementary
components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all supplementary components
400 See D4010.10

D4030 – Fire Protection Specialties

98
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D4030.10 – Fire Protection Cabinets


100 Generic elements or quantitative call outs;
conceptual and/or schematic layout;
minimal design performance information.
200 Generic elements;
schematic layout with approximate size/shape/location of
components;
design performance Information where applicable
300 Specific elements and assemblies;
modeled as design specified size/shape/spacing/location of
components;
approximate allowances for spacing and clearances required
for all specified hangers, supports, vibration and seismic control
that are to be utilized in the layout of all components;
actual access/code clearance requirements represented in the
model
350 Detailed elements and assemblies;
modeled as contractor submitted actual
size/shape/spacing/location/connections of components
actual size/shape/spacing/clearances required for all hangers,
supports, vibration and seismic control that are utilized in the
layout of all components
400 Manufacturer or Contractor elements added to the model
required for fabrication and field installation

D4030.30 – Fire Extinguishers


100 See D4030.10
200 See D4030.10
300 See D4030.10
350 See D4030.10
400 See D4030.10

D4030.50 – Breathing Air Replenishment Systems


100 See D4030.10
200 See D4030.10
300 See D4030.10
350 See D4030.10
400 See D4030.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D4030.70 – Fire Extinguisher Accessories


100 See D4030.10
200 See D4030.10
300 See D4030.10
350 See D4030.10
400 See D4030.10

D50 – Electrical
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model

100
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5010.10 – Packaged Generator Assemblies


Description: Generator, frequency changers, and rotary converters and uninterruptible power units.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment and
associated components
- Approximate allowances for spacing and clearances required
for all specified supports and seismic control that are utilized
- Actual access/code clearance requirements represented in
the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and seismic
control that are utilized
-Actual size/shape/location/connections of equipment and
support structure/pads
400 Contractor elements added to the model required for fabrication
and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5010.20 – Battery Equipment


Description: Batteries, battery racks, battery chargers, static power converters, uninterruptible power supplies,
and accessories. To include Uninterruptable Power Supplies, and Lighting Inverters.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified supports and seismic control
that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
400 Contractor elements added to the model required for
fabrication and field installation

102
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5010.30 – Photovoltaic Collectors


Description: Solar cells to convert sunlight to electricity.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified supports and seismic control
that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
400 Contractor elements added to the model required for
fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5010.40 – Fuel Cells


Description: Fuel cell electricity generating equipment.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified supports and seismic control
that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
400 Contractor elements added to the model required for
fabrication and field installation

104
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5010.70 – Transfer Switches


Description: Switches that transfer from one source of electricity to another.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified supports and seismic control
that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
400 Contractor elements added to the model required for
fabrication and field installation

D5020 – Electrical Service and Distribution


Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5020.10 – Electrical Service Entrance


Description: Meters, substations, transformers, switchgear, switchboards, and protective devices where
electrical power enters structure.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified supports and seismic control
that are utilized
- Actual access/code clearance requirements
represented in the model

350 Detailed elements:


- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of equipment and
associated components
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads

106
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

400 Contractor elements added to the model required for


fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5020.30 – Power Distribution


Description: Bus assemblies, distribution equipment, and electrical wiring system to distribute electrical power
to switchboards, panelboards, and motor control centers.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model

350 Detailed elements:


- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
-Actual floor and wall penetrations required are
represented in the model

108
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

400 Contractor elements added to the model required for


fabrication and field installation

D5020.70 – Facility Grounding


Description: Raceways, wiring and devices for grounding and bonding an electrical distribution system.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures and the electrical equipment and
end-devices served
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures and the electrical equipment and
end-devices served
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual floor and wall penetrations required are
represented in the model
400 Contractor elements added to the model required for
fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5030 – General Purpose Electrical Power


D5030.10 – Branch Wiring System
Description: Raceways, ducts, cable trays, and wiring to deliver power from branch panelboards to the point of
use.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes and enclosures in the branch wiring system
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model

