Professional Documents
Culture Documents
Level instruments
Siemens FI 01 · 2008
SITRANS L Level instruments
Product overview
■ Overview
Application Device description Page Programming
Software
Point level measurement - Capacitance switches
Powerful range of level Pointek CLS100/CLS200/CLS300/CLS500
switches suitable for a variety • CLS100: compact 2-wire inverse frequency shift 5/9 –
of industries capacitance switch for level detection in constricted
spaces, interfaces, solids, liquids, slurries and foam
• CLS200: a versatile inverse frequency shift capaci- 5/15 SIMATIC PDM
tance level switch with optional rod/cable choices
and configurable output, ideal for detection of liq-
uids, solids, slurries, foam and interfaces; digital ver-
sion (with PROFIBUS PA) includes a display and
provides additional diagnostic features
• CLS300: inverse frequency shift capacitance level 5/31 SIMATIC PDM
switch with optional rod/cable choices and config-
urable output. It is ideal for detecting liquids, solids,
slurries, foam and interfaces in demanding condi-
tions where high pressure and temperatures are
present; digital version (with PROFIBUS PA) includes
a display and provides additional diagnostic features
5
• CLS500: inverse frequency shift capacitance level 5/47 SIMATIC PDM
switch for detecting interfaces, solids, liquids, toxic
and aggressive chemicals in critical conditions of
high temperature and pressure; HART® communica-
tion for remote commissioning
Point level measurement - Electro-mechanical switches
Reliable rotating and vibrating SITRANS LPS200/LVS200
point level switches for bulk • LPS200: rotating switch that detects high, low and 5/64 –
solids at a competitive price demand conditions for bulk solids
• LVS200: vibrating point level switch with unique ro- 5/72 –
bust tine design, for use on bulk solids
5
level transmitter for continu- • Simple operation using the graphical local user inter-
ous monitoring of liquids and face (LUI)
slurries in storage and pro-
cess vessels including high • Plug-and-play setup using the intuitive Quick Start
temperature and pressure, to Wizard
a range of 20 m (66 ft); ideal • 25 GHz high frequency allows for small horn anten-
for small vessels and low nas and easy mounting in nozzels
dielectric media
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Sup-
pression of fixed obstructions
• Communication using HART® or PROFIBUS PA
4-wire, 6 GHz pulse radar SITRANS LR300 5/171 SIMATIC PDM
level transmitter for continu- • Cost-effective level measurements with powerful ra-
ous monitoring of liquids and dar measuring system for process and tank control in
slurries in storage and pro- extremely difficult processes and atmospheres
cess vessels including high
temperature and pressure, to • Reliable level measurements in liquids and slurries
a range of 20 m (66 ft) up to 20 m (65 ft)
4-wire, 24 GHz FMCW radar SITRANS LR400 5/185 SIMATIC PDM
level transmitter for continu- • Minimum maintenance requirements and wear as re-
ous monitoring of liquids and sult of non-contacting measuring principle
slurries in storage and pro-
cess vessels including high • High long-term stability resulting from self-calibration
temperature and high pres- with highly stable internal reference
sure, to a range of 50 m • High measuring accuracy and repeatability as result
(164 ft); ideal for low dielectric of 24 GHz; narrow beam angle for tall, narrow vessels
media
4-wire, 24 GHz FMCW radar SITRANS LR460 5/192 SIMATIC PDM
level transmitter with • Process Intelligence for advanced signal processing
extremely high signal-to-noise and quick and easy adjustment
ratio and advanced signal
processing for continuous • Self-guided quick start wizard for plug and play start-
monitoring of solids up to up
100 m (328 ft); ideal for mea- • 100 m (328 ft) range for long-range and difficult ap-
surement in extreme dust plications
Continuous measurement - Guided wave radar transmitters
SITRANS LG200 is a guided SITRANS LG200 5/197 –
wave radar transmitter for • Measures accurately on materials with dielectric (dK)
short and medium range as low as 1.4
level, level/interface and vol-
ume measurement of liquids • Guided wave radar measurement for up to 2.5 mm
and solids. It is unaffected by (0.12”) accuracy
changes in process condi- • Measures level and interface on challenging appli-
tions, high temperatures and cations including foam
pressures, and steam
• 3 button programming for quick setup
• Reliable level measurement on harsh applications
with pressure up to 430 bar g (6250 psi g) and tem-
peratures as high as +427 °C (+800 °F)
5
environment (typically the vessel wall) acts as the reference der the influence of an electric field. This is measured by a ratio
electrode, while the probe supplies the measurement electrode. which compares the capacitance of a condenser with the mate-
The dielectric is composed of the vessel contents and, if the rial as dielectric to its capacitance with a vacuum/dry air as di-
measurement electrode is insulated, the insulating layer. electric: the dielectric constant of air is 1.
Active shield
The portion of the probe isolated from the active measurement
section. The sensor signal is connected to the active shield por-
tion of the probe, eliminating the electrical potential difference
between the shield and the measurement section. So, the shield
portion of the probe near the process connection is not affected
by changes in vapour concentration, material buildup, dust or
condensation.
■ Technical specifications
Point Level Measurement Continuous Level/Interface
Measurement
Criteria Pointek CLS100 Pointek CLS200 Pointek CLS300 Pointek CLS500 SITRANS LC300 SITRANS LC500
Typical applications Liquids, slurries, Liquids, slurries, Liquids, slurries, Water in oil level, Conductive or non- Water in oil, foam or
powders, granules, powders, granules, powders, granules, foam or liquid/ foam conductive liquids, liquid/foam level,
applications in con- foam, food and relatively high pres- level, glycol regen- foam or liquid/foam high-pressure coa-
stricted spaces pharmaceuticals, sure and tempera- erators, high-pres- levels, water in oil lescers, LNG (Liqui-
petrochemicals ture, hazardous sure coalescers levels fied Natural Gas)
areas
Max. length includ- 100 mm (4”) Rod: 5.5 m (18 ft) Rod: 1 m (40“) Rod: 1 m (40”) Rod: 5.5 m (18 ft) Rod: 5.5 m (18 ft)
ing sensor Cable: up to 30 m Cable: 25 m (82 ft) Cable: 25 m (82 ft) Cable: 35 m (115 ft)
(98 ft)
Process Tempera- • Stainless steel • -40 to +85 °C • -40 to +200 °C • -50 to +200 °C -20 to +200 °C • -50 to +200 °C
ture (Temperature process connec- (-40 to +185 °F) (-40 to +392 °F) (-58 to +392 °F) (-4 to +392 °F) (-58 to +392 °F)
ratings are pressure tion: • With temp. ext.: • HT version: • HT version: • Option:
dependent. -40 to +100 °C -40 to +125 °C -40 to +400 °C -60 to +400 °C -60 to +400°C
See Pressure/Tem- (-40 to +212 °F) (-40 to +257 °F) (-40 to +752 °F) (-76 to +752 °F) (-76 to +752°F)
perature curves for • PPS process con-
respective prod- nection:
uct.) -20 to +100 °C
(-4 to +212 °F) 5
Process Pressure Up to 10 bar g • Rod and ext. ver- Up to 35 bar g • Up to 150 bar g Up to 35 bar g • Up to 150 bar g
(Pressure ratings (146 psi g) sions: (511 psi g) (2175 psi g) (511 psi g) (2175 psi g)
are temperature Up to 25 bar g • HP version: • Option:
dependent. See (365 psi g) Up to 345 bar g Up to 345 bar g
Pressure/Tempera- • Cable version: (5004 psi g) (5004 psi g)
ture curves for Up to 10 bar g
respective prod- (146 psi g)
uct.)
Output • 4 or 20/20 or 4 mA CLS200 Standard: CLS300 Standard: • 4 to 20/20 to 4 mA 4 to 20/20 to 4 mA • 4 to 20/20 to 4 mA
2-wire current 1 SPDT Form C 1 SPDT Form C 2-wire current 2-wire current loop 2-wire current
loop relay, solid-state relay, solid-state loop loop
• Solid-state output switch switch • Solid-state switch • Solid-state switch
(stainless steel CLS200 Digital: CLS300 Digital:
cable or enclo- solid-state switch solid-state switch
sure version) included included
• Relay output (ful-
ly-synthetic ver-
sion)
Communications • CLS200 Standard: • CLS300 Standard: HART, SIMATIC HART, SIMATIC
3 LED indicators 3 LED indicators PDM compatible PDM compatible
• CLS200 Digital: • CLS300 Digital:
PROFIBUS PA; PROFIBUS PA;
SIMATIC PDM SIMATIC PDM
compatible compatible
Power Specifica- • Standard: • CLS200 Standard: • CLS300 Standard: • 12 to 33 V DC 9 to 32 V DC any • 12 to 33 V DC
tions 12 to 33 V DC 12 to 250 V 12 to 250 V (30 V DC for IS) polarity, 2-wire cur- (30 V DC for IS)
• Intrinsically Safe: AC/DC, 50/60 Hz, AC/DC, 50/60 Hz, at 3.6 mA, 9.5 to rent loop circuit at 3.6 mA, 9.5 to
10 to 30 V DC 2 VA/2 W max. 2 VA/2 W max. 33 V DC, (9 V at 22 mA) 33 V DC (30 V DC)
• CLS200 Digital: • CLS300 Digital: (30 V DC for IS) at at 22 mA
- bus voltage: - bus voltage: 22 mA • 3.6 to 22 mA/
9 to 32 V DC, 9 to 32 V DC, • 3.6 to 22 mA/ 22 to 3.6 mA
IS version 9 to IS version 9 to 22 to 3.6 mA (2-wire current
24 V DC 24 V DC (2-wire current loop)
- current con- - current con- loop)
sumption: sumption:
12.5 mA 12.5 mA
Approvals CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM,
ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK,
Lloyd’s Register, Lloyd’s Register, Lloyd’s Register, Lloyd’s Register Lloyd’s Register Lloyd’s Register
WHG WHG WHG Current Signalling Current Signalling Current Signalling
according to according to according to
NAMUR NE 43 NAMUR NE 43 NAMUR NE 43
■ Overview ■ Configuration
■ Application
Pointek CLS100’s short insertion length of 100 mm (4") and ver-
satility in various applications and in vessels or pipes makes it a Pointek CLS100 installation
good replacement for traditional capacitance sensors.
Its advanced tip-sensing technology provides accurate, repeat-
able switchpoint performance. The PPS (Polyphenylene sulfide)
probe [optional PVDF (Polyvinylidene Fluoride)] is chemically re-
sistant with an effective process operating temperature range
from -40 to +100 °C (-40 to +212 °F) (7ML5501), and -20 to
+100 °C (-4 to +212 °F) (7ML5610). The fully potted design en-
sures reliability in a vibrating environment such as agitated tanks
up to 4 g. When used with a SensGuard protection cover, the
CLS100 is protected from shearing, impact and abrasion in
tough primary processes.
The Pointek CLS100 is available in three versions. The integral
cable version has a stainless steel process connection and
probe options of PPS or PVDF. The fully synthetic version has a
thermoplastic polyester enclosure with a PPS process connec-
tion combined with a PPS probe. The standard enclosure version
has a thermoplastic polyester enclosure with a stainless steel
process connection in combination with a PPS or PVDF probe.
• Key Applications: liquids, slurries, powders, granules, food
and pharmaceuticals, chemicals, hazardous areas
■ Technical specifications
Stainless steel process connection (integral cable Synthetic process connection (fully synthetic
or enclosure version) (7ML5501) enclosure version only) (7ML5610)
Mode of operation
Measuring principle Inverse frequency shift capacitive level detection Inverse frequency shift capacitive level detection
Input
Measured variable Change in picoFarad (pF) Change in picoFarad (pF)
Output
Output signal
• Alarm output 4 or 20/20 or 4 mA 2-wire loop 4 or 20/20 or 4 mA 2-wire loop
• Switch output Solid-state: 30 V DC/30 V AC (peak), max. 82 mA Max. switching voltage: 220 V DC/AC (peak)
Max. switching current: 2 A
Max. switching power: 60 W
Intrinsically Safe 30 V DC Not applicable
• Fail-safe mode Min. or max. Min. or max.
Accuracy
Repeatability 2 mm (0.08") 2 mm (0.08")
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS100, stainless steel process con- 7ML 5 5 0 1 - Pointek CLS100, PPS process connection 7ML 5 6 1 0 -
nection Compact 2-wire inverse frequency shift capaci-
0 7 7 77 0 77 77
Compact 2-wire inverse frequency shift capaci- tance switch for level detection in constricted
tance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and
spaces, interfaces, solids, liquids, slurries and foam
foam
Process connection (PPS)
Process connection ¾” NPT [(Taper), ANSI/ASME B1.20.1] A
¾” NPT [(Taper), ANSI/ASME B1.20.1] A (PPS probe body)
R 1” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E R 1” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B
G 1” [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] J (PPS probe body)
Approvals Approvals
General Purpose A General Purpose A
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, C ATEX II 1D 1/3D T107 °C C
E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 Versions/Options
T107 °C
Enclosure version, PPS process connection, 1
CSA/FM Class II and III, Div. 1, Groups E, F, G G ½” NPT cable inlet
Device version Enclosure version, PPS process connection, 2
Integral cable version (PPS probe) 1 M20x1.5 adapter
Enclosure version (PPS probe), ½” NPT cable inlet 3 WHG approval, German overfill protection
5
Integral version with PVDF probe body 5 Not required 0
Enclosure version with PVDF probe body (½” NPT 6 Required 1
cable inlet) Instruction manual
Enclosure version (PPS probe), M20x1.5 cable inlet 7 Quick start manual, multi-language 7ML1998-5QJ81
(adapter) Note: due to ATEX regulations one Quick start man-
Enclosure version with PVDF probe body, M20x1.5 8 ual is included with every product
cable inlet (adapter) This device is shipped with the Siemens Milltronics
WHG approval, German overfill protection manual CD containing ATEX Quick Starts and
Not required 0 instruction manuals.
Required 1 Accessories
Further designs Order code Sensguard, ¾" NPT (PPS) 7ML1830-1DL
Only available for CLS100 with ¾" NPT thread
Please add "-Z" to Order No. and specify Order Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
code(s). Only available for CLS100 with ¾" NPT thread
FFKM seal O-ring A22 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Inspection Certificate Type 3.1 per EN 10204 C12 text line, suitable for enclosures
■ Options
Note: due to ATEX regulations one Quick start man-
ual is included with every product.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
instruction manuals.
Optional equipment
Sensguard, ¾" NPT (PPS) 7ML1830-1DL
Only available for CLS100 with ¾" NPT thread
Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
Only available for CLS100 with ¾" NPT thread
Tag, Stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
text line, suitable for enclosure
Siemens Intrinsically Safe Barrier (DC powered), 7NG4122-1AA10
ATEX II 1 G EEx ia
½” NPT cable gland, nickel plated brass, fits cable F) 7ML1830-1JA
diameter 6 to 12 mm (0.24 to 0.47”) -40 to +100 °C
(-40 to +212 °F), IP68 (General Purpose)
M20x1.5 cable gland, PA polyamide, ATEX II 2G F) 7ML1830-1JC
EEx e II, fits cable diameter 7 to 12 mm (0.28 to Optional Sensguard dimensions
0.47”), -20 to +70 °C (-4 to +158 °F), IP68
(General Purpose)
F) Subject to export regulations AL: 9I999, ECCN: N.
■ Characteristic curves
■ Dimensional drawings
Integral Cable Version Enclosure Version
80 mm
(3.2”)
power LED (green)
ground post 36 mm nominal* cable inlet ½” NPT
(1.4”) sensitivity trimpot
power LED (green) 1
2
(optional M20x1.5)
cable relief 3
4
65 mm
(2.6”)
NT
ST VITY
5
ME
sensor status
R
AD NSITI
WE
JU
PO
ST NSOR
SE
US
output status
AT
SE
ST TPUT
US
LED (yellow)
AT
OU
OR
NS
sensitivity trimpot
SE
72.5 mm
(2.9”)
50 mm
(2.0”)
process connection
process connection
204 mm
(8.0”)
120 mm
(4.7”) 98 mm 120 mm
(3.9”) 98 mm (4.7”)
nominal (3.9”)
nominal
■ Schematics
■ Overview ■ Configuration
■ Benefits
• Potted construction protects signal circuit from shock, vibra-
tion, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscilla-
tion
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy setup of CLS200 when
you can configure switching threshold, even under the most
demanding process conditions (digital version only)
• Extended rod, cable and sanitary versions available
• Standard version: 3 LED indicators for sensor status, output
status and power
• SIL/IEC61508 compliant for use in safety integrated level ap-
plications for overfill protection (SIL 2)
• Digital version: integral LCD display, and PROFIBUS PA com-
munication
■ Application
Pointek CLS200 installation
The Pointek CLS200 is offered in standard and digital versions.
The standard version has 3 LED indicators with basic relay and
solid-state switch alarms.
The digital version provides an integral LCD display for stand-
alone use, and also provides PROFIBUS PA communication
(profile version 3.0, Class B) for connection to a network.
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 250 V AC/DC for standard version and
12 to 30 V DC for digital version). The stainless steel and PPS
(PVDF optional) materials used in the probe construction pro-
vides a temperature rating up to +125 °C (+257 °F) on the pro-
cess wetted portion of the probe. The switch responds to any
material with a dielectric constant of 1.5 or more by detecting a
change in oscillating frequency, and it can be set to detect be-
fore contact or on contact with the probe.The CLS200 operates
independently of the tank wall or pipe so it does not require an
external reference electrode for level detection in a non-conduc-
tive vessel such as concrete or plastic.
(Note: all specifications listed below apply to Standard and Digital ver- • Pressure (cable version) -1 to 10 bar g/150 psi g (nominal)
sions unless otherwise noted)
• Pressure (optional sliding coupling -1 to 10 bar g/150 psi g (nominal)
Mode of operation version)
Measuring principle Inverse frequency shift capaci- Design
tive level detection
• Material
Input
- Enclosure Epoxy-coated aluminum with gas-
Measured variable Change in picoFarad (pF) ket
Output - Optional thermal isolator 316L stainless steel
Output signal (CLS200 Standard) • Connection Removable terminal block, max.
• Relay output 1 SPDT Form C relay 2.5 mm²
- Max. contact voltage • 30 V DC • Degree of protection IP65/Type 4/NEMA 4 (optional
IP68)
• 250 V AC
• Cable inlet 2 x M20x1.5 thread (option:
- Max. contact current • 5 A (DC) 2 x ½” NPT conduit entry includ-
• 8 A (AC) ing 1 plugged entry), digital ver-
sion has optional PROFIBUS
- Max. switching capacity 150 W (DC) connector
5
- Max. switching capacity 2000 VA (AC) Power supply (CLS200 Standard) 12 to 250 V AC/DC, 0 to 60 Hz
max. 2 W
- Time delay (ON and/or OFF) 1 to 60 s
Power supply (CLS200 Digital)
• Solid-state output
• Bus voltage Standard: 12 to 30 V DC
- Output Galvanically isolated Intrinsically Safe: 12 to 24 V DC
- Protection Against reversed polarity • Current consumption 12.5 mA
(bipolar)
Certificates and approvals
- Max. switching voltage • 30 V (DC) (CLS200 Standard)
• 30 V peak (AC) • General Purpose CE, CSA, FM
- Max. load current 82 mA • Dust Ignition Proof (Intrinsically CSA/FM Class II and III, Div. 1,
- Voltage drop < 1 V, typical at 50 mA Safe probe circuit) Groups E, F, G
- Time delay (pre or post switch- 1 to 60 s ATEX II 1/2 D T100 °C
ing) • Explosion Proof (Intrinsically Safe • CSA/FM Class I, Div. 1,
Output signal (CLS200 Digital) probe circuit) Groups A, B, C, D T4
• ATEX II 1/2 G EExd [ia] IIC T6 to
• Solid-state output (CLS200 Digital) T4
- Output Galvanically isolated • Marine Lloyd’s Register of Shipping, Cat-
- Protection Against reversed polarity egories ENV1, ENV2 and ENV5
(bipolar) • Overfill Protection WHG (Germany)
5
Process R ¾”, 1", 1¼”, 1½” [(BSPT), EN 1½”, 2” sanitary fitting clamp R ¾”, 1", 1¼”, 1½” [(BSPT), EN
Connection 10226/PT (JIS-T), JIS B 0203] 316L stainless steel 10226/PT (JIS-T), JIS B 0203]
¾”, 1", 1¼”, 1½” NPT [(Taper), ¾”, 1", 1¼”, 1½” NPT [(Taper),
ANSI/ASME B1.20.1] ANSI/ASME B1.20.1]
G ¾”, 1", 1½” [(BSPP), EN ISO G ¾”, 1", 1½” [(BSPP),
228-1/PF (JIS-P), JIS B 0202] EN ISO 228-1/PF (JIS-P), JIS B 0202]
316L stainless steel 316L stainless steel
ASME/EN flange ASME/EN flange
Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene (FEP)
optional PFA coated1) cable with stainless steel core
Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF)
O-ring seal material2) FKM FKM FKM
Thermal isolator Optional Optional Optional
Extension User selected length User selected length Cable extension
1)
PFA coating (7ML5505) has 120 micron thickness.
2)
FFKM available as special option. Contact nacc.smpi@siemens.com for details.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, threaded/sanitary version 7ML 5 5 0 2 - Pointek CLS200, threaded/sanitary version 7ML 5 5 0 2 -
Versatile inverse frequency shift capacitance level 77 7 77 - 0 777 Versatile inverse frequency shift capacitance level 777 77 - 0 777
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces slurries, foam and interfaces
Note: To select Standard or Digital CLS200 (with Process connection
PROFIBUS PA), see final place holder under ¾” NPT [(Taper), ANSI/ASME B1.20.1] A
Electronics/output. 1" NPT [(Taper), ANSI/ASME B1.20.1] B
Probe version 1½” NPT [(Taper), ANSI/ASME B1.20.1] C
(Threaded lengths include process thread.) R ¾” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] D
Compact,120 mm (4.72”)1) 0X R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E
Extended rod, 250 mm (9.84”)1) 1A R 1½” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F
Extended rod, 350 mm (13.78”)2) 1B 1¼” NPT [(Taper), ANSI/ASME B1.20.1] K
Extended rod, 500 mm (19.69”)2) 1C G ¾” [(BSPP), EN ISO 228-1/PF (JIS-P), L
Extended rod, 750 mm (29.53”)2) 1D JIS B 0202]
Extended rod, 1000 mm (39.37”)2) 1E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] M
Add order code Y01 and plain text: “Insertion
G 1½” [(BSPP), EN ISO 228-1/PF (JIS-P), N
length ... mm”
JIS B 0202]
- Extended rod, 200 to 999 mm (7.87 to 39.33”)3) 1F
1" sanitary fitting clamp6) and 7) R
- Extended rod, 1001 to 2000 mm 1G
1½” sanitary fitting clamp6) and 7) S
(39.41 to 78.74”)2)
2" sanitary fitting clamp6) and 7) T
5
- Extended rod, 2001 to 3000 mm 1H
(78.78 to 118.11”)2) and 4) 2½” sanitary fitting clamp6) and 7) V
- Extended rod, 3001 to 4000 mm 1J 3" sanitary fitting clamp6) and 7) W
(118.15 to 157.48”)2) and 4) Approvals
- Extended rod, 4001 to 5000 mm 1K General Purpose 1
(157.52 to 196.85”)2) and 4) CSA/FM Class II and III Div. 1, Groups E, F, G8) 2
- Extended rod, 5001 to 5500 mm 1L FM Class I Div. 1, Groups A, B, C, D T48) 3
(196.89 to 216.53”)2) and 4) CSA Class I, Div. 1, Groups A, B, C, D T48) 4
Extended cable, 3000 mm (118.11”), length adjust- 2A ATEX II 1/2 D T 100 °C 8) 5
able by customer1) ATEX II 1/2 G EEx d [ia] IIC T6 to T48) 6
Extended cable, 6000 mm (236.22”), length adjust- 2B CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7
able by customer1) CSA/FM Class II and III, Div. 2, Groups F, G;
Add order code Y01 and plain text: “Insertion ATEX II 3G 2D EEx nA II T6 to T4 T100 °C9)
length ... mm” CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
- Extended cable, 500 to 4999 mm 2C E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
(19.69 to 196.81”)1) T100 °C9) and 10)
- Extended cable, 5000 to 9999 mm 2D CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(196.85 to 393.66”)1) E, F, G T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
- Extended cable, 10000 to 14999 mm 2E T100 °C9)
(393.7 to 590.5”)1) Enclosure (see also option A01)
- Extended cable, 15000 to 19999 mm 2F Aluminum epoxy coated
(590.6 to 787.4”)1) • 2 x ½” NPT via adapter, cable inlet, IP65 0
- Extended cable, 20000 to 24999 mm 2G • 2 x M20x1.5 cable inlet, IP65 1
(787.4 to 894.3”)1) • 2 x ½” NPT via adapter, cable inlet, IP68 2
- Extended cable, 25000 to 29999 mm 2H • 2 x M20x1.5 cable inlet, IP68 3
(984.3 to 1181.1”)1)
Additional options
Sanitary compact, 98 mm (3.8”)1) and 5) 3A Standard version (PPS probe body) A
Add order code Y01 and plain text: “Insertion With thermal isolator (PPS probe body) B
length ... mm” With PVDF probe body C
- Sanitary extended, 110 to 999 mm 3B With thermal isolator and PVDF probe body D
(4.3 to 39.3”)1) and 5) With sliding coupling (PPS probe body) E
- Sanitary extended, 1001 to 2000 mm 3C With thermal isolator and sliding coupling F
(39.4 to 78.7”)1) and 5) With sliding coupling and PVDF probe body G
- Sanitary extended, 2001 to 3000 mm 3D With thermal isolator, sliding coupling and PVDF H
(78.8 to 118.1”)1) 4) and 5) probe body
- Sanitary extended, 3001 to 4000 mm 3E WHG approval, German overfill protection
(118.1 to 157.5”)1) 4) and 5) Not required A
- Sanitary extended, 4001 to 5000 mm 3F Required8) B
(157.5 to 196.9”)1) 4) and 5)
- Sanitary extended, 5001 to 5500 mm 3G Electronics/output
(196.9 to 216.5”)1) 4) and 5) Standard version without display, 0
12 to 230 V AC/DC, solid-state and relay output11)
Digital version with display, 24 V DC, solid-state 1
output and PROFIBUS PA11) and 12)
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange 7ML 5 5 0 4 - Pointek CLS200, welded flange 7ML 5 5 0 4 -
Versatile inverse frequency shift capacitance level 77 7 77 - 77 77 Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces. slurries, foam and interfaces.
Note: To select Standard or Digital CLS200 (with Welded flange, 316L stainless steel, Type A flat
PROFIBUS PA), see final place holder under faced
Electronics/output. DN 25, PN 16 J4
Probe version (length from flange face) DN 25, PN 40 J6
Compact, 98 mm (3.86”) 0X DN 40, PN 16 K4
Extended rod, 250 mm (9.84”) 1A DN 40, PN 40 K6
Extended rod, 350 mm (13.78”) 1B DN 50, PN 16 L4
Extended rod, 500 mm (19.69”) 1C DN 50, PN 40 L6
Extended rod, 750 mm (29.53”) 1D DN 80, PN 16 M4
Extended rod, 1000 mm (39.37”) 1E DN 80, PN 401) M6
Add order code Y01 and plain text: “Insertion DN 100, PN 161) N4
length ... mm” DN 100, PN 401) N6
- Extended rod, 200 to 999 mm (7.87 to 39.33”) 1F (Note: Flange bolting patterns and facings dimen-
- Extended rod, 1001 to 2000 mm 1G sionally correspond to the applicable ASME B16.5,
(39.41 to 78.74”) or EN 1092-1 standard.)
- Extended rod, 2001 to 3000 mm 1H
(78.78 to 118.11”)1) Approvals
General Purpose 1
5
- Extended rod, 3001 to 4000 mm 1J CSA/FM Class II and III Div. 1, Groups E, F, G2) 2
(118.15 to 157.48”)1) FM Class I Div. 1, Groups A, B, C, D T42) 3
- Extended rod, 4001 to 5000 mm 1K
(157.52 to 196.85”)1) CSA Class I, Div. 1, Groups A, B, C, D T42) 4
- Extended rod, 5001 to 5500 mm 1L ATEX II 1/2 D T100 °C2) 5
(196.89 to 216.53”)1) ATEX II 1/2 G EEx d [ia] IIC T6 to T42) 6
Extended cable, 3000 mm (118.1”), length adjust- 2A CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7
able by customer CSA/FM Class II and III, Div 2, Groups F, G; ATEX II
Extended cable, 6000 mm (236.2”), length adjust- 2B 3G 2D EEx nA II T6 to T4 T100 °C3)
able by customer CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8
Add order code Y01 and plain text: “Insertion E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
length ... mm” T100 °C3) and 4)
- Extended cable, 500 to 4999 mm 2C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(19.69 to 196.81”) E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
- Extended cable, 5000 to 9999 mm 2D T100 °C3)
(196.85 to 393.66”) Enclosure (see also option A01)
- Extended cable, 10000 to 14999 mm 2E Aluminum epoxy coated
(393.7 to 590.5”) • 2 x ½” NPT via adapter - cable inlet, IP65 0
- Extended cable, 15000 to 19999 mm 2F • 2 x M20x1.5 cable inlet, IP65 1
(590.6 to 787.4”) • 2 x ½” NPT via adapter - cable inlet, IP68 2
- Extended cable, 20000 to 24999 mm 2G • 2 x M20x1.5 cable inlet, IP68 3
(787.4 to 894.3”)
- Extended cable, 25000 to 29999 mm 2H Additional options
(984.3 to 1181.1”) Standard version (PPS probe body) A
With thermal isolator (PPS probe body) B
Process connection
Welded flange, 316L stainless steel, raised face With PVDF probe body C
1" ASME, 150 lb A1 With thermal isolator and PVDF probe body D
1" ASME, 300 lb A2 WHG approval, German overfill protection
1" ASME, 600 lb A3 Not required A
1½” ASME, 150 lb B1 Required2) B
1½” ASME, 300 lb B2 Electronics/output
1½” ASME, 600 lb B3 Standard version without display, 0
2" ASME, 150 lb C1 12 to 230 V AC/DC, solid-state and relay output5)
2" ASME, 300 lb C2 Digital version with display, 24 V DC, solid-state 1
2" ASME, 600 lb C3 output and PROFIBUS PA5) and 6)
3" ASME, 150 lb D1
3" ASME, 300 lb1) D2
3" ASME, 600 lb1) D3
4" ASME, 150 lb1) E1
4" ASME, 300 lb1) E2
4" ASME, 600 lb1) E3
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange, PFA coated 7ML 5 5 0 5 - Pointek CLS200, welded flange, PFA coated 7ML 5 5 0 5 -
Versatile inverse frequency shift capacitance level 77 7 77 - 77 77 Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces. slurries, foam and interfaces.
Note: To select Standard or Digital CLS200 (with Approvals
PROFIBUS PA), see final place holder under General Purpose 1
Electronics/output. CSA/FM Class II and III Div. 1, Groups E, F, G2) 2
Probe version (length from flange face) FM Class I Div. 1, Groups A, B, C, D T42) 3
Compact, 98 mm (3.86”) 0X CSA Class I, Div. 1, Groups A, B, C, D T42) 4
Extended rod, 250 mm (9.84”) 1A ATEX II 1/2 D T100 °C2) 5
Extended rod, 350 mm (13.78”) 1B ATEX II 1/2 G EEx d [ia] IIC T6 to T42) 6
Extended rod, 500 mm (19.69”) 1C CSA/FM Class I, Div 2, Groups A, B, C, D T4; 7
Extended rod, 750 mm (29.53”) 1D CSA/FM Class II and III, Div 2, Groups F, G; ATEX II
Extended rod, 1000 mm (39.37”) 1E 3G 2D EEx n A IIC T6 to T4 T100 °C3)
Add order code Y01 and plain text: “Insertion CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8
length ... mm” E, F, G T4; ATEX II 1G 1/2D EEx ia IIC T6 to T4
- Extended rod, 200 to 999 mm (7.87 to 39.33”) 1F T100 °C3) and 4)
- Extended rod, 1001 to 2000 mm 1G CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(39.41 to 78.74”) E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
T100 °C3)
- Extended rod, 2001 to 3000 mm 1H
(78.78 to 118.11”)1) Enclosure (see also option A01)
5 - Extended rod, 3001 to 4000 mm
(118.15 to 157.48”)1)
1J Aluminum epoxy coated
• 2 x ½” NPT via adapter - cable inlet, IP65 0
- Extended rod, 4001 to 5000 mm 1K • 2 x M20x1.5 cable inlet, IP65 1
(157.52 to 196.85”)1) • 2 x ½” NPT via adapter - cable inlet, IP68 2
- Extended rod, 5001 to 5500 mm 1L • 2 x M20x1.5 cable inlet, IP68 3
(196.89 to 216.53”)1)
Additional options
Process connection Standard version (PPS Probe body) A
Welded flange, 316L stainless steel, raised face, With thermal isolator (PPS Probe body) B
PFA coated
With PVDF probe body C
1" ASME, 150 lb A1
With thermal isolator and PVDF probe body D
1" ASME, 300 lb A2
1" ASME, 600 lb A3 WHG approval, German overfill protection
Not required A
1½” ASME, 150 lb B1
Required2) B
1½” ASME, 300 lb B2
1½” ASME, 600 lb B3 Electronics/output
Standard version without display, 12 to 0
2" ASME, 150 lb C1
230 V AC/DC, solid-state and relay output5)
2" ASME, 300 lb C2
Digital version with display, 24 V DC, solid-state 1
2" ASME, 600 lb C3 output and PROFIBUS PA5) and 6)
3" ASME, 150 lb D1 Further designs Order code
3" ASME, 300 lb1) D2
3" ASME, 600 lb1) D3 Total insertion length: enter the total insertion length Y01
in plain text description
4" ASME, 150 lb1) E1 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
4" ASME, 300 lb1) E2 suring-point number/identification (max. 20 charac-
4" ASME, 600 lb1) E3 ters); specify in plain text
Welded flange, 316L stainless steel, Type A flat
faced, PFA coated Electrical connection/cable inlet: PROFIBUS con- A01
DN 25, PN 16 J4 nector M123) 7) and 8)
DN 25, PN 40 J6 Optional enclosure lid: Lid with glass window A04
instead of closed lid without window5)
DN 40, PN 16 K4
Acceptance test certificate: Manufacturer's test C11
DN 40, PN 40 K6
certificate M to DIN 55350, Part 18 and ISO 9000
DN 50, PN 16 L4 Inspection Certificate Type 3.1 per EN 10204 C12
DN 50, PN 40 L6
SIL/IEC61508 Declaration of Conformity [SIL 2 C20
DN 80, PN 16 M4 (overspill)]2)
DN 80, PN 401) M6 Remote Electronics
DN 100, PN 161) N4 • Remote mounted electronics with 2 m (79”) cable A05
DN 100, PN 401) N6 • Remote mounted electronics with 5 m (197”) cable A06
(Note: Flange bolting patterns and facings dimen- • Mounting bracket (including mounting kit) for re- A09
sionally correspond to the applicable ASME B16.5 mote electronics
or EN 1092-1 standard.) Total insertion length: enter the total insertion length Y01
in plain text description
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange, PFA coated 7ML 5 5 0 5 - Instruction manual
Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7 English 7ML1998-5AR02
switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, French 7ML1998-5AR12
slurries, foam and interfaces. German 7ML1998-5AR32
Note: The instruction manual should be ordered as
Instruction manual See page 5/23 a separate line on the order.
Note: The instruction manual should be ordered as
a separate line on the order. Additional instruction manual
Quick Start manual, multi-language 7ML1998-5QE81
This device is shipped with the Siemens Milltronics Note: Due to ATEX regulations, one Quick Start
manual CD containing the complete ATEX Quick manual is included with every product.
Start and instruction manual library.
This device is shipped with the Siemens Milltronics
Accessories See page 5/23
manual CD containing the complete ATEX Quick
1)
Custom shipping methods required. Contact factory for more details. Start and instruction manual library.
2)
Available with electronics option 0 only Accessories
3)
Available with electronics option 1 only Sensguard, ¾" NPT (PPS) 7ML1830-1DL
4)
Barrier required for Intrinsically Safe protection. Only available for CLS200 with ¾" NPT thread
5)
Version with electronics option 0 has a standard closed lid without window Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
as default; version with electronics option 1 has a standard lid with glass Only available for CLS200 with ¾" NPT thread
window as default. ½” NPT cable gland, nickel plated brass, fits cable F) 7ML1830-1JA
6)
An M12 PROFIBUS connector can be selected separately with wildcard diameter 6 to 12 mm (0.24 to 0.47”) -40 to +100 °C
option (A01).
5
(-40 to +212 °F), IP68
7) Available only with enclosure option 1 (General Purpose)
½” NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB
and EEx e II, fits cable diameter 6.5 to 14 mm (0.26
to 0.55”), -60 to +130 °C (-76 to +266 °F), IP68
(Explosion Proof)
M20x1.5 cable gland, PA polyamide, ATEX II 2G F) 7ML1830-1JC
EEx e II, fits cable diameter 7 to 12 mm (0.28 to
0.47”), -20 to +70 °C (-4 to +158 °F), IP68
(General Purpose)
M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD
and EEx e II, fits cable diameter 10.5 to 15.9 mm
(0.41 to 0.63”), under armour cable diameter 6.1 to
11.5 mm (0.24 to 0.45”), -60 to +130 °C (-76 to
+266 °F), IP68 (Explosion Proof)
One metallic cable gland M20x1.5, -40 to +80 °C 7ML1930-1AP
(-40 to +176 °F)
One metallic cable gland M20x1.5, -40 to +80 °C 7ML1930-1AQ
(-40 to +176 °F) with integrated shield connection
(available for PROFIBUS PA)
Blind threaded flanges are available. Please
contact nacc.smpi@siemens.com with a com-
pleted application data sheet on page 5/8.
Spare parts
Test magnet (digital version) 7ML1830-1JE
Amplifier/power supply, standard version C) 7ML1830-1DJ
Amplifier/power supply, digital version 7ML1830-1JF
LCD display (digital version) 7ML1830-1JK
■ Options
■ Characteristic curves
■ Dimensional drawings
■ Schematics
■ Configuration
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Standard version: 3 LED indicators for adjustment control,
output status and power
• Digital version: integral LCD display, and PROFIBUS PA com-
munication
• Push-button calibration, full-function diagnostics
• Multiple output options
• SIL/IEC61508 compliant for use in safety integrated level ap-
plications for overfill protection (SIL 2)
■ Application
The Pointek CLS300 is offered in standard and digital versions.
The standard version has 3 LED indicators with basic relay and
solid-state switch alarms.
The digital version provides an integral LCD display for stand-
alone use, with PROFIBUS PA communication (Profile version
3.0, Class B) when required. Solid-state switch alarm is stan-
dard.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur like
the mining industry.
Pointek CLS300 installation
The fully potted electronics are unaffected by condensation,
dust or vibration.
Wetted parts are made of stainless steel or stainless steel with a
PFA shield for high chemical resistance. Ceramic inserts are
supplied with high temperature CLS300 devices. Materials with
low or high dielectric constants can be accurately detected. The
unique active shield suppresses interference from material
buildup.
