Bulletin 700
Relays and Timers
Product Line Overview
Relay Selection

Bulletin 700-HA 700-HC 700-HK


Type General Purpose Relay Interposing/Isolation Relay Interposing/Isolation Relay
Blade Style Terminals,
Pin Style Terminals, Standard
Standard ON/OFF Flag Optional Pilot Light,
ON/OFF Flag Indicator,
Indicator, Electrical Retainer Clip (comes with
Electrical Schematic on Face,
Schematic on Face, Clear Socket),
Features Clear Cover for Visual
Cover for Visual Inspection, Low Switching Capacity
Inspection, Optional Push-to-
Optional Push-to-test and Push-to-Test & Manual
test and Manual Override,
Manual Override, Optional Override
Optional LED
LED
Contact Ratings
Contact Form DPDT, 3PDT DPDT, 4PDT SPDT, DPDT
Contact Type Single, Bifurcated Single Single
LOGIC

Contact Material AgNi, AgNi + Gold AgNi, AgNi + Gold AgNi, AgNi + Gold
Max. operating
10 A (DPDT)
current under 10 A 8 A (DPDT), 16 A (SPDT)
7 A (4PDT)
resistive load
Coil Ratings
AC: 6V, 12V, 24V, 48V, 110V,
120V, 208V, 230V, 240V, 277V
AC: 6V, 12V, 24V, 120V, 240V AC: 6V, 12V, 24V, 120V, 240V
Coil Voltage DC: 6V, 12V, 24V, 36V, 48V,
DC: 6V, 12V, 24V, 48V, 110V DC: 6V, 12V, 24V, 48V, 110V
60V, 80V 110V, 125V, 140V,
220V
Electrical Ratings
Pole-to-pole: 2000V Pole-to-pole: 1600V Pole-to-pole: 1500V AC
Dielectric
Contact-to-coil: 2000V Contact-to-coil: 1600V Contact-to-coil: 1500V AC
Withstand Voltage
Contact-to-frame: 2000V Contact-to-frame: 1600V Contact-to-frame: 1500V AC
Electric Service
100,000 minimum 100,000 minimum 100,000 minimum
Life (cycles)
Reference
Certifications CE, cULus, cURus, Lloyds CE, cULus, cURus, Lloyds CE, UL, UR, CSA
700-HN100, 700-HN101,
700-HN103, 700-HN128, 700-HN121, 700-HN221
Socket Cat. No(s). 700-HN125, 700-HN126,
700-HN104 700-HN122, 700-HN222
700-HN204, 700-HN205
Product Selection Page 2-6 Page 2-9 Page 2-10

2-2 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700
Relays and Timers
Product Line Overview
Relay Selection

Bulletin 700-HL 700-HL (2-Pole) 700-HP


Type Terminal Block Relays 1-Pole Terminal Block Relays 2-Pole Interposing/Isolation Relay
Ideal for PLC Interfaces,
Built-in Coil Surge Protection, Ideal for interposing isolation
Fully Assembled applications, Fully Assembled
Relay/Sockets, Standard Relay/Sockets, Standard PCB “Pin Style” Mounting,
Features
LED, Relay or Solid-state LED, Screw or Spring Clamp 5 mm Pin spacing
Output Terminals, Snap-in 1492
Optional: Leakage Current Marker Option
Suppression Solution
Contact Ratings
SPDT
Contact Form DPDT DPDT
1 N.O. (SSR)

LOGIC
Contact Type Single Single Single
Contact Material AgSnO AgSnO AgNi, AgNi + Gold
Max. operating
current under 6 A (SPDT), 2 A (SSR) 10 A 8A
resistive load
Coil Ratings
AC: 12V, 24V, 48V, 110V, AC: 24V, 48V, 110V, 120V,
120V, 230V, 240V 230V, 240V AC: 6V, 12V, 24V, 120V, 240V
Coil Voltage
DC: 12V, 24V, 48V, 125V, DC: 12V, 24V, 48V, 125V, DC: 6V, 12V, 24V, 48V, 110V
230V, 240V 230V, 240V
Electrical Ratings
Pole-to-pole: 1000V AC Pole-to-pole: 1000V AC
Dielectric Pole-to-pole: 2000V
Contact-to-coil: 4000V Contact-to-coil: 5000V
Withstand Voltage Contact-to-coil: 5000V
Contact-to-frame: 1500V Contact-to-frame: 2500V
Electric Service
100,000 minimum 100,000 minimum 100,000 minimum
Life (cycles)
Reference
Certifications CE, cURus, cULus, ABS CE, cURus, cULus CE, cULus, cURus, Lloyds
Socket Cat. No(s). — — 700-HN123
Product Selection Page 2-11 Page 2-12 Page 2-14

Rockwell Automation Visit our website: www.ab.com/catalogs 2-3


Bulletin 700
Relays and Timers
Product Line Overview
Timing Relay Selection

Bulletin 700-FE 700-FS


Type DIN Rail Timer DIN Rail Timer
Only 22.5 mm wide
8 A Contact Rating
Only 17.5 mm wide,
Multifunction or Single Function
5 A Contact Rating, Multifunction or
Features No Additional Socket Required
Single Function
Optional: Star-Delta Timing Function
No Additional Socket Required
Optional: True Off-Delay Timing Function
Optional: Hazardous Location Certification
Control Outputs:
SPDT or DPDT or
Time Limit 1 N.O. or SPDT Timed
2 N.O. + 1 common
Instantaneous
On-Delay
LOGIC

Off-Delay
One Shot
Operation Modes: 11 Different Timing Modes
Repeat Cycle-Pulse
Fleeting Off-Delay
Pulse Converter
Time Range 0.05 s…10 h 0.05s…60 h
24V AC/DC
12V DC
110…240V AC
Supply Voltage 24V…48V DC
24V…48V AC/DC
24V…240V AC
24V…240V AC
Contact Rating at
5A 8A
120V AC
Certifications CE, cULus CE, cULus
Product Selection Page 2-16 Page 2-18

2-4 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700
Relays and Timers
Product Line Overview
Control Relay Selection

Bulletin 700-K 700-M 700-CF 700-CRF


Type Miniature Control Relay Control Relay
Spring Clamp
 — — 
Terminals
Screw Terminals    —
Smallest Size, Long Smallest Size, Long
Life, Low Power Life, Low Power Mechanically Linked Contacts, Timer and
Consumption, Consumption, Latch Operations, Switch up to 690V AC and
Features
Mechanically Linked Mechanically Linked DC
Contacts, Switch up Contacts, Switch up 700S-CF for Safety Circuits
to 690V AC and DC to 500V AC and DC
4-8 Poles Double 4-8 Poles Double
Contact Form 4…12 Poles Double Break

LOGIC
Break Break
X-Mark and X-Mark and
Contact Type Cross Stamp, Bifurcated
Bifurcated Bifurcated
Contact Material Silver-Copper Silver-Copper Silver, Gold
Electrical
Max. Current AC 20 A (Relay)
15 A 15 A
Resistive 10 A (Adder Deck)
Bifurcated contacts
17V, 30 mA (700-M) 17V 10 mA (Silver)
Min. load for high contact
17V 5 mA (700-MB) 5V 3 mA (Gold)
reliability
12…600V AC 24…480V AC 12…600V AC
Coil Voltage
9…250V DC 12…220V DC 9…250V DC
Coil Voltage 85…110% AC Coils, 85…110% AC Coils, 85…110% AC Coils,
Pickup 80…110% DC Coils 80…110% DC Coils 80…110% DC Coils
Dielectric
2640V 2640V 2640V
Withstand
Reference
Electric Service
800'000 at 10 A 800'000 at 10 A 1'200'000 at 10 A
Life (cycles)
Certifications CE, cULus CE, cULus, CSA CE, cULus, CSA
DIN Rail or Panel DIN Rail or Panel
Sockets DIN Rail or Panel Mount
Mount Mount
Product Selection Page 2-22 Page 2-24 Page 2-26

Rockwell Automation Visit our website: www.ab.com/catalogs 2-5


Bulletin 700-HA
Relays and Timers
Product Selection
General Purpose Relays 700-HA

 10 A Contact Rating
 DPDT, 3PDT
 Pin Style Terminals
 Standard ON/OFF Flag Indicator
 Options: LED, Push-to-Test and Manual Override, Socket Mounted
Surge Suppressor Module, or Multifunction Timer
 Contact Choices: Standard Silver Nickel, Bifurcated Silver Nickel, or
Bifurcated with Gold Plating

Bulletin 700-HA Tube Base Relay with PIN Terminals (Single Contact) —
Mechanical ON/OFF Indicator included 1
Description Wiring Diagrams Contact Rating Coil Voltage Cat. No. ‡§
24V AC 700-HA32A24 11.00
DPDT 230V AC 700-HA32A03 11.60
2-pole
240V AC 700-HA32A2 15.60
2 Form C 10 A
Single AgNi Contact B300 24V DC 700-HA32Z24 11.00
110V DC 700-HA32Z1 12.50
700-HN100
Sockets 220V DC 700-HA32Z2 16.50
700-HN204
LOGIC

24V AC 700-HA33A24 11.60


3PDT 230V AC 700-HA33A03 12.50
3-pole
240V AC 700-HA33A2 16.30
3 Form C 10 A
Single AgNi Contact B300 24V DC 700-HA33Z24 11.60
110V DC 700-HA33Z1 13.10
700-HN101
Sockets 220V DC 700-HA33Z2 15.80
700-HN205
1 For time module and surge suppressor module, see page 2-8
 LED option: Add suffix (-4) to the selected Bulletin 700-HA relay cat. no.,
except for the 240V AC units, add (-4L).
‡ Push-to-test, manual override, and LED option: Add suffix (-3-4) to the selected Bulletin 700-HA relay cat. no.,
except for the 240V AC units, add (-3-4L).
§ Push-to-test and manual override option: Add suffix (-3) to the selected Bulletin 700-HA relay.

2-6 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-HA
Relays and Timers
Accessories
Accessories for 700-HA
Description PQ Cat. No.

Screw Terminal Tube Base Socket — Panel or DIN Rail


Mounting; Guarded Terminal Construction. 8-Pin for use with
DPDT Bulletin 700-HA Relays, -HX Timing Relays, -HT (On- 10 700-HN100 4.76
Delay) and -HRM, -HRC and -HV (Repeat Cycle) Timing Relays.
Order ten or multiples of ten

Screw Terminal Tube Base Socket — Panel or DIN Rail


Mounting; Open Style Construction. 8-Pin for use with DPDT
Bulletin 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and - 10 700-HN125 8.00
HV (Repeat Cycle) Timing Relays. Order must be for 10 sockets
or multiples of 10. No retainer clip required.

Screw Terminal Tube Base Sockets — Panel or DIN Rail


Mounting; Guarded Terminal Construction.
11-pin for use with Bulletin 700-HTA Alternating relays, -HA 10 700-HN101 5.36
relays, -HR and -HT (Off-Delay) timing relays. Order must be for
10 sockets or multiples of 10.

Screw Terminal Tube Base Sockets — Panel or DIN Rail


Mounting; Open Style Terminal Construction.
11-pin for use with Bulletin 700-HTA Alternating relays, -HA 10 700-HN126 11.90

LOGIC
relays, -HR and -HT (Off-Delay) timing relays. Order must be for
10 sockets or multiples of 10.
8-Pin Socket — Can Be Used With or Without Timing
Attachment or Surge Suppressor
Screw Terminal Tube Base Sockets — panel or DIN Rail
10 700-HN204 5.36
mounting. Guarded terminal construction. Used with DPDT
Bulletin 700-HA Relays. Order must be for 10 sockets or
multiples of 10.
11-Pin Socket — Can Be Used With or Without Timing
Module or Surge Suppressor.
Screw Terminal Tube Base Sockets — panel or DIN Rail
10 700-HN205 5.97
mounting. Guarded terminal construction.
Used with 3PDT Bulletin 700-HA relays. Order must be for 10
sockets or multiples of 10.
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-7


Bulletin 700-HA
Relays and Timers
Accessories
Accessories for 700-HA, continued
Description PQ Cat. No.
Diode Surge Suppressor 1
10 700-ADR 3.11
Voltage Range: 6…220V DC used with 700-HN204/205 socket
Diode with LED Surge Suppressor 1
10 700-ADL1R 3.15
Voltage Range: 6…24V DC used with 700-HN204/205 socket
Diode with LED Surge Suppressor 1
10 700-ADL2R 3.15
Voltage Range: 28…60V DC used with 700-HN204/205 socket
Diode with LED Surge Suppressor 1
10 700-ADL3R 3.15
Voltage Range: 110…220V DC used with 700-HN204/205socket
Diode with LED Surge Suppressor 1
10 700-AV1R 3.70
Voltage Range: 6…24V AC used with 700-HN204/205 socket
Varistor with LED Surge Suppressor 1
10 700-AV3R 3.70
Voltage Range: 110…240V AC used with 700-HN204/205 socket
RC Surge Suppressor 1
10 700-AR1 4.37
Voltage Range: 6…24V AC/DC used with 700-HN204/205 socket
RC Surge Suppressor 1
Voltage Range: 110…240V AC/DC used with 700-HN204/205 10 700-AR2 4.37
socket
On-Delay Time Module 1
Voltage Range: 12…24V
1 700-AT1 28.20
AC/DC used with 700-
HN204/205 socket
One Shot Timing Module
LOGIC

1
Voltage Range: 12…24V 1 700-AT2 28.20
AC/DC used with 700-
HN204/205 socket
Multi-Function Multi-Range Time Module 1
 Voltage range 12…240V AC 50/60 Hz and 12…240V DC, with a
voltage variation of 85…110%. Repeat accuracy of ±1%. Reset
time <50 ms. 1 700-HT3 41.30
 Choice of 8 functions
 Choice of 8 time ranges 0.1…240 h
 Use with sockets 700-HN204/205

1 Suppressors and timing modules easily plug into sockets (Cat. nos. 700-HN204 and 700-HN205). For use with
Bulletin 700-HA relays.
PQ = Package Quantity

ATTENTION: Cat. No. 700-HT3 is wired with signal “S” connected to “A1”.
See wiring diagram marked on the timer module.

