DETC2015-47613
ABSTRACT INTRODUCTION
Desalination of high salinity water is an effective way of The Indian government has expressed the goal of providing
improving the aesthetic quality of drinking water and has been clean drinking water to all of its citizens, but this goal is yet to
demonstrated to be a characteristic valued by consumers. be achieved [1]. In particular, the challenges of water scarcity
Across India, 60% of the groundwater, the primary water and brackish water represent a significant threat to India’s
source for millions, is brackish or contains a high salt content future health and water security.
with total dissolved solids (TDS) ranging from 500 parts per
million (ppm) to 3,000ppm. The government does not provide Current State of In-Home Water Treatment
sufficient desalination treatment before the water reaches the The 2011 Census of India found that piped water is
tap of a consumer. Therefore consumers have turned to in-home supplied to 71.2% of urban households and 35% of rural
desalination. However, current products are either expensive or households [2]. However, no major Indian city is able to
have low recovery, product water output per untreated feed provide a 24-hour water supply, with most supplying only 4-5
water, (~30%) wasting water resources. Electrodialysis (ED) is hours of water each day [3]. Additionally, quality of the
a promising technology that desalinates water while supplied water is an issue. Though 12% of the water supply in
maintaining higher recovery (up to 95%) compared to existing urban areas of India is treated before delivery [4],
consumer reverse osmosis (RO) products. This paper first approximately 70% of piped water that was tested was
explores the in-home desalination market to determine critical designated as not potable, due to bacterial and chemical
design requirements for an in-home ED system. A model was contamination [3]. Because current government infrastructure is
then used to evaluate and optimize the performance of an ED not able to reliably deliver safe, desalinated, and
stack at this scale and designated salinity range. Additionally, uncontaminated water to homes, consumers have turned to in-
testing was conducted in order to validate the model and home water purification. Approximately 53% of households in
demonstrate feasibility. Finally, cost estimates of the proposed India use at least one form of water purification, which may
in-home ED system and product design concept are presented. take the form of straining water though a cloth, boiling, or use
The results of this work identified a system design that provides of in-home reverse osmosis units [3]. Based on preliminary
consumers with up to 80% recovery of feed water with cost and consumer interviews, people using treatment systems to reduce
size competitive to currently available in-home RO products. TDS levels are interested in a product that minimizes the
percentage of water wasted.
MODELING
ED stack setup
The experimental test configuration consisted of one (1)
PCCell ED 64002 lab-scale test unit [16] outfitted with ten (10)
anion exchange membrane and cation exchange membrane
pairs [19] and the associated spacers, each with an effective
area measuring 8 cm x 8 cm, and titanium electrodes with
platinum-iridium alloy coating.
This stack is the only commercially available stack which
allowed for testing of water treatment capacity in a size similar
to that of an in-home water treatment system. Additionally, this Figure 4. Flow Diagram of Experimental Setup
stack is representative since it contains parts such as the
membranes that would be identical to one used for an in-home
system. Through modeling it was found that the form factor of Testing of ED stack – Phase I
this stack could be incorporated into a similar package as The ED stack was initially tested to verify whether the
current RO products on the market. model was applicable for the test conditions selected and also
The test solution was split into two (2) 1L beakers, one for to evaluate ways to improve the design of the ED stack and the
each of the diluate and concentrate streams. Two (2) Iwaki experimental setup. Tests were conducted with 10 cell pairs at
centrifugal pumps, model MD-20RZ(T) [20], were used to feed an influent salinity of 3,000 ppm. A total of 3.75L (2.62L
the diluate and concentrate streams into the ED stack, and diluate and 1.13L concentrate) was tested in batch mode. The
tubing off of the stack discharge was returned to the beakers, recovery ratio was set at 70% to maximize recovery given the
recirculating the two test streams. King 7430 series rotometers initial equipment size, and the recirculation rate was operated
with valves [21] were used to vary the flow rate through the between 20-25 L/h. To verify the effect of voltage on time to
stack, and manual-read pressure gauges were installed to desalinate, two tests were run at different voltage levels: the
monitor pressure upstream and downstream of the stack in the first test was performed at a total voltage of 16V, or
diluate and concentrate streams. approximately 1.6V/cell pair; the second test was performed
Deionized water was mixed with lab-grade sodium with a total of 10V, or approximately 1.0V/cell pair. 1V/cell
chloride [22] to formulate the 3,000-ppm test solution. During pair and 1.6V/cell pair were chosen as they were representative
the test, magnetic stirring plates were used to mix the diluate of the operating limits set by the manufacturer. A third test was
and concentrate beakers, and a Jenco Model 3250 then run on the 10 cell pair stack with a total of 16V, or
conductivity/salinity/temperature meter [23] was used to approximately 1.6V/cell pair, and an increased recirculation
monitor conductivity and salinity levels within each beaker rate of 40 L/h. Results from Phase I, experiment 3, are
throughout the experiment. A separate solution of deionized provided below in Figure 5 with error bars reflecting a
water and sodium sulfate (0.2M) [24] was formulated for the maximum uncertainty of 13%.
electrode rinse stream, which was recirculated during each test
by a third Iwaki centrifugal pump at a rate of approximately 2.5
LPM.
