You are on page 1of 1

NOZZLE LOAD TRANSMITTAL

Jacobs Engineering India PVT LTD. JE Proj. No : 44AB6000 Location : KALATALAV, BHAVNAGAR, GUJARAT
Jacobs House, Ramkrishna Mandir Road, Client : NIRMA Project : NIRMA PAP
Kondivita, Andheri (East) Plant : Drawing No: GV/28348/18
Mumbai, 400059, Unit : 7200 Rev No : A
Tel : +91-22-2681 2000 Plan Dwg : -
Doc. No :
REFERENCE DATA PIPE ASSESSMENT CONDITION FROM : Piping Stress Group
CALC. No: CN-L1-01015 TEMPERATURE: 55.0 o
C TO : Vendor
LINE No: 723511-LSB-200-FRC PRESSURE : 5.0 barg DATE : 19-Dec-18

EQUIPMENT NO: HX-72102 NOZZLE NO: N4 NOZZLE SIZE: 8" NODE NO : 3230

2190

Notes :
1) All loads are at nozzle shell junction.

ANALYSIS APPROACH : NOZZLE FLEXIBILITY EXCLUDED


SPRING RATES USED
Stiffness Deflections
Along X Axis - N per mm Along X Axis mm
Along Y Axis - N per mm Along Y Axis mm
Along Z Axis - N per mm Along Z Axis mm
About X Axis - N-m per degree Rotating About X Degrees
About Y Axis - N-m per degree Rotating About Y Degrees
About Z Axis - N-m per degree Rotating About Z Degrees
EXTERNAL PIPING ACTIONS AT NOZZLE NECK.
LOAD FORCES (N) MOMENTS (N-m)
TYPES OF LOADING
CASE Fa Fb Fc Ma Mb Mc
Operating +-624 +-4 +-405 +-51 +-145 +-29
Sustained +-563 +-44 +-394 +-11 +-198 +-6

Allowable loads 370 370 370 150 150 150


NOTES :
OPE = Operating temp. + Design Press + Weight
SUS = Weight + Design Press A ISSUED FOR APPROVAL VW VN
REV. DESCRIPTION BY Chk'd By
APPROVAL :
Yes
Signature
NO (Comments)-

Note: Please return to the Jacobs Piping Engineer after confirmation