2-8 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-HC
Relays and Timers
Product Selection
Interposing/Isolation Relays 700-HC

 10 A Contact Ratings
 2PDT or 4PDT
 Standard ON/OFF Flag Indicator
 Blade Style Terminals
 Choice of Standard Silver Nickel Contacts, or Silver Nickel with Gold
Plated Contacts for Low Energy Applications
 Options: LED, Push-to-Test with Manual Override Option
 Tungsten UL Approvals
4-Pole: 5A @ 24V DC
2-Pole: 10A @ 24V DC

Bulletin 700-HC Miniature Square Base with Blade Terminals


Description Wiring Diagrams Contact Rating Coil Voltage PQ Cat. No. 1
24V AC 700-HC22A24-3 7.79
2PDT
2-Pole
2 Form C 10 A
Contacts: C300
240V AC 700-HC22A2-3 8.46
10 A = AgNi R300 1
Contacts Low energy rating;
(10V, 10 mA)
700-HN103

LOGIC
Sockets 24V DC 700-HC22Z24-3 7.79
700-HN104
24V AC 700-HC24A24-3 8.25
4PDT
4-Pole 240V AC 700-HC24A2-3 8.95
4 Form C 10 A
Contacts: Low energy rating; 1
10A = AgNi (10V, 1 mA) 24V DC 700-HC24Z24-3 8.25
Contacts

Socket 700-HN104 110V DC 700-HC24Z1-3 8.95


10 700-HN103 6.06
Socket Base
10 700-HN104 5.15
1 LED option: Add suffix (-4) to the selected Bulletin 700-HC relay cat. no. except for the 240V AC units,
add (-4L).
 Push-to-test and LED option: Add suffix (-3-4) to the selected Bulletin 700-HC relay cat. no., except for the
240V AC units, add (-3-4L).
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-9


Bulletin 700-HK
Relays and Timers
Product Selection

Interposing/Isolation Relays 700-HK

 8 A/16 A Contact Ratings


 DPDT/SPDT
 Plug-in Blade Style Terminals
 Built-in Retainer Clip in Sockets
 Choice of Standard Silver Cadmium Contacts,
or Silver with Gold Plated Contacts
 Options: LED, Push-to-Test with Manual
Override Option
700-HK SPDT 700-HK DPDT

Slim Line Relay with Plug-in Quick Connect Terminations


Description Wiring Diagrams Contact Rating Coil Voltage PQ Cat. No. 1‡

24V AC 700-HK36A24 8.26


SPDT
1-Pole 240V AC 700-HK36A2 12.50
1 Form C
AgNi Contacts 16 A 1
24V DC 700-HK36Z24 6.39
LOGIC

Socket 700-HN121 110V DC 700-HK36Z1 10.30

24V AC 700-HK32A24 9.17


DPDT
2-Pole 240V AC 700-HK32A2 13.30
2 Form C
AgNi Contacts 8A 1
24V DC 700-HK32Z24 7.39

Socket 700-HN122 110V DC 700-HK32Z1 10.80

10 700-HN221 7.27
Socket Base
10 700-HN222 8.30
1 LED option: Add suffix (-4) to the selected Bulletin 700-HK relay cat. no. except for the 240V AC units, add (-4L).
 Push-to-test and LED option: Add suffix (-3-4) to the selected Bulletin 700-HC relay cat. no., except for the
240V AC units, add (-3-4L).
‡ For AgCdO contact with gold overlay: Replace “3” with “X” in cat. no. For example, if cat. no. 700-HK36A1 is
required with gold overlay, the new catalog number is 700-HKX6A1.
PQ = Package Quantity

2-10 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-HL
Relays and Timers
Product Selection
Terminal Block Relays 1-Pole

 Up to 85% panel space savings vs.


traditional relays
 DIN rail mounting
 Only 6.2 mm wide (SPDT)
 Standard LED, Reverse Polarity Protection
and Surge Protection
700-HLT… 700-HLS…
 Screw Terminals and Spring Clamp Bases

SPDT Relays
Cat. No.
Cat. No. (Spring
Assembled Devices Output (Screw Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 ♣ 700-HLT1Z24 13.30 700-HLT2Z24 13.00
24V AC/DC 10 700-HLT1U24 15.30 700-HLT2U24 15.00
110/125V AC/DC 10 ♣ 700-HLT1U1 18.60 700-HLT2U1 18.20
220…240V AC/DC 10 700-HLT1U2 18.60 700-HLT2U2 18.20
SPDT
Built-in LCSC (leakage (1 C/O);
current suppression Ith = 6A1 10  700-HLT1L1 24.60
circuit)
120V AC and 125V DC§

LOGIC
Built-in LCSC (leakage
current suppression 10  700-HLT1L2 24.60
circuit) 240V AC§

Solid State
Cat. No.
Cat. No. (Spring
Assembled Devices Output (Screw Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 ♣ 700-HLS1Z24 29.90 700-HLS2Z24 29.90
110/125V AC/DC 10 ♣ 700-HLS1U1 32.80 700-HLS2U1 32.80
220…240V AC/DC 1 N.O. 10  700-HLS1U2 32.80 700-HLS2U2 32.80
Built-in LCSC (leakage solid-
current suppression state;
10  700-HLS1L1 29.90
circuit) Ith = 2 A,
120V AC and 125V DC§ 24V DC‡
Built-in LCSC (leakage
current suppression 10  700-HLS1L2 35.40
circuit) 240V AC§
1 For gold-plated contacts: Add the letter “X” at the end of the catalog number. For example: if cat. no.
700-HLT1Z24 is required with gold plating, the new cat. no. is 700-HLT1Z24X.
 Electromechanical relay to solid-state relay interchangeability is possible.
‡ Reverse polarity on the output terminals of the solid-state relay will result in the output being "On" regardless of
the state of the input voltage.
§ Leakage current suppression up to 2.2 mA off state current.
♣ Available as EX version. Add “-EX” at the end of the cat. no. (Example: 700-HLS1Z24-EX).
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-11


Bulletin 700-HL
Relays and Timers
Product Selection
Terminal Block Relays 2-Pole

 Slim build of only 14mm wide that meets thedemand for panel
space-savings
 Standard built-in reverse DC polarityprotection ensures DC coil
devices are notdamaged if improper polarity is connected
 Separation of coil and contact terminals
 Snap in marker system
 One piece housing construction in terminal area to prevent
screwdriver blade from catching on housing seam
 10 Amp Contact Rating

DPDT Relays
Cat. No. Cat. No.
Assembled Devices Output (Screw (Spring Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 700-HLT12Z24 15.50 700-HLT22Z24 15.10
24V AC/DC DPDT 10 700-HLT12U24 17.90 700-HLT22U24 17.50
(2 C/O);
110/125V AC/DC Ith = 10 A1 10 700-HLT12U1 21.70 700-HLT22U1 21.20
220…240V AC/DC 10 700-HLT12U2 21.70 700-HLT22U2 21.20
1 For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24
with gold plated contacts is catalog number 700-HLT12Z24X. The following relays are available with the gold-
LOGIC

plated contact option: 700-HLT_2Z24, 700-HLT_2U24, 700-HLT_2U1, and 700-HLT_2U2.

2-12 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-HL
Relays and Timers
Accessories
Accessories for Terminal Block Relays
For Use
Description With PQ Cat. No.
24V DC 700-TBR24 5.34
Replacement Relays
700-HL
Order must be for 20 110/125V DC 20 1
(1-Pole) 700-TBR60 8.59
relays or multiples of 20. 220…240V DC

Replacement SSR 24V DC 700-TBS24 17.80


4-blade miniature relay
for use with 1 N.O. SSR 700-HL
110/125V DC 20
output. Order must be (1-Pole) 700-TBS60 17.80
for 20 relays or multiples 220…240V DC
of 20.
12V 700-TBR212 6.41
Replacement Relays 24V DC 1 700-TBR224 6.41
700-HL
Order must be for 20 48V 20 700-TBR248 8.91
(2-Pole)
relays or multiples of 20.
110/125V DC
1 700-TBR2110 8.91
220…240V DC
20-Way Jumper Red 700-TBJ20R 17.80
Can be cut to required Gray 700-HL 700-TBJ20G 2.90
1
length. Ith = 36 A max (1-Pole)
per 20-way jumper. Blue 700-TBJ20B 2.90
End Barrier
Used for visual

LOGIC
inspection of groups,
safe separation of 700-HL
Black 10 700-HN177 0.94
neighboring 700-HL (1- /2-Pole)
modules that end with
jumpers. Order must be
for 10 or multiples of 10.
8-Way Jumper Red 700-TBJ08R 2.90
Can be cut to required Gray 700-HL 700-TBJ08G 2.90
1
length. Ith =10 A max per (2-Pole)
8-way jumper. Blue 700-TBJ08B 2.90
Snap-in Marker Blank 1492-MS6X12 4.92
These snap-in markers www.ab.com/
have a 6 x 12 mm Standard 1492- 700-HL
100 catalogs for /
surface and snap into MS6X12 (2-Pole) information
the ejection lever for the
relay. Custom 

1 For gold-plated contacts: Add the letter “X” at the end of the catalog number. For example: if Cat. No. 700-
TBR24 is required with gold plating, the new cat. no. is 700-TBR24X. Gold-plated contacts with surcharge.
 Go to http://www.ab.com/software/termblock/index.html and download software. Create custom text, save file,
and e-mail to your local Allen-Bradley distributor.
Note: Terminal block relay bases are not sold separately.
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-13


Bulletin 700-HP
Relays and Timers
Product Selection
"Pin Style” Relays 700-HP (PCB)

 8 A Contact Ratings
 DPDT/ (2 c/o) Contacts
 Plug-in PIN Style (PCB) Terminals (5 mm Pinning)
 Choice of Standard Silver Nickel Contacts, or Silver Nickel with Gold
Plated Contacts
Options: None

700-HP

Slim Line Relay with "PIN Style" Terminations


Coil
Description Wiring Diagram Contact Rating Voltage PQ Cat. No.
DPDT 24V AC 10 700-HPX2A24 5.97
2-Pole 240V AC 10 700-HPX2A2 9.06
2 Form C
AgNi + Au 24V DC 10 700-HPX2Z24 5.97
Gold Plated
Contacts 110V DC 10 700-HPX2Z1 9.06
8A
DPDT 24V AC 10 700-HP32A24 4.20
2-Pole 240V AC 10 700-HP32A2 7.30
2 Form C
AgNi Contacts 24V DC 10 700-HP32Z24 4.20
LOGIC

Socket 700-HN123 110V DC 10 700-HP32Z1 7.30


PQ = Package Quantity

2-14 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-HP
Relays and Timers
Accessories
Accessories
Description PQ Cat. No.
Diode Surge Suppressor
10 700-ADR 3.11
Voltage Range: 6…220V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
10 700-ADL1R 3.15
Voltage Range: 6…24V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
10 700-ADL2R 3.15
Voltage Range: 28…60V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
10 700-ADL3R 3.15
Voltage Range: 110…220V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
10 700-AV1R 3.70
Voltage Range: 6…24V AC used with 700-HN123 socket
Varistor with LED Surge Suppressor
Voltage Range: 110…240V AC 10 700-AV3R 3.70
used with 700-HN123 socket
RC Surge Suppressor
10 700-AR1 4.37
Voltage Range: 6…24V AC/DC used with 700-HN123 socket
RC Surge Suppressor
10 700-AR2 4.37
Voltage Range: 110…240V AC/DC used with 700-HN123 socket
On-Delay Time
Module
Voltage Range:
1 700-AT1 28.20
12…24V AC/DC
used with 700-

LOGIC
HN123 socket
One Shot Timing
Module
Voltage Range:
1 700-AT2 28.20
12…24V AC/DC
used with 700-
HN123 socket

Screw Terminal Socket — Panel or DIN Rail Mounting


8-pin miniature socket for use with 2-pole, Bulletin 700-HP relays.
10 700-HN123 5.15
Incorporates coil and contact separation. Order must be for 10
sockets or multiples of 10.

PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-15


Bulletin 700-FE
Relays and Timers
Product Selection
Economy Timing Relays 700-FE

 Adjustable Function and Timing Range Timing Relays


 DIN Rail Mounted Without Cost of Socket
 17.5 mm wide, Multi-Function or Single Function
 Available as 1 N.O. or SPDT Contact Output, 5A
 Timing Ranges From 0.05s…10.0h
700-FE

Single-Function
This device offers you one specific timing function.
Operating Contact
Mode Output Timing Range Input Voltage Cat. No.
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FEA1SU22 41.20
settings) § 110…240V AC 50/60 Hz 1
ON-delay
0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEA3TU23 45.00
settings) ‡ 24…240V AC 50/60 Hz
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FEB1SU22 43.60
settings) § 110…240V AC 50/60 Hz 1
OFF-delay
0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEB3TU23 47.50
settings) ‡ 24…240V AC 50/60 Hz
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FED1SU22 41.20
LOGIC

settings) § 110…240V AC 50/60 Hz 1


One Shot
0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FED3TU23 45.00
settings) ‡ 24…240V AC 50/60 Hz
Fleeting OFF- 0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEE3TU23 47.50
delay settings) ‡ 24…240V AC 50/60 Hz
Flasher 0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FEF1SU22 41.20
(repeat cycle settings) § 110…240V AC 50/60 Hz 1
starting with 0.05 s…10 h (6 24V…48V AC/DC
pulse) SPDT (1 C/O) 700-FEF3TU23 45.00
settings) ‡ 24…240V AC 50/60 Hz
Pulse 0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEL3TU23 47.50
Converter settings) ‡ 24…240V AC 50/60 Hz
1 Voltage is either 24V AC 50/60 Hz or 24V DC.
‡ Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min., 0.5…10 min, 0.05…1 h, 0.5…10 h.
§ Time ranges: 0.75…15 s, 3…60 s, 0.4…8 min., 3…60 min.

2-16 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-FE
Relays and Timers
Product Selection
Economy Timing Relays 700-FE, continued
Multi-Function
This device offers you the flexibility of selecting one of 4 single timing functions.
Contact Timing
Operating Mode Output Range Input Voltage Cat. No.
24V AC/DC *
0.75 s…1 h
1 N.O. 110…240V AC 700-FEM1RU22 63.30
ON-delay, OFF-delay, (4 settings) 
50/60 Hz 1
One Shot, Flasher (repeat
cycle starting with pulse) 24V…48V AC/DC
0.05 s…10 h
SPDT (I C/O) 24…240V AC 700-FEM3TU23 65.60
(6 settings) 
50/60 Hz

Special Functions
Contact
Operating Mode Output Timing Range Input Voltage Cat. No.
2 N.O. with 0.15 s…10 min. 24V…48V AC/DC
Star-delta 700-FEY2QU23 60.90
1 Common (4 settings) ♣ 24…240V AC 50/60 Hz
1 Voltage is either 24V AC 50/60 Hz or 24V DC.