The unique modular design of the Pointek CLS300 provides a
wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure require-
ments of specific applications. The modular design makes or-
dering easier and reduces stocking requirements. A wide range
- Max. temperature error 0.2% of actual capacitance value Certificates and approvals (CLS300 Digital)
Installation conditions • Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
Groups E, F, G T4 or T63)
Location Indoor/outdoor • ATEX II 1/2D 2D T100 °C
Ambient conditions • Explosion Proof/Dust Ignition Proof • CSA/FM Class I, II and III, Div. 1,
(Intrinsically Safe probe circuit) Groups A, B, C, D, E, F, G T4
• Ambient temperature -40 to +85 °C (-40 to +185 °F) • ATEX II 1/2GD EEx d [ia] IIC T6
• Pressure range2) -1 to 35 bar g (-14.6 to 511 psi g) to T1 T100 °C
Medium conditions Liquids, bulk solids, slurries and • Intrinsically Safe • CSA/FM Class I, II and III, Div. 1,
interfaces, and applications with Groups A, B, C, D, E, F, G T4 or
viscous materials T63)
• ATEX II 1G 1/2D EEx ia IIC T6 to
• Relative dielectric constant εr Min. 1.5 T4 T100 °C3)
• Temperature range (probe) • Marine Lloyd’s Register of Shipping, Cat-
- Standard version -40 to +200 °C (-40 to +392 °F) egories ENV1, ENV2, and ENV5
Design: Probe
Standard version High Temperature version Cable version
Length Min. 350 mm (14"),
max. 1000 mm (40")
Min. 350 mm (14"),
max. 1000 mm (40")
Min. 1000 mm (40"),
max. 25000 mm (984") 5
Sensor wetted parts PFA (no insulation on active probe), Ceramic (no insulation on active 316 stainless steel, optional PFA
316L stainless steel probe), 316L stainless steel
O-ring seal material1) FKM FKM FKM
Thermal isolator Optional Standard Optional
Extension User selectable length User selectable length User selectable cable length
1)
FFKM available as special option. Contact nacc.smpi@siemens.com for details.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, threaded version 7ML 5 5 1 0 - Pointek CLS300, threaded version 7ML 5 5 1 0 -
Inverse frequency shift capacitance level switch 77 7 77 - 77 A 7 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Approvals
PROFIBUS PA), see final place holder under General Purpose 1
Electronics/output. CSA/FM Class II and III Div. 1, Groups E, F, G T44) 2
Probe version CSA/FM Class I Div. 1, Groups A, B, C, D T44) 3
(Threaded lengths include process thread.) ATEX II 1/2 D T 100 °C 4) 4
Standard version, rod 350 mm (13.78”) 0X ATEX II 1/2 G EEx d [ia] IIC T6 to T14) 5
Extended rod, length 500 mm (19.69”) 1A
CSA/FM Class II and III, Div 1, Groups E, F, G 6
Extended rod, length 750 mm (29.53”) 1B T4 or T6;5)
Extended rod, length 1000 mm (39.37”) 1C ATEX II 1/2D 2D T100 °C6)
Add order code Y01 and plain text: “Insertion CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7
length ... mm” E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
- Extended rod, factory adjusted length 250 to 1D T100 °C5) and 6)
999 mm (9.8 to 39.3”) CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
- Extended cable, length 3000 mm (118.1”), 2A E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T1
length adjustable by customer1) T100 °C6)
5
6)
Available with electronics option 1 only
7)
An M12 PROFIBUS connector can be selected separately with wildcard
option A01.
8)
Available with enclosure option 2 only
9)
Available with approval option 1, 6, and 7 only
10)
Version with electronics option 0 has a standard closed lid without window
as default; version with electronics option 1 has a standard lid with glass
window as default.
11)
See dimension drawings on page 5/44 for further explanation of Y02.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, welded flange 7ML 5 5 0 6 - Pointek CLS300, welded flange 7ML 5 5 0 6 -
Inverse frequency shift capacitance level switch 77 7 77 - 77 77 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 7 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Welded flange, 316L stainless steel, Type A flat
PROFIBUS PA), see final place holder under faced
Electronics/output. DN 25, PN 162) J4
Probe version (length from flange face) DN 25, PN 402) J6
Standard version, rod 350 mm (13.78”) 0X DN 40, PN 16 K4
Extended rod, length 500 mm (19.69”) 1A DN 40, PN 40 K6
Extended rod, length 750 mm (29.53”) 1B DN 50, PN 16 L4
Extended rod, length 1000 mm (39.37”) 1C DN 50, PN 40 L6
Add order code Y01 and plain text: “Insertion DN 80, PN 16 M4
length ... mm” DN 80, PN 403) M6
- Extended rod, length 250 to 999 mm (9.8 to 1D DN 100, PN 163) N4
39.3”) DN 100, PN 403) N6
- Extended cable, length 3000 mm (118.1”), 2A (Note: Flange bolting patterns and facings dimen-
length adjustable by customer sionally correspond to the applicable ASME B16.5
- Extended cable, length 6000 mm (236.2”), 2B or EN 1092-1 standard.)
length adjustable by customer
Approvals
5
Add order code Y01 and plain text: “Insertion General Purpose 1
length ... mm” CSA/FM Class II and III Div. 1, Groups E, F, G T44) 2
- Extended cable, length 1000 to 4999 mm 2C CSA/FM Class I Div. 1, Groups A, B, C, D T44) 3
(39.4 to 196.8”)
- Extended cable, length 5000 to 9999 mm 2D ATEX II 1/2 D T100 °C4) 4
(196.9 to 393.7”) ATEX II 1/2 G EEx d [ia] IIC T6 to T14) 5
- Extended cable, length 10000 to 14999 mm 2E CSA/FM Class II and III, Div 1, Groups E, F, G T4 or 6
(393.7 to 590.5”) T6;5) ATEX II 1/2D 2D T100 °C6)
- Extended cable, length 15000 to 19999 mm 2F CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7
(590.6 to 787.4”) E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
- Extended cable, length 20000 to 25000 mm 2G T100 °C5) and 6)
(787.4 to 984.3”) CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
- Extended PFA cable, length 3000 mm (118.1”), 3A E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T1
length adjustable by customer1) T100 °C6)
- Extended PFA cable, length 6000 mm (236.2”), 3B WHG approval, German overfill protection
length adjustable by customer1) Not required 0
Required 4) 1
Add order code Y01 and plain text: “Insertion
Additional options
length ... mm” Standard version A
- Extended PFA cable, length 1000 to 4999 mm 3C With thermal isolator [for process temperature over B
(39.4 to 196.8”)1) +85 °C (+185 °F)]
- Extended PFA cable, length 5000 to 9999 mm 3D
(196.9 to 393.7”)1) Enclosure (see also option A01)
- Extended PFA cable, length 10000 to 14999 mm 3E Aluminum epoxy coated
(393.7 to 590.5”)1) • 2 x ½” NPT via adapter, cable inlet, IP65 A
• 2 x M20x1.5 cable inlet, IP65 B
- Extended PFA cable, length 15000 to 19999 mm 3F
(590.6 to 787.4”)1) • 2 x ½” NPT via adapter, cable inlet, IP68 C
- Extended PFA cable, length 20000 to 25000 mm 3G • 2 x M20x1.5 cable inlet, IP68 D
(787.4 to 984.3”)1) Electronics/output
Process connection Standard version without display, 0
12 to 250 V AC/DC, solid-state and relay output
Welded flange, 316L stainless steel, raised face Digital version with display, 24 V DC, solid-state 1
1" ASME, 150 lb2) A1 output and PROFIBUS PA7)
1" ASME, 300 lb2) A2
1" ASME, 600 lb2) and 3) A3 Further designs Order code
Please add “-Z” to Order No. and specify Order
1½" ASME, 150 lb B1 code(s).
1½" ASME, 300 lb B2
1½" ASME, 600 lb3) B3 Total insertion length: enter the total insertion length Y01
in plain text description
2" ASME, 150 lb C1 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
2" ASME, 300 lb C2
2" ASME, 600 lb3) C3 suring-point number/identification (max. 20 charac-
ters); specify in plain text
3" ASME, 150 lb D1
3" ASME, 300 lb3) D2 Electrical connection/cable inlet: PROFIBUS con- A01
3" ASME, 600 lb3) D3 nector M126) 8) and 9)
Optional enclosure lid: Lid with glass window A04
4" ASME, 150 lb3) E1 instead of closed lid without window10)
4" ASME, 300 lb3) E2
4" ASME, 600 lb3) E3 Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
SIL/IEC61508 Declaration of Conformity [SIL 2 C20
(overspill)]4)
Extended Active Shield (Y02) (standard length is
105 mm)11)
• Active Shield length (Y02): 230 mm (min. insertion A07
length: rod, 475 mm, cable, 1000 mm)
• Active Shield length (Y02): 380 mm (min. insertion A08
length: rod, 625 mm, cable, 1000 mm)
5
7) An M12 PROFIBUS connector can be selected separately with wildcard
option A01.
8)
Available with enclosure option B only
9)
Available with approval option 1, 6, and 7 only
10)
Version with electronics option 0 has a standard closed lid without window
as default; version with electronics option 1 has a standard lid with glass
window as default.
11)
See dimension drawings on page 5/45 for further explanation of Y02.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, high temperature, threaded 7ML 5 5 0 7 - Pointek CLS300, high temperature, threaded 7ML 5 5 0 7 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Electronics/output
PROFIBUS PA), see final place holder under Standard version without display, 0
Electronics/output. 12 to 250 V AC/DC, solid-state and relay output
Version Digital version with display, 24 V DC, solid-state 1
(Threaded lengths include process thread.) output and PROFIBUS PA4)
Standard version, rod 350 mm (13.78”) 0X Further designs Order code
Extended rod, length 500 mm (19.69”) 1A
Please add “-Z” to Order No. and specify Order
Extended rod, length 750 mm (29.53”) 1B code(s).
Extended rod, length 1000 mm (39.37”) 1C Total insertion length: enter the total insertion length Y01
Extended rod, customer specified length (min. 1D in plain text description
250 mm (9.8”) length, max. 999 mm (39.3”) length) Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Y15
Add order code Y01 and plain text: "Insertion Measuring-point number/identification (max. 20
length ...mm" characters); specify in plain text
Note: Verify that shield length selected in A07 or
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, high temperature, welded 7ML 5 5 0 8 - Pointek CLS300, high temperature, welded 7ML 5 5 0 8 -
flange 77 7 77 - 77 77
flange 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level switch Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with WHG approval, German overfill protection
PROFIBUS PA), see final place holder under Not required 0
Electronics/output. Required 2) 1
Version (length from flange face) Additional options
Standard version, rod 350 mm (13.78”) 0X With thermal isolator [for process temperature over B
Extended rod, length 500 mm (19.69”) 1A +85 °C (+185 °F)]
Extended rod, length 750 mm (29.53”) 1B
Enclosure (see also option A01)
Extended rod, length 1000 mm (39.37”) 1C Aluminum epoxy coated
Extended rod, customer specified length [min. 1D • 2 x ½” NPT via adapter, cable inlet, IP65 A
250 mm (9.8”) length, max. 999 mm (39.3”)length] • 2 x M20x1.5 cable inlet, IP65 B
Add order code Y01 and plain text: "Insertion
length ...mm" • 2 x ½” NPT via adapter, cable inlet, IP68 C
Note: Verify that shield length selected in A07 and • 2 x M20x1.5 cable inlet, IP68 D
A08 is appropriate for the version selected. Electronics/output
Process connection
Welded flange, 316L stainless steel, raised face
Standard version without display,
12 to 250 V AC/DC, solid-state and relay output
Digital version with display, 24 V DC, solid-state
0
1
5
1" ASME, 150 lb A1
output and PROFIBUS PA5)
1" ASME, 300 lb A2
1" ASME, 600 lb1) A3 Further designs Order code
1½" ASME, 150 lb B1 Please add “-Z” to Order No. and specify Order
1½" ASME, 300 lb B2 code(s).
1½" ASME, 600 lb1) B3 Total insertion length: enter the total insertion length Y01
in plain text description
2" ASME, 150 lb C1
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
2" ASME, 300 lb C2
suring-point number/identification (max. 20 charac-
2" ASME, 600 lb1) C3 ters); specify in plain text
3" ASME, 150 lb D1 Electrical connection/cable inlet: PROFIBUS con- A01
3" ASME, 300 lb1) D2 nector M124) 6) and 7)
3" ASME, 600 lb1) D3 Optional enclosure lid: Lid with glass window A04
4" ASME, 150 lb1) E1 instead of closed lid without window8)
4" ASME, 300 lb1) E2 Acceptance test certificate: Manufacturer's test C11
4" ASME, 600 lb1) E3 certificate M to DIN 55350, Part 18 and ISO 9000
Welded flange, 316L stainless steel, Type A flat Inspection Certificate Type 3.1 per EN 10204 C12
faced SIL/IEC61508 Declaration of Conformity [SIL 2 C20
DN 25, PN 16 J4 (overspill)]2)
DN 25, PN 40 J6 Extended Active Shield (Y02) [standard length is
DN 40, PN 16 K4 105 mm (4.13”)]9)
DN 40, PN 40 K6 • Active Shield length (Y02): 230 mm (9.06“) [min. A07
insertion length: rod 475 mm (18.70“), cable
DN 50, PN 16 L4 1000 mm (39.37“)]
DN 50, PN 40 L6 • Active Shield length (Y02): 380 mm (14.96“) [min. A08
DN 80, PN 16 M4 insertion length: rod 625 mm (24.61“), cable
DN 80, PN 401) M6 1000 mm (39.37“)]
DN 100, PN 161) N4 Instruction manual See page 5/40
DN 100, PN 401) N6 Note: The instruction manual should be ordered as
(Note: Flange bolting patterns and facings dimen- a separate line on the order.
sionally correspond to the applicable ASME B16.5
This device is shipped with the Siemens Milltronics
or EN 1092-1 standard.)
manual CD containing the complete ATEX Quick
Approvals Start and instruction manual library.
General Purpose 1 Accessories See page 5/40
CSA/FM Class II and III Div. 1, Groups E, F, G T42) 2
CSA/FM Class I Div. 1, Groups A, B, C, D T42) 3 1)
Custom shipping methods required. Contact factory for more details.
2)
ATEX II 1/2 D T100 °C2) 4 Available with electronics option 0 only
ATEX II ½G EEx d [ia] IIC T6 to T12) 5 3)
Barrier required for Intrinsically Safe protection
CSA/FM Class II and III, Div 1, Groups E, F, G T4 or 6 4)
Available with electronics option 1 only
T6;3) ATEX II 1/2D 2D T100 °C4) 5)
An M12 PROFIBUS connector can be selected separately with wildcard
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7 option (A01).
E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 6)
Available with enclosure option B only
T100 °C3) and 4) 7)
Available with approval option 1, 6, and 7 only
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8 8)
E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T1 Version with electronics option 0 has a standard closed lid without window
T100 °C4) as default; version with electronics option 1 has a standard lid with glass
window as default.
9)
See dimension drawings on page 5/45 for further explanation of Y02.
■ Characteristic curves
■ Dimensional drawings
■ Schematics
■ Overview ■ Configuration
5
Pointek CLS500 is an inverse frequency shift capacitance level
switch for detecting interfaces, solids, liquids, toxic and aggres-
sive chemicals in critical conditions of high temperature and
pressure.
■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
• 2-wire loop powered with solid-state switch or 4 to 20/
20 to 4 mA output
• Simple push-button calibration and integrated local display
• Full function diagnostics
• HART communications for remote commissioning and inspec-
tion
■ Application
Patented Active-Shield technology ensures that measurement is
unaffected by vapours, product deposits, dust and condensa-
tion. The unique mechanical probe design coupled with a high
performance transmitter gives superior performance in a wide
range of level detection applications.
Pointek CLS500’s microprocessor-based electronics provide
Pointek CLS500 installation
one-point calibration, making setup possible without shutting
down your production process.
• Key Applications: foam or liquid/foam level, glycol regenera-
tors, high-pressure coalescers, LNG applications
5
Categories ENV1, ENV2, ENV3,
ENV5
Pressure PED 97/23/EC, CSA B51
Other C-TICK (Australia)
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves
on page 5/53.
2)
Barrier required for Intrinsically Safe protection
Standard Combinations
Pointek CLS500 Standard HT Series
probe version
Process connection Standard (PFA) High Temperature
types (7ML5601, 7ML5602, (Enamel or Stainless
7ML5603) steel) (7ML5604)
Threaded Available as Standard -
Flange Available as Standard Available as Standard
Process connection
materials
316L stainless steel Available as Standard Available as Standard
Probe insulation
None - HT Stainless: Available
as Standard
PFA Available as Standard –
Enamel HT Enamel: Available
as Standard
Length parameters
Max. rod length 1000 mm (40") 1000 mm (40”)
Process
condtitions1)
Max. pressure 150 bar g (2175 psi g) Stainless steel:2)
35 bar g (507 psi g)
Enamel:2)
345 bar g (5004 psi g)
Max. temperature +200 °C (+392 °F) +400 °C (+752 °F)
1) When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves on
page 5/53.
2) Pressure rating of process seal is temperature dependent. See Pres-
sure/Temperature curves on page 5/53.
– Not available as standard
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500, threaded 7ML 5 6 0 1 - Pointek CLS500, welded flange 7ML 5 6 0 2 -
Inverse frequency shift capacitance level switch for 77 7 77 - 77 A 0 Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Electronic transmitter
No transmitter supplied 0 No transmitter supplied 0
MSP 2002-1 (330 pF) 1 MSP 2002-1 (330 pF) 1
Process connection Process connection and pressure rating
¾" A Welded flange, 316L stainless steel, raised face
1" B 2" ASME, 150 lb AA
1¼" C 2" ASME, 300 lb AB
1½" D 3" ASME, 150 lb BA
2" E 3" ASME, 300 lb1) BB
Threaded connection and rating 4" ASME, 150 lb1) CA
NPT [(Taper), ANSI/ASME B1.20.1] A 4" ASME, 300 lb1) CB
R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203] B 6" ASME, 150 lb1) DA
G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] D 6" ASME, 300 lb1) DB
Probe insulation/material of process connection Welded flange, 316L stainless steel, Type A flat
Further designs Order code ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div. 1, Groups A, B, C, D, T4 6
Please add "-Z" to Order No. and specify Order
code(s). Probe/electrode diameter
16 mm (0.63”) rigid rod, min. length 200 mm (7.9”), 1
Insertion length, specify in plain text: Y01 max. length 1000 mm (39.4”)
Y01: ... mm [minimum 200 mm (7.87")]
Active Shield length - minimum length is Y02 Thermal isolator/remote version
50 mm.Y02: ... mm Rigid thermal isolator [for process temperature over A
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15 +85 °C (+185 °F)]
suring-point number/identification (max. 20 charac- No thermal isolator B
ters); specify in plain text
Further designs Order code
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000 Please add "-Z" to Order No. and specify Order
code(s).
Inspection Certificate Type 3.1 per EN 10204 C12
Insertion length, specify in plain text: Y01
Instruction manual See page 5/52 Y01: ... mm [minimum 200 mm (7.87")]
Accessories See page 5/52 Active Shield length - minimum length is Y02
50 mm.Y02: ... mm3)
1) Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
Barrier required for Intrinsically Safe protection
2)
Add order code Y01 and Y02 in plain text: suring-point number/identification (max. 20 charac-
“Insertion/active shield length ... mm” ters); specify in plain text
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Instruction manual See page 5/52
Accessories See page 5/52
1) Custom shipping methods required. Contact factory for more details.
2)
Barrier required for Intrinsically Safe protection
3)
See dimension drawings on page 5/59 for further explanation of Y02.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500, single piece flange 7ML 5 6 0 3 - Pointek CLS500, single piece flange 7ML 5 6 0 3 -
Inverse frequency shift capacitance level switch for 77 7 77 - 77 A 0 Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Further designs Order code
No transmitter supplied 0 Please add "-Z" to Order No. and specify Order
MSP 2002-1 (330 pF) 1 code(s).
Process connection and pressure rating Insertion length, specify in plain text: Y01
Single piece flange, 316L stainless steel, raised Y01: ... mm [minimum 200 mm (7.87")]
face Active Shield length - minimum length is Y02
2" ASME, 150 lb AA 50 mm.Y02: ... mm3)
2" ASME, 300 lb AB Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
suring-point number/identification (max. 20 charac-
3" ASME, 150 lb BA ters); specify in plain text
3" ASME, 300 lb1) BB
Acceptance test certificate: Manufacturer's test C11
4" ASME, 150 lb1) CA certificate M to DIN 55350, Part 18 and ISO 9000
4" ASME, 300 lb1) CB
Inspection Certificate Type 3.1 per EN 10204 C12
6" ASME, 150 lb1) DA
Instruction manual See page 5/52
6" ASME, 300 lb1) DB
Single piece flange, 316L stainless steel, Type B1
raised faced
Accessories
1)
See page 5/52
Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500 High temperature 7ML 5 6 0 4 - Pointek CLS500 High temperature 7ML 5 6 0 4 -
Inverse frequency shift capacitance level switch for 7A 7 77 - 7777 Inverse frequency shift capacitance level switch for 7 A 7 77 - 7777
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Approvals
No transmitter supplied 0 General Purpose A
MSP 2002-1 (330 pF) 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4; B
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
Process connection and pressure rating CSA/FM Class II and III Div. 1, Groups E, F, G;
316L stainless steel, raised face1) CSA/FM Class I, Div. 1, Groups A, B, C, D, T4; C
2" ASME, 150 lb A1 ATEX II 1G EEx ia IIC T6 to T47)
2" ASME, 300 lb A2
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C D
2" ASME, 600 lb A3
FM Class I, Div. 1, Groups A, B, C, D, T4 F
2" ASME, 900 lb A4
3" ASME, 150 lb B1 Probe/electrode diameter
3" ASME, 300 lb2) B2 Maximum length 1000 mm (39.37”)8) A
3" ASME, 600 lb2) B3 Thermal isolator/remote version
3" ASME, 900 lb2) B4 Rigid thermal isolator [for process temperature over 1
4" ASME, 150 lb2) C1 +85 °C (+185 °F)]
■ Characteristic curves
■ Dimensional drawings
■ Schematics
5
Pointek CLS500 connections
Kit, Stainless steel rod 180 mm (7.09”) to be A5E01163719 Spare gasket, CLS500 enclosure version, IP65 A5E01163728
used with CLS300 units only (with standard
active shield). Insertion length after installation is CLS500 Blind Lid
350 mm (13.78”).
Kit, Stainless steel rod 330 mm (12.99”) to be A5E01163720
used with CLS300 units only (with standard
active shield). Insertion length after installation is
500 mm (19.69”).
Kit, Stainless steel rod 580 mm (22.83”) to be A5E01163721 Spare CLS500 aluminum blind lid A5E01163729
used with CLS300 units only (with standard
active shield). Insertion length after installation is Note 1: Special flange sizes and facings are available. Please
750 mm (29.53”). contact nacc.smpi@siemens.com for part number and pricing.
Kit, Stainless steel rod 830 mm (32.68”) to be A5E01163722 Submit Application Questionnaire found on page 5/8.
used with CLS300 units only (with standard
active shield). Insertion length after installation is Note 2: Please contact nacc.smpi@siemens.com for part num-
ber and pricing.
5
1000 mm (39.37”).
Kit, Stainless steel rod 1330 mm (52.36”) to be See note 2. Note 3: For General Purpose approvals only.
used with CLS300 units only (with standard
active shield). Insertion length after installation is Note 4: To maintain approvals, qualified trained Siemens person-
1500 mm (59.06”). nel required for part replacement.
Kit, Stainless steel rod 1830 mm (72.05”) to be See note 2. Please contact nacc.smpi@siemens.com for special requests.
used with CLS300 units only (with standard
active shield). Insertion length after installation is
2000 mm (78.74”).
Kit, Stainless steel rod customized length up to See note 2.
1m
Kit, Stainless steel rod customized length up to See note 2.
2m
CLS300 Electronics Kits with drivers (for rod
or cable versions)
■ Overview Output
Output signal
• Alarm output Microswitch 5 A at 250 V AC, non
inductive
Microswitch SPDT contact 4 A at
30 V DC, non-inductive
• Pickup delay Standard (1 rpm model): approx
1.3 seconds
Optional process applications
(5 rpm model): approx. 0.26 sec-
onds
Sensitivity Adjustable via reset force of
spring or geometry of measuring
vane
Rated operating conditions
Installation conditions
• Location Indoor/outdoor
Ambient conditions
SITRANS LPS200 is a rotary paddle switch for level detection in • Ambient temperature -20 to +60 °C (-4 to +140 °F)
■ Benefits
• Pollution degree 2
Medium conditions Bulk solids
• Proven paddle switch technology for bulk solids
• Temperature
• High integrity mechanical seal
- Standard -20 to +80 °C (-4 to +176 °F)
• Optional switch selectable power supply
- Optional -20 to +350 °C (-4 to +662 °F)
• Unique friction clutch mechanism
• Pressure (vessel)
• Rotatable enclosure
- Standard Max. 0.5 bar (7.25 psi)
• Optional paddle for use with low density materials
- Optional Max. 10 bar (145 psi)
• Simple installation through process connection
• High temperature model and optional extension kit available • Minimum material density
• Optional fail-safe configuration - Standard measuring vane • 100 g/l (6.25 lb/ft3) when vane
and shaft covered by 10 cm (4")
of material
■ Application • 200 g/l (12.4 lb/ft3) when vane
and shaft covered by more than
The paddle switch technology detects full, empty or demand 10 cm (4") of material
conditions on materials such as grain, feed, cement, plastic
granulate and wood chips. The paddle switch can handle bulk - Optional measuring vane • 15 g/l (2.19 lb/ft3) when vane
densities as low as 15 g/l (2.19 lb/ft3) with the optional hinged and shaft covered by 10 cm (4”)
of material
vane or 100 g/l (6.25 lb/ft3) with the standard measuring vane.
• 20 g/l (4.69 lb/ft3) when vane
A low revolution geared motor with slip clutch drives a rotating and shaft covered by more than
measuring vane which senses the presence of material at the 10 cm (4") of material
mounted level of the LPS200. As material comes into contact Design
with the rotating paddle, rotation stops, which changes the mi-
croswitch state. When the paddle is no longer covered by ma- • Material
terial, rotation resumes and the relay reverts to its normal condi- - Enclosure Epoxy coated aluminum
tion.
- Process connection, measuring Stainless steel or aluminum
The LPS200 has a rugged design for use in harsh conditions in shaft and vane
the solids industry. The sensitivity of the paddle can be adjusted • Process connection Thread NPT, BSP and flange
for varying material properties like buildup on the vane. options
The LPS200 comes in a variety of configurations including com- • Degree of protection IP65/Type 4/NEMA 4
pact, extended and cable extension. It is equipped with a stan-
• Conduit entry 2 x M20x1.5 or 2 x ½" NPT
dard vane which is effective in most applications, but can be
configured with a hinged or rectangular vane for increased sen- Power supply
sitivity for light materials. • Jumper selectable • 115 V AC, ± 15%, 50 to 60 Hz,
• Key Applications: bulk solids such as grain, feed, cement, 4 VA or 230 V AC, ± 15%, 50 Hz,
plastic granulate, wood chips 6 VA, or 48 V AC, or 24 V AC
• or 24 V DC, ± 15%, 2.5 W
■ Technical specifications Certificates and approvals • CSA/FM General Purpose
Mode of operation • CE
• CSA/FM Dust Ignition Proof
Measuring principle Rotating point level switch
• ATEX II 1/2 D
Input
Measured variable High and low and demand
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, Extended 7ML 5 7 2 6 - SITRANS LPS200, Extended 7ML 5 7 2 6 -
Rotary paddle switch for level detection in bulk Rotary paddle switch for level detection in bulk
7 7 7 77 - 77 7 7 7 7 7 77 - 777 7
solids solids
Extended design with protection tube for added Extended design with protection tube for added
shaft protection shaft protection
Process temperature Measuring vane
Up to +80 °C (+176 °F) 1 Boot shaped, 35 x 106 mm (1.38 x 4.17”) A
Up to +150 °C (+302 °F) 2 Hinged vane, 65 x 210 mm (2.56 x 8.27”) B
Up to +250 °C (+482 °F) 3 Rectangular 50 x 150 mm (1.97 x 5.91”)7) D
Up to +350 °C (+662 °F)1) 4 Rectangular 50 x 250 mm (1.97 x 9.84”)7) E
Up to +80 °C (+176 °F) basic version2) and 3) } 5 Rectangular 98 x 150 mm (3.86 x 5.91”)7) F
Power supply Rectangular 98 x 250 mm (3.86 x 9.84”)7) G
230 V AC, 1 rev/min. A Approvals
230 V AC, 1 rev/min., fail-safe B CSA/FM Dust Ignition Proof, C-TICK 1
230 V AC, 5 rev/min. C ATEX II 1/2 D, C-TICK 2
230 V AC, 5 rev/min., fail-safe D CSA/FM General Purpose, C-TICK 3
115 V AC, 1 rev/min. E CE, C-TICK 4
115 V AC, 1 rev/min., fail-safe F Further designs Order code
115 V AC, 5 rev/min. G
5
Please add "-Z" to Order No. and specify Order
115 V AC, 5 rev/min., fail-safe H code(s).
48 V AC J
Heating of enclosure8) and 9) A35
24 V AC K Signal bulb inserted in M20 cable gland8) A20
24 V DC, 1 rev/min. L
SITRANS LPS200 designed for food applications K01
24 V DC, 1 rev/min., fail-safe M with shaft seal conforming to FDA standards
24 V DC, 5 rev/min. N Additional instruction manual Order No.
24 V DC, 5 rev/min., fail-safe P Multi-language 7ML1998-5FS62
Switch selectable 230 V AC/115 V AC/24 V DC Q This device is shipped with the Siemens Milltronics
multivoltage, 1 rev/min. manual CD containing the complete ATEX Quick
Switch selectable 230 V AC/115 V AC/24 V DC R Start and instruction manual library.
multivoltage, 5 rev/min.
Spare parts
Process connection Motor gear /PLC, multi-voltage 7ML1830-1KG
Threaded Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
G 1¼”[(BSPP), EN ISO 228-1] A (1.38 x 4.17”)
G 1½” [(BSPP), EN ISO 228-1] B Hinged vane, 65 x 210 mm (2.56 x 8.27”) 7ML1830-1KJ
1¼” NPT [(Taper), ANSI/ASME B1.20.1] C
1)
1½” NPT [(Taper), ANSI/ASME B1.20.1] D Available with approval option 3 and 4 only, up to max. 0.8 bar
2)
Available only with power supply option Q (process connection B with
Flanged approval 2 or process connection C with approval 1), process pressure 1,
DN32 PN 6, EN1092-1 (1.4541/321) E process connection material 2, extension length 2, protection tube B and
measuring vane A
DN100 PN 6, EN1092-1 (1.4541/321) F 3)
Basic version is cost effective and offers fast delivery.
DN100 PN 16, EN1092-1 (1.4541/321) G
4)
Available with process connections A to F only
2” ASME 150 lbs B16.5 (1.4541/321) H 5)
Available with process pressure option 1 only
3” ASME 150 lbs B16.5 (1.4541/321) J 6)
Available with process temperature option 1 only
4” ASME 150 lbs B16.5 (1.4541/321) K 7)
Available with process connections E, F, G, H, J, K only
Process pressure 8)
Available with approval options 3, 4 only
Up to 0.5 bar (7.25 psi) 1 9)
Available with power supply options A to H, J to N, P only
Up to 5 bar (72.5 psi) 2
Up to 10 bar (145 psi) 3 } Available ex stock.
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, cable extension 7ML 5 7 2 7 - SITRANS LPS200, cable extension 7ML 5 7 2 7 -
Rotary paddle switch for level detection in bulk 77 7 77 - 77 7 0
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 0
solids solids
Cable extension for increased length in Cable extension for increased length in
top-mounted applications top-mounted applications
Process temperature Measuring vane
Up to +80 °C (+176 °F) 1 Boot shaped, 35 x 106 mm (1.38 x 4.17”) A
Up to +150 °C (+302 °F) 2 Hinged vane, 65 x 210 mm (2.56 x 8.27”) B
Up to +250 °C (+482 °F) 3 Boot shaped, 28 x 98 mm (1.10 x 3.86”) C
Up to +350 °C (+662 °F)1) 4 Rectangular 50 x 150 mm (1.97 x 5.91”)6) D
Up to +80 °C (+176 °F) basic version2) and 3) } 5 Rectangular 50 x 250 mm (1.97 x 9.84”)6) E
Rectangular 98 x 150 mm (3.86 x 5.91”)6) F
Power supply
230 V AC, 1 rev/min. A Approvals
230 V AC, 1 rev/min., fail-safe B CSA/FM Dust Ignition Proof, C-TICK A
230 V AC, 5 rev/min. C ATEX II 1/2 D, C-TICK B
CSA/FM General Purpose, C-TICK C
230 V AC, 5 rev/min., fail-safe D
115 V AC, 1 rev/min. E CE, C-TICK D
115 V AC, 1 rev/min., fail-safe F Further designs Order code
115 V AC, 5 rev/min. G Please add "-Z" to Order No. and specify Order
115 V AC, 5 rev/min., fail-safe H code(s).
48 V AC
24 V AC
J
K
Total insertion length:
Enter the total insertion length in plain text descrip-
Y01
5
24 V DC, 1 rev/min. L tion, max. 10000 mm (393.70”)
24 V DC, 1 rev/min., fail-safe M Reinforced cable (max. 28 kN pulling force) P01
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, angled extension 7ML 5 7 2 8 - SITRANS LPS200, angled extension 7ML 5 7 2 8 -
Rotary paddle switch with robust design for level 77 7 77 - 77 7 0
Rotary paddle switch with robust design for level 7 7 7 77 - 77 7 0
detection in bulk solids detection in bulk solids
Angled extension designed to avoid falling material Angled extension designed to avoid falling material
in side mount applications in side mount applications
Process temperature Further designs Order code
Up to +80 °C (+176 °F) 1 Please add "-Z" to Order No. and specify Order
Up to +150 °C (+302 °F) 2 code(s).
Up to +250 °C (+482 °F) 3
Heating of enclosure1) and 2) A35
Power supply A20
Signal bulb inserted in M20 cable gland1)
230 V AC, 1 rev/min. A
230 V AC, 1 rev/min., fail-safe B Additional instruction manual Order No.
230 V AC, 5 rev/min. C Multi-language 7ML1998-5FS62
230 V AC, 5 rev/min., fail-safe D This device is shipped with the Siemens Milltronics
115 V AC, 1 rev/min. E manual CD containing the complete ATEX Quick
115 V AC, 1 rev/min., fail-safe F Start and instruction manual library.
5 24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
L
M
1)
2)
Available with approval options C, D only
Available with power supply options A to H, J to N, P only
24 V DC, 5 rev/min. N
24 V DC, 5 rev/min., fail-safe P
Switch selectable 230 V AC/115 V AC/24 V DC Q
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC R
multivoltage, 5 rev/min.
Process connection
Flanged
DN100 PN 6, EN1092-1 (1.4541/321) A
DN100 PN 16, EN1092-1 (1.4541/321) B
4” ASME 150 lbs B16.5 (1.4541/321) C
Process pressure
Up to 0.5 bar (7.25 psi) 1
Up to 5 bar (72.5 psi) 2
Up to 10 bar (145 psi) 3
Process connection material
Stainless steel 303 (1.4305) 1
Extension length
125 mm (4.92”) 1
150 mm (5.91”) 2
200 mm (7.87”) 3
250 mm (9.84”) 4
300 mm (11.81”) 5
Measuring vane
Rectangular vane, 50 x 98 mm (1.97 x 3.86”) A
Rectangular vane, 50 x 150 mm (1.97 x 5.91”) B
Rectangular vane, 50 x 250 mm (1.97 x 9.84”) C
Rectangular vane 98 x 150 mm (3.86 x 5.91”) D
Rectangular vane 98 x 250 mm (3.86 x 9.84”) E
Hinged vane, 65 x 210 mm (2.56 x 8.27”) F
Approvals
CSA/FM Dust Ignition Proof A
ATEX II 1/2 D B
CSA/FM General Purpose C
CE D
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, rigid extension 7ML 5 7 3 0 - SITRANS LPS200, rigid extension 7ML 5 7 3 0 -
Rotary paddle switch for level detection in bulk 77 7 77 - 77 77
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 7
solids solids
Process temperature Measuring vane
up to +80 °C (+176 °F) 1 Boot shaped, 35 x 106 mm (1.34 x 4.17”) A
up to +150 °C (+302 °F) 2 Hinged vane, 60 x 200 mm (2.36 x 7.87”) B
up to +250 °C (+482 °F) 3 Rectangular 50 x 150 mm (1.97 x 5.91”)5) C
up to +350 °C (+662 °F)1) 4 Rectangular 50 x 250 mm (1.97 x 9.84”)5) D
Power supply Rectangular 98 x 150 mm (3.86 x 5.91”)5) E
230 V AC, 1 rev/min. A Rectangular 98 x 250 mm (3.86 x 9.84”)5) F
230 V AC, 1 rev/min., fail-safe B Approvals
230 V AC, 5 rev/min. C CSA/FM Dust Ignition Proof 1
230 V AC, 5 rev/min., fail-safe D ATEX II 1/2 D 2
115 V AC, 1 rev/min. E CSA/FM General Purpose 3
115 V AC, 1 rev/min., fail-safe F CE 4
115 V AC, 5 rev/min. G Further designs Order code
115 V AC, 5 rev/min., fail-safe H Please add "-Z" to Order No. and specify Order
48 V AC J code(s).
24 V AC K Total insertion length: Enter the total insertion length Y01
5
24 V DC, 1 rev/min. L in plain text description, max. 4000 mm (157.48”)
24 V DC, 1 rev/min., fail-safe M
Heating of enclosure6) and 7) A35
24 V DC, 5 rev/min. N
Signal bulb inserted in M20 cable gland6) A20
24 V DC, 5 rev/min., fail-safe P
SITRANS LPS200 designed for food applications K01
Switch selectable 230 V AC/115 V AC/24 V DC Q with shaft seal conforming to FDA standards
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC R Seal at tube end for ingress protection and shaft
multivoltage, 5 rev/min. stability
Process connection - Max. temperature +80 °C (+176 °F) P06
Threaded - Max. temperature +150 °C (+302 °F) P07
G 1¼” [(BSPP), EN ISO 228-1] A
- Max. temperature +250 °C (+482 °F) P08
G 1½” [(BSPP), EN ISO 228-1] B
- Max. temperature +350 °C (+662 °F) P09
1¼” NPT [(Taper), ANSI/ASME B1.20.1] C
1½” NPT [(Taper), ANSI/ASME B1.20.1] D Sliding sleeve (standard, max. pressure 0.8 bar) P12
Flanged Sliding sleeve (pressure tight, for over-pressure P13
application starting from 1 bar max., dependent on
DN32 PN 6, EN1092-1 (1.4541/321) E pressure option ordered)
DN100 PN 6, EN1092-1 (1.4541/321) F
Additional instruction manual Order No.
DN100 PN 16, EN1092-1 (1.4541/321) G
Multi-language 7ML1998-5FS62
2” ASME 150 lbs B16.5 (1.4541/321) H
This device is shipped with the Siemens Milltronics
3” ASME 150 lbs B16.5 (1.4541/321) J
manual CD containing the complete ATEX Quick
4” ASME 150 lbs B16.5 (1.4541/321) K Start and instruction manual library.