350 Detailed elements:


- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures in the branch wiring system
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual floor and wall penetrations required are
represented in the model

400 Contractor elements added to the model required for


fabrication and field installation

110
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5030.50 – Wiring Devices


Description: Electrical devices at point of use including electrical outlets and switches.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of outlet boxes
and devices.
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of outlet boxes
and devices

400 Contractor elements added to the model required for


fabrication and field installation

D5040 – Lighting
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5040.10 – Lighting Control


Description: Clock and calendar, photoelectric switches, occupancy sensors, and light-leveling control devices.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of enclosures ,
equipment and devices
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of enclosures,
equipment, and control devices
-Actual size/shape/location/connections of equipment
and control devices
400 Contractor elements added to the model required for
fabrication and field installation

112
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5040.20 – Branch Wiring for Lighting


Description: Raceways, ducts, trays, and wiring beyond branch circuit panelboards to lighting fixtures.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures to fixture locations
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures to fixture locations
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual floor and wall penetrations required are
represented in the model
400 Contractor elements added to the model required for
fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5040.50 – Lighting Fixtures


Description: Luminaires, lighting equipment, ballasts, and accessories. Includes fluorescent, high intensity
discharge, incandescent, mercury vapor, neon, and sodium vapor lighting.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of lighting
fixtures
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model

350 Detailed elements:


- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of lighting fixtures.
- Actual size/shape/spacing/location for supports and
seismic control that are utilized

400 Contractor elements added to the model required for


fabrication and field installation

D5080 – Miscellaneous Electrical Systems

114
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5080.10 – Lightning Protection


Description: Wiring and equipment for lightning protection.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures and the electrical equipment, and
end-devices served
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures and the electrical equipment, fixtures
and end-devices served
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
-Actual floor and wall penetrations required are
represented in the model
400 Contractor elements added to the model required for
fabrication and field installation
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D5080.70 – Transient Voltage Suppression


Description: Devices to protect against voltage surges on electrical distribution systems.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of the
equipment
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of the equipment
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
400 Contractor elements added to the model required for
fabrication and field installation

116
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

D60 – Communications
D6010 – Data Communications
D6020 – Voice Communications
D6030 – Audio-Video Communication
D6060 – Distributed Communications and Monitoring
D6090 – Communications Supplementary Components
D70 – Electronic Safety and Security
D7010 – Access Control and Intrusion Detection
D7030 – Electronic Surveillance
D7050 – Detection and Alarm
D7070 – Electronic Monitoring and Control
D7090 – Electronic Safety and Security Supplementary Components
D80 – Integrated Automation
D8010 – Integrated Automation Facility Controls
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E – EQUIPMENT & FURNISHINGS


E10 – Equipment
E1010 – Vehicle and Pedestrian Equipment
100 See D1010
200 See D1010

E1010.10 – Vehicle Servicing Equipment


100 Info or call outs.
200 Graphical representation with required parametric data
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.

E1010.30 – Interior Parking Control Equipment


100 See E1010.10
200 See E1010.10
300 See E1010.10

E1010.50 – Loading Dock Equipment


100 See E1010.10
200 See E1010.10
300 See E1010.10

E1010.70 – Interior Pedestrian Control Equipment


100 See E1010.10
200 See E1010.10
300 See E1010.10

E1030 – Commercial Equipment


100 See D1010
200 See D1010
400 Detailed non-graphic data attached to other interior construction
elements.
500 Detailed as built conditions and specific corresponding
manufacturer's non graphic data.

118
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E1030.10 – Mercantile and Service Equipment


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.