LOGIC
 Time ranges: 0.5 s…10 s, 3…60 s, 0.5 s…10 min., 3…60 min.
♣ Time ranges: (3s) 0.15…3 s, (10s) 0.5…10 s, (1m) 0.05…1 min, (10m) 0.5…10 min

Rockwell Automation Visit our website: www.ab.com/catalogs 2-17


Bulletin 700-FS
Relays and Timers
Product Selection
Electronic High Performance Timing Relays 700-FS

 Adjustable Function and Timing Range Timing Relays


 DIN Rail Mounted without Cost of Socket
 22.5 mm Wide Multifunction or Single Functions
 Available as SPDT or DPDT Contact Output, 8 A
 Timing Ranges From 0.05s…60h

700-FS

Single Function (With SPDT 1 C/O contact)


Operating Mode Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h 700-FSA3UU23 55.80
24…240V AC, 50/60 Hz
24…48V DC
0.05…1 s 700-FSA3AU23 53.50
24…240V AC, 50/60 Hz
On-delay
24…48V DC
0.5…10 s 700-FSA3CU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
0.5…10 min 700-FSA3GU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
0.05 s…60 h 700-FSB3UU23 61.50
24…240V AC, 50/60 Hz
LOGIC

24…48V DC
0.05…1 s 700-FSB3AU23 60.70
24…240V AC, 50/60 Hz
Off-delay
24…48V DC
0.5…10 s 700-FSB3CU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.5…10 min 700-FSB3GU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.05…1 s 700-FSC3AU23 60.70
24…240V AC, 50/60 Hz
On- and off-delay
24…48V DC
0.5…10 s 700-FSC3CU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.05…1 s 700-FSD3AU23 53.50
24…240V AC, 50/60 Hz
One shot
24…48V DC
0.5…10 s 700-FSD3CU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
Fleeting Off-delay 0.5…10 s 700-FSE3CU23 60.70
24…240V AC, 50/60 Hz
Flasher 24…48V DC
0.5…10 s 700-FSF3CU23 53.50
(repeat cycle starts with pulse) 24…240V AC, 50/60 Hz
Flasher 24…48V DC
0.5…10 s 700-FSG3CU23 53.50
(repeat cycle starts with pause) 24…240V AC, 50/60 Hz
24…48V DC
On-delay pulse generator 0.5…10 s 700-FSI3CU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
On-delay (pulse controlled) 0.5…10 s 700-FSJ3CU23 60.70
24…240V AC, 50/60 Hz
One shot/watch dog 24…48V DC
0.5…10 s 700-FSK3CU23 60.70
(pulse controlled) 24…240V AC, 50/60 Hz
24…48V DC
Pulse converter 0.5…10 s 700-FSL3CU23 60.70
24…240V AC, 50/60 Hz

2-18 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-FS
Relays and Timers
Product Selection
Optional Configurations, Single-Function (With SPDT 1 C/O contacts)

700–FS A 3 A U23
a b c d
a c
Operating Mode Timing Range
Code Description Code Description
A On-delay A 0.05…1 s
B Off-delay B 0.15…3 s
C On- and off-delay C 0.5…10 s
D One shot D 1.5…30 s
E Fleeting off-delay E 0.05…1 min
Flasher (repeat cycle starts F 0.15…3 min
F
with pulse) G 0.5…10 min
Flasher (repeat cycle starts H 1.5…30 min
G
with pause)
I 0.05…1 h
I On-delay pulse generator
J 0.15…3 h
On-delay (pulse
J K 0.5…10 h
controlled)
One shot/watch dog (pulse L 3.0…60 h

LOGIC
K
controlled) U 0.05 s…60 h1
L Pulse converter
d
b Input Voltage
Contact Output Code Description
Code All functions: U18 24…240V AC/DC
3 1 Changeover contact (SPDT) 24…48V DC
U23
24…240V AC 50/60 Hz
Z12 12 V DC

1 Valid for operating modes "A" and "B" only.

Single Function (With DPDT 2 C/O contacts)


Operating Mode Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h
On-delay 24…240V AC, 700-FSA4UU23 79.30

50/60 Hz
24…48V DC
0.05 s…60 h
Off-delay 24…240V AC, 700-FSB4UU23 83.00

50/60 Hz

 The timing range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-19


Bulletin 700-FS
Relays and Timers
Product Selection
Multi-Function Relays
(This device offers you the flexibility of selecting one
of 8 single timing functions.)

700-FSM

Operating Mode Contact Output Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h 1 24…240V AC 700-FSM3UU23 73.10
50/60 Hz
Multi-function timing relays (SPDT) 1 C/O 24…240V
8 Single-functions: 0.05 s…60 h 1 700-FSM3UU18 92.20
AC/DC
A, B, C, D, E, F, I, and L
ON and OFF function 346…440V AC
0.05 s…60 h 1 700-FSM3UA40 82.10
additional 50/60 Hz
(for installation and 24…48V DC
maintenance) 0.05 s…60 h 1 24…240V AC 700-FSM4UU23 88.30
Note: See connection 50/60 Hz
diagrams for further
(DPDT) 2 C/O 24…240V
description. 0.05 s…60 h 1 700-FSM4UU18 119.00
AC/DC
LOGIC

346…440V AC
0.05 s…60 h 1 700-FSM4UA40 97.40
50/60 Hz

Multi-Function Timing Relay Function and Time Range Settings

Description SPDT DPDT


Multi-function timing relays 700-FSM3U includes 10 Multi-Time Setting Range
setting functions: 0.05 s…60 h

A 10h

(A) On-Delay
(B) Off-Delay
(C) On- and Off-Delay (1 s) 0.05…1 s
(D) One shot (3 s) 0.15…3 s
(E) Fleeting Off-Delay (10 s) 0.5…10 s
(F) Flasher (repeat cycle starts with pulse) (1 min) 0.05…1 min
(I) On-Delay pulse generator (3 min) 0.15…3 min
(L) Pulse converter (10 min) 0.5…10 min
(On) ON-Function  (1 h) 0.05…1 h
(Off) OFF-Function  (3 h) 0.15…3 h
(10 h) 0.5…10 h
Note: Switch ⊗ is on DPDT relays only. When switch is (60 h) 3.…60 h
down, one contact is instantaneous and one is timed.
When switch is up, both contacts are timed.
1 The time range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.
 For installation and maintenance.

2-20 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-FS
Relays and Timers
Product Selection
Special Function Relays

700-FSH 700-FSY

Operating Mode Contact Output Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h 1 24…240V AC 700-FSH3UU23 79.00
50/60 Hz
24…48V DC
Flasher (Repeat Cycle 2 x 0.05 s…60 h
24…240V AC, 700-FSH3VU23 81.60
Starting with Pulse or (SPDT) 1 C/O (2 ranges)
50/60 Hz
Pause)
346…440V AC
0.05 s…60 h 700-FSH3UA40 88.30
50/60 Hz
2 x 0.05 s…60 h 346…440V AC
700-FSH3VA40 90.60
(2 ranges) 50/60 Hz
OFF-delay without

LOGIC
supply voltages (True (SPDT) 1 C/O 700-FSQ3QU18 99.00
OFF-delay) ‡ 24…48V DC
0.15 s…10 m  24…240V AC
OFF-delay without 50/60 Hz
supply voltages (True (DPDT) 2 C/O 700-FSQ4QU18 127.00
OFF-delay) ‡
0.5 s…10 s 700-FSY2CU23 64.40
1.5…30 s 24...48V DC 700-FSY2DU23 64.40
0.05 s…1 min. 24...240V AC 700-FSY2EU23 64.40
0.15…3 min. 50/60 Hz 700-FSY2FU23 64.40
2 N.O. + 1 0.5…10 min. 700-FSY2GU23 64.40
Star-Delta
Common 0.5 s…10 s 700-FSY2CA40 70.90
1.5…30 s 700-FSY2DA40 70.90
346…440V AC
0.05 s…1 min. 700-FSY2EA40 70.90
50/60 Hz
0.15…3 min. 700-FSY2FA40 70.90
0.5…10 min. 700-FSY2GA40 70.90
1 The timing range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.
 This timing range is selectable in four smaller ranges: 0.15 s…2.5 s, 0.5 s…10 s, 4 s…80 s, 30 s…10 min.
‡ Due to shock during shipment, the state of the contacts should be verified before initial use.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-21


Bulletin 700-K
Relays and Timers
Product Selection
Miniature Control Relays 700-K

 IEC Compact Industrial Relay


 IP2X Finger Protection
 Bifurcated Contacts for low level signals
 Optional integrated coil protection diode

AC Coil Voltage Control Relays


AC-12 AC-15 (A600) Contacts
Ie [A] Ie [A] PQ
40 °C 60 °C 24/48V 230V 400V 500V 690V N.O. N.C. 1 Cat. No.
4 0 1 700-K40E-⊗ 26.00
3 1 1 700-K31Z-⊗ 26.00
10 6 6 3 1.6 1.4 0.8
2 2 1 700-K22Z-⊗ 26.00
1+1L 1+1L 1 700-KL22Z-⊗ 32.50
LOGIC

DC Coil Voltage Control Relays


AC-12 AC-15 (A600) Contacts
Ie [A] Ie [A] PQ
40 °C 60 °C 24/48V 230V 400V 500V 690V N.O. N.C. 1 Cat. No.
4 0 1 700-K40E-⊗ 28.60
3 1 1 700-K31Z-⊗ 28.60
10 6 6 3 1.6 1.4 0.8
2 2 1 700-K22Z-⊗ 28.60
1+1L 1+1L 1 700-KL22Z-⊗ 34.50
1 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-KFM.
 1L = Late break N.C./early make N.O.
⊗ The Cat. No. as listed is incomplete. Select a standard Coil Voltage Code from the table below to complete
the Cat. No. Example: 230V, 50/60 Hz: Cat. No. 700-K40E-⊗ becomes Cat. No. 700-K40E-KF.

⊗ Coil Voltage Codes for AC and DC Control


AC Control DC Control
Code Description Code Description
KJ 24V 50/60 Hz ZJ 24V DC
KY 48V 50/60 Hz DJ 24V DC with integrated diode
D 110V 50 Hz ZD 110V DC
KF 230V 50/60 Hz ZA 220V DC
KN 400V 50/60 Hz
For other voltages visit our website or consult your local sales office.

2-22 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-K
Relays and Timers
Accessories
Auxiliary Contact Blocks
PQ
N.O. N.C. 1 Cat. No.
0 2 1 100-KFA02E 5.80
1 1 1 100-KFA11E 5.80
Front-mounted auxiliary contacts
Auxiliary Contact Blocks 2 0 1 100-KFA20E 5.80
2- and 4-pole versions 0 4 1 100-KFA04E 10.80
Choice of contact configurations
Snap on, no tools required 1 3 1 100-KFA13E 10.80
Electronic-compatible bifurcated contacts 2 2 1 100-KFA22Z 10.80
for signals down to 15V/2 mA
3 1 1 100-KFA31Z 10.80
4 0 1 100-KFA40E 10.80
1 May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFC02M.

Control Modules
Description PQ Cat. No.
Mechanical Interlock

LOGIC
For interlocking of two adjacent contactors
No added width to contactor assembly
1 100-KMCH 4.70
Front mount Plug-In type
Optional auxiliary contact blocks and suppressor modules
mount onto the interlock
24…48V AC 11 100-KFSC50
R-C Suppressor 110…280V AC 11 100-KFSC280 9.70
380…480V AC 11 100-KFSC480
12…55V AC /
Surge Suppressor 11 100-KFSV55
12…77V DC
Plug-in Type
Limits surge voltage MOV Suppressor 56…136V AC / 11 100-KFSV136 10.30
on coil drop-off 78…180V DC
137…277V AC /
11 100-KFSV277
181…250V DC
Diode
12…250V DC 11 100-KFSD250 5.80
Suppressor
1 May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-23


Bulletin 700-M
Relays and Timers
Product Selection
Miniature Control Relays 700-M

 IEC Compact Industrial Relay


 700-M Standard Contacts (10 A)
 700-MB Bifurcated Contacts For Low Energy Loads
 Positively Guided/Mechanically Linked Contacts Per IEC 60947-5-1
on All 700-M Relays

AC Coil Voltage Control Relays 1

AC-1 AC-15 Contacts


Ie [A] Ie [A]
40 °C 400V 500V N.O. N.C. Cat. No.
2 2 700-M220⊗S 26.00
3 1 700-M310⊗S 26.00
16 2.5 1.25
4 0 700-M400⊗S 26.00
1+1L 1+1L 700-MZ220⊗S 32.80

DC Coil Voltage Control Relays 1

AC-1 AC-15 Contacts


LOGIC

Ie [A] Ie [A]
40 °C 400V 500V N.O. N.C. Cat. No.
2 2 700DC-M220⊗S 28.60
3 1 700DC-M310⊗S 28.60
16 2.5 1.25
4 0 700DC-M400⊗S 28.60
1+1L 1+1L 700DC-MZ220⊗S 34.90
1 Mechanically Linked Contacts — Summary:
700-M, 700-MB, 700DC-M, and 700DC-MB relays are positively guided for 4 main poles. Restrictions apply
when using auxiliary contacts.
 10-packs can be ordered for the following voltage codes: A1, A2, A24, Z24, D24. To order a 10-pack, specify
quantity in multiples of 10 and drop the final "S" from the catalog number.

⊗ Coil Voltage Codes for AC and DC Control


AC Control DC Control
Code Description Code Description
A24 24V 50/60 Hz Z24 24V DC
A48 48V 50/60 Hz D24 24V DC with integrated diode
A1 110V 50 Hz Z11 110V DC
KF 230V 50/60 Hz Z2 220V DC
A3 400V 50 Hz
For other voltages visit our website or consult your local sales office.

2-24 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-M
Relays and Timers
Accessories
Accessories for 700-M
For Use
Description Type With Cat. No.
2 N.C. 700-M400 1 195-MA02 5.89
Auxiliary Contact Blocks
for Front Mounting 1 N.O./1 N.C. 700-M400 1 195-MA11 5.89
 2- and 4-pole 1 N.O./3 N.C. 700-M400 1 195-MA13 10.80
 Quick and easy mounting
700-M400,
without tools
-M310,
 Electronic-compatible H- 2 N.O. 1 195-MA20 5.89
-M220,
contacts (700-MB…)
-MZ220
 Contacts themselves in
auxiliary contact block 4 N.C. 700-M400 1 195-MA04 10.80
positively guided 2 N.O./2 N.C. 700-M400 1 195-MA22 10.80
 Types with the same
functions with several 700-M400,
connection numbering -M310,
4 N.O. 1 195-MA40 10.80
variants -M220,
-MZ220
0.3…3 s On-Delay,
110…250V AC or 1 196-MT3S 47.00
Solid-State Timing DC
Element 1…30 s On-Delay,
110…250V AC or 1 196-MT30S 47.00
100-M
DC
110V AC 1 196-MTSDA1 80.40
1

LOGIC
Star-Delta Timer 220V AC 196-MTSDA2 80.40
48V 1 196-MTSDA3 80.40
35 mm DIN Rail Mounting Adapter
For easy mounting of timer modules on standard DIN Rail (EN 1 196-MTM 1.64
50 022-35) and G-Rail
24…48V AC 1 199-MSMNA48 9.71
R-C Suppressor 110…280V AC 100M 1 199-MSMNA280 9.71
380…480V AC 1 199-MSMNA480 9.71
12…55V
1 199-MSMV4 10.30
AC/12…77V DC
56…136V
MOV Suppressor 100-M 1 199-MSMV5 10.30
AC/78…162V DC
137…277V
1 199-MSMV6 10.30
AC/181…350V DC
Diode Suppressor 12…250V DC 100-M 1 199-MSMD2 5.78
1 Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-25


Bulletin 700-CF/CRF
Relays and Timers
Product Selection
Control Relays 700-CF
 IEC Industrial Relays (Finger Safe Design)
 Positively-Guided/Mechanically-Linked Contacts per
IEC 60947-5-1 Annex L on Main and Auxiliary Contacts
 Gold Plated, Bifurcated Version for Low Level Switching
Applications
 Master Control Relay Version rated 15 A (AC-15)
 Solid-State and Pneumatic Timing Modules
 4…10 Poles
 12…600V Coils 700-CF 700-CRF

4-Pole AC Coil Voltage (Screw Terminals)


Standard Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No. 1
2 2 700-CF220⊗ 29.60
20 20 10 6 2.5 3 1 700-CF310⊗ 29.60
4 0 700-CF400⊗ 29.60
1 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CF220KFM).
LOGIC

Bifurcated Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No. 
2 2 700-CFB220⊗ 29.60
20 20 10 6 2.5 3 1 700-CFB310⊗ 29.60
4 0 700-CFB400⊗ 29.60
 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CFB220KFM).

