You are on page 1of 2

3DJH  RI 

0RWRU67$786 &DVH 1XPEHU 

&DVH+LVWRU\
This data set was acquired on a 200
hp motor in a paper plant as a
quick demonstration of the
MotorSTATUS unit. The motor
had been in place for 2 weeks,
replacing a motor that had failed
after only 6 months.

Data was acquired over an 80-


minute period. Note the fault
alarms in the load, HFD, and
upper non-synchronous displays.
Data acquisition was set at a “4
hour trend.”

• Load is cycling, and overload is


severe.

• Overload period will


significantly shorten motor life.

• This situation needs further


investigation.

• This information indicates a


bad bearing.

• The last trend point was


acquired after 7 shots of
grease.

• HFD confirmed using 2120


Greased bearing Machinery Analyzer.

$XWKRU Bruce Hoge 'DWH December 15, 1997


&RPSDQ\ MJ Electric 3ODQW Plant (anonymity requested)
3DJH  RI 
0RWRU67$786 &DVH 1XPEHU 

&DVH+LVWRU\
Upper, non-synchronous increases
with load. Alarms in this parameter
usually indicate a bearing problem.

Suspect large high frequency peak


is caused by bearing defect.
Confirmation of bearing defect
frequency is needed.

Bearing frequency?

&RQFOXVLRQV5HFRPPHQGDWLRQV
• Previous motor failed the inboard bearing in 6 months.
• Severe overload exists.
• New motor showing early signs of a bearing problems.
• Process needs to be changed or motor resized.

$XWKRU Bruce Hoge 'DWH December 15, 1997


&RPSDQ\ MJ Electric 3ODQW Paper Plant (anonymity requested)