Process pressure Spare parts
Up to 0.5 bar (7.25 psi) 1 Motor gear /PLC, multi-voltage 7ML1830-1KG
Up to 5 bar (72.5 psi) 2 Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
Up to 10 bar (145 psi) 3 (1.38 x 4.17”)
Process connection material Hinged vane, 65 x 210 mm (2.56 x 8.27”) 7ML1830-1KJ
Aluminum2) and 3) 1 1)
Available with approval option 3 and 4 only, up to max. 0.8 bar
Stainless steel 303 (1.4305) 2 2)
Available with process connections A to D only
Extension material (protection tube) 3)
Available with process pressure option 1 only
Aluminum2) and 4) 0 4)
Stainless steel 303 (1.4305) 1 Available with process connection material option 1 only
5)
Available with process connections E to H, J, K only
Extension length 6)
165 to 500 mm (6.50 to 9.69”) A Available with approval options 3, 4 only
7)
501 to 750 mm (19.72 to 29.53”) B Available with power supply options A to H, J to N, P only
751 to 1000 mm (29.57 to 39.37”) C
1001 to 1250 mm (39.41 to 42.21”) D
1251 to 1500 mm (49.25 to 59.06”) E
1501 to 1750 mm (59.09 to 68.90”) F
1751 to 2000 mm (68.94 to 78.74”) G
2001 to 2250 mm (78.78 to 88.58”) H
2251 to 2500 mm (88.62 to 98.43”) J
2501 to 2750 mm (98.46 to 108.27”) K
2751 to 3000 mm (108.31 to 118.11”) L
3001 to 3250 mm (118.15 to 127.95”) M
3251 to 3500 mm (127.99 to 137.80”) N
3501 to 3750 mm (137.83 to 147.64”) P
3751 to 4000 mm (147.67 to 157.48”) Q
■ Dimensional drawings
■ Schematics
Design
approx. 5 g/l (0.3 lb/ft3)
5
• Material
- Enclosure Epoxy coated aluminum
• Process connection • Thread 1½” NPT [(Taper),
ANSI/ASME B1.20.1], R 1½”
[(BSPT), EN 10226] and flange
options
• Optional sliding bushing with
2” NPT [(Taper), ANSI/ASME
B1.20.1] or BSP thread
• Thread material: stainless steel
303 (1.4301)
• Tine material Stainless steel 316TI (1.4571),
PTFE-coated tines are available
upon special request
• Degree of protection IP65/Type 4/NEMA 4
• Conduit entry 2 x M20x1.5 or 2 x ½" NPT
• Weight • Standard version, no exten-
sions: approx 2.0 kg (4.4 lbs)
• Solids/liquids version, no exten-
sions: approx. 1.9 kg (4.2 lbs)
Power supply • 19 to 230 V AC, +10%, 50 to
60 Hz, 8 VA
• 19 to 55 V DC, +10%, 1.5 W
Certificates and approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• ATEX II 1/2 D
• CSA/FM IS Class I, II, III Div. 1,
Groups A, B, C, D, E, F, G, FM
Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with
power supply option 5
• ATEX II 1G and 1/2 G Eex ia IIC;
ATEX II 1D and 1/2 D, available
only with power supply option 5
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, standard 7ML 5 7 3 1 - SITRANS LVS200, standard 7ML 5 7 3 1 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
bulk solids bulk solids
Power supply • 1251 to 1500 mm (49.25 to 59.06”)8) 36
19 to 230 V AC, 19 to 55 V DC, one relay output 1 • 1501 to 1750 mm (59.09 to 68.90”)8) 37
(SPDT)
• 1751 to 2000 mm (68.94 to 78.74”)8) 38
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2
(DPDT) • 2001 to 2250 mm (78.78 to 88.58”)8) 41
18 to 50 V DC PNP 3 • 2251 to 2500 mm (88.62 to 98.43”)8) 42
19 to 230 V AC/DC without contact, 2-wire loop 4 • 2501 to 2750 mm (98.46 to 108.27”)8) 43
powered1) • 2751 to 3000 mm (108.31 to 118.11”)8) 44
7 to 9 V DC (requires NAMUR switch amplifier) 5 • 3001 to 3250 mm (118.15 to 127.95”)8) 45
NAMUR IEC 60947-5-6, 2-wire2) • 3251 to 3500 mm (127.99 to 137.80”)8) 46
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire3) 6 • 3501 to 3750 mm (137.83 to 147.64”)8) 47
19 to 230 V AC, 19 to 55 V DC, one relay output } 7 • 3751 to 4000 mm (147.68 to 157.48”)8) 48
(SPDT) basic version4) and 5)
Material process connection/extension
Process temperature
Stainless steel 304 (1.4301) 1
Without temperature isolator A
Stainless steel 316 TI (1.4571) 2
With temperature isolator B
Approvals
Separated enclosure - cable length 1.5 m (4.92 ft) C
5 [max. temperature process +180 °C (+356 °F)/max. CSA/FM Dust Ignition Proof A
temperature electronics +80 °C (+176 °F)] ATEX II 1/2 D B
Separated enclosure - cable length 4.0 m (13.12 ft) D CSA/FM General Purpose C
[max. temperature process +180 °C CE D
(+356 °F)/max. temperature electronics +80 °C
(+176 °F)] CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
Process connection IIC9)
Threaded ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
R 1½" [(BSPT), EN 10226] A 1/2D9)
1½" NPT [(Taper), ANSI/ASME B1.20.1] B Further designs Order code
G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. C
Please add “-Z” to Order No. and specify Order
length 500 mm (19.69”)]6)
code(s).
2" NPT [(Taper), ANSI/ASME B1.20.1] , sliding D
sleeve [min. length 500 mm (19.69”)]6) Total insertion length: Enter the total insertion length Y01
Flanged in plain text description, max. 4000 mm (157.48”)
DN100 PN 6, EN1092-1 (1.4541/321) E Enhanced sensitivity > 5 g/l via electronics and K05
increased fork length to 195 mm (7.68”)
DN100 PN 16, EN1092-1 (1.4541/321) F
Enhanced sensitivity < 5 g/l via electronics, G01
2” ASME 150 lbs B16.5 (1.4541/321) G increased fork length to 195 mm (7.68”), and
3” ASME 150 lbs B16.5 (1.4541/321) H increased aluminum fork width (available only with
4” ASME 150 lbs B16.5 (1.4541/321) J universal voltage, SPDT, CE/FM and CSA General
Purpose approvals)
Extension length
Signal bulb inserted in M20 cable gland10) A20
Stainless steel 304 (1.4301)
NAMUR 8/16 mA switch amplifiers A15
Standard length, 230 mm (9.06”)7) 11
Add order code Y01 and plain text: “Insertion Instruction manual Order No.
length ... mm” Multi-language 7ML1998-5FT62
• 300 to 500 mm (11.81 to 19.69”)7) 12
This device is shipped with the Siemens Milltronics
• 501 to 750 mm (19.72 to 29.53”)7) 13 manual CD containing the complete ATEX Quick
• 751 to 1000 mm (29.57 to 39.37”)7) 14 Start and instruction manual library.
• 1001 to 1250 mm (39.41 to 49.21”)7) 15 Spare parts
• 1251 to 1500 mm (49.25 to 59.06”)7) 16 Replacement Electronics Module (125 Hz) 7ML1830-1KL
• 1501 to 1750 mm (59.09 to 68.90”)7) 17 [19 to 230 V AC, 19 to 55 V DC, one relay output
(SPDT)]
• 1751 to 2000 mm (68.94 to 78.74”)7) 18
Sliding sleeve, 2” BSP (ISO 228) 7ML1830-1JM
• 2001 to 2250 mm (78.78 to 88.58”)7) 21
Sliding sleeve, 2” NPT [(Taper), ANSI/ASME 7ML1830-1JN
• 2251 to 2500 mm (88.62 to 98.43”7) 22 B1.20.1]
• 2501 to 2750 mm (98.46 to 108.27”)7) 23 1)
Available with approval options A, B, C, D, E only
• 2751 to 3000 mm (108.31 to 118.11”)7) 24
2)
• 3001 to 3250 mm (118.15 to 127.95”)7) 25 Available with approval options E, F only
3)
Available with approval option D only
• 3251 to 3500 mm (127.99 to 137.80”)7) 26 4)
Available only with process temperature option A (process connection A
• 3501 to 3750 mm (137.83 to 147.64”)7) 27 with approval option B, or process connection B with approval option A),
• 3751 to 4000 mm (147.68 to 157.48”)7) 28 extension length 11 and material process connection 1
Stainless Steel 316TI (1.4571) 5)
Basic version is cost effective and offers fast delivery.
Standard length, 230 mm (9.06”)8) 31 6)
Not available with extension length options 11 and 12
Add order code Y01 and plain text: “Insertion 7)
Available with Material process connection/extension option 1 only
length ...mm” 8)
Available with Material process connection/extension option 2 only
• 300 to 500 mm (11.81 to 19.69”)8) 32
9)
• 501 to 750 mm (19.72 to 29.53”)8) 33 Available with power supply option 5 only
10)
• 751 to 1000 mm (29.57 to 39.37”)8) 34 Available with approval options C, D only
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, liquids/solids interface 7ML 5 7 3 2 - SITRANS LVS200, liquids/solids interface 7ML 5 7 3 2 -
Vibrating point level switch for interface applica- Vibrating point level switch for interface applica-
77 7 77 - 77 A 0 77 7 77 - 77 A 0
tions, and high load applications with short inser- tions, and high load applications with short inser-
tion requirements tion requirements
Power supply 1251 to 1500 mm (49.25 to 59.06”)4) 36
19 to 230 V AC, 19 to 55 V DC, one relay output 1 1501 to 1750 mm (59.09 to 68.90”)4) 37
(SPDT)
1751 to 2000 mm (68.94 to 78.74”)4) 38
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2
(DPDT) 2001 to 2250 mm (78.78 to 88.58”)4) 41
18 to 50 V DC PNP 3 2251 to 2500 mm (88.62 to 98.43”)4) 42
19 to 230 V AC/DC without contact, 2-wire loop 4 2501 to 2750 mm (98.46 to 108.27”)4) 43
powered1) 2751 to 3000 mm (108.31 to 118.11”)4) 44
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire2) 5 3001 to 3250 mm (118.15 to 127.95”)4) 45
Process temperature 3251 to 3500 mm (127.99 to 137.80”)4) 46
Without temperature isolator A 3501 to 3750 mm (137.83 to 147.64”)4) 47
With temperature isolator B 3751 to 4000 mm (147.68 to 157.48”)4) 48
Separated enclosure - cable length 1.5 m (4.92 ft) C Material process connection/extension
[max. temperature process +180 °C Stainless steel 304 (1.4301) 1
(+356 °F)/max. temperature electronics +80 °C Stainless steel 316 TI (1.4571) 2
(+176 °F)]
5
Separated enclosure - cable length 4.0 m (13.12 ft) D Approvals
[max. temperature process +180 °C CSA/FM Dust Ignition Proof A
(+356 °F)/max. temperature electronics +80 °C ATEX II 1/2 D B
(+176 °F)] CSA/FM General Purpose C
Process connection CE D
Threaded Further designs Order code
R 1½" [(BSPT), EN 10226] A
Please add “-Z” to Order No. and specify Order
1½" NPT [(Taper), ANSI/ASME B1.20.1] B code(s).
G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. C
length 500 mm (19.69”)] Total insertion length: Enter the total insertion length Y01
in plain text description, max. 4000 mm (157.48”)
2" NPT [(Taper), ANSI/ASME B1.20.1], sliding D A20
sleeve Signal bulb inserted in M20 cable gland5)
[min. length 500 mm (19.69”)] Instruction manual Order No.
Flanged Multi-language 7ML1998-5FT62
DN100 PN 6, EN1092-1 (1.4541/321) E
This device is shipped with the Siemens Milltronics
DN100 PN 16, EN1092-1 (1.4541/321) F
manual CD containing the complete ATEX Quick
2” ASME 150 lbs B16.5 (1.4541/321) G Start and instruction manual library.
3” ASME 150 lbs B16.5 (1.4541/321) H Spare parts
4” ASME 150 lbs B16.5 (1.4541/321) J Replacement Electronics Module (350 Hz) 7ML1830-1KM
Extension length [19 to 230 V AC, 19 to 55 V DC, one relay output
(SPDT)]
Stainless steel 304 (1.4301)3)
Sliding sleeve, 2” [(BSPP), EN ISO 228-1] 7ML1830-1JM
Standard length, 165 mm (6.50”) 11
Sliding sleeve, 2” NPT [(Taper), ANSI/ASME B1.20.1] 7ML1830-1JN
Add order code Y01 and plain text: “Insertion
length ... mm” 1)
Available with approval options B, C, D only
200 to 500 mm (7.87 to 19.69”)3) 12 2)
Available only with approval option D only
501 to 750 mm (19.72 to 29.53”)3) 13 3)
Available with material process connection/extension option 1 only
751 to 1000 mm (29.57 to 39.37”)3) 14 4)
Available with material process connection/extension option 2 only
1001 to 1250 mm (39.41 to 49.21”)3) 15 5)
Available with approval options C, D only
1251 to 1500 mm (49.25 to 59.06”)3) 16
1501 to 1750 mm (59.09 to 68.90”)3) 17
1751 to 2000 mm (68.94 to 78.74”)3) 18
2001 to 2250 mm (78.78 to 88.58”)3) 21
2251 to 2500 mm (88.62 to 98.43”3) 22
2501 to 2750 mm (98.46 to 108.27”)3) 23
2751 to 3000 mm (108.31 to 118.11”)3) 24
3001 to 3250 mm (118.15 to 127.95”)3) 25
3251 to 3500 mm (127.99 to 137.80”)3) 26
3501 to 3750 mm (137.83 to 147.64”)3) 27
3751 to 4000 mm (147.68 to 157.48”)3) 28
Stainless Steel 316TI (1.4571)
Standard length, 165 mm (6.50”)4) 31
Add order code Y01 and plain text: “Insertion
length ...mm”
200 to 500 mm (7.87 to 19.69”) 4) 32
501 to 750 mm (19.72 to 29.53”)4) 33
751 to 1000 mm (29.57 to 39.37”)4) 34
1001 to 1250 mm (39.41 to 49.21”)4) 35
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, pipe extension 7ML 5 7 3 3 - SITRANS LVS200, pipe extension 7ML 5 7 3 3 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
77 7 77 - 77 A 0 7 7 7 77 - 77 A 0
bulk solids bulk solids
Extended using 1” pipe extension (customer sup- Extended using 1” pipe extension (customer sup-
plied) plied)
Power supply Instruction manual
19 to 230 V AC, 19 to 55 V DC, one relay output 1 Multi-language 7ML1998-5FT62
(SPDT) Note: One instruction manual is shipped with this
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2 product.
(DPDT) This device is shipped with the Siemens Milltronics
18 to 50 V DC PNP 3 manual CD containing the complete ATEX Quick
19 to 230 V AC/DC without contact, 2-wire loop 4 Start and instruction manual library.
powered1) Spare parts
7 to 9 V DC (requires NAMUR switch amplifier) 5 Replacement Electronics Module (125 Hz) 7ML1830-1KL
NAMUR IEC 60947-5-6, 2-wire2) [19 to 230 V AC, 19 to 55 V DC, one relay output
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire3) 6 (SPDT)]
Process temperature Replacement Electronics Module (350 Hz) 7ML1830-1KM
[19 to 230 V AC, 19 to 55 V DC, one relay output
Up to +150 °C (+302 °F) A (SPDT)]
Process connection 1)
Available with approval options A, B, C, D, E only
Threaded
5
2)
Available with approval options C, D, E and F only
R 1½" [(BSPT), EN 10226] A 3)
Available with approval option D only
1½" NPT [(Taper), ANSI/ASME B1.20.1] B 4)
Available with power supply option 5 only
Flanged 5)
Available with approval options C, D only
DN100 PN 6, EN1092-1 (1.4541/321) C
DN100 PN 16, EN1092-1 (1.4541/321) D
2” ASME 150 lbs B16.5 (1.4541/321) E
3” ASME 150 lbs B16.5 (1.4541/321) F
4” ASME 150 lbs B16.5 (1.4541/321) G
Process connection material
Stainless steel 304 (1.4301) 1
Stainless steel 316 TI (1.4571) 2
Extension length
Customer supplied 1” pipe extension 1
Length: 300 to 3800 mm (11.81 to 149.61”)
Application type
Dry bulk solids (125 Hz) 1
Liquids/solids interface (350 Hz) 2
Approvals
CSA/FM Dust Ignition Proof A
ATEX II 1/2 D B
CSA/FM General Purpose C
CE D
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
IIC4)
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
1/2D4)
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Enter the total insertion length in plain text descrip- Y01
tion, min. 300 mm (11.81”) max. 3800 mm (149.61”)
Enhanced sensitivity > 5 g/l via electronics and K05
increased fork length to 195 mm (7.68 “)
Signal bulb inserted in M20 cable gland5) A20
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, cable extended 7ML 5 7 3 4 - SITRANS LVS200, cable extended 7ML 5 7 3 4 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
bulk solids bulk solids
Power supply Approvals
19 to 230 V AC, 19 to 55 V DC, one relay output 1 CSA/FM Dust Ignition Proof A
(SPDT) ATEX II 1/2 D B
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2 CSA/FM General Purpose C
(DPDT)
18 to 50 V DC PNP 3 CE D
19 to 230 V AC/DC without contact, 2-wire loop 4 CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
powered1) E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
IIC6) and 7)
7 to 9 V DC (requires NAMUR switch amplifier) 5
NAMUR IEC 60947-5-6, 2-wire2) and 3) ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire4) 6 1/2D and 5)
Process temperature Further designs Order code
Up to +80 °C (+176 °F) A Please add “-Z” to Order No. and specify Order
Process connection code(s).
Threaded Enter the total insertion length in plain text descrip- Y01
R 1½" [(BSPT), EN 10226] A tion, max. 20000 mm (787.40“)
1½" NPT [(Taper), ANSI/ASME B1.20.1] B
5
Enhanced sensitivity > 5 g/l via electronics and K05
increased fork length to 195 mm (7.68“)
Flanged
Signal bulb inserted in M20 cable gland4) A20
DN100 PN 6, EN1092-1 (1.4541/321) C
DN100 PN 16, EN1092-1 (1.4541/321) D NAMUR 8 to 16 mA switch amplifiers A15
2” ASME 150 lbs B16.5 (1.4541/321) E Instruction manual Order No.
3” ASME 150 lbs B16.5 (1.4541/321) F Multi-language 7ML1998-5FT62
4” ASME 150 lbs B16.5 (1.4541/321) G This device is shipped with the Siemens Milltronics
Extension length manual CD containing the complete ATEX Quick
Start and instruction manual library.
500 to 1000 mm (19.7 to 39.4”) [max. length 10
20000 mm (787.4”), not with Power supply option 5 Spare parts
(max. 10000 mm, 393.7”)] Replacement Electronics Module (125 Hz) 7ML1830-1KL
Add order code Y01 and plain text: “Insertion [19 to 230 V AC, 19 to 55 V DC, one relay output
length ... mm” (SPDT)]
1001 to 2000 mm (39.41 to 78.74”) 11 Replacement Electronics Module (350 Hz) 7ML1830-1KM
2001 to 3000 mm (78.78 to 118.11”) 12 [19 to 230 V AC, 19 to 55 V DC, one relay output
(SPDT)]
3001 to 4000 mm (118.15 to 157.48”) 13
1) Available with approval options A, B, C, D, E only
4001 to 5000 mm (157.52 to 196.85”) 14
2) Available with approval options C, D, E and F only
5001 to 6000 mm (196.89 to 236.22”) 15
3) Cable length is limited to 10000 mm (393.70”)
6001 to 7000 mm (236.26 to 275.59”) 16
4) Available with approval options C, D only
7001 to 8000 mm (275.63 to 314.96”) 17
5) Cable length is limited to 7000 mm (275.59”)
8001 to 9000 mm (315 to 354.33”) 18
6) Available with power supply option 5 only
9001 to 10000 mm (354.37 to 393.70”) 20 7)
10001 to 11000 mm (393.74 to 433.07”) 21 Available with application type 1 only
11001 to 12000 mm (433.11 to 472.44”) 22
12001 to 13000 mm (472.48 to 511.81”) 23
13001 to 14000 mm (511.85 to 551.18”) 24
14001 to 15000 mm (551.22 to 590.55”) 25
15001 to 16000 mm (590.59 to 629.92”) 26
16001 to 17000 mm (629.96 to 669.29”) 27
17001 to 18000 mm (669.33 to 708.66”) 28
18001 to 19000 mm (708.70 to 748.03”) 30
19001 to 20000 mm (748.07 to 787.40”) 31
Application type
Dry bulk solids (125 Hz) 1
Liquid/solids interface (350 Hz)5) 2
■ Dimensional drawings
■ Schematics
■ Technical specifications
Ultrasonics Transmitter/Controller Selection Guide
Criteria SITRANS HydroRanger MultiRanger SITRANS LUC500 SITRANS LU OCM III
Probe LU 200 100/200
Range 6 m (20 ft) or 15 m (50 ft) trans- 15 m (50 ft) trans- 15 m (50 ft) trans- 60 m (200 ft) trans- 3 m (10 ft)
12 m (40 ft) ducer and applica- ducer and applica- ducer and applica- ducer and applica-
tion dependent tion dependent tion dependent tion dependent
Typical applications Chemical storage Wet wells, Wet wells, Wet well/lift station Chemical storage, Open channel mea-
vessels, filter beds, flumes/weirs, bar flumes/weirs, bar control, liquid storage, bulk surement
liquid storage ves- screen control screen control, hop- weirs/flumes, open solids storage
sels pers, chemical stor- channels (sugar, flour bins,
age, liquid storage, grains, cereals),
crusher bins, dry plastic pellets
solids storage
Output HART model: 6 relays standard, 1 relay (option on 5 relays, 4 to 20 mA 4 relays (LU01, 3 relays, 4 to 20 mA
4 to 20 mA/HART two 4 to 20 mA out- MultiRanger 100) (option) LU02)
PROFIBUS PA puts (isolated) 3 relays standard Up to 40 relays
model: PROFIBUS 6 relays (option) (LU10)
Two 4 to 20 mA out- 4 to 20 mA isolated
puts (isolated)
Communications HART or
PROFIBUS PA
Built-in Modbus
RTU/ASCII via
RS-485
Built-in Modbus
RTU or ASCII via
RS-485
Telemetry capability
with Modbus
RTU/ASCII via
Dolphin, RS-232/
RS-485 (LU01,
LU02)
Via RS-232
Options:
5
Options: • Flow Reporter
Options: Options: RS-232/RS-485 Dolphin via infrared
• SIMATIC PDM for software
remote configura- • SIMATIC PDM • SIMATIC PDM Options: (LU10)
tion and diagnos- • SmartLinx • Smartlinx • SIMATIC PDM Options:
tics (PROFIBUS DP, (PROFIBUS DP, • SmartLinx • SmartLinx
Allen-Bradley Re- Allen-Bradley Re- (PROFIBUS DP, (PROFIBUS DP,
mote I/O, mote I/O, Allen-Bradley Re- Allen-Bradley Re-
DeviceNet) DeviceNet) mote I/O, mote I/O,
DeviceNet) DeviceNet)
• ECT EnviroRanger
Tool software
Power specifica- HART: 4 to 20 mA, AC version: 100 to AC version: 100 to AC version: 100 to LU01, LU02: 100/115/200/230 V
tions 24 V DC nominal, 230 V AC ±15%, 230 V AC ±15%, 230 V AC ±15%, AC version: AC, ±15%,
max. 550 Ω, 50/60 Hz, 50/60 Hz, 50/60 Hz, 100/115/200/ 50/60 Hz, 15 VA
30 V DC max. 36 VA/17 W 36 VA/17 W 30 VA/17 W 230 V AC and/or
PROFIBUS PA: 12, DC version: 12 to DC version: 12 to DC version: 12 to DC version: 18 to 9 to 30 V DC, 8 W
13, 15, or 20 mA, 30 V DC, 20 W 30 V DC, 20 W 30 V DC, 20 W 30 V DC, 25 W
dependent on pro-
gramming LU10: 100/115/200/
230 V AC
Approvals CE, CSANRTL/C, FM, CE, CSANRTL/C, CE, CSANRTL/C, CE, CSANRTL/C, CE, CSANRTL/C, FM, CE, CSANRTL/C, FM
ATEX, ANZEx, UL Listed, FM UL Listed, FM UL Listed Lloyd’s Register
IECEx
E-mail: Fax: ( )
Open channel
Conical Conical
Parabolic Parabolic
Material
Material being measured: Liquid Solid
Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-769R2
■ Configuration
■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting de-
vices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water and wastewater industries. A
sanitary version of the ULS200, with an industry standard flange
option, is easy to remove from the application for cleaning. It
thus satisfies the prerequisites for use in the food, beverage and
pharmaceutical industries. The Pointek ULS200 delivers supe-
rior performance while reducing maintenance, downtime and
equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
Pointek ULS200 Mounting
■ Design
Installation
The Pointek ULS200 should be mounted in an area that is within
the temperature range specified and that is suitable to the enclo-
sure rating and materials of construction. The cover should be
accessible to allow programming, wiring and display viewing.
It is advisable to keep the Pointek ULS200 away from high volt-
age or current runs, contactors and SCR control drives.
Locate the Pointek ULS200 so that it has a clear sound path per-
pendicular to the material surface. The sound path should not in-
tersect the fill path, rough walls, seams, rungs etc.
Threaded mounting 2“ NPT [(Taper), ANSI/ASME Additional Multi-language Quick Start manual C) 7ML1998-1XB81
B1.20.1]
R 2“ [(BSPT), EN 10226] This device is shipped with the Siemens Milltronics
or G 2” [(BSPP), EN ISO 228-1] manual CD containing the complete ATEX Quick
Start and instruction manual library.
• Optional flange adapter For 3“ ASME, DN 65, PN10 and
JIS 10 K3B Accessories
Sanitary mounting 4” sanitary fitting clamp accord- Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
ing to 3A guidelines text line, suitable for enclosures
Universal Box Bracket Mounting Kit 7ML1830-1BK
Power supply
3” ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
AC version 100 to 230 V AC, ± 15%,
adapter for 2” NPT
50/60 Hz, max. 12 VA, 5 W
3” ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
DC version 18 to 30 V DC, 3 W adapter for 2” BSPT
Displays and controls 2" BSPT Locknut, plastic 7ML1830-1DQ
Display LCD, three digits, 9 mm (0.35“) 2” NPT Locknut 7ML1830-1DT
high, for display of distance
4” sanitary mounting clamp 7ML1830-1BR
between sensor face and mate-
rial, multisegment graphic for Spare Parts
operating state
Polycarbonate Lid 7ML1830-1LG
Memory EEPROM, non-volatile
Aluminum Lid 7ML1830-1LH
Programming 2 keys
1) Available with enclosure/cable inlet option 4 only
Electronics/enclosure Connection: terminal block, max.
2.5 mm2 (14 AWG) solid/1.5 mm2 2) Available with enclosure/cable inlet option 4 only and process connection
(16 AWG) stranded options A and E only
3)
Degree of protection IP67/Type 6/NEMA 6 Available with enclosure/cable inlet options 2 and 4 only
4) Available with approval option H only
Cable inlet 2 x ½“ NPT or 2 x PG 13.5
Certificates and approvals • CE (EMC certificate available on C) Subject to export regulations AL: N, ECCN: EAR99
request), CSANRTL/C, FM
• CSA/FM Class I, Div. 1,
Groups A, B, C, D; Class II;
Groups E, F, G; Class III
• ATEX II 2G EEx md II C T5
• 3A Approval
■ Options ■ Schematics
■ Dimensional drawings
■ Overview ■ Configuration
■ Benefits
• Easy to install, program and maintain
• Accurate and reliable
• Sanitary models available
• Patented Sonic Intelligence® echo processing
• Integral temperature compensation
■ Application
The transducer is available in PVDF copolymer, making the de-
vice suitable for use in a wide variety of applications. The Probe
is easy to install and maintain, and can be quickly removed for
cleaning as required by the food, beverage and pharmaceutical
industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between the
true echo and false echoes from acoustic or electrical noises
and agitator blades in motion. The ultrasonic pulse propagation
time to the material and back is temperature-compensated and
converted into distance for display, analog output and relay
actuation.
• Key Applications: chemical storage vessels, filter beds, mud
pits, liquid storage vessels, food applications
The Probe mounting
■ Overview ■ Configuration
■ Application
The SITRANS Probe LU is ideal for level monitoring in the water
and wastewater industry and chemical storage vessels.
The range of SITRANS Probe LU is 6 or 12 meters (20 or 40 feet).
Using Auto False-Echo Suppression for fixed obstruction avoid-
ance, as well as an improved signal-to-noise ratio and improved
accuracy of 0.15% of range or 6 mm (0.25”), the Probe LU pro-
vides unmatched reliability.
SITRANS Probe LU includes Sonic Intelligence® signal process- SITRANS Probe LU mounting
ing from the field-proven Milltronics Probe and incorporates new
echo processing features and the latest micro-processor and
communications technology. The Probe LU offers two communi-
cations options: HART or PROFIBUS PA (Profile version 3.0,
Class B).
The transducer on the Probe LU is available as ETFE or PVDF to
suit the chemical conditions of your application. As well, for ap-
plications with varying material and process temperatures, the
Probe LU incorporates an internal temperature sensor to com-
pensate for temperature changes.
• Key Applications: chemical storage vessels, filter beds, liquid
storage vessels
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS Probe LU C) 7 M L 5 2 2 1 - SITRANS Probe LU C) 7 M L 5 2 2 1 -
2-wire, loop powered ultrasonic transmitter for 7 7 7 77 2-wire, loop powered ultrasonic transmitter for 7 7 7 77
level, volume and flow monitoring of liquids in open level, volume and flow monitoring of liquids in open
channels, storage vessels and simple process ves- channels, storage vessels and simple process ves-
sels. sels.
Enclosure/Cable Inlet Instruction manual for HART/mA device
Plastic (PBT), 2 x M20x1.5 (check Approvals for 1 English C) 7ML1998-5HT02
cable gland details) French C) 7ML1998-5HT11
Plastic (PBT), 2 x ½” NPT (no cable glands sup- 2 German C) 7ML1998-5HT32
plied) Note: The instruction manual should be ordered as
Range/Transducer material a separate item on the order.
6 meter (20 ft), ETFE A Additional Multi-language Quick Start manual C) 7ML1998-5QR81
6 meter (20 ft), PVDF Copolymer B
12 meter (40 ft), ETFE C This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
12 meter (40 ft), PVDF Copolymer D
Start and instruction manual library.
Process connection
Instruction manual for PROFIBUS PA device
2” NPT [(Taper), ANSI/ASME B1.20.1] A
English C) 7ML1998-5JB02
R 2” [(BSPT), EN 10226] B
German C) 7ML1998-5JB32
G 2” [(BSPP), EN ISO 228-1] C Note: The instruction manual should be ordered as
Communication/Output a separate item on the order.
4 to 20 mA, HART® Additional Multi-language Quick Start manual C) 7ML1998-5QV81
5
1
PROFIBUS PA 2
Approvals This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
General Purpose, FM, CSA, CE 1
Start and instruction manual library.
Intrinsically Safe, FM Class I, Div. 1, Groups A, B, 2
C, D (barrier required); Class II, Div. 1, Groups E, F, Optional equipment
G; Class III; ATEX II 1G EEx ia IIC T4, ANZEx, Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH
IECEx (HART model only) Handheld programmer, General Purpose approvals 7ML1830-2AN
Intrinsically Safe, CSA Class I, Div. 1, Groups A, B, 3
C, D (barrier required); Class II, Div. 1, Group G; Handheld programmer, Infrared, Intrinsically Safe, C) 7ML5830-2AJ
Class III (HART model only) PROFIBUS PA
FM, Class l, Div. 2 (Enclosure option 2 only) 4 HART modem/RS-232 (for use with PC and D) 7MF4997-1DA
Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A, 5 SIMATIC PDM)
B, C, D (barrier required); Class II, Div. 1, Groups E, HART modem/USB (for use with a PC and D) 7MF4997-1DB
F, G; Class III (PROFIBUS PA model only) SIMATIC PDM)
Intrinsically Safe, ATEX II 1G EEx ia IIC T4 6 2" NPT locknut, plastic 7ML1830-1DT
(PROFIBUS PA model only) 2" BSPT locknut, plastic 7ML1830-1DQ
Further designs Order code 3” ASME, DIN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
Please add “-Z” to Order No. and specify Order adapter for 2” NPT
code(s). 3” ASME, DIN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15 adapter for 2” BSPT
Measuring-point number/identification (max. 16 One General Purpose polymeric cable gland 7ML1930-1AM
characters) specify in plain text M20x1.5, rated for -20 to +80 °C (-4 to +176 °F)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
+80 °C (-40 to +176 °F) for General Purpose or
ATEX EEx e installations (available for HART only)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
nection (available for PROFIBUS PA)
Spare Parts
Plastic lid C) 7ML1830-1KB
■ Options
■ Dimensional drawings
■ Schematics
Connect the
wires to the
terminals as
shown: the
lid screws terminals for polarity is
loop current identified on
or PROFIBUS PA the terminal block.
cable
cable
watertight gland
Notes:
- HART model above is shown with M20 cable glands. ½” NPT threaded connection is also available.
- DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
- All field wiring must have insulation suitable for rated input voltages.
- Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
5
XRS-5
Relays1) Rating 5 A at 250 V AC, non-
inductive
• Model with 1 relay2) 1 SPST Form A
• Model with 3 relays2) 2 SPST Form A/1 SPDT Form C
HydroRanger 200 is an ultrasonic level controller for up to six • Model with 6 relays 4 SPST Form A/2 SPDT Form C
pumps and provides control, differential control and open chan- mA output 0 to 20 mA or 4 to 20 mA
nel flow monitoring.
• Max. load 750 Ω, isolated
■ Benefits • Resolution
Accuracy
0.1% of range
HydroRanger 200 uses proven continuous ultrasonic echo rang- • Panel mount IP54/Type 3/NEMA 3
ing technology to monitor water and wastewater of any consis- Cable
tency up to 15 m (50 ft) in depth. Achievable resolution is 0.1% Transducer and mA output signal 2-core copper conductor, twisted,
with accuracy to 0.25% of range. Unlike contacting devices, Hy- shielded, 300 Vrms, 0.82 mm²
droRanger 200 is immune to problems caused by suspended (18 AWG), Belden® 8760 or
solids, harsh corrosives, grease or silt in the effluent, reducing equivalent is acceptable
downtime. Max. separation between trans- 365 m (1200 ft)
• Key Applications: wet wells, flumes/weirs, bar screen control ducer and transceiver
Selection and Ordering data Order No. Selection and Ordering data Order No.
Siemens HydroRanger 200 C) 7 M L 5 0 3 4 - Siemens HydroRanger 200 C) 7 M L 5 0 3 4 -
Ultrasonic level controller for up to six pumps that Ultrasonic level controller for up to six pumps that
77 7 77 777 77
provides control, differential control and open provides control, differential control and open
channel flow monitoring channel flow monitoring
Mounting Accessories
Wall mount, standard enclosure 1 Handheld programmer 7ML1830-2AK
Wall mount, 4 entries, 4 M20 cable glands included 2 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Panel mount1) 3 text line, suitable for enclosure
Power supply TS-3 Temperature Sensor - see TS-3 on page 5/144
100 to 230 V AC A Spare parts
12 to 30 V DC B Power Supply Board (100 to 230 V AC) C) 7ML1830-1MD
Number of measurement points Power Supply Board (12 to 30 V DC) C) 7ML1830-1ME
Single point model, 6 relays A Display Board C) 7ML1830-1MF
Dual point model, 6 relays B See SmartLinx product page 5/250 for more infor-
Single point model, level only, 1 relay2) C mation.
Single point model, level only, 3 relay2) D 1)
Available with approval option 1 only.
Communication (SmartLinx) 2)
This model is level control only; no open channel flow, differential level, or
Without module 0 volume conversion functions.
SmartLinx® Allen-Bradley® Remote I/O module 1 C) Subject to export regulations AL: N, ECCN: EAR99
SmartLinx PROFIBUS DP module
SmartLinx DeviceNetTM module
2
3 5
See SmartLinx product page 5/250 for more infor-
mation.
Approvals
General Purpose CE, FM, CSAUS/C, UL listed 1
CSA Class I, Div. 2, Groups A, B, C and D; Class II, 2
Div 2, Groups F and G; Class III (for wall mount
applications only)
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-5FC02
French C) 7ML1998-5FC11
German C) 7ML1998-5FC31
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
Selection and Ordering data Order No. Selection and Ordering data Order No.
Milltronics HydroRanger 200 C) 7 M L 1 0 3 4 - Milltronics HydroRanger 200 C) 7 M L 1 0 3 4 -
Ultrasonic level controller for up to six pumps that Ultrasonic level controller for up to six pumps that
77 7 77 77 7 77
provides control, differential control and open provides control, differential control and open
channel flow monitoring channel flow monitoring
Mounting Accessories
Wall mount, standard enclosure 1 Handheld programmer 7ML1830-2AK
Wall mount, 4 entries, 4 M20 cable glands included 2 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Panel mount1) 3 text line, suitable for enclosure
Power supply TS-3 Temperature Sensor - see TS-3 on page 5/144
100 to 230 V AC A
Spare parts
12 to 30 V DC B
Power Supply Board (100 to 230 V AC) C) 7ML1830-1MD
Communication (SmartLinx) Power Supply Board (12 to 30 V DC) C) 7ML1830-1ME
Without module A Display Board C) 7ML1830-1MF
SmartLinx® Allen-Bradley® Remote I/O module B
See SmartLinx product page 5/233 for more infor-
SmartLinx PROFIBUS DP module C mation.
TM
SmartLinx DeviceNet module D 1)
See SmartLinx product page 5/233 for more infor- Available with approval option 1 only.
mation. 2)
This model is level control only; no open channel flow, differential level, or
volume conversion functions.
Approvals
C) Subject to export regulations AL: N, ECCN: EAR99
5
General Purpose CE, FM, CSAUS/C, UL listed 1
CSA Class I, Div. 2, Groups A, B, C and D; Class II, 2 ®
Modbus is a registered trademark of Schneider Electric.
Div 2, Groups F and G; Class III (for wall mount ®
Belden is a registered trademark of Belden Wire and Cable Company.
applications only) ®
Allen-Bradley is a registered trademark of Rockwell Automation.
TMDeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA)
Number of measurement points
Single point model, 6 relays 1
Dual point model, 6 relays 2
Single point model, level only, 1 relay2) 3
Single point model, level only, 3 relays2) 4
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification
(max. 16 characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-1FC05
French C) 7ML1998-1FC14
German C) 7ML1998-1FC34
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
See note 1
DC version
DISCRETE
INPUTS
Selection and Ordering data Order No. Selection and Ordering data Order No.
MultiRanger 100/200 C) 7 M L 5 0 3 3 - MultiRanger 100/200 C) 7 M L 5 0 3 3 -
Versatile short to medium-range ultrasonic single Versatile short to medium-range ultrasonic single
7 7 7 77 - 77 77 7 77 - 77
and multi-vessel level monitor/controller for virtually and multi-vessel level monitor/controller for virtually
any application in a wide range of industries any application in a wide range of industries
Versions Instruction manual
MultiRanger 100, level measurement only 1 English C) 7ML1998-5FB05
MultiRanger 200, level, volume, flow and differential 2 French C) 7ML1998-5FB13
measurements Spanish C) 7ML1998-5FB23
Mounting, enclosure design German C) 7ML1998-5FB34
Wall mount, standard enclosure A Note: The instruction manual should be ordered as
Wall mount, 4 entries, 4 M20 cable glands included B a separate line on the order.
Panel mount (CE, CSAUS/C, FM, UL) C This device is shipped with the Siemens Milltronics
Power supply manual CD containing the complete ATEX Quick
100 to 230 V AC A Start and instruction manual library.