4-Pole AC Coil Voltage (Spring Clamp Terminals)


AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No.
2 2 700-CRF220⊗ 31.10
20 20 10 6 2.5 3 1 700-CRF310⊗ 31.10
4 0 700-CRF400⊗ 31.10

⊗ The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table on page 2-27 to
complete the Cat. No. Example: Cat. No. 700-CF220⊗ becomes Cat. No. 700-CF220KF for 230V,
50/60 Hz.

2-26 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-CF/CRF
Relays and Timers
Product Selection
4-Pole DC Coil Voltage (Screw Terminals)
Standard Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No. 1
2 2 700-CF220⊗ 58.00
20 20 10 6 2.5 3 1 700-CF310⊗ 58.00
4 0 700-CF400⊗ 58.00
1 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CF220ZJM).

Bifurcated Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No. 
2 2 700-CFB220⊗ 32,50
20 20 10 6 2.5 3 1 700-CFB310⊗ 32,50
4 0 700-CFB400⊗ 32,50

 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CFB220ZJM).

LOGIC
Discount Schedule PRO

4-Pole DC Coil Voltage (Spring Clamp Terminals)


AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No.
2 2 700-CRF220⊗ 58.90
20 20 10 6 2.5 3 1 700-CRF310⊗ 58.90
4 0 700-CRF400⊗ 58.90

⊗ Coil Voltage Codes for AC and DC Control


AC Control DC Control
Code Description Code Description
KJ 24V 50/60 Hz ZJ 24V DC
KY 48V 50/60 Hz DJ 24V DC with integrated diode
KD 110V 50/60 Hz ZY 48V DC
KF 230V 50/60 Hz ZD 110V DC
KN 400V 50/60 Hz ZA 220V DC
M 500V 50 Hz
For other voltages visit our website or consult your local sales office.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-27


Bulletin 700-CF/CRF
Relays and Timers
Accessories
Auxiliary Contacts for 700-CF, 700-CRF 1

For Use
Description N.O. N.C. With Cat. No.
Auxiliary Contacts with Screw Terminals 
Auxiliary Contact Blocks for Front 0 2 100-FA02 6.37
Mounting 1 1 100-FA11 6.37
2- and 4-pole
Quick and easy mounting without 2 0 100-FA20 6.37
tools
Electronic-compatible contacts
down to 17V, 5 mA 2 2 100-FA22 11.40
Mechanically linked performance
between N.O. and N.C. poles and to 700-CF
the main contactor poles (except for 3 1 100-FA31 11.40
L types)
Models with equal function with
several terminal numbering choices
1L = Late break N.C./early make 4 0 100-FA40 11.40
N.O.
Bifurcated version for switching
1+1L 1+1L 100-FAL22 11.40
down to 5V, 3 mA ‡
Auxiliary Contacts with Spring Clamp Terminals
Auxiliary Contact Blocks for Front 0 2 100-CRFA02 6.68
Mounting 1 1 100-CRFA11 6.68
2- and 4-pole
Quick and easy mounting without 2 0 100-CRFA20 6.68
LOGIC

tools
Electronic-compatible contacts
down to 17V, 5 mA 2 2 100-CRFA22 12.10
Mechanically linked performance
between N.O. and N.C. poles and to 700-CRF
the main contactor poles (except for 3 1 100-CRFA31 12.10
L types)
Models with equal function with
several terminal numbering choices
1L = Late break N.C./early make 4 0 100-CRFA40 12.10
N.O.
Bifurcated version for switching
1+1L 1+1L 100-CRFAL22 12.10
down to 5V, 3 mA ‡
1 Max. number of auxiliary contacts that may be mounted:
AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side,
4 N.C. front or side, 6 total.
DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side,
4 N.C. front or side, 4 total.
 May be ordered in package quantities of 10. Add letter M to the end of the cat. no. (Example: 100-FA02M).
‡ Selection data, see catalog A11_ or consult your local sales office.

Additional Accessories for 700-CF, 700-CRF see page 1-29

2-28 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-S
Solid State Devices
Product Line Overview
Solid State Devices 700-SH, -SE, -SC

Bulletin 700-SH 700-SE 700-SC


Type Hockey Puck Flat Pack Miniature, Ice Cube Socketed
Compatible w/700-HN103 or
Panel/DIN Mount, High
128 socket, LED Status &
Features Current, Protective Cover, Panel/DIN Mount, Low Profile
Zero-cross AC Switching
LED Status
Options
AC (47…63
Load Type AC (47…63 Hz) AC (47…63 Hz) DC
Hz)
3…52.8V DC
Load Voltage
19…264V AC, 180…528V AC 75…264V AC 75…264V AC or 3…125V
Range
DC
3A @ 48V DC
Load Current Max.
6 A/40 A 1 5 A/20 A 1 3A or 2A @ 110V
(Continuous)
DC
10 mA @

LOGIC
200V AC, 5
Max Leakage 5 mA @ 100V, 10 mA @ 200V, 5 mA @ 100V
5 mA @ 100V, 10 mA @ 200V mA @ 50V DC
Current to Load 20 mA @ 400V AC
or 0.1mA @
100V DC
Zero Cross Load
Yes Yes (optional) Yes (optional) N/A
Switching
Equivalent
Electromechanical 1 N.O. 1 N.O. 1 N.O.
Relay Contact Form A Form A Form A
Arrangement
5…24V DC,
Rated Control 5…24V DC, 100…120V AC, 100…110V
5V DC, 12V DC, 24V DC 5...24V DC
(Input) Voltage 200…240V AC AC, 200/220V
AC
Yes (optional
LED Indicator Yes No Yes (optional)
for 48V DC)
Panel w/o heat sink, Panel or Panel w/o heat sink, Panel or
Mounting Method Panel or DIN w/socket
DIN w/heat sink DIN w/heat sink
Dielectric Strength 2500V AC, 50/60 Hz, 1 min. 2000V AC, 50/60 Hz, 1 min. 1500V AC, 50/60 Hz, 1 min.
Certification cURus, CE , TÜV 1 cURus, CE, TÜV cURus, CE, VDE
Max. Ambient
Operating -30…80°C (no condensation) -30…80°C (no condensation) -30…80°C (no condensation)
Temperature
Product Selection Page 2-31 Page 2-32 Page 2-33
1 With heat sink.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-29


Bulletin 700-S
Solid State Devices
Product Line Overview
Solid State Devices 700-SA, -SK

Bulletin 700-SA 700-SK


Type Tube Base, Socketed Slim Line, Socketed
Compatible w/700-HN100,
125,108, and 204 socket, Compatible w/700-HN121 socket. Supports Input (sensor)
Features
LED status, zero-cross module or Output (SSR) module
switching
Output Module Input Module
AC
Load Type DC AC AC (47…63
(47…63 Hz) DC DC
(47…63 Hz) Hz)
4 … 60V DC,
Load Voltage 75 … 264V Field Input: Field Input:
75…264V AC 3 …125V DC 40 … 200V
Range AC 60… 264V AC 6.6… 32V DC
DC
Supply Supply
Load Current Max. 2A @ 60V,
5A 3A 2A Current: 0.1 Current: 0.1
(Continuous) 1.5A @ 200V
… 100 mA … 100 mA
LOGIC

5 mA @ 100V,
Max Leakage
10 mA @ 5 mA @ 125V 1.5 mA 1 mA 5 μA 5 μA
Current to Load
200V
Zero Cross Load
Yes N/A Yes (optional) N/A No N/A
Switching
Equivalent
Electromechanical 1 N.O. 1 N.O.
Relay Contact Form A Form A
Arrangement
Rated Control
5…24V DC 5 … 24 V DC 5 … 24 V DC 5 … 24V DC 5 … 24V DC
(Input) Voltage
LED Indicator Yes Yes
Mounting Method Panel or DIN w/socket Panel or DIN w/socket
Dielectric Strength 1500V AC, 50/60 Hz, 1 min. 4000V AC, 50/60 Hz, 1 min.
Certification cURus, CE, VDE cURus, CE, TÜV
Max. Ambient
-30 … 80°C, (no
Operating -30 … 80°C (no condensation)
condensation)
Temperature
Product Selection Page 2-35 Page 2-36

2-30 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-SH
Solid State Devices
Product Selection
Hockey Puck Relays for DIN Rail Mounting 700-SH

700-SH

Output (Load) Max.


Input-to-Output Zero Continuous Current Rated Input
Isolation Cross LED and Rated Voltage Control
Method Function Indicator Range 1 Voltage Cat. No.
Phototriac 5…24V DC 700-SH05GZ25 19.30
5 A @ 24…240V AC
Yes Yes 100…120V AC 700-SH05GA12 24.50
Photocoupler (47…63 Hz)
200…240V AC 700-SH05GA22 24.50
Phototriac 5…24V DC 700-SH10GZ25 18.10
10 A @ 24…240V AC
100…120V AC 700-SH10GA12 22.80
(47…63 Hz)
Yes Yes 200…240V AC 700-SH10GA22 22.80
Photocoupler

LOGIC
10 A @ 200…480V AC
5…24V DC 700-SH10HZ25 48.40
(47…63 Hz)
Phototriac 5…24V DC 700-SH25GZ25 23.40
25 A @ 24…240V AC
100…120V AC 700-SH25GA12 27.90
Photocoupler (47…63 Hz)
Yes Yes 200…240V AC 700-SH25GA22 27.90
25 A @ 200…480V AC
Photocoupler 5…24V DC 700-SH25HZ25 48.40
(47…63 Hz)
Phototriac 5…24V DC 700-SH40GZ25 43.50
40 A @ 24…240V AC
100…120V AC 700-SH40GA12 52.30
(47…63 Hz)
Yes Yes 200…240V AC 700-SH40GA22 52.30
Photocoupler
40 A @ 200…480V AC
5…24V DC 700-SH40HZ25 65.40
(47…63 Hz)
1 Maximum load current when mounted on the appropriate heat sink.

Accessories
Description Cat. No.
700-S10 14.90

Heat Sink— Panel or DIN Rail Mount 700-S20 19.20

700-S30 24.50

Rockwell Automation Visit our website: www.ab.com/catalogs 2-31


Bulletin 700-SE
Solid State Devices
Product Selection
Flat Pack Relays for DIN Rail Mounting 700-SE

700-SE

Input-to- Output (Load) Max.


Output Zero Continuous Current Rated Input
Isolation Cross LED and Rated Voltage (Control)
Method Function Indicator Range 1 Voltage Cat. No.
5V DC 700-SE05GZZ05 15.60
5 A @ 100…240V AC
12V DC 700-SE05GZZ12 15.60
(47…63 Hz)
24V DC 700-SE05GZZ24 15.60
5V DC 700-SE10GZZ05 16.70
10 A @ 100…240V AC
Yes No 12V DC 700-SE10GZZ12 16.70
(47…63 Hz)
24V DC 700-SE10GZZ24 16.70
LOGIC

5V DC 700-SE20GZZ05 20.10
20 A @ 100…240V AC
12V DC 700-SE20GZZ12 20.10
(47…63 Hz)
24V DC 700-SE20GZZ24 20.10
Phototriac
5V DC 700-SE05GNZ05 16.40
5 A @ 100…240V AC
12V DC 700-SE05GNZ12 16.40
(47…63 Hz)
24V DC 700-SE05GNZ24 16.40
5V DC 700-SE10GNZ05 18.00
10 A @ 100…240V AC
No No 12V DC 700-SE10GNZ12 18.00
(47…63 Hz)
24V DC 700-SE10GNZ24 18.00
5V DC 700-SE20GNZ05 21.10
20 A @ 100…240V AC
12V DC 700-SE20GNZ12 21.10
(47…63 Hz)
24V DC 700-SE20GNZ24 21.10
1 Maximum load current when mounted on the appropriate heat sink.

Accessories
Description Cat. No.
700-S10 14.90

Heat Sink— Panel or DIN Rail Mount 700-S20 19.20

700-S30 24.50

2-32 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-SC
Solid State Devices
Product Selection
Ice Cube Relays with Blade Style Terminals 700-SC

700-SC

Input-to- Output (Load) Max.


Output Zero Continuous Current Rated Input
Isolation Cross LED and Rated Voltage (Control)
Method Function Indicator Range Voltage Cat. No.
3 A @ 100…240V AC
5…24V DC 700-SCZY3Z25 21.30
(47…63 Hz)
Photocoupler Yes
2 A @ 100…240V AC 100/110V AC 700-SCZY2A1 22.40
(47…63 Hz) 200/220V AC 700-SCZY2A2 22.40
Yes
3 A @ 100…240V AC
Phototriac No 24V DC 700-SCTY3Z24 21.30
(47…63 Hz)
Not
3 A @ 4…48V DC 5…24V DC 700-SCNY3Z25 21.30

LOGIC
Photocoupler Applicable
Yes 3 A @ 100…240V AC 4…24V DC 700-SCZN3Z26 21.30
Phototriac No (47…63 Hz) 24V DC 700-SCTN3Z24 21.30
No
Not 3 A @ 4…48V DC 4…24V DC 700-SCNN3Z26 21.30
Photocoupler
Applicable 2 A @ 5…110V DC 5…24V DC 700-SCNN2Z25 22.40

Rockwell Automation Visit our website: www.ab.com/catalogs 2-33


Bulletin 700-SC
Solid State Devices
Accessories
Accessories for 700-SC
Description PQ Cat. No.

Screw Terminal Socket — Panel or DIN Rail Mounting;


Guarded Terminal Construction. Ith = 10 A per pole. 14-
10 700-HN103 6.06
Blade miniature socket for use with Bulletin 700-HC Relays.
Order must be in ten or multiples of ten

Screw Terminal Socket – Panel or DIN Rail Mounting.


Guarded Terminal Construction Ith = 10 A per pole. 14-
blade miniature socket for use with Bulletin 700-HC relays.
10 700-HN104 5.15
This socket has coil and contact separation as well as the
ability to plug in optional plug in modules (700-A**
accessories: LED, Surge Suppression, Timing Modules)

Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -


HN128 Sockets with 700-HC Relays and Cat. Nos. 700-
HN116 Sockets with Bulletin 700-HF DPDT Relays 1 10 700-HN114 0.28
Secures relay in socket. Order must be for 10 clips or
multiples of 10.
On-Delay Time Module
Voltage Range: 12…24V AC/DC used with 700-HN104 1 700-AT1 28.20
socket
One Shot Timing Module
Voltage Range: 12…24V AC/DC used with 700-HN104 1 700-AT2 28.20
socket
LOGIC

1 Series B retainer clip must be used with Bulletin 700-SC


PQ = Package Quantity

2-34 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 700-SA
Solid State Devices
Product Selection
Tube Base Relays with Pin Terminals 700-SA

700-SA

Input-to- Output (Load) Max.


Output LED Continuous Current Rated Input
Isolation Zero Cross Indicat and Rated Voltage (Control)
Method Function or Range Voltage Cat. No.
5 A @ 100…240V AC
Yes 700-SAZY5Z25 29.90
(47…63 Hz)
Photocoupler Yes 5…24V DC
Not
3 A @ 5…110V DC 700-SANY3Z25 37.30
Applicable

LOGIC
Accessories
Description PQ Cat. No.

