You are on page 1of 6

PACKAGED POSITIVE Datasheet No.

DISPLACEMENT ROTARY SCREW Item No.:


Unit:
PT Caltex Pacific Indonesia PLANT AND INSTRUMENT AIR
P.O. No.:
COMPRESSOR
Inquiry No.:
SPECIFICATION SHEETS
(Continued) Engineer: REV BY DATE
Process:
Mech:
Sheet No.: 1 Of 9

1 Applicable To : ⌧ Proposal Purchase As Built Furnished by


2 Client PT Caltex Pacific Indonesia Plant Plant Air Facility
3 Site Duri - Area 10 Driver Equip. Electric Motor
4 Service Plant Air Compressor No. Required 4 (4X50% configuration)
5 Manufacturer Model Serial No.
6 Drive System: Direct Coupled Geared Coupled V-Belt
7 Note: Information to be completed: By Purchaser By Manufacturer

8 GENERAL
9 OPERATING CONDITIONS BEARING HOUSING CONSTRUCTION:
10 1. 2. Type: Separate Integral
11 RADIAL BEARINGS:
12 Gas Handled wet air Type: Ball Roller Sieve
13 Capacity, SCF/H @ 60 0F, 14.7 PSIA Dry 394.1 THRUST BEARING:
14 Weight Flow, lb/min (Wet) (Dry) 29.57 (wet) 28.67(dry) Type:
15 Molecular Weight 28.43 LUBRICATION:
16 Cp/Cv (Kavg) 1.4 Type: Ring-Oiled Flood Other
17 Relative Humidity (%) 100 COOLING WATER:
18 Inlet Pressure, psia 14.6 Required: Yes No
0
19 Inlet Temperature, F 90 Flow: GPM
20 Capacity Inlet, ft3/min(Wet) 297
21 Discharge Pressure, psia 297 CONNECTIONS:
0
22 Discharge Temperature F 120 (max) Size Rating Facing Position
23 KW Required (All Losses Incl.) Inlet ANSI 150#
24 Speed, RPM Outlet ANSI 150#
25 Drains
26
27
28 Max. Cont. Speed RPM Efficiency %
29 Criticals: 1st RPM 2nd RPM COMPRESSOR MATERIALS:
30 Casing
31 CONTROL: Rotors
32 Type: Shaft
33 Source: Manual FC ⌧ PC TC Shaft Sleeves
34 Timing Gears
35 CONSTRUCTION FEATURES Other
36 CASING:
37 Max. Work Press. PSIG Max. Des. Press. PSIG DRIVE SYSTEM:
38 Test Pressure Hydro. Helium Coupling Furnished By:
0 0
39 Max. Oper. Temp. F Min. Oper. Temp. F Make: Model:
40 Gear Furnished By:
41 ROTORS: Make: Model: SF:
42 Type Fabrication: V-Belt Drive Furnished By:
43 Pulley Sizes: Belt Size:
44 Guards Furnished By:
45 Type:
46 SHAFT:
47 Dia. @ Rotor INCH Dia. @ Coupling INCH APPLICABLE SPECIFICATIONS:
48 Span INCH # SP-CGS10-ME-Z-002 Packaged Air Compresor Specification
49 Shaft End: Tapered Cylindrical
50 Rotation (Viewed From Driven End) CW CCW
51
52 SHAFT SEALS:
53 Make :
54 Model :
55 Description :
56

i:\caltex\255\datsheet\z002
PACKAGED POSITIVE Contract:

DISPLACEMENT ROTARY SCREW Item No.:

PT Caltex Pacific Indonesia PLANT AND INSTRUMENT AIR Unit:

COMPRESSOR P.O. No.:


SPECIFICATION SHEETS Inquiry No.:
(Continued) Engineer: REV BY DATE
Process:
Mech:
Sheet No.: 2 Of 9

1 GENERAL (Continued)
2 SHOP INSPECTION AND TESTS: BASEPLATE:
3 REQ'D WITNESS Open Construction
4 Shop Inspection ⌧ Drip Rim With Open Drain
5 Mechanical Run ⌧ Horizontal Adjusting Screws for Equipment
6 Performance Test ⌧ Vertical Adjusting Screws for Equipment
7 Vibration Test ⌧ Suitable for Point Support
8 Disassemble-Reassemble After Test Suitable for Perimeter Support
9 Check Brgs & Seals After Test ⌧ Grouting Prep Epoxy
10 Noise Level Test ⌧
11 Preparation For Shipment ⌧
12
13 MISCELLANEOUS:
14 WEIGHTS: ⌧ Inlet Filter-Silencer, 10 micron, Dry Type
15 Compressor lb ⌧ Air/Oil Separator
16 Driver lb ⌧ Instrument Quality Air After-Filter
17 Gear lb Receivers - Plant Air - Instrument Air
18 V-Belt Drive lb ⌧ Aftercoolers - Water/Air Cooled
19 Base lb ⌧ Moisture Separators
20 Max. For Maintenance (Identify) lb ⌧ Air Dryer with Pre- and After-Filters
21 ⌧ Relief Valves
22 Total Shipping Weight lb ⌧ Interconnecting Piping
23 ⌧ Oil Cooler
24 SPACE REQUIREMENTS: Thermostatic Control Valve for Oil Circuit
25 Complete Unit: L ft ft ft Oil Filter, 10 micron, Full Flow
26 Automatic Blowdown Valve with Muffler
27 ALLOWABLE PIPING FORCES AND MOMENTS: Minimum Discharge Pressure Valve
28 Modulating Capacity Control System
29 INLET DISCHARGE Dual Control - Automatic
30 Forces Momt. Forces Momt. Forces Momt. ⌧ Control Panel
31 lb ft-lb lb ft-lb lb ft-lb
32
33 Axial
34 Vertical
35 Horiz. 90°
36
37