E1030.20 – Vault Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.25 – Teller and Service Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.30 – Refrigerated Display Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.35 – Commercial Laundry and Dry Cleaning Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.40 – Maintenance Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.50 – Hospitality Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.55 – Unit Kitchens


100 See E1030.10
200 See E1030.10
300 See E1030.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E1030.60 – Photographic Processing Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.70 – Postal, Packaging and Shipping Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.75 – Office Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1030.80 – Foodservice Equipment


100 See E1030.10
200 See E1030.10
300 See E1030.10

E1040 – Institutional Equipment


100 See D1010
200 See D1010

E1040.10 – Educational and Scientific Equipment


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.

E1040.20 – Healthcare Equipment


100 See E1040.10
200 See E1040.10
300 See E1040.10

E1040.40 – Religious Equipment


100 See E1040.10
200 See E1040.10
300 See E1040.10

120
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E1040.60 – Security Equipment


100 See E1040.10
200 See E1040.10
300 See E1040.10

E1040.70 – Detention Equipment


100 See E1040.10
200 See E1040.10
300 See E1040.10

E1060 – Residential Equipment


100 See D1010
200 See D1010

E1060.10 – Residential Appliances


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.

E1060.50 – Residential Stairs


100 See E1060.10
200 See E1060.10
300 See E1060.10

E1060.70 – Residential Ceiling Fans


100 See E1060.10
200 See E1060.10
300 See E1060.10

E1070 – Entertainment and Recreational Equipment


100 See D1010
200 See D1010
300 See D1010

E1070.10 – Theater and Stage Equipment


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E1070.20 – Musical Equipment


100 See E1070.10
200 See E1070.10
300 See E1070.10

E1070.50 – Athletic Equipment


100 See E1070.10.
200 See E1070.10
300 See E1070.10

E1070.60 – Recreational Equipment


100 See E1070.10
200 See E1070.10
300 See E1070.10

E1090 – Other Equipment


100 See D1010
200 See D1010

E1090.10 – Solid Waste Handling Equipment


100 Info or call outs.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled

E1090.30 – Agricultural Equipment


100 See E1090.10
200 See E1090.10
300 See E1090.10

E1090.40 – Horticultural Equipment


100 See E1090.10
200 See E1090.10
300 See E1090.10

E1090.60 – Decontamination Equipment


100 See E1090.10
200 See E1090.10
300 See E1090.10

122
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E20 – Furnishings
E2010 – Fixed Furnishings
100 Not Modeled.
200 See D1010
300 See D1010
400 See D1010
500 See D1010

E2010.10 – Fixed Art


100 Not Modeled.
200 Graphical representation with required parametric data.
300 Specific types with specific dimensions, locations, properly tagged
& scheduled.

E2010.20 – Window Treatments


100 See E2010.10
200 See E2010.10
300 See E2010.10

E2010.30 – Casework
100 See E2010.10
200 See E2010.10
300 See E2010.10

E2010.70 – Fixed Multiple Seating


100 See E2010.10
200 See E2010.10
300 See E2010.10

E2010.90 – Other Fixed Furnishings


100 See E2010.10
200 See E2010.10
300 See E2010.10
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

E2050 – Movable Furnishings


E2050.10 – Movable Art
E2050.30 – Furniture
E2050.40 – Accessories
E2050.60 – Movable Multiple Seating
E2050.90 – Other Movable Furnishings

124
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

F – SPECIAL CONSTRUCTION & DEMOLITION

F10 – Special Construction


F1010 – Integrated Construction
F1020 – Special Structures
F1030 – Special Function Construction
F1050 – Special Facility Components
F1060 – Athletic and Recreational Special Construction
F1080 – Special Instrumentation
F20 – Facility Remediation
F2010 – Hazardous Materials Remediation
F30 – Demolition
F3010 – Structure Demolition
F3030 – Selective Demolition
F3050 – Structure Moving
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G – BUILDING SITEWORK
G10 – Site Preparation
100 A written civil, site, and landscape architecture narrative is provided
without site elements modeled. This narrative may reference an
architectural mass model that shows generic building and site scale
and proportion of the project. It may also reference a topographic
surface that is available.