Screw Terminal Tube Base Socket — Panel


or DIN Rail Mounting; Guarded Terminal 10 700-HN100 4.76
Construction. Order ten or multiples of ten

Retainer Clip for Cat. Nos. 700-HN100, -


HN101, -HN200, -HN201, -HN204, and -HN205
Sockets with Bulletin 700-HA Relays 10 700-HN157 0.43
Secures relay in socket. Order must be for 10
clips or multiples of 10.

8-Pin Socket—Screw Terminal Tube Base


Sockets — panel or DIN Rail mounting. Order 10 700-HN204 5.36
must be for 10 sockets or multiples of 10.

PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-35


Bulletin 700-SK
Solid State Devices
Product Selection
"Slim Line" Relays with Plug-in Quick Connect Terminals 700-SK
 High response speed models
 Input sensor module to allow high voltage 100…240V AC or
12…24V DC sensor
 Interface to low voltage (Logic) device such as a PC output
module for typical SSR applications
 LED indicator
 Input modules and output modules can be used with the
700-HN121 socket 700-SK

Input/Sensor Module

Input-to- Logic Level


Output Response
Isolation LED Frequenc Supply Supply Rated Input
Method Indicator y Voltage Current Sensor Voltage Cat. No.
10 Hz 4…32V 100…240V AC 1 700-SKICA18 24.00
Photocoupler Yes 0.1…100 mA
1 kHz DC 12…24V DC 700-SKICZ24 18.80
1 47…63 Hz

Output/SSR Module
LOGIC

Input-to- Output (Load) Max.


Output Zero Continuous Current Rated Input
Isolation Cross LED and Rated Voltage Control
Method Function Indicator Range Voltage Cat. No.
Yes 700-SKOZ2Z25 22.20
Phototriac 2 A @ 100…240V AC 1
No 700-SKON2Z25 22.50
Yes 5…24V DC
Not 2 A @ 5…48V DC 700-SKOC2Z25 21.00
Photocoupler
Applicable 1.5 A @ 48…200V DC 700-SKOC1Z25 24.40
1 47…63 Hz

Accessories
Description PQ Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting
5-blade miniature socket with 10 A rating for use with 1-
pole, Bulletin 700-HK relays. Accepts forked lug 10 700-HN121 7.27
conductors. Socket includes a retainer clip. Order must
be in multiples of ten.
PQ = Package Quantity

2-36 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 900-TC
Temperature Controllers
Product Line Overview
Temperature Controllers 900-TC

Bulletin 900-TC8 900-TC16 900-TC32


Dimensions:
Height 96 mm 48 mm 24 mm
Width 48 mm 48 mm 48 mm
Depth 78 mm 78 mm 100 mm
Sample Rate 250 or 500 ms 500 ms
Indication Accuracy ±0.5% PV ±1 digit max.
Heating/Cooling
  
Control Mode
Control Method ON/OFF or 2-PID (auto-tune and self-tune) with time proportioning ON/OFF output
• Thermocouple Input
• Platinum Resistance Temperature Sensor
Inputs • Analog Input 0…20 mA, 4…20 mA / 1…5V DC, 0…5V DC, 0…10V DC, 0…50mV DC
1

LOGIC
• Non-Contact Temperature Sensor
• Relay Output (electromechanical) • Relay Output
• Voltage Output for Solid-State Relay (electromechanical)
Control Output 1
• Triac Output (AC only) • Voltage Output for
• Analog Output 4…20 mA and 0…20 mA Solid-State Relay
• Voltage Output for • Voltage Output for Solid-
Control Output 2 Solid-State Relay State Relay (with option —
• Triac Output (AC only) unit)
Max. Number of Alarms 3 2 (with option unit) 1
RS-232C
Communications  (with option unit) — —
Function
RS-485
Communications  (with option unit)  (with option unit) 
Function
Event Input  (with option unit)  (with option unit) —
Run/Stop via Keypad or
  Keypad
Interrupts
Multiple SP Selection
via   Keypad
Keypad or Interrupts
Heater Burnout and
  —
Heater Short Alarm
Product Selection Page 2-38 Page 2-39 Page 2-40
1 900-TC32 only available with 0…50 mV DC.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-37


Bulletin 900-TC
Temperature Controllers
Product Selection
Temperature Controllers 900-TC8

Supports
Heater Burnout
(Open) and
Power Max. No. Heater
Supply of Alarms Control Control Short-Circuit
Voltage Supported Output 1 Output 2 Alarm Cat. No.
Input Type: Thermocouple or RTD
— No 900-TC8RGTZ25 318.00
— Yes (1-Phase) 900-TC8RGTH1Z25 330.00
Relay Voltage (for
No 900-TC8RVGTZ25 355.00
driving SSR)
— Yes (3-Phase) 900-TC8RGTH3Z25 350.00
— No 900-TC8VGTZ25 318.00
— Yes (1-Phase) 900-TC8VGTH1Z25 329.00
100…
3 Voltage (for Triac No 900-TC8VYGTZ25 355.00
LOGIC

240V AC
driving SSR) Voltage (for
No 900-TC8VVGTZ25 355.00
driving SSR)
— Yes (3-Phase) 900-TC8VGTH3Z25 350.00
— No 900-TC8ACGTZ25 350.00
0...20 or 4...20 mA Triac No 900-TC8ACYGTZ25 382.00
Analog Output Voltage (for
No 900-TC8ACVGTZ25 382.00
driving SSR)
— No 900-TC8RGTU25 308.00
Relay
— Yes (1-Phase) 900-TC8RGTH1U25 318.00
24V Voltage (for — No 900-TC8VGTU25 308.00
3
AC/DC driving SSR) — Yes (1-Phase) 900-TC8VGTH1U25 318.00
0...20 or 4...20 mA
— No 900-TC8ACGTU25 350.00
Analog Output
Input Type: Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC
Relay — Yes (1-Phase) 900-TC8RABH1Z25 340.00
Relay — No 900-TC8RABZ25 330.00
Voltage (for
— Yes (1-Phase) 900-TC8VABH1Z25 340.00
driving SSR)
100… Voltage (for
3 — No 900-TC8VABZ25 330.00
240V AC driving SSR)
Voltage (for
Triac No 900-TC8VYABZ25 366.00
driving SSR)
0...20 or 4...20 mA
— No 900-TC8ACABZ25 361.00
Analog Output
A current transformer (CT) is not provided with the unit.
When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs can be
used as the heating or cooling output or heater burnout alarm.

2-38 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 900-TC
Temperature Controllers
Product Selection
Temperature Controllers 900-TC16

Supports Heater
Power Max. No. of Burnout (Open) and
Supply Alarms Heater Short-Circuit
Voltage Supported Control Output  Alarm Cat. No.
Input Type: Thermocouple or RTD
Relay Yes 1 900-TC16RGTZ25
Triac Yes 1 900-TC16YGTZ25 149,00
100… Voltage (for driving
2 Yes 1 900-TC16VGTZ25 143,00
240V AC SSR)
0...20 or 4...20 mA
No 900-TC16ACGTZ25 174,00
Analog Output
Relay Yes 1 900-TC16RGTU25 136,00
Voltage (for driving
24V Yes 1 900-TC16VGTU25 136,00
2 SSR)
AC/DC

LOGIC
0...20 or 4...20 mA
No 900-TC16ACGTU25
Analog Output
Input Type: Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC
Relay Yes 1 900-TC16RABZ25 143,00
Triac Yes 1 900-TC16YABZ25 149,00
100… Voltage (for driving
240V AC Yes 1 900-TC16VABZ25 143,00
SSR)
0...20 or 4...20 mA
No 900-TC16ACABZ25 187,00
2 Analog Output
Relay Yes 1 900-TC16RABU25 143,00
Voltage (for driving
24V Yes 1 900-TC16VABU25 143,00
SSR)
AC/DC
0...20 or 4...20 mA
No 900-TC16ACABU25 187,00
Analog Output
A current transformer (CT) is not provided with the unit.
When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs can be
used as the heating or cooling output or heater burnout alarm.
1 To implement the single-phase or three-phase heater burnout and heater short alarm function, an option module
must be inserted into the 900-TC16 controller. For a list of 900-TC16 option modules, refer to the Option Units
table. The heater burnout and heater short alarm is available by mounting the appropriate option module into
any 900-TC16 controller that supports (yes) the heater burnout (open) or heater short-circuit feature.
 The Bulletin 900-TC16 can have a second ON/OFF control output (SSR) by adding an option unit to the
controller. Refer to Option Units table.
Discount Schedule RAA

Rockwell Automation Visit our website: www.ab.com/catalogs 2-39


Bulletin 900-TC
Temperature Controllers
Product Selection
Temperature Controllers 900-TC32

Max. No. of
Power Supply Alarms Control Output RS485
Voltage Supported Type Communication Port Cat. No.
Controller with Thermocouple Support
Relay 900-TC32RTZ25 204.00
100…
1 Voltage (for driving No
240V AC 900-TC32VTZ25 204.00
SSR)
Relay 900-TC32RTU25 204.00
24V AC/DC 1 Voltage (for driving No
900-TC32VTU25 204.00
SSR)
Relay 900-TC32CRTZ25 247.00
100…
No Voltage (for driving Yes
240V AC 900-TC32CVTZ25 247.00
SSR)
Relay 900-TC32CRTU25 236.00
24V AC/DC No Voltage (for driving Yes
LOGIC

900-TC32CVTU25 236.00
SSR)
Controller with Platinum RTD Support
Relay 900-TC32RPZ25 204.00
100…
1 Voltage (for driving No
240V AC 900-TC32VPZ25 204.00
SSR)
Relay 900-TC32RPU25 204.00
24V AC/DC 1 Voltage (for driving No
900-TC32VPU25 204.00
SSR)
Relay 900-TC32CRPZ25 247.00
100…
No Voltage (for driving Yes
240V AC 900-TC32CVPZ25 247.00
SSR)
Relay 900-TC32CRPU25 236.00
24V AC/DC No Voltage (for driving Yes
900-TC32CVPU25 236.00
SSR)
If the heating/cooling function is used, ALM1 will be used for the cooling control output and so the alarm output
relay will not be available.
Cat. Nos. with a C designator (e.g., Cat. No. 900-TC32C___) include RS-485 communications, but do not have an
alarm (or cooling) output.

2-40 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 900-TC
Temperature Controllers
Product Selection
Option Units (Bulletins 900-TC8 and 900-TC16 - Only One Option Unit per Controller)
The unit provides communications or event input functionality.

Bulletin No. Name Function Cat. No.


RS-232C communications ® 900-TC8232  138.00
Communications Unit
900-TC8 RS-485 communications 900-TC8COM  128.00
Event Input Unit Event input  900-TC8EIM 128.00
RS-485 communications with
Communications and 1-
single-phase heater burnout
Phase Heater Burnout Unit 900-TC16NCOM 79.60
(open) and heater short-
and Heater Short
circuit failure detection 
Event Input with single-phase
Event Input Unit with 1-Phase
heater burnout (open) and
Heater Burnout and Heater 900-TC16NEIM 58.40
heater short-circuit failure
Short
detection 
Event Input Unit Event Input  900-TC16NACEIM 37.10
Communications Unit RS-485 communications 900-TC16NACCOM 58.40
900-TC16 RS-485 communications with
Communications and 3-
3-phase heater burnout
Phase Heater Burnout and 900-TC16NCOMP3 58.40
(open) and heater short-
Heater Short Unit
circuit failure detection
Communications and RS-485 communications and
Second Voltage (SSR) Output a second voltage (SSR) 900-TC16NCOMV2 58.40
Unit output

LOGIC
1-Phase Heater burnout
(open) and heater short-
1-Phase Heater Burnout and
circuit failure detection with 900-TC16P1V2 58.40
second voltage (SSR) output
a second control voltage
(SSR) output
® Enables direct RS-232 connection to personal computer using 900BuilderLite™ software. A Cat. No. 900-CP1X
cable or equivalent is also required.
 Provides two event inputs. Allows selecting up to 4 different pre-configured set points, controller Run/Stop or
Auto/Manual mode, from 2 external inputs.
 Heater burnout is not available for 0...20 or 4…20 mA analog output style 900-TC16 controllers such as the 900-
TC16AC.
 To obtain 38.4 k baud rate, Series B communiation units must be used with any 900-TC8x controller catalog
number from the Product Selection table on the previous page.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-41


Bulletin 900-TC
Temperature Controllers
Accessories
Current Transformer (Use with Bulletins 900-TC8 and 900-TC16 Only for Heater Burnout)
For Use With Hole Diameter 1 Cat. No.
5.8 dia. 900-CT1 37.10
900-TC8, 900-TC16
12.0 dia. 900-CT2 53.00
1 The hole diameter is the only functional difference between the Cat. No. 900-CT1 and the Cat. No. 900-CT2.
Current output to controller is the same.

900BuilderLite™ Personal Computer Configuration Software


(For Enhanced Functionality of 900-TC8 and 900-TC16 Controllers)
Free software. Allows online configuration and monitoring (direct or network) plus program
upload/download capability to/from PC disk media for any enhanced 900-TC8 or 900-TC16
controller.

Note: To obtain the free software, go to http://www.ab.com and use the A-Z Product Directory under
"Resources" to locate the Temperature Controller home page. With the Bulletin 900-TC Single-Loop
website displayed, go to the "Get Software" selection in the upper right and click on 900BuilderLite.
Follow the download instructions.
Accessory Cat. No.
Free configuration software for Enhanced Functionality Bulletin 900-TC8 and 900-TC16
900-BLDLTSW1
controllers.