12 to 30 V DC B Other instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
Number of measurement points
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
Single point version 0
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
Dual point version 1
Communication (SmartLinx) SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12
See note 1
DC version
DISCRETE
INPUTS
MultiRanger connections
MultiRanger dimensions
■ Overview Accuracy
• Error in measurement 0.25% of range or 6 mm (0.24“),
whichever is greater
• Resolution 0.1% of measuring range1) or
2 mm (0.08“), whichever is
greater
• Temperature compensation -50 to +150 °C (-58 to +302 °F)
• Integral temperature sensor
• External TS-3 temperature sen-
sor (optional)
• Programmable fixed tempera-
ture
Rated operating conditions
Ambient conditions
• Ambient temperature for enclosure -20 to +50 °C (-4 to +122 °F)
Design
• Rack mount DIN 3 HU/14 pitch, 4 rail plug-in
unit suitable for standard 84 pitch
(19“) rack
HydroRanger Plus is an ultrasonic level controller for control of
• Outputs for alarms, chart recorders, controllers and integra- • Weight (rack and panel mount) 0.87 kg (1.9 lbs)
tion of existing systems • Weight (wall mount) 1.5 kg (3.3 lbs)
• Monitors wet wells, weirs and flumes • Material (enclosure) Polyester/polycarbonate alloy
• Energy-saving function with built-in real-time clock
• Special control mode to reduce grease rings and other depos- Electrical connection Commercially available copper
conductor according to local
its requirements, rated 250 V/5 A
• Integral temperature compensation
• Ultrasonic transducer cable exten- RG 62-A/U coaxial cable with low
• Pump performance monitoring sion capacitance
• System monitoring and network analysis
• mA output signal 2-core copper conductor, twisted,
■ Application
shielded, 0.5 to 0.75 mm² (22 to
18 AWG), Belden® 8760 or equiv-
alent is acceptable
The system is effective in wet wells, weirs and flumes where
foam and turbulence are typical operating conditions. It can be Power supply 100/115/200/230 V AC, ± 15%,
customized to meet your specific application needs – from mea- 50/60 Hz, 15 VA and/or
suring flow rate in a narrow flume to volume in a ferric chloride 9 to 30 V DC, 8 W
storage bank. • Ultrasonic transducer Compatible transducers: ST-H
The system consists of the electronics housed in a wall-mounted and Echomax series XPS-10/10F,
XPS 15/15F, XCT-8, XCT-12 and
enclosure and a hermetically sealed, corrosion-resistant XRS-5
Echomax® transducer. These components can be separated by
up to 365 m (1200 ft). Displays and controls
Optional submergence shields ensure consistent operation in Rack and panel mount 75 x 20 mm (3 x 0.8“) LCD
(selectable backlighting)
wet wells where the transducer may be submerged during flood-
ing from rainfall or a power outage. Siemens Milltronics patented Wall mount 100 x 40 mm (4 x 1.5“) multifield
detection software can differentiate between a submerged con- LCD, backlit
dition and a high level. Programming Removable programmer or
• Key Applications: wet wells, weirs, flumes optional Dolphin Plus
Memory EEPROM (non-volatile), no
■ Technical specifications backup battery required
Certificates and approvals CE2), FM, CSANRTL/C
Mode of operation
1) The measuring range corresponds to the distance from the zero point to
Measuring principle Ultrasonic level measurement
the sensor face, plus any range extension.
Measuring range 0.3 to 15 m (1 to 50 ft) 2) EMC certificate available on request
Measuring points 1 or 2 ®Belden is a registered trademark of Belden Wire and Cable Company.
Output
• Ultrasonic transducer 44 kHz
• Relays 5 alarm/control relays, 1 SPDT
Form C per relay, rated 5 A at
250 V AC, resistive load
• mA output 0/4 to 20 mA, optically isolated
- Max. load 1 kΩ
- Resolution 0.1% of 20 mA
Selection and Ordering data Order No. Selection and Ordering data Order No.
HydroRanger Plus, rack and panel mount C) 7 M L 1 0 2 5 - HydroRanger Plus, wall mount C) 7 M L 1 0 2 8 -
Non-contacting ultrasonic echo ranging technology 777 0 1 Non-contacting ultrasonic echo ranging technology 7A770
monitor that comes standard with a backlit display monitor that comes standard with a backlit display
Measuring range: 0.3 m to 15 m (1 to 50 ft) Measuring range: 0.3 m to 15 m (1 to 50 ft)
Mounting/device version Input voltage
Version for 19" rack (requires terminal block; see 1 100 V AC, 9 to 30 V DC 1
accessories) 115 V AC, 9 to 30 V DC 2
Version for panel 2
200 V AC, 9 to 30 V DC 3
Approvals 230 V AC, 9 to 30 V DC 4
CE (EN 61326), CSANRTL/C, FM C
Approvals
Input voltage CE; FM General Purpose; CSA Class I, Div. 2 C
100 V AC, 9 to 30 V DC A
Mounting/enclosure version
115 V AC, 9 to 30 V DC B
Standard enclosure (NEMA 4X) 1
200 V AC, 9 to 30 V DC C Standard enclosure prepared for five M20 cable 3
230 V AC, 9 to 30 V DC D glands
Further designs Order code Further designs Order code
Please add “-Z” to Order No. and specify Order Please add “-Z” to Order No. and specify Order
code(s). code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]:
Measuring-point number/identification (max. 16
Y15 Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]:
Measuring-point number/identification (max. 16
Y15
5
characters) specify in plain text characters) specify in plain text
Instruction manual Order No. Instruction manual Order No.
English C) 7ML1998-1AC02 English C) 7ML1998-1AC02
French C) 7ML1998-1AC12 French C) 7ML1998-1AC12
German C) 7ML1998-1AC32 German C) 7ML1998-1AC32
Note: The instruction manual should be ordered as Note: The instruction manual should be ordered as
a separate line item on the order. a separate line item on the order.
This device is shipped with the Siemens Milltronics This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick manual CD containing the complete ATEX Quick
Start and instruction manual library. Start and instruction manual library.
Accessories Accessories
Handheld programmer 7ML1830-2AC Handheld programmer 7ML1830-2AC
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
text line suitable for enclosures text line suitable for enclosures
Terminal block for rack mount 7ML1830-1JL M20 cable gland kit (6 M20 cable glands, 6 M20 7ML1830-1GM
TS-3 Temperature Sensor - see TS-3 on page 5/144 nuts, 3 stop plugs)
TS-3 Temperature Sensor - see TS-3 on page 5/144
Spare parts
Card, Analog HydroRanger Plus Rack/Panel C) 7ML1830-1LR Spare parts
Card, daughter C) 7ML1830-1LS Card, mother main C) 7ML1830-1LV
Card, display, backlit C) 7ML1830-1LX Card, daughter C) 7ML1830-1LW
Card, display C) 7ML1830-1LU
C) Subject to export regulations AL: N, ECCN: EAR99
C) Subject to export regulations AL: N, ECCN: EAR99
HydroRanger Plus dimensions HydroRanger Plus connections, rack and panel mount
■ Application
It combines non-contacting ultrasonic technology, patented
echo-processing techniques and proven application software to
provide accurate level monitoring in liquids up to 15 m (50 ft). It
also effectively monitors flow in flumes, weirs and open chan-
nels. Five relays control any combination of pumps, gate valves
and alarms. Further advantages include fault signalling and data
logging for trend analysis. It can log the time, date and volume
of up to 20 occurrences of combined sewer overflows (CSO).
The basic device has 8 digital inputs, 5 digital outputs, 1 analog
input, 1 ultrasonic level point, differential/average capability and
one RS-232 interface with Modbus® RTU/ASCII protocol. The
device can be expanded by additional I/Os, more RAM, two
channels, RS-485 or SmartLinx communications models as your
needs grow.
It integrates seamlessly with SCADA or DCS systems or a PLC
system to provide remote access to all system parameters
(pumped volume, pump runtime, pump status). The integral te-
lemetry interface (Modbus RTU/ASCII) allows remote control in
real time.
• Key Applications: wet well/lift station control, weirs/flumes,
open channels
5
2 analog input / 2 analog output for wall mount C) PBD-51034044
version
C)
8 digital input for rack and panel mount version PBD-51034042
8 digital input for wall mount version C) PBD-51034043
4 analog input for rack and panel mount version C) PBD-51034045
C)
4 analog input for wall mount version PBD-51034046
4 analog output for rack and panel mount version C) PBD-51034047
4 analog output for wall mount version C) PBD-51034048
8 digital inputs, 2 analog inputs, 2 analog outputs, C) PBD-51034272
wall mount
Access code, dual point capability C) 7ML1830-1KA
Auxiliary Cards2)
1 MB static RAM extended memory C) 7ML1830-1KR
2 analog input / 2 analog output for rack and C) 7ML1830-1KS
panel mount version
2 analog input / 2 analog output for wall mount C) 7ML1830-1KT
version
8 digital input for rack and panel mount version C) 7ML1830-1KU
8 digital input for wall mount version C) 7ML1830-1LA
4 analog input for rack and panel mount version C) 7ML1830-1LB
4 analog input for wall mount version C) 7ML1830-1LC
4 analog output for rack and panel mount version C) 7ML1830-1LD
4 analog output for wall mount version C) 7ML1830-1LE
8 digital inputs, 2 analog inputs, 2 analog outputs, C) 7ML1830-1LF
wall mount
1)
Values of parameters P345 and P346 must be obtained from the customer
in order to generate the order for the access code.
2) For replacement of auxiliary card or spare auxiliary card. Access code not
required. Must be used only as replacement cards.
■ Schematics
Notes
See Note 2 1. Transducer uses 2 wire twisted pair
AC Version with shield only.
2. Terminals 49-64 are for use with
optional expansion I/O cards.
DC Version
5
See Note 1
Wall Mount
27 43 -
!
1
28 44 +
AC Version 29 45 -
2 !
SL1 1 14 30 46 +
10 7
SL2 2 15 31 47
11 SL3 3 16 32 48 -
8
L2/N 12 SL4 4 17 33 49 +
SMARTLINX 18 DCD
SL5 5 34 50
L1 13
SL6 6 19 RXD 35 51 +
TS-3
SL7 7 20 TXD 36 52 -
SL8 8 21 DTR 37 53
10 RS232
SL9 9 22 SG 38 54
1
11 SYNC 10 23 DSR 39 55
6 2
11 24 RTS 40 56
12 5 3
12 25 CTS 41 57
4
13 13 26 24V 24V 42 58
■ Overview ■ Overview
The SITRANS LU01 is an ultrasonic long-range level controller The SITRANS LU02 is a dual point ultrasonic long-range level
■ Benefits ■ Benefits
• Single point, long-range level monitoring • Dual point, long-range level monitoring
• Easy to install and easy to program using removable infrared • Easy to install; easy to program using removable infrared key-
keypad (optional) pad (optional)
• Compatible with all Echomax® transducers • Compatible with all Echomax® transducers
• Backlit LCD display with reading in standard engineering units • Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom • Automatic level-to-volume conversion for standard or custom
tank shapes tank shapes
• Dolphin Plus and SmartLinx compatible • Dolphin Plus and SmartLinx compatible
• High/low alarms • High/low alarms
■ Application ■ Application
The system consists of a SITRANS LU01 monitor linked to a non- SITRANS LU02 will measure liquids, solids or a combination of
contacting ultrasonic transducer that can be mounted up to both in one or two vessels of different sizes, shapes and config-
365 m (1200 ft) away. The SITRANS LU01 will measure distance, urations up to 60 m (200 ft).
level or volume, and it features patented Sonic Intelligence®
echo processing software for superior reliability. The system uses ultrasonic technology to measure level, space,
distance, volume or average/differential. It features patented
Readings are displayed in user-selectable linear engineering Sonic Intelligence® echo processing software for superior reli-
units on the backlit LCD. ability. Transducers can be mounted up to 365 m (1200 ft) from
the monitor.
An on-board communications port automatically configures for
RS-232, RS-485 or bi-polar current loop. The SITRANS LU01 will Readings are displayed in user-selectable linear engineering
connect to a DCS or PLC using Siemens Milltronics SmartLinx® units on the backlit LCD.
interface modules, giving you remote 2-way communication and
full parameter access. Modules for popular industrial buses can It features an onboard communications port that automatically
be factory installed or added later to meet changing needs. No configures for RS-232, RS-485 or bi-polar current loop. It will
external gateway is required, reducing hardware and cabling connect to a DCS or PLC using Siemens Milltronics SmartLinx®
costs. interface modules, giving you remote 2-way communication and
full parameter access. Modules for popular industrial buses can
• Key Applications: chemical storage, liquid storage, bulk sol- be factory installed or added later to meet changing needs. No
ids storage (gravel, flour bins, grains, cereals), plastic pellets external gateway is required, reducing hardware and cabling
costs.
Key Applications: chemical storage, liquid storage, bulk solids
storage (gravel, flour bins, grains, cereals), plastic pellets, trip-
per car
5
- Outputs LU02 Max. two mA outputs
Accuracy
• Error in measurement 0.25% of range or 6 mm (0.24"),
whichever is greater
• Resolution 0.1% of measuring range or 2 mm
(0.8"), whichever is greater
• Temperature compensation -50 to +150 ºC (-58 to +302 ºF)
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LU01/LU02 C) 7 M L 5 0 0 4 - SITRANS LU01/LU02 C) 7 M L 5 0 0 4 -
Single or dual point ultrasonic long-range level 77 7 77 - 77 Single or dual point ultrasonic long-range level 7 7 7 77 - 77
monitoring system for liquids and solids, and monitoring system for liquids and solids, and
ranges up to 60 m (200 ft). ranges up to 60 m (200 ft).
Number of measuring points Instruction manual
LU01 version, 1 point 1 SITRANS LU02, English C) 7ML1998-5BD02
LU02 version, 2 points 2 SITRANS LU02, French C) 7ML1998-5BD12
■ Dimensional drawings
100 100
% %
209 mm 1 2 3 4
209 mm 1 2 3 4
(8.2”)
0 0
(8.2”)
11 22 33 44 11 22 33 44
55 66 77 88 55 66 77 88
mA
mA mA
mA
172 mm 99 00
PP PPX X X
172 mm 99 00
PP PPX X X
(6.8”) C
C %%
(6.8”) C
C %%
SITRANS LU 01 SITRANS LU 02
5
enclosure rating. (4 places) enclosure rating. (4 places)
Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right)
■ Schematics
5
SITRANS LU01 connections
5
uids and solids, offering 10-point monitoring in a single unit. • Error in measurement 0.25 % of range or 6 mm (0.24“),
whichever is greater
Hand Programmer shown is an accessory and must be ordered sepa-
• Resolution 0.1% of measuring range or 2 mm
rately.
(0.08“), whichever is greater
■ Application • Ambient temperature for enclosure -20 to +50 °C (-4 to +122 °F)
Design
It can be used in a wide range of applications to scan liquids,
solids or a combination of both contained in vessels of differing • Weight 2.7 kg (6 lbs)
size, shape and configuration up to 60 m (200 ft). • Material (enclosure) Polycarbonate
The SITRANS LU10 uses ultrasonic technology to measure level, • Degree of protection (wall mount) IP65/Type 4X/NEMA 4X
space, distance, volume or average/differential. Transducers
Electrical connection
can be mounted up to 365 m (1200 ft) from the monitor. The
SITRANS LU10 features patented Sonic Intelligence® echo pro- • Ultrasonic transducer RG62-A/U coaxial cable with low
cessing software for superior reliability. Readings are displayed capacitance
in user-selectable linear engineering units on the LCD. • Signal transmission 2-core copper conductor, twisted,
shielded, 0.5 to 0.75 mm² (22 to
SITRANS LU10 will connect to a DCS or PLC using Siemens 18 AWG), Belden® 8760 or equiv-
Milltronics SmartLinx® interface modules, giving you remote alent is acceptable
2-way communication and full parameter access. Modules for
popular industrial buses can be factory installed or added later • Electrical connection and relay Copper conductor according to
to meet changing needs. No external gateway is required, re- connection local requirements, rated 250 V
5A
ducing hardware and cabling costs.
• Key Applications: chemical storage, liquid storage, bulk sol- • Synchronization Up to 16 LU10 units can be syn-
chronized together
ids storage (sugar, flour bins, grains, cereals), plastic pellets,
tank farms Power supply 100/115/200/230 V AC ± 15%,
50/60 Hz, 15 VA
Displays and controls 51 x 127 mm (2 x 5") graphics
LCD with backlighting
• Memory EEPROM (non-volatile), no
backup battery required
• Programming Using removable programmer
(ordered separately) or Dolphin
Plus (option)
Certificates and approvals • CE, FM, CSANRTL/C , ATEX II 3D
• Lloyd’s Register of Shipping
(Categories ENV1, ENV2, ENV3
and ENV5)
CE, CSANRTL/C, FM A
ATEX II 3D B
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-5AN02
French C) 7ML1998-5AN12
German C) 7ML1998-5AN32
Note: The instruction manual should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other Instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12
SmartLinx Modbus, English C) 7ML1998-1BF01
SmartLinx Modbus, German C) 7ML1998-1BF31
Note: The appropriate SmartLinx instruction manual
should be ordered as a seperate line on the order.
Accessories
Handheld programmer 7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), 7ML1930-1AC
one text line, suitable for enclosures
Temperature Card (TIB-9) C) 7ML1830-1CN
M20 cable gland kit (6 M20 cable glands, 6 M20 7ML1830-1GM
nuts, 3 stop plugs)
TS-3 Temperature Sensor - see TS-3 on page 5/144
Spare parts
Card, mother main, comm ready C) 7ML1830-1ML
Card, daughter, comm ready C) 7ML1830-1LY
Card, display 7ML1830-1LQ
See SmartLinx product page 5/250 for more infor-
mation.
C) Subject to export regulations AL: N, ECCN: EAR99
®
Modbus is a registered trademark of Schneider Electric.
®
Allen-Bradley is a registered trademark of Rockwell Automation.
TM
DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA).
■ Dimensional drawings
106 mm
285 mm (4.2”)
267 mm (11.2") 92 mm
(10.5") (3.6”)
100
%
209 mm 1 2 3 4 5 6 7 8 9 10
0
(8.2") 11
0 0 0
2 3 4
172 mm 55
mA
mA
66 7 8
(6.8") 99 00
P PX X X
C %
SITRANS LU 10
■ Schematics 5
WHT/SHLD
WHT/SHLD
WHT/SHLD
WHT/SHLD
BLK
BLK
BLK
BLK
WHT/SHLD
WHT/SHLD
WHT/SHLD
BLK
BLK
WHT/SHLD
BLK
BLK
WHT/SHLD
BLK
Using a SITRANS LU SAM, you can have two relay outputs for all Power supply 100/115/200/230 V AC ± 15%,
50/60 Hz, 20 VA
ten measurement points, all 20 for a single measurement point
or any combination between the two. Displays and controls 1 LED for display of voltage/com-
munications state, 20 LEDs for
All relays are Form C to allow NO or NC wiring. display of relay states
Certificates and approvals CE, FM, CSANRTL/C
285 mm
(11.2”)
267 mm
SITRANS LU SAM (10.5”)
5
Ambient conditions
alog output for the measurement points of the SITRANS LU10
level monitor. • Ambient temperature for enclosure -20 to +50 °C (-5 to +122 °F)
• Location Indoor/outdoor
■ Benefits • Installation category II
• Analog outputs can be up to 1500 m (5000 ft) from the • Pollution degree 4
SITRANS LU10
Design
• Analog outputs can be per transducer and/or average of 2 or
more Weight 2 kg (4.4 lbs)
Material (enclosure) Polycarbonate
■ Application Degree of protection Type 4X/NEMA 4X/IP65
The operation of the SITRANS LU AO is programmed via the • Cable connection 2 copper conductors, twisted,
SITRANS LU10. The only on-board settings are for bank selec- with foil shield/drain wire, 300 V
tion and output testing. 0.5 to 0.75 mm² (22 to 18 AWG)
• Electrical connection and relay Copper conductor according to
The SITRANS LU AO can provide up to 10 analog outputs (each connection local requirements, rated 250 V
sharing a common negative bus which is electrically isolated 5A
from ground).
Power supply 100/115/200/230 V AC ± 15%,
50/60 Hz, 15 VA
Displays and controls 1 LED for display of voltage/com-
munications state
Certificates and approvals CE, FM, CSANRTL/C
■ Dimensional drawings
16 mm 209 mm
(0.6”) (8.2”)
172 mm lid screws 91 mm
(6.8”) (6 places) (3.6”)
285 mm
(11.2”)
267 mm
SITRANS LU AO (10.5”)
■ Schematics
SITRANS LU AO connections
■ Overview
Ultrasonic Transducers
Ultrasonic measuring systems are the cost-effective choice for
monitoring and control in short- to long-range applications for
liquids, slurries, and solids in a wide range of industries. Trans-
ducers are impervious to dust, moisture, corrosion, vibration,
flooding and extreme temperature. They are easy to install and
virtually maintenance free. Choose from a wide selection of mod-
els designed for short or long range applications on liquids or
solids.
■ Technical specifications
Echomax Transducers
Liquids Liquids and Solids Solids
Standard High Temperature High Temperature
XRS-5 ST-H XPS-10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12 XLT-30 XLT-60
Max. range 8m 10 m 10 m 15 m 30 m 40 m 8m 12 m 30 m 60 m
(26 ft) (33 ft) (33 ft) (50 ft) (100 ft) (130 ft) (26 ft) (40 ft) (100 ft) (200 ft)
5
When measuring chemicals, check compatibility of ETFE and epoxy, or
chemical storage and liquid tanks. mount joint external to process.
3)
EMC certificate available on request
■ Benefits Selection and Ordering data Order No.
• Can be mounted on a 2" (50.8 mm) standpipe Echomax® ST-H ultrasonic transducer C) 7 M L 1 1 0 0 -
• Immune to corrosive and harsh environments Level measurement in chemical storage and liquid 77A 7 0
• Integral temperature sensor tanks
The narrow design of the ST-H allows the trans-
■ Application ducer to be mounted on a 2” standpipe.
measuring range: min. 0.3 m (1 ft), max. 10 m
The narrow design of the ST-H allows the transducer to be (33 ft)
mounted on a 2" (50.8 mm) standpipe. When mounted correctly, Process connection
it is completely protected from the process and can even be 2" NPT [(Taper), ANSI/ASME B1.20.1] 0
used in harsh, corrosive environments. R 2" [(BSPT), EN 10226] 1
During operation, the ultrasonic transducer emits acoustic G 2” [(BSPP), EN ISO 228-1] 2
pulses in a narrow beam perpendicular to the transducer face. Cable length
The level transceiver measures the propagation time between 5 m (16.40 ft) A
pulse emission and reception of the echo to calculate the dis-
10 m (32.81 ft) B
tance from the transducer to the material. Variations in sound ve-
30 m (98.43 ft) C
locity due to changes in temperature within the permissible
range are automatically compensated by the integral tempera- 50 m (164.04 ft) D
ture sensor. 100 m (328.08 ft) E
• Key Applications: chemical storage, liquid tanks Approvals
FM Class I, Div. 1 [only with 2" NPT (Taper), 2
■ Technical specifications ANSI/ASME B1.20.1 process connection]
ATEX II 2G, CSA 3
Mode of operation
Instruction manual
Measuring principle Ultrasonic transducer Quick Start Manual, multi-language C) 7ML1998-5QK81
Input Applications Guidelines, multi-language C) 7ML1998-5HV61
■ Dimensional drawings
■ Schematics
5
Design
tinuous level monitoring of liquids and slurries in narrow lift sta-
tions/wet wells, flumes, weirs and filter beds using a beam angle Weight (approximate shipping 1.2 kg (2.6 lbs)
of just 10° and a CSM rubber face. weight of sensor with standard
cable length)
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XRS-5 transducer C) 7 M L 1 1 0 6 - Echomax® XRS-5 transducer C) 7 M L 1 1 0 6 -
With a beam angle of 10°, the XRS-5 provides reli- 777 7 0 - 0 7 With a beam angle of 10°, the XRS-5 provides reli- 777 7 0 - 0 7
able, continuous level monitoring of liquids and able, continuous level monitoring of liquids and
slurries in narrow lift stations/wet wells, flumes, slurries in narrow lift stations/wet wells, flumes,
weirs and filter beds. weirs and filter beds.
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft) Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft)
Process connection Accessories
1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
R 1" [(BSPT), EN 10226] 2 (0.47 x 1.77"), one text line for fastening on sensors
Cable length Submergence shield kit 7ML1830-1BH
5 m (16.40 ft) A Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
10 m (32.81 ft) B Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
30 m (98.43 ft) C and 1½" BSPT aluminum couplings
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
Facing
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
Standard (CSM rubber) A
1½" BSPT 304 SS couplings
PTFE (flange versions) B
FMS-200 universal box bracket, mounting kit 7ML1830-1BK
Approvals
FMS-210 channel bracket, wall mount 7ML1830-1BL
FM Class I, ATEX II 2G, CSA Class I Div. 2, SAA 2
FMS-220 extended channel bracket, wall mount 7ML1830-1BM
Class I
FMS-310 channel bracket, floor mount 7ML1830-1BN
Mounting flange (flush mount)
FMS-320 extended channel bracket, floor mount 7ML1830-1BP
5
None A FMS-350 bridge channel bracket, floor mount 7ML1830-1BQ
3" ASME, 150 lbs, flat faced B (See Mounting Brackets on page 5/143 for more
4" ASME, 150 lbs, flat faced C information.)
6" ASME, 150 lbs, flat faced D 1” NPT locknut, plastic 7ML1830-1DS
DN 80, PN 10/16, Type A, flat faced J 1" BSPT locknut, plastic 7ML1830-1DR
DN 100, PN 10/16, Type A, flat faced K
C) Subject to export regulations AL: N, ECCN: EAR99
DN 150, PN 10/16, Type A, flat faced L
JIS10K 3B style Q
JIS10K 4B style R
JIS10K 6B style S
Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
or EN 1092-1, or JIS B 2238 standard.
Instruction manual
Quick Start Manual, multi-language C) 7ML1998-5QT81
C) 7ML1998-5HV61
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
■ Overview
■ Benefits
• Integral temperature compensation
• Low ringing effect reduces blanking distance
• Optional foam facing for dusty applications
• Self-cleaning and low-maintenance
• Chemically resistant
• Hermetically sealed
■ Application
The transducers can be fully immersed, are resistant to steam
and corrosive chemicals and can be installed without flanges.
The XPS series offers versions for various measuring ranges up
to 40 m (130 ft) and up to a max. temperature of +95 °C
(+203 °F).
The XCT series can be used in applications at higher tempera-
tures to measure level up to a distance of 12 m (40 ft) and at a
max. temperature of +145 °C (+293 °F).
During operation, the Echomax transducers emit acoustic
pulses in a narrow beam. The level monitor measures the prop-
agation time between pulse emission and its reflection (echo) to
calculate the distance.
■ Technical specifications
Input XPS-10 (standard XPS-15 (standard XPS-30 XPS-40 XCT-8 (standard XCT-12
and F models) and F models) and sanitary mod-
els)
Measuring range 0.3 to 10 m Standard: 0.6 to 30 m 0.9 to 40 m 0.6 to 8 m 0.6 to 12 m
(1 to 33 ft) 0.3 to 15 m (2 to 100 ft) (3 to 130 ft) (2 to 26 ft) (2 to 40 ft)
(1 to 50 ft)
Flanged:
0.45 to 15 m
(1.5 to 50 ft)
Output
Frequency 44 kHz 44 kHz 30 kHz 22 kHz 44 kHz 44 kHz
Beam angle 12° 6° 6° 6° 12° 6°
Environmental
Location Indoors/outdoors
Ambient tempera- -40 to +95 °C (-40 to +203 °F) Standard: -40 to +145 °C
ture -40 to +145 °C (-40 to +293 °F)
(-40 to +293 °F)
Sanitary:
5
-40 to +125 °C
(-40 to +260 °F)
Pollution degree 4
Pressure 8 bar g (120 psi g) 8 bar g (120 psi g) 0.5 bar g 0.5 bar g Standard: 4 bar g (60 psi g):
Flanged: 0.5 bar g Flanged: 0.5 bar g (7.25 psi g) (7.25 psi g) -40 to +138 °C (-40 to +280 °F)
(7.25 psi g) (7.25 psi g) Flanged: 0.5 bar g Standard: 8 bar g (120 psi g):
(7.25 psi g) -40 to +95 °C (-40 to +203 °F)
Flanged: 0.5 bar g (7.25 psi g)
Sanitary: XCT-8: 0.5 bar g (7.25 psi g)
Design
Weight 0.8 kg 1.3 kg (2.8 lbs) 4.3 kg 8 kg 0.8 kg 1.3 kg
(1.8 lbs) Flanged: 2 kg (9.5 lbs) (18 lbs) (1.7 lbs) (2.8 lbs)
(4.4 lbs)
Power supply Operation of transducer only with approved Siemens Milltronics controllers
Material Standard: PVDF Standard: PVDF Standard: PVDF PVDF Standard: PVDF
Flanged: PVDF with Flanged: PVDF with Flanged: PVDF with Options: DERAKANE® flange; PTFE face
CPVC flange CPVC flange CPVC flange with universal PVDF flange
Option: PTFE face Option: PTFE face Option: PTFE face
with CPVC flange with CPVC flange with CPVC flange
Color Standard: blue Standard: blue blue blue white
F: gray F: gray
Process Standard: 1" NPT or Standard: 1" NPT or 1.5" universal thread (NPT or BSPT) 1" NPT or R 1" (BSPT), EN 10226
connection 1" BSPT 1" BSPT
F: 1" NPT F: 1" NPT
Cable 2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket 2 wire twisted pair/braided and foil
shielded 0.5 mm² (20 AWG) silicone
jacket
Separation Max. 365 m (1200 ft)
Certificates and Standard: Standard: CE1), CSA, FM, CE1), CSA, FM, Standard: CE1), CSA, FM,
approvals CE1), CSA, FM, CE1), CSA, FM, ATEX II 2G 1D ATEX II 2G 1D CE1), CSA, FM, ATEX II 2G
ATEX II 2GD ATEX II 2GD ATEX II 2G
F: FM Class I, Div 1, F: FM Class I, Div 1, Sanitary: CSA, 3A
Groups A, B, C and Groups A, B, C and
D, Class II Div 1, D, Class II Div 1,
Groups E, F and G, Groups E, F and G,
Class III Class III
1) EMC certificate available on request.
® DERAKANE is a registered trademark of Ashland Inc.
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-10 ultrasonic transducer C) 7 M L 1 1 1 5 - Echomax® XPS-10 ultrasonic transducer C) 7 M L 1 1 1 5 -
High-frequency ultrasonic transducer designed for 777 7 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Measuring range: min. 0.3 m, max.10 m Measuring range: min. 0.3 m, max.10 m
Mounting thread and facing Instruction Manual
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Quick Start guide, multi-language C) 7ML1998-5QM82
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam 1 Applications Guidelines, multi-language C) 7ML1998-5HV61
facing1) Note: The Applications Guidelines should be
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE 2 ordered as a separate line item on the order.
facing2) This device is shipped with the Siemens Milltronics
R 1" [(BSPT), EN 10226] 3 manual CD containing the complete ATEX Quick
R 1" [(BSPT), EN 10226] with foam facing1) 4 Start and instruction manual library.
R 1" [(BSPT), EN 10226] with PTFE facing2) 5 Accessories
Cable length Submergence shield kit 7ML1830-1BH
5 m (16.40 ft) B Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
10 m (32.81 ft) C
30 m (98.43 ft) E Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
5
50 m (164.04 ft) F Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
100 m (328.08 ft) K Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
Mounting flange 1½" BSPT 304 SS couplings
None A Universal box bracket, mounting kit 7ML1830-1BK
3" ASME, 150 lb, flat faced C Channel bracket, wall mount 7ML1830-1BL
4" ASME, 150 lb, flat faced D Extended channel bracket, wall mount 7ML1830-1BM
6" ASME, 150 lb, flat faced E Channel bracket, floor mount 7ML1830-1BN
8" ASME, 150 lb, flat faced F Extended channel bracket, floor mount 7ML1830-1BP
Bridge channel bracket, floor mount 7ML1830-1BQ
DN 80, PN 10/16, Type A, flat faced G (See Mounting Brackets on page 5/143 for more
DN 100, PN 10/16, Type A, flat faced J information.)
DN 150, PN 10/16, Type A, flat faced L
1” NPT locknut, plastic 7ML1830-1DS
JIS10K3B Style M 1" BSPT locknut, plastic 7ML1830-1DR
JIS10K4B Style P 1)
JIS10K6B Style R Not available with flanged versions
2)
(Note: Flange bolting patterns and facings dimen- Available with flanged versions only
sionally correspond to the applicable ASME B16.5 3)
Valid with mounting thread and facing options 0, 1 and 2 only
or EN 1092-1, or JIS B 2238 standard.)
C) Subject to export regulations AL: N, ECCN: EAR99
Approvals
ATEX II 2 GD, FM Class I Div. 2, SAA Class I 3
CSA Class I Div. 13) 4
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-15 ultrasonic transducer C) 7 M L 1 1 1 8 - Instruction manual
High-frequency ultrasonic transducer designed for 777 7 0 Quick Start Manual, multi-language C) 7ML1998-5QM82
a wide variety of liquid and solid applications, for Applications Guidelines, multi-language C) 7ML1998-5HV61
use with approved controllers. Includes integral Note: The Applications Guidelines should be
temperature sensor. ordered as a separate line item on the order.
Measuring range: min. 0.3 m, max. 15 m
This device is shipped with the Siemens Milltronics
Mounting thread and facing manual CD containing the complete ATEX Quick
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Start and instruction manual library.
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam 1 Accessories
facing1)
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE 2 Submergence shield kit 7ML1830-1BJ
facing2) Universal box bracket, mounting kit 7ML1830-1BK
Channel bracket, wall mount 7ML1830-1BL
R 1" [(BSPT), EN 10226] 3
R 1" [(BSPT), EN 10226] with foam facing1) 4 Extended channel bracket, wall mount 7ML1830-1BM
R 1" [(BSPT), EN 10226] with PTFE facing2) 5 Channel bracket, floor mount 7ML1830-1BN
Extended channel bracket, floor mount 7ML1830-1BP
Cable length
5 m (16.40 ft) B Bridge channel bracket, floor mount 7ML1830-1BQ
10 m (32.81 ft) C (See Mounting Brackets on page 5/143 for more
30 m (98.43 ft) E information.)
1” NPT locknut, plastic 7ML1830-1DS
50 m (164.04 ft) F 1" BSPT locknut, plastic 7ML1830-1DR
100 m (328.08 ft) K
5
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
Mounting flange Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
None A and 1½" BSPT aluminum couplings
6" ASME, 150 lb, flat faced D Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
8" ASME, 150 lb, flat faced E Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
DN 150, PN 10/16, Type A, flat faced J 1½" BSPT 304 SS couplings
DN 200, PN 10/16, Type A, flat faced K 1)
Not available with flanged versions
JIS10K 6B N 2)
Available with flanged versions only
JIS10K 8B P C) Subject to export regulations AL: N, ECCN: EAR99
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
or EN 1092-1, or JIS B 2238 standard.)
Approvals
ATEX II 2GD, FM Class I Div. 2, SAA Class I 3
CSA Class I Div. 1, available with mounting options 4
0, 1, 2 only
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-15F ultrasonic transducer C) 7 M L 1 1 7 1 - Echomax® XPS-30 ultrasonic transducer C) 7 M L 1 1 2 3 -
High-frequency ultrasonic transducer designed for 777 7 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Measuring range: min. 0.3 m, max. 15m 1½” universal thread compatible with 1½” NPT and
Mounting thread and facing R 1½” [(BSPT), EN 10226]
1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Measuring range: min. 0.6 m (1.97 ft), max. 30 m
(98.43 ft)
Cable length
Mounting thread and facing
5 m (16.40 ft) B
1½" universal thread 0
10 m (32.81 ft) C
1½" universal thread, foam facing1) 1
30 m (98.43 ft) D
1½" universal thread, PTFE facing2) 2
50 m (164.04 ft) E
Cable length
100 m (328.08 ft) F
5 m (16.40 ft) B
Mounting flange, flush mount 10 m (32.81 ft) C
None A 30 m (98.43 ft) E
6" ASME, 150 lb, flat faced B
50 m (164.04 ft) F
8" ASME, 150 lb, flat faced C
(Note: Flange bolting patterns and facings dimen- 100 m (328.08 ft) K
5
sionally correspond to the applicable ASME B16.5, Mounting flange
or EN 1092-1, or JIS B 2238 standard.) None A
Approvals 6" ASME, 150 lb, flat faced D
FM Class I Div. 1 1 8" ASME, 150 lb, flat faced E
Further designs Order code DN 150, PN 10/16, Type A, flat faced J
Please add “-Z” to Order No. and specify Order DN 200, PN 10/16, Type A, flat faced K
code(s).
JIS10K 6B N
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15 JIS10K 8B P
Measuring-point number/identification (max. 16 (Note: Flange bolting patterns and facings dimen-
characters); specify in plain text sionally correspond to the applicable ASME B16.5
Instruction manual Order No. or EN 1092-1, or JIS B 2238 standard.)
English C) 7ML1998-1DU01 Approvals
Note: The Instruction manual should be ordered as ATEX II 2G 1D, FM Class I Div 2, SAA 5
a separate line item on the order.
Applications Guidelines, multi-language C) 7ML1998-5HV61 Further designs Order code
Note: The Applications Guidelines should be Please add “-Z” to Order No. and specify Order
ordered as a separate line item on the order. code(s).
This device is shipped with the Siemens Milltronics Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
manual CD containing the complete ATEX Quick Measuring-point number/identification (max. 16
Start and instruction manual library. characters) specify in plain text
Accessories Instruction manual Order No.
Submergence shield kit 7ML1830-1BJ
Quick Start Manual, multi-language C) 7ML1998-5QM82
Universal box bracket, mounting kit 7ML1830-1BK
Applications Guidelines, multi-language C) 7ML1998-5HV61
Channel bracket, wall mount 7ML1830-1BL Note: The Applications Guidelines should be
Extended channel bracket, wall mount 7ML1830-1BM ordered as a separate line item on the order.
Channel bracket, floor mount 7ML1830-1BN This device is shipped with the Siemens Milltronics
Extended channel bracket, floor mount 7ML1830-1BP manual CD containing the complete ATEX Quick
Start and instruction manual library.
Bridge channel bracket, floor mount 7ML1830-1BQ
(See Mounting Brackets on page 5/143 for more Accessories
information.) 1½" BSPT locknut, plastic 7ML1830-1DP
1” NPT locknut, plastic 7ML1830-1DS Easy Aimer 2, 1½" NPT galvanized coupling 7ML1830-1AN
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ Easy Aimer 2, 1½" NPT with stainless steel coupling 7ML1830-1AT
Easy Aimer 304 with stainless steel coupling 7ML1830-1AU Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
1)
Not available with flanged versions
2)
Available with flanged versions only
C) Subject to export regulations AL: N, ECCN: EAR99
5 Approvals
ATEX II 2G 1D, FM Class I Div 2, SAA 5
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
Quick Start Manual, multi-language C) 7ML1998-5QM82
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
1½" BSPT locknut, plastic 7ML1830-1DP
Easy Aimer 2, 1½" NPT galvanized coupling 7ML1830-1AN
Easy Aimer 2, 1½" NPT with stainless steel coupling 7ML1830-1AT
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
C) Subject to export regulations AL: N, ECCN: EAR99
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XCT-8 ultrasonic transducer C) 7 M L 1 1 3 2 - Echomax® XCT-8 ultrasonic transducer C) 7 M L 1 1 3 2 -
High-frequency ultrasonic transducer designed for 777 7 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Ambient temperatures up to +145 °C (+293 °F) Ambient temperatures up to +145 °C (+293 °F)
Measuring range: min. 0.6 m (2 ft), max. 8 m (26 ft) Measuring range: min. 0.6 m (2 ft), max. 8 m (26 ft)
Mounting thread and facing Instruction manual
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Quick start manual, multi-language C) 7ML1998-5QM82
1" NPT [(Taper), ANSI/ASME B1.20.1], PTFE 1 XCT-8 with Sanitary Flange, multi-language C) 7ML1998-5HX61
facing1) Note: This manual should be ordered as a separate
R 1" [(BSPT), EN 10226] 2 line item with Mounting Option V.
Applications Guidelines, multi-language C) 7ML1998-5HV61
R 1" [(BSPT), EN 10226], PTFE facing1) 3 Note: The Applications Guidelines should be
Cable length ordered as a separate line item on the order.
1 m (3.28 ft) A This device is shipped with the Siemens Milltronics
5 m (16.40 ft) B manual CD containing the complete ATEX Quick
10 m (32.81 ft) C Start and instruction manual library.
