You are on page 1of 2

0RWRU67$786

3DJHRI
&DVH1XPEHU$

&DVH+LVWRU\
• Data taken from a 900 hp,
3585rpm booster feed pump.

• Non-redundant pump.

• Plant will lose 350mw if this


pump goes down.

• Machine averages 91% load,


but peaks most days up to
110% to 120%.

• Motor averages 13% time


above 100% load.

• Motor has 1.2 service factor.

1x mechanical vibration is steadily


climbing and has doubled in the last
4 months. This indicates a balance
or bearing problem.

$XWKRUSean McGrady 'DWHDecember 18, 1997


&RPSDQ\CSI 3ODQWPower Plant (anonymity requested)
0RWRU67$786
3DJHRI
&DVH1XPEHU$

&DVH+LVWRU\

The two dominate peaks are 1x


mechanical and 2x electrical line.

1x mechanical

120Hz electrical

The presence of 2x line is unusual


at this amplitude. The fact it is
increasing signals a growing
problem. This parameter usually
indicates rotor eccentricity.

&RQFOXVLRQV 5HFRPPHQGDWLRQV

• As of 12/18/97, motor is operating and problem is being watched.

• A full 2120 Machinery Analyzer work up has been performed. Data indicates lack of axial vibration and phase
orientation indicating that misalignment is unlikely.

• Suspect mechanical imbalance or worn bearings.

$XWKRUSean McGrady 'DWHDecember 18, 1997


&RPSDQ\CSI 3ODQWPower Plant (anonymity requested)