900Builder Personal Computer Configuration Software


Allows graphical configuration and monitoring of controller parameters with data-logging and
LOGIC

trending, plus program upload/download capability for any Bulletin 900-TCx controller.
Accessory Cat. No.
900Builder™ Personal Computer Configuration Software for Bulletin
900-BLDSW1 133.00
900-TC32 Temperature Controllers (available in CD format only)

USB Direct Communication Cable


This cable allows direct 1-to-1 (no network capability) communication between a PC USB port and
the serial port of a Bulletin 900-TC16 or a 900-TC8 controller. No communication option unit is
required. The cable can be used with the 900BuilderLite™ software to modify parameters, monitor
controller operation, and upload or download parameters to/from PC disk media.
Accessory Cat. No.
USB-Serial Conversion Cable 900-CPOEM1 308.00

Interface Converter (RS-232/USB to RS-485) Model


Converts personal computer RS-232 or USB (Ser. B or later) communications to RS-485. Use for
interface with up to 31 units of controllers type 900-TC8 or 900-TC16 with communication option
board or 900-TC32Cxx.
Bulletin Size Power Supply Voltage Cat. No.
30 mm (W) x 80 mm 100…240V AC 900-CONVZ25 361.00
900-CONV
(H) x 78 mm (D) 24V AC/DC 900-CONVU25 361.00

RS-232 Interface Cable


Allows connection between a 900-TC8 with a 900-TC8232 option unit and a PC using 900Builder
software or PC with 900Builder and a 900-CONV RS232-to-RS485 converter.
Accessory Cat. No.
RS-232 cable with 9-pin female D shell and 3 flying leads (3 m) 900-CP1X 58.40

2-42 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-RCD, 1492-SP, 1492-FB, 1489, 140F
Circuit Protection
Product Line Overview
Device Selection

Bulletin 1492-RCD 1492-SP


Type Residual Current Device Miniature Circuit Breaker
 True IP2X finger-safe design (front)
 Energy Limiting Design protects
 True IP2X finger-safe design (front)
downstream components better than
 For applications in which AC and
conventional breakers during short
pulsating DC fault currents are likely to
circuits
appear, nonselective and non-delayed
 Field mountable options for selective
Features  Designed to prevent unwanted tripping
applications
caused by switching electronic circuit
 AC and DC voltage ratings in one
devices
convenient device
 Auxiliary and Signal contacts may be
 Superior shock and vibration resistance
added
capabilities
 Mounts on hut (DIN) rail
2 pole (1 + N) 1, 2, 3 pole
Number of Poles
4 pole (3 + N) 1 pole + neutral, 3 pole + neutral

LOGIC
Rated voltage 230V AC (1+N), 400V AC (3+N) 230/400V AC, 240/415V AC
Tripping characteristic
— 30 °C
reference temperature
Rated tripping current 30, 100, 300, 500 mA —
Sensitivity AC and pulsating DC —
10 kA with 63 A gG/gL back-up fuse
Rated short circuit for up to 63 A
10 kA
capability 10 kA with 80 A gG/gL back-up fuse
for 80 A
Max. back-up fuse for 63 A gG/gL for up to 63 A
100 A gG/gL
short circuit protection 80 A gG/gL for 80 A
25 A gG/gL (25 A and 40 A devices)
Maximum back-up fuse
40 A gG/gL (63 A devices) —
for overload protection
50 A gG/gL (80 A devices)
Degree of protection IP20 IP20
Mechanical life ≥10000 changeovers ≥6000 changeovers
Mounting 35 mm hut (DIN) rail 35 mm hut (DIN) rail
-5°C…+40°C
Operating temperature -5°C…+40°C (reduction factors are required
for higher temperatures )
Wire size 1.5…35 mm2 1…25 mm2
Terminal torque 2.4 N.m ≤40 A, 3.0 N.m ≥63 A 2.4 N.m
Standards and IEC/EN 61008 IEC/EN 60889
Approvals VDE, CE CE, VDE, UL 1077, CSA 22.2 No. 235
Product Selection Page 2-68 Page 2-70

Rockwell Automation Visit our website: www.ab.com/catalogs 2-65


Bulletin 1492-RCD, 1492-SP, 1492-FB, 1489, 140F
Circuit Protection
Product Line Overview
Device Selection

Bulletin 1489 1492-FB


For Class For Midget
480Y/277V AC 240V AC For Class J Fuse
Type CC Fuse Fuse
0.5…25 A 0.5…40 A 30 A 30 A 60 A 30 A
 True IP2X finger-safe design  EN/IEC 60529 Front Finger Protection — Dead
(front) front construction
 10,000 A interrupt  Handle isolates the fuse from line power when it
 A postively trip-free is opened for fuse insertion or removal
mechanism (breaker operation  Compact size requireing less panel space than
cannot be defeated by holding open style fuse folders
the handle in the ON position)  Optional blown fuse indicators - allow for easy
Features  Superior shock and vibration troubleshooting of electrical circuits
resistance capabilties  Type M holder - accepts 0…30 A midget fuses (1
 Mounts on DIN Rail 1/2" x 13/32")
 IEC 60947-2  Type C holder - accepts 0…30 A Class CC fuses)
- 0.5...40 A @ 240, 415V AC  Type J 30 & 60 A holders - accepts Class J fuses
- 15,000 A interrupting  Silver-plated fuse clips
LOGIC

 Field-mountable options  Mounts on DIN rail, marker-ready and increased


 Optional terminal for ring lugs heat dissipation
UL 489 Listed (CSA C22.2 No.
Certifications 5.1), UL File Number E197878 CE, ULus, CSA CE, URus, CSA
VDE (SEC 60 947-2)
Maximum Voltage Rating 480Y/277V AC 600V AC/DC
25 G Half Sine Wave for 11 ms
Shock 25 G Half Sine Wave for 11 ms (Three Axes)
(Three Axes)
Tripping Characteristic 40°C (UL/CSA)
NA
Reference Temperature 30°C (IEC)
C Curve: 5…10
Tripping Characteristic NA
D Curve: 10…20
100...500 Hz for 1 hour
5 G peak or 0.030 "peak-to-peak" displacement for
Amplitude — 10...57 Hz; 0.030
Vibration 2 hours in each perpendicular direction. Vibration
inches peak to peak; 57...500
sweep 10 to 2000 to 10 Hz (15 minutes long)
Hz; 5 G peak
-13...140°F (-25...+55°C),
Operating Temperature -4...130°F (–20…+55°C)
non-condensing
Housing Material Nylon Nylon
110…600V 110…600V
Working AC/DC or AC/DC or
— 110…600V AC/DC
Voltage 12…72V 12…72V
AC/DC AC/DC
With Leakage
LED — 2.0 mA
Indicator Current
#16…4 AWG #14…1 #10…1 #16…4 AWG
Wire Size 0.8...13 mm2/#18...6 AWG Cu
Cu AWG Cu AWG Cu Cu
10 kA @ 240V AC and
Interrupt Rating 200 kA 50 kA
480Y/277V AC (UL/CSA)
Product Selection Page 2-76 Page 2-77

2-66 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-RCD, 1492-SP, 1492-FB, 1489, 140F
Circuit Protection
Product Line Overview
Device Selection

Bulletin 140F
Type MCS Fuse Holders
 Available for UL Class CC or Midget Fuses, with or without blown fuse indication
 Lockable in the open position
 Compatible with 140M accessories
Features  Compact busbar and connectors of contactors 100C and 100M
 1 NO/ 1 NC Auxiliary Contact, early break NC
 Provides capability for dropping out contactor before breaking current on fuse
 Late make NO provides positive indication that power circuit is open
Product Selection Page 2-78

LOGIC

Rockwell Automation Visit our website: www.ab.com/catalogs 2-67


Bulletin 1492-RCD
Residual Current Devices
Product Overview
Residual Current Devices Bulletin 1492-RCD
Earth Leakage Detectors for IEC Applications

The Bulletin 1492-RCD line includes Residual


Current Devices for earth leakage detection to IEC
standards. These devices are used in association
with miniature circuit breakers (1492-SP).

1492-RCD2 1492-RCD4
 True IP2X finger-safe design (front)
 Undelayed tripping time
 Line-voltage independent tripping (suitable for residual current & additional protection)
 Rated tripping current: 30, 100, 300, 500 mA
 For applications in which AC and pulsating DC fault currents are likely to appear, nonselective and
non-delayed
 Designed to prevent unwanted tripping caused by switching electronic circuit devices
 Mounts on DIN Rail
 Busbar position on top or bottom
 Conditionally surge current proof 250 A
 Rated Short-Circuit strength: 10 kA with 63 A gG/gL back-up fuse, 10 kA with 80 A gG/
gL back-up fuse for 80 A device
LOGIC

Standard Versions
Operating Rated Rated
Voltage, Tripping Operational
Nominal Current Current 2 poles (1 pole + neutral) 4 poles (3 poles + neutral)
[V] [mA] [A] Cat. No. Cat. No.
16 1492-RCD2A16 86.20 — —
25 1492-RCD2A25 71.50 1492-RCD4A25 94.90
30 40 1492-RCD2A40 89.80 1492-RCD4A40 117.00
63 — — 1492-RCD4A63 170.00
80 — — 1492-RCD4A80 266.00
25 1492-RCD2B25 74.10 1492-RCD4B25 97.70
100 40 1492-RCD2B40 92.50 1492-RCD4B40 122.00
63 — — 1492-RCD4B63 176.00
230/400V 16 — — 1492-RCD4C16 102.00
50 Hz 25 1492-RCD2C25 64.70 1492-RCD4C25 85.30
300 40 1492-RCD2C40 80.90 1492-RCD4C40 107.00
63 — — 1492-RCD4C63 153.00
80 — — 1492-RCD4C80 239.00
16 — — 1492-RCD4D16 96.70
25 — — 1492-RCD4D25 80.60
500 40 — — 1492-RCD4D40 101.00
63 — — 1492-RCD4D63 145.00
80 — — 1492-RCD4D80 226.00

2-68 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-RCD
Residual Current Devices
Product Selection / Accessories
Versions for Use with Variable Frequency Drives
Operating Voltage, Rated Operational
Nominal Rated Tripping Current Current 4 poles (3 poles + neutral)
[V] [mA] [A] Cat. No.
40 1492-RCD4B40D 157.00
100
63 1492-RCD4B63D 211.00
230/400V 50 Hz
40 1492-RCD4C40D 142.00
300
63 1492-RCD4C63D 188.00

Accessories 1492-RCD
Description Diagram Cat. No.

Dual Auxiliary Contact Module 12 14 22 24


Switches when protective device is operated
1492-ASPHH3 25.30
manually or tripped electrically 11 21

2 N.O. – 2 N.C. 2 Form C Contact

LOGIC
Auxiliary/Signal Alarm Contact Module
1 Auxiliary Contact switches when protective device
is operated manually or tripped electrically 96 98 12 14

1 N.O. – 1 N.C. Form C Contact 1492-ASPHS3 28.00


95 11
1 Signal Contact switches when protective device is
tripped electrically
1 N.O. – 1 N.C. Form C Contact

Rockwell Automation Visit our website: www.ab.com/catalogs 2-69


Bulletin 1492-SP
Miniature Circuit Breakers
Product Selection
Miniature Circuit Breakers Bulletin 1492-SP

1492-SP1 1492-SP2 1492-SP3 1492-SP1...-N 1492-SP3...-N

 Energy Limiting Design - Protects Downstream Components Better than Conventional Breakers
During Short Circuits
 Field Mountable Options for Selective Applications
 IP2x Finger-Protection (Front)
 International Approvals - CE Marked, and Meets UL, CSA, and IEC (VDE, GL) Standards for
Worldwide Acceptance
 Ratings to 480Y/277V AC @ 240/415V AC - 10 000 A Interrupt Rating
 AC and DC Voltage Ratings - in One Convenient Device
 A Positively Trip-Free Mechanism (Breaker Operation Cannot be Defeated by Holding the Handle in
the ON Position)
 3 Trip Curves: B, C, and D
 Time Delay (D Characteristic) for High Inrush Currents During Inductive Start-Ups Such as
LOGIC

Transformers and Power Supplies


 Superior Shock and Vibration Resistance Capabilities — Helps to Prevent Nuisance Tripping
 Mounts on DIN Rail

Miniature Circuit Breakers, 1-Pole


Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP1C010 13.50 1492-SP1D010 17.20
2 1492-SP1C020 13.50 1492-SP1D020 17.20
4 1492-SP1C040 13.50 1492-SP1D040 17.20
6 1492-SP1C060 8.34 1492-SP1D060 10.60
10 1492-SP1C100 8.34 1492-SP1D100 10.60
13 1492-SP1C130 8.34 1492-SP1D130 10.60
16 1492-SP1C160 8.34 1492-SP1D160 10.60
20 1492-SP1C200 9.37 1492-SP1D200 11.80
25 1492-SP1C250 10.20 1492-SP1D250 13.00
32 1492-SP1C320 12.60 1492-SP1D320 15.90
40 1492-SP1C400 15.90 1492-SP1D400 20.10
50 1492-SP1C500 20.90 — —
63 1492-SP1C630 27.50 — —
Package Quantity = 2
For Trip Curves B visit our website or consult your local sales office.

2-70 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-SP
Miniature Circuit Breakers
Product Selection
Miniature Circuit Breakers, 2-Poles
Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP2C010 31.30 1492-SP2D010 39.90
2 1492-SP2C020 31.30 1492-SP2D020 39.90
4 1492-SP2C040 31.30 1492-SP2D040 39.90
6 1492-SP2C060 19.40 1492-SP2D060 24.60
10 1492-SP2C100 19.40 1492-SP2D100 24.60
13 1492-SP2C130 19.40 1492-SP2D130 24.60
16 1492-SP2C160 19.40 1492-SP2D160 24.60
20 1492-SP2C200 21.60 1492-SP2D200 27.50
25 1492-SP2C250 23.60 1492-SP2D250 30.00
32 1492-SP2C320 29.00 1492-SP2D320 36.90
40 1492-SP2C400 36.80 1492-SP2D400 46.70
50 1492-SP2C500 48.40 — —
63 1492-SP2C630 63.90 — —
For Trip Curves B visit our website or consult your local sales office.

LOGIC
Miniature Circuit Breakers, 3-Poles
Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP3C010 50.10 1492-SP3D010 63.60
2 1492-SP3C020 50.10 1492-SP3D020 63.60
4 1492-SP3C040 50.10 1492-SP3D040 63.60
6 1492-SP3C060 30.90 1492-SP3D060 39.20
10 1492-SP3C100 30.90 1492-SP3D100 39.20
13 1492-SP3C130 30.90 1492-SP3D130 39.20
16 1492-SP3C160 30.90 1492-SP3D160 39.20
20 1492-SP3C200 34.60 1492-SP3D200 43.90
25 1492-SP3C250 37.70 1492-SP3D250 47.80
32 1492-SP3C320 46.40 1492-SP3D320 74.50
40 1492-SP3C400 58.60 1492-SP3D400 74.50
50 1492-SP3C500 77.10 — —
63 1492-SP3C630 102.00 — —
For Trip Curves B visit our website or consult your local sales office.

Rockwell Automation Visit our website: www.ab.com/catalogs 2-71


Bulletin 1492-SP
Miniature Circuit Breakers
Product Selection
Miniature Circuit Breakers, 1-Pole + Neutral Module
Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP1C010-N 23.70 1492-SP1D010-N 30.10
2 1492-SP1C020-N 23.70 1492-SP1D020-N 30.10
4 1492-SP1C040-N 23.70 1492-SP1D040-N 30.10
6 1492-SP1C060-N 14.60 1492-SP1D060-N 18.50
10 1492-SP1C100-N 14.60 1492-SP1D100-N 18.50
2 N 13 1492-SP1C130-N 14.60 1492-SP1D130-N 18.50
16 1492-SP1C160-N 14.60 1492-SP1D160-N 18.50
1 N 20 1492-SP1C200-N 16.40 1492-SP1D200-N 20.80
25 1492-SP1C250-N 17.80 1492-SP1D250-N 22.70
32 1492-SP1C320-N 21.90 1492-SP1D320-N 27.80
40 1492-SP1C400-N 27.70 1492-SP1D400-N 35.20
50 1492-SP1C500-N 36.50 — —
63 1492-SP1C630-N 48.20 — —
For Trip Curves B visit our website or consult your local sales office.
LOGIC

Miniature Circuit Breakers, 3-Poles + Neutral Module


Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP3C010-N 60.20 1492-SP3D010-N 76.40
2 1492-SP3C020-N 60.20 1492-SP3D020-N 76.40
4 1492-SP3C040-N 60.20 1492-SP3D040-N 76.40
6 1492-SP3C060-N 37.10 1492-SP3D060-N 47.20
10 1492-SP3C100-N 37.10 1492-SP3D100-N 47.20
2 4 6 N 13 1492-SP3C130-N 37.10 1492-SP3D130-N 47.20
16 1492-SP3C160-N 37.10 1492-SP3D160-N 47.20
1 3 5 N
20 1492-SP3C200-N 41.60 1492-SP3D200-N 52.80
25 1492-SP3C250-N 45.30 1492-SP3D250-N 57.50
32 1492-SP3C320-N 55.70 1492-SP3D320-N 70.80
40 1492-SP3C400-N 70.60 1492-SP3D400-N 89.60
50 1492-SP3C500-N 92.80 — —
63 1492-SP3C630-N 123.00 — —
For Trip Curves B visit our website or consult your local sales office.