30 m (98.43 ft) E Accessories
50 m (164.04 ft) F Submersible hood 7ML1830-1BH
Universal box bracket, mounting kit 7ML1830-1BK
5
100 m (328.08 ft) K
Channel bracket, wall mount 7ML1830-1BL
Mounting flange
None A Extended channel bracket, wall mount 7ML1830-1BM
Channel bracket, floor mount 7ML1830-1BN
3" ASME, 150 lb, flat faced C
Extended channel bracket, floor mount 7ML1830-1BP
4" ASME, 150 lb, flat faced D
6" ASME, 150 lb, flat faced E Bridge channel bracket, floor mount 7ML1830-1BQ
(See Mounting Brackets on page 5/143 for more
DN 80, PN 10/16, Type A, flat faced G information.)
DN 100, PN 10/16, Type A, flat faced J 1” NPT locknut, plastic 7ML1830-1DS
DN 150, PN 10/16, Type A, flat faced L 1" BSPT locknut, plastic 7ML1830-1DR
JIS10K 3B M Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
JIS10K 4B P Easy Aimer, aluminum, with M20 adapter and ¾ to 7ML1830-1AX
JIS10K 6B R 1” and 1½” BSPT couplings
(Note: Flange bolting patterns and facings dimen- Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
sionally correspond to the applicable ASME B16.5 1½" BSPT 304 SS couplings
or EN 1092-1 or JIS B 2238 standard.)
Sanitary, 4" mounting clamp 7ML1830-1BR
3" universal2) S Sanitary, isolating gasket C) 7ML1830-1KC
4" universal3) T
1)
6" universal4) U Available with flange versions S, T, U and V only
2)
Universal fits 3" ASME, DN80, JIS 10K3B style
4” sanitary flange, available with approval option 6 V
3)
and PTFE facing only Universal fits 4" ASME, DN100, JIS 10K4B style
4)
Approvals Universal fits 6" ASME, DN150, JIS 10K6B style
ATEX II 2G, FM Class I, Div. 2, SAA 4 C) Subject to export regulations AL: N, ECCN: EAR99
CSA Class I Div. 1, available with mounting thread 5
and facing option 0
3A Sanitary (only with 4” sanitary flange, option V) 6
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XCT-12 ultrasonic transducer C) 7 M L 1 1 3 6 - Echomax® XCT-12 ultrasonic transducer C) 7 M L 1 1 3 6 -
High-frequency ultrasonic transducer designed for High-frequency ultrasonic transducer designed for
777 7 0 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Ambient temperatures up to +145 °C (+293 °F) Ambient temperatures up to +145 °C (+293 °F)
Measuring range: min. 0.6 m (2 ft), max.12 m (40 ft) Measuring range: min. 0.6 m (2 ft), max.12 m (40 ft)
Mounting thread and facing Accessories
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Submergence shield kit 7ML1830-1BJ
1" NPT [(Taper), ANSI/ASME B1.20.1], PTFE facing, 1 Universal box bracket, mounting kit 7ML1830-1BK
available for flange options U only Channel bracket, wall mount 7ML1830-1BL
R 1" [(BSPT), EN 10226] 2 Extended channel bracket, wall mount 7ML1830-1BM
R 1" [(BSPT), EN 10226], PTFE facing, available for 3 Channel bracket, floor mount 7ML1830-1BN
flange options U only Extended channel bracket, floor mount 7ML1830-1BP
Cable length Bridge channel bracket, floor mount 7ML1830-1BQ
1 m (3.28 ft) A (See Mounting Brackets on page 5/143 for more
5 m (16.40 ft) B information.)
10 m (32.81 ft) C 1” NPT locknut, plastic 7ML1830-1DS
30 m (98.43 ft) E 1" BSPT locknut, plastic 7ML1830-1DR
50 m (164.04 ft) F Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
7ML1830-1GN
None A 1½" BSPT 304 SS couplings
6" ASME, 150 lb, flat faced D
C) Subject to export regulations AL: N, ECCN: EAR99
8" ASME, 150 lb, flat faced E
DN 150, PN 10/16, Type A, flat faced J
DN 200, PN 10/16, Type A, flat faced K
JIS10K 6B N
JIS10K 8B P
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
or EN 1092-1 or JIS B 2238 standard.)
6" universal for 6" ASME, DIN 150 or JIS 10K6B U
style
Approvals
ATEX II 2G, FM Class I, Div. 2, SAA 3
CSA Class I, Div. 1, available with mounting thread 4
and facing option 0 only
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
Quick Start Manual, multi-language C) 7ML1998-5QM82
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Version
Dimen. XCT-8 XCT-12
A 88 mm (3.464") 121 mm (4.764")
B 122 mm (4.803") 132 mm (5.197")
C According to ASME, DIN and JIS
E n/a n/a
F n/a n/a
G sanitary version: n/a
119 mm (4.68”)
H sanitary version: n/a
122 mm (4.8”)
J 28 mm (1.1") 28 mm (1.1")
■ Schematics
■ Application ■ Application
EA 304 aiming device EA 2 aiming device
The Easy Aimer 304 flange is a stainless steel aiming device for The Easy Aimer 2 flange is a cast aluminum aiming device for
alignment of Siemens Milltronics ultrasonic transducers used for alignment of Siemens Milltronics ultrasonic transducers.
level measurement of bulk solids.
The flange has graduated adjustments and an adjustable inser-
The sensor must be mounted aimed towards the low level draw tion length. When used for applications with bulk solids, the sen-
point in the silo. The sensor can be rotated through 360° and an- sor is mounted so that it is aimed towards the lower level draw
gled at 0 to 27° off vertical. It must be mounted using an access point in the silo. The sensor can be rotated through 360° and an-
plate with welded studs or a flange in order to isolate the mount- gled at 0 to 20° off vertical. It must be mounted using an access
ing holes from the pressurized environment. When installed plate with welded studs or a flange in order to isolate the mount-
properly, the EA 304 aiming device is capable of withstanding ing holes from the pressurized environment. When installed
pressures up to 0.5 bar (Europe) or 15 psi (North America). It properly, the EA 2 aiming device is capable of withstanding
can even be used in corrosive and aggressive environments. pressures up to 0.5 bar (Europe) or 15 psi (North America). It
can even be used in corrosive and aggressive environments.
1” NPT or BSP
coupling /
adapter
Siemens Milltronics
transducer (typical)
max. 27°
max 20°
178 mm
(7”)
ground screw
178 mm
(7.0”)
5 Instruction manual
Easy Aimer 2 and 304 Instruction manual,
Multi-language
7ML1998-5HG62
■ Application ■ Integration
Siemens Milltronics mounting brackets permit simple, fast instal-
lation of ultrasonic transducers. These rugged, high quality
mounting brackets are constructed of 304 (1.4301) stainless FMS-200
steel and are suitable for use indoors and outdoors. They adjust Universal Box Bracket
to fit almost any application, saving you the time and expense of
building custom brackets. Each kit includes all mounting parts.
FMS-200 universal box bracket system
Mounting of units with 1" or 2" threaded connection.
Distance from sensor to wall or beam: 20 to 31 cm (8 to 12").
The unique box design also acts as a sun shield for transducers
with 1" threaded connections.
FMS-210 wall mounting set
Mounting of transducers with 1" threaded connection. FMS-210
Channel Bracket,
Distance from transducer to wall or beam: 12 to 48 cm (5 to 19"). Wall Mount
FMS-220 extended wall mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to wall or beam: 32 to 98 cm (13 to 5
39").
FMS-310 floor mounting set
Mounting of transducers with 1" threaded connection. FMS-220
Extended Channel Bracket,
Distance from transducer to floor: 20 to 48 cm (8 to 19"). Wall Mount
Distance from mounting support: 5 to 57 cm (2 to 22").
FMS-320 extended floor mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to floor: 20 to 48 cm (8 to 19").
Distance from mounting support: 41 to 108 cm (16 to 43").
FMS-350 floor mounting set, bridge
FMS-310
Mounting of transducers with 1" threaded connection. Channel Bracket,
Floor Mount
Distance from transducer to floor: 20 to 48 cm (8 to 19"), any-
where along the complete width of the bridge [166 cm (65")].
This kit is particularly suitable for measurements on open chan-
nels (OCM) by providing a very stable mount for the transducer
above a flume or weir.
■ Overview ■ Design
Clearance
TS-3
The TS-3 temperature sensor provides an input signal for tem-
perature compensation of specific Siemens Milltronics ultrasonic
level controllers. plate or wall
■ Benefits
• Chemically resistant ETFE enclosure
Radar operation
■ Technical specifications
Radar Selection Guide
Criteria SITRANS SITRANS LR200 SITRANS LR250 SITRANS LR300 SITRANS LR400 SITRANS LR460
Probe LR
Typical industries Chemicals Chemicals, petro- Chemicals, Chemicals, petro- Cement, petro- Cement, power
chemicals petrochemicals chemicals chemicals generation, food
processing, min-
eral processing,
mining
Typical applications Liquids, storage Liquids, storage Liquids, storage Liquids, process Liquids storage Cement, flyash,
vessels and process ves- and process ves- vessels vessels, liquid grain, coal, flour,
sels sels with agitators, petroleum gas plastics
vaporous liquids, (LPG)
high temperatures,
low dielectric media
Range 0.3 to 20 m 0.3 to 20 m 50 mm (2”) from 0.4 to 20 m 0.35 to 50 m 100 m (328 ft)
(1 to 65 ft) (1 to 65 ft) end of horn to 20 m (1.3 to 65 ft) (1.14 to 164 ft)
(65 ft), horn depen-
dent
Frequency 5.8 GHz 5.8 GHz K-band (25.0 GHz) 5.8 GHz 24 to 25 GHz 24 to 25 GHz
(North America (North America (North America FMCW FMCW
5
6.3 GHz) 6.3 GHz) 6.3 GHz)
Performance 0.1% of range or 0.1% of range or 5 mm (0.02”) ± 15 mm (0.6”) from ≤ 5 mm (0.2”) from 0.25%
accuracy 10 mm (0.4”) 10 mm (0.4”) 0.4 to 10 m (1.3 to 2 to 10 m (6.6 to
32.8 ft) 32.8 ft)
± 0.15% from 10 to ≤ 15 mm (0.6”) from
20 m (1.3 to 65 ft) 10 to 50 m (32.8 to
164 ft)
Temperature Ambient: -40 to +80 Ambient: Ambient: Ambient: Ambient: Ambient: max.
°C (-40 to +176 °F) -40 to +80 °C -40 to +80 °C -40 to +60 °C -40 to +65 °C +65 °C (+149 °F)
Process: (-40 to +176 °F) (-40 to +176 °F) (-40 to +140 °F) (-40 to +149 °F) Process: max.
-40 to +80 °C Process: Process: Process: Process: +200 °C (+392 °F)
(-40 to +176 °F) -40 to +200 °C -40 to +150 °C -40 to +200 °C -40 to +250 °C
(-40 to +392 °F), (-40 to +302 °F) (-40 to +392 °F), (-40 to +482 °F),
dependent on dependent on dependent on dependent on
antenna type antenna type antenna type antenna type
Output/Communi- • 4 to 20 mA/HART® • 4 to 20 mA/HART • 4 to 20 mA/HART • 4 to 20 mA/HART • 4 to 20 mA/HART • 4 to 20 mA/HART
cations • SIMATIC PDM for • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA
remote configura- • SIMATIC PDM for • SIMATIC PDM for • Modbus • SIMATIC PDM for • SIMATIC PDM for
tion and diagnos- remote configura- remote configura- ASCII/RTU remote configura- remote configura-
tics tion and diagnos- tion and diagnos- tion and diagnos- tion and diagnos-
• SIMATIC PDM for
tics tics remote configura- tics tics
tion and diagnos-
tics
Power • 4 to 20 mA, • 4 to 20 mA loop, • 4 to 20 mA loop, • Universal AC/DC • 120 to 230 V AC, • 100 to 230 V AC,
24 V DC nominal, 24 V DC nominal, 24 V DC nominal, • 24 to 230 V AC, ±15%, 50/60 Hz ±15%, 50/60 Hz,
30 V DC max. 30 V DC max. 30 V DC max. ±15%, • 24 V DC, 6W
• Minimum voltage • Minimum voltage • Minimum voltage 40 to 70 Hz, +25/-20%, 6 W • 24 V DC,
depends on total depends on total depends on total 28 VA/11W (optional) +25/-20%, 6 W
loop resistance loop resistance loop resistance • 24 to 230 V DC,
± 15%, 9W
Approvals CE, CSAUS/C, FM, CE, CSAUS/C, FM, CSAUS/C, CE, FM CE, CSANRTL/C, FM, CE, CSAUS/C, FM, CSAUS/C, CE, FM
Lloyd’s Register of Lloyd’s Register of FCC, Industry Can- Lloyd’s Register of Lloyd’s Register of R&TTE, Industry
Shipping, ABS, Shipping, ABS, ada, R&TTE, ATEX, Shipping, ABS, Shipping, ABS, Canada, FCC,
FCC, Industry Can- FCC, Industry Can- PED, C-TICK FCC, Industry Can- FCC, Industry Can- ATEX, C-TICK
ada, R&TTE, ATEX, ada, R&TTE, ATEX, ada, R&TTE, ATEX, ada, R&TTE, ATEX,
PED PED 3A, PED PED
■ Overview ■ Configuration
5
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmit-
ter for continuous monitoring of liquids and slurries in storage
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).
■ Benefits
• Uni-Construction polypropylene rod antenna standard
• Easy installation and simple startup
• Programming using infrared Intrinsically Safe handheld pro-
grammer, SIMATIC PDM or HART® handheld communicator
• Communication using HART
• Patented Sonic Intelligence® signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of false echoes
■ Application
The Probe LR is ideal for applications with chemical vapours,
temperature gradients, vacuum or pressure, such as tank farms,
chemical storage, digesters and long-range applications.
SITRANS Probe LR has a range of 0.3 to 20 m (1 to 65 ft).
Probe LR is designed for safe and simple programming using
the Intrinsically Safe handheld programmer without having to
open the instrument’s lid. It has a standard Uni-Construction
polypropylene rod antenna that offers excellent chemical resis-
tance and is hermetically sealed. The Uni-Construction antenna
includes an internal, integrated shield that eliminates vessel noz-
zle interference. SITRANS Probe LR incorporates Sonic Intelli-
gence® signal processing. The Probe LR also has a high signal-
to-noise ratio leading to improved reliability.
Start-up is easy with as few as two parameters for basic opera-
tion. Programming is simple using SIMATIC PDM, HART® hand-
held communicator or the Intrinsically Safe handheld
programmer.
• Key Applications: tank farms, chemical storage
Accuracy ± the greater of 0.1% of range or • Approvals (handheld program- ATEX II 1G EEx ia IIC T4
10 mm (0.4") mer) CSA and FM Class I, Div.1,
Groups A,B,C,D, T6 @ max. ambi-
Influence of ambient temperature 0.003%/K ent
Repeatability ± 5 mm (2”) Display (local) Multi-segment alphanumeric liq-
Fail-safe mA signal programmable as high,
low or hold (LOE)
uid crystal with bar graph (repre-
senting level) available in four
languages
5
Rated operating conditions
• Installation conditions
- Location Indoor/outdoor
• Ambient conditions (enclosure)
- Ambient temperature -40 to +80 °C (-40 to +176 °F)
- Installation category I
- Pollution degree 4
Medium conditions
Dielectric constant εr εr > 1.6 (for εr < 3, use stillpipe)
Vessel temperature -40 to +80 °C (-40 to +176 °F)
Vessel pressure 3 bar g (43.5 psi g)
Design
• Enclosure
- Body construction PBT (Polybutylene Terephthalate)
- Lid construction PEI (Polyether Imide)
- Cable inlet 2 x M20x1.5 or 2 x ½" NPT with
adapter
• Degree of protection Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
• Weight 1.97 kg (4.35 lb)
• Antenna
- Material Polypropylene rod, hermetically
sealed construction
- Dimensions Standard 100 mm (4”) shield for
maximum 100 mm (4”) nozzle or
optional 250 mm (10”) long shield
• Process connections 1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
Power supply • Nominal 24 V DC with max.
550 Ω, maximum 30 V DC
• 4 to 20 mA
Certificates and approvals
General CSAUS/C, CE, FM
Marine • Lloyd’s Register of Shipping
• ABS Type Approval
Radio FCC, Industry Canada and Euro-
pean (R&TTE)
5
G 1½" [(BSPP), EN ISO 228-1], c/w integral F
250 mm shield
Approvals
General Purpose, CE1) A
General Purpose, FM, CSAUS/C2) B
CSA Class I, Div 1, Groups A, B, C, D, Class II, Div. C
1 Group G, Class III, Intrinsically Safe with suitable
barrier2)
FM, Class I, II and III, Div 1, Groups A, B, C, D, E, F, D
G, Intrinsically Safe with suitable barrier2)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with suit- E
able barrier1)
Communication/Output
4 to 20 mA, HART® 1
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Test certificate: Manufacturer's test certificate M to C11
DIN 55350, Part 18 and to ISO 9000
Instruction manual Order No.
English C) 7ML1998-5HR02
French C) 7ML1998-5HR11
Spanish C) 7ML1998-5HR21
German C) 7ML1998-5HR31
Note: The instruction manual should be ordered as
a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Additional quick start manual
Multi-language Quick Start manual C) 7ML1998-5QP81
Note: Due to ATEX regulations, one Quick Start
manual is included with every product.
Optional equipment
Handheld programmer, Intrinsically Safe, 7ML5830-2AH
ATEX II 1G, EEx ia
HART® modem/RS-232 (for use with a PC and D) 7MF4997-1DA
SIMATIC PDM)
HART modem/USB (for use with a PC and D) 7MF4997-1DB
SIMATIC PDM)
One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 to +80 °C (-40 to +176 °F)
Spare parts
Plastic lid C) 7ML1830-1KB
1)
Includes European Radio approvals (R&TTE), 5.8 GHz
2)
Includes FCC Radio approvals, 6.3 GHz for North America only
■ Dimensional drawings
■ Schematics
■ Overview
■ Benefits
• Uni-Construction polypropylene rod antenna standard, other
antenna options available
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld pro-
grammer or SIMATIC PDM
• Communication using HART® or PROFIBUS PA
• Patented Sonic Intelligence® signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of fixed obstructions
• Various flanges, horn and waveguide antenna options avail-
able
■ Application
SITRANS LR200’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. It also features a
built-in alphanumeric display in four languages.
The SITRANS LR200 has a standard Uni-Construction polypro-
pylene rod antenna that offers excellent chemical resistance and
is hermetically sealed. With other instruments, you may need to
consider compatibility of multiple materials including the seal
between the materials. The Uni-Construction antenna features
an internal, integrated shield that eliminates vessel nozzle inter-
ference.
Start-up is easy with as few as two parameters for basic opera-
tion. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up
with conduit or wiring connections or simply to adjust the posi-
tion for easy viewing. SITRANS LR200 features patented Sonic
Intelligence signal-processing technology for superior
reliability.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, asphalt,
digesters
■ Configuration
Installation Mounting unit on bypass Mounting unit on stilling well
min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall. Orient front or
back of device
toward vent.
optimum Orient front or
diameter back of device
80 mm (3”) toward stillpipe
slots.
beam
angle
20°
5
Mounting unit on vessel Mounting on a manhole cover Mounting on a nozzle
Fl at
Coni
Flat
Conical
Parabolic
minimum 10 mm (0.4”)
minimum
100 mm (4”)
• Span Proportional or inversely propor- - General Purpose, Non-incen- Nominal 24 V DC (max. 30 V DC)
tional dive, Intrinsically Safe with max. 550 Ω
5
• Blanking distance 0.3 m (from reference point plus
any shield length) • ABS Type Approval
• Accuracy ± the greater of 0.1% of range or • Radio FCC, Industry Canada and
10 mm European (R&TTE)
Rated operating conditions - Increased safety (Europe) ATEX II 1/2 G EEx em ia IIC T4
Installation conditions - Explosion proof (USA/Canada) FM/CSA (barrier not required) T4,
Class I, Div. 1, Groups A, B, C, D;
• Location Indoor/outdoor Class II, Div. 1, Groups E, F, G;
Class III
Ambient conditions (enclosure)
- Non-incendive (USA) FM (barrier not required) T5,
• Ambient temperature -40 to +80 °C (-40 to +176 °F) Class I, Div. 2, Groups A, B, C, D
• Installation category I - Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T4
• Pollution degree 4 - Intrinsically Safe (USA/Canada) FM/CSA (barrier required) T4,
Medium conditions Class I, Div. 1, Groups A, B, C, D;
Class II, Div. 1, Groups E, F, G;
• Dielectric constant εr εr > 1.6 (for εr < 3, use Class III
waveguide antenna or stillpipe)
- Intrinsically Safe (Australia) ANZEX Ex ia IIC T4
• Vessel temperature and pressure Varies with connection type; see (Tamb = -40 to +80 °C) IP67
Pressure/Temperature curves for
more information - Intrinsically Safe (International) IECEX TSA 04.0020X T4
Design Programming
• Enclosure • Intrinsically Safe Siemens Milltron- Infrared receiver
ics handheld programmer
- Material Aluminium, polyester powder
coated - Approvals for handheld pro- IS model with ATEX EEx ia IIC T4,
grammer FM/CSA Class I, Div. 1, Groups A,
- Cable inlet 2 x M20x1.5 or 2 x ½" NPT with B, C, D
adapter
• Handheld communicator HART
• Degree of protection Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68 • PC SIMATIC PDM
• Weight < 2 kg (4.4 lbs) (polypropylene • Display (local) Multi-segment alphanumeric liq-
rod antenna) uid crystal with bar graph (repre-
senting level) available in four
• Display (local) Multi-segment alphanumeric liq- languages
uid crystal with bar graph (repre-
senting level) available in four HART® is a registered trademark of the Hart Communications Foundation.
languages
• Antenna
- Material Polypropylene rod, hermetically
sealed construction, optional
PTFE
- Dimensions Standard 100 mm (4”) shield for
maximum 100 mm (4”) nozzle, or
optional 250 mm (10”) long shield
- Optional rods, horn and Refer to SITRANS LR200/LR300
waveguides Antennas for optional rods, horns
and waveguides
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Uni-Construction C) 7 M L 5 4 2 2 - SITRANS LR200, Uni-Construction C) 7 M L 5 4 2 2 -
polypropylene rod antenna version polypropylene rod antenna version
777 7 0 7777 0
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
[Max. +80 °C (+176 °F), 3 bar] [Max. +80 °C (+176 °F), 3 bar]
Enclosure/Cable inlet Instruction manual for HART/mA device
Aluminum, Epoxy painted English C) 7ML1998-5FN04
2 x ½" NPT 0 French C) 7ML1998-5FN11
2 x M20x1.5 1 German C) 7ML1998-5FN34
Note: The instruction manual should be ordered
Polypropylene antenna type - (Max. 3 Bar pres- as a separate line item on the order.
sure and +80 °C)
1½" NPT [(Taper), ANSI/ASME B1.20.1], A Multi-language Quick Start manual C) 7ML1998-5QL83
c/w integral 100 mm shield This device is shipped with the Siemens Milltronics
R 1½" [(BSPT), EN 10226], B manual CD containing the complete ATEX Quick
c/w integral 100 mm shield Start and instruction manual library.
G 1½" [(BSPP), EN ISO 228-1], C
c/w integral 100 mm shield Instruction manual for PROFIBUS device
English C) 7ML1998-5HP01
1½" NPT [(Taper), ANSI/ASME B1.20.1], D French C) 7ML1998-5HP11
5
c/w integral 250 mm shield
German C) 7ML1998-5HP31
R 1½" [(BSPT), EN 10226], E Note: The instruction manual should be ordered
c/w integral 250 mm shield as a separate line item on the order.
G 1½" [(BSPP), EN ISO 228-1], F
c/w integral 250 mm shield Multi-language Quick Start manual C) 7ML1998-5QG81
Approvals This device is shipped with the Siemens Milltronics
General Purpose, CE1) A manual CD containing the complete ATEX Quick
Start and instruction manual library.
General Purpose, CSAUS/C, FM, for North America B
only2) Accessories
CSA Class I and II, Div. I, Groups A, B, C, D, G, C Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH
6.3 GHz, for North America only, Intrinsically Safe (for HART device)
with suitable barrier2) Handheld programmer, Intrinsically Safe, EEx ia C) 7ML5830-2AJ
FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D (for PROFIBUS PA device)
for North America only, Intrinsically Safe with suit- HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
able barrier2) SIMATIC PDM)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E HART modem/USB (for use with a PC and D) 7MF4997-1DB
suitable barrier1) SIMATIC PDM)
FM, Class I, Div. 2, Groups A, B, C, D, for North F One metallic cable gland M20x1.5, 7ML1930-1AP
America only (no barrier required)2) and 4) rated -40 °C to +80 °C (-40 to +176 °F) for General
ATEX II 1/2 G EEx em ia IIC T4 (no barrier G Purpose or ATEX EEx e installations (available for
required)1), 3) and 5) HART only)
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H One metallic cable gland M20x1.5, rated -40 °C 7ML1930-1AQ
required)1) and 5) (-40 °F) to +80 °C (+176 °F) with integrated shield
connection (available for PROFIBUS PA)
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, J
E, F, G (no barrier required)2), 4) and 5) 1)
Includes European Radio approval (R&TTE), 5.8 GHz
2)
Communication/Output Includes Radio approval FCC, 6.3 GHz
4 to 20 mA, HART® 1 3)
Available with enclosure option 1 only
PROFIBUS PA 2 4)
Available with enclosure option 0 only
5)
Further designs Order code Available with communication option 1 only
Please add “-Z” to Order No. and specify Order C) Subject to export regulations AL: N, ECCN: EAR99
code(s). D) Subject to export regulations AL: N, ECCN: EAR99H
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Test certificate: Manufacturer's test certificate M to C11
DIN 55350, Part 18 and to ISO 9000
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter, Sanitary C) 7 M L 5 4 2 4 - SITRANS LR200, Flange Adapter, Sanitary C) 7 M L 5 4 2 4 -
Version Version
77 7 77 - 77 77 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft) and pressure, to a range of 20 m (66 ft)
Antenna material (uses antenna adapter) Instruction manual for HART/mA device
PTFE, one piece rod antenna 0 English C) 7ML1998-5FN04
UHMW-PE, one piece rod antenna 1 French C) 7ML1998-5FN11
Communication/Output Accessories
4 to 20 mA, HART® A Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH
(for HART device)
PROFIBUS PA B
Handheld programmer, Intrinsically Safe, EEx ia C) 7ML5830-2AJ
Approvals (for PROFIBUS PA device)
General Purpose, CE1) A HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
General Purpose, CSAUS/C, FM, for North America B SIMATIC PDM)
only HART modem/USB (for use with a PC and D) 7MF4997-1DB
CSA Class I and II, Div. I, Groups A, B, C, D, G, for C SIMATIC PDM)
North America only, Intrinsically Safe with suitable One metallic cable gland M20x1.5, 7ML1930-1AP
barrier rated -40 °C to +80 °C (-40 to +176 °F) for General
FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D Purpose or ATEX EEx e installations (available for
for North America only, Intrinsically Safe with suit- HART only)
able barrier One metallic cable gland M20x1.5, 7ML1930-1AQ
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E rated -40 °C to +80 °C (-40 to +176 °F) with inte-
suitable barrier1) grated shield connection (available for PROFIBUS
FM, Class I, Div. 2, Groups A, B, C, D, FCC F PA)
6.3 GHz, for North America only (no barrier Sanitary fitting clamps
required) 2) and 4) 2", 304 stainless steel 7ML1830-1HD
ATEX II 1/2 G EEx em ia IIC T4 (no barrier G 3", 304 stainless steel 7ML1830-1HE
required)1), 3) and 5) 4", 304 stainless steel 7ML1830-1HF
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H 1)
required)1) and 5) Includes European Radio approval (R&TTE), 5.8 GHz
2)
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, J Includes Radio approval FCC, 6.3 GHz
E, F, G (no barrier required)2), 4) and 5) 3)
Available with enclosure option 1 only
4)
Pressure rating Available with enclosure option 0 only
Rating per Pressure/Temperature curves in Manual 0 5)
Available with communication option A only
0.5 bar (7.25 psi) maximum 1 C) Subject to export regulations AL: N, ECCN: EAR99
Further designs Order code D) Subject to export regulations AL: N, ECCN: EAR99H
Please add “-Z” to Order No. and specify Order
code(s).
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter/PTFE Rod C) 7 M L 5 4 2 3 - SITRANS LR200, Flange Adapter/PTFE Rod C) 7ML 5 4 2 3 -
Antenna Version 77 7 77 - 77 77 Antenna Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft) and pressure, to a range of 20 m (66 ft)
Antenna material (uses antenna adapter) Approvals
PTFE, uses antenna adapter and additional pro- 1 General Purpose, CE1) A
cess connection below General Purpose, CSAUS/C, FM, for North America B
Process connection (refer to Pressure/Tempera- only2)
ture curves in Instruction manual) CSA Class I and II, Div. I, Groups A, B, C, D, G, for C
Flat Faced Flanges (316L stainless steel) North America only, Intrinsically Safe with suitable
DN 50 PN 16, Type A, flat faced AA barrier2)
DN 80 PN 16, Type A, flat faced BA FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D
DN 100 PN 16, Type A, flat faced CA for North America only, Intrinsically Safe with suit-
DN 150 PN 16, Type A, flat faced DA able barrier2)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E
2" ASME 150 lb, flat faced FB suitable barrier1)
3" ASME 150 lb, flat faced GB FM, Class I, Div. 2, Groups A, B, C, D, FCC F
4" ASME 150 lb, flat faced HB 6.3 GHz, for North America only (no barrier
6" ASME 150 lb, flat faced JB required) 2) and 4)
DN 50 PN 40, flat faced AC ATEX II 1/2 G EEx em ia IIC T4 (no barrier G
5
DN 80 PN 40, flat faced BC required)1), 3) and 5)
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H
DN 100 PN 40, flat faced CC
required)1) and 5)
DN 150 PN 40, flat faced DC
CSA/FM Class I, II and III, Div. 1, Groups A,B, C, D, J
2" ASME 300 lb, flat faced, available with FD E, F, G (no barrier required)2), 4) and 5)
Pressure Rating option 1 only
Pressure rating
3" ASME 300 lb, flat faced GD
rating per Pressure/Temperature curves in Manual 0
4" ASME 300 lb, flat faced HD 0.5 bar (7.25 psi) maximum 1
6" ASME 300 lb, flat faced JD
Further designs Order code
JIS DN50 10K AE
Please add “-Z” to Order No. and specify Order
JIS DN80 10K BE
code(s).
JIS DN100 10K CE
Acceptance test certificate: Manufacturer's test C11
JIS DN150 10K DE
certificate M to DIN 55350, Part 18 and to ISO 9000
(Note: Flange bolting patterns and facings dimen-
Inspection Certificate Type 3.1 per EN 10204 C12
sionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2238 standard.) Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
Threaded connection (316L stainless steel)
characters); specify in plain text
1-½" NPT [(Taper), ANSI/ASME B1.20.1] LA
Inactive custom shield lengths: Enter the total Y01
2" NPT [(Taper), ANSI/ASME B1.20.1] MA
length of the inactive shield in plain text description
R 1-½" [(BSPT), EN 10226] LC
(in 1 mm increments).
R 2" [(BSPT), EN 10226] MC
Instruction manual for HART/mA device Order No.
G 1-½" [(BSPP), EN ISO 228-1] LE
English C) 7ML1998-5FN04
G 2" [(BSPP), EN ISO 228-1] ME
French C) 7ML1998-5FN11
Antenna extensions or Inactive shield length German C) 7ML1998-5FN34
No antenna extension 0 Note: The instruction manual should be ordered
50 mm (2”) extension, PTFE 1 as a separate line item on the order.
100 mm (4”) extension, PTFE 2
Multi-language Quick Start manual C) 7ML1998-5QL83
100 mm (4”) extension, 316L stainless steel shield6) 3
This device is shipped with the Siemens Milltronics
150 mm (6”) extension, 316L stainless steel shield6) 4
manual CD containing the complete ATEX Quick
200 mm (8”) extension, 316L stainless steel shield6) 5
Start and instruction manual library.
250 mm (10”) extension, 316L stainless steel 6
Instruction manual for PROFIBUS device
shield6)
English C) 7ML1998-5HP01
Custom inactive shield length 101 mm to 1000 mm 7 French C) 7ML1998-5HP11
(in 1 mm increments) Add order code Y01 and German C) 7ML1998-5HP31
6)
plain text: “Inactive shield length...mm” Note: The instruction manual should be ordered
Process Seal/Gasket as a separate line item on the order.
Integral Gasket, for flat faced flange process con- 0 Multi-language Quick Start manual C) 7ML1998-5QG81
nections only, not for Antenna extension options 3
This device is shipped with the Siemens Milltronics
to 6
manual CD containing the complete ATEX Quick
FKM O-ring, not available for combination of flat 1
Start and instruction manual library.
faced flanges with Antenna extension options 0, 1
or 2
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT 0
2 x M20x1.5 1
Communication/Output
4 to 20 mA, HART® A
PROFIBUS PA B
PROFIBUS PA)
1)
Includes European Radio approval (R&TTE), 5.8 GHz
2)
Includes Radio approval FCC, 6.3 GHz
3)
Available with enclosure option 1 only
4)
Available with enclosure option 0 only
5)
Available with communication option A only
6)
Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter/Horn Antenna C) 7ML 5 4 2 5 - SITRANS LR200, Flange Adapter/Horn Antenna C) 7 M L 5 4 2 5 -
Version 77 7 77 - 77 77 Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft) and pressure, to a range of 20 m (66 ft)
Antenna Material (uses antenna adapter) 150 mm (6”) horn with 250 mm (10”) waveguide N
316L stainless steel with PTFE cone emitter 0 extension
316L stainless steel with PTFE cone emitter and 1 200 mm (8”) horn with 100 mm (4”) waveguide P
purge connection with 1/8” NPT inlet7) extension
Sliding waveguide system with 1000 mm (40”) 2 200 mm (8”) horn with 150 mm (6”) waveguide Q
waveguide7) extension
Process connection (refer to Pressure/Tempera- 200 mm (8”) horn with 200 mm (8”) waveguide R
ture curves on specification sheets) extension
Flat Faced Flanges (316L stainless steel) 200 mm (8”) horn with 250 mm (10”) waveguide S
DN 50 PN 16, Type A, flat faced7) AA extension
DN 80 PN 16, Type A, flat faced BA Waveguide only - Waveguide length 500 mm to T
DN 100 PN 16, Type A, flat faced CA 3000 mm (in 1 mm increments) (Add order code
DN 150 PN 16, Type A, flat faced DA Y01 and plain text: “waveguide length ...mm”)
DN 200 PN 16, Type A, flat faced EA Horn with custom waveguide lengths 101 to U
2000 mm (Add order codes Y01 and Y03 and plain
2" ASME 150 lb, flat faced7) FB
text: “waveguide length...mm”,
5
3" ASME 150 lb, flat faced GB and “horn size ...mm”)8)
4" ASME 150 lb, flat faced HB Approvals
6" ASME 150 lb , flat faced JB General Purpose, CE1) A
8" ASME 150 lb, flat faced KB General Purpose, CSAUS/C, FM, for North America B
DN 50 PN 40, flat faced7) AC only2)
DN 80 PN 40, flat faced BC CSA Class I and II, Div. I, Groups A, B, C, D, G, for C
DN 100 PN 40, flat faced CC North America only, Intrinsically Safe with suitable
DN 150 PN 40, flat faced DC barrier2)
DN 200 PN 40, flat faced EC FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D
2" ASME 300 lb, flat faced7) FD for North America only, Intrinsically Safe with suit-
able barrier2)
3" ASME 300 lb, flat faced GD
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E
4" ASME 300 lb, flat faced HD suitable barrier1)
6" ASME 300 lb, flat faced JD FM, Class I, Div. 2, Groups A, B, C, D, for North F
8" ASME 300 lb, flat faced KD America only (no barrier required)2)
JIS DN 50 10K7) AE ATEX II 1/2 G EEx em ia IIC T4 (no barrier G
JIS DN 80 10K BE required)1), 4) and 6)
JIS DN 100 10K CE ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H
JIS DN 150 10K DE required)1) and 6)
JIS DN 200 10K EE CSA/FM Class I, II and III, Div. 1, Groups A B, C, D, J
(Note: Flange bolting patterns and facings dimen- E, F, G (no barrier required)2), 5) and 6)
sionally correspond to the applicable ASME B16.5, Pressure rating
or EN 1092-1, or JIS B 2238 standard.) Rating per Pressure/Temperature curves in Manual 0
Communication/Output 0.5 bar (7.25 psi) maximum 1
4 to 20 mA, HART® 0 Further designs Order code
PROFIBUS PA 1
Please add “-Z” to Order No. and specify Order
Process Seal/Gasket code(s).
FKM (-40 to +200 °C) 0
Acceptance test certificate: Manufacturer's test C11
Nitrile (-40 to +100 °C), sliding waveguide sytems 1 certificate M to DIN 55350, Part 18 and to ISO 9000
only
Inspection Certificate Type 3.1 per EN 10204 C12
FFKM (-35 to +200 °C) 2
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Enclosure/Cable inlet
Aluminum, Epoxy painted Measuring-point number/identification (max. 16
2 x ½" NPT 0 characters) specify in plain text
2 x M20x1.5 1 Waveguide custom lengths: Enter the total length of Y01
Horn size/Waveguide options the waveguide in plain text description (1 mm
80 mm (3”) horn3) B increments)
100 mm (4”) horn3) C Enter the waveguide length (100 mm to 1000 mm) Y03
150 (6”) mm horn D and enter the horn size (100 mm, 150 mm, and
200 (8”) mm horn E 200 mm only) in plain text description
100 mm (4”) horn with 100 mm (4”) waveguide F Instruction manual for HART/mA device Order No.
extension3) English C) 7ML1998-5FN04
100 mm (4”) horn with 150 mm (6”) waveguide G French C) 7ML1998-5FN11
extension3) German C) 7ML1998-5FN34
100 mm (4”) horn with 200 mm (8”) waveguide H Note: The instruction manual should be ordered
extension3) as a separate line item on the order.
100 mm (4”) horn with 250 mm (10”) waveguide J Multi-language Quick Start manual C) 7ML1998-5QL83
extension3) This device is shipped with the Siemens Milltronics
150 mm (6”) horn with 100 mm (4”) waveguide K manual CD containing the complete ATEX Quick
extension Start and instruction manual library.
150 mm (6”) horn with 150 mm (6”) waveguide L
extension
150 mm (6”) horn with 200 mm (8”) waveguide M
extension
D)
7MF4997-1DA
7MF4997-1DB
SIMATIC PDM®)
One metallic cable gland M20x1.5, rated -40 °C to 7ML1930-1AP
+80 °C (-40 to +176 °F) (available for HART only)
One metallic cable gland M20x1.5, rated -40 °C to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
nection (available for PROFIBUS PA)
1)
Includes European Radio approval (R&TTE), 5.8 GHz
2)
Includes Radio approval FCC, 6.3 GHz
3)
For stillpipe applications only
4)
Available with enclosure option 1 only
5)
Available with enclosure option 0 only
6)
Available with communication option 0 only
7)
Available with pressure rating option 1 only
8)
Order standard waveguide lengths 100, 150, 200, 250 mm (3.93, 5.91,
7.87, 9.84”) by choosing options from Horn size/Waveguide options
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H
■ Characteristic curves
■ Dimensional drawings
■ Schematics
■ Overview ■ Configuration
Installation
beam width:
1.5” horn = 19°
2” horn = 15°
3” horn = 10°
19° 4” horn = 8°
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter Mounting unit on bypass
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).
Orient
front or
5
back of
device
■ Benefits toward
vent.
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support Use largest
• 25 GHz high frequency allows for small horn antennas for easy horn size
mounting in nozzles possible
in pipe.
