MO Alarm Alam

Level Class Code


CF I1A 9
CF I1A 19
CF I2A 49
CF I2A 59
CF I2A 69
CF I2A 79
CF I2A 89
CF I2A 90
CF I2A 91
CF I2A 92
CF I2A 93
CF I2A 94
CF EC1 9
CF EC2 9
TRXC I1A 9
TRXC I1A 19
TRXC I1A 29
TRXC I1B 9
TRXC I2A 9
TRXC I2A 19
TRXC I2A 29
TRXC I2A 39
TRXC EC2 29
RX I1B 9
RX I1B 19
TX I1B 9
MCTR I2A 9
MCTR I2A 19
Alarm Name

Timing Bus Fault


HW and SW Inconsistent
Battery Backup Time Shorter Than Expected
Operating Temperature Too High, Main Load Disconnected
Cabinet Product Data Mismatch
Configuration Fault of CPRI System
DU Degraded
Ring Redundancy Lost
Fan Power Reduced
Secondary node Disconnected
Alarm Port Inconsistent Configuration
Feeder Connectivity Fault
Smoke Alarm
RBS DOOR (RBS Cabinet Door Open)
Signal Processing Fault
Reset, DXU Link Lost
Y Link Communication HW Fault
Y Link Communication Lost
TX Synthesizer Unlocked
High Frequency of Software Fault
Power Amplifier Fault
RF Loop Test Fault, Degraded RX
TS3 TRA Lost (TS Mode Is CS)
RX Cable Disconnected
RX Filter Loadfile Checksum Fault
TX Synthesizer C Unlocked
ALNA/TMA Fault
RX Path Lost on D Receiver Side
Description

The DUG has internal timing problems.


The software release does not support hardware board currently in use.
An on demand or periodic battery test has indicated that the estimated remaining battery backup time is sh
sufficient and the battery backup time is likely to be shorter than expected at the next AC power failure.
An alarm is raised when the main load is disconnected because the PDU temperature is too high. The like
The ability to keep a consistent product data view is lost and there is a mismatch between configured data
There is a configuration fault of CPRI System.
There is an internal fault in one or more TRXs/RXs/TXs.
The ring redundancy in a ring topology CPRI chain has been lost. Traffic capacity is maintained but traffic c
SCU Power connector is faulty / missing.
The DUG has no contact with the secondary node.
A configuration fault has been detected for one or more external alarm ports on an RRUS. The fault indicat
for one or more alarm ports used by more than one RBS node.
Malfunction detected in antenna system or AIR/mRRUS.
The smoke detector raises this alarm when it detects smoke in the cabinet, which can be caused by a fire.
This fault indicates that the cabinet door is open. When the door is closed, the alarm will cease within a mi
The TRX has problems with its signal processing.
Note:
The TRX has internal problems with the Y link.
See related fault.
At least one of the radio synthesizers in the TX has failed to lock to the required frequency.
Frequent software errors during execution of application software in the RUS/RRUS/AIR/mRRUS/RUG.
The data stored in the TX power amplifier database, used by software for internal configuration, is corrupte
The RF Loop test is used to detect problems with the TX and RX by sending dummy bursts between them
The speech/data frames from the BSC to the TS are missing or corrupted.
See related faults.
See related fault.
See related fault.
See related fault.
RX path lost on D receiver side of the TRX is lost. This alarm is raised if any related faults are raised on a T