38 REMARKS:
39 1
40
41
42
43
44
45
46
47
48
49
50
51
PACKAGED POSITIVE Contract:
DISPLACEMENT ROTARY SCREW Item No.:

PT Caltex Pacific PLANT AND INSTRUMENT AIR Unit:


COMPRESSOR P.O. No.:
SPECIFICATION SHEETS Inquiry No.:
(Continued) Engineer: REV BY DATE
Process:
Mech:
Sheet No.: 3 OF 9

1 LOCATION, SITE DATA


2 LOCATION: NOISE SPECIFICATIONS:
3 Indoor Heated Under Roof Applicable to Machine:
4 ⌧ Outdoor Unheated Partial Sides See Specification
5 Grade Mezzanine Applicable to Neighborhood
6 Winterization Req'd ⌧ Tropicalization Req'd See Specification
7 SITE DATA Acoustic Housing: Yes No
8 Elevation ft Barometric psia
0 0
9 Temperature F Summer F
10 Relative Humidity %
11 UNUSUAL CONDITIONS: PAINTING:
12 Dust Fumes Manufacturer's Std.
13 Other Others
14
15
16

17 SHIPMENT:
18 Domestic Export Export Boxing Required
19 Outdoor Storage for 3 Months
20

21 AREA CLASSIFICATION:
22 Class Group Division
23
24 UTILITIES
25 UTILITY CONDITIONS: UTILITY CONSUMPTION:
26 STEAM DRIVER HEATING LOCKED Locked Full Load
0 0
27 Inlet,min psig F psig F ELECTRIC hp Rotor Amps Amps
0 0
28 Norm. psig F psig F Main Driver
0 0
29 Max. psig F psig F Aftercooler Fan Motor
0 0
30 Exh, min psig F psig F Main Lube Oil Pump
0 0
31 Norm. psig F psig F Cooling Water Pump
0 0
32 Max. psig F psig F Oil Heater W Volts Hz
33 ELECTRICITY Space Heater W Volts Hz
34 Drivers Heating Control Shutdown W Volts Hz
35 Voltage
36 Hertz STEAM lb/h psig psig psig
37 Phase Main Driver To
38 COOLING WATER To
0 0
39 Temp.: Inlet F Max. Return F
40 Press.: Norm psig Design psig COOLING WATER
41 Min. Return psigMax Allow. ΔΡ psig L.O. After Other
42 Water Source Cooler Cooler
43 AIR/GAS (FOR MOTOR(S)): Quantity, GPM
0
44 Max. Press psig Min. Press psig Inlet Temp., F
0
45 Gas Composition Outlet Temp., F
46 Corrosive Present Inlet Press., psig
47 Outlet Press., psig
48 Max Press., psig
49 Total C.W., GPM
50

51 REMARKS:
52
53
PACKAGED POSITIVE Contract:

DISPLACEMENT ROTARY SCREW Item No.:

PT Caltex Pacific Indonesia PLANT AND INSTRUMENT AIR Unit:


P.O. No.:
COMPRESSOR
SPECIFICATION SHEETS Inquiry No.:
(Continued) Engineer: REV BY DATE
Process:
Mech:
Sheet No.: 4 OF 9