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference Mounting unit on stilling well
• Short blanking distance for improved minimum measuring
range to 50 mm from the end of the horn Orient front or
back of device
• Communication using HART® or PROFIBUS PA toward stillpipe
• Process Intelligence signal processing for improved measure- slots.
ment reliability and Auto False-Echo Suppression of fixed ob-
structions Use
• Programming using infrared Intrinsically Safe handheld pro- largest
grammer or SIMATIC PDM horn size
possible
Mounting unit on vessel
in pipe.
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Startup is easy using the Quick Start wizard with a few pa-
rameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller horn options and decreasing sensitivity to obstruc-
tions.
SITRANS LR250’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. Mounting on a nozzle
SITRANS LR250 measures superbly on low dielectric media,
and in small vessels, as well as tall and narrow vessels.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, low di-
electric media
minimum 10 mm (0.4”)
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR250 C) 7ML 5 4 3 1 - SITRANS LR250 C) 7 M L 5 4 3 1 -
2-wire, 25 GHz pulse radar level transmitter for con- 77 7 7 0 - 77 77 2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 7 0 - 7 7 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). Ideal for and pressure, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media. small vessels and low dielectric media.
Process Connection and Antenna Material Further designs Order code
316L (1.4435 or 1.4404) stainless steel, PTFE emit- 0 Please add “-Z” to Order No. and specify Order
ter, FKM seal code(s).
316L (1.4435 or 1.4404) stainless steel, PTFE emit- 1
ter, FFKM seal Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Hastelloy C-22/2.4602, PTFE emitter, FKM seal1) 2
Hastelloy C-22/2.4602, PTFE emitter, FFKM seal1) 3 Inspection Certificate Type 3.1 per EN 10204 C12
Process Connection Type Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
1½” NPT [(Taper), ANSI/ASME B1.20.1]2) AA Measuring-point number/identification (max. 27
R 1½” [(BSPT), EN 10226]2) AB characters) specify in plain text
G 1½” [(BSPP), EN ISO 228-1] (parallel thread)2) AC Instruction manual for HART/mA device Order No.
2" NPT [(Taper), ANSI/ASME B1.20.1] AD English C) 7ML1998-5JE01
R 2" [(BSPT), EN 10226] AE German C) 7ML1998-5JE31
G 2" [(BSPP), EN ISO 228-1] (parallel thread) AF Note: The instruction manual should be ordered
as a separate line item on the order.
2" ASME, 150 lb BA
5
3" ASME, 150 lb BB Multi-language Quick Start manual C) 7ML1998-5QX81
4" ASME, 150 lb BC This device is shipped with the Siemens Milltronics
2" ASME, 300 lb CA manual CD containing the complete ATEX Quick
3" ASME, 300 lb CB Start and instruction manual library.
4" ASME, 300 lb CC Instruction manual for PROFIBUS device
DN 50 PN16 DA English C) 7ML1998-5JF01
German C) 7ML1998-5JF31
DN 80 PN16 DB
Note: The instruction manual should be ordered
DN 100 PN16 DC
as a separate line item on the order.
DN 50 PN40 EA
Multi-language Quick Start manual C) 7ML1998-5XE81
DN 80 PN40 EB
DN 100 PN40 EC This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
JIS 50A 10K FA Start and instruction manual library.
JIS 80A 10K FB
JIS 100A 10K FC Accessories
(Note: Stainless steel flanges provided as flat Handheld programmer, Intrinsically Safe, EEx ia C) 7ML1930-1BK
faced; Hastelloy flanges provided as raised face. (LUI enabled)
Flange bolting patterns and facings dimensionally HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
correspond to the applicable ASME B16.5, or SIMATIC PDM)
EN 1092-1, or JIS B 2238 standard.) One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
Communication/Output +80 °C (-40 to +176 °F)
4 to 20 mA, HART® 0 One metallic cable gland M20 x 1.5, rated -40 to 7ML1930-1AQ
PROFIBUS PA 1 80 °C (-40 to 176 °F), PROFIBUS PA
Enclosure/Cable inlet 1) Not available with process connection options AA to AF
Aluminum, Epoxy painted 2) For 1½” horn antennas only, max. range 10 m (32.8 ft), dk > 3
2 x ½” NPT 0 3)
2 x M20x1.5 1 For 1½” threaded connection only, max. range 10 m (32.8 ft), dk > 3
Antenna C) Subject to export regulations AL: N, ECCN: EAR99
1½” horn3) A D) Subject to export regulations AL: N, ECCN: EAR99H
2" horn (fits 2" ASME or DN 50 nozzles) B
3" horn (fits 3" ASME or DN 80 nozzles) C
4" horn (fits 4" ASME or DN 100 nozzles) D
1½” horn with 100 mm extension2) E
2" horn with 100 mm extension F
3" horn with 100 mm extension G
4" horn with 100 mm extension H
(Note: Please use largest horn size possible.)
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, A
C-TICK
CSA/FM Class I and II, Div. I, Groups A,B, C, D, E, B
F, G Intrinsically safe, barrier required, FCC,
C-TICK
ATEX II 1 GD EEx ia IIC T4, Intrinsically safe, barrier C
required, R&TTE, C-TICK, INMETRO
CSA/FM Class I, Div. 2, Non-Incendive, no barrier D
required, FCC, C-TICK
Pressure rating
Rating per Pressure/Temperature curves in Manual 0
0.5 bar (7.25 psi) maximum 1
■ Selection and Ordering Data SITRANS LR250 horn antenna and extension
kits
SITRANS LR250 Spare parts
SITRANS LR250 Enclosures
SITRANS LR250 enclosure with board stack, M20 A5E01156824 100 mm (4") horn antenna kit, Hastelloy C-22 A5E01151587
5
cable inlet, approval option B, with HART com- 5 Dupont 1Gr Polyback, PTFE grease kit A5E01151626
munication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156827
cable inlet, approval option C, with HART com-
munication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156832
cable inlet, approval option C, with HART com-
munication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156834
cable inlet, approval option D, with HART com-
munication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156835
cable inlet, approval option D, with HART com-
munication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156836
cable inlet, approval option A, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156838
cable inlet, approval option A, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156839
cable inlet, approval option B, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156841
cable inlet, approval option B, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156843
cable inlet, approval option C, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156844
cable inlet, approval option C, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, NPT A5E01156846
cable inlet, approval option D, with PROFIBUS
communication, no process connection
SITRANS LR250 enclosure with board stack, M20 A5E01156848
cable inlet, approval option D, with PROFIBUS
communication, no process connection
■ Dimensional drawings
■ Schematics
Connect thederwires
Anschluss Drähte
wiethe
to abgebildet:
terminals Die
as
Polaritätthe
shown: ist polarity
auf den
Klemmen
is identifiedgekenn-
on the
zeichnet.block.
terminal
Shield for
Schirm nurHART
für eigensichere
and PROFIBUS
HARTPAund
Instrinsically
Kabelverschraubung
gland PROFIBUS
Safe versionsPAonly.
Ausführungen.
Hinweise:
5 Remaques
2. DC
1.
:
1. Um die Sicherheitsanforderungen
Alleterminal
Feldanschlüsse
shall be müssen
der IEC 61010-1 zu erfüllen, sind Gleichstromklemmen von einer Quelle zu versorgen, die eine galvanische Trennung zwischen Ein- und Ausgang bewirkt.
suppliedentsprechend
from a sourceder angelegten
providing Eingangsspannung
electrical isoliert
isolation between sein.and output, to meet the applicable safety requirements of IEC 61010-1.
the input
3. All
2. Verwenden Siemust
field wiring geschirmtes Kabel mit
have insulation verdrilltem
suitable Aderpaar
for rated (14 ... 22 AWG) für die HART Ausführung.
input voltages.
4. Use
3. Eineshielded
getrenntetwisted
Leitungsverlegung
pair cable (14kann
to 22erforderlich sein, um
AWG) for HART Standardanforderungen an den Anschluss oder elektrische Richtlinien zu erfüllen.
version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
Handprogrammiergerät
Hand Programmer SITRANS LR250
SITRANS LR250
HART
HART
Part number:
Artikelnummer:
7ML1930-1BK
7ML1930-1BK
■ Overview
5
SITRANS LR300 is a 4-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).
■ Benefits
• Auto False-Echo Suppression
• Infrared Intrinsically Safe handheld or remote programming
• 5.8 GHz (U.S.A. 6.3 GHz)
• Built-in diagnostics
• Various flanges, horn and waveguide antenna options avail-
able
• Extremely high signal-to-noise ratio
■ Application
The SITRANS LR300 is available both for standard applications
and for applications that require explosion proof protection.
The SITRANS LR300 features a compact design and robust con-
struction and is available with an epoxy-coated aluminum or
stainless steel enclosure. Operating at low frequency and high
signal transmission speed, it is virtually unaffected by atmo-
spheric or temperature conditions. It provides reliable measure-
ment in environments with harsh chemicals, steam, dust, en-
crustation, turbulence and agitation.
The high resistance PTFE rod antenna is chemically immune and
resistant to material buildup. The SITRANS LR300 can commu-
nicate using the following protocols: Modbus®, HART® or op-
tional PROFIBUS PA.
When using the flange or threaded antenna options, the
SITRANS LR300 is easily installed by positioning the unit on a
standpipe, bolting or threading it in place and connecting it to
the power supply. There’s no need to fill or empty the vessel for
calibration or commissioning.
• Key Applications: liquid bulk storage tanks, agitated process
vessels
■ Configuration
Installation Mounting unit on bypass Mounting unit on stilling well
Orient display
at 90° to the vent.
Orient display
optimum at 90° to
diameter stillpipe slots.
80 mm (3”)
5
Mounting unit on vessel Clearance: Shielded Rod Clearance: Horn Antenna
P a ra b o lic
Coni cal
minimum 10 mm (0.4”)
minimum 10 mm (0.4”)
Conical Flat Parabolic
• Analog output Optically isolated, 4 to 20 mA • Explosion Proof • ATEX II 1/2 G EEx de IIC T6
• ATEX II 1/2 G EEx de [ia] IIC T6
- Load Max. 450 Ω
• CSA Class I, Div 1, Groups A, B,
- Accuracy 0.02 mA C, D, E, F, G
• Communications Modbus/RS-485 connection, • FM Class I, Div.1, Groups A, B,
HART® or optional PROFIBUS PA C, D, E, F and G
Performance (reference condi- • Sanitary 3A Sanitary (Sanitary rod antenna
tions) only)
• Error in measurement at +20 °C ± 15 mm from 0.4 to 10 m Communication
(+68 °F) ± 0.15% from 10 to 20 m
5
• Intrinsically Safe Siemens Infrared receiver
- Temperature drift < ± 0.25% of range, Milltronics handheld programmer
-40 to +60 °C (-40 to +140 °F)
- Approvals for handheld pro- IS model with ATEX EEx ia IIC T4,
- Repeatability ± 2 mm, up to 3 m grammer CSA/FM Class I, Div. 1, Groups A,
± 3 mm, from 3 m to 5 m B, C, D
± 5 mm, from 5 m to 10 m
± 10 mm, from 10 m to 20 m • Programmer (remote keypad) Modbus, HART or optional
PROFIBUS PA;
- Fail-safe mA signal programmable as high, upgradable Flash via RS-485
low or hold (Loss of Echo)
• PC SIMATIC PDM
Rated operating conditions
• Display (local) Alphanumeric and multi-graphic
Installation conditions liquid crystal for readout and
entry
• Location Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature -40 to +60 °C (-40 to +140 °F)
• Installation category II
• Pollution degree 4
Medium conditions
• Dielectric constant εr εr > 1.6 (For εr < 3, use
waveguide antenna or stillpipe)
• Temperature -40 to +200 °C (-40 to +392 °F)
• Pressure (vessel) Dependent on process connec-
tion and temperature (refer to
Pressure/Temperature curves)
Design
• Enclosure
- Material Aluminium, epoxy coated or
optional stainless steel
- Cable inlet 2 x ½" NPT or M20x1.5
• Degree of protection Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
• Weight 6.5 kg (14.3 lbs) with 2"/150 psi
flange; weight varies depending
on flange size and pressure rating
• Dielectric rod antennas
- Material PTFE
- Dimensions 41 cm (16.3") long including inte-
gral gasket (other antenna types
available)
Process connections
• Flange Flat faced flanges: 316L stainless
steel, 50, 80, 100, 150, 200 mm
(2, 3, 4, 6, 8"), bolt hole pattern to
ASME, DIN and JIS sizes
• Other connections Available
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, horn antenna version C) 7 M L 5 4 1 1 - SITRANS LR300, horn antenna version C) 7 M L 5 4 1 1 -
4-wire, 6 GHz pulse radar level transmitter for con- 77 7 77 - 77 77 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version 100 mm (4”) horn with 250 mm (10”) waveguide J
Stainless steel 316L with PTFE emitter 0 extension3)
Stainless steel 316L with PTFE emitter and purging 1 150 mm (6”) horn with 100 mm (4”) waveguide K
kit1) extension
Sliding waveguide system 1000 mm (40”) 2 150 mm (6”) horn with 150 mm (6”) waveguide L
long1) and 2) extension
150 mm (6”) horn with 200 mm (8”) waveguide M
Flange design (Flat faced, 316L Stainless Steel) extension
DN 50 PN 16, Type A, flat faced1) AA
DN 80 PN 16, Type A, flat faced BA 150 mm (6”) horn with 250 mm (10”) waveguide N
extension
DN 100 PN 16, Type A, flat faced CA
200 mm horn with 100 mm (4”) waveguide exten- P
DN 150 PN 16, Type A, flat faced DA sion
DN 200 PN 16, Type A, flat faced EA 200 mm horn with 150 mm (6”) waveguide exten- Q
2" ASME, 150 lb1) FB sion
3" ASME, 150 lb, flat faced GB 200 mm (8”) horn with 200 mm (8”) waveguide R
extension
5
4" ASME, 150 lb, flat faced HB
6" ASME, 150 lb, flat faced JB 200 mm (8”) horn with 250 mm (10”) waveguide S
extension
8" ASME, 150 lb, flat faced1) KB Waveguide only - Waveguide length 500 mm to T
DN 50 PN 40, flat faced1) AC 3000 mm (in 1 mm increments) (Add order code
DN 80 PN 40, flat faced BC Y01 and plain text: “waveguide length ...mm”)
Horn with custom waveguide lengths 101 to U
DN 100 PN 40, flat faced CC 2000 mm (Add order code Y01 and plain text:
DN 150 PN 40, flat faced DC “waveguide length...mm”, and Add order code Y03
DN 200 PN 40, flat faced EC and plain text: “horn size ...mm”)4)
2" ASME, 300 lb, flat faced1) FD Approvals
3" ASME, 300 lb, flat faced GD General Purpose, CE, CSAUS/C5) A
4" ASME, 300 lb, flat faced HD CSA Class I, Div 1, Groups A, B, C, D, E, F, G, CE5) D
6" ASME, 300 lb, flat faced JD ATEX II 1/2 G EEx de IIC T6, CE 5) and 6) E
8" ASME, 300 lb, flat faced KD FM Class I, Div 1, Groups A, B, C, D, E, F, G, FCC, F
JIS DN 50 10K1) AE 6.3 GHz, for U.S.A. only
General Purpose, FM, FCC, 6.3 GHz, for U.S.A. G
JIS DN 80 10K BE only
JIS DN 100 10K CE ATEX II 1/2 G EEx de [ia] IIC T6 J
JIS DN 150 10K DE
Pressure rating
JIS DN 200 10K EE Rating per Pressure/Temperature curves in manual 0
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5, 0.5 bar (7.25 psi maximum) 1
or EN 1092-1, or JIS B 2238 standard.) Further designs Order code
Communication/output Please add “-Z” to Order No. and specify Order
4 to 20 mA, HART®, Modbus 0 code(s).
PROFIBUS PA, Modbus 1 Acceptance test certificate: Manufacturer's test C11
Process seal/Gasket certificate M to DIN 55350, Part 18 and to ISO 9000
FKM 0 Inspection Certificate Type 3.1 per EN 10204 C12
Nitrile, only for sliding waveguide systems 1 Y15
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]:
FFKM [-35 to +200 °C (-31 to +392 °F)] 2 Measuring-point number/identification (max. 16
Enclosure/Cable inlet characters) specify in plain text
Aluminum, Epoxy painted Horn with waveguide extension custom lengths: Y01
2 x ½" NPT 0 Enter the total length of the waveguide in plain text
2 x M20x1.5 1 description (1 mm increments)
Enter the Horn size in plain text description Y03
Stainless steel 316L
2 x ½" NPT 2 [100 mm (3.94”), 150 mm (5.91”), and 200 mm
(7.87”) only]
2 x M20x1.5 3
Horn size/Waveguide options
80 mm (3”) horn3) B
100 mm (4”) horn3) C
150 mm (6”) horn D
200 mm (8”) horn E
100 mm (4”) horn with 100 mm (4”) waveguide F
extension3)
100 mm (4”) horn with 150 mm (6”) waveguide G
extension3)
100 mm (4”) horn with 200 mm (8”) waveguide H
extension3)
5
Tag, stainless steel with hole, 7ML1930-1BJ
12 x 45 mm (0.47 x 1.77”), for fastening on
mounting-eye, one text line, (e.g. for Sensors)
HART® modem/RS-232 (for use with a PC and D) 7MF4997-1DA
SIMATIC PDM)
HART modem/USB (for use with a PC and D) 7MF4997-1DB
SIMATIC PDM)
RS 485 to RS 232 converter, not isolated, C) 7ML1830-1HA
port powered
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
+80 °C (-40 to +176 °F) for General Purpose or
ATEX EEx e installations (available for HART only)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
nection (available for PROFIBUS PA)
1)
Available with pressure rating option 1 only
2)
Available with horn size option C, D, E only
3)
For stilling well applications only
4)
Order standard waveguide lengths 100, 150, 200, 250 mm (3.93, 5.91,
7.87, 9.84”) by choosing options from Horn size/Waveguide options
5)
Includes European Radio and Industry Canada approvals, 5.8 GHz
6)
Available with communication option 0 only
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, sanitary version C) 7 M L 5 4 1 2 - SITRANS LR300, sanitary version C) 7 M L 5 4 1 2 -
4-wire, 6 GHz pulse radar level transmitter for con- 77 7 77 - 77 77 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version Instruction manual
PTFE, one piece rod antenna 0 English C) 7ML1998-5CL05
UHMW-PE, one piece rod antenna 1 French C) 7ML1998-5CL14
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, rod antenna version C) 7 M L 5 4 1 3 - SITRANS LR300, rod antenna version C) 7 M L 5 4 1 3 -
4-wire, 6 GHz pulse radar level transmitter for con- 77 7 77 - 77 77 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version Approvals
PTFE 0 General Purpose, CE, CSAUS/C6) A
Process connection CSA Class I, Div I, Groups A, B, C, D, E, F, G, CE6) D
Flange version (Flat faced, 316L Stainless Steel) ATEX II 1/2 G EEx de IIC T6, CE7) E
DN 50 PN 16, Type A, flat faced AA FM Class I, Div I, Groups A, B, C, D, E, F, G, FCC, F
DN 80 PN 16, Type A, flat faced BA 6.3 GHz, for U.S.A. only
DN 100 PN 16, Type A, flat faced CA General Purpose, FM, FCC, 6.3 GHz, for U.S.A. G
only
DN 150 PN 16, Type A, flat faced DA
ATEX II 1/2 G EEx de [ia] IIC T6 J
2” ASME, 150 lb, flat faced FB
Pressure rating
3" ASME, 150 lb, flat faced GB
Rating per Pressure/Temperature curves in manual 0
4" ASME, 150 lb, flat faced HB 0.5 bar (7.25 psi maximum) 1
6" ASME, 150 lb, flat faced JB
Further designs Order code
DN 50 PN 40, flat faced AC
Please add “-Z” to Order No. and specify Order
DN 80 PN 40, flat faced BC
code(s).
DN 100 PN 40, flat faced CC Acceptance test certificate: Manufacturer's test
5
C11
DN 150 PN 40, flat faced DC certificate M to DIN 55350, Part 18 and to ISO 9000
2” ASME 300 lb, flat faced1) FD Inspection Certificate Type 3.1 per EN 10204 C12
3" ASME, 300 lb, flat faced GD Inactive custom shield lengths: Enter the total Y01
4" ASME, 300 lb,flat faced HD length of the inactive shield in plain text description
6" ASME, 300 lb, flat faced JD (in 1 mm increments).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
JIS DN 50 10K AE Measuring-point number/identification (max. 16
JIS DN 80 10K BE characters) specify in plain text
JIS DN 100 10K CE Instruction manual Order No.
JIS DN 150 10K DE English C) 7ML1998-5CL05
(Note: Flange bolting patterns and facings dimen- French C) 7ML1998-5CL14
sionally correspond to the applicable ASME B16.5, German C) 7ML1998-5CL34
or EN 1092-1, or JIS B 2238 standard.) Note: Instruction manual should be ordered as a
Threaded version (316L Stainless Steel) separate line item on the order.
1½" NPT [(Taper), ANSI/ASME B1.20.1] LA Multi-language Quick Start manual C) 7ML1998-5QA85
2" NPT [(Taper), ANSI/ASME B1.20.1] MA
This device is shipped with the Siemens Milltronics
R 1½" [(BSPT), EN 10226] LC manual CD containing the complete ATEX Quick
R 2" [(BSPT), EN 10226] MC Start and instruction manual library.
G 1½" [(BSPP), EN ISO 228-1] LE Accessories
G 2" [(BSPP), EN ISO 228-1] ME Handheld programmer for SITRANS LR300, Intrin- C) 7ML5830-2AH
Antenna extension, or inactive shield length sically Safe, EEx ia
Without antenna extension 0 Antenna rod, PTFE 7ML1830-1HC
PTFE extension Antenna extension, 50 mm (2”), PTFE 7ML1830-1CH
50 mm (1.97”) 1 Antenna extension, 100 mm (4”), PTFE 7MH1830-1CG
100 mm (3.94”) 2 Tag, stainless steel with hole, 7ML1930-1BJ
Stainless steel 316L extension2) 12 x 45 mm (0.47 x 1.77”), for fastening on mount-
100 mm (3.94”) 3 ing-eye, one text line, (e.g. for Sensors)
150 mm (5.91”) 4 Enclosure wrench 7ML1830-1HB
200 mm (7.87”) 5 HART® modem/RS-232 (for use with a PC and D) 7MF4997-1DA
250 mm (9.84”) 6 SIMATIC PDM)
HART modem/USB (for use with a PC and D) 7MF4997-1DB
Custom inactive shield length 101 mm to 1000 mm 7 SIMATIC PDM)
(in 1 mm increments) Add order code Y01 and
RS 485 to RS 232 converter, not isolated, port C) 7ML1830-1HA
plain text: “Inactive shield length...mm”2)
powered
Process Seal/Gasket
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
Integral Gasket3) and 4) 0 +80 °C (-40 to +176 °F) for General Purpose or
FKM O-ring5) 1 ATEX EEx e installations (available for HART only)
Enclosure/Cable inlet One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
Aluminum, Epoxy painted +80 °C (-40 to +176 °F with integrated shield con-
2 x ½" NPT 0 nection (available for PROFIBUS PA)
2 x M20x1.5 1 1)
For use with pressure rating option 1 only
316L Stainless steel 2)
For use with all process connection options except AA, FB, AC, FD, AE,
2 x ½" NPT 2 LA, LC and LE
2 x M20x1.5 3 3) Available with flat faced flange process connections only
4)
Communication/output Available with antenna extension options 0, 1, 2 only
5)
4 to 20 mA, HART®, Modbus A Not available for combination of flat faced flanges with antenna extension
PROFIBUS PA, Modbus B options 0, 1 or 2
6) Includes European Radio and Industry Canada approvals, 5.8 GHz
7)
Not available with Communication option B
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H
■ CCharacteristic curves
■ Schematics
■ Dimensional drawings
■ Integration
■ Technical specifications
Antenna Types Flat Faced Flange Shielded Rod Sanitary Rod Horn (4", 6", 8" sizes Waveguide
with Rod (1 piece construction) available)
Connection Type Flat faced flange Threaded 2" NPT, R 2” Sanitary fitting clamp Flat faced flange Flat faced flange
nominal pipe sizes 50, (BSPT), G 2” (BSPP) or 50, 80, 100 mm (2, 3, nominal pipe sizes 50, nominal pipe sizes 50,
80, 100, 150 mm (2, 3, flat faced flange 4") sizes 80, 100, 150 mm (2, 3, 80, 100, 150 mm (2, 3,
4, 6") nominal pipe sizes 80, 4, 6") 4, 6")
100 mm (3, 4")
Wetted Parts PTFE PTFE, 316L stainless UHME-PE or PTFE 316L stainless steel 316L stainless steel
steel, FKM o-ring PTFE, FKM o-ring PTFE, FKM o-ring
Extensions 50 or 100 mm (2" or 4") 100, 150, 200 or N/A use waveguide for two sections (max.)
PTFE or UHMW-PE 250 mm (4, 6, 8 or 10") extensions to 6 m can be connected
standard shield length (20 ft) long together
Max. overall length:
3 m (9.8 ft)
Dielectric Constant >3 >3 >3 >3 > 1.6
Insertion Length 41 cm (16.3") variable 41 cm (16.3") variable with extension variable
(max.)
Purging Option No No No Yes Yes
(Liquid or Gas)
Sliding Waveguide Yes No No Yes N/A
Option for Digesters2)
Weight3) 6.5 kg (14.3 lbs) 5.0 kg (11 lbs) 5.0 kg (11 lbs) 7.5 kg (16.5 lbs) 8.0 kg (17.6 lbs)
1 m (39”) length
1) 1) 1) 1)
Approvals 3A
1)
Please see a Siemens Milltronics representative for a list of safety and radio approvals.
2)
Maximum pressure 0.5 bar at +60 °C (7.25 psi at +140 °F)
3)
Not including extensions, includes SITRANS LR200 or SITRANS LR300 and smallest process connection
5
SITRANS LR200/LR300 PTFE Rod Antenna Kit
with 316L SS 2" pipe thread process connec- PTFE sanitary rod antenna kit, 4" mounting con- PBD-
tion nection. See note 6. 51010K3AA
UHMW-PE sanitary rod antenna kit, 2" mounting PBD-
connection. See note 6. 51010K1AB
UHMW-PE sanitary rod antenna kit, 3" mounting PBD-
connection. See note 6. 51010K2AB
PTFE rod antenna kit, 2" NPT 316L SS Process PBD-
Connection, FKM O-ring; See drawing 51005 on 51005K1AAA UHMW-PE sanitary rod antenna kit, 4" mounting PBD-
http://www.siemens.com/radar. See note 6. connection). See note 6. 51010K3AB
PTFE rod antenna kit, R 2" (BSPT), EN 10226 PBD- SITRANS LR200/LR300 PTFE Flanged Rod
316L SS Process Connection, FKM O-ring; See 51005K2AAA Antenna Kit with 316L SS shield and 316L SS
drawing 51005 on flat faced flange
http://www.siemens.com/radar. See note 6.
PTFE rod antenna kit, 2" G 316L SS Process Con- PBD-
nection, FKM O-ring; See drawing 51005 on 51005K3AAA
http://www.siemens.com/radar. See note 6.
SITRANS LR200/LR300 PTFE Rod Antenna Kit PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
(100 mm shield) with 316L SS 2" pipe thread 150 lb 316L SS flange, 100 mm 316L SS shield. 51014K0100AAA
process connection See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 100 mm 316L SS shield. 51014K0100EJA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
PTFE rod antenna shielded kit, 2" NPT 316L SS PBD- 150 lb 316L SS flange, 150 mm 316L SS shield. 51014K0150AAA
Process Connection, FKM O-ring, 100 mm 51002K0100AAA See notes 1 and 6.
316L SS shield. See drawing 51002 on
http://www.siemens.com/radar. See notes 3 and 6. PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 150 mm 316L SS shield. 51014K0150EJA
PTFE rod antenna shielded kit, R 2" (BSPT), EN PBD- See notes 1 and 6.
10226 316L SS Process Connection, FKM O- 51002K0100BAA
ring, 100 mm PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
316L SS shield. See drawing 51002 on 150 lb 316L SS flange, 200 mm 316L SS shield. 51014K0200AAA
http://www.siemens.com/radar. See notes 3 and 6. See notes 1 and 6.
PTFE rod antenna shielded kit, 2" G 316L SS PBD- PTFE shielded rod antenna kit, flanged, DN 80 PBD-
Process Connection, FKM O-ring, 100 mm 51002K0100CAA PN 16 316L SS flange, 200 mm 316L SS shield. 51014K0200EJA
316L SS shield. See drawing 51002 on See notes 1 and 6.
http://www.siemens.com/radar. See notes 3 and 6. PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
SITRANS LR200/LR300 Horn Antenna Kit with 150 lb 316L SS flange, 250 mm 316L SS shield. 51014K0250AAA
316L SS flat faced flange, with PTFE emitter See notes 1 and 6.
(without waveguide) PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 250 mm 316L SS shield. 51014K0250EJA
See notes 1 and 6.
■ Characteristic curves
■ Overview ■ Application
It provides excellent results on low dielectric media.
SITRANS LR400 is available for standard applications and for
applications that require explosion proof protection.
SITRANS LR400 features robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temper-
ature conditions within the vessel.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming.
The characteristics of 24 GHz and high signal-to-noise ratio con-
tribute to exceptional signal reflection, regardless of the dielec-
tric value of the medium.
• Key applications: long-range liquid or slurry applications, high
temperature or high pressure, low dielectric media, such as
L.P.G. (liquid, petroleum, gas).
■ Configuration
5
• ABS
• Error in measurement at +25 °C ≤ 5 mm from 2 to 10 m
(+77 °F) ≤ 15 mm from 10 to 50 m • Radio Europe (R&TTE, CETECOM),
Industry Canada, FCC
- Repeatability ≤ 1 mm
• Hazardous areas ATEX II 1/2 G EEx dem [ia] IIC T6
- Fail-safe mA signal programmable as high,
low or hold (LOE) ATEX II 1/2 G EEx dem IIC T6
CSA/FM Class I, Div. 1, Groups B,
Rated operating conditions C, D; Class II, Div. 1, Groups E, F,
• Amb. temperature for enclosure -40 to +65 °C (-40 to +149 °F) G; Class III T6
• Location Indoor/outdoor Optional equipment Purging (self-cleaning) system
• Installation category II PTFE dust cover
• Pollution degree 4
Medium conditions
Dielectric constant εr>1.4
Process temperature range
• Standard -40 to +200 °C (-40 to +392 °F)
-20 to +200 °C (-4 to +392 °F) for
SITRANS LR400 with ATEX rating
• With optional temperature exten- -40 to +250 °C (-40 to +482 °F)
sion
Vessel Pressure Up to 40 bar (process connection
dependent)
Design
Weight Approx. 12.2 kg (26.8 lbs) with 3"
150 psi flange
Materials
• Enclosure Die-cast aluminum, painted
• Degree of protection IP67/Type 4X/NEMA 4X,
Type 6/NEMA 6
• Cable inlet 2x M20x1.5 or ½" NPT
Process connections
• Flat-faced flanges 316L stainless steel, 80, 100,
150 mm, bolt holes matching
EN 1092-1 and JIS B 2238
• Raised face flanges 316L stainless steel, 3", 4", 6", bolt
holes matching ASME B 16.5
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR400 C) 7 M L 5 4 2 1 - SITRANS LR400 C) 7 M L 5 4 2 1 -
4-wire, 24 GHz FMCW radar level transmitter for 77 7 77 - 77 77 4-wire, 24 GHz FMCW radar level transmitter for 7 7 7 77 - 77 7 7
continuous monitoring of liquids and slurries in stor- continuous monitoring of liquids and slurries in stor-
age and process vessels including high tempera- age and process vessels including high tempera-
ture and high pressure, to a range of 50 m (164 ft); ture and high pressure, to a range of 50 m (164 ft);
ideal for low dielectric media. ideal for low dielectric media.
Order handheld programmer separately! Order handheld programmer separately!
Process temperature range ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, L
-40 °C to +200 °C (-40 to +392 °F), standard 0 R&TTE2) and 4)
-40 °C to +250 °C (-40 to +482 °F), high tempera- 1 ATEX II 2G EEx d IIC T6; CE, CETECOM3) M
ture extension ATEX II 2G EEx dem IIC T6; CE, CETECOM3) N
Process connection ATEX II 2G EEx dem [ia] IIC T6; CE, P
Universal, 0.5 bar (7.25 psi) maximum CETECOM2) and 3)
3"/80 mm1) A ATEX II 1/2 GD EEx d IIC T6; CE, CETECOM3) and 4) Q
4"/100 mm1) B ATEX II 1/2 GD EEx dem IIC T6; CE, R
6"/150 mm1) D CETECOM3) and 4)
DN 80, PN 16, Type A, flat faced S ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, S
DN 80, PN 40, Type B1, raised face C CETECOM2), 3) and 4)
DN 100, PN 16, Type A, flat faced T FM Class I, Div. 1, Groups B, C, D; Class II/III, T
Div. 1, Groups E, F, G; FCC4)
DN 100, PN 40, Type B1, raised face G
5
CSA Class I, Div. 1, Groups B, C, D; Class II/III, U
DN 150, PN 16, Type A, flat faced U Div. 1, Groups E, F, G; FCC4)
3" ASME, 150 lb, raised face E
Local operation
3" ASME, 300 lb, raised face F
Local Display Only. Handheld programmer not 2
4" ASME, 150 lb, raised face J included (Order programmer separately.)
4" ASME, 300 lb, raised face K Further designs Order code
6" ASME, 150 lb, raised face N Please add “-Z” to Order No. and specify Order code(s).
JIS, DN 80 10K Q
JIS, DN 100 10K R Manufacturer’s test certificate M to DIN 55350, C11
Part 18 and to ISO 9000
JIS, DN 150 10K V
(Note: Flange bolting patterns and facings dimen- Inspection Certificate Type 3.1 per EN 10204 C12
sionally correspond to the applicable ASME B16.5, Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
or EN 1092-1, or JIS B 2238 standard.) Measuring-point number/identification (max. 16
characters); specify in plain text
Antenna
Horn antenna, long 93 mm (3.66") diam. for D Instruction manual Order No.
100 mm (4") nozzles English C) 7ML1998-5FH06
Horn antenna, short 74 mm (2.91") diam. for 80 mm K German C) 7ML1998-5FH36
(3") nozzles French C) 7ML1998-5FH15
Antenna purging system Multi-language Quick start manual C) 7ML1998-5QN83
None 0 This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Purging system 1 Start and instruction manual library.
Note: Available with process connections A, B or D,
only, and available for Area Classifications A or B Accessories
only Handheld programmer Intrinsically Safe, EEx ia C) 7ML5830-2AJ
Process seal/gasket Long horn dust cover, PTFE 7ML1930-1AH
PTFE for -40 to +250 °C (-40 to +482 °F) flange 1 Short horn dust cover, PTFE 7ML1930-1AJ
temperatures HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
FKM for -20 to +200 °C (-4 to +392 °F) flange 3 SIMATIC PDM)
temperatures4) HART modem/USB (for use with a PC and D) 7MF4997-1DB
Output/Communication SIMATIC PDM)
4 to 20 mA, HART 0 One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
PROFIBUS PA 1 +80 °C (-40 to +176 °F) for General Purpose or
ATEX EEx e installations (available for HART only)
Power supply/cable inlet One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
120 to 230 V AC +80 °C (-40 to +176 °F) with integrated shield con-
• 2 x M20x1.5 B nection (available for PROFIBUS PA)
• 2 x ½“ NPT C 1) Available with antenna purging system option 1 only
24 V DC 2) Available only with power supply option E or F
• 2 x M20x1.5 E 3) Germany and Belgium end customers only
• 2 x ½“ NPT F 4) Available with process temperature range option 0 only
Area classification
C) Subject to export regulations AL: N, ECCN: EAR99
General Purpose, CE, CETECOM3) A
General Purpose, CSAUS/C, Industry Canada, FCC, B D) Subject to export regulations AL: N, ECCN: EAR99H
CE and R&TTE
ATEX II 2G EEx d IIC T6; CE, R&TTE E
ATEX II 2G EEx dem IIC T6; CE, R&TTE F
ATEX II 2G EEx dem [ia] IIC T6; CE, R&TTE2) G
ATEX II 1/2 GD EEx d IIC T6; CE, R&TTE3) J
ATEX II 1/2 GD EEx dem IIC T6; CE, R&TTE4) K
5
See note 2.
Purging kit with Easy Aimer PBD-
ball with 6"/150 mm flange, no 51035811 SITRANS LR400 Aluminum C) PBD-
horn. See note 1. enclosure with DC power, M20 51036483
cable inlet, HART communica-
Purging Kit with Easy Aimer PBD- tion and GP, CE, CSA, Industry
ball with 8"/200 mm flange, no 51035812 Canada, FCC and R&TTE.
horn. See note 1. See note 2.
Short horn antenna, no emitter PBD- SITRANS LR400 Aluminum C) PBD-
supplied 22475K1A enclosure with DC power, M20 51036484
Long horn antenna, no emitter PBD- cable inlet, PROFIBUS PA
supplied 22475K2A communication and GP, CE,
CSA, Industry Canada, FCC
Short horn antenna, purged, PBD- and R&TTE. See note 2.
no emitter supplied 22475K3A
SITRANS LR400 Aluminum C) PBD-
Long horn antenna, purged, PBD- enclosure with DC power, M20 51036485
no emitter supplied 22475K4A cable inlet, HART communica-
tion and ATEX II 1/2 GD EEx d
Replacement display module, PBD- IIC T6, CE and R&TTE approv-
SITRANS LR400 Liquids and 51035410 als. See note 2.
Solids versions
SITRANS LR400 Aluminum C) PBD-
4" Horn antenna extension kit PBD- enclosure with DC power, M20 51036486
with General Purpose approv- 51035474 cable inlet, PROFIBUS PA
als communication and ATEX II
8" Horn antenna extension kit PBD- 1/2 GD EEx d IIC T6, CE and
with General Purpose approv- 51035473 R&TTE approvals. See note 2.
als
Note 1: Available with no pressure rating and with General Pur-
8" Horn antenna extension kit PBD- pose approvals only
for hazardous units 51036180
SITRANS LR400 Aluminum C) PBD-
Note 2: Subject to export regulations AL: N, ECCN: EAR99
enclosure with AC power, M20 51036479 Please contact nacc.smpi@siemens.com for special requests.
cable inlet, HART® communi-
cation, and GP, CE, and C) Subject to export regulations AL: N, ECCN: EAR99
CETECOM approvals.
See note 2.
SITRANS LR400 Aluminum C) PBD-
enclosure with AC power, M20 51036480
cable inlet, PROFIBUS PA
communication and GP, CE,
and CETECOM approvals.
See note 2.
SITRANS LR400 Aluminum C) PBD-
enclosure with AC power, M20 51035867
cable inlet, HART communica-
tion and GP, CE, CSA, Industry
Canada, FCC and R&TTE.
See note 2.
SITRANS LR400 Aluminum C) PBD-
enclosure with AC power, M20 51035871
cable inlet, PROFIBUS PA
communication and GP, CE,
CSA, Industry Canada, FCC
and R&TTE. See note 2.
■ Characteristic curves
■ Dimensional drawings
■ Schematics
■ Overview ■ Application
SITRANS LR460 provides excellent results even during condi-
tions of extreme dust. The integral Easy Aimer included on the
SITRANS LR460 allows for easy positioning for optimum mea-
surement on solids.
Process Intelligence onboard SITRANS LR460 means advanced
signal processing is harnessed for reliable operation on both
simple and difficult solids application.
SITRANS LR460 features a robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temper-
ature conditions within the vessel.
An optional dust cap is available for sticky solids. Optional air
purging is also available for extremely sticky applications.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming using HART or PROFIBUS PA.
The characteristics of 24 GHz and high signal-to-noise ratio con-
tribute to exceptional signal reflection, regardless of the dielec-
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level trans- tric value of the medium.
5 mitter with extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of solids up to
100 m (328 ft). It is ideal for measurement in extreme dust.