2-72 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-SP
Miniature Circuit Breakers
Accessories

Description Diagram PQ Cat. No.


Auxiliary Contact Module
12 14
Switches when protective device is
operated manually or tripped 1 1492-ASPH3 13.40
electrically 11
1 N.O. – 1 N.C. Form C Contact
Dual Auxiliary Contact Module
12 14 22 24
Switches when protective device is
operated manually or tripped 1 1492-ASPHH3 25.30
electrically 11 21
2 N.O. – 2 N.C. 2 Form C Contact
Auxiliary/Signal Alarm Contact
Module
1 Auxiliary Contact switches when
protective device is operated 96 98 12 14
manually or tripped electrically
1 1492-ASPHS3 28.00
1 N.O. – 1 N.C. Form C Contact 95 11
1 Signal Contact switches when
protective device is tripped
electrically
1 N.O. – 1 N.C. Form C Contact
Undervoltage Release Module 50…115V
1 1492-ASPU115 81.80
Use the undervoltage release module AC
to trip the adjacent breaker poles D1
when the applied voltage is less than
the nominal voltage. U<
Undervoltage trip is often used when 110…240V
1 1492-ASPU230 81.80

LOGIC
loss of power and eventual D2 AC
restoration of power creates an
unsafe or unknown set of condition.
Shunt Trip Module 110…415V
Use the shunt trip module to trip the AC
1 1492-ASPA1 21.90
adjacent breaker poles from a remote (110…230V
location. DC)
The module is actuated by applying a
voltage (pickup voltage) to the trip
terminals. 12…110V
Shunt trip modules are often used in AC
1 1492-ASPA2 21.90
emergency shutdown circuits where (12…60V
multiple power circuits must be DC)
switched off from a single location.
Mounting Rails
DIN (#3) Symmetrical Rail
10 199-DR1 13.30
35 mm x 7.5 mm x 1 m long
Order must be for 10 rails or multiples of 10.
DIN Hi-Rise Symmetrical Rail, 1 m
35 mm x 7.5 mm, 57.4 mm (2.26 in.) high 2 1492-DR6 19.10
Copper-Free Aluminum
DIN Angled Hi-Rise Symmetrical Rail, 1 m
35 mm x 7.5 mm, 71.0 mm (2.80 in.) high 2 1492-DR7 22.20
Zinc-Plated, Chromated Steel
End Anchor 10 1492-EAH35 2.39
Lockout Attachment 10 1492-ASPLOA 4.14
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-73


Bulletin 1492-SP
Miniature Circuit Breakers
Accessories

No. of Rated Operational


Description 1492-SP Current (Ie) [A] PQ Cat. No.
Incoming Terminals for fork style commoning links, IP20 protection
(Not for use in North American installations)
For max 25 mm2 wire 1 1492-ASPCLT25 2.39
For max 35 mm2 wire 1 1492-ASPCLT35 4.67
Fork Style Commoning Links
for 1492-SP without Auxiliary Contact Module (may not be cut)
1 pole 2 63 1 1492-ASPCL102 1.46

1 pole 6 63 1 1492-ASPCL106 2.22

1 pole 12 63 1 1492-ASPCL112 3.49

2 poles (1p + N) 2 63 1 1492-ASPCL204 2.66

2 poles (1p + N) 3 63 1 1492-ASPCL206 4.72

2 poles (1p + N) 6 63 1 1492-ASPCL212 7.75

3 poles 2 63 1 1492-ASPCL306 4.35

3 poles 4 63 1 1492-ASPCL312 6.68


LOGIC

4 poles 2 63 1 1492-ASPCL408 8.49

4 poles 3 63 1 1492-ASPCL412 12.20

Fork Style Commoning Links


for 1492-SP with an Auxiliary Contact Module or Auxiliary/Signal Alarm Contact Module
1 pole 2 63 20 1492-ASPCL1A02 1.80

1 pole 6 63 20 1492-ASPCL1A06 3.82

1 pole 9 63 20 1492-ASPCL1A09 5.57

2 poles (1p + N) 2 63 10 1492-ASPCL2A04 3.61

2 poles (1p + N) 3 63 10 1492-ASPCL2A06 8.27

2 poles (1p + N) 5 63 10 1492-ASPCL2A10 8.27

3 poles 2 63 10 1492-ASPCL3A06 5.73

3 poles 4 63 10 1492-ASPCL3A12 10.50

PQ = Package Quantity

2-74 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-SP
Miniature Circuit Breakers
Accessories

No. of Rated Operational


Description 1492-SP Current (Ie) [A] PQ Cat. No.
Fork Style Commoning Links
for multiple single pole 1492-SP, each with 1 Auxiliary Contact or 1 Auxiliary/Signal Alarm Contact Module
2x3 (1p) 63 10 1492-ASPCL3AP06 6.10
2x3 (1p)+2
63 10 1492-ASPCL3AP08 8.70
(1p)

3x3 (1p) 63 10 1492-ASPCL3AP09 9.76

Protective cover
5 1492-ASPCLPS 2.46
for unused fork termination

Fork Style Commoning Links


(may be cut to length, not for use with accessories)
1 m (56
1 pole 63 1 1492-ASPCL1 19.20
devices/m)

1 m (19
3 poles 63 1 1492-ASPCL3 35.10
devices/m)

End Cap (for 1 and 3 poles) 10 1492-ASPEC1 0.79

Pin Style Commoning Links

LOGIC
(may be cut to length, not for use with accessories)
1 m (56
1 pole 40 1 1492-ACBCL1 25.10
devices/m)
2 poles (1p + 1 m (26
30 1 1492-ACBCL2 47.10
N) devices/m)
1 m (16
3 poles 30 1 1492-ACBCL3 53.40
devices/m)

End Cap (for 2 and 3 poles) 10 1492-ACBEC1 0.47

PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-75


Bulletin 1489
DIN Rail Mounting Fuse Holders
Product Selection
Miniature Circuit Breakers Bulletin 1489
 IP2x Finger-Protection (Front)
 North America certifications: UL 489, CSA 22.2 No. 5.1
 International standards: CE Marked, and IEC (VDE) standards for
worldwide acceptance
 Ratings: UL/CSA — max. 480Y/277V AC – 10,000 A interrupt rating;
IEC — max. 240/415V AC – 15,000 A interrupt rating
 Trip curves: C and D
 Time delay (D Characteristic) for high inrush currents during inductive
start-ups Such as motors, transformers and power supplies
 Mounts on Standard 35 mm DIN Rail (A-B p/n 199-DR1)

Miniature Circuit Breakers, 1-Pole


Trip Curve C
No. of Poles Rated Current UL/CSA Max. Volt. Cat. No.
2 1489-A1C020 30.30 T1S
4 1489-A1C040 30.30 T1S
1-Pole 6 480Y/277V AC 48V DC 1489-A1C060 30.30 T1S
LOGIC

10 1489-A1C100 30.30 T1S


161 1489-A1C160 30.30 T1S
1 Common IEC current rating.

2-76 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1492-FB
DIN Rail Mounting Fuse Holders
Product Selection
DIN Rail Mounting Fuse Holders 1492-FB
 EN/IEC 60529 Finger Protection — Dead Front Construction
 The Patented Handle Design Isolates the Fuse from Power When
Handle is Opened for Fuse Insertion or Removal
 Optional Blown Fuse LED Indicator — Allow for Easy
Troubleshooting of Electrical Circuits
 Easy Insertion/Removal of Fuses, No Special Tools Required
 Mounts on Standard 35 mm DIN Rail (A-B p/n 199-DR1)
DIN Rail Mounting Fuse Holders for Class CC / Midget Fuse
For Class CC Fuse For Midget Fuse
30 A 1 30 A
PQ Cat. No. Cat. No.
1 Pole Fuse Block 6 1492-FB1C30 10.70 1492-FB1M30 10.80
1 Pole Fuse Block with
6 1492-FB1C30-L 15.90 1492-FB1M30-L 15.90
Indication
1-Pole 1 Pole Fuse Block with
6 1492-FB1C30-D1 15.90 1492-FB1M30-D1 15.90
Indication, 12-72V
With Blown Fuse Indicator
6 1492-FB1C30-D2 15.90 1492-FB1M30-D2 15.90
(LED) 48V DC
2 Pole Fuse Block 3 1492-FB2C30 22.20 1492-FB2M30 22.60
2-
Poles 2 Pole Fuse Block with 3 1492-FB2C30-L 32.90 1492-FB2M30-L 32.90
Indication

LOGIC
3 Pole Fuse Block 2 1492-FB3C30 34.10 1492-FB3M30 33.00
3-
Poles 3 Pole Fuse Block with 2 1492-FB3C30-L 49.90 1492-FB3M30-L 49.30
Indication
1 All major fuse brands and current ranges have been evaluated for this fuse holder. Due to the heat they generate,
the following fuses must be derated:
Ferraz Shamut ATQR 1.25 I = 0.42 A max.
Ferraz Shamut ATQR 1.40 I = 0.47 A max.
PQ = Package Quantity

DIN Rail Mounting Fuse Holders for Class J Fuse


For Class J Fuse
30 A 60 A
PQ Cat. No. Cat. No.
1 Pole Fuse Block, Type J 30 A 6 1492-FB1J30 22.00 1492-FB1J60 25.20
1-Pole 1 Pole Fuse Block with
6 1492-FB1J30-L 25.80 1492-FB1J60-L 28.50
Indication
2 Pole Fuse Block 3 1492-FB2J30 45.70 1492-FB2J60 51.90
2-
Poles 2 Pole Fuse Block with 3 1492-FB2J30-L 52.90 1492-FB2J60-L 58.90
Indication
3 Pole Fuse Block 2 1492-FB3J30 68.80 1492-FB3J60 77.80
3-
Poles 3 Pole Fuse Block with 2 1492-FB3J30-L 79.30 1492-FB3J60-L 88.30
Indication
PQ = Package Quantity

Rockwell Automation Visit our website: www.ab.com/catalogs 2-77


Bulletin 140F
MCS Fuse Holders
Product Selection
MCS Fuse Holders 140F

 Available for UL Class CC or Midget Fuses and IEC 10 x 38 mm fuses,


with or without blown fuse indication
 Lockable in the open position
 Compatible with 140M accessories
 Compact busbar and connectors of contactors 100C and 100M
 1 NO/ 1 NC Auxiliary Contact, early break NC
 Provides capability for dropping out contactor before breaking current
on fuse
 Late make NO provides positive indication that power circuit is open

Approvals
Description IEC CE Mark UL CSA Cat. No.
MCS Fuse Holder, CC - 30A Yes Yes Yes Yes 140F-D3C-C30 40.10
MCS Fuse Holder with Blown Fuse
Yes Yes Yes Yes 140F-D3C-C30L 56.30
Indication, CC - 30A
MCS Fuse Holder, Midget - 30A Yes Yes Yes Yes 140F-D3M-C30 40.10
MCS Fuse Holder with Blown Fuse
Yes Yes Yes Yes 140F-D3M-C30L 56.30
Indication, Midget - 30A
LOGIC

MCS Fuse Holder, gG - 32A Yes Yes No No 140F-D3F-C30 37.90


MCS Fuse Holder with Blown Fuse
Yes Yes No No 140F-D3F-C30L 54.20
Indication, gG - 32A
Auxiliary Contact for MCS Fuse
Holder (1 NO Late Make + 1 NC Yes Yes Yes Yes 140F-C-AFA11 7.78
Early Break)

For additional accessories refer to contactors 100M/100-C and circuit breakers 140M.

2-78 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1606, 1609, 1497
Power Supplies, Control Circuit Transformers
Product Line Overview
Switched Mode Power Supplies 1606

Bulletin 1606-XLP 1606-XL 1606-XL


Type Single Phase Single Phase Three Phase
 Low inrush current
 Low inrush current
 PFC Choke
 Low inrush current  PFC Choke
 Wide range input; auto
 Wide range input; auto  Wide range input; auto
select input
select input select input
 Superior overload design
 Superior overload design  Superior overload design
(continuous current, no
(continuous current, no (continuous current, no
Features hiccup)
hiccup) hiccup)
 NEC Class 2 “Limited
 NEC Class 2 “Limited  Selectable operating
Power“ Option
Power“ option mode (single/parallel)
 Selectable operating
 Superior efficiency and  Superior efficiency and
mode (single/parallel)
temperature rating temperature rating
 Superior efficiency and
 Output signals
temperature rating
Output Power 25…100 W 60...480 W 120...960 W
85…264V AC 85…132/176…264V AC 340…576V AC

LOGIC
Input Voltage
85…375V DC 160...375V DC 450...820V DC
Efficiency 80...90% 87...93% 89...92.5%
5, 10...12, 12, 15, 24, 48V
Output Voltage 12, 24, 36, 48V DC 24, 48V DC
DC
Rated Output Current 1.3…4.2 A 2.5…20 A 4…40 A
Operating Temperature -10…+70°C -10…+70°C -10…+70°C
Range (Tamb) >60°C with derating >60°C with derating >60°C with derating
CE, UL508, UL1950, CE, UL508, UL1950, CE, UL508, UL1950,
Approvals IEC/EN IEC/EN IEC/EN
60950, EMC 60950, EN 50178, EMC 60950, EN 50178, EMC
EN 55011 (Class B), EN 55011 (Class B),
EN 50081-1, EN 55022 (Class B), EN 55022 (Class B),
Standards EN 61000-6-2, EN 61000-6-2, EN 61000-6-2,
EN 61000-3-2 (A14) EN 61000-3-2 (A14), EN 61000-3-2 (A14),
EN 50081-1 EN 50081-1
Product Selection Page 2-81 Page 2-81 Page 2-82

Rockwell Automation Visit our website: www.ab.com/catalogs 2-79


Bulletin 1606, 1609, 1497
Power Supplies, Control Circuit Transformers
Product Line Overview
Switched Mode Power Supplies 1606, Control Circuit Transformer 1497

Bulletin 1606-XLS 1609 1497


Uninterruptible Power Control Circuit
Type Single/Three Phase
Supply Transformer
 Ultra-small size  Rugged industrial design  Wide VA range
 Extra-low inrush current  DIN Rail or Back of Panel  Enclosed construction
 Active Power Factor mountable 63...350 VA
Correction  Elevated temperature  Terminal covers finger
 Wide range AC/DC input; performance (up to 50°C) safe
auto select input  Comprehensive network  Optional fuse covers
Features
 Superior reserve power management available
(can support 150% rated  Remote  Dual primary and
power for 3...5 seconds) monitoring/configuration secondary fuse block
 Superior efficiency and  "Dry contact" I/O available to 500 VA
temperature rating  Line interactive  Class B insulation (130°C)
 DC OK and Overload LED  Pure sine wave output  All welded construction
Output Power 120...480 W 325 W/500 VA 63..2000 VA
85…276/ 323…552V AC
Input Voltage 120, 208/230V AC 208…600V
LOGIC