200 Generic element modeling to include:


Approximate size/shape of foundation element
Approximate size/location of utilities and structures
Approximate code and clearance requirements
Approximate pipe material
Rough modeling of site grading
Local structural building grids defined in model and
coordinated with global state plane coordinate system for
site model.

G1010 – Site Clearing


G1020 – Site Elements Demolition
G1030 – Site Element Relocations
G1050 – Site Remediation
G1070 – Site Earthwork

126
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G20 – Site Improvements


100 A written civil, site, and landscape architecture narrative is provided
without site elements modeled. This narrative may reference an
architectural mass model that shows generic building and site scale
and proportion of the project. It may also reference a topographic
surface that is available.

200 Generic element modeling to include:


Approximate size/shape of foundation element
Approximate size/location of utilities and structures
Approximate code and clearance requirements
Approximate pipe material
Rough modeling of site grading
Local structural building grids defined in model and
coordinated with global state plane coordinate system for
site model.

G2010 – Roadways
G2020 – Parking Lots
G2030 – Pedestrian Plazas and Walkways
G2040 – Airfields
G2050 – Athletic, Recreational, and Playfield Areas
G2060 – Site Development
G2080 – Landscaping
G30 – Liquid and Gas Site Utilities
G3010 – Water Utilities
G3020 – Sanitary Sewerage Utilities
G3030 – Storm Drainage Utilities
G3050 – Site Energy Distribution
G3060 – Site Fuel Distribution
G3090 – Liquid and Gas Site Utilities Supplementary Components
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G40 – Electrical Site Improvements


100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model

128
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G4010 – Site Electric Distribution Systems


Description: Electrical wiring systems to distribute electrical power to on the Site. Includes Duct Banks,
Pullboxes, vaults and transformers from the utility point of connection, to the building’s main electric room.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Specified size/shape/spacing/location of equipment
and associated components
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements
represented in the model

350 Detailed elements:


- Manufacturer or contractor submitted actual
elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment
and support structure/pads
-Actual floor and wall penetrations required are
represented in the model
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

400 Contractor elements added to the model required for


fabrication and field installation

G4050 – Site Lighting


Description: Luminaires, lighting equipment, ballasts, and accessories. Includes fluorescent, high intensity
discharge, incandescent, mercury vapor, neon, and sodium vapor lighting. Includes Pole Mount, Building
Mount and on-grade fixtures for exterior lighting.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of lighting fixtures
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized. Includes required pole bases and
footing elements.
- Actual access/code clearance requirements represented in
the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of lighting fixtures.
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment and
support structure/pads
400 Contractor elements added to the model required for
fabrication and field installation

130
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

G50 – Site Communications


100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model

G5010 – Site Communications Systems


Description: Conduit Systems for routing of Communication trunk systems.
100 Generic elements or quantitative call outs:
-Conceptual and/or schematic layout
-Minimal design performance information
200 Generic elements schematic layout with:
- Approximate size/shape/location of equipment
- Design performance Information
- Approximate access/code clearance requirements
represented in the model
300 Specific elements;
modeled as design specified elements:
- Specified size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Specified size/shape/spacing/location of equipment and
associated components
- Approximate allowances for spacing and clearances
required for all specified hangers, supports and seismic
control that are utilized
- Actual access/code clearance requirements represented in
the model
350 Detailed elements:
- Manufacturer or contractor submitted actual elements:
- Actual size/shape/spacing/location of raceways/
boxes/enclosures in the Power Distribution System
- Actual size/shape/spacing/location for supports and
seismic control that are utilized
-Actual size/shape/location/connections of equipment and
support structure/pads
-Actual floor and wall penetrations required are represented
in the model
400 Contractor elements added to the model required for
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

fabrication and field installation

G90 – Miscellaneous Site Construction


G9010 – Tunnels

132
Level of Detail Specification www.bimforum.org/lod
Version: DRAFT 2013

APPENDIX