• Key applications: long-range dusty applications, cement pow-
der, fly-ash, coal, flour, grain, plastics
■ Benefits
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided quick start wizard for plug and play start-up
• 24 GHz provides superior reflective properties on solids sur-
faces
• 100 m (328 ft) range for long-range and difficult applications
• Easy Aimer optimizes signal quality on sloped surfaces
• Programming using infrared Intrinsically Safe handheld pro-
grammer or with SIMATIC PDM or HART® handheld device
■ Configuration
Measuring range 0.35 to 100 m (1.15 to 328.08 ft) • General CSAUS/C, CE, FM, C-TICK
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR460 C) 7 M L 5 4 2 6 - SITRANS LR460 C) 7 M L 5 4 2 6 -
4-wire, 24 GHz FMCW radar level transmitter with 0 7 7 7 0 - 777 0 4-wire, 24 GHz FMCW radar level transmitter with 0 7 7 7 0 - 77 7 0
extremely high signal-to-noise ratio and advanced extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of sol- signal processing for continuous monitoring of sol-
ids up to 100 m (328 ft). It is ideal for measurement ids up to 100 m (328 ft). It is ideal for measurement
in extreme dust. in extreme dust.
Order handheld programmer separately! Order handheld programmer separately!
Process connection Instruction manual
Universal, flat faced, 0.5 bar (7.25 psi) maximum English C) 7ML1998-5JM02
with integral Easy Aimer ball German C) 7ML1998-5JM32
3" (80 mm) A Multi-language Quick Start manual C) 7ML1998-5QW82
4" (100 mm) B This device is shipped with the Siemens Milltronics
6" (150 mm) C manual CD containing the complete ATEX Quick
Start and instruction manual library.
Antenna
3” horn antenna, fits 80 mm (3”) nozzles A Accessories
3" horn antenna, fits 80 mm (3") nozzles with B Handheld programmer, Infra-red, Intrinsically Safe, C) 7ML5830-2AJ
100 mm extension EEx ia
3" horn antenna, fits 80 mm (3") nozzles with C Dust cap, PTFE, for 3”/80 mm horn 7ML1930-1BL
200 mm extension Dust cap, PTFE, for 4”/100 mm horn 7ML1930-1BM
3" horn antenna, fits 80 mm (3") nozzles with D
5
HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
500 mm extension1) SIMATIC PDM)
3" horn antenna, fits 80 mm (3") nozzles with E HART modem/USB (for use with a PC and D) 7MF4997-1DB
1000 mm extension1) SIMATIC PDM)
4" horn antenna, fits 100 mm (4") nozzles F One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
+80 °C (-40 to +176 °F) (available for HART only -
4" horn antenna, fits 100 mm (4") nozzles with G two cable glands required)
100 mm extension
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
4" horn antenna, fits 100 mm (4") nozzles with H +80 °C (-40 to +176 °F) with integrated shield con-
200 mm extension nection (available for PROFIBUS PA)
4" horn antenna, fits 100 mm (4") nozzles with J 1)
500 mm extension1) Available with Purge option 0 only
4" horn antenna, fits 100 mm (4") nozzles with K C) Subject to export regulations AL: N, ECCN: EAR99
1000 mm extension1) D) Subject to export regulations AL: N, ECCN: EAR99H
Purge (self-cleaning) connection
No purge connection 0
Purge connection 1
■ Selection and Ordering data Order No.
Output/Communication
SITRANS LR460 Spare parts (7ML5426)
4 to 20 mA, HART® 0
PROFIBUS PA 1 100 mm (4”) horn extension kit, no A5E01087872
purge
Power supply/cable inlet
100 to 230 V AC 200 mm (8”) horn extension kit, no A5E01091262
purge
• 2 x M20x1.5 A
• 2 x ½“ NPT B 500 mm (16”) horn extension kit, no A5E01091263
purge
24 V DC
• 2 x M20x1.5 C 1000 mm (32”) horn extension kit, no A5E01091264
purge
• 2 x ½“ NPT D
Approvals
General Purpose, CSAUS/C, Industry Canada, FCC, A
CE and R&TTE, C-TICK
CSA/FM Class II, Div. 1, Groups E, F, and G, B
Class III
ATEX II 1/2 D T6, CE, R&TTE C
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Manufacturer’s test certificate M to DIN 55350, C11
Part 18 and to ISO 9000
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
■ Dimensional drawings
■ Schematics
■ Overview ■ Configuration
Mounting on a nozzle
length
dia.
Coaxial Probe Coaxial HT/HP Probe Coaxial HP Probe Coaxial Overfill/Flooded Cage
(7ML1301-1) (7ML1301-2) (7ML1301-3) Probe (7ML1301-4)
Recommended General purpose: clean, Clean, high temperature/high Clean, high pressure liquids Overfill, temperatures to
applications: low viscosity liquids < pressure liquids > +200 °C < +200 °C (+400 °F) +200 °C (+400 °F), clean, low
+150 °C (+300 °F) (+400 °F) viscosity liquids
Not recommended Coating and buildup, foam Coating and buildup, foam, Coating and buildup, foam, Coating and buildup, foam
for: steam steam
Materials/Wetted 316 L SS, TFE, Viton® GFLT 316L SS, Alumina, Borosili- 316L SS, TFE, Borosilicate, 316L SS, TFE, Viton GFLT
parts cate, Inconel X750 Inconel X750
Optional Hastelloy® C, Monel® Hastelloy C, Monel Hastelloy C, Monel Hastelloy C, Monel
Process Seal Viton GFLT O-ring Borosilicate Borosilicate Viton GFLT O-Ring
Rod/Tube Diameter: ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod
Standard ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube
Enlarged ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod
ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube
Process Connection
Thread:
Standard ¾” NPT [(Taper), ¾” NPT [(Taper), ANSI/ASME ¾” NPT [(Taper), ANSI/ASME ¾” NPT [(Taper), ANSI/ASME
5
Enlarged ANSI/ASME B1.20.1], B1.20.1], G 1” [(BSPP), EN B1.20.1], G 1” [(BSPP), EN B1.20.1], G 1” [(BSPP), EN ISO
G 1” [(BSPP), EN ISO 228- ISO 228-1] ISO 228-1] 228-1]
1] 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME
2” NPT [(Taper), B1.20.1] B1.20.1] B1.20.1]
ANSI/ASME B1.20.1]
Flange ANSI (DIN):
Standard 1 to 4” (DN25 to 100) 1 to 4” (DN25 to 100) 1 to 4” (DN25 to 100) 1 to 4” (DN25 to 100)
Enlarged 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100)
Length 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”)
Transition Zone: 25 mm (1”) @ dk = 1.4 none 25 mm (1”) @ dk = 1.4 none
Top 150 mm (6”) @ dk = 80 150 mm (6”) @ dk = 80
Transition Zone: 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4
Bottom 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80
Process temperature +150 °C @ 27 bar g +427 °C @ 133 bar g +200 °C @ 379 bar g +200 °C @ 18 bar g
maximum (+300 °F @ 400 psi g) (+800 °F @ 2000 psi g) (+400 °F @ 5500 psi g) (+400 °F @ 270 psi g)
Process temperature -40 °C @ 70 bar g -195 °C @ 430 bar g -195 °C @ 430 bar g -40 °C @ 70 bar g
minimum (-40 °F @ 1000 psi g) (-320 °F @ 6250 psi g) (-320 °F @ 6250 psi g) (-40 °F @ 1000 psi g)
Process pressure 70 bar g @ +20 °C 431 bar @ +20 °C 431 bar @ +20 °C 70 bar g @ +20 °C
maximum (1000 psi g @ +70 °F) (6250 psi g @ +70 °F) (6250 psi g @ +70 °F) (1000 psi g @ +70 °F)
Process pressure Yes, not hermetic1) Yes, hermetic Yes, hermetic Yes, not hermetic
minimum/vacuum (<10-8 cc/sec @ 1 atmo- (<10-8 cc/sec @ 1 atmo-
service sphere) sphere)
Dielectric range 1.4 to 100 1.4 to 100 1.4 to 100 1.4 to 100
Maximum viscosity
(cP)
Standard 500 500 500 500
Enlarged 1500 1500 1500 1500
Coating/buildup No No No No
Foam No No No No
Corrosives Yes Yes Yes Yes
Sanitary No No No No
Overfill No Yes No Yes
1)
Not hermetic: sealing by means of O-ring. Hermetic: sealing by means of borosilicate glass window.
®Viton is a registered trademark of DuPont Dow Elastomers.
®Hastelloy is a registered trademark of Haynes International.
®Kalrez is a registered trademark of DuPont Dow Elastomers.
®Monel is a registered trademark of Special Metals Corporation.
Coaxial HT/HP Steam Coaxial Interface Probe Single Rigid Rod Probe Single Rigid Rod Probe, PFA
Probe (7ML1301-5) (7ML1301-6) (7ML1303-1), Single Rigid rod insulation (7ML1303-1J)
Rod HT/HP Probe (7ML1303-
2)
Recommended Hot water (steam) (external Temperatures to +200 °C Coating and buildup, foam Excessive coating and buildup,
applications: chamber is required for use (+400 °F); clean, low-viscosity foam
in boilers) liquids
Not recommended General purpose, coating Coating and buildup, foam Low dielectric media Low dielectric media (dK < 10)
for: and buildup, foam (dK < 10)1)
Materials/Wetted 316 L SS, PEEK, Aegis 316L SS, TFE, Viton GFLT 316L SS, TFE, Viton GFLT 316L SS, PFA, Viton GFLT
parts PF128
Optional N/A Hastelloy C, Monel Hastelloy C, Monel N/A
Process seal Aegis PF128 O-ring, PEEK Viton GFLT O-ring 7ML1303-1: Viton GFLT O-ring Viton GFLT O-ring
7ML1303-2: Aegis PF128
Rod/Tube Diameter: ø 12 mm (0.5”) rod
Standard ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 12 mm (0.5”) rod ø 16 mm (0.625”) insulation
ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube
Enlarged N/A ø 15 mm (0.63”) rod N/A N/A
ø 45 mm (1.75”) tube
5 Process Connection
Thread:
Standard ¾” NPT [(Taper), ¾” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME
Enlarged ANSI/ASME B1.20.1], B1.20.1], G 1” [(BSPP), EN B1.20.1], G 2” [(BSPP), EN B1.20.1], G 2” [(BSPP), EN ISO
G 1” [(BSPP), EN ISO 228- ISO 228-1] ISO 228-1] 228-1]
1] 2” NPT [(Taper), ANSI/ASME N/A N/A
N/A B1.20.1]
Flange ANSI (DIN):
Standard 1 to 4” (DN25 to 100) 1 to 4” (DN25 to 100) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100)
Enlarged N/A 2 to 4” (DN50 to 100) N/A N/A
Length 60 to 455 cm (24 to 180”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”)
Transition Zone: 25 mm (1”) @ dk ≥ 10 none Blocking distance: 12 to 91 cm Blocking distance: 12 to 91 cm
Top (4.8 to 36”), probe length (4.8 to 36”), probe length
dependent dependent
Transition Zone: 25 mm (1”) @ dk ≥ 10 150 mm (6”) @ dk = 1.4 25 mm (1”) @ dk >10 25 mm (1”) @ dk >10
Bottom 25 mm (1”) @ dk = 80
Process temperature +343 °C @ 165 bar g +200 °C @ 18 bar g 7ML1303-1: +150 °C @ +150 °C @ 27 bar g
maximum (+650 °F @ 2400 psi g) (+400 °F @ 270 psi g) 27 bar g (+300 °F @ 400 psi g) (+300 °F @ 400 psi g)
(saturated steam) 7ML1303-2: +316 °C @
165 bar g
(+605 °F@2400 psi g)
Process temperature -40 °C @ 207 bar g -40 °C @ 70 bar g -40 °C @ 70 bar g -40 °C @ 50 bar g
minimum (-40 °F @ 3000 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 750 psi g)
Process pressure 165 bar @ +343 °C 70 bar @ +20 °C 7ML1303-1: 70 bar @ +20 °C 70 bar @ +20 °C
maximum (2400 psi g @ 650 °F) (1000 psi g @ +70°F) (1000 psi g @ +70 °F) (1000 psi g @ +70 °F)
7ML1303-1: 207 bar @ +20 °C
(3000 psi g @ +70 °F)
Process pressure Yes, not hermetic Yes, not hermetic Not suitable Not suitable
minimum/vacuum
service
Dielectric range 10 to 100 Upper Liquid Layer 1.4 to 5 1.9 to 1001) 1.9 to 1001)
Interface Liquid Layer 15 to
100
Maximum viscosity
(cP)
Standard 500 500 10 000 (consult factory if severe agitation/turbulence
Enlarged N/A 1500
Coating/buildup No No Yes, maximum error 10% of coated length;% error related to
dielectric of media, thickness of coating and coated probe
length above media
Foam No No Yes Yes
Corrosives Yes Yes Yes Yes
Sanitary No No No No
Overfill Yes Yes No No
1) With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6”) of metal tank wall or in chamber/bridle.
Single Rigid Rod Probe, Single Rigid Rod Probe, PFA Single Flexible Rod Probe Single Flexible Rod Probe for
Sanitary (7ML1303-1D) faced flange(7ML1303-1E) (7ML1304-1) Bulk Solids (7ML1304-2)
Recommended Applications demanding Extreme corrosives, coat- Coating and buildup, foam; Bulk solids applications (pow-
applications: sanitary specifications ing/buildup, foam lengths > 6 m (20 ft) headroom ders, grain, dust) 3000 lb pull
down force
Not recommended Low dielectric media Low dielectric media Low dielectric media (dK < 10) Solids with dK > 4
for: (dK < 10)1) (dK < 10)1)
Materials/Wetted 316 L SS, TFE, <20 Ra finish All PFA - wetted surfaces 316L SS, TFE, Viton GFLT 316L SS, TFE, Viton GFLT
parts
Optional Hastelloy C, Monel, N/A N/A N/A
AL6XN SS
Process seal 316L SS, TFE, Viton GFLT PFA, no o-ring Viton GFLT O-ring Sealant
O-ring
Rod/Tube Diameter ø 12 mm (0.5”) rod ø 12 mm (0.5”) rod ø 5 mm (0.188”) cable ø 6 mm (0.25”) cable
ø 16 mm (0.625”) insulation
Process Conn. Thread N/A N/A 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME
B1.20.1], G 2” [(BSPP), EN B1.20.1], G 2” [(BSPP), EN ISO
ISO 228-1] 228-1]
Flange ANSI (DIN) 38 to 100 mm (1.5 to 4”) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100)
Length
Triclover-style 16 amp fitting
60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 2 to 22 meters (6 to 75 ft) 2 to 22 meters (6 to 75 ft)
5
Transition Zone: Blocking distance: 0 to Blocking distance: 12 to 91 cm Blocking distance: 12 to 91 cm Blocking distance: 12 to 91 cm
Top 91 cm (0 to 36”), probe (4.8 to 36”), probe length (4.8 to 36”), probe length (4.8 to 36”), probe length
length dependent dependent dependent dependent
Transition Zone: 25 mm (1”) @ dk >10 305 mm (12”) 305 mm (12”)
Bottom 25 mm (1”) @ dk >10
Process temperature +150 °C @ 5.1 bar g +150 °C @ 27 bar g +150 °C @ 27 bar g +66 °C (+150 °F)
maximum (+300 °F @ 75 psi g) (+300 °F @ 400 psi g) (+300 °F @ 400 psi g)
Process temperature 0 °C at 5.1 bar g -40 °C @ 13.7 bar g -40 °C @ 70 bar g -40 °C @ 3.4 bar g
minimum 32 °F at 75 psi g (-40 °F @ 200 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 50 psi g)
Process pressure 5.1 bar g @ +150 °C 70 bar @ +20 °C 70 bar @ +20 °C 3.4 bar g (50 psi g)
maximum (75 psi g @ +300 °F) (1000 psi g @ +70°F) (1000 psi g @ +70 °F)
Process pressure Not suitable for vacuum applications
minimum/vacuum
service
Dielectric range 1.9 to 1001) 1.9 to 100 10 to 1001) 4 to 100
Maximum viscosity 10 000 (consult factory if severe agitation/turbulence N/A
(cP)
Coating/buildup Yes, maximum error 10% of coated length;% error related to dielectric of media, thickness of coating and coated probe
length above media
Foam Yes Yes Yes Yes
Corrosives No Yes No No
Sanitary Yes No No No
Overfill No No No No
1) With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6”) of metal tank wall or in chamber/bridle.
Twin Rod Probe Flexible Twin Rod Probe Flexible Light Duty Bulk Solids Probe
(7ML1302-1) (7ML1302-3) (7ML1302-2)
Recommended applications: General purpose, foam, minor Low dielectric media (2.0 to 10) with Light bulk solids applications (powders,
film coating lengths > 6 m (20 ft) grains, dust), 3000 lbs pull-down force
Not recommended for: Media bridging between rods Dielectric > 10: media bridging on flexible Media bridging flexible elements
or building up on spacers elements
Materials/Wetted parts 316L SS, TFE, Viton GFLT 316L SS, FEP, Viton GFLT 316L SS, TFE, Viton GFLT
Optional Hastelloy C, Monel N/A N/A
Process seal Viton GFLT O-ring Viton GFLT O-ring Sealant
Rod/Tube Diameter Two, ø 12 mm (0.5”) rod; Two, ø 6 mm (0.25”) cables; 22 mm Two, ø 6 mm (0.25”) cables; 22 mm
22 mm (0.875”) CL to CL (0.875”) CL to CL (0.875”) CL to CL
Process Conn. Thread 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME B1.20.1], 2” NPT [(Taper), ANSI/ASME B1.20.1],
B1.20.1], G 2” [(BSPP), EN G 2” [(BSPP), EN ISO 228-1] G 2” [(BSPP), EN ISO 228-1]
ISO 228-1]
Flange ANSI (DIN) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100) 2 to 4” (DN50 to 100)
Length 60 to 610 cm (24 to 240”) 2 to 22 m (6 to 75 ft) 2 to 22 m (6 to 75 ft)
Transition Zone1):
Top 150 mm (6”) @ dK > 1.9 150 mm (6”) @ dK > 1.9 150 mm (6”) @ dK > 1.9
Blocking distance: none Blocking distance: 12 to 50 cm (4.8 to 20”) Blocking distance: 12 to 50 cm (4.8 to 20”)
5 Transition Zone:
Bottom
150 mm (6”) @ dK = 1.9
25 mm (1”) @ dK = 80
305 mm (12”) 305 mm (12”)
Process temperature max.2) +200 °C @ 19 bar g (+400 °F @ 275 psi g) +66 °C (+ 150 °F)
Process temperature min. -40 °C @ 70 bar g (-40 °F @ 100 psi g) -40 °C @ 3.4 bar g (-40 °F @ 50 psi g)
Process pressure max. 70 bar g @ +20 °C (1000 psi g @ +70 °F) 3.4 bar g (50 psi g)
Process pressure Yes, not hermetic Not suitable
min./vacuum service
Dielectric range 1.9 to 100 1.9 to 100 1.9 to 100
Maximum viscosity (cP) 1500 1500 Not suitable
Coating/buildup Yes, maximum error 3% of coated length with conductive media
Bridging not recommended.3)
Foam Yes Yes Yes
Corrosives Yes No Yes
Sanitary No No No
Overfill No No No
1)
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone.
2)
Refer to Ambient Temperature vs Process Temperature graphs in instruction manual.
3)
Bridging is defined as continuous accumulation of material between the probe elements.
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 C) 7 M L 1 3 0 0 - SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 -
A guided wave radar transmitter for short and 77 7 1 7 - 77 A 0 SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 777 0
medium range level, level/interface, and volume standard applications. Coaxial probes yield robust
measurement of liquids and solids, including high signal strength even in extremely low dielectric
temperature and pressure applications, and steam. applications (dK 1.4 to 100).
Power Model
24 V DC, 2-wire 1 Coaxial 1
Signal Output Coaxial, High Temperature/High Pressure1) 2
4 to 20 mA HART A Coaxial, High Pressure1) 3
Options Coaxial, Overfill/Flooded Cage 4
Standard (SIL-1 Approved) A Coaxial, High Temperature/High Pressure, Steam2) 5
and 3)
SIL 2 (FMEDA) approved B
Coaxial, Interface1) 6
Enclosure/lid
Aluminum 1 Material of Construction
Aluminum with glass window 2 316/316L stainless steel probe and process con- A
nection
Cable inlet Hastelloy C probe and process connection B
2 x ½” NPT, IP65 0 Monel probe and process connection C
2 x M20x1.5, IP651) 1
316/316L SS probe and process connection, ASME D
Approvals
General Purpose and Intrinsically Safe (FM/CSA A
B31.1 specifications4)
Enlarged Coaxial, 316/316L stainless steel probe
and process connection5)
E 5
Class I, Div. 1, Groups A, B, C, and D; Class II,
Div. 1, Groups E, F, and G T4, Class III); Non-incen- Enlarged Coaxial, Hastelloy C probe and process F
dive (CSA Class I, Div. 2, Groups A, B, C, D, Class connection5)
II, Div. 2, Groups E, F, G; FM Class I, Div. 2, Groups
A, B, C, D, Class II, Div. 2, Groups F, G) Enlarged Coaxial, Monel probe and process G
connection5)
Explosion Proof (FM/CSA Class I, Div. 1, Groups B, B 316/316L stainless steel probe and process con- H
C, and D; Class II, Div. 1, Groups E, F, and G, T4; nection with PEEK HT spacers6)
Class III); Non-incendive (CSA Class I, Div. 2, 316/316L stainless steel probe and process con- J
Groups A, B, C, D, Class II, Div. 2, Groups E, F, G; nection with Teflon® spacers6)
FM Class I, Div. 2, Groups A, B, C, D, Class II, Div.
2, Groups F, G) Probe Insertion Length
General Purpose and Intrinsically Safe (ATEX II 1G C Add order code Y01 and plain text: “Insertion
EEx ia IIC T4) length ... cm”
Explosion Proof (ATEX II 1/2 GD EEx d [ia] IIC T6) D Model option 1,4 and Material of Construction A1
option A, E: 60 to 100 cm (23.6 to 39.4")
Non-sparking (ATEX II 3G EEx nA II/EEx nA (nL) IIC E
T4 to T6) Model option 1,4 and Material of Construction A2
option A, E: 101 to 200 cm (39.8 to 78.7")
Instruction manual Model option 1,4 and Material of Construction A3
English C) 7ML1998-5KA01 option A, E: 201 to 300 cm (79.1 to 118.1")
German C) 7ML1998-5KA31
Model option 1,4 and Material of Construction A4
Multi-language Quick Start manual C) 7ML1998-5XG81 option A, E: 301 to 400 cm (118.5 to 157.5")
This device is shipped with the Siemens Milltronics Model option 1,4 and Material of Construction A5
manual CD containing the complete instruction option A, E: 401 to 500 cm (157.9 to 196.9")
manual library. Model option 1,4 and Material of Construction A6
option A,E: 501 to 610 cm (197.2 to 240.2")
1)
Available with Approval option C, D, and E only. Add order code Y01 and plain text: “Insertion
length ... cm”
Model options 3, 6 with Material of Construction B1
option A: 60 to 100 cm (23.6 to 39.4")
Model options 3, 6 with Material of Construction B2
option A: 101 to 200 cm (39.8 to 78.7")
Model options 3, 6 with Material of Construction B3
option A: 201 to 300 cm (79.1 to 118.1")
Model options 3, 6 with Material of Construction B4
option A: 301 to 400 cm (118.5 to 157.5")
Model options 3, 6 with Material of Construction B5
option A: 401 to 500 cm (157.9 to 196.9")
Model options 3, 6 with Material of Construction B6
option A: 501 to 610 cm (197.2 to 240.2")
Add order code Y01 and plain text: “Insertion
length ... cm”
Model options 3, 6 with Material of Construction C1
option E: 60 to 100 cm (23.6 to 39.4")
Model options 3, 6 with Material of Construction C2
option E: 101 to 200 cm (39.8 to 78.7")
Model options 3, 6 with Material of Construction C3
option E: 201 to 300 cm (79.1 to 118.1")
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 - SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 -
SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 777 0 SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 777 0
standard applications. Coaxial probes yield robust standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric signal strength even in extremely low dielectric
applications (dK 1.4 to 100). applications (dK 1.4 to 100).
Model options 3, 6 with Material of Construction C4 2" 150 lb ANSI raised face flange DA
option E: 301 to 400 cm (118.5 to 157.5") 2" 300 lb ANSI raised face flange DB
Model options 3, 6 with Material of Construction C5 2" 600 lb ANSI raised face flange8) DC
option E: 401 to 500 cm (157.9 to 196.9") 2" 900/1500 lb ANSI raised face flange8) DD
Model options 3, 6 with Material of Construction C6 2" 2500 lb ANSI raised face flange8) DE
option E: 501 to 610 cm (197.2 to 240.2")
2" 600 lb ANSI ring joint flange8) DF
Add order code Y01 and plain text: “Insertion
length ... cm” 2" 900/1500 lb ANSI ring joint flange8) DG
Model options 2, 5 with Material of Construction D1 2" 2500 lb ANSI ring joint flange8) DH
options A, D, E, H, J: 60 to 100 cm (23.6 to 39.4") 2" 150 lb ANSI raised face carbon steel flange with DJ
Model options 2, 5 with Material of Construction D2 top hat
options A, D, E, H, J: 101 to 200 cm (39.8 to 78.7") 2" 300/600 lb ANSI raised face carbon steel flange DK
Model options 2, 5 with Material of Construction D3 with top hat
options A, D, E, H, J: 201 to 300 cm (79.1 to 118.1")
3" 150 lb ANSI raised face flange EA
Model options 2, 5 with Material of Construction D4 3" 300 lb ANSI raised face flange EB
5
options A, D, E, H, J: 301 to 400 cm (118.5 to 3" 600 lb ANSI raised face flange8) EC
157.5")
Model options 2, 5 with Material of Construction D5 3" 900 lb ANSI raised face flange8) ED
options A, D, E, H, J: 401 to 500 cm (157.9 to 3" 1500 lb ANSI raised face flange8) EE
196.9") 3" 2500 lb ANSI raised face flange 8) EF
Model options 2, 5 with Material of Construction D6
options A, D, E, H, J: 501 to 610 cm (197.2 to 3" 600 lb ANSI ring joint flange8) EG
240.2") 3" 900 lb ANSI ring joint flange8) EH
Note: For orders of 10 or more, please consult fac- 3" 1500 lb ANSI ring joint flange8) EJ
tory 3" 2500 lb ANSI ring joint flange8) EK
O-Rings 3" 150 lb ANSI raised face carbon steel flange with EL
Viton 1 1 top hat
EPDM (Ethylene Propylene) 1 2 3" 300/600 lb ANSI raised face carbon steel flange EM
Kalrez 4079 1 3 with top hat
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 - SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 -
SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 777 0 SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust cations where coating and buildup are possible.
signal strength even in extremely low dielectric Used in application with dielectric constant ≥1.9.
applications (dK 1.4 to 100).
Model
DN 80 PN 16 DIN 2527 form B flange KA Twin rod 1
DN 80 PN 25/40 DIN 2527 form B flange KB Flexible twin rod bulk solids probe1) 2
DN 80 PN 64 DIN 2527 form E flange8) KC Flexible twin rod probe1) 3
DN 80 PN 100 DIN 2527 form E flange8) KD Material of Construction
DN 80 PN 160 DIN 2527 form E flange8) KE 316/316L stainless steel probe and process con- A
DN 80 PN 250 DIN 2527 form E flange8) KF nection
DN 80 PN 320 DIN 2527 form E flange8) KG Hastelloy C probe and process connection B
DN 80 PN 400 DIN 2527 form E flange8) KH Monel probe and process connection C
5
LF
3" 150 lb ANSI raised face flange B2
DN 100 PN 320 DIN 2527 form E flange8) LG
DN 100 PN 400 DIN 2527 form E flange8) LH 3" 300 lb ANSI raised face flange C1
4" 150 lb ANSI raised face flange C2
Fisher torque tube flange, carbon steel (249B) MA
Fisher torque tube flange, 316 stainless steel MB 4" 300 lb ANSI raised face flange D1
(249C) DN 50 PN 16 DIN 2527 form B flange D2
Masoneilan torque tube flange, carbon steel MC DN 50 PN 25/40 DIN 2527 form B flange E1
Masoneilan torque tube flange, 316 stainless steel MD Fisher Torque Tube flange, 316SS (249C) F1
Masoneilan torque tube flange, carbon steel with ME Masoneilan Torque Tube flange, 316SS G1
top hat Carbon Steel
316 stainless steel with top hat MF 2" 150 lb ANSI raised face Carbon Steel flange with H1
top hat
Further designs Order code
2" 300 lb /600 lb ANSI raised face Carbon Steel H3
Please add “-Z” to Order No. and specify Order flange with top hat
code(s).
3" 150 lb ANSI raised face Carbon Steel flange with J1
Enter the total insertion length in plain text descrip- Y01 top hat
tion, max. 610 cm (240.2”) 3" 300 lb /600 lb ANSI raised face Carbon Steel J2
Instruction manual flange with top hat
English C) 7ML1998-5KA01 Fisher Torque Tube flange, Carbon Steel (249B) K1
German C) 7ML1998-5KA31 Fisher Torque Tube flange, Carbon steel with top K2
Multi-language Quick Start manual C) 7ML1998-5XG81 hat (249B)
This device is shipped with the Siemens Milltronics Masoneilan Torque Tube flange, Carbon Steel L1
manual CD containing the complete instruction Masoneilan Torque Tube flange, Carbon steel with L2
manual library. top hat
1)
Consult factory for these options in Hastelloy C or Monel. O-Ring
2)
Only offered in 316/316L. Viton 1 1
3) EPR (Ethylene Propylene Rubber) 1 2
Coaxial, High Temperature/High Pressure Steam Probe used with O-ring
type Aegis PF128. Kalrez 4079 1 3
4)
Available with model option 5 only HSN (NACE) 1 4
5) Buna-N 1 5
2" minimum Process Connection
6)
Used with HT/HP Probe only Neoprene 1 6
7)
Available with model option 2 and 3 only Chemraz 1 7
8) Polyurethane 1 8
Available with High Temperature/High Pressure and High Pressure probes
only.
Aegis PF 128 2 1
Kalrez 2035 2 2
Probe Insertion Length
Add order code Y01 and plain text: “Insertion
length ... cm”
Model option 1 and Material of Construction AA
option A: 60 to 100 cm (23.6 to 39.4")
Model option 1 and Material of Construction AB
option A: 101 to 200 cm (39.8 to 78.7")
Model option 1 and Material of Construction AC
option A: 201 to 300 cm (79.1 to 118.1")
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 - SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 -
SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0 SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0
cations where coating and buildup are possible. cations where coating and buildup are possible.
Used in application with dielectric constant ≥1.9. Used in application with dielectric constant ≥1.9.
Model option 1 and Material of Construction AD Model option 2,3 and Material of Construction ES
option A: 301 to 400 cm (118.5 to 157.5") option A: 17 meters (669.3")
Model option 1 and Material of Construction AE Model option 2,3 and Material of Construction ET
option A: 401 to 500 cm (157.9 to 196.9") option A: 18 meters (708.7")
Model option 1 and Material of Construction AF Model option 2,3 and Material of Construction EU
option A: 501 to 610 cm (197.2 to 240.2") option A: 19 meters (748.0")
Add order code Y01 and plain text: “Insertion Model option 2,3 and Material of Construction EV
length ... cm” option A: 20 meters (787.4")
Model option 1 and Material of Construction BA Model option 2,3 and Material of Construction EW
option B: 60 to 100 cm (23.6 to 39.4") option A: 21 meters (826.8")
Model option 1 and Material of Construction BB Model option 2,3 and Material of Construction EX
option B: 101 to 200 cm (39.8 to 78.7") option A: 22.5 meters (885.8")
Model option 1 and Material of Construction BC
option B: 201 to 300 cm (79.1 to 118.1") Further designs Order code
Model option 1 and Material of Construction BD Please add “-Z” to Order No. and specify Order
option B: 301 to 400 cm (118.5 to 157.5") code(s).
Model option 1 and Material of Construction BE Enter the total insertion length in plain text descrip- Y01
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 - SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 -
SITRANS LG200 single rod rigid probes are used in 77 7 7 7 - 777 0 SITRANS LG200 single rod rigid probes are used in 7 7 7 7 7 - 77 7 0
applications where coating and buildup are likely. applications where coating and buildup are likely.
Used in application with dielectric constant ≥10, or Used in application with dielectric constant ≥10, or
dk >1.9 when installed within 2 to 6" of a metal tank dk >1.9 when installed within 2 to 6" of a metal tank
wall or in cage or bridle. wall or in cage or bridle.
Model Chemraz 1 7
Single rod rigid probe 1 Polyurethane 1 8
High Temperature/High Pressure Single rod1) 2 Aegis PF 128 2 1
Material of Construction Kalrez 2035 2 2
316/316L stainless steel probe and process con- A None4) 2 3
nection Probe Insertion Length
Hastelloy C276 probe and process connection B Add order code Y01 and plain text: “Insertion
Monel probe and process connection C length ... cm”
316/316L stainless steel sanitary probe and pro- D Model option 1,2 and Material of Construction AA
cess connection option A: 60 to 100 cm (23.6 to 39.4")
PFA faced-flange and rod insulation, all PFA wetted E Model option 1,2 and Material of Construction AB
parts (316 SS rod) option A: 101 to 200 cm (39.8 to 78.7")
316 AL6XN stainless steel sanitary probe and pro- F Model option 1,2 and Material of Construction AC
cess connection option A: 201 to 300 cm (79.1 to 118.1")
Hastelloy C22 sanitary probe and process connec-
tion
G Model option 1,2 and Material of Construction
option A: 301 to 400 cm (118.5 to 157.5")
AD
5
Paint probe, 316/316L SS, ¾” process connection H Model option 1,2 and Material of Construction AE
or larger2) (72" max length) option A: 401 to 500 cm (157.9 to 196.9")
PFA rod insulation (316 SS rod and process con- J Model option 1,2 and Material of Construction AF
nection) option A: 501 to 610 cm (197.2 to 240.2")
Add order code Y01 and plain text: “Insertion
Process Connection (size/type) length ... cm”
316 Stainless steel Model option 1 and Material of Construction BA
¾” NPT [(Taper), ANSI/ASME B1.20.1] A0 option D: 60 to 100 cm (23.6 to 39.4")
1½” Tri-Clover 16 amp sanitary fitting A1 Model option 1 and Material of Construction BB
2" NPT [(Taper), ANSI/ASME B1.20.1] A2 option D: 101 to 200 cm (39.8 to 78.7")
G 2" [(BSPP), EN ISO 228-1] A3 Model option 1 and Material of Construction BC
option D: 201 to 300 cm (79.1 to 118.1")
2" 150 lb ANSI raised face flange A4
2" 300 lb ANSI raised face flange A5 Model option 1 and Material of Construction BD
2" Tri-Clover 16 amp sanitary fitting A6 option D: 301 to 400 cm (118.5 to 157.5")
Model option 1 and Material of Construction BE
3" 150 lb ANSI raised face flange B1 option D: 401 to 500 cm (157.9 to 196.9")
3" 300 lb ANSI raised face flange B2 Model option 1 and Material of Construction BF
3" Tri-Clover 16 amp sanitary fitting B3 option D: 501 to 610 cm (197.2 to 240.2")
4" 150 lb ANSI raised face flange C1 Add order code Y01 and plain text: “Insertion
length ... cm”
4" 300 lb ANSI raised face flange C2
Model option 1 and Material of Construction CA
4" Tri-Clover 16 amp sanitary fitting C3 option F: 60 to 100 cm (23.6 to 39.4")
DN 50, PN 16, DIN 2527 form B flange D1 Model option 1 and Material of Construction CB
DN 50, PN 25/40, DIN 2527 form B flange D2 option F: 101 to 200 cm (39.8 to 78.7")
AL6XN Model option 1 and Material of Construction CC
1½” Tri-Clover 16 amp sanitary fitting E1 option F: 201 to 300 cm (79.1 to 118.1")
2" Tri-Clover 16 amp sanitary fitting E2 Model option 1 and Material of Construction CD
option F: 301 to 400 cm (118.5 to 157.5")
3" Tri-Clover 16 amp sanitary fitting F1
Model option 1 and Material of Construction CE
4" Tri-Clover 16 amp sanitary fitting G1 option F: 401 to 500 cm (157.9 to 196.9")
PFA Coated 316 stainless steel flange3) Model option 1 and Material of Construction CF
2" 150 lb ANSI raised face flange H1 option F: 501 to 610 cm (197.2 to 240.2")
2" 300 lb ANSI raised face flange H2 Add order code Y01 and plain text: “Insertion
3" 150 lb ANSI raised face flange J1 length ... cm”
3" 300 lb ANSI raised face flange’ J2 Model option 1 and Material of Construction DA
option E: 60 to 100 cm (23.6 to 39.4")
4" 150 lb ANSI raised face flange K1 Model option 1 and Material of Construction DB
4" 300 lb ANSI raised face flange K2 option E: 101 to 200 cm (39.8 to 78.7")
DN 50, PN 16, DIN 2527 form B flange L1 Model option 1 and Material of Construction DC
option E: 201 to 300 cm (79.1 to 118.1")
DN 50, PN 25/40, DIN 2527 form B flange L2
Model option 1 and Material of Construction DD
O-Ring option E: 301 to 400 cm (118.5 to 157.5")
Viton 1 1 Model option 1 and Material of Construction DE
EPR (Ethylene Propylene Rubber) 1 2 option E: 401 to 500 cm (157.9 to 196.9")
Kalrez 4079 1 3 Model option 1 and Material of Construction DF
HSN (NACE) 1 4 option E: 501 to 610 cm (197.2 to 240.2")
Buna-N 1 5
Neoprene 1 6
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 - SITRANS LG200 Single Rod Flexible Probes C) 7 M L 1 3 0 4 -
SITRANS LG200 single rod rigid probes are used in 77 7 7 7 - 777 0 SITRANS LG200 single rod flexible probes are 7 7 7 7 7 - 77 7 0
applications where coating and buildup are likely. used in applications where coating and buildup are
Used in application with dielectric constant ≥10, or possible. Used in application with dielectric con-
dk >1.9 when installed within 2 to 6" of a metal tank stant ≥10 or dk >1.9 when installed within 2 to 6” of
wall or in cage or bridle. a metal tank wall or in cage or bridle.
Add order code Y01 and plain text: “Insertion Model
length ... cm” Single rod flexible probe 1
Model option 1 and Material of Construction EA Single rod bulk solids flexible probe 2
option J: 60 to 100 cm (23.6 to 39.4")
Material of Construction
Model option 1 and Material of Construction EB
option J: 101 to 200 cm (39.8 to 78.7") 316/316L stainless steel probe and process con- A
nection
Model option 1 and Material of Construction EC
option J: 201 to 300 cm (79.1 to 118.1") Process Connection (size/type)
316/316L (1.4401/1.4404)
Model option 1 and Material of Construction ED
option J: 301 to 400 cm (118.5 to 157.5") 2" NPT [(Taper), ANSI/ASME B1.20.1] A0
G 2" [(BSPP), EN ISO 228-1] A1
Model option 1 and Material of Construction EE
option J: 401 to 500 cm (157.9 to 196.9") 2" 150 lb ANSI raised face flange A2
Model option 1 and Material of Construction EF 2" 300 lb ANSI raised face flange A3
option J: 501 to 610 cm (197.2 to 240.2") 3" 150 lb ANSI raised face flange B1
Further designs Order code 3" 300 lb ANSI raised face flange B2
Enter the total insertion length in plain text descrip- Y01 DN 50 PN 16 DIN 2527 form B flange D1
tion, max. 610 cm (240.2”) DN 50 PN 25/40 DIN 2527 form B flange D2
■ Dimensional drawings
■ Schematics
SITRANS LG200 General Purpose Wiring
SITRANS LG200
■ Overview ■ Configuration
■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
• Highly accurate and reliable PFA-lined probes
• Integrated local LCD display
• 2-wire (4 to 20 mA) current loop design
• Current signalling according to NAMUR NE 43
• Push-button calibration and programming SITRANS LC300 installation
■ Application
SITRANS LC300 is a 2-wire level measurement instrument com-
bining a sophisticated, yet easy-to-adjust microprocessor with
field-proven probes. It is available in two versions: rod and ca-
ble.