1 LUBE OIL SYSTEM


2 PIPING MATERIALS: COOLERS: ⌧ Air Water
3 Carbon Stainless Single Twin
4 Steel Steel With Bypass & Temp. Control Valve
5 Complete System Manual Auto
0
6 Downstream of Filters Heating Steam to Waterside @ psig F
7 Return Piping Fouling Factor: Shell Side Tube Side
8 Make Type
0
9 Carbon Steel Slip-On Flanges on Stainless Steel Piping Duty Btu/h Surface F
10 Code(s)
11 SYSTEM COMPONENT SUPPLIERS: Design Pressure, psig Shell Side Tube Side
12 Manufacturer Model Tubes: O.D. in
13 Electric Motor(s) Wall Thickness (Avg.)(Min.) in
14 Oil Cooler(s) Length in Number:
15 Oil Filter(s) Materials: Tubes
16 Check Valve(s) Tube Sheets
17 Cooling Water Pump Shell
18 L.O. Pump Tube Support
19 Shell Cover/Flange
20
21
22 SYSTEM PRESSURES:
23 Design psig Hydrotest psig
24 Pump Relief Valve(s) Settings psig
25 FILTERS:
26 LUBE OIL PUMP: Single Twin
27 Motor Driven Other ASME Code Design ASME Code Stamp
28 Safety Guard Required Micron (µ)
29 Filter Medium
30 RESERVOIR: (AIR/OIL SEPARATOR) Design Pressure, psig
31 Material ΔΡ Clean (psig)
32 Capacity gal Mfr. ΔΡ Collapse (psig)
33 Baffle Required Interior Coating Casing Material
34 Free Surface Area ft2 Filler Manufacturer
0
35 Heater(s) Electric Steam Min. Site F Furnish Set of Spare Cartridge with Filters
36 Filter/Breather Flanged Vent
37 Press. Relief Vent Insulation Supports
38 Spring Loaded Fill Cap w/S.S. Strainer
39

40 REMARKS:
41
42
43
44
45
46
47
48
49
50
Contract:
PACKAGED POSITIVE
DISPLACEMENT ROTARY SCREW Item No.:
Unit:
PT Caltex Pacific Indonesia PLANT AND INSTRUMENT AIR
P.O. No.:
COMPRESSOR
Inquiry No.:
SPECIFICATION SHEETS
(Continued) Engineer: REV BY Date:
Process:
Mech:
Sheet No.: 5 OF 9

1 LOCAL CONTROL PANEL:


2 Furnished By Vendor
3 ⌧ Base Mounted ⌧ Free Standing ⌧ Weatherproof ⌧ Totally Enclosed Extra Cutouts
4 ⌧ Vibration Isolators Strip Heaters ⌧ Purge Connections
5 ⌧ Annunciator With First Out Indication Located on Local Panel
6 ⌧ Customer Connections Brought Out to Terminal Boxes by Vendor
7 REMARKS: Compressor to enable communication with control room PLC on status, duty/stanby, emergency start/remote stop
8 and load signals.
9

10 INSTRUMENT SUPPLIERS:
11 Pressure Gages: Mfr. Size & Type
12 Temperature Gages: Mfr. Size & Type
13 Level Gages: Mfr. Size & Type
14 Diff. Pressure Gages: Mfr. Size & Type
15 Pressure Switches: Mfr. Size & Type
16 Differential Pressure Switches: Mfr. Size & Type
17 Temperature Switches: Mfr. Size & Type
18 Level Switches: Mfr. Size & Type
19 Control Valves: Mfr. Size & Type
20 Pressure Relief Valves: Mfr. Size & Type
21 Thermal Relief Valves: Mfr. Size & Type
22 Sight Slow Indicators: Mfr. Size & Type
23 Gas Flow Indicator: Mfr. Size & Type
24 Vibration Equipment: Mfr. Size & Type
25 Tachometer: Mfr. Size & Type
26 Solenoid Valves: Mfr. Size & Type
27 Annunciator: Mfr. Model and No. of Points
28
29 Note: ⌧ Supplied by Vendor Supplied by Contractor
30 PRESSURE GAGE REQUIREMENTS: TEMPERATURE GAGE REQUIREMENTS:
31 Locally Local Locally Local
32 FUNCTION Mounted Panel FUNCTION Mounted Panel
33 Lube Oil Pump Discharge ⌧ ⌧ Oil Cooler Outlet ⌧ ⌧
34 Lube Oil Filter ΔΡ ⌧ ⌧ Compressor Discharge ⌧ ⌧
35 Air /Oil Separator ΔΡ ⌧ ⌧ Aftercooler Discharge ⌧ ⌧
36 Compressor Discharge ⌧ ⌧
37
38

39 SWITCH CLOSURES:
40 Alarm Contacts Shall: Open Close to Sound Alarm and be Norm Energized Deenergized
41 Shutdown Contact Shal Open Close to Trip and Be Normally Energized Deenergized
42
43 NOTE: Normal Condition is Where Compressor is in Operation.
44

45 ALARM & SHUTDOWN SWITCHES:


46
47 FUNCTION Pre-alarm Trip FUNCTION Pre-alarm Trip
48 ⌧ Low Lube Oil Pressure ⌧ Compressor High Discharge Temp.
49 ⌧ High Lube Oil Filter ΔΡ Hi Inlet Air Filter ΔΡ
50 ⌧ Low Lube Oil Reservoir Level ⌧ Compressor Motor Shutdown
51 High Liquid Level - Separator
52 High Liquid Level - Cond. Traps
53
54

You might also like