You are on page 1of 1

PROJECT NAME: JOB No

DESIGNED: vinay CHECKED: VINAY DATE

FOOTING NAME: F1
2
COLUMN SIZE : 200 X 600 Fy = 500 ( N / mm )
2
Fck = 25 ( N / mm )
LOAD DATA : DL+LL+WL EQ
2
S.B.C = 200 ( kN / m )
P (kN ) 400 0
FX ( kN ) 0.00 0
FZ ( kN ) 0.00 0 4.572
MX ( kN m ) 0 0
MZ ( kN m ) 0 0

Area required : = 440 1.424


200 B 10
2
= 2.2 M L 15
1.986
PROVIDE = 3.048 4.572 3.048

2
Area Provided : = 13.935456 M ok

Depth of Footing :
Reqd. d = 0.376 m
PROVIDED D = 0.375 m 15
deff = 0.325 m

Additional Moments:
Mx1 = 0 ( kN m )
Mz1 = 0 ( kN m )

Final Loads : P = 400 ( kN )


MX = 0 ( kN m )
MZ = 0 ( kN m )

2
Pmax = 28.70 ( kN / m ) ok For Design P = 0 ( kN / m2 ) ok
2
Pmin = 28.70 ( kN / m ) ok
ok
CHECK: FOR EQ,LOADS
2
Pmax = 0.00 ( kN / m ) revise For Check P = 0 ( kN / m2 )
Pmax 2
Pmin = 0.00 ( kN / m ) revise

2
Pmax = 68.90 ( kN / m ) revise
Mxmax 2
Pmin = 58.77 ( kN / m ) ok

2
Pmax = 82.58 ( kN / m ) revise
Mymax 2
Pmin = 61.18 ( kN / m ) ok

CHECK FOR TWO WAY SHEAR:

tv = 28.70 3.048 4.572 0.525 0.925 1.5


2900 325
tv
2
= 0.61 ( N / mm )

tc
2
= 1.04 ( N / mm )
> 0.61 ok

DESIGN FOR FLEXURE:


M = 28.70 1.986
2
M = 56.607 ( kN m )
K = 0.804
Pt = 0.192
2
Ast = 624.652 (mm )

Provide 10 126 C/C


SAY 150
No of bars SHORTER 31
LONGER 21

CHECK FOR ONEWAY SHEAR :

tv = 28.70 1.986 0.325 1.5


325
tv
2
= 0.220 ( N / mm )

tc
2
= 0.300 ( N / mm )
> 0.220 ok

You might also like