SITRANS LC300 has a stainless steel process connection with
PFA-lined probe. Materials with low or high dielectric properties
are accurately measured and patented Active-Shield technol-
ogy helps in ignoring the effects of buildup near vessel nozzle.
• Key Applications: Conductive and non-conductive media in-
cluding liquids and solids in standard industrial processes
and bulk solids applications involving dust or chemical pro-
cesses involving vapour
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC300, threaded 7ML 5 6 2 5 - SITRANS LC300, threaded 7ML 5 6 2 5 -
An inverse frequency shift capacitance continuous 77 7 77 - 77 A 7 An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Version Enclosure
(threaded lengths include process thread) Aluminum, epoxy-coated
Rod, 19 mm (0.75”) diameter, PFA insulated Cable entry 2 x ½” NPT, IP65 0
Add order code Y01 and plain text: “Insertion Cable entry 2 x M20x1.5, IP65 1
length ... mm”
- 300 to 1000 mm (11.81 to 39.37”) 0A Cable entry 2 x ½” NPT, IP68 2
- 1001 to 2000 mm (39.41 to 78.74”) 1A Cable entry 2 x M20x1.5, IP68 3
- 2001 to 3000 mm (78.78 to 118.11”)4) 2A Thermal isolator/remote version
- 3001 to 4000 mm (118.15 to 157.48”)4) 3A None A
- 4001 to 5000 mm (157.52 to 196.85”)4) 4A With thermal isolator B
Rod, 19 mm (0.75”) diameter, PFA insulated with With mounting eye3) C
35 mm (1.38”) diameter stilling well With thermal isolator and mounting eye3) D
Add order code Y01 and plain text: “Insertion
length ... mm” Electronic transmitter
- 300 to 1000 mm (11.81 to 39.37”)1) 0B 3300 pF range 1
- 1001 to 2000 mm (39.41 to 78.74”)1) 1B Further designs Order code
- 2001 to 3000 mm (78.78 to 118.11”)1) and 4) 2B
Please add “-Z” to Order No. and specify Order
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K0 M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC 7ML1830-1JD
and EEx e II, fits cable diameter 10.5 to 15.9 mm
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B L0 (0.41 to 0.63”), under armour cable diameter 6.1 to
0202]2) 11.5 mm (0.24 to 0.45”), -60 to 130 °C (-76 to
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B M0 +266 °F), IP68 (Explosion Proof)
0202]2) Electronic transmitter kit (includes transmitter and 7ML1830-1KN
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B N0 driver)
0202] 1) For process connections 1½” and larger
Approvals 2) Available for rod versions only
General purpose 1 3) Available for PFA insulated cable versions 0E to 4E only
CSA and FM Class II and III, Div. 1, Groups E, F, G 2 4)
T4; ATEX II 1/2 D T100 °C Custom shipping methods required. Contact factory for more details.
ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3
CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC300, welded flange 7ML 5 6 2 6 - SITRANS LC300, welded flange 7ML 5 6 2 6 -
An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7 An inverse frequency shift capacitance continuous 77 7 77 - 77 A 7
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Version DN 100, PN 403) N6
(lengths from flange face) (Note: Flange bolting patterns and facings dimen-
Rod, PFA insulated sionally correspond to the applicable ASME B16.5,
Add order code Y01 and plain text: “Insertion or EN 1092-1 standard.)
length ... mm” Approvals
- 300 to 1000 mm (11.81 to 39.37”) 0A General purpose 1
- 1001 to 2000 mm (39.41 to 78.74”) 1A CSA and FM Class II and III, Div. 1, Groups E, F, G 2
- 2001 to 3000 mm (78.78 to 118.11”)3) 2A T4; ATEX II 1/2 D T100 °C
- 3001 to 4000 mm 118.15 to 157.48”)3) 3A ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3
- 4001 to 5000 mm (157.52 to 196.85”)3) 4A CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4
Rod, PFA insulated with stilling well
Add order code Y01 and plain text: “Insertion Enclosure
length ... mm” Aluminum, epoxy-coated
- 300 to 1000 mm (11.81 to 39.37”)1) 0B • Cable entry 2 x ½” NPT, IP65 0
- 1001 to 2000 mm (39.41 to 78.74”)1) 1B • Cable entry 2 x M20x1.5, IP65 1
- 2001 to 3000 mm (78.78 to 118.11”)1) and 3) 2B • Cable entry 2 x ½” NPT, IP68 2
- 3001 to 4000 mm (118.15 to 157.48”)1) and 3) 3B • Cable entry 2 x M20x1.5, IP68 3
- 4001 to 5000 mm (157.52 to 196.85”)1) and 3) 4B Thermal isolator/remote version
5
Cable, PFA insulated, weighted None A
Add order code Y01 and plain text: “Insertion With thermal isolator B
length ... mm”
- 1000 to 2000 mm (39.37 to 78.74”)1) 0E With mounting eye2) C
- 2001 to 4000 mm (78.78 to 157.48”)1) 1E With thermal isolator and mounting eye2) D
- 4001 to 6000 mm (157.52 to 236.22”)1) 2E Electronic transmitter
- 6001 to 8000 mm (236.26 to 314.96”)1) 3E 3300 pF range 1
- 8001 to 10000 mm (315 to 393.70”)1) 4E Further designs Order code
Cable, non-insulated, weighted Please add “-Z” to Order No. and specify Order
Add order code Y01 and plain text: “Insertion code(s).
length ... mm”
- 1000 to 2000 mm (39.37 to 78.74”)1) 0F Insertion length, specify in plain text: Y01
- 2001 to 4000 mm (78.78 to 157.48”)1) 1F Y01: ... mm
- 4001 to 6000 mm )157.52 to 236.22”)1) 2F Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
- 6001 to 8000 mm (236.26 to 314.96”)1) 3F Measuring-point number/identification (max. 16
characters); specify in plain text
- 8001 to 10000 mm (315 to 393.70”)1) 4F
Cable lengths up to 25000 mm (984.25”) are possi- Acceptance test certificate: Manufacturer's test C11
ble for non-conductive media. Cable lengths up to certificate M to DIN 55350, Part 18 and ISO 9000
15000 mm (590.55”) are possible for conductive Inspection Certificate Type 3.1 per EN 10204 C12
media. Contact nacc.smpi@siemens.com for Instruction manual Order No.
details.
English 7ML1998-5HE01
Process connection French 7ML1998-5HE11
Welded flange, 316L stainless steel, raised face German 7ML1998-5HE31
1” ASME 150 lb4) A1
Spanish 7ML1998-5HE21
1” ASME 300 lb4) A2 Note: The instruction manual should be ordered as
1” ASME 600 lb4) A3 a separate line item on the order.
1½” ASME 150 lb B1 This device is shipped with the Siemens Milltronics
1½” ASME 300 lb B2 manual CD containing the complete ATEX Quick
1½” ASME 600 lb B3 Start and instruction manual library.
2” ASME 150 lb C1 Accessories
2” ASME 300 lb C2 ½” NPT cable gland, nickel plated brass, fits cable C) 7ML1830-1JA
2” ASME 600 lb C3 diameter 6 to 12 mm (0.24 to 0.47”) -40 to +100 °C
3” ASME 150 lb D1 (-40 to +212 °F), IP68
3” ASME 300 lb3) D2 (General Purpose)
3” ASME 600 lb3) D3 ½” NPT cable gland, brass, ATEX II 2GD EEx d IIC C) 7ML1830-1JB
and EEx e II, fits cable diameter 6.5 to 14 mm (0.26
4” ASME 150 lb3) E1 to 0.55”), -60 to +130 °C (-76 to +266 °F), IP68
4” ASME 300 lb3) E2 (Explosion Proof)
4” ASME 600 lb3) E3 M20x1.5 cable gland, PA polyamide, ATEX II 2G C) 7ML1830-1JC
Welded flange, 316L stainless steel, Type A flat EEx e II, fits cable diameter 7 to 12 mm (0.28 to
faced 0.47”), -20 to +70 °C (-4 to +158 °F), IP68
DN 25, PN 164) J4 (General Purpose)
DN 25, PN 404) J6 M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC C) 7ML1830-1JD
DN 40, PN 16 K4 and EEx e II, fits cable diameter 10.5 to 15.9 mm
DN 40, PN 40 K6 (0.41 to 0.63”), under armour cable diameter 6.1 to
11.5 mm (0.24 to 0.45”), -60 to 130 °C (-76 to
DN 50, PN 16 L4 +266 °F), IP68 (Explosion Proof)
DN 50, PN 40 L6
Electronic transmitter kit (includes transmitter and 7ML1830-1KN
DN 80, PN 16 M4 driver)
DN 80, PN 403) M6 1) For process connections 1½” and larger
DN 100, PN 163) N4 2)
Available for PFA insulated cable versions 0E to 4E only
3)
Custom shipping methods required. Contact factory for more details.
4) Only for use with Versions 0A to 4A
■ Characteristic curves
■ Dimensional drawings
■ Schematics
■ Overview ■ Configuration
5
SITRANS LC500 is an inverse frequency shift capacitance level
or interface transmitter for extreme and critical process condi-
tions, such as oil and liquified natural gas (LNG) as well as toxic
and aggressive chemicals and vapours.
■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
SITRANS LC500 installation
• Simple push-button calibration and integrated local display
• Inverse frequency approach provides high resolution
• 2-wire loop powered 4 to 20/20 to 4 mA measurement signal
■ Technical specifications
Input
• Pre-detection alarm and full function diagnostics
Measuring range 1 to 3300 pF
• High temperature and pressure resistant (optional)
• Full-function diagnostics comply with NAMUR NE 43 Span Min. 3.3 pF
• Easy calibration locally or via HART (using SIMATIC PDM soft- Output
ware) Solid-state switch
- Output Galvanically isolated
■ Application - Protection Bipolar
SITRANS LC500’s advanced electronics provide one-step, - Max. switching voltage • 30 V (DC)
push-button calibration and local display for easy on-site instal-
• 30 V peak (AC)
lation and setup.
- Max. load current 82 mA
The unique mechanical probe design coupled with a high per-
formance transmitter gives superior performance in toxic and - Voltage drop < 1 V, typical at 50 mA
aggressive chemicals, acids, caustics, adhesives and in vis- - Time delay (pre or post switch- 1 to 60 s
cous conductive and non-conductive materials. ing)
The SMART 2-wire transmitter has HART® communications for Loop current 3.6 to 22 mA/22 to 3.6 mA (2-wire
remote commissioning and inspection. current loop)
• Key Applications: Oil/water or foam/liquid interface measure- Accuracy (transmitter)
ment in separators or coalescers, cryogenic applications in- Temperature stability 0.15 pF (0 pF) or < 0.25% (typi-
cluding C02 and liquified natural gas (LNG), distillation/regen- cally < 0.1%) of actual measured
eration tanks with high temperatures value, whichever is greater over
the full temperature range
Non-linearity and repeatability < 0.1% of range and actual mea-
sured value respectively
Accuracy Deviation < 0.1% of measured
value
- High temperature version with -60 to +400°C (-76 to +752 °F) Safety • Inputs/outputs fully galvanically
thermal isolator and enamel in- isolated
sulation • Polarity-insensitive current loop
- Cryogenic version -200 to +200 °C (-328 to +392 °F) • Fully potted
5
Contact • Integrated safety barrier
nacc.smpi@siemens.com for
details. • Diagnostics with fault alarm when: Primary variable (PV) out of limits,
system failure in measurement
Pressure range Pressure rating of process seal is circuit, deviation between A/D
temperature dependent. and D/A converter, check sum,
See Pressure/Temperature curves watch dog and self-checking
on page 5/231. facility
• Standard (PFA) -1 to 150 bar g (2175 psi g) • Function rotary switch Positions 0 to 9, A to F
• High temperature version -1 to 345 bar g (5004 psi g) • SMART communication Conforming to HART Communi-
(Enamel) cation Foundation (HCF)
Design Certificates and approvals
Material • General Purpose CE (complies with E.C.C. require-
• Wetted parts material ments of EN 55011 and
EN 61326)
- Standard rod 316L stainless steel
• Non incendive/Non sparking • CSA/FM Class 1, Div. 2,
• Probe insulation (rod) PFA, enamel Groups A, B, C, D T4
• Cable 316 Stainless steel/316 stainless • ATEX II 3G 2D EExn A [ib] IIC T6
steel PFA to T4 T100 °C
Probe diameter • Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
Groups E, F, G
• Rod version 16 mm (0.63") or 24 mm (0.95")
• ATEX II 1/2 GD EEx d [ia] T6 to
• Cable version 9 mm (0.35”) with PFA jacket, T1
6 mm (0.24”) without PFA jacket
• Intrinsically Safe2) • CSA/FM Class 1, Div. 1,
Active shield length Groups A, B, C, D T4
• Minimum (Rod version) 50 mm (1.97”), customer select- • ATEX II 1G EEx [ia] IIC T6 to T4
able (order number Y02) • Explosion Proof • FM Class 1, Div. 1, Groups A, B,
Probe length C, D T4
• Rod version Max. 3.5 m (138“) with 16 mm • ATEX II 1/2 GD EEx d [ia] IIC T6
rod, PFA to T1
Max. 1.5 m (59”) with 16 mm rod, • Marine Lloyd’s Register of Shipping, Cat-
enamel egories ENV1, ENV2, ENV3 and
ENV5
Max. 5.5 m (216“) with 24 mm
rod, PFA • Pressure PED 97/23/EC, CSA B51
• Cable version Max. 35 m (1378“) • Other C-TICK (Australia)
Process connection of probe 1) When operation is in areas classified as hazardous, observe restrictions
• Threaded mounting NPT [(Taper), ANSI/ASME according to relevant certificate. See also Pressure/Temperature curves on
B1.20.1] page 5/231.
2) Barrier required for Intrinsically Safe protection
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
• Flange mounting ASME, EN 1092-1
Enclosure
• Material Aluminium, epoxy-coated
• Cable inlet 2 x ½” NPT
• Degree of protection Type 4X/NEMA4X/IP68
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Threaded or Welded Flange 7ML 5 5 1 3 - SITRANS LC500, Threaded or Welded Flange 7ML 5 5 1 3 -
with Cable Sensor 77 7 77 - 77 77 with Cable Sensor 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version1) Approvals
Cable, 9 mm (0.35”) diameter, 316 stainless steel General Purpose 1
with PFA insulation, weighted CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2
Add order code Y01 and plain text: “Insertion ATEX II 3G 2D EExn A [ib] IIC T6 to T4 T100 °C;
length ... mm“ CSA/FM Class II and III, Div. 1, Groups E, F, G;
- 1000 to 2000 mm (39.37 to 78.74”) 0E CSA/FM Class I, Div. 1, Groups A, B, C, D T4; ATEX 3
- 2001 to 4000 mm (78.78 to 157.48”) 1E II 1G EEx ia IIC T6 to T44)
- 4001 to 6000 mm (157.52 to 236.22”) 2E
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
- 6001 to 8000 mm (236.26 to 314.96”) 3E FM Class I, Div.1, Groups A, B, C, D, T4 6
- 8001 to 10000 mm (315 to 393.70”) 4E
Longer lengths possible to a max. of 35000 mm Enclosure/Cable inlet
(114.83 ft). Contact nacc.smpi@siemens.com Aluminum epoxy coated
for details. 2 x ½" NPT, IP68 1
Cable, 6 mm (0.24”) diameter, 316L stainless steel, 2 x M20x1.5 (IP68, adapter) 2
non-insulated, weighted
Options
Add order code Y01 and plain text: “Insertion
No additional options A
length ... mm“
5
With mounting eye5) B
- 1000 to 2000 mm (39.37 to 78.74”)2) 0F
- 2001 to 4000 mm (78.78 to 157.48”)2) and 3) 1F Thermal isolator/remote version
- 4001 to 6000 mm (157.52 to 236.22”)2) and 3) 2F Without thermal isolator or remote electronics A
Isolator, only for use when temperature range is B
- 6001 to 8000 mm (236.26 to 314.96”)2) and 3) 3F
outside of -40 to +85 °C (-40 to +185 °F), explosion
- 8001 to 10000 mm (315 to 393.70”)2) and 3) 4F
proof approval -40 to +70 °C (-40 to +158 °F)
Cable lengths up to 25000 mm (984.25”) are possi-
Electronic output
ble for non-conductive media. Cable lengths up to
No transmitter supplied 0
15000 mm (590.55”) are possible for conductive 2-wire loop current 4 to 20 mA 1
media. Contact nacc.smpi@siemens.com for (transmitter MSP 2002-2 _3300 pF)
details.
Further designs Order code
Process connection (316L Stainless steel)
Threaded connection Please add “-Z” to Order No. and specify Order
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0 code(s).
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 Insertion length, specify in plain text: Y01
1¼” NPT [(Taper), ANSI/ASME B1.20.1] K0 Y01: ... mm
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B L0 Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
0202] Measuring-point number/identification (max. 16
Welded flange, raised face characters); specify in plain text
1½", ASME, 150 Ib B1
1½", ASME, 300 Ib B2 Acceptance test certificate: Manufacturer's test C11
1½", ASME, 600 Ib B3 certificate M to DIN 55350, Part 18 and ISO 9000
2", ASME, 150 Ib C1 Inspection Certificate Type 3.1 per EN 10204 C12
2", ASME, 300 Ib C2 Instruction manual See page 5/230
2", ASME, 600 Ib C3 Accessories See page 5/230
3", ASME, 150 Ib3) D1 1)
3", ASME, 300 Ib3) D2 A minimum span of 3 pF must be maintained
3", ASME, 600 Ib3) D3 2) Available with non-conductive media only
4", ASME, 150 Ib3) E1 3) Custom shipping methods required. Contact factory for more details.
4", ASME, 300 Ib3) E2 4) Barrier required for Intrinsically Safe protection
4", ASME, 600 Ib3) E3 5) Available in PFA insulated version only
6", ASME, 150 Ib3) F1
6", ASME, 300 Ib3) F2
6", ASME, 600 Ib3) F3
Welded flange, Type A flat faced
DN 40, PN 16 K4
DN 40, PN 40 K5
DN 50, PN 16 L4
DN 50, PN 40 L5
DN 80, PN 16 M4
DN 80, PN 403) M5
DN 100, PN 163) N4
DN 100, PN 403) N5
DN 125, PN 163) P4
DN 125, PN 403) P5
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Threaded or Welded Flange, 7ML 5 5 1 5 - SITRANS LC500, Threaded or Welded Flange, 7ML 5 5 1 5 -
with Rod Sensor 77 7 77 - 77 77 with Rod Sensor 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version Welded flange, raised face
Rod, 16 mm (0.63”), PFA insulated 1½", ASME, 150 Ib B1
Add order code Y01 and Y02 and plain text: “Inser- 1½", ASME, 300 Ib B2
tion length ... mm and active shield length ... mm” 1½", ASME, 600 Ib B3
- 200 to 1000 mm (7.87 to 39.37”)1) 0A 2", ASME, 150 Ib C1
- 1001 to 2000 mm (39.41 to 78.74”) 1A 2", ASME, 300 Ib C2
- 2001 to 3000 mm (78.78 to 118.11”)2) 2A 2", ASME, 600 Ib C3
- 3001 to 3500 mm (118.15 to 137.80”)2) 3A 3", ASME, 150 Ib2) D1
Rod, 16 mm (0.63”), PFA insulated with 35 mm 3", ASME, 300 Ib2) D2
(1.38”) stilling well in 316L stainless steel 3", ASME, 600 Ib2) D3
Add order code Y01 and Y02 and plain text: “Inser- 4", ASME, 150 Ib2) E1
tion length ... mm and active shield length ... mm” 4", ASME, 300 Ib2) E2
- 200 to 1000 mm (7.87 to 39.37”)1) and 3) 0B 4", ASME, 600 Ib2) E3
- 1001 to 2000 mm (39.41 to 78.74”)3) 1B 6", ASME, 150 Ib2) F1
- 2001 to 3000 mm (78.78 to 118.11”)2) and 3) 2B 6", ASME, 300 Ib2) F2
- 3001 to 3500 mm (118.15 to 137.80”)2) and 3) 3B 6", ASME, 600 Ib2) F3
5
Rod, 24 mm (0.94”), PFA insulated Welded flange, Type A flat faced
Add order code Y01 and Y02 and plain text: “Inser- DN 40, PN 16 K4
tion length ... mm and active shield length ... mm” DN 40, PN 40 K5
- 200 to 1000 mm (7.87 to 39.37”)4) 0C
- 1001 to 2000 mm (39.41 to 78.74”)4) 1C DN 50, PN 16 L4
- 2001 to 3000 mm (78.78 to 118.11”)2) and 4) 2C DN 50, PN 40 L5
- 3001 to 4000 mm (118.15 to 137.80”)2) and 4) 3C DN 80, PN 16 M4
- 4001 to 5000 mm (173.26 to 196.88”)2) and 4) 4C DN 80, PN 402) M5
- 5001 to 5500 mm (196.89 to 216.54”)2) and 4) 5C DN 100, PN 162) N4
Rod, 24 mm (0.94”), PFA insulated with 48 mm DN 100, PN 402) N5
(1.89”) stilling well in 316L stainless steel DN 125, PN 162) P4
Add order code Y01 and Y02 and plain text: “Inser- DN 125, PN 402) P5
tion length ... mm and active shield length ... mm” (Note: Flange bolting patterns and facings dimen-
- 200 to 1000 mm (7.87 to 39.37”)5) 0D sionally correspond to the applicable ASME B16.5,
- 1001 to 2000 mm (39.41 to 78.74”)4) 1D or EN 1092-1 standard.)
- 2001 to 3000 mm (78.78 to 118.11”)2) and 5) 2D
Approvals
- 3001 to 4000 mm (118.15 to 137.80”)2) and 5) 3D General Purpose 1
- 4001 to 5000 mm (173.26 to 196.88”)2) and 5) 4D CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2
- 5001 to 5500 mm (196.89 to 216.54”)2) and 5) 5D ATEX II 3G 2D EExn A [ib] IIC T6 to T4 T100 °C;
Rod, 16 mm (0.63”), Glassteel Enamel insulated CSA/FM Class II and III, Div. 1, Groups E, F, G;
Add order code Y01 and Y02 and plain text: “Inser- CSA/FM Class I, Div. 1, Groups A, B, C, D T4; ATEX 3
tion length ... mm and active shield length ... mm” II 1G EEx ia IIC T6 to T46)
- 250 to 1500 mm (9.84 to 59.06”)2) and 5) 0E ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
Rod, 16 mm (0.63”), Glassteel Enamel insulated, FM Class I, Div.1, Groups A, B, C, D, T4 6
with 40 mm (1.57”) stilling well in 316L stainless Enclosure/Cable inlet
steel Aluminum epoxy coated
Add order code Y01 and Y02 and plain text: “Inser- 2 x ½" NPT, IP68 1
tion length ... mm and active shield length ... mm” 2 x M20x1.5 (IP68, adapter) 2
- 250 to 1500 mm (9.84 to 59.06”)2) and 5) 0F Options
Process connection (316L Stainless steel) No additional options A
Threaded connection Slotted holes instead of standard vent holes in still- B
¾" NPT [(Taper), ANSI/ASME B1.20.1] A0 ing well (Refer to instruction manual for dimen-
1” NPT [(Taper), ANSI/ASME B1.20.1] B0 sions.)7)
1½” NPT [(Taper), ANSI/ASME B1.20.1] C0 Thermal isolator/remote version
2” NPT [(Taper), ANSI/ASME B1.20.1] D0 Without thermal isolator or remote electronics A
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E0 Thermal isolator, only for use when temperature B
R 1” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 range is outside of -40 to +85 °C (-40 to +185 °F),
R 1½” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] J0 explosion proof approval -40 to +70 °C (-40 to
R 2” [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] K0 +158 °F)
1¼” NPT [(Taper), ANSI/ASME B1.20.1] N0 Remote electronics with mounting bracket and
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] P0 cable8)
G 1” [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R0 • Length: 2 m (79") C
G 1½” [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B S0 • Length: 3 m (118") D
0202]
G 2” [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] T0 • Length: 4 m (158") E
• Length: 5 m (197") F
5
Inspection Certificate Type 3.1 per EN 10204 C12
Manufacturing Test Report (Electrode Test) C18
Instruction manual See page 5/230
Accessories See page 5/230
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½” or larger
4)
Available with process connection 1” or larger
5)
Available with process connection 2” or larger
6)
Barrier required for Intrinsically Safe protection
7)
Available with version 0B to 3B, 0D to 5D and 0F only
8) Available with approval option 1 only
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Single Piece Flanged with Rod 7ML 5 5 1 7 - SITRANS LC500, Single Piece Flanged with Rod 7ML 5 5 1 7 -
Sensor 77 7 77 - 7777 Sensor 777 77 - 7777
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version DN 100, PN 162) N4
Rod, 16 mm (0.63”), PFA insulated DN 100, PN 402) N5
Add order code Y01 and Y02 and plain text: “Inser-
tion length ... mm and active shield length ... mm” DN 125, PN 162) P4
- 250 to 1000 mm (9.84 to 39.37”)1) 0A DN 125, PN 402) P5
- 1001 to 2000 mm (39.41 to 78.74”) 1A Single piece flange with PTFE flange facing (appli-
- 2001 to 3000 mm (78.78 to 118.11”)2) 2A cable with versions 0A to 3A and 0C to 5C)7)
- 3001 to 3500 mm (118.15 to 137.80”)2) 3A 1½", ASME, 150 Ib B4
1½", ASME, 300 Ib B5
Rod, 16 mm (0.63”), PFA insulated with 35 mm 1½", ASME, 600 Ib B6
(1.34”) stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text: “Inser- 2", ASME, 150 Ib C4
tion length ... mm and active shield length ... mm” 2", ASME, 300 Ib C5
- 250 to 1000 mm (9.84 to 39.37”)3) 0B 2", ASME, 600 Ib C6
- 1001 to 2000 mm (39.41 to 78.74”)3) 1B 3", ASME, 150 Ib2) D4
- 2001 to 3000 mm (78.78 to 118.11”)2) and 3) 2B 3", ASME, 300 Ib2) D5
- 3001 to 3500 mm (118.15 to 137.80”)2)and 3) 3B 3", ASME, 600 Ib2) D6
5
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97”)]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Manufacturing Test Report (Electrode Test) C18
Instruction manual See page 5/230
Accessories See page 5/230
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½” or larger
4)
Available with process connection 1” or larger
5)
Available with process connection 2” or larger, and only available with pro-
cess connection options C1 to C3, D1 to D3, E1 to E3, F1 to F3, L4 and L5,
M4 and M5, N4 and N5, P4 and P5
6)
Available with version 0B to 3B, 0D to 5D and 0F only
7)
Not available with versions 0E and 0F
8)
Barrier required for Intrinsically Safe protection
9)
Available with approval option 1 only
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Extended Cable version with 7ML 5 5 2 3 - SITRANS LC500, Extended Cable version with 7ML 5 5 2 3 -
Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7 Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7
flange1) flange1)
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for short range continuous mea- face transmitter for short range continuous mea-
surement in large storage vessels. surement in large storage vessels.
Version2) Thermal isolator
Rod, 16 mm (0.63”), PFA insulated and 316L stain- Without thermal isolator A
less steel flexible extension tube Isolator, only for use when temperature range is B
Total insertion length: outside of -40 to +85 °C (-40 to +185 °F), explosion
Add order code Y01 and plain text: “Total insertion proof approval -40 to +70 °C (-40 to +158 °F)
length ... mm and Y02 and plain text: Active shield Electronic output
length ... mm”3) and 4) No transmitter supplied 0
- 5000 to 10 000 mm (196.85 to 393.70”)1) 0A 2-wire loop current 4 to 20 mA 1
- 10001 to 15000 mm (393.74 to 590.55”)1) 1A (transmitter MSP 2002-2 _3300 pF)
- 15001 to 20000 mm (590.59 to 787.40”)1) 2A
Further designs Order code
- 20001 to 25000 mm (787.44 to 984.25”)1) 3A Please add “-Z” to Order No. and specify Order
- 25001 to 30000 mm (984.29 to 1181.10”)1) 4A code(s).
- 30001 to 35000 mm (1181.14 to 1377.95”)1) 5A
Rod, 24 mm (0.94”), PFA insulated and 316L stain- Total Insertion length, specify in plain text: Y01
less steel flexible extension tube Y01: ... mm [min. PFA rod length 200 mm
Total insertion length: (7.87")]3)
Add order code Y01 and plain text: “Total insertion Active shield length, specify in plain text: Y02: ... Y02
■ Characteristic curves
■ Dimensional drawings
SITRANS LC500 probe version Standard Extended Cable version with Rod
Sensor
Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange
Threaded Available as standard – Available as standard
Flange Available as standard Available as standard Available as standard
Sanitary fitting clamp – – –
■ Schematics
German C) 7ML1998-1AB31
Note: The instruction manual should be ordered
as a separate line on the order.
5
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Required equipment
TS-2 Temperature Sensor
TS-2, 1 m cable C) 7ML1812-1AA1
TS-2, 5 m cable C) 7ML1812-2AA1
TS-2, 10 m cable C) 7ML1812-3AA1
■ Dimensional drawings
16 mm 209 mm
(0.6”) (8.2”) 106 mm
lid screws (4.2”)
172 mm (6 places) 91 mm
(6.8”) (3.6”)
programmer
285 mm
(11.2”)
267 mm
(10.5”)
1 2 3 4
5
5 6 7 8
9 A
0
D F
P U
C
lid
Suitable location for conduit entrances. mounting holes
Siemens Milltronics recommends using a punch (accessed under enclosure
for making holes in enclosure. lid) 4.3 mm (0.17”)
dia. / 4 places
customer
mounting screw
■ Schematics
SHLD
SHLD
SHLD
SHLD
COM
COM
WHT
BLK
Hot
Vel Aux
Input Input
Position SW1
Transducer Current O/P Bipolar I/O RS-232 I/O Temp Sensor P 24 V Output Input Power for 100/115/
max. load 200/230 V AC
average 20 mA operation
Pulse 200 mA (50/60 Hz,
1/10 duty 20 VA)
Notes:
1. Use RG62-A/U Coaxial (or equivalent) for extensions up to 183 m (600 ft). Run in grounded metal conduit, separate from other wiring.
2. Each relay has 1 set of form ‘C’ (SPDT) contacts, relay rated at 5A, 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.
Relay de-energized when in alarm conditions and energized for pump control.
5
9600 Kbps to 12 Mbps
industrial communications buses with true plug-and-play com-
patibility with products manufactured by Siemens. • Rack address 0 to 99
• Connection Slave
■ Benefits • SmartLinx module compatibility • SITRANS LU01
• Fast, easy installation • SITRANS LU02
• Direct connection: no additional installation required • SITRANS LU10
• Scaleable application layer allows for optimized network • SITRANS LUC500
bandwidth and memory requirements • MultiRanger 100/200
• Modules available for PROFIBUS DP, Allen-Bradley® Remote • HydroRanger 200
I/O and DeviceNetTM, Modbus® RTU
®Modbus is a registered trademark of Schneider Electric.
®Allen-Bradley is a registered trademark of Rockwell Automation Module type MODBUS RTU
TMDeviceNet is a trademark of Open DeviceNet Vendor Association
• Interface RS-232 or RS-485
5
PROFIBUS communications module
• English C) 7ML1998-1AQ03
• French C) 7ML1998-1AQ12
• German C) 7ML1998-1AQ32
• Saving and visualization of echo profiles for a wide range of C) Subject to export regulations AL: N, ECCN: EAR99
Siemens Milltronics level meters
• Copying of data for programming several devices
• Quick setup and commissioning of device
• Generation of configuration reports within seconds
Note:
The Dolphin Plus software is only available in English.
■ Application
Dolphin Plus is easy to install and use. Just load the software
from the CD. In minutes, you’re ready to set up or modify com-
plete parameter configurations for one or more devices.
Following configuration, you can alter parameters, upload and
download parameter sets to and from disk, and use parameter
sets saved from other instruments. Reading of echo profiles per-
mits fine tuning without the need for special instruments. Built-in
quick start wizards and help functions guide you through the en-
tire process.
Compatibility
Dolphin Plus works with a wide range of Siemens products, in-
cluding:
• SITRANS LUC500
• HydroRanger Plus
• SITRANS LU10
• SITRANS LU02
• SITRANS LU01
Connection to a Siemens instrument may be a direct RS-232 se-
rial connection or via an RS-485 converter or Siemens infrared
ComVerter, depending on the instrument being configured.
Meets VDE 2187 user interface requirements.
(Most other Siemens level devices use Simatic PDM configura-
tion software.)
5
External loop power supply 30 V DC max.
closed remote digital display for process instrumentation.
Display • 1.0“ (2.54 cm) high LCD
■ Benefits • Numeric range from -1000 to
+1999
• Easy setup
Certificates and approvals
• Approved for hazardous locations
Hazardous
• NEMA 4X, IP67 impact-resistant enclosure
• Intrinsically Safe • FM/CSA Class I, II, III, Div. 1,
• Simple two-step calibration Groups A, B, C, D, E, F, G T4
• Two modes of input allow for easy servicing, with no interrup-
• FM/CSA Class I, Zone 0,
tion of loop required Group IIC
■ Dimensional drawings
5
SITRANS RD100 dimensions
■ Schematics
5
(-292 to +700 °F)
digital display for process instrumentation.
• Type T, 0.1° Resolution: -180.0
■ Benefits
to +371 °C (-199.9 to +700 °F)
• RTD temperature • 100 Ω RTD: -200 to +750 ºC
• Easy setup and programming via front panel buttons or re- (-328 to +1382 ºF)
motely using RD software Output signal
• Display readable in sunlight
• Output • PDC output
• Universal input: accepts current, voltage, thermocouple and • 4 to 20 mA (optional)
RTD signals
• Modbus (optional)
• Single or dual 24 V DC transmitter power supply
• Relays 2 SPDT Form C relays, rated 3 A
• Serial communication using built in protocol or optional @ 30 V DC or 3 A @ 250 V AC,
Modbus® RTU non-inductive, auto-initializing
• Two optional relays for alarm indication or process control ap- (optional)
plications • Communications • RS-232 with PDC or
• Linear or square root function supported Modbus RTU
• RS-422/485 with PDC or
• Meter Copy feature to reduce setup time, cost or errors Modbus RTU
• RD software supporting remote configuration, monitoring and
Accuracy
logging for up to 100 displays
• 4 to 20 mA optional output ± 0.1% FS ± 0.004 mA
■ Application • Process input ± 0.05% of span ± 1 count,
square root: 10 to 100% FS
The RD200 is a universal remote display for level, flow, pressure,
• Thermocouple temperature input • Type J: ± 1 °C (± 2 °F)
temperature, weighing, and other process instruments.
• Type K: ± 1 °C (± 2 °F)
Data can be remotely collected, logged and presented from as • Type E: ± 1 °C (± 2 °F)
many as 100 displays on your local computer using the free
downloadable RD Software. • Type T: ± 1 °C (± 2 °F)
• Type T, 0.1° Resolution: ± 1 °C
The display can accept various inputs, including current, volt- (± 1.8 °F)
age, thermocouple, and RTD. This makes the RD200 an ideal fit
for use with most field instruments. • RTD temperature input • 100 Ω RTD: ± 1 °C (± 1 °F)
Rated operating conditions
The RD200 can be set up as a standard panel mount, or com-
bined with optional enclosures to allow it to house up to 6 dis- Ambient conditions
plays. Operating temperature range 0 to +65 ºC (+32 to +149 ºF)
• Key Applications: Tank farms, pump alternation control, local Design
or remote display of level, temperature, flow, pressure and
weighing instrument values, PC monitoring and data logging Weight 269 g (9.5 oz) (including options)
with RD Software. Material (enclosure) • 1/8 DIN, high impact plastic,
UL94V-0, color: gray
• Optional plastic, steel and stain-
less steel (Type 304, EN 1.4301)
NEMA 4 enclosures
Degree of protection Type 4X, NEMA 4X, IP65 (front
cover); panel gasket provided
Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS RD200 C) 7 M L 5 7 4 0 - SITRANS RD200 C) 7 M L 5 7 4 0 -
A universal input, panel mount remote digital dis- 77 7 77 - 0 A A universal input, panel mount remote digital dis- 777 77 - 0 A
play for process instrumentation. play for process instrumentation.
Input voltage Accessories
85 to 265 V AC, 50/60 Hz; 90 to 265 V DC, 1 SITRANS RD200 copy cable 2.1 m (7 ft) C) 7ML1930-1BR
20 W max. SITRANS RD200 RS-232 serial adapter (copy C) 7ML1930-1BS
12 to 36 V DC; 12 to 24 V AC, 6 W max. 2 cable included)
Transmitter supply SITRANS RD200 RS-422/485 serial adapter (copy C) 7ML1930-1BT
cable included)
None A
RS-232 to RS-422/485 isolated converter C) 7ML1930-1BU
Single 24 V DC transmitter supply1) B
RS-232 to RS-422/485 non-isolated converter C) 7ML1930-1BV
Dual 24 V DC transmitter supply1) and 2) C
SITRANS RD200 RS-232 and RS-485 isolated C) 7ML1930-1BW
Output multi-input adapter board
None A USB to RS-422/485 isolated converter C) 7ML1930-1BX
2 relays B USB to RS-422/485 non-isolated converter C) 7ML1930-1BY
4 to 20 mA output C USB to RS-232 converter C) 7ML1930-1DC
Communication RD Software CD for 1 to 100 displays C) 7ML1930-1CC
Modbus disabled 0 Modbus option enabled 7ML1930-1CD
Modbus enabled 1 Low cost polycarbonate plastic enclosure for 1 dis- C) 7ML1930-1CF
play
Approvals
5
Thermoplastic enclosure
CE, UL, CUL 1 For use with 1 display C) 7ML1930-1CG
Instruction manual For use with 2 displays C) 7ML1930-1CH
English C) 7ML1998-5JS01 For use with 3 displays C) 7ML1930-1CJ
German C) 7ML1998-5JS31 For use with 4 displays C) 7ML1930-1CK
Note: The instruction manual should be ordered as For use with 5 displays C) 7ML1930-1CL
a separate line item. For use with 6 displays C) 7ML1930-1CM
This device is shipped with the Siemens Milltronics Stainless steel enclosure (Type 304, EN 1.4301)
manual CD containing ATEX Quick Starts and For use with 1 display C) 7ML1930-1CN
instruction manuals.. For use with 2 displays C) 7ML1930-1CP
Other Instruction manuals For use with 3 displays C) 7ML1930-1CQ
SITRANS RD Enclosures, English C) 7ML1998-5JX01 For use with 4 displays C) 7ML1930-1CR
SITRANS RD Serial Adapters, English C) 7ML1998-5JV01 For use with 5 displays C) 7ML1930-1CS
SITRANS RD Software, English C) 7ML1998-5JW01 For use with 6 displays C) 7ML1930-1CT
SITRANS RD Enclosures, German C) 7ML1998-5JX31 Steel enclosure
SITRANS RD Serial Adapters, German C) 7ML1998-5JV31 For use with 1 display C) 7ML1930-1CU
SITRANS RD Software, German C) 7ML1998-5JW31 For use with 2 displays C) 7ML1930-1CV
For use with 3 displays C) 7ML1930-1CW
For use with 4 displays C) 7ML1930-1CX
For use with 5 displays C) 7ML1930-1CY
For use with 6 displays C) 7ML1930-1DA
1)
Available with input voltage option 1 only
2)
Available with output option C only
■ Dimensional drawings
■ Schematics