2500
N
2000 where Vt is the total applied voltage in V, Vel is the voltage drop
1500
across the electrodes in V, while N is the number of cell pairs in
the stack. The cell pair voltage can further be expressed as a
1000 function of the current density, i, in the stack and the resistance
and voltage across the membranes, which are themselves a
500
function of the salt concentration in the diluate and concentrate
0 streams as:
0 10 20 30 Vcp i R(Cdil , Ccon ) Emem (Cdil , Ccon ) (2)
Time (min)
This is depicted using a circuit diagram in Figure 6.
Figure 5. Phase I, Test 3 results (10 cell pairs, 1.6V/cell pair, 40 L/h)
Time for 1 L to reach 350 ppm (min)
Input: 10
Sf = 3000 ppm Input:
8 Vcp = 1.6 V
N = 25 cell pairs
Time for 1 L to reach
5 Lab stack total Sf = 3000 ppm
350 ppm (min)
voltage constraint
6 from manufacturer
4
4 Desired operating
range: >12 L/h
2
3 For commercial systems, increase
Max. Vcp for long N at Vcp=1.6 V
membrane life 0
(20% less than ult. max.) 0
30 10
40 5020
2 N
1.0 1.2 1.4 1.6 1.8 2.0 Figure 8. Model results showing variation of time to desalinate 1
Vcp (V) L of diluate to 350 ppm from 3000 ppm with total voltage for a cell
Figure 7. Model results showing variation of time to desalinate 1 pair voltage of 1.6 V. Desired operating range and test stack constrains
L of diluate to 350 ppm from 3000 ppm with voltage across a cell pair are shown by horizontal and vertical dashed lines respectively.
with 25 cell pairs in the stack.
Testing of ED Stack - Phase II
Next, keeping Vcp = 1.6 V, the area of the membranes in the A final round of testing was conducted to test performance
ED stack was increased by increasing the number of under the optimized conditions of 18 cell pairs and 1.6 V
membranes and hence the number of cell pairs. The applied per cell pair. In addition to these changes, the tubing
recirculation rate proportionately increased with the increase in and transfer pumps were replaced to make the test
number of cell pairs to maintain a constant flow velocity in the configuration more representative of future product conditions.
channel. The velocity was an optimal value to maintain a low The tubing was downsized from ½-in. ID to ¼-in. ID. The
pressure drop in the stack and to keep the pressure loading on diluate and condensate centrifugal transfer pumps were
the membrane low. Figure 8 shows how desalination time replaced by KNF Flodos NF300 KPDC diaphragm pumps [25]
reduces with increasing number of cell pairs. The resulting total with a smaller pump chamber compared to the Iwaki
voltage is also shown in the figure. The manufacturer centrifugal pumps originally used for testing [20], the ability to
recommended voltage limit was 33 V with a 3 V drop across operate even with air in the tubes, and a lower capital cost.
the electrodes [18]. This limited the peak lab stack performance A total of 2.96 L (2.41L diluate and 0.55L concentrate)
to just under 5 min of desalination time with 18 cell pairs. This with a salinity of 3000 ppm was created, and recovery was set
design point predicted by the model, graphically depicted at the to 80%. To maintain the flow velocity in the channels, the
intersection of the dashed lines in the figure, was selected for recirculation flow rate was increased linearly with the increase
final validation by experimentation. For a commercial in-home from 10 membrane cell pairs to 18 membrane cell pairs to a
ED stack, increasing the number of cell pairs beyond 18 can total of approximately 72 L/h. Two tests were performed in
further reduce desalination time. The final capital costs and succession, with a period of stack flushing with fresh 3000 ppm
required operating margins would determine the maximum salinity solution lasting approximately 5 minutes between each
number of cell pairs that could be put in a commercial stack. test. The peak power consumed in the tests was 88 W: 53 W for
Peak ED stack power consumption at Vcp = 1.6 V was low, three pumps and 35 W for the ED stack. As shown in Figure 9,
around 40 W for N = 18 and 90 W for N = 40, equating to the tests achieved the target salinity concentration within 13
electricity consumption (when including 53 W for pumping minutes, which was within 13% of the performance predicted
power) of less than $6 per year, therefore not constraining our by the model. The error bars shown reflect a maximum
design. uncertainty of 8%. Thus, we have proved that electrodialysis
could be used to desalinate feed water of 3000 ppm salinity to
350 ppm at 80% recovery and greater than 12 L/h clean water
production rate.
[7] KENT RO Systems Ltd, Kent Supreme RO. Noida [20] Iwaki America, Iwaki MD-20RZ(T) pump. Holliston,
201309, Uttar Pradesh, India. Massachusetts 01746, USA, 2014.
[21] King Instrument Co., King 7430 glass tube flow meter
[8] Hindustan Uniliver Limited - Pureit, Pureit Marvella
with 65 MM scale flow range, tube 2-34-G-041. Garden
RO. Mumbai, India 400 099, 2014.
Grove, California 92841, USA, 2014.
[9] Tata Chemicals Limited, Tata Swach Ultima Silver RO.
[22] Sigma-Aldrich, Sodium chloride. St. Louis, Missouri
Mumbai, India 400 001, 2014.
63103, USA, 2014.
Fixed: Varied:
m 12 kg/h mpermeate
p RR
S 3000 ppm mfeed
f
Output:
Technology Power, P
Boiling mp h fg
Best thermal mp h fg
tech. 15
p ( +Pdrive ) flow
RO
kS m
= iRT f
Pdrive p
1 RR RR
ED From, Lee et al. [40]
Figure 14. Phase I, Test 1 results (10 cell pairs, 1.6V/cell pair, 20 L/h)