88…375/ 450…780V DC
Efficiency 91.6...95% 96% ⎯
24…120V
Output Voltage 24V DC 120, 208/230V AC
Multi-tap 115…230V (50 Hz)
Rated Output Current 5…20 A 4.2 A ⎯
Operating Temperature -25…+70°C
0…50°C ⎯
Range (Tamb) >60°C with derating
CE, UL508, UL1950,
CE, UL506, NEC450, TÜV
Approvals IEC/EN UL, CSA, CE
Rheinland
60950, EN 50178, EMC
EN 55011 (Class B),
EN 55022 (Class B),
EN 50091-1-1,
EN 61000-6-2,
EN 50091-2 (Class 2)
Standards EN 61000-3-2 (A14), EN 61558
UL 1778
EN 50081-1
CSA C22.2 No. 107.3
UL 508
UL 1950
Product Selection Page 2-81 Page 2-84 Page 2-86

2-80 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1606
Power Supplies
Product Selection
Power Supplies 1606
 Low inrush current
 PFC choke
 Wide range input; auto select input
 Superior overload design (continuous current, no hiccup)
 NEC Class 2 'Limited Power' option
 Selectable operating mode (single/parallel)
 Superior efficiency and temperature rating

Single Phase Power Supplies


Parallel Meets EN
Operation 61000-3-2
Output Output Output Special (inclined (PFC
Power Voltage Current Features Charact.) Harmonics) Cat. No.
1606-XLP Compact Single Phase
25 W 5…5.5V DC 5.0 A NEC Class 2 — N/A 1606-XLP25A 107.00
10…12V DC 3.0 A NEC Class 2 — N/A 1606-XLP30B 107.00
30 W
24…28V DC 1.3 A NEC Class 2 — N/A 1606-XLP30E 88.60
36 W +/- 12/15V DC 2.8 A Output voltage — N/A 1606-XLP36C 115.00
adjustable
12…15V DC 4.2 A NEC Class 2 — N/A 1606-XLP50B 131.00
24…28V DC 2.1 A NEC Class 2 — N/A 1606-XLP50E 106.00

LOGIC
50 W
24…28V DC 2.1 A NEC Class 2 — N/A 1606-XLP50EZ 111.00
48…56V DC 1.0 A NEC Class 2 — N/A 1606-XLP50F 115.00
72 W 24…28V DC 3.0 A NEC Class 2 — N/A 1606-XLP72E 133.00
90 W 12…15V DC 8.0 A NEC Class 2 Yes Yes 1606-XLP90B 201.00
24…28V DC 4.2 A Yes 1 Yes 1606-XLP100E 156.00
100 W
48…56V DC 2.1 A Yes 1 Yes 1606-XLP100F 175.00
1606-XL Standard Single Phase
60 W 2.5 A NEC Class 2 — Yes 1606-XL60D 151.00
24V DC
120 W 5.0 A — — Yes 1606-XL120D 202.00
180 W 12…15V DC 15 A — — No 1606-XL180B 329.00
FM Class 1 — No 1606-XL240E 264.00
24…28V DC 10 A
240 W Div. 2 T3A — Yes 1606-XL240EP 303.00
48…56V DC 5.0 A — — Yes 1606-XL240FP 343.00
Active inrush
Yes 1 No 1606-XL480E 345.00
current limiting
24…28V DC 20 A — Yes 1 Yes 1606-XL480EP 424.00
480 W Remote shut
Yes 1 Yes 1606-XL480EPT 467.00
down
36…43V DC 13.3 A — Yes 1 Yes 1606-XL480GP 467.00
48…56V DC 10 A — Yes 1 No 1606-XL480F 444.00
1606-XLS Performance Single Phase
120 W 24…28V DC 5.0 A — Yes Yes 1606-XLS120E 212.00
240 W 24…28V DC 10 A — Yes Yes 1606-XLS240E 277.00
1 Single/parallel operation (inclined characteristic) selectable (jumper)

Rockwell Automation Visit our website: www.ab.com/catalogs 2-81


Bulletin 1606
Power Supplies
Product Selection
Power Supplies 1606, continued

Three Phase Power Supplies


Parallel Meets EN
Operation 61000-3-2
Output Output Output Special (inclined (PFC
Power Voltage Current Features Characteristics) Harmonics) Cat. No.
1606-XL Standard Three Phase
120 W 5.0 A — — Yes 1606-XL120E-3 235.00
Overload
behavior
selectable
LOGIC

(FUSE
240 W 10 A Yes 1 Yes 1606-XL240E-3 264.00
Mode/continuou
s current), 2-
phase operation
24…28V admissible
DC
20 A — Yes 1 Yes 1606-XL480E-3 305.00
Wide input
range; overload
behavior
20 A selectable Yes 1 Yes 1606-XL480E-3W 312.00
480 W
(FUSE
Mode/continuou
s current)
48…56V Input voltage
10 A Yes 1 Yes 1606-XL480F-3H 377.00
DC 400V AC
720 W 30 A — Yes 1 Yes 1606-XL720E-3 426.00
Passive load
40 A Yes 1 Yes 1606-XL960E-3 478.00
24…28V sharing
960 W DC Active inrush
Active current
40 A current limiting; Yes 1606-XL960E-3S 565.00
sharing
output signals
1606-XLS Performance Three Phase
24…28V
480 W 20 A — Yes Yes 1606-XLS480E-3 328.00
DC
1 Single/parallel operation (inclined characteristic) selectable (jumper)

2-82 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1606
Power Supplies
Product Selection
Power Supplies 1606, continued
Parallel Meets EN
Operation 61000-3-2
Output Output Output Special (inclined (PFC
Power Voltage Current Features Characteristics) Harmonics) Cat. No.
1606-XL Special Modules
23…27.8 Brownout buffer
— 20 A — N/A 1606-XLBUFFER 252.00
V DC module
DC/DC
40 W 5.1V DC 8.0 A — No 1606-XLDC40A 224.00
converter
Electronically
96 W 24V DC 4.0 A — Yes 1606-XLDNET4 267.00
limited 4 A
Electronically
91 W 24V DC 3.8 A Yes 1606-XLSDNET4 267.00
limited 3.8 A
Electronically
192 W 24V DC 8.0 A — No 1606-XLDNET8 467.00
limited 8 A
Electronically
192 W 24V DC 8.0 A Yes 1606-XLSDNET8 427.00
limited 8 A
60 W 2.5 A N+1 Redundant Yes 1 N/A 1606-XL60DR 191.00
capable , NEC
120 W 24V DC 5.0 A Class 2 ‡ Yes 1 Yes 1606-XL120DR 254.00
N+1 Redundant
240 W 10 A Yes 1 No 1606-XL240DR 324.00
capable ‡
Compact

LOGIC
Vin 1 -.9V
— 16 A Redundancy — N/A 1606-XLPRED 45.30
typ
10-60 V DC 
Vin -.5V Dual 1+1
— 30 A — N/A 1606-XLRED20-30 130.00
typ redundancy 
Vin -.6V Single N+1
— 40 A — N/A 1606-XLRED40 115.00
typ redundancy §
1 Single/parallel operation (inclined characteristic) selectable (jumper)
 To be used alongside 20 and 30 A power supplies (or smaller)
‡ Used with a pair of identical power supplies to offer N+1 redundancy
§ To be used alongside 40 A power supplies (or smaller)

Accessories
Description Cat. No.
Back of panel bracket for XL 1606-XLA 6.18

Rockwell Automation Visit our website: www.ab.com/catalogs 2-83


Bulletin 1609
Power Supplies
Product Selection
Bulletin 1609-U — Industrial Uninterruptible Power Supply

 Rugged Industrial Design


 DIN Rail mountable or Back of Panel mountable
 Elevated Temperature Performance (Up to 50°C)
 Comprehensive Network Management
 Remote Monitoring/Configuration
 "Dry Contact" I/O
 Line Interactive
 Pure Sine Wave Output

Output Operating Without Network Management Card With Network Management Card
Power Input Voltage Temperature Cat. No. Cat. No.
0…40°C 1609-U500NS 565.00 1609-U500NSC 1,110.00
115V AC
500 VA 0…50°C 1609-U500NH 735.00 1609-U500NHC 1,280.00
(325 W) 0…40°C 1609-U500ES 565.00 1609-U500ESC 1,110.00
208/230V AC
0…50°C 1609-U500EH 735.00 1609-U500EHC 1,280.00
LOGIC

Accessories
Description Output Power Cat. No.
40°C Replacement Battery 500 VA (325 W) 1609-500SBAT 100.00
50°C Replacement Battery 500 VA (325 W) 1609-500HBAT 265.00
Network Management Card 1609-NMC 555.00
Remote Start Cable 1609-RSC 37.50

2-84 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1609
Power Supplies
Product Selection
Bulletin 1609-P Series — Industrial Uninterruptible Power Supply

 Rugged Industrial Design


 Tower/Rack Compatible
 Extended Runtime
 Battery Management System
 Hot Swappable Batteries
 Comprehensive Network Management
 Remote Monitoring/Configuration
 Double Conversion Online
 Pure Sine Wave Output
 Frequency and Voltage Regulation
 Automatic Internal Bypass

Output Power Input Voltage Cat. No.


3000 VA (2100 W) 208V AC 1609-P3000H 2,270.00
3000 VA (2100 W) 120V AC 1609-P3000N 2,270.00
3000 VA (2100 W) 230V AC 1609-P3000A 2,270.00

LOGIC
5000 VA (3500 W) 208/230V AC 1609-P5000E 6,120.00
8000 VA (6400 W) 208/230V AC 1609-P8000E 8,290.00
10000 VA (8000 W) 208/230V AC 1609-P10000E 10,100.00

Accessories
Description Cat. No.
Network Management Card 1609-NMC 555.00
Remote Start Cable 1609-RSC 37.50
Replacement Battery 1609-PBAT 790.00
External Battery Pack 1609-PXBP 1,160.00
5000 VA CCT 1609-5000CCT 835.00
Rail Kit 1609-PRK1 180.00

Rockwell Automation Visit our website: www.ab.com/catalogs 2-85


Bulletin 1497
Control Circuit Transformers
Product Selection
Control Circuit Transformers 1497
Control Circuit Transformers are designed to reduce supply
voltages to control circuits.
The complete line of transformers is available with optional
factory-installed or panel-mount primary and secondary fuse
block.
A dual primary and secondary fuse block is pre-wired and
mounted on top of the transformer up to 500 VA.
Control Circuit Transformers offer single, dual, and multi-tap
primary voltages.

Primary 220V (50 Hz) / 240V (60 Hz)


Secondary 24V (50 Hz)/24V (60 Hz) Secondary 110V (50 Hz)/120V (60 Hz)
Continuous VA Cat. No. Cat. No.
63 1497-A-AXJK-0-N 37.40 1497-A-AXSX-0-N 37.40
80 1497-B-AXJK-0-N 40.10 1497-B-AXSX-0-N 40.10
130 1497-C-AXJK-0-N 48.10 1497-C-AXSX-0-N 48.10
200 1497-D-AXJK-0-N 58.70 1497-D-AXSX-0-N 58.70
250 1497-E-AXJK-0-N 66.10 1497-E-AXSX-0-N 66.10
350 1497-F-AXJK-0-N 89.50 1497-F-AXSX-0-N 89.50
500 1497-G-AXJK-0-N 122.00 1497-G-AXSX-0-N 122.00
LOGIC

750 1497-H-AXJK-0-N 160.00 1497-H-AXSX-0-N 160.00


800 1497-J-AXJK-0-N 188.00 1497-J-AXSX-0-N 188.00
1000 1497-K-AXJK-0-N 256.00 1497-K-AXSX-0-N 256.00
1600 — — 1497-L-AXSX-0-N 374.00
2000 — — 1497-M-AXSX-0-N 453.00

Primary 220/440V (50 Hz) / 240/480V (60 Hz)


Secondary 24V (50 Hz)/24V (60 Hz) Secondary 110V (50 Hz)/120V (60 Hz)
Continuous VA Cat. No. Cat. No.
63 1497-A-BAJK-0-N 39.20 1497-A-BASX-0-N 39.20
80 1497-B-BAJK-0-N 42.00 1497-B-BASX-0-N 42.00
130 1497-C-BAJK-0-N 50.50 1497-C-BASX-0-N 50.50
200 1497-D-BAJK-0-N 61.70 1497-D-BASX-0-N 61.70
250 1497-E-BAJK-0-N 69.40 1497-E-BASX-0-N 69.40
350 1497-F-BAJK-0-N 93.90 1497-F-BASX-0-N 93.90
500 1497-G-BAJK-0-N 128.00 1497-G-BASX-0-N 128.00
750 1497-H-BAJK-0-N 168.00 1497-H-BASX-0-N 168.00
800 1497-J-BAJK-0-N 198.00 1497-J-BASX-0-N 198.00
1000 1497-K-BAJK-0-N 269.00 1497-K-BASX-0-N 269.00
1600 — — 1497-L-BASX-0-N 392.00
2000 — — 1497-M-BASX-0-N 476.00

2-86 Visit our website: www.ab.com/catalogs Rockwell Automation


Bulletin 1497
Control Circuit Transformers
Product Selection
Primary 380V, 400V, 415V (50 Hz)
Secondary 115V/230V (50 Hz)
Continuous VA Cat. No.
63 1497-A-M4-0-N 44.90
80 1497-B-M4-0-N 48.10
130 1497-C-M4-0-N 57.70
200 1497-D-M4-0-N 70.50
250 1497-E-M4-0-N 79.30
350 1497-F-M4-0-N 107.00
500 1497-G-M4-0-N 146.00
750 1497-H-M4-0-N 192.00
800 1497-J-M4-0-N 227.00
1000 1497-K-M4-0-N 308.00
1600 1497-L-M4-0-N 449.00
2000 1497-M-M4-0-N 544.00

LOGIC
Primary 550V (50 Hz) / 600V (60 Hz)
Secondary 24V (50 Hz)/24V (60 Hz) Secondary 110V (50 Hz)/120V (60 Hz)
Continuous VA Cat. No. Cat. No.
63 1497-A-CXJK-0-N 41.10 1497-A-CXSX-0-N 41.10
80 1497-B-CXJK-0-N 44.10 1497-B-CXSX-0-N 44.10
130 1497-C-CXJK-0-N 52.90 1497-C-CXSX-0-N 52.90
200 1497-D-CXJK-0-N 64.60 1497-D-CXSX-0-N 64.60
250 1497-E-CXJK-0-N 72.70 1497-E-CXSX-0-N 72.70
350 1497-F-CXJK-0-N 98.50 1497-F-CXSX-0-N 98.50
500 1497-G-CXJK-0-N 134.00 1497-G-CXSX-0-N 134.00
750 1497-H-CXJK-0-N 176.00 1497-H-CXSX-0-N 176.00
800 1497-J-CXJK-0-N 207.00 1497-J-CXSX-0-N 207.00
1000 1497-K-CXJK-0-N 282.00 1497-K-CXSX-0-N 282.00
1600 — — 1497-L-CXSX-0-N 411.00
2000 — — 1497-M-CXSX-0-N 499.00

See Publication 1606-SG001_-EN-P for complete product information.